Single-blind testing of a regional, continuous monitoring system for finding methane leaks from oil and gas operations Caroline Alden 1,2 , Sean Coburn 2 , Robert Wright 2 , Esther Baumann 3 , Kevin Cossel 3 , Colm Sweeney 4 , Anna Karion 3 , Alex Rybchuk 2 , Kuldeep Prasad 3 , Ian Coddington 3 , Gregory Rieker 2 1 Cooperative Institute for Research in Environmental Sciences, 2 University of Colorado, 3 National Institute of Standards and Technology, 4 National Oceanic and Atmospheric Administration

Upload: others

Post on 03-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Single-blind testing of a regional, continuous monitoring system for finding methane leaks

from oil and gas operations

Caroline Alden1,2, Sean Coburn2, Robert Wright2, Esther Baumann3, Kevin Cossel3, Colm Sweeney4, Anna Karion3, Alex Rybchuk2, Kuldeep Prasad3, Ian Coddington3, Gregory Rieker2

1Cooperative Institute for Research in Environmental Sciences, 2University of Colorado,3National Institute of Standards and Technology, 4National Oceanic and Atmospheric Administration

Page 2: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

• Approach to methane monitoring• METEC oil & gas test site• Single-blind test results• Regional, continuous methane leak monitoring

2

Outline

Page 3: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

3

• Locate mobile spectrometer in a central location

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

Page 4: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

4

• Locate mobile spectrometer in a central location• Deploy retroreflective mirrors in field

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

Page 5: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

5

• Locate mobile spectrometer in a central location• Deploy retroreflective mirrors in field• Sequentially measure atmospheric CH4 along open paths

1+ km

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

Page 6: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

6

• Locate mobile spectrometer in a central location• Deploy retroreflective mirrors in field• Sequentially measure atmospheric CH4 along open paths• Determine species concentration

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

• < 5 ppb CH4 precision over 1+ km paths in 2 mins• Handles multi-species absorption interference• Water measured directly dry-air mole fractions• High stability over time, little to no instrument drift

Page 7: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

7

• Locate mobile spectrometer in a central location• Deploy retroreflective mirrors in field• Sequentially measure atmospheric CH4 along open paths• Determine species concentration, track variability through time

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

Dry

[CH

4]D

ry [C

O2]

[H2O

]

Page 8: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Approach to methane leak detection

8

• Locate mobile spectrometer in a central location• Deploy retroreflective mirrors in field• Sequentially measure atmospheric CH4 along open paths• Determine species concentration, track variability through time, couple with

atmospheric modeling and inversions

Coburn, Alden et al. Optica, 5 (2018)Alden, Coburn et al. AMT, 11 (2018)

Dry

[CH

4]D

ry [C

O2]

[H2O

]

Page 9: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

METEC oil & gas test site

9

METEC (Methane Emissions Technology Evaluation Center)

“Hollywood well set”: decommissioned equipment plumbed with controlled leaksCU Mobile Lab

Fort Collins, Colorado

Alden, Coburn et al,. In Prep

Page 10: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

METEC oil & gas test site

10

Spectrometer located >1 km away to the SW

METEC (Methane Emissions Technology Evaluation Center)

Fort Collins, Colorado

Alden, Coburn et al,. In Prep

Page 11: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

METEC oil & gas test site

11

Pad CPad B

Pad ADetection: is there a leak?

Attribution: where is the leak?

Quantification: how big is the leak?

Alden, Coburn et al,. In Prep

Page 12: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Pad A: 6/6 leaks detected at pad A

Pad B: 6/6 leaks detected at pad B

Pad C: 5/5 leaks detected at pad C1/1 false detection avoided

Single-blind test results: Detection

12

Pad CPad B

Pad A

✓✓

✓Alden, Coburn et al,. In Prep

Page 13: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Pad A

Single-blind test results: Attribution

13

Pad C

TANK

WELL

SEPARATOR

Pad B

TANK

WELLSEPARATOR

Orientation of pad C with respect to spectrometer made component-level detection difficult

Pad A: Sub-pad levelsub-pad identified in 6 of 6 cases

Pad B: Component-levelcomponent identified in 6 of 6 cases

Pad C: Component-levelcomponent identified in 2 of 5 cases

✓✓

Alden, Coburn et al,. In Prep

Page 14: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Single-blind test results: Quantification

14

Pad B

TANK

WELLSEPARATOR

Test 10

True leak 3.9 ± 2 scfh (0.7 kg/hr) leak from separator regulator flange

Leak estimate 3.5 ± 1 scfh (0.6 kg/hr) from separator house pressure-reducing valve

Beam 1

Beam 2 Beam 3

Beam 1Beam 2Beam 3Background estimate

Alden, Coburn et al,. In Prep

5-10 ppb enhancements measured over 3.7 hours

Page 15: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Single-blind test results: Quantification

15

Controlled rate (Blind Test)Estimated rate (Blind Test)Controlled rate (Ad Hoc, treated as blind)Estimated rate (Ad Hoc, treated as blind)

Device-level measurements suggest 90% of all emissions come from leaks > 135 scfh (2.5 kg/hr)!

Alden, Coburn et al,. In PrepBrandt et al., ES&T, 50 (2016)

Page 16: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Regional, continuous methane leak monitoring

16

Miller et al., 2013 PNAS

Continuous NOAA/GMD data provide nation-wide statistics

Continuousmonitoring of

emissionsacross large areas

Pétron et al., 2014 JGR

Campaigns provide snapshots, reconciliation of emissions estimates

Methane emissions from oil and gas intermittent, unpredictable, and heavy-tailed: a small fraction of sources cause most of the emissions (“super-emitters”)

“Missing Link”Continuous monitoring of many sites will provide critical, missing information

about time variability of emissions and distributions of “super-emitters”

Page 17: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Thank You

17

Contact [email protected]

Thank you to funding agenciesDOE ARPA-E https://arpa-e.energy.gov/DOE Office of Fossil Energy https://www.energy.gov/fe/office-fossil-energy

For more information about METEC site energy.colostate.edu/metec

Page 18: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Extra Slides

18

Page 19: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

19

Inte

nsity

0

Tooth spacing < 200 MHz (2 x 10-3 nm)

frequency

Equivalent to ~80,000 well-behaved continuous wave lasers

Spectral Bandwidth 179 – 187 THz (1600 – 1670 nm)

chosen here for methane

Frequency Comb Spectroscopy

Page 20: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

20

Two frequency comb lasers with slightly offset tooth spacing,give rise to a third comb in the radio frequency (rf) regime

Absorption feature

Optical Frequency (THz):Too fast to resolve on photodetector

Radio Frequency (MHz):Resolvable by photodetector

Dual Frequency Comb Spectroscopy

Rieker et al. Optica, 1 (2014)

Page 21: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

21

Absorption feature

Optical Frequency (THz):Too fast to resolve on photodetector

Radio Frequency (MHz):Resolvable by photodetector

Dual Frequency Comb Spectroscopy• Dry-air mole fractions CO2, CH4, H2O, HDO and 13CO2• Minimal to no instrument drift • Very high precision: < 5 ppb CH4 over 1 km path in 2-5 minutes• Measurement of long, open paths through the atmosphere (up to several km)

Rieker et al. Optica, 1 (2014)

Page 22: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Optical Frequency(THz)

RF Frequency(MHz)

fr fr

∆fr=fr - fr

E(ν)

Dual Frequency Comb Spectroscopy

Page 23: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

fr fr

∆fr=fr - fr

Optical Frequency(THz)

RF Frequency(MHz)

Dual Frequency Comb Spectroscopy

E(ν)

Page 24: Single-blind testing of a regional, continuous monitoring system for finding … · Single-blind testing of a regional, continuous monitoring system for finding methane leaks from

Frequency Comb Spectroscopy

24

t

Passively Mode-locked Laser

Time domain

Frequency domainI( f )

0

fo

With noise, output moves around...but basic comb structure is preserved.

Comb can only “translate” and “breathe”

frep

T=1 / frep

f

>100,000 well-behaved Continuous Wave lasers