sikagrout 215
DESCRIPTION
Sikagrout 215 BrochuresTRANSCRIPT
-
ProductDataSheetEdition06,2003Identification no. GF01SikaGrout215
Sikagrout 215PumpableNon-ShrinkCementitiousGrout
Description SikaGrout215ifanon-shrinkselflevelling,cementitiousgroutingmortarwithextended working time to suit local ambient temperature.
Uses SikaGrout215issuitableforrepairstoconcretestructuresandthefollowinggroutingworkswithclearanceof10mmormore:nMachinefoundationsnRailbedsnColumnsinpre-castconstructionnConcreteanchorsnBridgebearingsnCavitiesnGapsnRecesses
Characteristics /Advantages
nHighlyearlystrengthnHighultimatestregthn Extended working timenDense,non-shrinkn Non-toxic, non-corrosivenChlorideandironfreen High final strength
1 SikaGrout-2151/2
Instruction for UseSurfacePreparation Surface Preparation
Concretesurfacesshouldbeclean,soundandfreefromoil,grease,cementlaitance and all loosely adhering particles. Metal surfaces (iron and steel) should befreefromscale,rust,oilandgrease.Absorbentsubstratesmustbesaturatedthoroughly,butthereshouldbenostandingwater.MixingThe pre-mixed powder is added to water to suit the desired consistency. For flowable consistency, approximately 4.2 litres of water per bag is required. Mix mechanically for 2-3 mins with a slow speed drill (max. 500 RPM) until a smooth evenconsistencyisachieved.ApplicationAfter mixing., allow the mortar to rest for a while, stirring lightly to ensure that airdisplayedbythegroutingisallowedtoescape.Whencarryingoutbaseplategrouting, ensure that sufficient pressure head is maintained to keep mortar flow uninterrupted. Make sure that the necessary formwork is firmly in place and kept water light. Sika Grout 215 may be placed in thickness up to a maximum of 50mm atonepour.Wherelargeareasaretobeplaced,itisimportanttomaintainacontinuous flow throughout. It is necessary to organize the work sequence properly (manpower, materials, etc.) to ensure an uninterrupted flow. In such large areas,SikaGrout215mayalsobepumped.Aheavydutydiaphragmpumpisrecommendedforthispurpose.Screwfeedandpistonpumpsmayalsobeused.Specific ApplicationGrouting under base plate: Use flowable consistencyGroutingAnchorbolts:UsetrowellableconsistencyGrouting large volumes: For sections thicker than 50mm it is necessary to filltheSikaGrout215withgraded10mmsiltfreeaggregatetominimizetemperaturerise. The quantity of aggregate should not exceed 1 part Sika Grout 215 by weight.For such mixes, a conventional concrete mixer and pump may be used.CleaningCleanalltoolsandequipmentwithwaterimmediatelyafteruse.Hardenedmortarcanonlybemechanicallyremoved.
Co
nst
ruct
ion
-
Important Recommendations
UseSikaGrout215forrepairstoconcretestructureandgroutingonly.MinimumGap:10mmMaximum Gap: 50mmMinimumApplicationTemperature:100CAttemperaturelowerthan200Csettingtimeandstregnthgainwillbeslower.Cure exposed mortar surface for at least 3 days with Anitsol E curing compoundoruseotherapprovedcuringmethods.
Coverage/Consumption(approx.)
SikaGroutWater (Litre) VolumeMortar
1.84kg0.311lit.
25kg4.213.6lit.
74 x 25 kg bag 3091m3
Performance Flow (British Standard Cone):280-320mmafter3minutes260-300mmafter30minutes(Keep on stirring slightly)Comprehensive Strength in MPa (N/mm2):(Water content: 4.2 liters/25 kg bag. Testing & storge at 25 0 C under water)1day :383days :457days :5528days:70
Technical Data
Color Grey
Form Powder
BulkDensity 1.64kg/l
WetDensity 2.10-2.20kg/l
StorageCondition Storeinadryplace
ShelfLife 15monthswhenunopened
Theinformation,and,inparticular,therecommendationsrelatingtotheapplicationandend-useofSikaproducts, are given in good faith based on Sikas current knowledge and experience of the products when properlystored,handledandappliedundernormalconditionsinaccordancewithSikasrecommendations.Inpractice,thedifferencesinmaterials,substratesandactualsiteconditionsaresuchthatnowarrantyin respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationshipwhatsoever,canbeinferredeitherfromthisinformation,orfromanywrittenrecommendations,orfromanyotheradviceoffered.Theuseroftheproductmusttesttheproductssuitabilityfortheintendedapplicationandpurpose.Sikareservestherighttochangethepropertiesofitsproducts.Theproprietaryrightsofthirdpartiesmustbeobserved.Allordersareacceptedsubjecttoourcurrenttermsofsaleanddelivery.UsersmustalwaysrefertothemostrecentissueofthelocalProductDataSheetfortheproductconcerned,copiesofwhichwillbesuppliedonrequest.
Legal Notice
Sika Philippines, Inc.UnitA&B888MarcosAlvarez,Ave.Talon,LasPiasCity1747Philippines
Tel.no. :8001818Fax. no : 806 2378www.sika.com.ph
2 SikaGrout-2152/2