  • Power Electronics Single Phase AC-AC Converters

    1

    Dr. Firas Obeidat

  • 2

    Table of contents

    1 • Introduction

    2 • The Single Phase AC Voltage Controller

    3

    • The Single Phase AC Voltage Controller - Resistive Load

    4 • The Single Phase AC Voltage Controller - RL Load

    Dr. Firas Obeidat Faculty of Engineering Philadelphia University

  • 3 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    Introduction

    An ac voltage controller is a converter that controls the voltage, current, and average power delivered to an ac load from an ac source.

    The phase-controlled ac voltage controller has several practical uses including light-dimmer circuits and speed control of induction motors.

    In a switching scheme called phase control, switching takes place during every cycle of the source, in effect removing some of the source waveform before it reaches the load.

    Integral-cycle control, the source is connected and disconnected for several cycles at a time.

  • 4 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller

    Basic Operation

    For the single phase AC voltage controller

    shown, electronic switches are shown as parallel

    thyristors (SCRs). This SCR arrangement

    makes it possible to have current in either

    direction in the load. This SCR connection is

    called antiparallel or inverse parallel because

    the SCRs carry current in opposite directions. A

    triac is equivalent to the antiparallel SCRs.

    Other controlled switching devices can be used

    instead of SCRs.

    Load current contains both positive and negative half-cycles. An analysis

    identical to that done for the controlled half-wave rectifier can be done on a

    half cycle for the voltage controller. Then, by symmetry, the result can be

    extrapolated to describe the operation for the entire period.

    S1 conducts if a gate signal is applied during the positive half-cycle of the

    source. S1 conducts until the current in it reaches zero.

    A gate signal is applied to S2 during the negative half-cycle of the source,

    providing a path for negative load current.

    vs

    L

    o

    a

    d

    + -vsw

    S1

    S2+

    -

    +

    -

    io

    vo

  • 5 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller

    Basic Operation

    Basic observations about this controller

    The SCRs cannot conduct simultaneously.

    The load voltage is the same as the source voltage when either SCR is on. The load voltage is zero when both SCRs are OFF.

    The switch voltage vsw is zero when either SCR is ON and is equal to the source voltage when neither is ON.

    The average current in the source and load is zero if the SCRs are on for equal time intervals. The average current in each SCR is not zero because of unidirectional SCR current.

    The rms current in each SCR is 1/√2 times the rms load current if the SCRs are on for equal time intervals.

  • 6 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    vs

    + -vsw

    S1

    S2+

    -

    +

    -

    io

    voR

    The Single Phase AC Voltage Controller - Resistive Load

    𝑣𝑠 𝜔𝑡 = 𝑉𝑚𝑠𝑖𝑛𝜔𝑡

    𝑣𝑠 𝜔𝑡 = 𝑉𝑚𝑠𝑖𝑛𝜔𝑡 𝛼 < 𝜔𝑡 < 𝜋 𝑎𝑛𝑑 𝜋 + 𝛼 < 𝜔𝑡 < 2𝜋

    0 𝑜𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒

    Let the voltage source be

    Output voltage is

    The rms load voltage is

    𝑉𝑜,𝑟𝑚𝑠 =1

    𝜋 (𝑉𝑚𝑠𝑖𝑛𝜔𝑡)

    2 𝑑𝜔𝑡

    𝜋

    α

    =𝑉𝑚

    2 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋

  • 7 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - Resistive Load

    The power factor of the load is

    The rms current in the load and the source is

    𝐼𝑜,𝑟𝑚𝑠 =𝑉𝑜,𝑟𝑚𝑠

    𝑅=

    𝑉𝑚

    𝑅 2 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋

    𝑝𝑓 =𝑃

    𝑆=

    𝑉𝑜,𝑟𝑚𝑠2 𝑅

    𝑉𝑠,𝑟𝑚𝑠𝐼𝑠,𝑟𝑚𝑠=

    𝑉𝑜,𝑟𝑚𝑠2 𝑅

    𝑉𝑠,𝑟𝑚𝑠(𝑉𝑜,𝑟𝑚𝑠 𝑅 )=

    𝑉𝑜,𝑟𝑚𝑠𝑉𝑠,𝑟𝑚𝑠

    =

    𝑉𝑚2

    1 −𝛼𝜋 +

    𝑠𝑖𝑛2𝛼2𝜋

    𝑉𝑚 2

    𝑝𝑓 = 1 −𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋

    The pf=1 for α=0, which is the same as for an uncontrolled resistive load, and

    the power factor for α>0 is less than 1.

    The average source current is zero because of half-wave symmetry.

    𝐼𝑠,𝐴𝑣𝑔 = 𝐼𝑜,𝐴𝑣𝑔 = 0

  • 8 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - Resistive Load

    The average SCR current is

    𝐼𝑆𝐶𝑅,𝐴𝑣𝑔 =1

    2𝜋

    𝑉𝑚𝑠𝑖𝑛𝜔𝑡

    𝑅𝑑𝜔𝑡

    𝜋

    𝛼

    =𝑉𝑚2𝜋𝑅

    (1 + 𝑐𝑜𝑠𝛼)

    𝐼𝑆𝐶𝑅,𝑟𝑚𝑠 =1

    2𝜋 (

    𝑉𝑚𝑠𝑖𝑛𝜔𝑡

    𝑅)2 𝑑𝜔𝑡

    𝜋

    α

    =𝑉𝑚2𝑅

    1 −𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋

    The rms SCR current is

    𝐼𝑆𝐶𝑅,𝑟𝑚𝑠 =𝑉𝑚

    2 2𝑅 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋=

    𝐼𝑜,𝑟𝑚𝑠

    2

    πα 2π 2π+α 3πωt

    iS1

    vs/R

  • 9 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    Example: The single-phase ac voltage controller has a 120-V rms 60-Hz source.

    The load resistance is 15 Ω. Determine (a) the delay angle required to deliver

    500 W to the load, (b) the rms source current, (c) the rms and average currents

    in the SCRs, (d) the power factor.

    𝑉𝑜,𝑟𝑚𝑠 =𝑉𝑚

    2 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋=

    2 × 120

    2 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋

    𝑃 =𝑉𝑜,𝑟𝑚𝑠

    2

    𝑅 → 𝑉𝑜,𝑟𝑚𝑠

    2 = 𝑃𝑅 = 500 × 15 = 7500

    𝑉𝑜,𝑟𝑚𝑠2 = 1202(1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋)

    ∴ 7500 = 14400(1 −𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋)

    𝛼

    𝜋−

    𝑠𝑖𝑛2𝛼

    2𝜋= 0.479

    2𝛼 − 𝑠𝑖𝑛2𝛼 = 3.01

    𝛼 = 1.54 rad = 88.1𝑜

    (a)

    The Single Phase AC Voltage Controller - Resistive Load

  • 10 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - Resistive Load

    (b)

    𝐼𝑜,𝑟𝑚𝑠 =𝑉𝑜,𝑟𝑚𝑠

    𝑅=

    86.6

    15= 5.77 A

    𝑉𝑜,𝑟𝑚𝑠2 = 7500 → 𝑉𝑜,𝑟𝑚𝑠 = 86.6 From (a)

    𝐼𝑆𝐶𝑅,𝐴𝑣𝑔 =𝑉𝑚2𝜋𝑅

    1 + 𝑐𝑜𝑠𝛼 =2 × 120

    2𝜋151 + 𝑐𝑜𝑠88.1 = 1.86 A

    𝐼𝑆𝐶𝑅,𝑟𝑚𝑠 =𝐼𝑜,𝑟𝑚𝑠

    2=

    5.77

    2= 4.08 A

    (c)

    𝑝𝑓 =𝑃

    𝑆=

    𝑃

    𝑉𝑠,𝑟𝑚𝑠𝐼𝑠,𝑟𝑚𝑠= 1 −

    𝛼

    𝜋+

    𝑠𝑖𝑛2𝛼

    2𝜋=

    500

    120 × 5.77= 0.722 (d)

  • 11 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    vs

    + -vsw

    S1

    S2+

    -

    +

    -

    io

    vo

    R

    L

    When a gate signal is applied to S1 at 𝜔t=α in single phase AC voltage controller with

    RL load, Kirchhoff’s voltage law for the

    circuit is expressed as.

    𝑉𝑚𝑠𝑖𝑛𝜔𝑡 = 𝑅𝑖𝑜 𝑡 + 𝐿𝑑𝑖𝑜 𝑡

    𝑑𝑡

    The solution for current in this equation

    (as obtained in the controlled half wave

    rectifier section) is

    𝑖𝑜 𝜔𝑡 = 𝑉𝑚𝑍

    sin 𝜔𝑡 − 𝜃 − sin (𝛼 − 𝜃)𝑒(𝛼−𝜔𝑡) 𝜔𝜏 𝛼 ≤ 𝜔𝑡 ≤ 𝛽

    0 𝑜𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒

    where

    𝑍 = 𝑅2 + (𝜔𝐿)2 𝜃 = 𝑡𝑎𝑛−1(𝜔𝐿

    𝑅)

    The extinction angle 𝛽 is the angle at which the current returns to zero, when 𝜔𝑡= 𝛽,

    𝑖𝑜 𝛽 =𝑉𝑚𝑍

    sin 𝛽 − 𝜃 − sin (𝛼 − 𝜃)𝑒(𝛼−𝛽) 𝜔𝜏

    (1)

    (2)

  • 12 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    A gate signal is applied to S2 at 𝜔t=π+α, and the load current is negative but has a

    form identical to that of the positive half-

    cycle.

    The above equation must be solved

    numerically for 𝛽.

    The angle (𝛽-α) is called the conduction angle 𝛶.

    𝛶 =𝛽-α

    In the interval between π and 𝛽 when the source voltage is negative and the load

    current is still positive, S2 cannot be

    turned on because it is not forward biased.

    The gate signal to S2 must be delayed at

    least until the current in S1 reaches zero,

    at 𝜔t= 𝛽. The delay angle is therefore at least 𝛽- π.

    α≥𝛽- π

  • 13 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    When α=θ, equation (2) becomes

    sin 𝛽 − 𝜃 = 0

    which has a solution

    𝛽 − 𝜃 = π

    Therefore

    𝛶 = 𝜋 When α=θ

    When 𝛶=𝜋, one SCR is always conducting, and the voltage across the load is the same as the voltage of the source. The load voltage and current are

    sinusoids for this case, and the circuit is analyzed using phasor analysis for AC

    circuits. The power delivered to the load is continuously controllable between

    the two extremes corresponding to full source voltage and zero.

    The expression of rms load current is

    𝐼𝑜,𝑟𝑚𝑠 =1

    𝜋 𝑖𝑜

    2(𝜔𝑡) 𝑑𝜔𝑡

    𝛽

    α

    =1

    𝜋

    𝑉𝑚𝑍

    sin 𝜔𝑡 − 𝜃 −𝑉𝑚𝑍

    sin (𝛼 − 𝜃)𝑒(𝛼−𝜔𝑡) 𝜔𝜏 2

    𝑑𝜔𝑡

    𝛽

    α

  • 14 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    The average output voltage can be found as

    An other way to find the expression of rms load current

    is

    𝐼𝑜,𝑟𝑚𝑠 =1

    𝑅2 + (𝜔𝐿)2

    𝑉𝑚

    2

    1

    𝜋(𝛽 − 𝛼 −

    1

    2𝑠𝑖𝑛2𝛽 +

    1

    2𝑠𝑖𝑛2𝛼)

    Power absorbed by the load is determined from

    𝑃 = 𝐼𝑜,𝑟𝑚𝑠2𝑅

    The power factor of the load is

    𝑝𝑓 =𝑃

    𝑆=

    𝑉𝑜,𝑟𝑚𝑠𝐼𝑜,𝑟𝑚𝑠𝑉𝑠,𝑟𝑚𝑠𝐼𝑠,𝑟𝑚𝑠

    =𝑉𝑜,𝑟𝑚𝑠𝑉𝑠,𝑟𝑚𝑠

    =1

    𝜋(𝛽 − 𝛼 −

    1

    2𝑠𝑖𝑛2𝛽 +

    1

    2𝑠𝑖𝑛2𝛼)

    𝑉𝑜,𝑟𝑚𝑠 =1

    𝜋 (𝑉𝑚𝑠𝑖𝑛𝜔𝑡)

    2 𝑑𝜔𝑡

    𝛽

    α

    =𝑉𝑚

    2

    1

    𝜋(𝛽 − 𝛼 −

    1

    2𝑠𝑖𝑛2𝛽 +

    1

    2𝑠𝑖𝑛2𝛼)

  • 15 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    Each SCR carries one-half of the current waveform, making the average SCR

    current

    𝐼𝑆𝐶𝑅,𝐴𝑣𝑔 =1

    2𝜋 𝑖𝑜(𝜔𝑡) 𝑑𝜔𝑡

    𝛽

    α

    =1

    2𝜋

    𝑉𝑚𝑍

    sin 𝜔𝑡 − 𝜃 − sin (𝛼 − 𝜃)𝑒(𝛼−𝜔𝑡) 𝜔𝜏 𝑑𝜔𝑡

    𝛽

    α

    The rms current in each SCR is

    𝐼𝑆𝐶𝑅,𝑟𝑚𝑠 =𝐼𝑜,𝑟𝑚𝑠

    2

    The average load current is zero,

    𝐼𝑜,𝐴𝑣𝑔 = 0

  • 16 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    Example: For the single-phase voltage controller with RL load, the source is

    120Vrms at 60 Hz, and the load is a series RL combination with R=20Ω and

    L=50mH. The delay angle α is 90. Determine (a) an expression for load current

    for the first half-period, (b) the rms load current, (c) the rms SCR current, (d)

    the average SCR current, (e) the power delivered to the load, and (f) the power

    factor.

    (a)

    The Single Phase AC Voltage Controller - RL Load

    The extinction angle is determined from the numerical solution of i(β)=0 in the

    above equation.

  • 17 Dr. Firas Obeidat Faculty of Engineering Philadelphia University

    The Single Phase AC Voltage Controller - RL Load

    (b)

    (c)

    (d)

    (e)

    (f)

    𝐼𝑜,𝑟𝑚𝑠 =1

    27.5× 120 ×

    1

    𝜋(3.83 − 1.57 −

    1

    2𝑠𝑖𝑛440 + 0) = 3.27 A

    𝐼𝑜,𝑟𝑚𝑠 =1

    𝑅2 + (𝜔𝐿)2

    𝑉𝑚

    2

    1

    𝜋(𝛽 − 𝛼 −

    1

    2𝑠𝑖𝑛2𝛽 −

    1

    2𝑠𝑖𝑛2𝛼)

    Or

  • 18