site data - protrak.wilmingtonnc.gov

2
DEWITT ROAD (60' PUBLIC R/W) 63 SECTION 3 FAIRLAWN MB 7, PG 47 61 60 32-A SECTION 3 FAIRLAWN MB 7, PG 47 SECTION 3 FAIRLAWN MB 7, PG 47 SECTION I FAIRLAWN MB 6, PG 6 31 SECTION I FAIRLAWN MB 6, PG 6 25' REAR SETBACK 6 ( NMP 1 : EIP EIP EIPPT IRS (TIE) 1 ( 30.00' 1 ( 29.99' (TIE) 1 : 357.51' (TIE) 6 ( 175.62' NMP NMP FAIRLAWN DR. ECM 72.17' 24.00' 6 : 6 : 70.00' 6 : 6 : 8.68' 24' WIDE (PRIVATE) ACCESS & UTILITY EASEMENT 24' WIDE (PRIVATE) ACCESS & UTILITY EASEMENT 72.17' 24.00' 1 : PROPOSED CONCRETE DRIVE IRS IRS 10' SIDE SETBACK 10' SIDE SETBACK 30' FRONT SETBACK 25' REAR SETBACK 30' FRONT SETBACK 10' SIDE SETBACK 10' NON-MUNICIPAL UTILITY EASEMENT 23' 25' 38 38 37 37 37 37 37 36 36 36 36 36 34 12" CMP I.E. 32.58 I.E. 32.67 36 36 35 35 POTENTIAL DIVISION LINE BM MAG NAIL SET ELEV. 35.61' NAVD 88 214.7' @ 0.415% 12" RCP INV: 32.9 12" RCP INV: 32.7 W/15'X5'X12" ED 12" RCP 36.6 36.6 36.35 8" SS MAIN 6" WATER MAIN (2) TIE TO EX. 8" SEWER MAIN PER CFPUA SPECIFICATIONS/DETAILS. (2) TIE TO EX. 6" WATER MAIN PER CFPUA SPECIFICATIONS/DETAIL W-2. (2) 5 8 " METER W/ 1" SERVICE (2) 4" C.O./SS SERVICE 4" PVC SS SERVICE @ 1.0% MIN 36" MIN. BURY 5' PRIVATE U.E. 1" WATER SERVICE 36" MIN. BURY 35.9 MATCH EX. ASPHALT 34.75 35.1 CLEAN OUT EX. DITCH SAWCUT & RESTORE TO EX. CONDITIONS JONES ESTER W DB. 3143 PG. 549 ZONING: R-10 USE: RESIDENTIAL WHITE JAMES JR JUDITH REV LIV TRUST DB. 5169 PG. 2806 ZONING: R-10 USE: RESIDENTIAL WHITE JAMES JR JUDITH REV LIV TRUST DB. 5169 PG. 2806 ZONING: R-10 USE: RESIDENTIAL FERGUSON MARGARET DB. 9905 PG. 2298 ZONING: R-10 USE: RESIDENTIAL MCCRIMMON ELI V MARY A DB. 6332 PG. 1266 ZONING: R-10 USE: RESIDENTIAL JACKSON RUSSELL D EMMA H DB. 999 PG. 458 ZONING: R-10 USE: RESIDENTIAL BENNERMAN JOSEPH C BETTY DB. 1417 PG. 392 ZONING: R-10 USE: RESIDENTIAL LACEWELL CAROLYN J DB. 1865 PG. 99 ZONING: R-10 USE: RESIDENTIAL APPROX. LOCATION OF EX. F.H. 5' 5' 20' 141.88' R20' R20' 20' 30' 30' 16' EX. CONC. DRIVE EX. CONC. DRIVE EX. CONC. DRIVE EX. CONC. DRIVE APPROX. LOCATION OF EX. STOP/STREET SIGN EX. CONC. DRIVE 24.00' 16' 24.00' 62-A 13,645 Sq. Feet (11,279 Sq. Feet Net) 62-B 12,720 Sq. Feet (10,608 Sq. Feet NET) 35.58 36.25 35.93 35.5 0$7&+ (; *5$'( 36.85 3:1 GRASSED SWALE 35 20' X 70' SIGHT TRIANGLE (TYP) 10' SIDE SETBACK C-1 1 1" = 20' REVISIONS PROJECT NUMBER: DRAWING NUMBER: CHECKED: APPROVED: DRAWN: DATE: SCALE: SHEET SIZE: CLIENT INFORMATION: VICINITY MAP (NOT TO SCALE): 2021-016 CLIENT INFORMATION: Herrington Classic Homes P.O. Box 538 Wrightsville Beach, NC 28480 Ph. 910-399-5688 OF 3 JAE CDC CDC 24x36 7/22/2021 FAIRLAWN DR DEWITT RD SUNGLOW DR McCLELLAND DR BARCLAY HILLS RD SAINT ROSEA DR N KERR AVE GLEASON RD CLOVER RD ESTATE RD Site PROPERTY LINE PROPOSED LOTLINE SETBACKS RUNOFF DIRECTION CENTER LINE PROPOSED WATERLINE PROPOSED SANITARY SEWER LINE SPOT ELEVATION EX. FIRE HYDRANT LEGEND 25.5 UTILITY NOTES: 1. EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY AUTHORITY PUBLIC MAINS. 2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND. 3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS. 4. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FOR INFORMATION. 5. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BY USCFCCCHR OR ASSE. 6. IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUST PROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATER METER BOX. 7. WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED, SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALL VALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES. 8. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED IN TRAFFIC AREAS. 9. SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS ARE REQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE. 10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMIC EPOXY LINING. 11. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS. 12. NO FLEXIBLE COUPLINGS SHALL BE USED. 13. ALL STAINLESS STEEL FASTENERS SHALL BE 316. 14. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 15. THE BELLSOUTH CONTACT IS STEVE DAYVAULT, BUILDING INDUSTRY CONSULTANT, AT 910-392-8712. CONTACT HIM PRIOR TO STARTING THE PROJECT IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY. 16. THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACE THEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE AT APPROXIMATELY 2' DEEP. 17. SOLID WASTE DISPOSAL IS COW CURBSIDE PICKUP. 18. SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUST EITHER BE UTILIZED OR ABANDONED. 19. 3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS. DEVELOPMENT NOTES: 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH THE CITY OF WILMINGTON LAND DEVELOPMENT CODE. 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS. FIRE & SAFETY NOTES: 1. ADDITIONAL FIRE PROTECTION AND/OR ACCESSIBILITY REQUIREMENTS MAY BE REQUIRED DUE TO ANY SPECIAL CIRCUMSTANCES CONCERNING THE PROJECT. . SITE DATA PARCEL ID: R04910-006-031-000 CURRENT ZONING: R-10 CAMA LAND USE CLASSIFICATION: WATERSHED RESOURCE PROTECTION PROJECT ADDRESS: 4220 DEWITT RD WILMINGTON, NC 28405 CURRENT OWNER: OUR HOUSE YOUR HOME LLC 1114 MERCHANT LN. CAROLINA BEACH, NC 28428 TOTAL ACREAGE IN PROJECT BOUNDARY: 26,364 S.F. (0.605 AC.) TOTAL DISTURBED AREA: $& PROPOSED USED: SINGLE FAMILY RESIDENTIAL BUILDING HEIGHT: 35' MAX MAXIMUM BUILDING LOT COVERAGE: 50% BUILDING SETBACKS: FRONT: REQUIRED= 30' SIDE: REQUIRED= 10' REAR: REQUIRED= 25' EXISTING ON-SITE IMPERVIOUS AREAS: 0 S.F. PROPOSED ON-SITE IMPERVIOUS AREAS: CONCRETE DRIVEWAY 4,477 S.F. (17.0%) PROPOSED OFF-SITE IMPERVIOUS AREAS: CONCRETE DRIVEWAY APRON 512 S.F. EXISTING SEWER AND WATER DEMAND: 0 GPD PROPOSED SEWER AND WATER DEMAND: (2) 3 BDRM RES. @ 360 GAL/RES. = 720 GPD ESTIMATED ADDITIONAL TRIP GENERATION: (2) DU Single Family Residential (ITE CODE 210 ) AM PEAK: 2 PM PEAK: 2 DAILY: 19 TRAFFIC NOTES: 1. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY AND FOR DRIVEWAYS ARE TO BE THERMOPLASTIC AND MEET CITY AND/OR NCDOT STANDARDS. [DETAIL SD 15-13 & SD 11-3 COFW TECH STDS] 2. ALL SIGNS AND PAVEMENT MARKINGS IN AREAS OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES) STANDARDS. [DETAIL SD 15-13 & SD 11-3 COFW TECH STDS] 3. ALL TRAFFIC CONTROL SIGNS AND MARKINGS OFF THE RIGHT-OF-WAY ARE TO BE MAINTAINED BY THE PROPERTY OWNER IN ACCORDANCE WITH MUTCD STANDARDS. 4. A UTILITY CUT PERMIT IS REQUIRED FOR EACH OPEN CUT OF A CITY STREET. NOTE THIS ON THE PLAN AND CONTACT 341-5899 FOR MORE DETAILS. IN CERTAIN CASES AN ENTIRE RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED. 5. IT SHALL BE THE RESPONSIBILITY OF THE SUBDIVIDER TO ERECT OFFICIAL STREET NAME SIGNS AT ALL INTERSECTIONS ASSOCIATED WITH THE SUBDIVISION IN ACCORDANCE WITH THE TECHNICAL STANDARDS AND SPECIFICATIONS MANUAL. THE SUBDIVIDER MAY ACQUIRE AND ERECT OFFICIAL STREET NAME SIGNS OR MAY CHOOSE TO CONTRACT WITH THE CITY TO INSTALL THE STREET SIGNS AND THE SUBDIVIDER SHALL PAY THE COST OF SUCH INSTALLATION. CONTACT TRAFFIC ENGINEERING AT 341-7888 TO DISCUSS INSTALLATION OF TRAFFIC AND STREET NAME SIGNS. PROPOSED STREET NAMES MUST BE APPROVED PRIOR TO INSTALLATION OF STREET NAME SIGNS. 6. ANY BROKEN OR MISSING SIDEWALK PANELS, DRIVEWAY PANELS AND CURBING WILL BE REPLACED. 7. CONTACT 811 PRIOR TO CONTACTING THE CITY OF WILMINGTON, TRAFFIC ENGINEERING REGARDING THE UTILITIES IN THE RIGHT OF WAY. 8. ALL PROPOSED VEGETATION WITHIN SIGHT TRIANGLES SHALL NOT INTERFERE WITH CLEAR VISUAL SIGHT LINES FROM 30"-10'. [SEC.18-556 COFW LDC] 9. CONTACT TRAFFIC ENGINEERING AT (910) 341-7888 TO DISCUSS STREET LIGHTING OPTIONS. SITE, GRADING, DRAINAGE, & UTILITIES PLAN SURVEY NOTES: 1. EXISTING SURVEY INFORMATION PROVIDED BY VERNON DEREK DANFORD PLS# L-4528 2. SITE IS LOCATED IN FLOOD ZONE "X" PER FIRM MAP# 3720313800K DATED: 8/28/2018. 40' 20' 10' 20' 0' Scale: 1"=20'

Upload: others

Post on 02-Apr-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

DE

WIT

T R

OA

D(6

0' P

UB

LIC

R/W

)

63SECTION 3FAIRLAWNMB 7, PG 47

61 60

32-A

SECTION 3FAIRLAWNMB 7, PG 47

SECTION 3FAIRLAWNMB 7, PG 47

SECTION IFAIRLAWNMB 6, PG 6

31SECTION IFAIRLAWNMB 6, PG 6

25' RE

AR

SETB

AC

K

S 72°29'00" E 96.17'

NMP

N 83°48'00" W

98.08'

EIP

EIP

EIPPT

IRS

(TIE)N 17°31'00" E

30.00'

N 17°31'00" E29.99'

(TIE

)N 72°28'57" W

357.

51'

(TIE

)S 72°29'07" E

175.

62'

NMP

NMP

FAIRLAWN DR.

ECM

72.1

7'

24.0

0'

S 17°31'00" W 141.88'S 17°31'00" W 141.88'

70.00'

S 17°31'00" W 141.88'S 17°31'00" W 122.63'

8.68'

24' WIDE(PRIVATE)

ACCESS & UTILITYEASEMENT

24' WIDE(PRIVATE)ACCESS & UTILITYEASEMENT

72.1

7'24

.00'

N 72°29'00" W 96.17'

PROPOSED CONCRETE DRIVE

IRS

IRS

10' SIDE SETBACK

10' SIDE SETBACK

30' F

RO

NT

SETB

AC

K

25' R

EA

R S

ETB

AC

K

30' F

RO

NT

SETB

AC

K

10' SIDE SETBACK

10' N

ON

-MU

NIC

IPA

LU

TILI

TY E

ASE

ME

NT

23'

25'

38

38

37

37

37

3737

36

36

36

36

36

34

12"

CM

P

I.E. 32.58

I.E. 32.67

36

3635

35

POTENTIALDIVISION LINE

BM

MAG NAIL SETELEV. 35.61'NAVD 88

214.

7' @

0.4

15%

12" RCPINV: 32.9

12" RCP INV: 32.7W/15'X5'X12" ED

12"

RC

P

36.6

36.6

36.35

8" S

S M

AIN

6" W

ATE

R M

AIN

(2) TIE TO EX. 8" SEWER MAIN PER CFPUASPECIFICATIONS/DETAILS.

(2) TIE TO EX. 6" WATER MAIN PER CFPUASPECIFICATIONS/DETAIL W-2.

(2) 58" METER W/ 1" SERVICE

(2) 4" C.O./SS SERVICE

4" PVC SS SERVICE @ 1.0% MIN36" MIN. BURY

5' P

RIV

ATE

U.E

.

1" WATER SERVICE 36" MIN. BURY 35.9

MATCH EX. ASPHALT±35.45

34.75

35.1

CLEAN OUT EX. DITCH

SAWCUT & RESTORE TO EX.CONDITIONS

JONES ESTER WDB. 3143 PG. 549

ZONING: R-10USE: RESIDENTIAL

WHITE JAMES JRJUDITH REV LIV

TRUSTDB. 5169 PG. 2806

ZONING: R-10USE: RESIDENTIAL

WHITE JAMES JRJUDITH REV LIV

TRUSTDB. 5169 PG. 2806

ZONING: R-10USE: RESIDENTIAL

FERGUSON MARGARETDB. 9905 PG. 2298

ZONING: R-10USE: RESIDENTIAL

MCCRIMMON ELI V MARY ADB. 6332 PG. 1266

ZONING: R-10USE: RESIDENTIAL

JACKSON RUSSELL D EMMA HDB. 999 PG. 458ZONING: R-10

USE: RESIDENTIAL

BENNERMAN JOSEPH C BETTYDB. 1417 PG. 392ZONING: R-10

USE: RESIDENTIAL

LACEWELL CAROLYN JDB. 1865 PG. 99ZONING: R-10

USE: RESIDENTIAL

APPROX. LOCATION OF EX. F.H.

5'5'

20'

141.88'

R20'

R20'

20'30'

30'

16'

EX

.C

ON

C.

DR

IVE

EX

.C

ON

C.

DR

IVE

EX.CONC.DRIVE

EX.CONC.DRIVE

APPROX. LOCATION OF EX. STOP/STREET SIGN

EX.CONC.DRIVE

24.0

0'

16'

24.00'62-A

13,645 Sq. Feet(11,279 Sq. Feet Net)

62-B12,720 Sq. Feet

(10,608 Sq. Feet NET)

35.58

36.25

35.93

35.5 MATCH EX. GRADE ±35.0

36.85

3:1 GRASSED SWALE

35

20' X 70' SIGHTTRIANGLE (TYP)

10' SIDE SETBACK

C-11

1" = 20'

REVISIONS

PROJECT NUMBER:

DRAWING NUMBER:

CHECKED:

APPROVED:

DRAWN:

DATE:

SCALE:

SHEET SIZE:

CLIENT INFORMATION:

VICINITY MAP (NOT TO SCALE):

2021-016

CLIENT INFORMATION:

Herrington Classic HomesP.O. Box 538Wrightsville Beach, NC 28480Ph. 910-399-5688

OF 3

JAE

CDC

CDC

24x36

7/22/2021

FAIRLAWN DR

DEWITT RD

SUNGLOW DR

McCLELLAND DR

BA

RC

LAY

HIL

LS R

D

SAIN

T R

OSE

A D

R

N K

ER

R A

VE

GLE

ASO

N R

D

CLO

VE

R R

D

EST

ATE

RD

Site

PRELIMIN

ARY

DRAWIN

G DO N

OT USE

FOR CONSTRUCTION

PROPERTY LINEPROPOSED LOTLINESETBACKSRUNOFF DIRECTIONCENTER LINEPROPOSED WATERLINEPROPOSED SANITARY SEWER LINE

SPOT ELEVATION

EX. FIRE HYDRANT

LEGEND

25.5

UTILITY NOTES:1. EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM CAPE FEAR PUBLIC UTILITY

AUTHORITY PUBLIC MAINS.2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED UNDERGROUND.3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER CFPUA TECHNICAL SPECIFICATIONS & STANDARDS.4. PROJECT SHALL COMPLY WITH CFPUA CROSS CONNECTION CONTROL REQUIREMENTS. WATER METER(S) CANNOT BE RELEASED

UNTIL ALL REQUIREMENTS ARE MET AND N.C.D.E.N.R. HAS ISSUED THEIR "FINAL APPROVAL.". CALL 332-6558 FORINFORMATION.

5. ANY BACKFLOW PREVENTION DEVICES REQUIRED BY THE CFPUA WILL NEED TO BE ON THE LIST OF APPROVED DEVICES BYUSCFCCCHR OR ASSE.

6. IF CONTRACTOR DESIRES CFPUA WATER FOR CONSTRUCTION, HE SHALL APPLY IN ADVANCE FOR THIS SERVICE AND MUSTPROVIDE A REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION DEVICE ON THE DEVELOPER'S SIDE OF THE WATERMETER BOX.

7. WHEN PVC WATER MAINS AND SERVICES ARE PROPOSED, THE PIPES ARE TO BE MARKED WITH NO. 10 INSULATED,SINGLE-STRAND COPPER WIRE INSTALLED & STRAPPED TO THE PIPES WITH DUCT TAPE. THIS IS TO BE ACCESSIBLE IN ALLVALVES AND METER BOXES TO AID IN FUTURE LOCATION OF FACILITIES.

8. SEWER GUARDS REQUIRED AT ALL MANHOLES. STAINLESS STEEL SEWER GUARDS REQUIRED AT MANHOLES LOCATED INTRAFFIC AREAS.

9. SERVICES SHALL BE PERPENDICULAR TO MAIN AND TERMINATE AT RIGHT-OF-WAY LINE. SERVICES IN CUL-DE-SACS AREREQUIRED TO BE PERPENDICULAR OR MUST ORIGINATE IN MANHOLE AND TERMINATE AT RIGHT-OF-WAY LINE.

10. ALL SERVICES TYING INTO DUCTILE IRON MAINS SHALL BE CONSTRUCTED OF CLASS 50 D.I.P. WITH PROTECTO 401 CERAMICEPOXY LINING.

11. MINIMUM 10' UTILITIES EASEMENT PROVIDED ALONG THE FRONTAGE OF ALL LOTS AND AS SHOWN FOR NEW DEVELOPMENTS.12. NO FLEXIBLE COUPLINGS SHALL BE USED.13. ALL STAINLESS STEEL FASTENERS SHALL BE 316.14. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING CONSTRUCTION.

CALL NC811 AT 811 OR 1-800-632-4949. CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ANY UTILITIES,CURB & GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIREDTO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM.

15. THE BELLSOUTH CONTACT IS STEVE DAYVAULT, BUILDING INDUSTRY CONSULTANT, AT 910-392-8712. CONTACT HIM PRIOR TOSTARTING THE PROJECT IN ORDER TO FACILITATE GOOD COMMUNICATION AND MAXIMUM FLEXIBILITY.

16. THE PROCESS FOR TELEPHONE CABLE PLACEMENT: * FINAL GRADE WILL NEED TO BE ESTABLISHED. * POWER WILL PLACETHEIR CABLE FIRST - APPROXIMATELY 3' DEEP. * BELLSOUTH & CABLE TV WILL THEN PLACE THEIR CABLE ATAPPROXIMATELY 2' DEEP.

17. SOLID WASTE DISPOSAL IS COW CURBSIDE PICKUP.18. SHOULD ADDITIONAL SERVICES BE LOCATED DURING CONSTRUCTION, THEY MUST EITHER BE UTILIZED OR ABANDONED.19. 3' SEPARATION BETWEEN JOINTS, FITTINGS, SERVICE SADDLES AND WYES ARE REQUIRED FOR SS AND WATER TAPS.

DEVELOPMENT NOTES:1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH THE CITY OF WILMINGTON LAND DEVELOPMENT CODE.2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & NEW HANOVER COUNTY REGULATIONS.

FIRE & SAFETY NOTES:1. ADDITIONAL FIRE PROTECTION AND/OR ACCESSIBILITY REQUIREMENTS MAY BE REQUIRED DUE TO ANY SPECIAL

CIRCUMSTANCES CONCERNING THE PROJECT. .

SITE DATA

PARCEL ID: R04910-006-031-000

CURRENT ZONING: R-10

CAMA LAND USE CLASSIFICATION: WATERSHED RESOURCE PROTECTION

PROJECT ADDRESS: 4220 DEWITT RDWILMINGTON, NC 28405

CURRENT OWNER: OUR HOUSE YOUR HOME LLC1114 MERCHANT LN.CAROLINA BEACH, NC 28428

TOTAL ACREAGE IN PROJECT BOUNDARY: 26,364 S.F. (0.605 AC.)

TOTAL DISTURBED AREA: ±0.6 AC.

PROPOSED USED: SINGLE FAMILY RESIDENTIAL

BUILDING HEIGHT: 35' MAX

MAXIMUM BUILDING LOT COVERAGE: 50%

BUILDING SETBACKS:FRONT: REQUIRED= 30'SIDE: REQUIRED= 10'REAR: REQUIRED= 25'

EXISTING ON-SITE IMPERVIOUS AREAS: 0 S.F.

PROPOSED ON-SITE IMPERVIOUS AREAS:CONCRETE DRIVEWAY 4,477 S.F. (17.0%)

PROPOSED OFF-SITE IMPERVIOUS AREAS:CONCRETE DRIVEWAY APRON 512 S.F.

EXISTING SEWER AND WATER DEMAND: 0 GPD

PROPOSED SEWER AND WATER DEMAND:(2) 3 BDRM RES. @ 360 GAL/RES. = 720 GPD

ESTIMATED ADDITIONAL TRIP GENERATION:(2) DU Single Family Residential (ITE CODE 210 )

AM PEAK: 2 PM PEAK: 2 DAILY: 19

TRAFFIC NOTES:1. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS-OF-WAY AND FOR DRIVEWAYS ARE TO BE THERMOPLASTIC AND MEET CITY

AND/OR NCDOT STANDARDS. [DETAIL SD 15-13 & SD 11-3 COFW TECH STDS]2. ALL SIGNS AND PAVEMENT MARKINGS IN AREAS OPEN TO PUBLIC TRAFFIC ARE TO MEET MUTCD (MANUAL ON UNIFORM

TRAFFIC CONTROL DEVICES) STANDARDS. [DETAIL SD 15-13 & SD 11-3 COFW TECH STDS]3. ALL TRAFFIC CONTROL SIGNS AND MARKINGS OFF THE RIGHT-OF-WAY ARE TO BE MAINTAINED BY THE PROPERTY OWNER IN

ACCORDANCE WITH MUTCD STANDARDS.4. A UTILITY CUT PERMIT IS REQUIRED FOR EACH OPEN CUT OF A CITY STREET. NOTE THIS ON THE PLAN AND CONTACT 341-5899

FOR MORE DETAILS. IN CERTAIN CASES AN ENTIRE RESURFACING OF THE AREA BEING OPEN CUT MAY BE REQUIRED.5. IT SHALL BE THE RESPONSIBILITY OF THE SUBDIVIDER TO ERECT OFFICIAL STREET NAME SIGNS AT ALL INTERSECTIONS

ASSOCIATED WITH THE SUBDIVISION IN ACCORDANCE WITH THE TECHNICAL STANDARDS AND SPECIFICATIONS MANUAL. THESUBDIVIDER MAY ACQUIRE AND ERECT OFFICIAL STREET NAME SIGNS OR MAY CHOOSE TO CONTRACT WITH THE CITY TOINSTALL THE STREET SIGNS AND THE SUBDIVIDER SHALL PAY THE COST OF SUCH INSTALLATION. CONTACT TRAFFICENGINEERING AT 341-7888 TO DISCUSS INSTALLATION OF TRAFFIC AND STREET NAME SIGNS. PROPOSED STREET NAMES MUSTBE APPROVED PRIOR TO INSTALLATION OF STREET NAME SIGNS.

6. ANY BROKEN OR MISSING SIDEWALK PANELS, DRIVEWAY PANELS AND CURBING WILL BE REPLACED.7. CONTACT 811 PRIOR TO CONTACTING THE CITY OF WILMINGTON, TRAFFIC ENGINEERING REGARDING THE UTILITIES IN THE

RIGHT OF WAY.8. ALL PROPOSED VEGETATION WITHIN SIGHT TRIANGLES SHALL NOT INTERFERE WITH CLEAR VISUAL SIGHT LINES FROM 30"-10'.

[SEC.18-556 COFW LDC]9. CONTACT TRAFFIC ENGINEERING AT (910) 341-7888 TO DISCUSS STREET LIGHTING OPTIONS.

SITE

, GR

AD

ING

, DR

AIN

AG

E,

& U

TILI

TIE

S PL

AN

SURVEY NOTES:1. EXISTING SURVEY INFORMATION PROVIDED BY VERNON DEREK DANFORD PLS# L-45282. SITE IS LOCATED IN FLOOD ZONE "X" PER FIRM MAP# 3720313800K DATED: 8/28/2018.

40'20'10'20' 0'

Scale: 1"=20'

waltonj
Received

C-22

DE

TAIL

S

NTS

REVISIONS

PROJECT NUMBER:

DRAWING NUMBER:

CHECKED:

APPROVED:

DRAWN:

DATE:

SCALE:

SHEET SIZE:

CLIENT INFORMATION:

VICINITY MAP (NOT TO SCALE):

2021-016

CLIENT INFORMATION:

Herrington Classic HomesP.O. Box 538Wrightsville Beach, NC 28480Ph. 910-399-5688

OF 3

JAE

CDC

CDC

24x36

7/22/2021

FAIRLAWN DR

DEWITT RD

SUNGLOW DR

McCLELLAND DR

BA

RC

LAY

HIL

LS R

D

SAIN

T R

OSE

A D

R

N K

ER

R A

VE

GLE

ASO

N R

D

CLO

VE

R R

D

EST

ATE

RD

Site

PRELIMIN

ARY

DRAWIN

G DO N

OT USE

FOR CONSTRUCTION

ENERGY DISSIPATORNTS

SECTION A - A FILTER FABRIC

SEE PLAN

SEE PLAN

1. CLASS "B" RIP RAP TO BE USED FOR ALL ENERGY DISSIPATOR AREAS.NOTES:

SITE WORK NOTES:1. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS BOTH ON AND ADJACENT TO

THE SITE.2. CLEARING: CONTRACTOR SHALL REMOVE ALL TREES AND VEGETATION WITHIN LIMITS OF CONSTRUCTION UNLESS

OTHERWISE DESIGNATED TO REMAIN.3. GRUBBING AND STRIPPING: CONTRACTOR SHALL RAKE AND REMOVE ROOTS, STUMPS, VEGETATION, DEBRIS, EXISTING

STRUCTURES ABOVE AND BELOW GRADE, ORGANIC MATERIAL OR ANY OTHER UNSUITABLE MATERIAL WITHIN LIMITS OFCONSTRUCTION.

4. MUCKING: CONTRACTOR SHALL COORDINATE WITH OWNER AND THEIR GEOTECHNICAL REPRESENTATIVE TO COORDINATEREMOVAL OF ANY SOFT AREAS.

5. DISPOSAL: CLEARED, GRUBBED, STRIPPED OR OTHER WASTE MATERIAL SHALL BE REMOVED FROM SITE AND DISPOSED OF INA PROPERLY PERMITTED FACILITY.

6. FILL AND COMPACTION SHOULD COMPLY WITH GEOTECHNICAL RECOMMENDATIONS.7. THE CONTRACTOR SHALL NOTE THAT THE GRADING PLAN MAY NOT REPRESENT A BALANCED EARTHWORK CONDITION. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR CUT AND FILL QUANTITIES AND COMPLETE INSTALLATION TO SPECIFIED GRADES.8. THE CONTRACTOR SHALL FURNISH SUITABLE BORROW MATERIAL FROM AN OFF-SITE PROPERLY PERMITTED FACILITY AS

REQUIRED.9. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS. IT SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXACT ELEVATIONS AND LOCATIONS OF ALL EXISTING UTILITIESAT ALL CROSSINGS PRIOR TO COMMENCING TRENCH EXCAVATION. IF ACTUAL CLEARANCES ARE LESS THAN INDICATED ONPLAN, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. ANYCONDITION DISCOVERED OR EXISTING THAT WOULD NECESSITATE A MODIFICATION OF THESE PLANS SHALL BE BROUGHT TOTHE ATTENTION OF THE DESIGN ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION.

10. NO CONSTRUCTION IS TO BEGIN BEFORE LOCATION OF EXISTING UTILITIES HAS BEEN DETERMINED. CALL "NC ONE-CALL" ATLEAST 48 HOURS BEFORE COMMENCING CONSTRUCTION.

11. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES DURING CONSTRUCTION.BEFORE COMMENCING ANY EXCAVATIONS IN OR ALONG ROADWAYS OR RIGHT-OF-WAYS, PUBLIC AREAS OR IN PRIVATEEASEMENTS, THE CONTRACTOR SHALL NOTIFY ALL APPROPRIATE PERSONNEL OF THEIR INTENT TO EXCAVATE, IN WRITING,NOT LESS THAN 10 DAYS PRIOR TO EXCAVATING.

12. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE DISCONNECTION/ RECONNECTION AND/OR THE RELOCATION OFALL EXISTING UTILITIES WITH APPROPRIATE PERSONNEL.

13. CONTRACTOR SHALL ADJUST ALL MANHOLES, VALVE & CURB BOXES TO FINAL GRADE UPON COMPLETION OF ALLCONSTRUCTION. ANY BOXES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR SHALL BE REPAIRED AT THEEXPENSE OF THE CONTRACTOR.

14. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AT THE SITE. FURTHERMORE THE CONTRACTOR SHALL REPORT ALLDISCREPANCIES OR QUESTIONS TO THE ENGINEER PRIOR TO INSTALLATION.

15. THE CONTRACTOR SHALL PROVIDE ANY AND ALL LAYOUT REQUIRED TO CONSTRUCT HIS WORK UNLESS OTHERWISE DIRECTEDBY OWNER.

16. ALL SERVICE CONNECTIONS SHALL BE INSTALLED TO MEET ALL LOCAL, STATE, AND CFPUA CODES. METERS, TAPS, MATERIALS,WORKMANSHIP AND ALL FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH ALLREQUIREMENTS.

17. ALL BACKFILL FROM UTILITY INSTALLATION MUST BE COMPACTED OR AMENDED TO PROVIDE TRAFFIC BEARING CAPACITY.GEOTECHNICAL ENGINEER TO BE CONSULTED AT CONTRACTORS COST AS NECESSARY.

18. ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEERPRIOR TO INSTALLATION. ALL AREAS SHALL BE SLOPED TO DRAIN AWAY FROM BUILDINGS AT ALL TIMES.

19. CONCRETE FOR WALKS, CURBS AND DRIVES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS - AIRENTRAINED.

NTS

3:1 SLOPE3:1 SLOPE

TYPICAL 3:1 GRASS SWALE

1. SWALES TO BE LINED WITH EXCELSIOR MAT &SEEDED IN ACCORDANCE WITH SPECIFICATIONSIMMEDIATELY.

0.5' MIN

6" CONCRETE

24' PRIVATE ACCESS EASEMENT

ASPHALT (16')

4" ABC

EDGE OF PAVEMENT

24' PRIVATE EASEMENT DRIVEWAY SECTION

1/4" PER FOOT

NTS

COMPACTED SUBGRADESHEET FLOW TO PROPOSED

3:1 GRASSED SWALE