simocode pro presentation for simodode dp customers share by voip.com.vn

24
System SIMOCODE pro

Upload: tran-thanh

Post on 21-Jun-2015

388 views

Category:

Technology


5 download

DESCRIPTION

Simocode pro presentation for simodode dp customers share by voip.com.vn

TRANSCRIPT

Page 1: Simocode pro presentation for simodode dp customers share by voip.com.vn

System

SIMOCODE pro

SIMOCODE pro

Page 2: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The System

SIMOCODE pro C – Compact

The compact system for:

Direct starters and Reversing starters

Up to 80 % of all present SIMOCODE-DP applications at a price reduction of 20 %.

Up to 80 % of all present SIMOCODE-DP applications at a price reduction of 20 %.

System

Page 3: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Control circuit Automation system

The Design of SIMOCODE pro Motor Feeders

Main circuit

Current Measuring Module

Connection

Cable

Basic Unit 1

SIMOCODE pro C – Compact

OperatorPanel*

*) Optional

System

Page 4: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The System

SIMOCODE pro V – Variable

The variable system with:

All control functions andVariably expandable additional functions

System

Page 5: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Design of SIMOCODE pro Motor Feeders

Main circuit

Connection

Cable

Basic Unit 2

Control circuit

SIMOCODE pro V – Variable

Automation system

OperatorPanel*+ Expansion

modules*

Current/VoltageMeasuring Module*

*) Optional

System

Page 6: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The System

has been designed for mixed operation.

Targeted combination of SIMOCODE pro C and SIMOCODE pro V in the same switchgear, depending on the individual functional

requirements

SIMOCODE pro C is fully upward-compatible with SIMOCODE pro V

A mixed application in the same switchgear does not produce extra costs – it saves costs!

A mixed application in the same switchgear does not produce extra costs – it saves costs!

No re-wiring is required (removable terminals)

The current measuring module can remain in the main circuit

No additional engineering is required (identical terminals)

The pro C parameterization can be adopted unchanged

pro V utilizes the same components as pro C (stock-keeping)

I.e. with a conversion to SIMOCODE pro V:

System

Page 7: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The System

Basic Unit Operator Panel

SIMOCODE pro C

Current Measuring Module

SIMOCODE-DP

Expansion modules

Digital Modules

Analog Module

Temperature

Module

Earth Fault

Module

SIMOCODE pro V

+ Voltage detection

System

Page 8: Simocode pro presentation for simodode dp customers share by voip.com.vn

The Components

SIMOCODE pro

SIMOCODE pro

Page 9: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Components

Connection CableIn various lengths(up to 2 m)

SIMOCODE pro C – Compact

Current Measuring Module

0.3 A – 630 AStraight-through/busbar connection technology

4 I / 3 O binaryThermistorPROFIBUS-DP24 V DC / 110 – 240 V UC

Basic Unit 1

Operator Panel5 buttons / 10 LEDs

Components

Page 10: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Components

Operator Panel5 buttons / 10 LEDs

Current Measuring Module Basic Unit 2

0.3 A – 630 AStraight-through/busbar connection technology

4 I / 3 O binaryThermistorPROFIBUS-DP24 V DC / 110 – 240 V UC

Connection CableIn various lengths (up to 2 m)

Current/VoltageMeasuring Module

0.3 A – 630 A /690 VStraight-through/busbar connection technology

SIMOCODE pro V – Variable

Expansion modules Additional binary I/Os 1 x 0/4 – 20 mA I/O 3 x sensors Pt100/ Pt1000 External earth fault via

summation current transformer

Components

Page 11: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

0.3 – 3 A2.4 – 25 A

10 – 100 A

20 – 200 A

63 – 630 A *)

The Current Ranges

Busbar connection

Straight-through transformer

0.3 A

or higher0.3 A

or higher

Current Measuring Modules for all motor currents

45 mm 55 mm 120 mm 145 mmWidths:

*) With 3UF18 intermediate transformers up to 820 A

Components

Page 12: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Voltage Range

0.3 – 3 A2.4 – 25 A/ 690 V

10 – 100 A/ 690 V

20 – 200 A/ 690 V

63 – 630 A*)/ 690 V

Busbar connection

Straight-through transformer

Up to 690 V

Up to 690 V

Current/Voltage Measuring Modules

*) With 3UF18 intermediate transformers up to 820 A

45 mm 55 mm 120 mm 145 mmWidths:

Components

Page 13: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Variably Expandable Additional Functions

Expansion modules for SIMOCODE pro V Up to 5 expansion modules can be connected to the

Basic Unit 2:

Digital Modules for: Max.2

Additional binary I/Os Bistable relay outputs Externally supplied inputs

(24 V DC or 110 – 240 V AC/DC)

Earth Fault Module for:Max.1

Expansion of the internal earth fault monitoring by a sophisticated external monitoring with summation current transformer

Components

Page 14: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Variably Expandable Additional Functions

Expansion modules for SIMOCODE pro V

Temperature Module for: Max.1

Temperature monitoring of up to 3 analog temperature sensors (e.g.: Pt100/ Pt1000)

New!New!

Analog Module for:Max.1

Input/output and monitoring of analog signals (0/4 – 20 mA) for, e.g., filling level/flowrate monitoring or the actuation of a display unit

New!New!

Components

Up to 5 expansion modules can be connected to the Basic Unit 2:

Page 15: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Smaller Dimensions

Including expanded functionality

67.5 mm

SIMOCODE pro

SIMOCODE-DP

96 mm

96 mm

36

mm

60

mm

Improved scalingaccuracy

All digital modulesare combinable

Additional functions

45 mm

70 mm

4 binary inputs3 relay outputsThermistorPROFIBUS DP

4 binary inputs4 relay outputsThermistorPROFIBUS DP

90 mm

140 mm

12 binary inputs7 relay outputsThermistorPROFIBUS DP

12 binary inputs8 relay outputsThermistorPROFIBUS DP

Components

Page 16: Simocode pro presentation for simodode dp customers share by voip.com.vn

The Functions

SIMOCODE pro

SIMOCODE pro

Page 17: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Functions

Comprehensive motor feeder protection + flexible control!

SIMOCODE pro integrates the following

features in only one system:

Multifunctional electronic motorprotection

Flexible software for motor control

Detailed operating, service and diagnostics data

Communication via PROFIBUS-DP

SIMOCODE pro is a flexible and modular motor management system for motors used in low-voltage applications.

Based on SIMOCODE-DP.

Functions

Page 18: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Functions

Functions

Protective functions

Overload protection (Class 5 - 40) Thermistor motor protection Phase failure monitoring Unbalance protection Stall protection Earth-fault monitoring Monitoring of current limit values Monitoring of operating hours Monitoring of motor stop times Number-of-starts monitoring Etc.

Expanded monitoring functions:

Temperature monitoring Pt100/ Pt1000 Voltage monitoring Power monitoring Cos-phi monitoring Phase sequence detection Input, output and monitoring 0/4-20 mA signal

Measuring curves recording

Control functions

Direct online starter Reversing starter Star-delta starter Star-delta starter with

reversal of rotational direction Two speeds, motors with separate windings

(pole changeover switch), also with reversal

of rotational direction Two speeds, motors with separate Dahlander

windings, also with reversal of rotational

direction Solenoid valve actuation Positioner actuation Soft starter actuation Soft starter actuation with reversal

of rotational direction Logic modules (truth tables, counters, timers,

edge evaluation, limit monitoring...) and Standard functions (power failure monitoring, emergency start, external faults ...)

More functions than ever before.

Page 19: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Functions

Functions

Protective functions

Overload protection (Class 5 - 40) Thermistor motor protection Phase failure monitoring Unbalance protection Stall protection Earth-fault monitoring Monitoring of current limit values Monitoring of operating hours Monitoring of motor stop times Numbers-of-starts monitoring Etc.

Expanded monitoring functions:

Temperature monitoring Pt100/ Pt1000 Voltage monitoring Power monitoring Cos-phi monitoring Phase sequence detection Input, output and monitoring

0/4-20 mA signal

Measuring curves recording

Control functions

Direct online starter Reversing starter Star-delta starter Star-delta starter with

reversal of rotational direction Two speeds, motors with separate windings (pole changeover switch), also with reversal

of rotational direction Two speeds, motors with separate Dahlander

windings, also with reversal of rotational

direction Solenoid valve actuation Positioner actuation Soft starter actuation Soft starter actuation with reversal

of rotational direction Logic modules (truth tables, counters, timers,

edge evaluation, limit monitoring...) and Standard functions (power failure monitoring, emergency start, external faults ...)

What‘s New.

Page 20: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Data

Functions

Service data

 Motor operating hours Motor stop times Number of motor starts Number of overload trips Unit-internal storage of comments Unit operating hours Etc.

Operating data

Motor switching state (on, off, left, right, slow, fast)

Current in phase 1, 2, 3 and max. current Voltage in phase 1, 2, 3 Effective power Apparent power Power factor Phase unbalance Phase sequence Time to trip Motor model heating Remaining motor cooling time Temperature (e.g. motor temperature) Current analog signal value Etc.

Diagnostics data

 Numerous detailed early warning and fault

messages, also for further processing within

the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable

status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the

main current circuit after ON control command) Etc.

Communication

12 Mbps , automatic baud rate detection Time synchronization Cyclic and acyclic services

Even more detailed information on the motor feeder.

Page 21: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

The Data

Functions

Service data

 Motor operating hours Motor stop times Number of motor starts Number of overload trips Unit-internal storage of comments Unit operating hours Etc.

Operating data

Motor switching state (on, off, left, right, slow, fast)

Current in phase 1, 2, 3 and max. current Voltage in phase 1, 2, 3 Effective power Apparent power Power factor Phase unbalance Phase sequence Time to trip Motor model heating Remaining motor cooling time Temperature (e.g. motor temperature) Current analog signal value Etc.

Diagnostics data

 Numerous detailed early warning and fault

messages, also for further processing within

the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable

status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the

main current circuit after ON control command) Etc.

Communication

12 Mbps , automatic baud rate detection Time synchronization Cyclic and acyclic services

What‘s New.

Page 22: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Addressing Plug for assignment of PROFIBUS address without PC/ PG

Integration & Configuration

Small auxiliary equipment with large time-saving potentials.

Assignment of a PROFIBUS address to one or several

basic units within seconds.

Assignment of a PROFIBUS address to one or several

basic units within seconds.

Commissioning of a motor feeder within seconds.

Commissioning of a motor feeder within seconds.

Memory Module for

parameterization without PC/ PG

Integration

Page 23: Simocode pro presentation for simodode dp customers share by voip.com.vn

Information

SIMOCODE pro

SIMOCODE pro

Page 24: Simocode pro presentation for simodode dp customers share by voip.com.vn

Automation and Drives

SIMOCODE pro As of 09/04(This document is subject to changes)

Low-VoltageControls & Distribution

Starting Situation

System

Components

Functions

Integration

Practice

Information

Information

Information

Product brochure

System manual

Selection and ordering data

“Conversion flyer”

www.siemens.com/simocode