sheet index kck fire department hq remodel fd … · 2012 international fire code 2009...

24
DN UP KCK FIRE DEPARTMENT HQ REMODEL KANSAS CITY KANSAS FIRE DEPARTMENT KANSAS CITY, KS CONSTRUCTION DOCUMENTS 07/01/2019 ARCHITECTURAL ARCHIMAGES, INC 14205 WEST 95TH STREET LENEXA, KS 66215 T: 913 - 378 - 9533 www.archimages - stl.com MEP/FP BRANCHPATTERN 7400 COLLEGE BOULEVARD, SUITE 150 OVERLAND PARK, KS 66210 T: 913 - 951 - 8311 PROJECT LOCATION SHEET INDEX SHEET NUMBER SHEET NAME PROJECT LOCATION OWNER & PROJECT ADDRESS KCK FIRE DEPARTMENT 815 NORTH 6TH STREET KANSAS CITY, KS 66101 ARMSTRONG AVE. N. 6TH STREET MINNESOTA AVE. N. 5TH STREET ANN AVE. N. 7TH STREET TRFY CODE INFORMATION GROUP FLOOR AREA B 890 S.F. REMODEL AREA 2ND FLOOR TOTAL GROSS AREA APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL RESIDENTIAL CODE 2012 UNIFORM PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2011 NFPA 70; NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE 2009 INTERNATIONAL ENERGY CODE 2012 INTERNATIONAL PROPERTY MAINTENANCE CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE TABLE 1004.1 OCCUPANT LOADS: GROUP REMODEL AREA AREA TABLE 1004.1.1 OCCUPANTS B 890 S.F. 100 GROSS PER PERSON 9 TOTAL RENOVATED SPACE OCCUPANT LOAD TABLE 1016.1 EXIT TRAVEL (NS) B 200 FEET (MAX.) 12,256 S.F. 9 71' - 8" (ACTUAL) 71'-8" LEGEND: RENOVATED SPACE EXIT TRAVEL DISTANCE MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IF SUBMITTED AS DESCRIBED IN THE PROJECT MANUAL. 0 8' 16' 32' 0 6" 1' 3" 0 1' 2' 6" 3" 0 6" 1' 2' 0 1' 2' 3' 0 1' 2' 4' 0 2' 4' 6' 0 2' 4' 8' 4' 0 8' 16' Project No. Date D B A 1 2 3 4 5 6 1 2 3 4 5 6 Sheet No. www.archimages- stl.com SCALE: 1/16" = 1'-0" SCALE: 1/8" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 3/8" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 1" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 3" = 1'-0" C Lenexa, Kansas 66215 14205 W. 95th Street p: [913] 378.9533 KS Architectural Corporation Archimages, Inc. # A-669 1 0 / 2 / 2 0 1 9 3 : 3 3 : 1 9 P M C : \ U s e r s \ a f l o r y \ a c a d \ K 1 9 5 0 3 - K C K F D H Q R e m o d e l _ C E N T R A L _ a f l o r y 8 F 8 X U . r v t G001 K19503 10/1/2019 COVER SHEET INVESTIGATIONS AND WOMEN'S LOCKER ROOM REMODEL Proposed: 815 N. 6TH STREET, KANSAS CITY, KANSAS U.G. PROJECT NUMBER BB29844 KANSAS CITY KANSAS FIRE DEPARTMENT HEADQUATERS PERMIT GENERAL G001 COVER SHEET ARCHITECTURAL A001 TYP NOTES, SYMB, & RULES A002 TYPICAL MOUNTING HEIGHTS A101 DEMOLITION PLAN A102 FLOOR PLAN A103 REFLECTED CEILING PLAN A104 ROOF PLAN A501 PARTITION TYPES & MISC. DETAILS A601 DOOR & FINISH SCHEDULES MECHANICAL/PLUMBING MP001 MECH./PLUMBING GENERAL LEGEND MP002 MECH./PLUMBING SPECIFICATIONS MECHANICAL/PLUMBING M101 HVAC SECOND FLOOR PLANS M501 MECHANICAL DETAILS P101 PLUMBING SECOND FLOOR PLANS P501 PLUMBING DETAILS P601 PLUMBING RISER DIAGRAMS MECHANICAL/PLUMBING MP701 MECH./PLUMBING SCHEDULES MECHANICAL/PLUMBING MEP101 MEP ROOF PLAN ELECTRICAL E001 ELECTRICAL GENERAL LEGEND E002 ELECTRICAL SPECIFICATIONS E101 ELECTRICAL SECOND FLOOR PLANS E501 ELECTRICAL DETAILS E601 ELECTRICAL RISER DIAGRAM E701 ELECTRICAL SCHEDULES SECOND FLOOR CODE PLAN N o . D a t e R e v i s i o n

Upload: others

Post on 25-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

DN

UP

KCK FIRE DEPARTMENT HQ REMODELKANSAS CITY KANSAS FIRE DEPARTMENTKANSAS CITY, KS

CONSTRUCTION DOCUMENTS 07/01/2019

ARCHITECTURAL

ARCHIMAGES, INC14205 WEST 95TH STREETLENEXA, KS 66215T: 913-378-9533www.archimages-stl.com

MEP/FP

BRANCHPATTERN7400 COLLEGE BOULEVARD, SUITE 150OVERLAND PARK, KS 66210T: 913-951-8311

PROJECT LOCATION

SHEET INDEX

SHEET NUMBER SHEET NAME

PROJECT LOCATION

OWNER & PROJECT ADDRESS

KCK FIRE DEPARTMENT 815 NORTH 6TH STREETKANSAS CITY, KS 66101

ARMSTRONG AVE.

N.

6T

H S

TR

EE

T

MINNESOTA AVE.

N.

5T

H S

TR

EE

T

ANN AVE.

N.

7T

H S

TR

EE

T T

RF

Y

CODE INFORMATION

GROUP FLOOR AREA

B 890 S.F.REMODEL AREA

2ND FLOOR TOTAL GROSS AREA

APPLICABLE CODES:2012 INTERNATIONAL BUILDING CODE2012 INTERNATIONAL RESIDENTIAL CODE2012 UNIFORM PLUMBING CODE2012 INTERNATIONAL MECHANICAL CODE2011 NFPA 70; NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE 2009 INTERNATIONAL ENERGY CODE2012 INTERNATIONAL PROPERTY MAINTENANCE CODE2012 INTERNATIONAL ENERGY CONSERVATION CODE

TABLE 1004.1 OCCUPANT LOADS:

GROUP

REMODEL AREA

AREA TABLE 1004.1.1 OCCUPANTS

B 890 S.F. 100 GROSS PER PERSON 9

TOTAL RENOVATED SPACE OCCUPANT LOAD

TABLE 1016.1 EXIT TRAVEL (NS)

B 200 FEET (MAX.)

12,256 S.F.

9

71'-8" (ACTUAL)

71'-8"

LEGEND:

RENOVATED SPACE

EXIT TRAVEL DISTANCE

MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IF SUBMITTED AS DESCRIBED IN THE PROJECT MANUAL.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

9 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

G001

K19503

10/1/2019

COVE

R SH

EET

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

PE

RM

IT

GENERAL

G001 COVER SHEET ■

ARCHITECTURAL

A001 TYP NOTES, SYMB, & RULES ■

A002 TYPICAL MOUNTING HEIGHTS ■

A101 DEMOLITION PLAN ■

A102 FLOOR PLAN ■

A103 REFLECTED CEILING PLAN ■

A104 ROOF PLAN ■

A501 PARTITION TYPES & MISC. DETAILS ■

A601 DOOR & FINISH SCHEDULES ■

MECHANICAL/PLUMBING

MP001 MECH./PLUMBING GENERAL LEGEND ■

MP002 MECH./PLUMBING SPECIFICATIONS ■

MECHANICAL/PLUMBING

M101 HVAC SECOND FLOOR PLANS ■

M501 MECHANICAL DETAILS ■

P101 PLUMBING SECOND FLOOR PLANS ■

P501 PLUMBING DETAILS ■

P601 PLUMBING RISER DIAGRAMS ■

MECHANICAL/PLUMBING

MP701 MECH./PLUMBING SCHEDULES ■

MECHANICAL/PLUMBING

MEP101 MEP ROOF PLAN ■

ELECTRICAL

E001 ELECTRICAL GENERAL LEGEND ■

E002 ELECTRICAL SPECIFICATIONS ■

E101 ELECTRICAL SECOND FLOOR PLANS ■

E501 ELECTRICAL DETAILS ■

E601 ELECTRICAL RISER DIAGRAM ■

E701 ELECTRICAL SCHEDULES ■

SECOND FLOOR CODE PLAN

No

.D

ate

Revis

ion

Page 2: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

AB

A

ANCHOR BOLT

ACT ACOUSTICAL CEILING TILE

ACP

AD

ACOUSTICAL CEILING PANEL

AREA DRAINADDL ADDITIONAL

ADH

ADDITIONAL

ADJ

ADHESIVE

ADJADJUSTABLE

AFF

ADJACENT

AFG

ABOVE FINISH FLOOR

AFSABOVE FINISH GRADE

AGGR

ABOVE FINISH SLAB

ALUM, AL

AGGREGATE

ALTALUMINUM

ANOD

ALTERNATE

APPROX

ANODIZED

ARCHAPPROXIMATE(LY)

ACS PNL ACCESS PANEL

ARCHITECT(URAL)

ASPH AT

AVG AVERAGE

BB

BBULLETIN BOARD

BD BOARD

BTWN

BLDG

BETWEEN

BUILDINGBM

BOT

BENCHMARK

BOTTOM

BITUM BITUMINOUS

BOS BOTTOM OF STEEL

BRG BEARINGBSMT BASEMENT

CAB

C

CABINET

CB CATCH BASIN

CCT

CG

CUBICLE CURTAIN TRACK

CORNER GUARD

CEM

CER

CEMENT, CEMENTITIOUS

CERAMIC

CCTV CLOSED CIRCUIT TELEVISION

CH BD CHALKBOARD

CI CAST IRON

CJ CONTROL JOINT

CL /

CLGCLR

CMU

CNTR

COL

CONC

CONFCONN

CONSTR

CONTCONTR

CORR

CSP

CSWK

CU

CW

CENTER LINE

CEILINGCLEAR

CONCRETE MASONRY UNIT

COUNTER

COLUMN

CONCRETE

CONFERENCECONNECTION

CONSTRUCTION

CONTINUOUSCONTRACTOR

CORRUGATED, CORRIDOR

COMBINATION STANDPIPE

CASEWORK

CUBIC

COLD WATER

D

DDEPTH

DBL DOUBLE

DBL ACT DOUBLE ACTINGDEG DEGREE

DEMO DEMOLISH

DEPT DEPARTMENTDET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONALDIFF DIFFUSER

DIM DIMENSION

DIM PT DIMENSION POINTDISP DISPENSER

DIST DISTANCE

DN DOWNDR DRAIN, DOOR

DS DOWNSPOUT

DSP DRY STANDPIPEDT DRAPERY TRACK

DW DISHWASHER

E

EEAST

EA EACH

EDR EQUIPMENT DRAWING

EG EDGE GUARDEIFS EXTERIOR INSULATION FINISH SYSTEM

EL ELEVATION

ELAST ELASTOMERICELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSUREENGR ENGINEER

EOS EDGE OF SLAB

EP ELECTRICAL PANELEPB ELECTRICAL PANEL BOARD

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EQ EQUALEQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENTESCAL ESCALATOR

EST ESTIMATE(D)

EWC ELECTRIC WATER COOLEREXC EXCAVATED

EXH EXHAUST

EXP EXPANSIONEXP JT EXPANSION JOINT

EXT EXTERIOR

F/F

FFACE TO FACE

FA FIRE ALARMFAS FIRE ALARM STATION

FB FLAT BAR

FCU FAN COIL UNITFD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATIONFEC FIRE EXTINGUISHER CABINET

FE FIRE EXTINGUISHER

FF FINISH FACE

FHC FIRE HOSE CABINET

FH/FEC FIRE HOSE / FIRE EXTINGUISHER CABINET

FHMS FLAT HEAD MACHINE SCREW

FHWS FLAT HEAD WOOD SCREWFHY FIRE HYDRANT

FLAM FLAMMABLE

FLASH FLASHINGFLEX FLEXIBLE

FLUOR FLUORESCENT

FO FACE OF

FSB FOLDING SHOWER BENCH

FSTNR FASTENER

FT FOOT, FEET

FTG FOOTINGFURN FURNITURE

FXTR FIXTURE

G

GGAS

H

HHIGH

GA GAUGE, GAGE

GAL GALLON

GALV GALVANIZED

GB GRAB BARGC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUMGL GLASS

GLU LAM GLUE LAMINATED

GLZ GLAZINGGR GRADE OR GRADING

GVL GRAVEL

GYP GYPSUMGYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

ID

IINSIDE DIAMETER

JAN

JJANITOR

KG

KKILOGRAM

L

LLENGTH, LONG

M

MMETERS

(N)

NNEW

OC

OON CENTER

PA

PPUBLIC ADDRESS

QT

QQUARRY TILE

R

RRISER

S SOUTH

T

TTREAD

VAC

VVACUUM

W

WWEST

XFMR

XTRANSFORMER

YD

YYARD

HB HOSE BIBBHC HOLLOW CORE

HD HEAD

HDBD HARDBOARDHDW,HDWR

HARDWARE

HDWD HARDWOOD

HGT, HT HEIGHTHM HOLLOW METAL

HNDRL HANDRAIL

HORIZ HORIZONTAL

HPT HIGH POINTHR HOUR

HVAC HEATING-VENTILATION-AIR CONDITIONING

IN INCH

INCAND INCANDESCENT

INCL INCLUDE, INCLUDINGINFO INFORMATION

INSUL INSULATION

INTR INTERIOR

INV INVERTIVT INTRAVENOUS TRACK

JST JOIST

JT JOINT

KIT KITCHEN

KPL KICK PLATE

KS KNEE SPACE

LAB LABORATORY

LAM LAMINATE, LAMINATIONLAV LAVATORY

LB POUND

LED LIGHT EMITTING DIODELF LINEAR FOOT

LG LENGTH

LIN LINEAR

LL LEAD LINEDLPT LOW POINT

LT LIGHT

LT WT LIGHT WEIGHTLTG LIGHTING

LVR LOUVER

HW HOT WATER

S

MACH MACHINE

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION SYSTEMMAX MAXIMUM

MB MACHINE BOLT

MC MEDICINE CABINETMDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MFR / MFG MANUFACTURER

MH MANHOLEMIN MINIMUM

MISC MISCELLANEOUS

MLDG MOLDINGMM MILLIMETERS

MO MASONRY OPENING

MOD MODULE, MODULAR

MTD MOUNTEDMTG MOUNTING

MVBL MOVABLE

MULL MULLION

NA NOT APPLICABLE

NAT NATURAL

NE NORTHEASTNIC NOT IN CONTRACT

NO NUMBER

NOM NOMINALNRC NOICE REDUCTION COEFFICIENT

NTS NOT TO SCALE

NW NORTHWEST

OA OVERALL

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED-CONTRACTOR INSTALLEDOFOI OWNER FURNISHED-OWNER INSTALLED

OPP OPPOSITE

ORD OVERFLOW ROOF DRAINOVHD OVERHEAD

OZ OUNCE

PART PARTIAL

PBD PARTICLEBOARD

PBX PRIVATE TELEPHONE EXCHANGEPCF POUNDS PER CUBIC FOOT

PCI POUNDS PER CUBIC INCH

PERF PERFORATED

PERIM PERIMETERPERM PERMANENT

PERP PERPENDICULAR

PI POINT OF INTERSECTIONPL PLATE

PLAM PLASTIC LAMINIATE

PLAS PLASTER, PLASTICPLBG PLUMBING

PLF POUNDS PER LINEAR FOOT

PLYWD PLYWOODPNEU PNEUMATIC

PNL PANEL

PNL BD PANEL BOARDPNT, P PAINT

PORT PORTABLE

PP PUSH PLATE

PPM PARTS PER MILLIONPR PAIR

PRCST PRECAST

PREP PREPARATIONPREFAB PREFABRICATION

PRKG PARKING

PROJ PROJECTPROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCHPT / PTD POINT, PAINT / PAINTED

PTN PARTITION

PTS PNEUMATIC TUBE STATIONPVC POLYVINYL CHLORIDE

PVG PAVING

PVMT PAVEMENT

PWR POWER

QTR QUARTERQTY QUANTITY

RA RETURN AIR

RAD RADIUSRB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLERD ROOF DRAIN

RECT RECTANGULAR

REF REFERENCEREFR REFRIGERATOR

REG REGISTER

REINF REINFORCE (D) (ING) (MENT)REQD REQUIRED

REQT REQUIREMENT

RESIL RESILIENT

RET RETURNREV REVISION

RF RESILIENT FLOORING

RH RIGHT HANDRHMS ROUND HEAD MACHINE SCREW

RHWS ROUND HEAD WOOD SCREW

RM ROOMRND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAYRWL RAIN WATER LEADER

SA SUPPLY AIR

SB SPLASH BLOCK

SC SOLID CORESCHED SCHEDULE

SCRN SCREEN

SD STORM DRAINSE SOUTHEAST

SECT SECTION

SEG SEGMENTSEP SEPARATION OR SEPARATE

SEP JT SEPARATION JOINT

SHT SHEET, SHEETINGSHWR SHOWER

SHV SHELVES, SHELVING

SIM SIMILAR

SK SINKSMS SHEET METAL SCREW

SP SPACE, SPACED, SPACING

SPEC SPECIFICATION

SPKLR SPRINKLERSPKR SPEAKER

SQ SQUARE

SS SANITARY SEWERSSK SERVICE SINK

SST STAINLESS STEEL

ST STREET

STA STATIONSTAG STAGGERED

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARDSTL STEEL

STOR STORAGE

STRUCT STRUCTURALSTS SELF-TAPPING STEEL

SUSP SUSPENDED

SUSP CLG SUSPENDED CEILINGSVCE SERVICE

SW SOUTHWEST

SYMM SYMMETRICALSYST SYSTEM

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVETC TOP OF CONCRETE, TOP OF CURB

TD TRENCH DRAIN

TEL TELEPHONETEMP TEMPORARY

THERM THERMAL

THK THICK, THICKNESSTHRES THRESHOLD

THRU THROUGH

TMPD GL TEMPERED GLASS

TO TOP OFTOR TOP OF RAILING

TOS TOP OF STEEL

TOT TOTALTOW TOP OF WALL

TP TOP OF PAVEMENT

TTB TELEPHONE TERMINAL BOARDTV TELEVISION

UC

UUNDER COUNTER

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTABLE POWER SUPPLYUR URINAL

VB VALVE BOX

VCT VINYL COMPOSITION TILEVERT VERTICAL

VEST VESTIBULE

VIT VITREOUSVP VENT PIPE

VOL VOLUME

VWC VINYL WALL COVERING

W/ WITHW/O WITHOUT

W/W WALL TO WALL

WC WATER CLOSET, WALL COVERING

WD WOODWDW WINDOW

WGL WIRE GLASS

WCHR WHEELCHAIR

WM WIRE MESHWO WHERE OCCURS

W/O WITHOUT

WPT WORKING POINT

WR WATER RESISTANTWSCT WAINSCOT

WSP WET STANDPIPE

WT WEIGHTWTHPRF WEATHERPROOF

WTRPRF WATERPROOF

WWF WELDED WIRE FABRICWWM WELDED WIRE MESH

CCR CARD CONTROL READER

BUR BUILT UP ROOFING SYSTEM

CT CERAMIC TILE

FRZ FREEZER

FRT FIRE RETARDANT TREATMENT

EX-BR EXISTING BRICK

ARCHITECTURAL ABBREVIATIONS

S

BO BOTTOM OF / BY OTHERSBMD BOTTOM OF METAL DECK

ACOUS/ACST

ACOUSTIC(AL)

& AND< ANGLE

ASPH ASPHALT

BLK / BLKG BLOCK / BLOCKING

[ CHANNEL

CLO CLOSET

CPT CARPET

CSK COUNTERSUNK

CRSC COLD ROLLED STEEL CHANNEL

CG CORNER GUARD

DK DECK

DTL DETAIL

DWG/DWGS DRAWING / DRAWINGS

EXIST, (E) EXISTING

EJ EXPANSION JOINT

FIN FINISH, FINISHED

FG FINISH GRADE

FLR FLOOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

MET, MTL METAL

N NORTH

OPNG OPENING

TPH TOILET PAPER HOLDER

TW TOP OF WALL

TRANS TRANSPARENT

UNF UNFINISHED

UTIL UTILITY

WAINS WAINSCOT

WP WATERPROOF

ARCHITECTURAL DIMENSIONING CONVENTIONS

D.

5.

DIMENSION, WHEN OCCURS

ALIGN

B.

C.

B.

A.

4.

3.

A.

F.

E.

D.

1.

2.

E.

C.

EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THEWORK AT THE "APPROXIMATE LOCATION SHOWN,"DO NOT SCALE DRAWINGS FOR DIMENSIONALINFORMATION.

ALL ELEMENTS OF THE DRAWINGS MAY NOT BEDRAWN TO EXACT SCALE. ALL DIMENSIONSREQUIRED ARE SHOWN (OR MAY BE DERIVEDFROM THOSE SHOWN OR NOTED) ON THE FLOORPLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,SCHEDULES, CONFIGURATION DETAILS, ANDSPECIFICATIONS. SEE THE NOTES BELOW FOR DIMENSIONING CONVENTIONS USED ON THIS PROJECT.

EXCEPT WHERE SPECIFICALLY NOTED TO THECONTRARY, ALL DIMENSIONS SHOWN ON THEARCHITECTURAL DRAWINGS CONFORM TO THEFOLLOWING CONVENTIONS:

DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL ARE MEASURED TO:

STRUCTURAL OR DIMENSIONAL GRID LINES.

CENTERLINE OF CONCRETE OR CONCMASONRY UNIT WALLS (EXCLUSIVE OFFURRING OR APPLIED FINISHES HAVINGTHICKNESS). REFER TO THE ARCH PLANSAND SECTIONS, THE STRUCT DRAWINGS,OR PARTITION SCHEDULE TO DETERMINETHE THICKNESS OF CONCRETE OR CONCMASONRY UNIT WALLS.CENTERLINE OF PARTITION ASSEMBLY(EXCLUSIVE OF ANY APPLIED FINISHESHAVING THICKNESS WHICH MAY BEADDED TO SUCH WALLS) AT PARTITIONSFRAMED WITH METAL STUDS. REFER TO"PARTITION SCHEDULE" TO DETERMINETHICKNESS OF EACH PARTITION TYPE.CENTERLINE OF DOOR, WINDOW, OR LOUVER OPENING.

CENTERLINE OF EQUIPMENT OR FURNISHING.CENTERLINE OF OTHER FEATURES AS INDICATED.

REFER TO ABBREVIATIONS LEGEND FOR SYMBOL USED TO INDICATE CENTERLINE DIMENSION.

DIMENSIONS UTILIZING THE "FACE OF"SYMBOL ARE MEASURED TO:

FACE OF CONCRETE OR CONC MASONRYUNIT WALL (EXCLUSIVE OF APPLIEDFINISHES HAVING THICKNESS OR FURRINGWHICH MAY BE ADDED TO THE FACE OFSUCH WALLS).

FACE OF PARTITION ASSEMBLY(EXCLUSIVE OF ANY APPLIED FINISHESHAVING THICKNESS WHICH MAY BEADDED TO SUCH WALL) AS DEFINEDBY THE PARTITION SCHEDULE.UNLESS NOTED AS A "FACE OFFINISH" OR "CLEAR" DIMENSION (SEENOTE 'E' BELOW), DIMENSIONS ARENOT MEASURED TO THE FACE OFAPPLIED FINISH. REFER TO THE"PARTITION SCHEDULE" TO DETERMINETHE THICKNESS OF EACH PARTITIONTYPE.INSIDE EDGE OF FINISHED DOOROPENING. REFER TO THE DOORSCHEDULE FOR ADDITIONALDIMENSIONAL INFORMATION.

DIMENSION OR WORK POINT AS INDICATED ON RELATED ARCH DETAIL PLAN, SECTION, ELEVATION, LAYOUT OR CONFIGURATION DETAIL, OR CONSTRUCTION DETAIL.

REFER TO ABBREVIATIONS LEGEND FOR SYMBOL USED TO INDICATE "FACE OF" DIMENSION.

WHERE "FACE OF FINISH" OR "CLEAR" DIMENSIONSARE SPECIFICALLY NOTED, THE DIM IS MEASURED TO:

FINISH FACES AT THE MOST NARROWOR CONSTRICTED POINTS OF SECTIONWHERE DIMENSION IS SHOWN, WHENTHE DIMENSION OCCURS ACROSS ANOPEN SPACE. THIS CASE, A "FACEOF FINISH" DIMENSION IS EQUIVALENTTO A "CLEAR" DIMENSION.

FINISH FACES AT THE WIDEST OR MOSTEXPANSIVE POINTS OF THE SECTION THEDIMENSION IS SHOWN WHEN THE DIMENSIONOCCURS ACROSS AN OBJECT OR GROUP OFOBJECTS.

WHERE "EQUAL" DIMENSIONS ARE USEDON REFLECTED CEILING PLANS TOLOCATE CEILING GRID WORK POINTS,MEASURE DIMENSIONS TO:

EDGE OF THE INDICATED CEILING ATTHE FACE OF THE ADJACENT APPLIEDFINISH MEASURED AT THE PLANE OFTHE CEILING.

CAUTION: DUE TO THE POSSIBLEAPPLICATION OF APPLIED FINISHES -THICKNESS OF WHICH MAY VARYBETWEEN FLOOR AND CEILING AND ISNOT ACCOUNTED FOR (EXCEPT ASINDICATED BY "FOF" OR "CLEAR") BYTHE DIMENSION SHOWN ON THE FLOORPLANS - THE CONTRACTOR MUSTADJUST, AS NECESSARY, THE FLOORPLAN DIMENSIONS TO REFLECT THEACTUAL DIMENSIONS FOUND AT PLANEOF THE CEILING.

WHERE DIMENSIONS ARE NOT PROVIDED ONFLOOR PLANS TO LOCATE DOOR OPENINGS,APPLY THE FOLLOWING RULES, IN ORDER, TODETERMINE THE LOCATION OF DOOR OPENINGS:

DOOR OPENINGS MAY BEDIMENSIONED ON DRAWINGS OTHERTHAN THE FLOOR PLANS. REFER TOTHE SECTIONS, ELEVATIONS, DETAILS,AND DOOR SCHEDULE NOTES FORADDITIONAL DIMENSIONAL INFORMATION.

WHERE THE HINGE-SIDE OF A DOOR ISSHOWN ADJACENT TO A WALL - OR WALLS- PERPENDICULAR TO THE WALL IN WHICHTHE DOOR OPENING OCCURS:

AT DOORS OCCURRING IN METAL FRAMEDGYPSUM BOARD PARTITIONS, LOCATE THEHINGE-SIDE OF THE DOOR FINISHEDOPENING 4 INCHES FROM THE FACE(EXCLUSIVE OF APPLIED FINISHES) OF THETHE CLOSEST PERPENDICULAR WALL ORPARTITION ASSEMBLY.

AT DOORS OCCURRING IN WALLS OF CONCMASONRY UNIT CONSTRUCTION, LOCATETHE HINGE-SIDE OF THE DOOR FINISHEDOPENING 10 INCHES FROM THE FACE(EXCLUSIVE OF APPLIED FINISHES) OF THETHE CLOSEST PERPENDICULAR WALL ORPARTITION ASSEMBLY.

WHERE DOOR OCCURS NOT ADJACENT TO APERPENDICULAR WALL AND EITHER "DIM E"OR "DIM F" IN DIAGRAM BELOW IS 16'-0" OR LESS, LOCATE DOOR UTILIZING THE FOLLOWING MINIMUM DIMENSIONS:

DIMENSION A = 18 INCHES MIN

DIMENSION B = 12 INCHES MIN

DIMENSION C = DOOR WIDTH + 2INCHES MINIMUM

DIMENSION D = 4 INCHES MIN ATMETAL FRAMED GYP BD PARTITIONSOR - EVEN MULTIPLE OF 1/2 CMUMODULE PLUS 2 INCHES AT CONCMASONRY UNIT WALLS

DIMENSIONS E AND F = AS SHOWN ON PLANS

DIMENSION G = 36 INCHES MIN

DIMENSION H = 60 INCHES MIN

IF SPACE ALLOWS, CENTER DOOR INWALL SHOWN ON THE DRAWINGS SOTHAT EITHER "DIM A" EQUALS "DIM C"OR "DIM B" EQUALS "DIM D".

IF "DIM E" IN DIAGRAMS BELOW IS LESSTHAN THE SUM OF 2 TIMES THE DOORWIDTH PLUS 20 INCHES, LOCATE DOORSO THAT MINIMUMS STATED BY NOTENO 4C ABOVE FOR "DIM A", "DIM B,"AND "DIM D" ARE MET - MAXIMIZING"DIM A" AND MINIMIZING "DIM D" TOTHE EXTENT POSSIBLE.

WHERE DOOR IS SHOWN LOCATED IN ALARGE EXPANSE OF OPEN WALL ("DIME" AND "DIM F" IN DIAGRAM BELOWBOTH EXCEED 16'-0"), PLACE DOORAT APPROXIMATE LOCATION SHOWN ONTHE PLANS. WHERE DOOR OCCURS INCMU WALL, PLACE DOOR ATAPPROXIMATE LOCATION SHOWN WHILEMINIMIZING "CUT" OR PARTIAL CMUMODULES ADJACENT TO THE JAMBS.

WHERE WALLS AND/OR PARTITIONS OFUNEQUAL THICKNESS ABUT, ALIGN EXPOSEDFACES, UNLESS OTHERWISE NOTED.

MEASURED AT CLG PLANE

"EQUAL" DIM AT CEILING

MEASURED TO FACE OF PTN

TYPICAL DIM ON CEILING PLAN

4"

4"

10"

10"

DIM E > 16'-0"

DIM F > 16'-0"

E

A

E

A D

B D B

E

A C

F

B D

G

H

NOTE NO 3 CONTINUED: NOTE NO 4 CONTINUED:

SECOND LEVEL

+10'-0"

WALL SECTION

WALL SECTION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

BUILDING SECTIONWALL SECTION NUMBER

90°

NEW GRIDIDENTIFICATION

EXISTING GRIDIDENTIFICATION

LAYOUT GRID LINES

SHEET WHERE DRAWN

DIRECTION OF VIEW

LEVEL LINE

REVISION EXTENT

ROOM NAME AND NUMBER

DETAIL REFERENCE

SECTION DETAIL REFERENCEEXTERIOR ELEVATION

A102 2

1

1

2

INTERIOR ELEVATION REFERENCE

SEE PARTITION SYMBOL DESCRIPTION ON PARTITION TYPE SHEET

PARTITION TYPE IDENTIFICATION MARK

SHEET WHERE DRAWN

ELEVATION NUMBER ANDDIRECTION OF VIEW

SHEET WHERE DRAWN,HYPHEN INDICATES DETAILON SAME SHEET.

DETAIL NUMBER

SHEET WHERE DRAWN

ELEVATION NUMBER ANDDIRECTION

WINDOW AND LOUVER TYPE MARK

SEE CORRESPONDING NUMBER ON SCHEDULE

NAME OF LEVEL

INDICATES HEIGHT ABOVE PROJECT DATUM

EXTENT OF CURRENT REVISION

KEYED NOTE MARK

MATCH LINE REFERENCE

DRAWING TITLE SYMBOLS

SEE CORRESPONDING NUMBERED LEGEND ON SHEET WHERE REFERENCE OCCURS

DRAWING INDICATION

A B

1

SCALE:1

A101

A1011

1

A101

A101

1

A10

1

Room Name

101

W-X

B3A

1 View Name1/8" = 1'-0"

A104

A102

A10

3

3

DRAWING TITLE

DRAWING SCALE

DRAWING NUMBER

1REVISION TAG MARK

SEE CORRESPONDING NUMBERED LEGEND ON SHEET WHERE REFERENCE OCCURS

E01

EQUIPMENT/ACCESSORY IDENTIFICATION MARK

1 / A101

ELEVATION NUMBER

SHEET WHERE DRAWN

ELEVATION DIRECTION

TYPICAL ARCHITECTURAL REFERENCE SYMBOLS

SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION

101

DOOR IDENTIFICATION MARK21 4 5

GENERAL NOTESGENERAL NOTES_1W X 2H

GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS & TESTING REQUIRED FOR COMPLETE RELATED WORK. THE GENERAL CONTRACTOR SHALL ALSO BE IN CHARGE OF THE OPERATION FROM THE TIME OF COMMENCEMENT UNTIL THE COMPLETION OF WORK AND TO WHOM ALL ORDERS AND DIRECTIONS SHALL BE GIVEN.

ALL TRADES SHALL BE RESPONSIBLE TO READ ALL DRAWINGS, DETAILS, & PLANS ASSOCIATED WITH ALL PACKAGES INCLUDING ARCHITECTURAL & MEP ASSOCIATED WITH THIS PROJECT TO ENSURE PROPER COORDINATION. IF ANY CONFLICTS EXIST, THAT TRADE SHALL NOTIFY THE CONTRACTOR OF THE SAME PRIOR TO CONSTRUCTION WHO SHALL IN TURN NOTIFY THE G.C.

CONTRACTOR SHALL DIRECT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION, AND CONTRACTOR SHALL BE RESPONSIBLE FOR ANY WORK WHICH PROCEEDS WITHOUT DUE COURSE AND COORDINATION.

ALL MATERIALS SHOWN OR CALLED FOR ON THESE CONSTRUCTION DOCUMENTS TO BE NEW AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS.

ALL INTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.

NO BACK TO BACK JUNCTION BOXES SHALL BE PERMITTED IN SOUND PARTITIONS.

CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH ALL APPLICABLE BUILDING CODES, LOCAL RULES AND REGULATIONS, AND ALL OTHER CODES, REGULATIONS AND GOVERNING AGENCIES HAVING JURISDICTION WITH ALL APPLICABLE AMENDMENTS UNLESS ALTERED OR CHANGED THROUGH VARIANCES OF OTHER LEGAL PROCEDURES.

COORDINATE ALL CONSTRUCTION PRIOR TO BEGINNING WORK AND SUBMIT PROPOSED WORK SCHEDULE TO THE OWNER & ARCHITECT FOR APPROVAL.

UNLESS OTHERWISE INDICATED, THE CONTRACT SCOPE INCLUDES ALL MATERIALS AND EQUIPMENT ON THE DRAWINGS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SMOKE DETECTORS, EXIT SIGNS, EMERGENCY LIGHT AND FIRE ALARM SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES.

NOT USED

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

FIELD VERIFY ALL EXISTING DIMENSIONS.

12.

MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IF SUBMITTED AS DESCRIBED IN THE PROJECT MANUAL.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

1 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A001

K19503

10/1/2019

TYP

NOTE

S, S

YMB,

& R

ULES

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

No

.D

ate

Revis

ion

Page 3: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

CLINIC SINK

FINISH FLOOR

ACCESSORY TYPE

COMMENTS WALL MOUNTED

CA

BIN

ET

INT

ER

IOR

60"

TO

TO

P O

F

FIRE EXTINGUISHER

CABINET

FINISH FLOOR

ACCESSORY TYPE

COMMENTS

WALL MOUNTED HANDRAIL

TO

TO

P

36"

OR ELEV

SEE PLAN

WALL CLOCK

78"

FABRIC COVERED TACK BOARD

48"

- U.N

.O.

U.N

.O.

30"

MARKER BOARD

48"

- U.N

.O.

U.N

.O.

30"

OR ELEV

SEE PLAN

OR ELEV

SEE PLAN

72"

U.N

.O.

MOP & BROOM HOLDER

SEMIRECESSED

SURFACE MOUNTED

SURFACE MOUNTED

SURFACE MOUNTED

SURFACE MOUNTED

SURFACE MOUNTED

48"

AT

AC

CE

SS

IBLE

60"

ROBE HOOK

SURFACE MOUNTED

40"

U.N

.O.

SPECIMEN PASS-THRU

THRU-WALL MOUNTED

TOP OF COUNTER

SE

E IN

T E

LEV

VA

RIE

S

SOAP DISPENSER

SURFACE MOUNTED

TO

SLO

T

10"

PAPER TOWEL DISPENSER

SURFACE MOUNTED

ALCOHOL DISPENSER

SURFACE MOUNTED

MISCELLANEOUS ACCESSORY TYPICAL MOUNTING HEIGHTS

TO

SP

OU

T

10"

TO

SP

OU

T

48"

MA

X

26"

U.N

.O.

48"

U.N

.O.

SHARPS CONTAINER

SURFACE MOUNTED

48"

MA

X

ELAPSED TIME CLOCK

SURFACE MOUNTED

4'-1

1 31

/32"

U.N

.O.

FILMILLUMINATOR

SURFACE MOUNTED

48"

U.N

.O.

OTOSCOPE

SURFACE MOUNTED

48"

U.N

.O.

SPHYGMOMAN-OMETER

SURFACE MOUNTED

TO

OP

EN

ING

48"

U.N

.O.

GLOVE BOX

SURFACE MOUNTED

HEALTHCARE ACCESSORY TYPICAL MOUNTING HEIGHTS

CLOSET HANGAR ROD

& SHELF

FINISH FLOOR

ACCESSORY TYPE

COMMENTS WALL MOUNTED

MISCELLANEOUS ACCESSORY TYPICAL MOUNTING HEIGHTS

60"

48"

MA

X

WALL PHONE

SURFACE MOUNTED

TELEPHONE HOUSING

SURFACE MOUNTED

TO

CO

IN S

LOT

48"

48"

MA

X

CUP DISPENSER

SURFACE MOUNTED

WALL SWITCH

SURFACE MOUNTED

48"

MA

X

SURFACE MOUNTED

MIN

18"

RECEPTACLE/TELEPHONE/

DATA

SURFACE MOUNTED

VA

RIE

S8"

TOP OF COUNTER

TELEPHONE OUTLET

SURFACE MOUNTED

48"

MA

X

RECEPTACLE/TELEPHONE/

DATA

SURFACE MOUNTED

ELEVATOR CALL BUTTON

35"

- 48

"

72"

ELEVATOR VISIBLE SIGNAL

INDICATOR

SURFACE MOUNTED

TACTILE CHARACTER INDICATOR

SURFACE MOUNTED

60"

40"

PANIC BAR

SURFACE MOUNTED

DOORPULL

SURFACE MOUNTED

DOORLATCH

SURFACE MOUNTED

42"

U.N

.O.

40"

48"

U.N

.O.

MED-GAS SHUT OFF

SURFACE MOUNTED

40"

ADA DOOR OPERATOR

VARIES

TO

PU

LL

48"

MA

X

MANUAL FIRE PULL

SURFACE MOUNTED

84"

FIRE STROBE/LIGHT/AUDIBLE ALARM

SURFACE MOUNTED

12"

WALL MOUNTED EXIT SIGN

WALL MOUNTED

LINE OF CEILING

2"

EQ EQ

EXIT

EXIT

4"MOUNT ON STRIKE SIDE ALIGNED WITH TOP OF DOOR FRAME WHEN DIM ABOVE DOOR HEAD < 12"

CENTER 2" ABOVE DOOR FRAME WHEN DIM ABOVE DOOR HEAD IS >/= 12"

SURFACE MOUNTED

SPECIALTY EQUIP(IE. THERMOSTAT,CARD

READER,INTERCOM)

48"

MA

X

PAPER TOWEL DISPENSER

FINISH FLOOR

ACCESSORY TYPE

COMMENTS SURFACE MOUNTED

TO

DIS

P S

LOT

48"

MA

X

TOILET ACCESSORY TYPICAL MOUNTING HEIGHTS

TOILET TISSUE DISPENSER

SURFACE MOUNTED

24"

TO

DIS

P S

LOT

44"

PAPER TOWEL DISPENSER &

TRASH RECEPTACLE

SEMIRECESSED

SANITARY NAPKIN

DISPOSAL

SURFACE MOUNTED

30"

TO

SP

OU

T

40"

VANITY SOAP DISPENSER

SURFACE MOUNTED

33"

MA

X

DAIPER CHANGING STATION

SURFACE MOUNTED

FRAMED VANITY MIRROR

SURFACE MOUNTED

40"

MA

X

SINK

POWER HAND DRYER

SURFACE MOUNTED

TO

BU

TT

ON

48"

MA

X

FINISH FLOOR

ACCESSORY TYPE

COMMENTS

PLUMBING FIXTURE TYPICAL MOUNTING HEIGHTS

FINISH FLOOR

ACCESSORY TYPE

COMMENTS

GRAB BAR TYPICAL MOUNTING HEIGHTS & TOILET ACCESSORY PLANS

34"

SHOWER STALL GRAB BAR

SURFACE MOUNTED

ROLL-IN SHOWER STALL GRAB BAR

SURFACE MOUNTED

34"

TOILET

WALL/FLOOR MOUNTED

17"-

19"

URINAL

WALL MOUNTED

24"

TY

P

AC

CE

SS

I BLE

17"

MA

X A

T

SANITARY NAPKIN

DISPENSER

RECESSED& SURFACE

40"

U.N

.O.

CO

UN

TE

R H

T

34"

SOAP DISPENSER

COUNTERTOP MOUNTED

40"

U.N

.O.

SHOWER MIXING VALVE

WALL MOUNTED

78"

U.N

.O.

SHOWER HEAD

WALL MOUNTED

34"

LAVATORY

WALL MOUNTED

34"

LAVATORY

COUNTER MOUNTED

CHILDREN'S DRINKING FOUNTAIN

WALL MOUNTED

DOUBLE DRINKING FOUNTAIN

WALL MOUNTED

TO

SP

OU

T

36"

MA

X

TO

SP

OU

T

30"

MA

X

TO

SP

OU

T

38"

- 43

"

SINGLE DRINKING FOUNTAIN

WALL MOUNTED

TO

SP

OU

T

36"

HAND HELD SHOWER

WALL MOUNTED

78"

U.N

.O.

18"

FOLDING SHOWER SEAT

SURFACE MOUNTED

34"

8"18

"

34"

36"

6" 12"42"

42"

ADA TOILET GRAB BAR

SURFACE MOUNTED

12"

58"

15"

TOILET PARTITION

12"

48"

URINAL SCREEN

WALL MOUNTED

WALL MOUNTED

18"

8"

21" 12

"42

"

TOILET PAPER

SANITARY NAPKIN DISPOSAL

ADA GRAB BARS

6" 36"

TYPICAL ACCESSORIES AT

ACCESSIBLE TOILET

NOTE: SANITARY NAPKIN DISPOSAL AT WOMEN'S & UNISEX ONLY

WALL HUNG COMPUTER

SURFACE MOUNTED

30"

U.N

.O.

72"

U.N

.O.

DATADUPLEX

ROTATE HORIZONTAL IF 42" H. COUNTER IS ABOVE

36" H. U.N.O

NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT

NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT

NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT

NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT

NOTE: SOME OBJECTS INDICATED HERE ARE NOT INCLUDED IN THIS PROJECT

DIM ON PLANDIM

ON

PLA

N

WHEN COMPLETELY DIMENSIONED ON REFLECTED CEILING PLAN

RULE 1

LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED BY A REFLECTED CEILING PLAN, ENLARGED REFLECTED CEILING PLAN, OR DETAIL.

SPECIFIC DIMENSIONS SHOWN BY REFLECTED CEILING PLANS, ELEVATIONS, OR DETAILS TAKE PRECEDENCE OVER TYPICAL LOCATION RULES.

A. THE A-SERIES DRAWINGS ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND LOCATION OF ALL EXPOSED ELEMENTS. THE A-SERIES DRAWINGS TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND LOCATION OF ALL PARTS OF THE WORK.

1. SPECIFICALLY AND INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR NOTATION ON THE ARCHITECTURAL DRAWINGS.

2. OCCURRING WITHIN A ROOM OR OTHER IDENTIFIABLE SPACE FOR WHICH ARCH SHEET OR SCHEDULE NOTES INDICATE THAT DIMENSIONS PROVIDED ELSEWHERE SHALL GOVERN.

B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE THE TYPICAL RULES WHICH GOVERN THE LOCATION, CONFIGURATION IN RELATIONSHIP TO OTHER ELEMENTS OF THE WORK, AND FINISHED ALIGNMENT OF ALL ITEMS OCCURRING ON REFLECTED CEILING PLANS OF THE PROJECT.

C. THE A-SERIES FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, ELEVATIONS, AND DETAILS ILLUSTRATE THE DIMENSIONED LOCATION OF MANY - BUT NOT ALL -EXPOSED PARTS OF THE WORK. APPLY THE RULES ON THIS SHEET - IN ORDER - TO DETERMINE THE LOCATION OF EXPOSED PART OF THE WORK.

1. WHEN UNIQUELY AND SPECIFICALLY DIMENSIONED ON THE A-SERIES PLANS, SECTIONS, OR ELEVATIONS (OR COMBINATION THEREOF), LOCATE AS DIMENSIONED.

2. IF NOT SHOWN, OR IF SHOWN BUT NOT DIMENSIONED, BY THE A-SERIES PLANS OR ELEVATIONS, LOCATE AS INDICATED BY THE APPLICABLE RULE.

D. REFER TO THE "ARCHITECTURAL GENERAL NOTES" FOR ADDITIONAL NOTES WHICH MAY BE APPLICABLE TO THE WORK SHOWN ON THIS SHEET.

WHEN NOT DIMENSIONED BUT SHOWN CENTERED

RULE 2

EQUAL

EQ

UA

LE

QU

AL

EQUAL

LOCATE ITEMS CENTERED IN SPACE (OR CEILING PLANE) WHEN SHOWN (BUT NOT DIMENSIONED) VISUALLY AT APPROXIMATE CENTER OF SPACE.

WHEN OFF-CENTER IN SPACE BUT CENTERED ON ADJACENT FEATURE

RULE 3

EQUAL

EQ

UA

LE

QU

AL

EQUAL

LOCATE ITEMS CENTERED ON ADJACENT OPENING OR FEATURE WHEN SHOWN (BUT NOT DIMENSIONED) OFF-CENTER IN OVERALL SPACE BUT CENTERED AGAINST ADJACENT FEATURE.

WHEN ALIGNED WITH OTHER FEATURES

RULE 4

LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC) ALIGNED WITH ADJACENT ITEMS FOR WHICH DIMENSIONS OR RULES ARE PROVIDED. VISUAL ALIGNMENT IS CRITICAL. THE CONTRACTOR SHALL SELECT ONE ITEM IN EACH LINE (ON BASIS OF TOLERANCES, SEQUENCE OF CONSTRUCTION, TRADE, OR OTHER CRITERIA) TO SERVE AS THE BENCHMARK FOR EACH ALIGNMENT.

LOCATION (IN THIS DIRECTION) OF ONE ITEM IN LINE IS ESTABLISHED BY DIMENSION OR OTHER RULE (RULE NO 3 SHOWN).

ACTUAL LINE OF ALIGNMENT DETERMINED BY SELECTING ONE ITEM AS BENCHMARK; OTHER ITEMS ARE LOCATED TO ALIGN WITH BENCHMARK ITEM. SPACE EQUALLY.

ALIGND

IM O

N P

LAN

ALIGN WITH FEATURES SHOWN DIMENSIONED ELSEWHERE IN SPACE

RULE 5

LOCATE ITEMS ALIGNED WITH OTHER ITEMS SHOWN DIMENSIONED ELSEWHERE IN SPACE (OR CEILING PLANE).

DIM ON PLAN

LOOK FOR DIMENSIONS OR NOTES SHOWN IN LINE BEYOND

DIM

ON

PLA

N

LOCATE FEATURES SYMMETRICALLY

RULE 6

LOCATE ITEMS ALIGNED WITH OTHER ITEMS SHOWN DIMENSIONED ELSEWHERE IN SPACE (OR CEILING PLANE).

CENTERLINES OF SPACE OR PLANE

DIM ON PLAN

EQUAL EQUAL

EQ

UA

LE

QU

AL

EQUAL EQUAL

EQ

UA

LE

QU

AL

LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC) AT CENTER OF OF PANEL ON SQUARE GRID-TYPE CEILINGS

WHEN NOT DIMENSIONED BUT OCCURS ON A SQUARE GRID-TYPE CEILING

RULE 7

1X EQUAL 3X EQUAL

EQ

UA

LE

QU

AL

LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC) AT CENTER OF SHORT DIRECTION OF RECTANGULAR PANEL; LOCATE AT 1/4, 1/2, OR 3/4 POINT OF LONG DIRECTION OF RECTANGULAR PANEL

WHEN NOT DIMENSIONED BUT OCCURS ON A RECTANGULAR GRID-TYPE CEILING

RULE 8

EQUAL EQUAL

FOR MANY SPACES, THE ARCHITECTURAL REFLECTED CEILING PLANS ESTABLISH AN IDEAL PATTERN FOR LOCATING SPRINKLER HEADS. IN SPACES WHERE HEADS ARE SHOWN, FOLLOW PATTERN ESTABLISHED BY THE DRAWINGS. WHERE ADDL HEADS ARE REQUIRED TO CONFORM WITH CODE, PROVIDE HEADS IN GENERAL CONFORMITY WITH PATTERN ESTABLISHED BY THE DRAWINGS.

IN SPACES WHERE SPRINKLER HEADS ARE NOT SHOWN BY THE ARCHITECTURAL REFLECTED CEILING PLANS, PROVIDE HEADS AS REQUIRED BY CODE.

TYPICAL RULES FOR DETERMINING REFLECTED CEILING PLAN LOCATIONS, DIMENSIONS, AND CONFIGURATIONS

LOCATE SPRINKLER HEADS WITHIN 3" DIAMETER OF IDEAL POINT DIMENSIONED (OR SHOWN BY RULE) ON REFLECTED CEILING PLAN.

E.

F.

GENERAL NOTES

LOCATE SPRINKLER HEADS WITHIN 3" DIAMETER OF IDEAL POINT DIMENSIONED (OR SHOWN BY RULE) ON REFLECTED CEILING PLAN.

EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON ON DRAWINGS OF OTHER DISCIPLINES SHALL GOVERN ONLY WHERE:

NOTE: THE INFORMATION PROVIDED ON THIS SHEET IS PROVIDED AS GENERAL REFERENCE INFORMATION. SOME OF THIS DATA MAY NOT BE APPLICABLE TO THIS PROJECT.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

2 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A002

K19503

10/1/2019

TYPI

CAL

MOU

NTIN

G HE

IGHT

S

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

No

.D

ate

Revis

ion

Page 4: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

a

J

GEN. DEMOLITION NOTESTHE OWNER RESERVES THE RIGHT TO SALVAGE ANY MATERIALS.

REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

1.

2.

3. FOR EXISTING ELECTRICAL/MECHANICAL DEMO NOTES/INFORMATION, REF. MEP DRAWINGS.

DEMOLITION KEY NOTESMARK DESCRIPTION

1REMOVE EXISTING WOOD FLOOR & SLEEPERS DOWN TO CONCRETE FLOOR THROUGHOUT THE SPACE

DEMOLITION LEGEND

EXISTING ITEMS TO BE REMOVED

EXISTING ITEMS TO REMAIN

2 PREPARE FLOOR TO RECEIVE CARPET TILES.

3 PREPARE CONCRETE FLOOR FOR NEW EPOXY RESIN FLOOR

4REPAIR AND PATCH EXISTING WALLS. PREP WALLS/SURFACES FOR NEW PAINT.

5 REMOVE AND DISPOSE OF EXISTING ACOUSTIC CEILING SYSTEM.

6REMOVE EXISTING DOOR, FRAME AND RAISED THRESHOLD. PREPARE OPENING FOR NEW FRAME

7 EXISTING PLASTER CEILING TO REMAIN.

8REPAIR/PATCH WALL, WINDOW SILLS/JAMBS AS REQUIRED. PREP FOR NEW PAINT.

13'-8

3/8

"4'

-9 5

/8"

15'-1 3/8"

1

2

2

2

4

5

6

7

8

14'-9 3/4"

7

7

4

4

4

4

1

1

1

6

4

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

3 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A101

K19503

10/1/2019

DEM

OLIT

ION

PLAN

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

1/4" = 1'-0"C3 EXISTING STORAGE RM DEMOLITION PLANN

No

.D

ate

Revis

ion

Page 5: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

FIN

ISH

FA

CE

4'-9

"

OFFICE205

STORAGE204

INTERVIEWROOM

203

C6

C3

C3

C3

D3

C3

C3

C3

C3

C3

204

205

202

201

6" 14'-7 3/8" 7'-11 7/8" 6'-10 7/8" ± 11'-6 5/8" 6" VERIFY IN FIELD

13'-8

3/8

"

5'-3 1/4" 3'-0 3/8" 3'-4 7/8" 3'-4 7/8"

1'-3

5/8

"13

'-8 3

/8"

5'-0

"4'

-4 1

/4"

9'-4

1/4

"

FIN

ISH

FA

CE

3'-6

"1'

-6"

A

B

C

DE

F

GH

I

A

1

5

6

7

8

10

11

5

6

5

6

CORRIDOR200

A102

A2

A1

WOMEN'SLOCKERROOM

201

INVESTIGATIONSOFFICE

202J

K

3'-0

5/8

"4'-6

"

13

L

ALIGN

20

20

3'-0"3'-0" CLEAR

A102

A4

FINISH FACE

4'-11 1/2"

D3

D3

ALIGN FACE OF NEW WALL FINISH W/ (E) WINDOW JAMB

206

22

DASHED LINES INDICATE WHEELCHAIR CLEARANCE AREAS

22

23

200

KEYED NOTESMARK DESCRIPTION

1

NOT USED

NOT USED

WALL MOUNTED TV, FURNISHED AND INSTALLED BY OWNER. G.C. TO REFER TO ELECTRICAL DRAWINGS FOR POWER AND COAXIAL OUTLETS.

2

3

4

5

6

7

8

NOT USED

DESK, FURNISHED AND INSTALLED BY OWNER

TASK CHAIR, FURNISHED AND INSTALLED BY OWNER

(5) 18"W X 24"D LOCKERS, FURNISHED AND INSTALLED BY G.C., SEE FINISH NOTES FOR MORE INFORMATION

4' LONG LOCKER BENCH, FURNISHED AND INSTALLED BY G.C.

922" SOLID SURFACE VANITY TOP, FURNISHED AND INSTALLED BY G.C., SEE DETAIL A2/A501.

10 TOILET PARTITION, FOR MFG AND FINISH SEE FINISH NOTES.

11 FLOOR DRAIN, SEE PLUMBING DRAWINGS FOR MORE INFORMATION

12

13

NOT USED

14

ADA COMPLIANT COMMERCIAL STACKED WASHER/DRYER, FURNISHED BY OWNER, INSTALLED BY G.C.; G.C. TO PROVIDE HOOKUPS, REF. PLUMBING DWG'S

15

KEYED NOTES CONT'DMARK DESCRIPTION

16

INTEGRAL ERF FLASH COVE BASE, 4" HIGH, SEE ROOM FINISH SCHEDULE & INTERIOR FINISH SCHEDULES

CERAMIC TILE WAINSCOT, SEE ROOM FINISH & INTERIOR FINISH SCHEDULES

17

18

19

20

21

22

23

24

25

26

27

28

SCHLUTER SCHIENE TERMINATION BAR, BRUSHED STAINLESS STEEL, TYPICAL

SCHLUTER RONDEC OUTSIDE CORNER, BRUSHED STAINLESS STEEL, TYPICAL

PAINT, SEE ROOM FINISH & INTERIOR FINISH SCHEDULES

TILE REDI SHOWER NICHE, #RN1614S-BI, MFG BY TILE-REDI, TRIM OUTSIDE CORNERS OF NICHE W/ SCHLUTER DIADEC

CORNER GUARDS, SEE FINISH SCHEDULE FOR MORE INFORMATION.

SCHLUTER DILEX-EHK INSIDE CORNER, BRUSHED STAINLESS STEEL, TYPICAL

WHERE RAISED THRESHOLD IS REMOVED, PATCH AND REPAIR CONCRETE TO PROVIDE SMOOTH SURFACE.

36"X36" SHOWER COMPARTMENT AND ACCESSIBLE APPROACH PER ANSI/CC A117.1-2009, FIGURE 1004.11.3.1.3.3 TRANSFER-TYPE SHOWER COMPARTMENT IN TYPE B UNITS

ACCESSORIES SCHEDULEMARK DESCRIPTION

TOILET TISSUE DISPENSER, BOBRICK B-76867

(1) 36" GRAB BAR, BOBRICK B-6806X36(1) 42" GRAB BAR, BOBRICK B-6806X42(1) 18" GRAB BAR, BOBRICK B-6806X18

A

B

PROVIDED/INSTALLED

PAPER TOWEL DISPENSER, SURFACE MOUNTEDC

SOAP DISPENSER, SURFACE MOUNTEDD

18"W X 36"H MIRROR, BOBRICK B-165X1836E

DOUBLE ROBE HOOK, BOBRICK B-6727F

SHOWER CURTAIN ROD, BOBRICK F.V. LENGTHG

SHOWER CURTAIN, BOBRICK B-204-2 W/ HEAVY DUTY HOOKS, BOBRICK B-204-1

H

SHOWER BASIN, SEE PLUMBING DWGSI

J

K

C.C.

C.C.

C.C.

C.C.

C.C.

C.C.

C.C.

C.C.

C.C.

LEGEND:

O.O. - OWNER SUPPLIED, OWNER INSTALLED

O.C. - OWNER SUPPLIED, CONTRACTOR INSTALLEDC.C. - CONTRACTOR SUPPLIED, CONTRACTOR INSTALLED

NOTES:1. ALL TOILET ROOM ACCESSORIES TO BE ADA AND ANSI 117.1-2003 COMPLIANT.

2. C.C. TO INSTALL PAPER TOWEL DISPENSERS AND SOAP DISPENSERS AT ALLNEW SINKS THROUGHOUT PROJECT, VERIFY LOCATIONS W/ OWNER.

3. G.C. TO INSTALL ROBE HOOKS ON BACK OF ALL TOILET STALL DOORS & BACK OF DOORS AT SINGLE PERSON TOILETS @ +66" A.F.F. UNLESS OTHERWISE INDICATED.

4. PROVIDE BLOCKING AT ALL TOILET PARTITIONS, URINAL SCREENS, GRAB BARS AND ACCESSORIES WHICH ARE WALL MOUNTED.

(1) 16"X31" TWO-WALL GRAB BAR, BOBRICK B-6861(1) 24" GRAB BAR, VERTICAL, BOBRICK B-6806X24

ADA SHOWER SEAT, BOBRICK B-5181

C.C.

C.C.

L SANITARY NAPKIN DISPOSAL, BOBRICK B-254 C.C.

GENERAL NOTESGENERAL NOTES_1W X 2H

GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS & TESTING REQUIRED FOR COMPLETE RELATED WORK. THE GENERAL CONTRACTOR SHALL ALSO BE IN CHARGE OF THE OPERATION FROM THE TIME OF COMMENCEMENT UNTIL THE COMPLETION OF WORK AND TO WHOM ALL ORDERS AND DIRECTIONS SHALL BE GIVEN.

ALL TRADES SHALL BE RESPONSIBLE TO READ ALL DRAWINGS, DETAILS, & PLANS ASSOCIATED WITH ALL PACKAGES INCLUDING ARCHITECTURAL & MEP ASSOCIATED WITH THIS PROJECT TO ENSURE PROPER COORDINATION. IF ANY CONFLICTS EXIST, THAT TRADE SHALL NOTIFY THE CONTRACTOR OF THE SAME PRIOR TO CONSTRUCTION WHO SHALL IN TURN NOTIFY THE G.C.

CONTRACTOR SHALL DIRECT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION, AND CONTRACTOR SHALL BE RESPONSIBLE FOR ANY WORK WHICH PROCEEDS WITHOUT DUE COURSE AND COORDINATION.

ALL MATERIALS SHOWN OR CALLED FOR ON THESE CONSTRUCTION DOCUMENTS TO BE NEW AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS.

ALL INTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.

NO BACK TO BACK JUNCTION BOXES SHALL BE PERMITTED IN SOUND PARTITIONS.

CONSTRUCTION TO BE IN STRICT ACCORDANCE WITH ALL APPLICABLE BUILDING CODES, LOCAL RULES AND REGULATIONS, AND ALL OTHER CODES, REGULATIONS AND GOVERNING AGENCIES HAVING JURISDICTION WITH ALL APPLICABLE AMENDMENTS UNLESS ALTERED OR CHANGED THROUGH VARIANCES OF OTHER LEGAL PROCEDURES.

COORDINATE ALL CONSTRUCTION PRIOR TO BEGINNING WORK AND SUBMIT PROPOSED WORK SCHEDULE TO THE OWNER & ARCHITECT FOR APPROVAL.

UNLESS OTHERWISE INDICATED, THE CONTRACT SCOPE INCLUDES ALL MATERIALS AND EQUIPMENT ON THE DRAWINGS.

ELECTRICAL CONTRACTOR TO PROVIDE ALL SMOKE DETECTORS, EXIT SIGNS, EMERGENCY LIGHT AND FIRE ALARM SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES.

NOT USED

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

FIELD VERIFY ALL EXISTING DIMENSIONS.

12.

14

15

1618

7

8

9

14

4"

D

E

F

1 1/2"

6'-8

"

16

17

18

16

17

18

9

DE

FGH

I

6'-8

"

19

16C

1314

15 14

J

K

18

21 10

A

B

L

MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IF SUBMITTED AS DESCRIBED IN THE PROJECT MANUAL.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

5 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A102

K19503

10/1/2019

FLOO

R PL

AN

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

N

1/2" = 1'-0"C3 SECOND FLOOR PLAN

3/8" = 1'-0"A1 WOMEN'S LOCKER ROOM - EAST3/8" = 1'-0"A2 WOMEN'S LOCKER ROOM - SOUTH

3/8" = 1'-0"A4 TOILET - SOUTH

No

.D

ate

Revis

ion

Page 6: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

JJOFFICE

205

STORAGE204

INTERVIEWROOM

203

GYP.9'-6"

ACT18'-6"

ACT18'-6"

ACT18'-6"

ACT18'-6"

WOMEN'SLOCKERROOM

201

INVESTIGATIONSOFFICE

202

CORRIDOR200

1

1

1

1

3

ACT19'-6"

2

GYP.7'-6"

ALIGN VERTICAL FACE OF SOFFIT WITH NEW FURRING

NOTE: SOME SYMBOLS MAY NOT BE USED IN THIS DRAWING OR PROJECT.

SUSPENDED LAY-IN ACOUSTICAL PANEL CEILING AND TEE-GRID SUSPENSION SYSTEM2'X4' (2'x 2' SECOND LOOK)

5/8" GYPSUM BOARD BULKHEAD, CEILING OR SOFFIT. -SEE APPLICABLE DETAILS AND SECTIONS.

REFL. CLG. PLAN LEGENDRCP LEGEND_1W X 3H

SUSPENDED LAY-IN ACOUSTICAL PANEL CEILING AND TEE-GRID SUSPENSION SYSTEM (2'X2').

2'X4' LAY-IN FLUORESCENT LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

2'X2' LAY-IN FLUORESCENT LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

RECESSED CAN LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

RECESSED CAN DIRECTIONAL LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE AND SIZE.

FLUORESCENT STRIP LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE AND SIZE.

EMERGENCY WALL MOUNTED LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

EMERGENCY EXIT LIGHT FIXTURE (CEILING MOUNTED). -SEE ELECTRICAL DRAWINGS FOR TYPE.

EMERGENCY EXIT LIGHT FIXTURE (WALL MOUNTED). -SEE ELECTRICAL DRAWINGS FOR TYPE.

CEILING MOUNTED RETURN AIR GRILLE. -SEE MECHANICAL DRAWINGS FOR TYPE.

CEILING MOUNTED SUPPLY DIFFUSER. -SEE MECHANICAL DRAWINGS FOR TYPE.

EXHAUST DUCT. -SEE MECHANICAL DRAWINGS FOR TYPE.

REFLECTED CEILING GENERAL NOTES

2.REFERENCE ELECTRICAL DRAWINGS FOR BALANCE OF LIGHTING INFORMATION. NOTE: ALL FIXTURES LOCATED IN LAY-IN ACOUSTICAL PANELS SHALL BE CENTERED IN CEILING PANELS UNLESS NOTED OTHERWISE.

3.REFERENCE MECHANICAL DRAWINGS FOR BALANCE OF MECHANICAL INFORMATION (I.E. SUPPLY DIFFUSERS, RETURN AIR GRILLES, ETC.).

1. SHOULD ANY CONFLICT ARISE BETWEEN MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS, REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO INSTALLATION.

2'X4' LAY-IN FLUORESCENT EMERGENCY LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

2'X2' LAY-IN FLUORESCENT EMERGENCY LIGHT FIXTURE. -SEE ELECTRICAL DRAWINGS FOR TYPE.

REFLECTED CLG KEYED NOTESMARK DESCRIPTION

1

2

3

4

5

6

7

8

9

10

SUSPEND AND SECURE ACOUSTIC CEILING SYSTEM FROM EXISTING CEILING.

12X18 CEILING ACCESS PANEL, SEE MECHANICAL DRAWINGS.

EXISTING HVAC DUCTS TO REMAIN, 10'-0" ABOVE FINISH FLOOR.

12 GA. HANGER WIRE.

CONTINUOUS CORNERSTRUT TO MAINTAIN RUNNER SPACING.

LAY-IN ACOUSTICAL PANEL CEILING.

15/16" EXPOSED TEE-GRID CEILING SUSPENSION SYSTEM

HEMMED WALL ANGLE TRIM.

FACE OF WALL.

8" (MAX.)

3" = 1'-0"

LAY-IN ACOUSTICAL PANEL CEILING DETAIL (TEGULAR)

PAINT EXPOSED TEGULAR END TO MATCH PANEL COLOR WHERE TEGULAR PANELS ARE CUT.

12 GA. HANGER WIRE.

5/8" GYPSUM BOARD CEILING.

SUSPENDED GYPSUM BOARD CEILING GRID SYSTEM.

METAL STUD PARTITION. -REFERENCE PARTITON TYPES

DETAILS.

3" = 1'-0"

SUSPENDED GYP. BD. CEILING DETAIL @ GYP. BD. PARTITION

-SEE REFLECTED CLG. PLAN FOR EL.

8" (MAX.)

CHANNEL MOLDING

GYPSUM BOARD.

PROVIDE REINFORCED JOINT TAPE @ WALL /CEILING INTERSECTION.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

5 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A103

K19503

10/1/2019

REFL

ECTE

D CE

ILING

PLA

N

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

1/4" = 1'-0"C3 SECOND FLOOR REFLECTED CEILING PLANN

A5A4

No

.D

ate

Revis

ion

Page 7: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

1

4

5

11

1

1

1 1

1 1

2

3

3

3

33

4

4

5

NOTE:ALL EXISTING ROOFTOP ELEMENTS ARE LOCATED IN APPROXMIATE POSITIONS. VERIFY POSITIONS IN FIELD.

6

7

8

9

ROOF PLAN KEYED NOTESMARK DESCRIPTION

1 EXISTING ROOFTOP UNITS

2

3

4

5

6

7

8

9

10

11

12

13

EXISTING RANGE HOOD EXHAUST FANS

EXISTING SKYLIGHTS

EXISTING CONDUITS

EXISTING EXHAUST FANS

NEW DRYER VENT, PROVIDE FLASHING AND SEALANT AROUND PENETRATION. SEE MEP ROOF PLAN.

NEW PLUMBING VENT, PROVIDE FLASHING AND SEALANT AROUND PENETRATION. SEE MEP ROOF PLAN.

NEW EXHAUST DUCT, PROVIDE FLASHING AND SEALANT AROUND PENETRATION. SEE MEP ROOF PLAN.

NEW ROOFTOP UNIT, SEE MECHANICAL DRAWINGS

1 1/4" GALV. ROOFINGNAILS AT 12" O.C. (MAX.).

PREFINISHED ALUMINUM COUNTERFLASHINGW/ 3" H. (MIN.) FACE.

FLASHING PER ROOFING MANUFACTURER'S RECOMMENDED PROCEDURES.

WELDED SPLICE.

EXISTING ROOFING.

P.T. WOOD NAILER

GASKETED FASTENER @ 12" O.C. (MAX.).

PREFABRICATED INSUL. METAL CURB. -SEE MECH. DWG'S.

R.T.U. -SEEMECH. DWG'S.

ROOFING MFG. FASTENERS @ 12" O.C. W/ SEALANT ALL AROUND.

FRTW NAILERSAS REQ'D.

EXISTING INSULATION.

EXISTING ROOF STRUCTURE.

8" (

MIN

.) T

O 2

4 (M

AX

.) N

.T.S

. AT

SLO

PE

D R

OO

FS

.

8" (

MIN

.) T

O 1

2 (M

AX

.) N

.T.S

. AT

FLA

T R

OO

F L

OC

AT

ION

S

N.T.S.

ROOF FLASHING DETAIL

NOTE: ON SLOPED ROOFS, PROVIDE PREFABRICATED METAL INSULATED TAPERED CURBS TO PROVIDE A LEVEL TOP FOR MECH. ROOF TOP EQUIP.

@ PREFAB. ROOF CURB

CONT. SEALANT AROUND CURB PERIMETER.

FASTENERS AND 2" SEAM PLATES AT 12" O.C.

RO

UN

D P

EN

ET

RA

TIO

N

CONTINUOUS BEAD OFSEALANT BY ROOFING MFG.

STAINLESS STEEL CLAMPING RING.

APPLY SEALANT BETWEEN PENETRATION AND PRE-MOLDED PIPE FLASHING PRIOR TO INSTALLATION OF CLAMPING RING.

NOTES:1.

DO NOT USE WHEN SERVICE LINE TEMP EXCEEDS 180°F.2.

THIS DETAIL APPLIES FOR LARGE PIPE PENETRATIONS BETWEEN 4" TO 8" DIAMETER.3.

CONTINUOUSBEAD OF HIGHGRADE SEALANT.

METAL HOOD.

SPLICE ALL AROUND.

PRE-MOLDED PIPE FLASHING. EXISTING ROOF

MEMBRANE.

EXISTING INSULATION.

EXISTING ROOF STRUCTURE.

N.T.S.

PIPE THRU ROOF PEN. DETAIL

ALL ASPECTS OF ROOFING WORK SHALL MEET MANUFACTURER'S REQUIREMENTS TO MAINTAIN EXISTING ROOFING AND INSULATION WARRANTIES. MODIFY DETAILS AS BELOW TO MEET MANUFACTURER'S REQUIREMENTS FOR EACH SPECIFIC SITUATION.

NOTE:THE EXISTING ROOF SYSTEM INCLUDES A DERBIGUM ROOF OVER SIPLAST INSULATION. IT WAS INSTALLED IN 2012 AND IS UNDER A 10-YEAR INSULATION WARRANTY AND 20- YEAR WARRANTY ROOF MEMBRANE WARRANTY. CONTRACTOR SHALL ONLY ACCEPT ROOFING CONTRACTOR’S TO PERFORM WORK WITHIN THIS CONTRACT WHO ARE CERTIFIED TO PROVIDE (FURNISH AND INSTALL) “DERBIGUM AND SIPLAST” ROOFING MATERIALS. THE ROOFING CONTRACTOR SHALL PROVIDE THIS CERTIFICATION TO THE CONTRACTOR FOR REVIEW AND APPROVAL TO THE ARCHITECT AND OWNER FOR APPROVAL. ALL PENETRATIONS, MODIFICATIONS, AND FLASHINGS SHALL BE COMPLETED ACCORDING TO MANUFACTURER’S PUBLISHED DETAILS AND RECOMMENDATIONS IN A MANNER THAT WILL RESULT IN NO REDUCTION IN WARRANTY COVERAGE FOR THIS ROOFING SYSTEM.

DERBIGUM SPECIFICATION: 1N2G-FRUDERBIGUM FLASHING MATERIAL: DERBIGUM GP DERBIGUM GP FR

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

6 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A104

K19503

10/1/2019

ROOF

PLA

N

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

1/8" = 1'-0"B2 ROOF PLANN

A5 A6

No

.D

ate

Revis

ion

Page 8: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

C NON-RATED PARTITION

N/A

N/A

MARKSTRUCT

SIZEPARTTHICK S.T.C. REMARKS

BASIS OF DESIGN:

FIRE RATING:

SCALE: 3" = 1'-0"

S.A.B.SIZE

REMARKS:

D NON-RATED PARTITION

N/A

N/A

MARKSTRUCT

SIZEPARTTHICK S.T.C. REMARKS

BASIS OF DESIGN:

FIRE RATING:

SCALE: 3" = 1'-0"

S.A.B.SIZE

REMARKS:

C3 3 5/8" 4 7/8" - A-

A. STUD SPACING 16" O.C. MAX

LINE OF STRUCTURE

LINE OF STRUCTURE

C6 6" 7 1/4" - A-

ACOUSTIC SEALANT EACH SIDE

MTL RUNNER

(1) LAYER 5/8" GYPSUM BOARD EACH SIDE

PARTITION WIDTHPER SCHEDULE BELOW

EXTEND SOUND ATTENUATED BATT (S.A.B.) TO DECK, WHERE OCCURS PER SCHEDULE BELOW

LINE OF CEILING. PER REFLECTED CEILING PLAN

ACOUSTIC SEALANT EACH SIDE

REFER TO PARTITION HEAD DETAILS FOR APPLICABLE CONDITIONS

METAL STUDS PER SCHEDULE BELOW

09.21.16.01_C NR PARTITION

D3 3 5/8" 4 1/4" - A-

LINE OF STRUCTURE

LINE OF STRUCTURE

FLOORING PER FINISH FLOOR PLAN MTL RUNNER

(1) LAYER 5/8" GYPSUM

LINE OF CEILING. PER REFLECTED CEILING PLAN

REFER TO PARTITION HEAD DETAILS FOR APPLICABLE CONDITIONS

METAL STUDS PER SCHEDULE BELOW

BASE PER FINISH FLOOR PLAN

PARTITION WIDTHPER SCHEDULE BELOW

A. STUD SPACING 16" O.C. MAX

09.21.16.01_D NR PARTITION

PARTITION KEY LEGEND

F3A

PARTITION TYPE

ALTERNATE CONFIGURATION DESIGNATOR

STUD/STRUCTURE WIDTH

GENERAL PART. TYPE NOTES1. BASE OF WALL DETAILS ARE INTENDED AS GENERAL REFERENCE ONLY. 2. LISTED UL (UNDERWRITERS LABORATORIES) ASSEMBLIES ARE BASIS OF DESIGN

ONLY AND NOT ALL REQUIREMENTS ARE SHOWN. REFERENCE UL FOR ADDITIONAL INFORMATION.

3. INSTALL DEFLECTION TRACK AT TOP OF ALL FULL HEIGHT WALLS.4. INSTALL MOISTURE RESISTANT GYPSUM BOARD AT ALL WALLS ADJACENT TO WATER.5. PROVIDE STENCILED OR STICKER RATING IDENTIFICATION OF EACH RATED

PARTITION AT 10'-0" ON CENTER (MINIMUM ONCE PER ROOM) ABOVE THE CEILING. LETTERING TO BE MINIMUM 1/2" IN HEIGHT AND STATE "FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS"

6. SEE DETAILS THIS SHEET FOR RATED WALL INTERSECTION PRIORITY INSTALLATION.7. SEE DETAILS THIS SHEET FOR DETAILS OF WALL CONSTRUCTION AT BOXES

RECESSED IN RATED WALLS.8. PARTITIONS THAT INCLUDE SOUND INSULATION & SEALANT ARE TO BE CONSIDERED

ACOUSTIC PARTITIONS AND USE THE ACOUSTIC TERMINATION DETAILS.9. RATED DESIGN ASSEMBLIES LISTED ARE BASIS OF DESIGN ONLY. ALTERNATES WILL

BE ACCEPTED BASED UPON MATERIALS USED SO LONG THAT THE INDICATED RATING IS MAINTAINED. ALTERNATE ASSEMBLIES SHOULD BE SUBMITTED TO ARCHITECT FOR APPROVAL.

10. INSTALL CONTROL JOINTS IN METAL STUD WALLS PER DETAIL

1. FASTEN TRACKS TO EXISTING CEILING AT 24" O.C. UNLESS NOTED OTHERWISE2. DO NOT FASTEN GYP BD TO DEFLECTION TRACK. FASTEN TO EACH VERTICAL

STUD 2" MAXIMUM BELOW THE BOTTOM LEG OF THE DEFLECTION TRACK, UNLESS NOTED OTHERWISE.

GEN. HEAD OF WALL NOTES

09.22.16 TYP. JAMB DETAILS6" = 1'-0"

TYP. FRAMING JAMB DETAILS

TYP. 20 GA. STUD.

TYP. 20 GA. STUD.

6

DOUBLE KING STUD JAMB

3/8" = 1'-0"

TYPICAL INTERIOR PARTITION FRAMING ELEVATIONS09.22.16 TYP INT PARTITION FRAMING ELEV

DOOROPENING

4'-0" MAX.

DOUBLE STUDS

GENERAL NOTES:

1. ALL STUDS ARE SPACED 16" O.C. MAX.2. ALL STUDS SHOULD BE "C" STUDS WITH 1/4" FLANGE MINIMUM.3. METAL STUD MANUFACTURER TO PROVIDE BRIDGING AS REQUIRED AT ALL INTERIOR PARTITIONS.4. IN NO INSTANCE SHALL DOUBLE STUDS BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEMS.5. IN PROJECTS WITHIN SEISMIC ZONES, MINIMUM STUD GAUGE IS 20 GA. DETAILS TO BE MODIFIED ACCORDINGLY.

UNDERSIDE OF SLAB, FLOOR OR ROOF DECK.

CEILING LINE

FLOOR LINE

TYPICAL BOTTOM TRACK

66

2A

6" = 1'-0"

TYP. FRAMING HD DTL

TYP. 20 GA. STUD.

TYP. 20 GA. STUD TRACK.

2ADOUBLE HEADER

SEE PARTITION TYPES

WIDTH VARIES

TYP. 20 GA. STUD

#10 S.M.S @ EA. STUD, EA. SIDE.

FRT WD. BLOCKING @ H.M. FRAME & LOUVER LOCATIONS

(2) ROWS OF #10 S.M.S. @ 4" O.C.

PL. LAM.REMOVABLE PANEL.

PLAS. LAM.APRON

4"H SDS BACKSPLASHPROVIDE END SPLASH AT TERMINAL WALLLOCATIONS

SINK. -SEE PLUMBING DRAWINGS

1/2" SOLID SURFACE (SDS) TOP ON 3/4" EXT PLYWD.

U. O. N.

2'-0"

1"

6 1

/64

"

1 3

1/6

4"

2"

2'-10

"4

"

1 1/2" = 1'-0"

SINK ENCLOSURE w/ SDS

SEALANT

SEE FIN. SCHED. FOR

BASE & FLOOR

3/4" x 3/4" CLEAT

NOTE: COORDINATE SINK AND PLUMBING PIPE W/ REMOVABLE PANEL

EASED EDGESTOP AND BOTTOM

12.35.53.19.14 SINK ENCLOSURE_SDS

10"

7"

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

7 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A501

K19503

10/1/2019

PART

ITIO

N TY

PES

& M

ISC.

DET

AILS

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

B4

C1

B5

A3

No

.D

ate

Revis

ion

Page 9: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

2"

SCHED

SEE DOOR2"

2"S

EE

DO

OR

SC

HE

D

TYPICAL HOLLOW METAL FRAME DOOR HEAD DETAIL 3" = 1'-0" 08.11.13.01_LG HM DOOR HEAD DETAIL

OP

NE

NIN

G H

EIG

HT

PE

R S

CH

ED

ULE

WALL PARTITION -REFERENCE PLAN ANDPARTITION TYPES.

HOLLOW METAL DOOR FRAME.

DOOR. -SEE DOOR SCHEDULE.

PLAN & PART. TYPES

PART. WIDTH. -REF

1 7/8" VARIES 1 7/8"

PARTITION WIDTH + 7/8"

2"

1/2

"

7/16" 7/16"STEEL STUD ANCHOR BY DOOR FRAME MFG.

REFERENCE TYPICAL FRAMING HEAD DETAILS 1, 2A OR 2B FOR FRAMING @ DOOR HEAD.

2"

TYPICAL HOLLOW METAL FRAME DOOR JAMB DETAIL 3" = 1'-0" 08.11.13.01_LG HM DOOR JAMB DETAIL

OPENING WIDTHPER SCHEDULE

WALL PARTITION -REFERENCE PLAN AND PARTITION TYPES.

20 GA. DBL. METAL JAMB STUDS.

HOLLOW METAL DOOR FRAME.

DOOR. -SEE DOOR SCHEDULE.

PA

RT

ITIO

N W

IDT

H +

7/8

"

2"

PLA

N &

PA

RT

. T

YP

ES

PA

RT

. W

IDT

H.

-R

EF

.

1 7

/8"

VA

RIE

S1

7/8

"

7/1

6"

7/1

6"

STEEL STUD ANCHOR BY DOOR FRAME MFG.

2" 1/2"

FFLUSH S.C. WD. OR H.M. DOOR.

-SEE DOOR SCHEDULE.

1/4" = 1'-0"

DOOR TYPE ELEVATIONS

FINISH SCHEDULE

ACT1

ACOUSTICAL CEILING TILES - FIELDMFGR: ARMSTRONGPATTERN: OPTIMA TEGULARMODEL: 3354 SIZE: 24X24, 15/16" GRID COLOR: WHITE

ACOUSTICAL CEILING

CT1

LOCKER ROOM WALL TILE - FIELDMFGR: EMSER TILEPRODUCT: CHOICECOLOR: FAWN GLOSSSIZE: 12X24 INSTALL METHOD: VERTICAL STACK BOND PATTERN

GROUT: TEC POWER GROUT, "908 DOVE GRAY"

CERAMIC TILE

CT2

LOCKER ROOM WALL TILE - ACCENT BANDMFGR: STONEPEAK CERAMICSPRODUCT: MAIOLICACOLOR: ROSSOSIZE: 4X12 INSTALL METHOD: HORIZONTAL STACK BOND PATTERN OFFSET

FROM FIELD TILE AS SHOWN ON DRAWINGS

GROUT: TEC POWER GROUT, "908 DOVE GRAY"

EPOXY RESIN FLOORING

LOCKER ROOM FLOORINGMFGR: STONHARDPRODUCT: STONTEC TRF THICKNESS: 3/16"FINISH: ALIPHATIC POLYASPARTIC CLEAR GLOSS TOP COATCOLOR: TO BE SELECTED FROM MANUFACTURER'S STANDARD COLORSINSTALL METHOD: COLORED DECORATIVE FLAKE BROADCAST AGGREGATE AT SPREAD RATES RECOMMENDED BY MFR.

ERF

PAINT

PT1

INTERIOR - WALLS - FIELD COLORMFGR: SHERWIN WILLIAMSSERIES: PROMAR 200, ZERO VOCFINISH: EG-SHELCOLOR: SW 7631 "CITY LOFT"

PT3

INTERIOR - DOOR FRAMESMFGR: SHERWIN WILLIAMSSERIES: PROMAR 200, ZERO VOCFINISH: SEMI-GLOSSCOLOR: MATCH ADJACENT WALL COLOR

PT4

INTERIOR - GYPSUM BOARD CEILINGSMFGR: SHERWIN WILLIAMSSERIES: PRO INDUSTRIAL WATERBORNE ACRYLIC DRYFALL SYSTEMCOLOR: SW 7005 "PURE WHITE"

SOLID SURFACE MATERIALS

SC1

LOCKER ROOM VANITY COUNTERTOP & BACKSPLASHMFGR: WILSONARTCOLOR: 9203CE "DUSK ICE"GAUGE: 1/2"INTEGRAL BOWL TO BE DECIDED, COLOR: WHITE

WALL PROTECTION

WP1

CORNER GUARDSMFGR: INPRO CORPSTYLE: 11248 TEXTURED TAPE ON, 1-1/2" WING, 4'-0" HEIGHTCOLOR: 0113 TAUPE

WINDOW COVERING

WC1

WINDOWSMFGR: MECHO SHADE SYSTEMSMANUAL ROLLER SHADE - FULL WIDTH SHADE CLOTHMODEL: EUROVEIL SERIES 5300 (ROOM 202)

EQUINOX SERIES 0100 (ROOM 205)

WOOD STAINED

WS1 PREFINISHED WOOD DOORSCOLOR: EGGERS 07 DARK OAK

CARPET TILE

CPT1

MODULAR CARPET TILEMFGR: TANDUS CENTIVAPATTERN: MAELSTROM #04849 COLOR: NEW AGE #33207SIZE: 24X24 INSTALL METHOD: VERTICAL ASHLAR

PLASTIC LAMINATE

PL1

PLASTIC LAMINATE - VANITY ANGLED PANEL & APRONMFGR: WILSONARTSTYLE: LINEARITY FINISHCOLOR: 7942-18 "COCOBALA"

NOTE : VERTICAL GRAIN DIRECTION, INSTALL W/ MATCHING 1MM EDGEBANDING

PT2

INTERIOR - WALL - ACCENT COLORMFGR: SHERWIN WILLIAMSSERIES: PROMAR 200, ZERO VOCFINISH: EG-SHELCOLOR: SW 7586 "STOLEN KISS"

RESILIENT BASE

B14" COVE BASEMFGR: JOHNSONITE/TARKETTCOLOR: 20 CHARCOAL

ROOM FINISH LEGENDRM FINISH LEGEND_1W X 1H

PNT - PAINTB1 - RESILIENT BASEACT - ACOUSTICAL CEILINGSCT1 - CERAMIC TILEERF - EPOXY RESIN FLOORINGGYP - GYPSUM BOARD CEILINGCPT - CARPET(E) WD FLR - EXISTING WOOD FLOOR

MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IF SUBMITTED AS DESCRIBED IN THE PROJECT MANUAL.

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

imag

es-

stl.c

om

SC

ALE

: 1/1

6"

= 1

'-0"

SC

ALE

: 1/8

" =

1'-0"

SC

ALE

: 1/4

" =

1'-0"

SC

ALE

: 3/8

" =

1'-0"

SC

ALE

: 1/2

" =

1'-0"

SC

ALE

: 3/4

" =

1'-0"

SC

ALE

: 1"

= 1

'-0"

SC

ALE

: 1 1

/2"

= 1

'-0"

SC

ALE

: 3"

= 1

'-0"

C

Lene

xa, K

ansa

s 6

6215

14205 W

. 95th

Str

eet

p:

[9

13

] 3

78

.95

33

KS

Arc

hitectu

ral C

orp

ora

tion A

rchim

ages, In

c. # A

-669

10

/2/2

01

9 3

:33:1

8 P

M

C:\U

se

rs\a

flory

\acad

\K19

503

- K

CK

FD

HQ

Rem

od

el_

CE

NT

RA

L_

aflo

ry8F

8X

U.r

vt

A601

K19503

10/1/2019

DOOR

& F

INIS

H SC

HEDU

LES

INV

ES

TIG

AT

ION

S A

ND

WO

ME

N'S

LO

CK

ER

RO

OM

RE

MO

DE

L

Pro

pose

d:

815

N. 6

TH

ST

RE

ET

, KA

NS

AS

CIT

Y, K

AN

SA

S

U.G

. PR

OJE

CT

NU

MB

ER

BB

2984

4

KA

NS

AS

CIT

Y K

AN

SA

S F

IRE

DE

PA

RT

ME

NT

HE

AD

QU

AT

ER

S

F01F01 HOLLOW METAL FRAME

FINISH FLOOR

B1

A1

D1

MARK PAIR WIDTH HEIGHT THICK

FRAME PROPERTIES DOOR PROPERTIES

FIRE RATINGHARDWARE

GROUP COMMENTSFRAME TYPEFRAME

MATERIAL FRAME FINISHSIDELIGHTGLAZING HEAD JAMB TYPE

DOORMATERIAL DOOR FINISH

DOORGLAZING

200 3'-0" 7'-0" 1 3/4" F02 HM PAINT - B1/A601 A1/A601 -NONE- - - - 0 -

201 3'-0" 7'-0" 1 3/4" F01 HM PAINT - B1/A601 A1/A601 -F- SC WD STAIN - 0 3 UNDERCUT DOOR BOTTOM 1", SEE SHEET M101

202 3'-0" 7'-0" 1 3/4" F01 HM PAINT - B1/A601 A1/A601 -F- SC WD STAIN - 0 2 UNDERCUT DOOR BOTTOM 1", SEE SHEET M101

204 3'-0" 7'-0" 1 3/4" F01 HM PAINT - B1/A601 A1/A601 -F- SC WD STAIN - 20 4 UNDERCUT DOOR BOTTOM 1", SEE SHEET M101

205 3'-0" 7'-0" 1 3/4" F01 HM PAINT - B1/A601 A1/A601 -F- SC WD STAIN - 0 1

206 3'-0" 7'-0" 1 3/4" F01 HM PAINT - B1/A601 A1/A601 -F- SC WD STAIN - 0 5 UNDERCUT DOOR BOTTOM 1", SEE SHEET M101

1/4" = 1'-0"

FRAME TYPE ELEVATIONS C1

DOOR SCHEDULE

ROOM FINISH SCHEDULEROOM

NUMBER ROOM NAMEFLOORFINISH

NORTH EAST SOUTH WEST

CEILINGFINISH

CEILINGHEIGHT REMARKS

WALLFINISH

BASEFINISH

WALLFINISH

BASEFINISH

WALLFINISH

BASEFINISH

WALLFINISH

BASEFINISH

200 CORRIDOR CPT PNT2 B1 PNT1 B1 PNT1 B1 PNT1 B1 ACT 9'-6"

201 WOMEN'S LOCKER ROOM ERF CT1/PNT1 ERF CT1/PNT1 ERF CT1/PNT1 ERF CT1/PNT1 ERF GYP 9'-6" T.O. CERAMIC TILE 6'-8" A.F.F.

202 INVESTIGATIONS OFFICE CPT PNT1 B1 PNT1 B1 PNT1 B1 PNT1 B1 ACT 9'-6"

203 INTERVIEW ROOM CPT PNT1 B1 PNT1 B1 PNT1 B1 PNT1 B1 ACT 9'-6"

204 STORAGE CPT PNT1 B1 PNT1 B1 PNT1 B1 PNT1 B1 ACT 9'-6"

205 OFFICE CPT PNT1 B1 PNT1 B1 PNT1 B1 PNT1 B1 ACT 9'-6"

GENERAL & ARCHITECTURAL REQUIREMENTS:

SELECTIVE DEMOLITION:1. EXCEPT WHERE NOTED OTHERWISE ON THE DRAWINGS, DEMOLISHED ITEMS ARE TO BE REMOVED FROM THE PREMISES AND

LEGALLY DISPOSED OF OFF SITE.2. MINIMIZE AND CONTAIN PRODUCTION OF DUST FROM DEMOLITION OPERATIONS. SEPARATE AREAS IN WHICH DEMOLITION IS

BEING CONDUCTED FROM OTHER AREAS THAT ARE STILL OCCUPIED.3. PROTECT EXISTING WORK TO REMAIN.

ROOFING:1. PROVIDE NEW MATERIALS COMPATIBLE WITH EXISTING TO MAKE REPAIRS AND PROVIDE FLASHING AS NECESSARY FOR A

WATER TIGHT INSTALLATION.2. COORDINATE WITH OWNER TO ASSURE THAT ANY EXISTING ROOFING WARRANTIES REMAIN IN AFFECT.

DOOR FRAMES:1. MINIMUM 16 GAUGE ANSI/SDI A250.8. FACE OR FULL PROFILE WELDED AND GROUND SMOOTH. LEVEL THREE – EXTRA HEAVY

DUTY. PRIMED FOR ON-SITE PAINTING.

DOORS: 1. 1 ¾” SOLID CORE FLUSH WOOD DOORS. FIRE RATING AS INDICATED ON DRAWINGS. 2. PLAIN SLICED SELECT BIRCH BOOK MATCH VENEER. 3. FACTORY MACHINED AND FINISHED (STAINED WITH SATIN SHEEN TRANSPARENT FINISH).

GYPSUM BOARD ASSEMBLIES:1. NON-LOAD BEARING FRAMING: ASTM C645; GALVANIZED SHEET STEEL, SIZE & PROPERTIES TO COMPLY WITH ASTM C754, L/120

MAXIMUM DEFLECTION.2. CEILING CHANNELS AND HANGERS: TYPE AND SIZE AS INDICATED IN ASTM C754.3. GYPSUM WALLBOARD: 5/8” THICKNESS. AT FIRE RATED ASSEMBLIES – TYPE X BOARD, UL OR WH LISTED.4. SOUND BATTS: UNFACED GLASS FIBER ACOUSTICAL INSULATION COMPLYING WITH ASTM C 665, TYPE I. 5. WET AREAS: MOISTURE RESISTANT GYPSUM BOARD, ASTM C 473.6. BEHIND TILE: ANSI CEMENT-BASED BOARD, AGGREGATED PORTLAND CEMENT PANELS WITH GLASS FIBER MESH EMBEDDED

FRONT AND BACK, ANSI 118.9 OR ASTM C1325. PROVIDE ADDITIONAL FRAMING AND/OR BLOCKING BEHIND ALL JOINTS.

ACOUSTICAL CEILINGS:1. SUSPENSION SYSTEM: 15/16” DOUBLE WEB TEE SYSTEM, WHITE. COMPLY WITH SEISMIC REQUIREMENTS OF 2012

INTERNATIONAL BUILDING CODE.2. TILES: ARMSTRONG OPTIMA 24 X 24 TEGULAR

MODULAR CARPET TILE:1. SAND AND PREPARE EXISTING WOOD FLOOR AS NECESSARY TO INSTALL CARPET TILE.2. ALTERNATE BID TO DELETE CARPET TILE AND REFINISH WOOD FLOOR AS PER WOOD FLOOR SECTION BELOW IN ROOMS 202

AND 204.

RESILIENT BASE:1. 1/8-INCH GAUGE VINYL, 4-INCH COVE BASE, JOHNSONITE/TARKETT COLOR 20 CHARCOAL

INTERIOR PAINTING:1. PROVIDE PATCHING AND SANDING FOR EXTERIOR WALLS AS NECESSARY TO CREATE SMOOTH FINISH FOR PAINTING.2. GYPSUM BOARD: LATEX, 3-COAT SYSTEM, SATIN, LOW VOC, SHERWIN-WILLIAMS PROMAR 200 OR APPROVED EQUAL.

A. FIELD COLOR – SW 7631 CITY LOFTB. ACCENT COLOR – SW 7586 STOLEN KISS

3. DOOR FRAMES, WOOD TRIM, AND WINDOW SILLS: LATEX, 2-COAT SYSTEM (PLUS PRIMER WHERE NEEDED), SEMI-GLOSS SHERWIN-WILLIAMS PROMAR 200 OR APPROVED EQUAL. MATCH ADJACENT WALL COLOR.

4. WINDOWS: DO NOT PAINT EXISTING WINDOW FRAMES.

TOILET PARTITIONS:1. POWDER COATED STEEL, FLOOR-MOUNTED, HEADRAIL-BRACED2. SHEET STEEL FACES PRESSURE BONDED TO SOUND DEADENING CORE. MINIMUM 20-GAUGE PANEL AND PILASTER FACES,

MINIMUM 22-GAUGE DOOR FACES, 12-GAUGE REINFORCEMENT.3. PROVIDE REINFORCEMENT IN AREAS OF ATTACHED HARDWARE AND FOR ALL PARTITION MOUNTED ACCESSORIES.

WELDED METAL LOCKERS:1. WELDED FRAME, MINIMUM 16-GUAGE. RIVETING NOT PERMITTED2. 16-GUAGE INTERIOR SUBDIVISION AND SHELF3. 1-INCH COAT ROD4. HEAVY DUTY HOOKS5. NO EXPOSED FASTENERS ON END AND BACK PANELS6. SINGLE PIECE BI-PARTING VENTILATED LOUVER TOP AND BOTTOM OF DOORS WITH FULL LENGTH HINGE AND PADLOCK HASP.7. LOCKER TAG/NAME SLOT

LOCKER ROOM BENCH1. SOLID HDPE PLASTIC BENCH TOP 1 ½” X 9 ½” X 48”. 2. 6061 ALUMINUM BASES AND PEDESTALS, BLACK ANODIZED3. MANUFACTURER: ROYAL PLASTIC LOCKERS OR APPROVED EQUAL

COUNTERTOPS:1. SOLID SURFACE COUNTERTOP: WILSONART SOLID SURFACE DUSK ICE 9203CE.

APPLIANCES: 1. STACKING WASHER/DRYER FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR.

SCHEDULED DOOR HARDWAREA. PROVIDE DOOR HARDWARE FOR EACH DOOR AS SCHEDULED BELOW TO COMPLY WITH REQUIREMENTS.

1. DOOR HARDWARE SETS: PROVIDE QUANTITY, ITEM, SIZE, FINISH OR COLOR INDICATED, AND PRODUCTS EQUIVALENT IN FUNCTION AND COMPARABLE IN QUALITY TO NAMED PRODUCTS.

B. DESIGNATIONS: REQUIREMENTS FOR DESIGN, GRADE, FUNCTION, FINISH, SIZE, AND OTHER DISTINCTIVE QUALITIES OF EACH TYPE OF DOOR HARDWARE ARE INDICATED IN "DOOR HARDWARE SCHEDULE". PRODUCTS ARE IDENTIFIED BY USING DOOR HARDWARE DESIGNATIONS:

1. NAMED MANUFACTURERS' PRODUCTS: MANUFACTURER AND PRODUCT DESIGNATION ARE LISTED FOR EACH DOOR HARDWARE TYPE REQUIRED FOR THE PURPOSE OF ESTABLISHING MINIMUM REQUIREMENTS. MANUFACTURERS' NAMES ARE ABBREVIATED IN "DOOR HARDWARE SCHEDULE". 2. REFERENCES TO BHMA DESIGNATIONS: PROVIDE PRODUCTS COMPLYING WITH THESE DESIGNATIONS AND REQUIREMENTS FOR DESCRIPTION, QUALITY, AND FUNCTION.

HINGES A. HINGES: BHMA A156.1.

1. MANUFACTURERS: A. BOMMER INDUSTRIES, INC.B. IVESC. STANLEY

MECHANICAL LOCKS AND LATCHES A. LOCK FUNCTIONS: AS INDICATED IN DOOR HARDWARE SCHEDULE. B. LOCK BACKSET: 2-3/4 INCHES (70 MM), UNLESS OTHERWISE INDICATED. C. LOCK TRIM:

1. OPERATING DEVICE: LEVER WITH ESCUTCHEONS (ROSES). D. STRIKES: PROVIDE MANUFACTURER'S STANDARD STRIKE FOR EACH LOCK BOLT OR LATCHBOLT COMPLYING WITH REQUIREMENTS INDICATED FOR APPLICABLE LOCK OR LATCH AND WITH STRIKE BOX AND CURVED LIP EXTENDED TO PROTECT FRAME; FINISHED TO MATCH LOCK OR LATCH. E. MORTISE LOCKS: BHMA A156.13; SERIES 1000, GRADE 1.

1. MANUFACTURERS: A. FALCONB. SARGENTC. SCHLAGE

LOCK CYLINDERS A. LOCK CYLINDERS: STANDARD CORE TYPE, CONSTRUCTED FROM BRASS OR BRONZE, STAINLESS STEEL, OR NICKEL SILVER WITH SCHLAGE “C” KEYWAY.

1. MANUFACTURERS: A. FALCONB. SCHLAGE C. SARGENT

OPERATING TRIM A. OPERATING TRIM: BHMA A156.6; AS INDICATED.

1. MANUFACTURERS: A. BURNSB. IVESC. TRIMCO

SURFACE CLOSERS A. SURFACE CLOSERS: BHMA A156.4; RACK-AND-PINION HYDRAULIC TYPE WITH ADJUSTABLE SWEEP AND LATCH SPEEDS CONTROLLED BY KEY-OPERATED VALVES AND FORGED-STEEL MAIN ARM. COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR SIZE OF DOOR CLOSERS DEPENDING ON SIZE OF DOOR, EXPOSURE TO WEATHER, AND ANTICIPATED FREQUENCY OF USE. PROVIDE FACTORY-SIZED CLOSERS, ADJUSTABLE TO MEET FIELD CONDITIONS AND REQUIREMENTS FOR OPENING FORCE.

1. MANUFACTURERS: A. LCNB. FALCONC. SARGENT

2. ALL CLOSERS UL CERTIFIED TO BE IN COMPLIANCE WITH UBC 7.2 AND UL 10C. 3. SUPPLIER TO PROVIDE ANY BRACKETS OR PLATES REQUIRED FOR PROPER INSTALLATION OF DOOR CLOSERS. 4. PROVIDE CLOSERS AT ALL RATED DOORS.

THRESHOLDS & WEATHERSTRIPPING A. AS LISTED IN THE HARDWARE SETS AND FABRICATED TO OPENING SIZE INDICATED.

1. MANUFACTURERS: A. NATIONAL GUARD PRODUCTSB. REESEC. ZERO

METAL PROTECTIVE TRIM UNITSA. METAL PROTECTIVE TRIM UNITS: BHMA A156.6; FABRICATED FROM 0.050-INCH- (1.3-MM-) THICK STAINLESS STEEL; WITH MANUFACTURER'S STANDARD MACHINE OR SELF-TAPPING SCREW FASTENERS.

1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, AVAILABLE MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:

A. BURNSB. IVES C. TRIMCO

AUXILIARY DOOR HARDWARE A. AUXILIARY HARDWARE: BHMA A156.16.

1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, AVAILABLE MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:

A. BURNSB. IVESC. TRIMCO

DOOR HARDWARE SCHEDULE

HARDWARE GROUP NO.1FOR USE ON MARK/DOOR #(S):205, 206PROVIDE EACH SGL DOOR(S) WITH THE FOLLOWING:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HINGE 5BB1HW 4.5X4.5 652 IVE1 EA PRIVACY W/ L9440 06A 626 SCH

DEADBOLT1 EA SURFACE CLOSER 1450 RW/PA 689 LCN1 EA KICK PLATE 8400 10” X2” LDW B-CS 630 IVE1 EA WALL STOP WS406/407CCV 630 IVE1 EA GASKETING 188FSBK PSA BK ZER

HARDWARE GROUP NO.02FOR USE ON MARK/DOOR #(S):202PROVIDE EACH SGL DOOR(S) WITH THE FOLLOWING:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HINGE 5BB1HW 4.5X4.5 652 IVE1 EA PASSAGE SET L9010 06A 626 SCH1 EA KICK PLATE 8400 10” X2” LDW B-CS 630 IVE1 EA WALL STOP WS406/407CCV 630 IVE3 EA SILENCER SR64 GRY IVE

HARDWARE GROUP NO.03FOR USE ON MARK/DOOR #(S):201PROVIDE EACH SGL DOOR(S) WITH THE FOLLOWING:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HINGE 5BB1HW 4.5X4.5 652 IVE1 EA PUSH PLATE 8200 4X16 630 IVE1 EA PULL PLATE 8302 4X16 630 IVE1 EA SURFACE CLOSER 1450 RW/PA 689 LCN1 EA KICK PLATE 8400 10” X2” LDW B-CS 630 IVE1 EA WALL STOP WS406/407CCV 630 IVE3 EA SILENCER SR64 GRY IVE

HARDWARE GROUP NO.4FOR USE ON MARK/DOOR #(S):204PROVIDE EACH SGL DOOR(S) WITH THE FOLLOWING:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HINGE 5BB1HW 4.5X4.5 652 IVE1 EA PASSAGE SET L9010 06A 626 SCH1 EA KICK PLATE 8400 10” X2” LDW B-CS 630 IVE1 EA OH STOP 81S 630 GLY3 EA SILENCER SR64 GRY IVE

HARDWARE GROUP NO.5FOR USE ON MARK/DOOR #(S):203PROVIDE EACH SGL DOOR(S) WITH THE FOLLOWING:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HINGE 5BB1HW 4.5X4.5 652 IVE1 EA PASSAGE SET L9010 06A 626 SCH1 EA KICK PLATE 8400 10” X2” LDW B-CS 630 IVE1 EA OH STOP 81S 630 GLY3 EA SILENCER SR64 GRY IVE1 EA GASKETING 188FSBK PSA BK ZER

F02 WOOD CASED OPENING

(MATCH MOULDING ON ADJACENT WOOD DOOR FRAMES)

No

.D

ate

Revis

ion

Page 10: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

MECHANICAL SYMBOLS PIPING ABBREVIATIONS

GENERAL MECHANICAL NOTES (APPLICABLE TO ALL SHEETS)

HVAC EQUIPMENT AND DUCTWORKPIPING LINETYPESNOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE, FREE AREA DIMENSIONS.

PLUMBING EQUIPMENT

1. THE PLANS ARE TO A GREAT EXTENT SCHEMATIC IN NATURE. DRAWING SCALES SHOULD BE VERIFIED FROM DIMENSIONS ON ARCHITECTURAL PLANS. THE INFORMATION PRESENTED IS AS EXACT AS COULD BE SECURED. THE CONTRACTOR SHALL OBTAIN EXACT LOCATION, MEASUREMENTS, LEVELS, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT THE WORK TO THE ACTUAL CONDITIONS AT THE PROJECT SITE. ALL UNDERGROUND UTILITIES MUST BE VERIFIED AND LOCATED TO AVOID DAMAGE AND DISRUPTION OF SERVICES.

2. THE INTENT OF THE DRAWINGS ARE TO CONVEY THE WORK REQUIRED FOR THIS PROJECT NOT THE TRADE REQUIRED. THE CONTRACTOR IS TO REVIEW ALL DRAWINGS FOR THEIR WORK.ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ORDINANCES, AND ALL AUTHORITIES HAVING JURISDICTION.

3. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL ENGINEERING REQUIREMENTS, THE OWNER'S DESIGN CRITERIA, UTILITY COMPANY REQUIREMENTS, APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY, AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION.

4. THE CONTRACT DRAWINGS DO NOT SHOW EVERY FITTING AND APPURTENANCE FOR EACH UTILITY BECAUSE OF THE SCALE OF THE DRAWINGS. EACH CONTRACTOR SHALL HAVE INCLUDED IN HIS BID SUFFICIENT FITTINGS, MATERIAL AND LABOR TO ALLOW FOR ADJUSTMENT IN ROUTING OF UTILITIES MADE NECESSARY BY THE COORDINATION PROCESS. THE CONTRACTOR WILL NOT BE ALLOWED ANY CONTRACT COST EXTRA OR TIME EXTENSION FOR CHANGES DICTATED BY THE COORDINATION PROCESS.

5. EACH CONTRATOR SHALL NOT SUBMIT SHOP DRAWINGS FOR EQUIPMENT THAT MAY BE AFFECTED BY FINAL RESOLUTION OF ITS COORDINATION DRAWING STATUS AND SHALL NOT BE SUBMITTED UNTILL THE COMPLETION OF DRAWING COORDINATION.

6. CONTRACTOR SHALL LEAVE ALL SPACES, INCLUDING ALL STRUCTURAL SYSTEMS, ROOM FINISHES, FIXTURES, AND EQUIPMENT (WHETHER BUILT IN OR MOVABLE) IN THE SAME GENERAL CONDITION AS IT IS AT THE START OF THE WORK. ALL FIXTURES AND EQUIPMENT MOVED OR DISTURBED IN CONNECTION WITH THE NEW WORK SHALL BE PROPERLY INSTALLED IN THE MANNER CORRESPONDING TO THE ORIGINAL METHOD, AND ALL DAMAGE TO EXISTING FIXTURES AND EQUIPMENT SHALL BE FULLY REPAIRED.

7. MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED BY ARCHITECT / ENGINEER. SUBSTITUTIONS MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE ARCHITECT / ENGINEER.

8. AS-BUILT DRAWINGS-PREPARE AND SUBMIT TO THE OWNER "AS-BUILT" DRAWINGS INDICATING THE EXACT LOCATION OF ALL EQUIPMENT INCLUDING THE EQUIPMENT'S "AS INSTALLED" SIZE(S), MANUFACTURER, MODEL NUMBERS, AND PERFORMANCE RATINGS. ALL NEW UNDERGROUND WORK SHALL BE CAREFULLY DOCUMENTED AND TRANSFERRED TO DRAWINGS TO BE INCLUDED IN THE "AS-BUILT" FINAL DRAWINGS.

9. SUPPORTS - EQUIPMENT, PIPING, DUCTWORK, OR ANY OTHER ACCESSORY SHALL NOT BE SUPPORTED FROM OTHER PIPING, DUCTWORK, METAL ROOF DECK, LATERAL BRACING BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM BUILDING STRUCTURE.

10. CONTRACTOR IS RESPONSIBLE FOR PROPER SUPPORT OF ALL EQUIPMENT, DUCTWORK, ETC. COORDINATE EXACT LOCATION OF ALL DUCTWORK, AIR TERMINAL UNITS, PIPING, ETC. WITH STRUCTURAL, ARCHITECTURAL, ELECTRICAL, REFLECTED CEILING PLANS, AND OTHER MECHANICAL SYSTEMS.

11. WHERE MOUNTING HEIGHTS ARE NOT DETAILED OR DIMENSIONED, INSTALL MECHANICAL SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE MAXIMUM HEADROOM POSSIBLE.

12. ALL DUCTWORK, PIPING, AND TEMPERATURE CONTROL CONDUIT TO VIBRATING EQUIPMENT SHALL HAVE FLEXIBLE CONNECTORS.

13. IDENTIFICATION NAME PLATES SHALL BE PROVIDED ON THE MECHANICAL EQUIPMENT. PIPING SHALL BE PROVIDED WITH LETTERING INDICATING SERVICE AND ARROW SHOWING DIRECTION OF FLOW. COMPLY WITH ASME A13.1 FOR SIZE, LENGTH, COLOR AND VIEWING ANGLES OF IDENTIFICATION DEVICES.

14. CONTRACTOR SHALL BE RESPONSIBLE FOR ONGOING AND FINAL CLEANING.15. ALL HVAC CONTROL WIRING SHALL BE THE TEMPERATURE CONTROL CONTRACTOR'S

RESPONSIBILITY. WIRING TO BE INSTALLED PER NEC AND LOCAL CODES.16. ALL FAN COIL UNITS, AND UNIT HEATERS SHALL HAVE A THERMOSTAT LOCATED IN THE SPACE

THAT IT SERVES. FINAL LOCATIONS SHALL BE COORDINATED WITH OTHER TRADES AND APPROVED BY THE ARCHITECT AND ENGINEER.

17. BEFORE INSTALLATION OF EQUIPMENT CONTRACTOR SHALL VERIFY THAT COILS, TUBES, AND OTHER MAINTENANCE ITEMS FOR EQUIPMENT CAN BE REMOVED WITHOUT INTERFERENCE. CONTRACTOR SHALL PROVIDE ADEQUATE ACCESS TO ALL EQUIPMENT AND RECOMMENDED MAINTENANCE CLEARANCES.

18. MECHANICAL CONTRACTOR IS COMPLETELY RESPONSIBLE FOR PROVIDING ALL PRESSURE AND/OR TEMPERATURE TAPS IN PIPING AS REQUIRED FOR PROPER BALANCING OF ALL SYSTEMS.

19. BEFORE INSTALLATION, EQUIPMENT CONTRACTOR SHALL VERIFY THAT COILS CAN BE REMOVED WITHOUT INTERFERENCE. CONTRACTOR SHALL PROVIDE ADEQUATE ACCESS AND COIL REMOVAL SPACE FOR ALL EQUIPMENT.

20. PROVIDE NECESSARY OFFSETS IN PIPING TO CLEAR ALL STRUCTURAL MEMBERS AND OTHER MECHANICAL & ELECTRICAL WORK.

21. RUN ALL DOMESTIC WATER PIPING AS HIGH AS POSSIBLE.22. RUN MAIN WASTE PIPES BELOW GRADE WITH ONE-FOURTH INCH PER FOOT SLOPE TOWARDS

FLOW UNLESS IT IS NOTED OTHERWISE.23. ALL PLUMBING VENTS SHALL BE TERMINATED MINIMUM OF 1 FOOT ABOVE ROOF. VENT PIPES

SHALL BE FREE FROM DROPS OR SAGS AND EACH VENT SHALL BE PROPERLY GRADED AND CONNECTED AS TO DRIP BACK BY GRAVITY TO THE DRAINAGE PIPE IT SERVES.

24. ALL PENETRATIONS OF FIRE RATED ASSEMBLIES ARE TO BE PROTECTED BY AN APPROVED THROUGH-PENETRATION SYSTEM THAT HAS BEEN TESTED IN ACCORDANCE WITH ASTM E814 'METHODS FOR FIRE TESTS OF THROUGH-PENETRATION FIRE STOPS'. REFER ARCHITECTURAL PLANS FOR FIRE RATED ASSEMBLIES.

25. ALL SUPPLY AIR DUCT TAKE-OFFS TO DIFFUSERS TO BE OF SAME AS DIFFUSER NECK SIZE UNLESS OTHERWISE NOTED ON THE PLANS.

26. COORDINATE WITH ARCHITECT PLAN FOR PREFERRED THERMOSTAT LOCATION (NEXT TO LIGHT SWITCH) FINAL LOCATIONS SHALL BE COORDINATED WITH ENGINEER.

27. DUCTS SIZES INDICATED ON PLANS ARE CLEAR INSIDE DIMENSIONS.28. SEE ARCHITECTURAL CODE PLANS FOR RATED WALLS. PROVIDE FIRE, SMOKE AND COMBINATION

FIRE/SMOKE DAMPERS IN ACCORDANCE WITH IBC 2012. 29. SMOKE DAMPERS SHALL BE CONTROLLED VIA FIRE ALARM SYSTEM. THEY SHALL BE CLOSE UPON

DETECTION OF SMOKE IN THE CORRIDORS. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR ALL CONTROL WIRING.

30. PROVIDE ISOLATION VALVES AT EACH BRANCH AND TAKE OFF PLUMBING PIPING SERVING GROUP OF FIXTURES.

31. EXISTING SYSTEMS SHALL REMAIN FUNCTIONAL DURING CONSTRUCTION. ALL DOWNTIME SHALL BE COORDINATED WITH THE CHURCH PRIOR TO OUTAGE.

32. ACCESS PANELS ARE REQUIRED (MINIMUM 12"X12") FOR ACCESS TO EVERY VALVE, DAMPER, AIR TERMINAL, AND CONTROL SENSORS IF NOT OTHERWISE ACCESSIBLE. ACCESS PANEL SHALL BE APPROVED BY ARCHITECT/ENGINEER.

33. CONTRACTOR TO PROVIDE DUCT TRANSITIONS AS REQUIRED FOR CONNECTION OF DUCTS TO THE MECHANICAL UNITS. VERIFY SIZES FOR FINAL CONNECTION TO THE EQUIPMENT WITH THE EQUIPMENT MANUFACTURER.

34. ALL EXHAUST, SUPPLY AND RETURN RUN-OUTS TO DIFFUSERS, GRILLES, AND REGISTERS WILL HAVE MANUAL BALANCING DAMPERS, EXCEPT WHERE PROHIBITED BY CODE.

35. ALL RECTANGULAR SUPPLY, RETURN, AND EXHAUST AIR ELBOWS SHALL BE SQUARE WITH TURNING VANES OR FILLET RADIUS ELBOWS.

36. REFER TO PLANS FOR ADDITIONAL NOTES.

AIR CONDITIONING AND REFRIGERATION:

D DRAINRL REFRIGERANT LIQUIDRG REFRIGERANT DISCHARGE (HOT GAS)RS REFRIGERANT SUCTIONRDB REFRIGERANT DISCHARGE BYPASS

PLUMBING:

SAN SANITARY WASTEST PRIMARY STORMOST SECONDARY STORMHW DOMESTIC HOT WATERCW DOMESTIC HARD COLD WATERHWC DOMESTIC HOT WATER RECIRC.CD CONDENSATE DRAING NATURAL GASV SANITARY VENTF FIRE SPRINKLERHWS HEATING HOT WATER SUPPLYHWR HEATING HOT WATER RETURN

STANDARD MOUNTING HEIGHTS

THERMOSTATS OR SENSORS (USER ADJ.)CONTROLS (CENTERLINE)

MECHANICAL

48" (ADA) / 60"48" (ADA) / 60"

ALL MOUNTING HEIGHTS ARE GIVEN AS INFORMATION ONLY AND MUST BE VERIFIED WITH CURRENT ADA, CODES AND COORDINATED WITH ARCHITECT. LISTED MOUNTING HEIGHTS ARE STANDARD U.N.O.

MISCELLANEOUS SYMBOLS

MISCELLANEOUS ABBREVIATIONS

A

A AMPSA/C AIR CONDITIONINGACC AIR COOLED CHILLERACCU AIR COOLED CONDENSING UNITAF AMPERE FUSEAFC ABOVE FINISHED CEILINGAFEA AREA FOR EVACUATION ASSISTANCEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAIC AMPERE INTERRUPTING CURRENTAL ALUMINUMAP ACCESS PANELATS AUTOMATIC TRANSFER SWITCHAWG AMERICAN WIRE GAUGE

B

BD BACKDRAFT DAMPER, BLOWDOWNBFF BELOW FINISHED FLOORBKR BREAKERBOD BOTTOM OF DUCTBOP BOTTOM OF PIPEBOS BOTTOM OF STRUCTUREBTU BRITISH THERMAL UNIT

C

C CONDUITCATV CABLE TELEVISION SYSTEMCCTV CLOSED CIRCUIT TELEVISION SYSTEMCFM CUBIC FEET PER MINUTECKT CIRCUITCO CLEANOUTCOA CONDITIONED OUTSIDE AIRCRAC COMPUTER ROOM AIR CONDITIONING UNITCRCU COMPUTER ROOM CONDENSING UNITCT COOLING TOWERCU CONDENSING UNIT

D

DDC DIRECT DIGITAL CONTROLDN DOWNDW DIRECT WASTEDX DIRECT EXPANSION

E

EAT ENTERING AIR TEMPERATUREEBH ELECTRIC BASEBOARD HEATEREC ELECTRICAL CONTRACTOREDB ENTERING DRY BULBEDR EQUIVALENT DIRECT RADIATIONEF EXHAUST FANEPO EMERGENCY POWER OFFESFR EARLY SUPPRESSION FAST RESPONSEETR EXISTING TO REMAINEWB ENTERING WET BULBEWC ELECTRIC WATER COOLER

F

FACP FIRE ALARM CONTROL PANELFBO FURNISHED BY OTHERSFCU FAN COIL UNITFD FIRE DAMPER, FLOOR DRAINFF FINISHED FLOORFHC FIRE HOSE CABINETFL FLOW LINEFLA FULL LOAD AMPSFLR FLOORFPC FIRE PROTECTION CONTRACTORFS FLOOR SINKFSD COMBINATION FIRE/SMOKE DAMPERFVNR FULL VOLTAGE, NON-REVERSING

G

GC GENERAL CONTRACTORGFI GROUND FAULT CIRCUIT INTERRUPTERGFR GROUND FAULT RELAYGND GROUNDGPM GALLONS PER MINUTEGRS GALVANIZED RIGID STEEL

H

HB HOSE BIBBHD HEAD, HUB DRAINHOA HAND/OFF/AUTOMATICHSTAT HUMIDISTATHSZBT HORIZONTAL SINGLE ZONE BLOW THROUGHHSZDT HORIZONTAL SINGLE ZONE DRAW THROUGHHTG HEATINGHTR HEATERHVU HEATING AND VENTILATING UNIT

I

IE INVERT ELEVATIONIG ISOLATED GROUNDIN. WC INCHES OF WATER COLUMNIW INDIRECT WASTE

K

KCMIL 1000 CIRCULAR MILSKV KILOVOLTKVA KILOVOLT AMPSKVAR KILOVOLT AMPS REACTIVEKW KILOWATTKWH KILOWATT HOUR

L

LAT LEAVING AIR TEMPERATURELDB LEAVING DRY BULBLF LINEAR FEETLP LOW PRESSURELRA LOCKED ROTOR AMPSLWB LEAVING WET BULBLWT LEAVING WATER TEMPERATURE

M

MATV MASTER ANTENNA TELEVISION SYSTEMMBH 1000 BTU PER HOURMC MECHANICAL CONTRACTORMCA MINIMUM CIRCUIT AMPACITYMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTERMD MOTORIZED DAMPERMDP MAIN DISTRIBUTION PANELMFR MANUFACTURERMG MOTOR GENERATORMH MANHOLEMLO MAIN LUGS ONLYMSB MAIN SWITCHBOARDMTD MOUNTEDMU MAKE UPMUAF MAKE UP AIR FAN

N

N/A NOT APPLICABLENC NOISE CRITERIANIC NOT IN CONTRACTN/O,N/C NORMALLY OPEN, NORMALLY CLOSED

O

OA OUTSIDE AIROC ON CENTER

P

PDU POWER DISTRIBUTION UNITPH PHASEPIV POST INDICATOR VALVEPNL PANELPRV PRESSURE REDUCING VALVE

Q

QTY QUANTITY

R

RA RETURN AIRRCP REFLECTED CEILING PLANRD ROOF DRAIN, ROUNDREV REVISIONRH RELATIVE HUMIDITYRLA RUNNING LOAD AMPS

S

SA SUPPLY AIRSD SMOKE DAMPERSF SQUARE FEETSOV SHUT-OFF VALVESP STATIC PRESSURESS STAINLESS STEELST STEAM TRAPSTC SOUND TRANSMISSION CLASSSTM STEAM

T

TA TRANSFER AIRTDH TOTAL DYNAMIC HEADTSTAT THERMOSTATTWU THROUGH WALL AIR CONDITIONING UNIT

U

U/F UNDERFLOORU/G UNDERGROUNDUH UNIT HEATERU/S UNDERSLABUL UNDERWRITERS LABORATORY, INC.UNO UNLESS NOTED OTHERWISEUPS UNINTERRUPTIBLE POWER SUPPLY

V

VAC VACUUMVAV VARIABLE AIR VOLUMEVCP VITRIFIED CLAY PIPEVD VOLUME DAMPERVSZBT VERTICAL SINGLE ZONE BLOW THROUGHVSZDT VERTICAL SINGLE ZONE DRAW THROUGHVTR VENT THROUGH ROOF

W

W/ WITHW/O WITHOUTWB WET BULBWCO WALL CLEANOUTWC WATER COLUMNWG WATER GAUGEWHA WATER HAMMER ARRESTORWPD WATER PRESSURE DROPWP WEATHERPROOFWT WATERTIGHT, WEIGHT

X

XFMR TRANSFORMERXP EXPLOSION PROOF

PIPING SYMBOLS

PIPING SYMBOLS (CONTINUED)

X

X

M1

3

M1

1

X

S

BALANCING VALVE

CHECK VALVE

THREE WAY CONTROL VALVE

TWO WAY CONTROL VALVE

SHUT-OFF VALVE

BALL VALVE

BUTTERFLY VALVE

PLUG VALVE

LUBRICATED PLUG VALVE

GLOBE VALVE

STRAINER WITH BLOWDOWN

STRAINER

TRIPLE DUTY VALVE WITH PRESSURE PORTS

SOLENOID VALVE

RELIEF (R) OR SAFETY (S) VALVE

PRESSURE REDUCING VALVE

PRESSURE REGULATING VALVE

GAS COCK

SIGHT GLASS

DIRECTION OF FLOW IN PIPING

PIPING REDUCER (WITH DIRECTION OF FLOW SHOWN)PIPING INCREASER (WITH DIRECTION OF FLOW SHOWN)WALL MOUNTED OXYGEN OUTLET

FLOOR SINK, SIZE AND TYPE

HOSE BIBB

WALL HYDRANT

VENT THROUGH ROOF

CLEANOUT (CO)

WALL CLEANOUT (WCO)

INSULATED FLEXIBLE DUCT (MAXIMUM 4'-0" LONG)

BRANCH DUCT WITH 45 DEGREE TAP AND MANUAL VOLUME DAMPER

BRANCH DUCT WITH MANUAL BALANCING DAMPER

BRANCH DUCT WITH CONICAL FITTING AND MANUAL VOLUME DAMPER

ELBOW WITH TURNING VANES

RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP

RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN

SUPPLY AIR UP

SUPPLY AIR DOWN

RECTANGULAR DUCT (1ST FIGURE = SIDE DOWN)

ROUND DUCT (1ST FIGURE = DIAMETER)

FLAT OVAL DUCT (1ST FIGURE = SIDE DOWN)

RECTANGULAR, ROUND OR OVAL DUCT WITH INTERNAL INSULATION.DIMENSION SHOWN IS CLEAR INSIDE.

FLEXIBLE DUCT CONNECTION

MANUAL VOLUME CONTROL DAMPER

CHANGE OF ELEVATION RISE (R) OR DROP (D)

RECTANGULAR TO ROUND TRANSITION

EQUIPMENT WITH FLEXIBLE DUCT CONNECTION

MANUAL VOLUME CONTROL DAMPER

TRANSITION IN DUCT SIZE

OPPOSED BLADE DAMPER

PARALLEL BLADE DAMPER

MOTORIZED DAMPER DESIGNATION

PNEUMATIC DAMPER DESIGNATION

FIRE DAMPER DESIGNATION

SMOKE DAMPER DESIGNATION

COMBINATION FIRE/SMOKE DAMPER DESIGNATION

THERMOSTAT OR TEMPERATURE SENSOR

PNEUMATIC THERMOSTAT

ROOM HUMIDISTAT

ROOM PRESSURE SENSOR

HUMIDITY SENSOR

MICROPROCESSOR CONTROL

CARBON DIOXIDE SENSOR

TEMPERATURE SENSOR

MARK, CFM AT RETURN GRILLE, SEE SCHEDULE FOR SIZE

MARK CFM AT EXHAUST GRILLE, SEE SCHEDULE FOR SIZE

ROUND/OVAL DUCT RISER

DUCT PRESSURE CLASSIFICATION, FIRST NUMBER INDICATES UPSTREAM PRESSURE, SECOND NUMBER INDICATES DOWNSTREAM PRESSURE. (INCHES W.G. STATIC PRESSURE)

ELBOW UP/DN

TEE UP/DN

ELBOW UP/DN WITH SHUT-OFF VALVE IN RISER

TEE UP/DN WITH SHUT-OFF VALVE IN RISER

TEE/90 DEGREE ELBOW

CAP

UNION

FLANGE CONNECTION

AIR VENT, AUTOMATIC

PITCH OF PIPE, RISE (R) OR DROP (D)

PUMP

PUMP SUCTION DIFFUSER

STRAINER, DUPLEX

PRESSURE/TEMPURATURE TEST PORT

FLOW METER, VENTURI

FLOW METER, ORIFICE

EXPANSION JOINT

FLEXIBLE CONNECTOR

AIR VENT, MANUAL

PRESSURE GAUGE

PRESSURE GAUGE AND COCK

THERMOMETER

FLOW SWITCH

RUNNING TRAP

R

MV

PSD

FS

AV

PIPE GUIDE

4"FS-1

FLOOR DRAIN, SIZE AND TYPE4"FD-1

4"VTR

M

M

FD

SD

FSD

T

T

H

P

H

P

CO2

TS

R

PRESSURE SENSOR

MC

4 3

R-1300

G-1300

12"x10"

12"Ø

30"/24"

BACKDRAFT DAMPER DESIGNATIONBD

GAS DETECTOR SENSORG

INSULATED FLEXIBLE DUCT (MAXIMUM 4'-0" LONG)

BRANCH DUCT WITH 45 DEGREE TAP AND MANUAL VOLUME DAMPER

BRANCH DUCT WITH BELL MOUTH FITTING AND MANUAL VOLUME DAMPER

NOTE:THIS IS A MASTER SYMBOLS LIST. ALL SYMBOLS, ABBREVIATIONS, ETC. MAY NOT NECESSARILY BE USED ON ALL DRAWINGS.

DF-1 DRINKING FOUNTAIN AND TYPE

MS-1 MOP SINK AND TYPE

S-1 SINK AND TYPE

SH-1 SHOWER AND TYPE

EWC-1 ELECTRIC WATER COOLER AND TYPE

CONTROL CONNECTION

AIRFLOW DIRECTION ARROW

VARIABLE AIR VOLUME BOX

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RECIRC.

VENT

WASTE BELOW GRADE

OTHER SUPPLY PIPING (SEE PIPE ABBREVIATION FOR TYPE)

OTHER RETURN PIPING (SEE PIPE ABBREVIATION FOR TYPE)

SECTION CUT:UPPER NUMBER INDICATES SECTION NUMBERLOWER NUMBER INDICATES SHEET NUMBER

DETAIL REFERENCE:UPPER NUMBER INDICATES DETAIL NUMBERLOWER NUMBER INDICATES SHEET NUMBER

PLAN NOTE REFERENCE SYMBOL

REVISION REFERNCE SYMBOL

POINT OF CONNECTION BETWEEN EXISTING WORK TO REMAIN AND EXSITING WORK TO BE REMOVED

CONNECTION POINT BETWEEN NEW WORK AND EXISTING WORK TO REMAIN

RISER DESIGNATION

ITEM TO BE DEMOED

EXISTING TO REMAIN

COMBINATION WYE & EIGHTH BEND/DOUBLE COMBINATION WYE & EIGHTH BEND

COMBINATION WYE & EIGHTH BEND/DOUBLE COMBINATION WYE & EIGHTH BEND WITH CLEANOUT ON OPEN PORT

WYE/DOUBLE WYE

WYE/DOUBLE WYE WITH CLEANOUT ON OPEN PORT

CARBON MONOXIDE DETECTORCO

DENOTES GENERAL ROUTE OF UNDERGROUND PLUMBING CONDUIT. DASH IS CONDUIT ROUTE, DOTS ARE SLAB PENETRATIONS.

WC-1 FLOOR MOUNTED FLUSH VALVE WATER CLOSET AND TYPE

L-1 WALL MOUNTED LAVATORY AND TYPE

L-1 COUNTERTOP LAVATORY AND TYPE

UR-1 URINAL AND TYPE

MARK, CFM AT SUPPLY DIFFUSER, SEE SCHEDULE FOR SIZE

D-1300

DIFFUSER WITH AIRFLOW IN DIRECTION OF ARROW(S)D-1300

ES-1 EMERGENCY SHOWER

FIRE DEPARTMENT INLET CONNECTION

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

8 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

MP001

K19503

10/01/2019

MEC

H/PL

UMBI

NG G

ENER

AL L

EGEN

D

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

MP001

K19503

10/01/2019

MEC

H/PL

UMBI

NG G

ENER

AL L

EGEN

D

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 11: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

9 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

MP002

K19503

10/01/2019

MEC

H/PL

UMBI

NG S

PECI

FICA

TION

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

GENERAL DEMOLITION REQUIREMENTS:

1. ITEMS INDICATED WITH ( E ) ARE EXISTING TO REMAIN. 2. EXISTING INFORMATION INDICATED ON THE DRAWINGS HAS BEEN TAKEN FROM

OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING AND PROVIDE REMOVAL AND/ OR RELOCATION OF EXISTING CONDUITS, CONTRACTORS, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE WITH THE NEW WORK.

3. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. PROVIDE MECHANICAL AND OR PLUMBING DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING SYSTEMS.

4. REMOVE EXISTING UNUSED DUCTS, PIPING, EQUIPMENT, FIXTURES ETC.5. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER, IN

WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE SHALL BE PERFORMED WITH THE OWNERS MAINTENANCE PERSONNEL ADVISED OF SUCH WORK.

6. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATES OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK.

7. IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED IN ANY EXISTING BUILDING COMPONENTS THAT WILL BE DISTURBED DURING THE PROJECT, IMMEDIATELY NOTIFY OWNER/ ARCHITECT PRIOR TO DISRUPTION OF THE MATERIAL.

GENERAL MECHANICAL REQUIREMENTS:

1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK.

2. REVIEW ARCHITECTURAL, MECHANICAL, AND OTHER DRAWINGS FOR ADDITIONAL SCOPE REQUIREMENTS PRIOR TO BID.

3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

4. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE CURRENT ADOPTED EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND STANDARDS.

5. OBTAIN PERMITS AND INSPECTIONS REQUIRED.6. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH

MANUFACTURER’S DETAILS, AND INSTRUCTIONS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED.

7. CONTRACTOR’S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT IN A TIMELY MANNER WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.

8. OBTAIN PERMITS AND INSPECTIONS REQUIRED.9. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH

MANUFACTURER’S DETAILS AND INSTRUCTIONS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED.

10. CONTRACTOR’S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT IN A TIMELY MANNER WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.

11. ALL MATERIAL AND EQUIPMENT CANNOT CONTAIN ANY ASBESTOS, LEAD, MERCURY/MERCURY COMPOUNDS, UREA-FORMALDEHYDE RESIN, OR OTHER RECOGNIZED HAZARDOUS MATERIAL OF ANY KIND OR FORM.

12. OBTAIN PERMITS AND INSPECTIONS REQUIRED.13. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH

MANUFACTURER’S DETAILS AND INSTRUCTIONS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED.

14. CONTRACTOR’S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT IN A TIMELY MANNER WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.

15. MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED AS DESCRIBES IN THESE DOCUMENTS.

DOMESTIC WATER SYSTEMS:

1. DOMESTIC WATER REQUIREMENTS: ALL PIPES, FITTINGS, SOLDER, AND FLUX USED IN THE CONSTRUCTION OF THE DOMESTIC WATER SYSTEM AND THE WETTED SURFACES OF ANY PLUMBING COMPONENT THAT IS IN CONTACT WITH THE DOMESTIC WATER MUST BE CERTIFIED LEAD-FREE IN COMPLIANCE WITH NSF/ANSI 372 “DRINKING WATER SYSTEM COMPONENTS – LEAD CONTENT”.

2. PIPE: ASTM B 88, TYPE L WATER PIPE, DRAWN TEMPER WITH CAST-COPPER SOLDER-JOINT FITTINGS (ASME B16.18, PRESSURE FITTINGS), WROUGHT-COPPER SOLDER-JOINT FITTINGS (ASME B16.22, PRESSURE FITTINGS), OR WROUGHT-COPPER PRESSURE-SEAL FITTING WITH EPDM-RUBBER, O-RING SEAL IN EACH END.

3. DIELECTRIC FITTINGS SHALL BE NIPPLE-TYPE COMPLYING WITH ASTM F1545 AND IAPMO PS-66.

4. SHUT-OFF VALVES IN PIPING: BRONZE, TWO-PIECE, FULL-PORT BALL VALVES COMPLYING WITH MSS SP-110 WITH HANDLEVER.

5. PIPE HANGERS: MSS SP-58, TYPES 1 - ADJUSTABLE, ROUND BOTTOM, STEEL CLEVIS TYPE WITH PLAIN FINISH WITH PLAIN FINISH.

6. HANGERS SHALL BE INSTALLED AT MAXIMUM SPACING AS HEREINAFTER SPECIFIED, EVERY CHANGE IN DIRECTION IN THE PIPE, AND EVERY BRANCH CONNECTION TO EVERY PIPE.

7. HANGER SPACING SHALL BE:- NPS 3/4 AND SMALLER: 60 INCHES WITH 3/8-INCH ROD.- NPS 1 AND NPS 1-1/4: 72 INCHES WITH 3/8-INCH ROD.-NPS 1-1/2 AND NPS 2: 96 INCHES WITH 3/8-INCH ROD.

8. MINERAL-FIBER, PREFORMED PIPE INSULATION: TYPE I, 850 DEG F. MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN COMPLYING WITH ASTM C 547, TYPE I, GRADE A, WITH FACTORY-APPLIED ASJ-SSL. FURNISH AND INSTALL METAL INSULATION SHIELDS AT EACH HANGER. INSULATION FOR COLD WATER SYSTEM SHALL HAVE VAPOR BARRIER.

9. INSULATION SHALL BE CONTINUOUS THRU HANGERS.

WASTE AND VENT SYSTEMS:

1. ALL PIPES SHALL BE INSTALLED WITH MINIMUM SLOPE AS REQUIRED BY CODE.2. HUBLESS CAST-IRON SOIL PIPE AND FITTINGS: PIPE SHALL COMPLY WITH ASTM A

888. SHIELDED COUPLINGS SHALL COMPLY WITH ASTM C 1277 ASSEMBLY OF METAL SHIELD OR HOUSING, CORROSION-RESISTANT FASTENERS, AND RUBBER SLEEVE WITH INTEGRAL, CENTER PIPE STOP.

3. PIPE HANGERS: MSS SP-58, TYPES 1 - ADJUSTABLE, ROUND BOTTOM, STEEL CLEVIS TYPE WITH PLAIN FINISH WITH PLAIN FINISH.

4. HANGERS SHALL BE INSTALLED AT MAXIMUM SPACING AS HEREINAFTER SPECIFIED, EVERY CHANGE IN DIRECTION IN THE PIPE, AND EVERY BRANCH CONNECTION TO EVERY PIPE.

5. HANGER SPACING: NPS 1-1/2 AND NPS 2 - 60 INCHES WITH 3/8-INCH ROD.

PLUMBING FIXTURES:

1. ALL FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS.

2. PLUMBING DESIGNATED AS “ADA” SHALL COMPLY WITH DEPARTMENT OF JUSTICE’S “2010 ADA STANDARDS FOR ACCESSIBLE DESIGN”. FIXTURE WILL BE PROVIDED WITH ALL ACCESSORIES AS REQUIRED TO PROVIDE AN ADA-COMPLIANT INSTALLATION.

3. FIXTURE STOP VALVES/RISERS. STOP VALVE SHALL COMPLY WITH ASME A112.18.1 INCLUDING POLISHED CHROME-PLATED, SOLID BRASS ANGLE STOP WITH ONE-QUARTER-TURN, BALL-TYPE STOP. RISER SHALL BE BENDABLE, POLISHED CHROME-PLATED METAL TUBE WITH SHAPED SEALING HEAD AND BRASS FERRULE.

4. FIXTURE WASTE FITTING: POLYVINYLCHLORIDE (PVC) OR POLYPROPYLENE (PP) TAILPIECE, ADJUSTABLE P-TRAP WITH TUBING DRAIN TO WALL, SLIP-NUTS, AND WALL ESCUTCHEON CONFORMING TO ASTM F 409. INLET AND OUTLET DIAMETER, TAILPIECE LENGTH, AND CONNECTION TO WASTE PIPING RISERS SHALL BE COORDINATED WIT THE FIXTURE.

GAS PIPING:

1. GAS SYSTEM PRIMARY PRESSURE: 14"WC OR LESS.2. GAS PIPE SHALL BE SCHEDULE 40 (TYPE E OR S, GRADE B, ASTM A53) WITH

MALLEABLE-IRON THREADED FITTINGS (ASME B16.3, CLASS 150, STANDARD PATTERN).

3. SUPPORT 1" GAS PIPE ON ROOF WITH PRE-MANUFACTURED ROOF STANDS AT MAXIMUM 84-INCH CENTERS.

4. CONNECT TO RTU WITH GAS COCK, UNION AND MINIMUM 12" DRIP LEG.5. PAINT EXPOSED, EXTERIOR GAS PIPE , VALVE, AND UNION WITH ALKYD SYSTEM

(MPI EXT 5.1D) COMPOSED OF AN ALKYD ANTI-CORROSIVE METAL PRIMER (BASE COAT) AND AN EXTERIOR ALKYD FLAT ENAMEL (TOP COAT). COLOR TO MATCH EXISTING.

DUCT SYSTEMS:

1. DUCT CONSTRUCTION, INCLUDING SHEET METAL THICKNESS, SEAM AND JOINT CONSTRUCTION, REINFORCEMENTS, AND HANGERS AND SUPPORTS, SHALL COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" AND PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED IN "DUCT SCHEDULE" ARTICLE.

2. AIRSTREAM SURFACES IN CONTACT WITH THE AIRSTREAM SHALL COMPLY WITH REQUIREMENTS IN ASHRAE 62.1-2004.

3. DUCT DIMENSIONS SHOWN ARE CLEAR INTERIOR DIMENSIONS.4. DUCTS SHALL BE RATED FOR 1”WG PRESSURE AND COMPLY WITH SEAL CLASS A.5. ALL SUPPLY AND BYPASS DUCTS SHALL BE SINGLE WALL WITH EXTERIOR

INSULATION.6. ALL SQUARE ELBOWS SHALL BE EQUIPPED WITH SINGLE-WIDTH TURNING VANES.7. ALL BRANCH DUCTS TO SINGLE DIFFUSERS SHALL INCLUDE A BALANCING DAMPER

AS CLOSE TO THE DUCT MAIN AS POSSIBLE, UNLESS NOTED OTHERWISE.8. INSULATED, FLEXIBLE DUCT: UL 181, CLASS 1, BLACK POLYESTER FILM

SUPPORTED BY HELICALLY WOUND, SPRING-STEEL WIRE; FIBROUS-GLASS INSULATION; ALUMINIZED VAPOR-BARRIER FILM WITH PLASTIC ZIP-TIES. INSULATION R-VALUE: 6.0.

9. DUCT WRAP: MINERAL OR GLASS FIBERS BONDED WITH A THERMOSETTING RESIN. TYPE II, COMPLYING WITH ASTM C 1290, WITH FACTORY-APPLIED FSK JACKET. MINIMUM 1-1/2 INCHES THICK AND 3/4-LB/CU. FT. NOMINAL DENSITY.

10. EXHAUST DUCT SHALL BE ALUMINUM CONSTRUCTION. EXTERIOR PORTION SHALL BE WATERTIGHT.

11. ALL DUCTS SHALL BE SEAL CLASS A.

MECHANICAL EQUIPMENT:

1. ROOFTOP UNIT (RTU-10): LENNOX KGB030S4DS1P OR APPROVED EQUIVALENT. NOMINAL 2.5 TON UNIT. SUPPLY FAN: 890 CFM @ MINIMUM 0.8" EXTERNAL STATIC PRESSURE, 1/4 HP DIRECT DRIVE UNIT. COOLING: MINIMUM TOTAL/SENSIBLE =30.1 MBH/21.6 MBH AT 80 DEG-FDB/67 DEG-FWB AND 95 DEG-F AMBIENT. SINGLE SCROLL COMPRESSOR. NATURAL GAS HEATING: SINGLE STAGE WITH 65 MBH INPUT/52 MBH OUTPUT. MINIMUM OUTSIDE AIR = 175 CFM. DRY-BULB ECONOMIZER WITH MODULATING OUTSIDE AIR DAMPER AND BAROMETRIC RELIEF DAMPER/HOOD. FILTERS: 2" MERV-8 TYPE. PROVIDE WITH THE FOLLOWING OPTIONS: STAINLESS STEEL HEAT EXCHANGER, COMBUSTION AIR INTAKE EXTENSION AIR INTAKE EXTENSION, VERTICAL VENT EXTENSION KIT, DRAIN PAN OVERFLOW SWITCH, AND COMBINATION COIL/HAIL GUARD. ELECTRICAL: 208 V/1PH/60 HZ, 30 MOP, & 20 MCA. MINIMUM 14" ROOF CURB. INTERNAL DDC CONTROLS TO INTERFACE WITH A CHANGEOVER/BYPASS DAMPER SYSTEM (PROVIDED WITH THE RTU) TO DELIVER VAV SUPPLY AIR TO THE SPACE FROM A CONSTANT AIR VOLUME RTU. PRESSURE DEPENDENT, DUCT-MOUNTED, MOTOR-OPERATED SUPPLY/BYPASS DAMPERS, SPACE TEMPERATURE SENSORS, AND TRANSFORMER FOR CONTROL VOLTAGE WILL BE INCLUDED AS AN INTEGRAL PART OF THE RTU SYSTEM. 24V POWER FOR THE DAMPERS WILL BE PROVIDED FROM THE RTU CIRCUIT. ALL WIRING WILL BE A PART OF THE RTU SYSTEM INSTALLATION AND WILL UTILIZE PLENUM-RATED CABLE ROUTED CONCEALED.

2. CEILING-MOUNTED EXHAUST FAN (EF-1N): GREENHECK SP-B110 OR APPROVED EQUIVALENT. RATED FOR MINIMUM 97CFM @ 0.25"SP. MOTOR: MAXIMUM 1.2 AMP @ 115V/12PH/60HZ. PROVIDE WITH REOSTAT SPEED CONTROLLER FOR BALANCING EXHAUST TO 100 CFM. FAN WILL TURN-ON WITH LIGHTS AND HAVE A 60 DELAY OFF WHEN LIGHTS ARE TURNED OFF.

3. RECESSED, WALL-MOUNTED, ELECTRIC SPACE HEATER (UH-1N): BERKO VFK404F OR APPROVED EQUIVALENT RATED FOR 3 KW (10,230 BTUH) HEAT OUTPUT. FAN-FORCED UNIT WITH INTEGRAL THERMOSTAT AND FACE-MOUNTED TEMPERATURE ADJUSTMENT. ELECTRICAL: 208V/1PH/60HZ AND 14.4 AMPS.

No

.D

ate

Revis

ion

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

MP002

K19503

10/01/2019

MEC

H/PL

UMBI

NG S

PECI

FICA

TION

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion

Page 12: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

M

M

MM

T

T

T

T

M

1. SEE MP001 FOR LEGEND AND ADDITIONAL GENERAL NOTES.2. AFF HEIGHTS ARE TO BOTTOM OF GRILLE.

GENERAL NOTES (THIS SHEET)

1. BYPASS DUCT AND DAMPER SIZED IN ACCORDANCE WITH DAMPER MANUFACTURER'S RECOMMENDATIONS.

2. PROVIDE DBX PRODUCT MODEL DBX 1000-M DRYER VENT BOX. INSTALL PER MANUFACTURES INSTRUCTIONS. INSTALL 4"Ø 26 GAUGE GALVANIZED STEEL DRYER VENT THROUGH ROOF. TERMINATE WITH GOOSENECK DOWN AND COVER VENT WITH BIRDSCREEN.

3. UNDERCUT DOOR 1 INCH ABOVE FINISHED FLOOR.4. 1" FIBERGLASS ACOUSTIC LINER IN RTU-10 RETURN DUCTWORK.5. MINIMUM 18"X12" CEILING ACCESS PANEL FOR DAMPER.

COORDINATE LOCATION WITH ARCHITECT.6. PROVIDE ZONE LINK CONTROLLER.7. DUCT FROM EXISTING TRANSFER AIR OPENING UP TO DISCHARGE

WITHIN PLENUM.8. TRANSFER AIR DUCT THROUGH FULL HEIGHT WALL.9. 12"X24" RA DUCT UP TO RTU-1010. 14"X12" SA DUCT DOWN FROM RTU-10.11. REFERENCE MECHANICAL SPECIFICATIONS ON SHEET MP002 FOR

EF-1N AND UH-1N INFORMATION.

KEY NOTES (THIS SHEET)#

WOMEN'S LOCKER ROOM

201

INVESTIGATIONS OFFICE

202

STORAGE

204

OFFICE

205

INTERVIEW ROOM

203

6"ø EA

UP

D-1

140

R-1

D-1

190R-1

D-2D

50

R-1

D-1

230

D-1

230

D-1

50

(E)2

6"x

12

" S

A

(E)2

6"x

12

" S

A

1

2

3

3

3EF-1N

CORRIDOR

200

14"x12" SA

10"x10" SA

8"x8" SA

8"ø SA

14

"x1

2"

SA

4

24"x12" RA

(E)REGISTER

5

6

(E)36X14 GRILLE

10'-4" AFF

(E)8X8 GRILLE 8'-9" AFF

(E)14X14 GRILLE 7'-6" AFF

(E)14X14 GRILLE 0'-2" AFF

6"ø SA

UH-1N

7 14"x14" RA

22"x12" RA 8

9

10

11

11

1 1

2

(E)2

6"x

12

" S

A

(E)2

6"x

12

" S

A

(E)DIFFUSER(E)DIFFUSER

(E)14X14 GRILLE 8'-3" AFF

(E)8X8 GRILLE 8'-9" AFF

(E)8X8 GRILLE 8'-9" AFF

(E)REGISTER

(E)36X14 GRILLE 10'-4" AFF

(E)14X14 GRILLE 7'-6" AFF

(E)14X14 GRILLE 0'-2" AFF

3' - 0"

3

1. DEMOLISH GRILLE AND CAP WITH SOLID INSULATED SHEET METAL TO MATCH EXISTING.

2. DEMOLISH GRILLE AND PATCH WALL.3. EXISTING GRILLE SHALL DEMOLISHED AND REROUTED TO

DISCHARGE WITHIN PLENUM.

DEMO KEY NOTES (THIS SHEET)X

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

3 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

M101

K19503

10/01/2019

HVAC

SEC

OND

FLOO

R PL

ANS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

SCALE: 1/4" = 1'-0"C3HVAC SECOND FLOOR PLAN

1/4" = 1'-0"A3 HVAC SECOND FLOOR DEMO PLAN

N

N

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

M101

K19503

10/01/2019

HVAC

SEC

OND

FLOO

R PL

ANS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 13: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

FLEXIBLERUN-OUTDUCT

TRANSITION15 DEG. MAX.PER SIDE

AIR FLOW

RECTANGULARBRANCH DUCT

VOLUME DAMPER (TYP.)

RECTANGULAR TAP WITH 45° INLET AND TRANSISTION TO ROUND OR CONICAL SPIN-IN TAP

PROVIDE 90 DEG. MITERED

ELBOWS WITHFACTORY

FABRICATEDTURNING VANES

RECTANGULARTRUNK DUCT

RECTANGULAR BRANCH DUCT

WYE-FITTING WITH TURNING VANES

NOTE:ALL DUCTWORK SHALL BE SEALED IN ACCORDANCE WITH SMACNA FOR SEAL CLASS A. SEE SPEC FOR INSULATION REQUIREMENTS

LOW VELOCITYROUNDBRANCH DUCT

VOLUME DAMPER

CONICAL TRANSITIONTAKE-OFF

LOW VELOCITYRECTANGULARDUCT

LAY-IN T-BAR (SEE ARCH)CEILING (SEE ARCH)

SQUARE DIFFUSER

PLASTIC ZIP TIES

INSULATED FLEX MAX.4' LONG

SPIN-IN BALANCING DAMPER W/LOCKING QUADRANT

INSULATED SHEETMETAL DUCT

INSULATION

NO POP RIVETSALLOWED

NOTE: DIFFUSER TAKEOFF SIZE SHALL BE ONE SIZE LARGE THAN DIFFUSER NECK SIZE

HANGER STRAPS OR UNISTRUT SUPPORTS

1" LINER ENTIRE LENGTH OF DUCT

OPENING TO FACE AWAY FROM

TRANSFER DUCT OPENING

RETURN GRILLE

22"

NOTE:DUCT TO BE 2" LARGER THAN GRILLE CONNECTION (1" LINER ALL SIDES).REFER TO DIFFUSER AND GRILLE SCHEDULE FOR CONNECTION (NECK)SIZE. DUCT TO BE EXTENDED THROUGH WALL IF SHOWN AS SUCH ON PLANS.

24"

18"

18"

12"

24"

12/24 RETURN GRILLE24/24 RETURN GRILLE

24"

30"22"

30"

18"

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

4 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

M501

K19503

10/01/2019

MEC

HANI

CAL

DETA

ILS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

N.T.S.B4 LOW PRESSURE DUCT CONNECTION

N.T.S.A3 ROUND FROM RECTANGULAR TAKE-OFF

N.T.S.C4 TYPICAL DIFFUSER/DUCT CONNECTION

SCALE: 1/8" = 1'-0"A5TRANSFER AIR SOUND BOOT

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

M501

K19503

10/01/2019

MEC

HANI

CAL

DETA

ILS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 14: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

1. SEE MP001 FOR LEGEND AND ADDITIONAL GENERAL NOTES.

GENERAL NOTES (THIS SHEET)

WOMEN'S LOCKER ROOM

201

INVESTIGATIONS OFFICE

202

STORAGE

204

OFFICE

205FD-1

L-1

SH-1

INTERVIEW ROOM

203

WC-1

CORRIDOR

200

2"VUP TO VTR

4"WCO

2"WCO

2"V

SDB-1

2"V

2"V

5

7

WOMEN'S LOCKER ROOM

201

INVESTIGATIONS OFFICE

202

STORAGE

204

OFFICE

205

L-1

SH-1

INTERVIEW ROOM

203

CORRIDOR

200

WC-1

1 2"CW 1 1/4"CW

1"CW

1"HW

1"HW

2

(E)1"

(E)2"

TP-1

3

SDB-1

FD-1

1/2"CW/HW DN

3/4"CW3/4"HW

1. CONNECT TO NEARBY DOMESTIC WATER MAINS. CONTRACTOR SHALL FIELD VERIFY AVAILABILITY AND LOCATION OF NEARBY DOMESTIC WATER PIPES AND COORDINATE ACCESS TO PIPES WITHIN OUT OF SCOPE AREAS WITH OWNER.

2. ACCESS PANEL IN THIS LOCATION FOR WATER HAMMER ARRESTOR.

3. NEW INSULATION FOR EXISTING TO REMAIN PIPE RISERS.4. HW/CW PIPES DOWN TO SDB-1.5. 2"SAN P-TRAP FROM SDB-1 UP TO VENT/DOWN TO SANITARY

MAIN.6. CONNECT TO NEARBY SANITARY PIPE WITHIN FIRST FLOOR

CEILING SPACE. CONTRACTOR SHALL FIELD VERIFY AVAILABILITY AND LOCATION OF NEARBY SANITARY PIPE(S) AND COORDINATE ACCESS TO PIPE(S) WITHIN OUT OF SCOPE AREAS WITH OWNER.

7. FOR THIS LAVATORY, ENSURE SANITARY WASTE TRIM PIPING IS COORDINATED WITH THE ARCHITECTURAL SECTION DENOTING REQUIRED ADA CLEARANCES. PROVIDE DRAIN OFFSET UPSTREAM OF P-TRAP OR OTHER TRIM MODIFICATIONS IF/AS NECESSARY TO MAINTAIN A FULLY COMPLIANT ADA INSTALLATION. SEE DETAIL C1 ON SHEET P501.

KEY NOTES (THIS SHEET)#

4"SAN

2"SAN

2"SAN

UP TO FD-1

UP TO WC-1

UP TO SH-1

UP TO L-1UP TO

SDB-1

2"SAN

6

4"SAN

2"SAN 2"SAN

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:3

3 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

P101

K19503

10/01/2019

PLUM

BING

SEC

OND

FLOO

R PL

AN

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

1/4" = 1'-0"C3 WASTE & VENT SECOND FLOOR PLANN

SCALE: 1/4" = 1'-0"A3WATER & GASES SECOND FLOOR PLAN

SCALE: 1/4" = 1'-0"C1BELOW SECOND FLOOR PLAN

N

N

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

P101

K19503

10/01/2019

PLUM

BING

SEC

OND

FLOO

R PL

AN

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 15: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. IF FLOOR DRAIN/SINK IS MORE THAN 5' ON A 2" WASTE OR 6' ON A 3" WASTE FROM THE PARTITION, PROVIDE A TRAP AND WASTE LINE TWO PIPE SIZES LARGER THAN THE DRAIN/SINK OUTLET, WITH A REDUCER ON THE TRAP INLET, AND VENT WITHIN 15 FEET. OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE.

CONCRETE FLOORMEMBRANE CLAMPING COLLAR & SEEPAGE PAN

MAXIMUM TAILPIECE LENGTH

IS 2'-0"

MAXIMUM 5' ON 2" WASTE OR 6' ON 3"

SLOPE WASTE AT TWO PERCENT

REDUCING TRAP OR FITTINGS

MAXIMUM 15' WHERE ENLARGED WASTE LINE IS USED AS A

COMBINATION WASTE/VENT

SYSTEM.

LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED ARCHITECTURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR DRAIN, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION IS FLOOR SLAB IN GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL IT. SET DRAIN BODY IN PLACE & POUR AROUND IT. RECESS TOP OF FLOOR SINKS 1/2" BELOW FLOOR SURFACE & SLOPE FLOOR TO IT. DO NOT RECESS TOP OF FLOOR DRAINS. IF SITUATION IS FLOOR NOT ON GRADE, REFER TO "FLOOR PENETRATION" DETAIL FOR VENTS.

RECESS FLOOR DRAIN AS NOTED ON ARCHITECTUAL DETAILS.

1

2

3

1

2

3

18" MIN. CLEAR

PANEL OPENING

12" MIN. CLEARPANEL OPENING

1" MIN. CLEAR

1-1/2" MIN. CLEARANCEKEY:1. WATER HAMMER ARRESTER.2. BALL VALVE, SAME NOMINAL SIZE AS PIPE BRANCH IN CHASE. OPENING IN BALL VALVE TO MATCH PIPE ID.3. PIPE SAME SIZE AS BRANCH IN CHASE TO WHICH IT IS ATTACHED.

NOTE:1. PROVIDE REDUCER IF REQUIRED BETWEEN VALVE AND WATER HAMMER ARRESTER.

HOT OR COLD

WATER SUPPLY

WATER HAMMER ARRESTORS

SINGLE/DOUBLE FIXTURE MULTIPLE FIXTURES

IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZES FOR HALF THE FIXTURE UNITS IF HORIZONTAL

BRANCH IS LESS THAN 20' LONG, PROVIDE ONE WHA AT END OF LINE

PDI SIZE PIPE SIZEFIXTURE

UNIT LOAD

A

B

C

D

E

F

1/2"

3/4"

1"

1-1/4"

1-1/2"

2"

1-11

12-32

33-60

61-113

114-154

155-330

FIXTURE UNIT TABULATION

FIXTURE

VALVE WATER CLOSET

TANK WATER CLOSET

URINAL

LAVATORY/SINK

JANITOR'S SINK

SHOWER/BATHTUB

COLD HOT

10 - -

5 - -

5 - -

1.5 1.5

3 3

2 2

NOTES:1. FOR BATTERIES OF FIXTURES, PROVIDE WATER HAMMER ARRESTORS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE #1010 AND ANSI #A112.28.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR THE TABLES SHOWN ABOVE. PROVIDE ACCESSIBILITY TO "WHA" WHERE REQUIRED BY LOCAL CODE.

2. INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS. PROVIDE A WHAT AT ALL QUICK-CLOSING VALVES.

HANGER ROD

HANGER ROD

LOCKING NUT

LOCKING NUT

HEAVY DUTY CLEVIS HANGER

HEAVY DUTY CLEVIS HANGER

SUPPORT NUT

SUPPORT NUTVAPOR BARRIER

INSULATION

PIPE

16 GAUGE ZINC COATED SHEET STEEL SADDLE

SHIELD AT LEAST 12" LONG OR INSERTS

RATED FOR SUPPORT.

SINGLE HORIZONTAL RUNS

WITH VAPOR BARRIER

INSULATION

SINGLE HORIZONTAL RUNS

WITH NO VAPOR BARRIER

INSULATION

INSULATED WHERE SPECIFIC SHALL

BUTT AGAINST PIPE HANGERS

HANGER ROD SCHEDULE

PIPE SIZE

UP TO 2"

2-1/2" - 3"

4" - 5"

6" - 12"

ROD SIZE

3/8" DIA.

1/2" DIA.

5/8" DIA.

7/8" DIA.

USE UNISTRUT P-1100 SERIES PIPE CLAMP FOR PLUMBING PIPE

USE UNISTRUT 1-5/8"x1-5/8" CHANNEL

SUPPORT (TYP.)

SIZE AND QUANTITY OF HANGER RODS SHALL BE AS

RECOMMENDED BY STRUT MANUFACTURER.

UNISTRUT SUPPORT NUT (TYPICAL)

USE 20 GAUGE GALVANIZED 12" LONG METAL SHIELD AROUND

INSULATION

PIPE INSULATION (TYP.)

PLUMBING PIPE (TYP.)

ELECTRICAL CONDUIT (TYP.)

USE UNISTRUT "UNI-CLIP" CLAMP FOR ELECTRICAL CONDUIT

NOTES:1. PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON SAME SUPPORT CHANNEL WHERE PRACTICAL.2. SUPPORT CHANNEL LENGTH SHALL NOT BE DETERMINED UNTIL ALL PIPING AND CONDUIT TO BE SUPPORTED IS COORDINATED.

ROOF INSULATION

ROOF DECK

ANCHOR PIPE TO ROOF DECK OR JOISTS.

MINIMUM 12" ABOVE ROOF NORMALLY. EXTEND TO HEIGHT OF PARAPET WHEN WITHIN 10' OF PARAPET.

FLASHING AND COUNTER-FLASHING OF

INTAKE PIPE IS BY ROOFING CONTRACTOR.

PLUMBING CONTRACTOR TO

COORDINATE INSTALL.

CORE DRILL ROOF OR PROVIDE SLEEVE IF REQUIRED

BY TYPE OF ROOF DECK. PROVIDE FIRESTOP SEAL

BETWEEN PIPE AND SLEEVE OR DECK

REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, OR ONE FOOT FROM ANY VERTICAL SURFACE. LOCATE VTR MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT CURB, ETC. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS.

SLOPE DRAIN TO FLOOR/EQUIPMENT DRAIN

PLUGS

UNION

DRAIN THROUGH HVAC EQUIPMENT CONDENSATE DRAIN PAN

FLOOR 1" MINIMUM

B

A

NOTES:

DRAW THRU COIL CONFIGURATIONA = MAX. NEGATIVE STATIC PRESSUREB = 1/2 MAX. NEGATIVE STATIC PRESSURE + 2"

BLOW THRU COIL CONFIGURATIONA = 0"B = MAX. POSITIVE STATIC PRESSURE + 2"

COPPER PIPING TO DRAIN

COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN.

WASTE OR VENT

PROVIDE CLEANOUT TEE WITH SCREWED COUNTER-SUNK

CAST IRON PLUG: TAPERED-THREAD WITH TFE JOINT

COMPOUND.

WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR

PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS

STEEL COVER W/ BEVELED EDGE. FLOOR

HUB AT FLOOR

RISER LENGTH AS REQ'D

LONG SWEEP AT END OF LINE OR COMBINATION WYE

DIRECTION

OF FLOW

NOTES:1. PROVIDE WCO AT BASE OF ALL RAIN-LEADER DOWNSPOUTS. PROVIDE WCO WHERE SHOWN ON PLANS, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT. LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. REFER TO PLUMBING FIXTURE SCHEDULE FOR FURTHER INFORMATION.2. CLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVIDE EXTENSION IF REQUIRED.

RTU

G(E)

DIRT LEG

G

PROVIDE REGULATOR IF REQUIRED BY RTU MANUFACTURER.

LOCATE SUPPORTS AT THE FOLLOWING:

1. SPACING FOR METAL PIPE: 1/2" = 6', 3/4" OR 1" = 8', 1-1/4" OR LARGER = 10'. PLACE A SUPPORT AS CLOSE AS POSSIBLE TO EACH ELBOW AND TEE. PLACE BASE SHEETS ON ROOFING BEFORE GRAVEL IF ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS AND SCREW THEM TOGETHER WHERE REQUIRED TO ELEVATE PIPING. INSTALL PIPE TO ALLOW FOR EXPANSION AND CONTRACTION.

ROOF INSULATION

ROOF DECK

ROOF TOP BLOX AND 1.5" BLOCK HEIGHT EXTENSION TO PROVIDE MINIMUM 6" CLEARANCE UNDER PIPES. PROVIDE ALL OTHER ACCESSORIES AS REQUIRED TO FACILITATE INSTALLATION.

GALVANIZED PROVIDED WITH ROOF TOP BLOX OR GALVANIZED STEEL CLAMP AS REQUIRED BY PIPE SIZE. DO NOT CLAMP PIPE TIGHT. CLAMP SHALL BE COMPATIBLE WITH PIPE TYPE.

SHEET METAL SCREWS AS RECOMMENDED BY

MANUFACTURER (TYP.)

STRUCTURAL FOAM PROVIDED WITH ROOF TOP BLOX. COORDINATE

INSTALLATION WITH ROOFING CONTRACTOR.

ROOFING

FINISHED WALL

COLD AND HOT WATER SUPPLIES

FINISHED FLOOR

CLEANOUT PLUG

FLOOR DRAIN

COUNTERTOP

P-TRAP

SS BRAIDED PRIMER HOSE

REMOVEABLE PANEL RE:ARCH DETAIL

PROVIDE TRAP ARM OFFSET IF/AS REQUIRED TO MAINTAIN ADA KNEE SPACE.

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:3

6 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

P501

K19503

10/01/2019

PLUM

BING

DET

AILS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

N.T.S.C5 FLOOR DRAIN INSTALLATION

N.T.S.D3 TYPICAL WATER HAMMER ARRESTER PANEL

N.T.S.A5 WATER HAMMER ARRESTOR

N.T.S.B5 CLEVIS HANGER

N.T.S.A3 TRAPEZE PIPE HANGERN.T.S.A1 VENT THROUGH ROOF

N.T.S.C3 HVAC CONDENSATE TRAP

N.T.S.B1 TYPICAL WALL CLEANOUT

N.T.S.D5 RTU NATURAL GAS CONNECTION

N.T.S.B3 PIPE SUPPORT ON ROOF

N.T.S.C1 FLOOR DRAIN TRAP PRIMER

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

P501

K19503

10/01/2019

PLUM

BING

DET

AILS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 16: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

WC-1

L-1

SH-1

2"CW

1 1/4"CW

1"HW

1"HW

1"CW

RM. 201

RM. 201

RM. 201

RM. 201

CONNECT TO NEARBY EXISTING DOMESTIC

WATER MAINS

SDB-1

1"HW1 1/4"CW

RM. 201L-1

SH-1

RM. 201

2"WCO

RM. 202

2"SAN

4"S

AN

2"SAN

2"V

2"V

2"V

2"V

4"WCO

WC-1

FD-1

RM. 201

RM. 201

RM. 201

RM. 201

3"VTR

CONNECT TO NEARBY EXISTING SANITARY PIPE

SDB-1

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:3

8 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

P601

K19503

10/01/2019

PLUM

BING

RIS

ER D

IAGR

AMS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

N.T.S.A5 DOMESTIC WATER RISER

N.T.S.C5 WASTE & VENT RISER

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

P601

K19503

10/01/2019

PLUM

BING

RIS

ER D

IAGR

AMS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 17: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

AIR OUTLET AND INLET SCHEDULE

MARK

D-1

D-2

D-2D

R-1

NOTES:

1.

2

3

MANUF. &

MODEL

TITUS TMS

TITUS TMS

TITUS PAR

BORDER TYPES SHALL BE COMPATIBLE WITH ARCHITECTURAL CEILING TYPE FOR THE ROOM IN WHICH THE AIR DEVICE IS LOCATED. CONTRACTOR TO CONFIRM BORDER TYPE PRIOR TO ORDERING.

PROVIDE WITH FACE OPERATED DAMPER IN AREAS WITH INACCESSIBLE CEILINGS (REFERENCE "D" SUFFIX MARK).

EQUIVALENT MANUFACTURERS ARE KRUEGER, PRICE, CARNES, ANEMOSTAT, NAILOR.

TYPE

LOUVERED SQUARE CEILING DIFFUSER

4-WAY THROW

LOUVERED SQUARE CEILING DIFFUSER

4-WAY THROW

PERFORATED LAY-IN

RETURN / EXHAUST

MODULE

SIZE, IN

24 X 24

12 X 12

24 x 12

24 X 24

NECK SIZE

(W X H OR DIA), IN

6

8

10

12

6

8

SEE PLANS

MAX AIRFLOW

CFM

140

250

380

500

155

220

-

MATERIAL

STEEL

STEEL

STEEL

FINISH

BY ARCH

BY ARCH

BY ARCH

BORDER

LAY-IN OR SURFACE

(REF: RCP)

LAY-IN OR SURFACE

(REF: RCP)

LAY-IN OR SURFACE

(REF: RCP)

PERFORMANCE

MAX. NC

30

30

30

30

30

30

30

30

MAX. SPD, IN

0.10

0.10

0.10

0.10

0.10

0.10

0.10

0.10

NOTES:

1-3

1-3

1-3

PLUMBING FIXTURES AND SPECIALTIES CONNECTION SCHEDULE

GENERAL NOTES:

MARK

CO

WCO

FD-1

AG

TP

WHA

SDB-1

L-1

WC-1

SH-1

A.

B.

C.

D.

FUNCTION

CLEANOUT

PLUG/TEE

WALL CLEANOUT

FLOOR DRAIN

FIXED AIR GAP

TRAP PRIMER

WATER HAMMER

ARRESTOR

SUPPLY/DRAIN

BOX

COUNTERTOP

LAVATORY

(ADA)

FAUCET

WATER CLOSET

(ADA)

HAND SHOWER

AND CONTROL

(ADA)

SHOWER BASE

(ADA)

INSTALL PER MANUFACTURER'S RECOMMENDATIONS.

ALL WATER CLOSET FLUSH VALVE HANDLES SHALL BE LOCATED ON THE TRANSFER SIDE OF THE STOOL.

ALL RESTROOM FAUCETS AND FLUSH VALVES TO BE PROVIDED BY THE SAME MANUFACTURER.

ALL FIXTURES DESIGNATED "ADA" SHALL BE PROVIDED WITH ALL ACCESSORIES AS REQUIRED, INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S

RECOMMENDATIONS/ARCHITECTURAL INSTRUCTIONS, AND COORDINATED WITH ALL OTHER ASSOCIATED ADA REQUIRED FIXTURE COMPONENTS/CLEARANCES FOR

A COMPLETE AND FULLY COMPLIANT ADA INSTALLATION.

MANUFACTURER AND MODEL

WADE 8550: COATED CAST IRON BODY WITH BRONZE TAPER THREADED

COUNTERSUNK PLUG, OR EQUIVALENT.

WADE - 8304 - ROUND STAINLESS STEEL ACCESS COVER WITH CENTER VANDAL PROOF SHCREW

PROVIDE WITH CO PLUG AND TEE, OR EQUIVALENT.

WADE - 1100-A - CAST IRON FLOOR DRAIN WITH FLANGE, INTEGRAL

REVERSIBLE CLAMPING COLLAR, SEEPAGE OPENINGS, 1/2" PLUGGED TRAP

PRIMER TAP, ROUND NICKEL BRONZE ADJUSTABLE STRAINER WITH VANDAL

PROOF SCREWS, FOR LIGHT DUTY (UNDER 2,000 LBS.), OR EQUIVALENT

WADE - 2490 - CAST IRON FIXED AIR GAP, SLIP JOINT INLET WITH SET SCREWS,

TY-SEAL OUTLET, OR EQUIVALENT

WADE - 4401-TS - CAST BRASS P-TRAP BODY, WITH CLEANOUT, 1-1/2" O.D. OUTLET,

CHROME PLATED FINISH, S/S BRAIDED PRIMER TUBE, COMPRESSION TUBE FITTINGS

AND SLIP JOINT INLET, OR EQUIVALENT.

WADE - 5P-100P - CASING SPUN SEAMLESS TYPE L COPPER, MALE PIPE THREAD

CONNECTION, DELRIN PLASTIC RING WITH TWO BUNA O-RINGS, 60 PSI AIR

CHARGE, OR EQUIVALENT

GUY GRAY - B200 - 20 GAUGE BOX, 18 GAUGE FACEPLATE, FURNISH WITH

ONE VALVES, ROUGH OPENING - 10"Wx8-3/4"Hx3-1/2"D, OR EQUIVALENT

ZURN - Z5220: UNDERMOUNT VITREOUS CHINA 19"X16" LAVATORY,

WITH OVERFLOW.

AMERICAN STANDARD - 6500.275 - CHROME PLATED CAST BRASS SPOUT, 0.5 GPM

VANDAL-RESISTANT AERATOR, WIDESPREAD FAUCET, 4" WRISTBLADE HANDLES,

OR EQUIVALENT

AMERICAN STANDARD - 2854.128 - ADA HEIGHT FLOOR MOUNTED TOP SPUD WATER

CLOSET, VITREOUS CHINA, 1.28 GPF ELONGATED FRONT RIM, 2" FULLY GLAZED

TRAPWAY, SIPHON JET FLUSH ACTION, MANUAL PISTON FLUSH VALVE, PRESSURE

VACUUM BREAKER, ADJUSTABLE TAILPIECE, SPUD COUPLING AND FLANGE,

VANDAL-RESISTANT STOP CAP, 1.28 GPF, OR EQUIVALENT.

LEONARD - 7600VP-501P(G): CHROME PLATED BRASS SHOWER VALVE, COMBINATION

THERMOSTATIC/PRESSURE COMPENSATING, INTEGRAL CHECKSTOPS,

4.0GPM MAXIMUM FLOW, PROVIDE WITH 2.5GPM HAND SHOWER, 30" GUIDE

RAIL, SS BRAIDED HOSE AND VACUUM BREAKER, OR EQUIVALENT

COMFORT DESIGNS - SSB 3838BF: BARRIER FREE, SOLID SURFACE

SHOWER BASE. 36"X36" BASE DIMENSION, OR EQUIVALENT.

PROVIDE WITH CHROME PLATED DRAIN COVER.

WASTE

SEE

PLANS

SEE

PLANS

2"

1-1/2"

2"

1-1/2"

4"

2"

VENT

1-1/2"

1-1/2"

2"

1-1/2"

CW

1/2"

SIZES

A THRU F

1/2"

3/8"

1"

1/2"

HW

1/2"

3/8"

1/2"

ELEC.

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:3

0 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

MP701

K19503

10/01/2019

MEC

HANI

CAL/

PLUM

BING

SCH

EDUL

ES

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

MP701

K19503

10/01/2019

MEC

HANI

CAL/

PLUM

BING

SCH

EDUL

ES

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 18: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

1. REFER MP001, AND E001 SHEETS FOR LEGENDS AND ADDITIONAL GENERAL NOTES.

2. LIGHTNING PROTECTION SYSTEM (LPS) IS SHOWN FOR GENERAL SCOPE OF A DELEGATED DESIGN SYSTEM. A COMPLETE LPS SYSTEM IN ACCORDANCE WITH NFPA-780 WITH UL MASTER LABEL SHALL BE PROVIDED FOR THE FACILITY AND ASSOCIATED SYSTEMS.

GENERAL NOTES (THIS SHEET)

1. DASHED CIRCLE DENOTES MINIMUM 10'-0" CLEARANCE FOR OUTSIDE AIR INTAKE. DO NOT PLACE PLUMBING VENTS OR EXHAUST VENTS WITHIN DASHED CIRCLE.

2. 4" DRYER VENT EXHAUST DUCT UP FROM BELOW TERMINATES AT ROOF LINE WITH VENT CAP.

3. DISCHARGE RTU CONDENSATE AT NEARBY EXISTING ROOF DRAIN. SUPPORT PIPING ELEVATED FROM ROOF DECK PER DETAIL B3 ON SHEET P501. USE DWV COPPER PIPING WITH DWV FITTINGS.

4. PROVIDE 30A 2 POLE NEMA 3R DISCONNECT. MOUNT DISCONNECT SWITCH TO EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. WHERE EQUIPMENT MOUNTING IS NOT ALLOWED, PROVIDE CHANNEL-STRUT SECURED TO STRUCTURE ADJACENT TO EQUIPMENT IN ACCORDANCE WITH OWNER REQUIREMENTS. COORDINATE REQUIREMENTS WITH OTHER TRADES PRIOR TO INSTALLATION.

5. PROVIDE WEATHER-RESISTANT, GFCI DUPLEX RECEPTACLE WITH WEATHER PROOF "IN-USE" EXTRA DUTY OUTLET BOX FOR MAINTENANCE PURPOSES. MOUNT TO EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

6. EXHAUST DUCT UP FROM EF-1N. TERMINATE WITH EXHAUST DOME.

7. REFERENCE MECHANICAL SPECIFICATIONS ON SHEET MP002 FOR RTU-10 INFORMATION.

KEY NOTES (THIS SHEET)

EXISTING EXHAUST FAN

EXISTING EXHAUST FAN

EXISTING RTU

EXISTING RTUEXISTING RTU

EXISTING RTU

EXISTING RTU

EXISTING RTU EXISTING RTU

EXISTING RTU

EXISTING RTU

1"G

(E)2" G

1

2

3"VTR

1 1/2"CD

3

17P1

13,15P1

G/WP

4

56

EXISTING SKYLIGHT

(E)3 1/2" G

DN

RTU-10

6"ø EA

7

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

6 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

MEP101

K19503

10/01/2019

MEP

ROO

F PL

AN

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

1/8" = 1'-0"A3 MEP ROOF PLANN

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

MEP101

K19503

10/01/2019

MEP

ROO

F PL

AN

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 19: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

HT

WAP

M

M

T

M

G

G

SPD

GROUND ROD

GROUND CONNECTION WITH TEST WELL

THIS IS A MASTER SYMBOLS LIST. ALL SYMBOLS, ABBREVIATIONS, ETC. MAY NOT NECESSARILY BE USED ON ALL DRAWINGS

20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE

20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE, MOUNTED 6" ABOVECOUNTER AND/OR ABOVE BACKSPLASH, UNLESS OTHERWISE NOTED

20 AMP, 125V, NEMA 5-20R QUAD RECEPTACLE

PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTERSURFACE MOUNTED

PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTERRECESS MOUNTED

SAFETY SWITCH, NON-FUSED, 240V, U.N.O.

COMBINATION STARTER/DISCONNECT (SIZE AS INDICATED)

FUSED DISCONNECT

CURRENT TRANSFORMER, RATED AS SPECIFIED OR REQUIRED

MOTOR

SURGE PROTECTION DEVICE

GROUND CONNECTION

SWITCH, RATING AS SHOWN

FUSE, FUSE AMPACITY AND TYPE AS SHOWN

UTILITY METER (AS REQUIRED BY UTILITY)

CIRCUIT BREAKER, RATING AS SHOWN. LSIG DENOTES ELECTRONIC TRIP UNIT WITH ADJUSTABLE SETTINGS FOR: L= LONG TIME TRIP DELAY, S= SHORT TIME TRIP DELAY, I= INSTANTANEOUS, G= GROUND FAULT

PANEL

TRANSFORMER, TYPE AND RATING AS SHOWN

CONDUIT CONNECTION

CIRCUIT BREAKER WITH GROUND FAULT PROTECTION

FUSE WITH GROUND FAULT PROTECTION

POLE MOUNTED UTILITY TRANSFORMER

RECESSED LUMINAIRE

SURFACE LUMINAIRE

STRIP TYPE LUMINAIRE, LENGTHS AS NOTED ON LUMINAIRE SCHEDULE

EMERGENCY BATTERY LUMINAIRE (2 HEAD) 84" AFF, UNLESS OTHERWISE NOTED

SINGLE POLE SWITCH; 3= THREE WAY SWITCH, 4= FOUR WAY SWITCH, K= KEYSWITCH, D= DIMMER SWITCH, TO= MOTOR THERMAL OVERLOAD SWITCH,T= TIMER, HOA=HAND-OFF-AUTOMATIC, P= PILOT LIGHT, OS= OCCUPANCY SENSOR, VS= VACANCY SENSOR, LVD= LOW VOLTAGE DIMMER, M=MOTOR SPEED CONTROL (SWITCH LOWER CASE LETTER INDICATES DEVICE CONTROL)

WALL MOUNTED LUMINAIRE

RECESSED MOUNTED DOWNLIGHT

A

A

A

WALL MOUNTED LUMINAIRE

WALL WASH LUMINAIRE

A

A

A

A

A

CEILING MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL CHEVRONS AS REQUIRED

WALL MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL CHEVRONS AS REQUIRED

TRACK LUMINAIRE

SINGLE POLE MOUNTED, EXTERIOR LUMINAIRE

DOUBLE POLE MOUNTED, EXTERIOR LUMINAIRE

QUAD POLE MOUNTED, EXTERIOR LUMINAIRE

CEILING FAN

BOLLARD LUMINAIREA

EMERGENCY BATTERY LUMINAIRE (2 HEAD) WITH MOUNTED EXIT SIGN.PROVIDE DIRECTIONAL CHEVRONS AS REQUIRED MOUNT AT 84" AFF, UNLESS OTHERWISE NOTEDA

AA

A A

A

A

A

A

LINEAR PENDANT LUMINAIRE

A

PENDANT LUMINAIREA

RECESSED STEP LIGHT LUMINAIREA

NOTE: UPPER CASE LETTER DENOTES LUMINAIRES TYPE. LOWER CASE LETTER ADJACENT TO LUMINAIRE INDICATES SWITCH THAT CONTROLS LUMINAIRES. HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY POWER. MOUNTING IS NOTED ON LUMINAIRE SCHEDULE

A AMPS, AIR (COMPRESSED)AC ABOVE COUNTER AF FUSE RATINGAFC ABOVE FINISHED CEILING AFEA AREA FOR EVACUATION ASSISTANCE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CURRENT AL ALUMINUM ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE AV AUDIO VISUAL

BFF BELOW FINISHED FLOOR BKR BREAKER BOS BOTTOM OF STRUCTURE BTU BRITISH THERMAL UNIT

C CONDUIT CATV CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUITCLG CEILINGCM COFFEE MAKERCT CURRENT TRANSFORMERCU COPPER, CONDENSING UNITCW CLOTHES WASHER

DN DOWN DPDT DOUBLE POLE, DOUBLE THROW DPST DOUBLE POLE, SINGLE THROW DW DISHWASHER

(E) EXISTINGECD ELECTRIC CLOTHES DRYEREPO EMERGENCY POWER OFFETR EXISTING TO REMAINEWC ELECTRIC WATER COOLER

FBO FURNISHED BY OTHERS FF FINISHED FLOOR FHC FIRE HOSE CABINET FLA FULL LOAD AMPS FLR FLOORFRZR FREEZERFVNR FULL VOLTAGE, NON REVERSING

GD GARBAGE DISPOSALGFI GROUND FAULT CIRCUIT INTERRUPTER

(PERSONAL PROTECTION ON DEVICE) GFP GROUND FAULT PROTECTED FROM UPSTREAMGFR GROUND FAULT RELAY GND GROUND

HOA HAND OFF AUTOMATIC HPS HIGH PRESSURE SODIUM HTG HEATING HTR HEATER

ISCA AVAILABLE SHORT-CIRCUIT CURRENT (AMPS)IG ISOLATED GROUND

KCMIL 1000 CIRCULAR MILS KV KILOVOLT KVA KILOVOLT AMPS KVAR KILOVOLT AMPS REACTIVE KW KILOWATT KWH KILOWATT HOUR

LED LIGHT EMITTING DIODELF LINEAR FEET LRA LOCKED ROTOR AMPS

MATV MASTER ANTENNA TELEVISION SYSTEMMCA MINIMUM CIRCUIT AMPACITYMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTER MD MOTORIZED DAMPER MDP MAIN DISTRIBUTION PANELMFP MULTI-FUNCTION PRINTERMFR MANUFACTURER MH MANHOLE MSB MAIN SWITCHBOARD MTD MOUNTED MW MICROWAVE

(N) NEWN/A NOT APPLICABLE NIC NOT IN CONTRACT N/O,N/C NORMALLY OPEN, NORMALLY CLOSED N/L NIGHT LIGHT

OC ON CENTER OV OVEN

PDU POWER DISTRIBUTION UNIT PH,ø PHASE PJ PROJECTORPLOT PLOTTERPNL PANELPRINT PRINTER (SMALL)PT POTENTIAL TRANSFORMER

QTY QUANTITY

(R) RELOCATEDRA RETURN AIRRANGE RANGE\STOVERCP REFLECTED CEILING PLANREF REFRIGERATOR REV REVISION RH RELATIVE HUMIDITY RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR SD SMOKE DETECTOR SF SQUARE FEET SPDT SINGLE POLE, DOUBLE THROW SPST SINGLE POLE, SINGLE THROW SP STATIC PRESSURE SWBD SWITCHBOARD

TL TWISTLOCK TV TELEVISION TYP TYPICAL

U/F UNDERFLOOR U/G UNDERGROUND U/S UNDER SLAB UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLYUSB RECEPTACLE W/ INTEGRATED USB PORT

VAC VOLTS ALTERNATING CURRENT, VACUUM VM VENDING MACHINE

W/ WITH W/O WITHOUT WP WEATHERPROOF WT WATERTIGHT, WEIGHT

XFMR TRANSFORMER XP EXPLOSION PROOF

SURFACE MOUNTED DOWNLIGHTA

ELECTRICAL SYMBOLS

NOTE: POWER LIGHTING

ONE LINE AND RISER

ABBREVIATIONS

LSIG

400AFRN

800A3P

T-XX

PANELXXX

AUTOMATIC TRANSFER SWITCH

ATS-XX

20 AMP, 125V, NEMA 5-20R SWITCHED DUPLEX RECEPTACLE

20 AMP, 125V, NEMA 5-20R DUPLEX FLOOR RECEPTACLE, 3/4" CONDUITRUN CONCEALED IN FLOOR SLAB

20 AMP, 125V, NEMA 5-20R QUAD FLOOR RECEPTACLE, 3/4" CONDUIT RUNCONCEALED IN FLOOR SLAB

JUNCTION BOX, FLOOR MOUNTED

JUNCTION BOX, WALL MOUNTED

SPECIAL RECEPTACLE, FLOOR MOUNTED, CONFIGURATION AS NOTED ON PLAN

SPECIAL RECEPTACLE, WALL MOUNTED, CONFIGURATION AS NOTED ON PLAN

MOTOR: HORSEPOWER AS INDICATED ON PLANS OR DIAGRAMS

PLUGMOLD, REFER TO DRAWING FOR LENGTHS

COMBINATION DISCONNECT, WITH RECEPTACLE, REFER TO DRAWING FOR SIZE

PHOTOCELL

SAFETY SWITCH, NON-FUSED, 240V, U.N.O.

COMBINATION STARTER/DISCONNECT (SIZE AS INDICATED)

FUSED DISCONNECT

FURNITURE FEED RECEPTACLE, WALL MOUNTED, CONFIGURATION ASNOTED ON PLAN

J

J

20 AMP, 125V, NEMA 5-20R QUAD RECEPTACLE, MOUNTED 6" ABOVECOUNTER AND/OR ABOVE BACKSPLASH, UNLESS OTHERWISE NOTED

ENGINE GENERATORG

20 AMP, 125V, NEMA 5-20R QUAD CEILING RECEPTACLE, 3/4" CONDUIT

20 AMP, 125V, NEMA 5-20R CEILING FLOOR RECEPTACLE, 3/4" CONDUIT

JUNCTION BOX, CEILING MOUNTEDJ

EMERGENCY POWER OFF (EPO) BUTTON

SPECIAL RECEPTACLE, CEILING MOUNTED, CONFIGURATION AS NOTED ON PLAN

## CEILING MOUNTED SENSOR; VS= VACANCY, OS= OCCUPANCY, DL= DAYLIGHT

FIRE ALARM REMOTE ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

SMOKE DETECTOR, ADDRESSABLE PHOTO ELECTRIC

HEAT DETECTOR

DUCT SMOKE DETECTOR, ADDRESSABLE PHOTO ELECTRIC

FIRE ADA ALARM STROBE MOUNTED AT 80" AFF OR 6" BELOW CEILINGWHICHEVER IS LOWERFIRE ADA ALARM HORN MOUNTED AT 80" AFF OR 6" BELOW CEILINGWHICHEVER IS LOWER

FIRE ALARM AUDIBLE AND ADA STROBE LIGHT MOUNTED AT 80" AFF OR 6"BELOW CEILING, WHICHEVER IS LOWER

SMOKE DETECTOR, EARLY WARNING LASER DETECTION

ACCESS CONTROL PANEL

GAS ALARM CONTROL PANEL

FLAME DETECTOR

GAS DETECTOR

FIRE ALARM

HD

FD

G

L

ACP

GACP

FARA

FACP

MAGNETIC DOOR HOLDER

FIRE ALARM TAMPER SWITCH

FIRE ALARM FLOW SWITCH

FIRE ALARM MANUAL PULL STATION, ADDRESSABLE DOUBLE ACTIONF

FS

TS

FIRE ALARM CONTROL MODULE (W/ INPUT/OUTPUT MODULE)RM

DUCT DETECTOR REMOTE INDICATOR ALARM AND TESTRTS

FIRE ADA ALARM STROBE CEILING MOUNTED

FIRE ADA ALARM HORN CEILING MOUNTED

FIRE ALARM AUDIBLE AND ADA STROBE LIGHT CEILING MOUNTED

18"

90"

44"

48"

48"

72"

6"

48"

18"

48"

24"

24"

1@48" AND 1@36"

STARTERS

TELEPHONE (PUBLIC)

TELEPHONE OUTLETS (CENTERLINE)

PANELS (TOP)

SAFETY SWITCHES

CLOCK OUTLETS (CENTERLINE)

RECEPTACLES (GARAGES)

RECEPTACLES (EXTERIOR)

RECEPTACLES IN EQUIP. RMS.

RECEPTACLES (CENTERLINE)

ALARMS, SWITCHES AND CONTROLS (CENTERLINE)

TELEPHONE TERMINAL BOARD (BTM.)

FIRE ALARM PULL STATIONS (HANDLE)

12'-0"

18"

48"

80"

48"

CEILING

48"

36"

12'-0"

48"

PHOTOCELLS

INTERCOMS

TELEVISION OUTLETS

ANNUNCIATION PANELS

INTERCOM (AFEA ONLY)

FIRE ALARM BELLS (EXTERIOR)

EXIT SIGNS (WALL MOUNTED BTM.)

REMOTE INDICATING LIGHT (EQUIP. RMS.)

CONTROLS (FIRE ALARM CONTROL PANEL)

REMOTE INDICATING LIGHT (FIN. AREAS)

STROBES (CENTERLINE) 80"*

ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTSINDICATED ON ELECTRICAL DRAWINGS.

STD. MOUNTING HEIGHTS U.N.O.

KEY NOTE DESIGNATION

SHORT CIRCUIT TAG DESIGNATION

FEEDER TAG DESIGNATION

NEW TO EXISTING CONNECTION

REVISION NUMBER DESIGNATION

MISCELLANEOUS

X

X

XXXX

X

NEW LINEWORK

DEMOLITION LINEWORK

EXISTING LINEWORK

CARBON MONOXIDE DETECTOR

CO

ADA DOOR OPENER. MOUNT @ 48" AFFADA

## WALL MOUNTED SENSOR; VS= VACANCY, OS= OCCUPANCY, DL= DAYLIGHT

TWO WAY COMMUNICATION MASTER STATION

TWO WAY CALL STATION2W

M2W

S

S

C

M

S

CLOCK, 84" (CENTERLINE) A.F.F. OR 8" (CENTERLINE) BELOW CEILINGSTHAT ARE 8'-0" OR LOWER, UNLESS NOTED OTHERWISE.

MICROPHONE OUTLET BOX WITH COVER PLATE, FLOOR MOUNTED,UNLESS OTHERWISE NOTED.

SPEAKER, CEILING MOUNTED

HORN SPEAKER

SPEAKER, WALL MOUNTED, 84" (CENTERLINE) A.F.F. OR 8" (CENTERLINE)BELOW CEILINGS THAT ARE 8'-0" OR LOWER, UNLESS NOTED OTHERWISE.

JUNCTION BOX FOR INSTALLATION OF TV OUTLET. MOUNTED 18" AFF,UNLESS OTHERWISE NOTED. INSTALL 1" CONDUIT FROM BOX TO 3" INTOACCESSIBLE LOCATION ABOVE FINISHED CEILING. COORDINATEMOUNTING HEIGHT WITH ARCHITECT PRIOR TO ROUGH-IN.

JUNCTION BOX FOR INSTALLATION OF COMMUNICATION OR DATA OUTLET,MOUNTED 18" AFF, UNLESS OTHERWISE NOTED. INSTALL 1" CONDUITFROM BOX TO 3" INTO ACCESSIBLE LOCATION ABOVE FINISHED CEILING. PROVIDE (2) RJ-45 JACKS UNLESS NOTED OTHERWISE.

FLOOR JUNCTION BOX FOR INSTALLATION OF COMMUNICATION OR DATAOUTLET. INSTALL 1" CONDUIT FROM BOX CONCEALED IN FLOOR SLAB TOWALL AND TO 3" INTO ACCESSIBLE LOCATION ABOVE FINISHED CEILING.PROVIDE (2) RJ-45 JACKS UNLESS NOTED OTHERWISE.

COMMUNICATIONS

CEILING MOUNTED JUNCTION BOX FOR INSATLATION OF WIRELESS ACCESS POINT. PROVIDE (1) RJ-45 JACKS UNLESS NOTED OTHERWISE.

PANEL NAME / CIRCUIT NUMBER - BRANCH CIRCUITS HOMERUN USE NUMBER 12 AWG WIRE, UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL CONTAIN A GROUND AND NEUTRAL CONDUCTOR, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PROVIDE MULTI-WIRE CIRCUIT HANDLE TIES AS FINAL FIELD INSTALLED WIRING REQUIRES.

CONDUIT AND WIRE CONCEALED, 3/4" UNLESS OTHERWISE NOTED, CONDUIT USED FOR SWITCH LEGS, AND CONDUIT USED FOR CONTROL WIRING

CONDUIT AND WIRE EMBEDDED IN CONCRETE OR BELOW GRADE

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CONDUIT DESIGNATIONS

XX/XXX

CONDUIT CAPPED FOR FUTURE USE

SHUNT TRIPST

0' - 0" SELF-REGULATING HEATED CABLE – LENGTH AS SHOWN IN DRAWINGS. REFERENCE ELECTRICAL/PLUMBING PLANS FOR SPECIFICATION OF COMPLETE HEAT-TRACE SYSTEM. ARROW DENOTES DIRECTION

POWER (SERVICE) POLEPP

SUBSCRIPTS ADJACENT DEVICES INDICATE THE FOLLOWING:

G = GFCIT = TAMER RESISTANTAC = MOUNT 6" ABOVE COUNTER OR BACK SPLASHU = DEVICE WITH USB CHARGING PORT

WP = WEATHER PROOFUC = MOUNT 12" UNDER COUNTERS = LOWER OUTLET IN DUPLEX IS

SWITCHED

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:1

2 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E001

K19503

10/01/2019

ELEC

TRIC

AL G

ENER

AL L

EGEN

D

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E001

K19503

10/01/2019

ELEC

TRIC

AL G

ENER

AL L

EGEN

D

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion

Page 20: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:1

2 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E002

K19503

10/01/2019

ELEC

TRIC

AL S

PECI

FICA

TION

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

GENERAL DEMOLITION REQUIREMENTS:

1. REMOVE BOLD ITEMS INDICATED ON PLAN. ITEMS INDICATED WITH (E) ARE EXISTING TO REMAIN. MAINTAIN CIRCUITING TO EXISTING ITEMS OR RECIRCUIT AS INDICATED ON PLANS.

2. EXISTING INFORMATION INDICATED ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND / OR LIMITED FIELD OBSERVATIONS. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING AND PROVIDE REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, CONDUCTORS, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE WITH THE NEW WORK.

3. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. PROVIDE ELECTRICAL DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS.

4. REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, JUNCTION BOXES, DEVICES, LIGHTS AND ELECTRICAL APPURTENANCES COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, DEVICE AND WIRE SHALL BE REMOVED, RACEWAY ABANDONED, AND BLANK COVER PLATES PROVIDED.

5. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER, IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK.

6. WHERE THE REUSE OF EXISTING RACEWAYS, CONDUCTORS, DEVICES, ETC. IS PERMISSIBLE, VERIFY THE CONDUCTORS ARE CONTINUOUS AND MODIFICATIONS IN THIS PHASE OF WORK WILL NOT RENDER EXISTING DEVICES OR JUNCTION BOXES INACCESSIBLE. RELOCATE JUNCTION BOXES OR DEVICES WHICH ARE MADE INACCESSIBLE FROM WORK PERFORMED. RESUPPORT EXISTING ITEMS AS REQUIRED BY CODE.

7. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ITEMS REMOVED AS PART OF DEMOLITION. REMOVE AND PROPERLY DISPOSE OF DEMOLISHED ITEMS.

8. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATES OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK.

9. IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED IN ANY EXISTING BUILDING COMPONENTS THAT WILL BE DISTURBED DURING THE PROJECT, IMMEDIATELY NOTIFY OWNER/ARCHITECT PRIOR TO DISRUPTION OF THE MATERIAL.

GENERAL ELECTRICAL REQUIREMENTS:

1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK.

2. REVIEW ARCHITECTURAL, MECHANICAL, AND OTHER DRAWINGS FOR ADDITIONAL SCOPE REQUIREMENTS PRIOR TO BID.

3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

4. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE CURRENT ADOPTED EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND STANDARDS.

5. OBTAIN PERMITS AND INSPECTIONS REQUIRED.6. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH

MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT SUPPLIED.

7. CONTRACTOR SHALL REPLACE EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS CONTRACT.

8. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT IN A TIMELY MANNER WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.

9. SYSTEMS SHALL BE COMPLETE, AND READY FOR CONTINUOUS OPERATION.10. ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY UL OR

OTHER RECOGNIZED TESTING FACILITY.11. PROVIDE ALL ELECTRICAL EQUIPMENT WITH A LOCAL DISCONNECTING MEANS. 12. DISTRIBUTION OF POWER, LIGHTS, DATA, AND MISCELLANEOUS SIGNALS

SHALL BE IN CONDUIT. CONDUIT SYSTEMS SHALL CONSIST OF RIGID METAL, EMT, OR A COMBINATION OF THE TWO AS REQUIRED BY APPLICABLE CODES AND STANDARDS. (THREADED IMC SHALL NOT BE USED.)

13. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED AS FULLY RATED.14. FIRE-RATED-ASSEMBLY PENETRATIONS: MAINTAIN INDICATED FIRE RATING OF

WALLS, PARTITIONS, CEILINGS, AND FLOORS AT RACEWAY AND CABLE PENETRATIONS. INSTALL SLEEVES AND SEAL RACEWAY AND CABLE PENETRATION SLEEVES WITH FIRESTOP MATERIALS TO MAINTAIN OR RESTORE THE ORIGINAL FIRE-RESISTANCE RATING OF THE ASSEMBLY.

15. INTERIOR PENETRATIONS OF NON-FIRE-RATED WALLS AND FLOORS: SEAL ANNULAR SPACE BETWEEN SLEEVE AND RACEWAY OR CABLE, USING JOINT SEALANT APPROPRIATE FOR SIZE, DEPTH, AND LOCATION OF JOINT.

16. MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED AS DESCRIBES IN THESE DOCUMENTS.

PANELBOARDS:

1. PANELBOARDS SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION.

2. COMPLY WITH NEMA PB 1 AND NFPA 70. INSTALLATION SHALL COMPLY WITH NECA 1 AND NECA 407.

3. COMPLY WITH NFPA 70.4. SURFACE-MOUNTED, DEAD-FRONT CABINETS WITH DOORS HAVING

CONCEALED HINGES; SECURED WITH FLUSH LATCH WITH TUMBLER LOCK; KEYED ALIKE.

5. PROVIDE BREAKERS AS INDICATED IN THE PANELBOARD SCHEDULE. UNLESS NOTED OTHERWISE, BREAKERS SHALL BE BOLT-ON TYPE, REPLACEABLE WITHOUT DISTURBING ADJACENT UNITS.

6. PANELBOARD LABEL: MANUFACTURER'S NAME AND TRADEMARK, VOLTAGE, AMPERAGE, NUMBER OF PHASES, AND NUMBER OF POLES SHALL BE LOCATED ON THE INTERIOR OF THE PANELBOARD DOOR.

7. PRINTED CIRCUIT DIRECTORY CARD INSIDE PANELBOARD DOOR, MOUNTED IN TRANSPARENT CARD HOLDER.

8. MOUNT TOP OF TRIM 90 INCHES ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED WITH PANELBOARD CABINET PLUMB AND RIGID WITHOUT DISTORTION OF BOX.

9. MOUNT RECESSED PANELBOARDS WITH FRONTS UNIFORMLY FLUSH WITH WALL FINISH AND MATING WITH BACK BOX.

10. STUB FOUR 1-INCH EMPTY CONDUITS FROM PANELBOARD INTO ACCESSIBLE CEILING SPACE OR SPACE DESIGNATED TO BE CEILING SPACE IN THE FUTURE.

11. PERFORM VISUAL AND MECHANICAL INSPECTION INCLUDING CONTINUITY TEST FOR EACH CIRCUIT.

LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES:

1. ALL CONDUCTORS SHALL BE COPPER. MINIMUM CONDUCTOR SIZE IS NO. 12 AWG. MINIMUM INSULATION RATING IS 90°C. FOR NO. 2 AWG AND SMALLER: CONDUCTOR SHALL BE RATED PER THE 60°C TABLE. FOR NO. 1 AWG AND LARGER: CONDUCTOR SHALL BE RATED PER THE 75°C TABLE.

2. CONDUCTOR MATERIAL SHALL BE SOLID FOR NO. 10 AWG AND SMALLER AND STRANDED FOR NO. 8 AWG AND LARGER. INSULATION TYPE SHALL BE THHN-THWN UNLESS NOTED OTHERWISE.

3. DEDICATED NEUTRAL CONDUCTORS SHALL BE USED FOR ALL SINGLE PHASE LOADS. ALL NEUTRAL CONDUCTORS SHALL BE A MINIMUM OF FULL SIZE.

4. PRE-WIRED SYSTEMS SUCH AS TYPE AC (ARMORED CABLE), TYPE MC (METAL-CLAD) AND TYPE NM (NONMETALLIC-SHEATHED CABLE) SHALL NOT BE USED. (EXCEPTION: MC MAY BE USED FOR LIGHTING FIXTURE WHIPS UP TO 6'-0”LONG. THEY MUST BE DEDICATED, NOT DAISY CHAINED TOGETHER.)

5. CURRENT RATING OF THE CONDUCTORS SHALL BE EQUAL TO OR GREATER THAN THE OVERCURRENT PROTECTION RATING PROTECTING THE CONDUCTORS.

6. INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 12 INCHES OF SLACK.

GROUNDING & BONDING:

1. ALL GROUNDING AND BONDING SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE.

2. GROUNDING CONDUCTORS SHALL BE INSULATED COPPER CONDUCTORS. GROUNDING CONDUCTORS LARGER THAN # 8 AWG SHOULD BE STRANDED, AND CONDUCTORS SMALL THAN # 8 AWG SHOULD BE NONSTRANDED (SOLID).

3. COMPLY WITH UL 467 FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT.

RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS:

1. ALL CONDUCTORS SHALL BE INSTALLED IN A RACEWAY SYSTEM COMPLYING WITH NECA REQUIREMENT.

2. INDOOR RACEWAY SHALL BE EMT, RIGID METAL CONDUIT, OR APPROVED SURFACE RACEWAY.

3. EMT SHALL NOT BE USED OUTDOORS, IN WET/DAMP LOCATIONS, OR IN FLOOR CRAWL SPACES. EXPOSED EMT SHALL NOT BE USED BELOW 7 FEET AFF IN AREAS WHERE RACEWAY MAY RECEIVE PHYSICAL ABUSE (SUCH AS HALLWAYS, MECHANICAL ROOMS, STORAGE ROOMS, AND JANITOR CLOSETS), UNLESS THE CONDUIT IS 2” OR LARGER IN DIAMETER.

4. CONDUIT SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE. ATTACHMENT TO OTHER PIPES, CONDUITS, DUCTWORK, ETC. SHALL NOT BE ALLOWED.

5. NO CONDUIT SHALL BE EMBEDDED IN A CONCRETE SLAB. ALL CONDUITS BELOW A SLAB SHALL BE A MINIMUM OF 12” BELOW THE CONCRETE SLAB.

6. ALL EMPTY CONDUITS SHALL CONTAIN A PULL STRING. 7. NON-METALLIC CONDUIT OR BOXES SHALL NOT BE USED.8. ALL METALLIC FITTINGS SHALL BE COMPRESSION TYPE RATED FOR GROUND

CONNECTION.9. ALL EXPOSED CONDUIT INSTALLED IN A FINISHED SPACE SHALL BE PAINTED

TO MATCH THE BACKGROUND.10. CONDUCTORS ORIGINATING FROM A DIFFERENT SOURCE PANEL SHALL NOT

SHARE THE SAME RACEWAY.11. SEPARATE GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL FEEDERS

AND BRANCH CIRCUITS. CONDUIT OR RACEWAY SHALL NOT BE USED AS THE GROUNDING CONDUCTOR, HOWEVER ALL METALLIC RACEWAY SHALL BE ELECTRICALLY CONTINUOUS AND BONDED TO THE GROUNDING CONDUCTOR.

12. FOR BRANCH CIRCUITS, THE MINIMUM CONDUIT SIZE SHALL BE ¾” EXCEPT FOR SWITCH LEGS, LIGHTING WHIPS (SUPPLYING A SINGLE FIXTURE CIRCUIT), AND CONTROL WIRING WHICH MAY BE ½”.

13. DEVICE BOXES SHALL BE MINIMUM 4" SQUARE. BOXES AND COVERS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH BY NEMA.

14. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT AND APPROVED FITTINGS THAT DO NO REDUCE THE USABLE INTERNAL DIAMETER OF THE CONDUIT. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.

IDENTIFICATION FOR ELECTRICAL SYSTEMS:

1. COMPLY NEC REQUIREMENTS AS WELL AS ANSI AND IEEE STANDARDS.2. ALL ELECTRICAL EQUIPMENT SHALL BE IDENTIFIED WITH PERMANENT

ENGRAVED NAMEPLATES. THIS INCLUDES LOCAL DISCONNECTS.3. PROVIDE NEW UPDATED TYPED PANELBOARD DIRECTORIES FOR PANEL

MODIFIED OR INSTALLED AS A PART OF THIS PROJECT.4. ALL WIRING DEVICES SHALL BE IDENTIFIED WITH PANEL NAME AND CIRCUIT

NUMBER.

WIRING DEVICES:

1. ALL RECEPTACLES AND SWITCHES SHALL HAVE A MINIMUM RATING OF 20 AMPS AND SHALL BE COMMERCIAL SPECIFICATION GRADE. WIRING DEVICES FROM LEVITON, HUBBELL, LEGRAND AND COOPER SHALL BE ACCEPTABLE. COMPLY WITH NEMA WD 1.

2. PREFERRED COLOR FOR RECEPTACLES AND SWITCHES IS IVORY. OTHER COLORS MAY BE USED TO MATCH EXISTING DEVICES OR FOR SPECIAL USES.

3. ALL WALL PLATES SHALL BE STAINLESS STEEL.4. THE PREFERRED MOUNTING HEIGHTS, ABOVE FINISHED FLOOR, ARE 48" FOR

SWITCHES, AND 18" FOR RECEPTACLES.5. ALL RECEPTACLES IN RESTROOMS AND SIMILAR WET LOCATIONS SHALL BE

GFCI TYPE. ANY RECEPTACLES WITHIN 6'-0” OF THE EDGE OF THE SINK SHALL HAVE GFCI PROTECTION.

INTERIOR LIGHTING:

1. ENERGY EFFICIENT LED LUMINAIRES SHALL BE USED IN THE PROJECT. MINIMUM CRI SHALL BE 80 OR GREATER.

2. LED FIXTURES SHALL HAVE PLUG IN TYPE DISCONNECT AND BE PROVIDED WITH A MINIMUM 5 YEAR WARRANTY. FIXTURE MANUFACTURER MUST BE ABLE TO PROVIDE CERTIFIED IES LM79 AND TM21 DATA. A. CORRELATED COLOR TEMPERATURE (CCT) = 3500K B. EFFICACY = MINIMUM 90 LM/WATT C. TM21 PROJECTION = MINIMUM 50,000 HOURS AT L70 7.4. D. DRIVER CURRENT = 700MA OR MATCH LED MODULE. DO NOT OVERDRIVE

LED MODULE. E. TEMPERATURE RATING = MINIMUM 25 DEG C (MATCH MAX SPACE

CONDITIONS)3. PROVIDE LOCAL SWITCHING FOR ALL LIGHTING. 4. ALL BATTERY PACKS FOR EMERGENCY LIGHTING SHALL HAVE MINIMUM 90

MINUTES OPERATION. EXIT LIGHTS AND EMERGENCY LIGHTING UNITS SHALL COMPLY WITH UL 924

5. CONNECT EMERGENCY LIGHTING AND EXIT SIGNS AHEAD OF LOCAL SWITCHING.

6. COORDINATE PENDANT HUNG INDUSTRIAL STRIP(S) IN UNFINISHED AREAS WITH PIPING, DUCTWORK, EQUIPMENT, CABLE TRAY, ETC. TO AVOID CONFLICTS. MAKE MINOR ADJUSTMENTS TO LUMINAIRE LOCATIONS AS REQUIRED.

7. RECESSED LIGHT FIXTURES INSTALLED IN GYP. BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO CEILING MATERIAL.

8. FIXTURES RECESSED IN "T-BAR" CEILING SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM WITH HANGER WIRES UP TO STRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED CLIPS. FINAL ELECTRICAL CONNECTION TO FIXTURE SHALL BE MADE WITH FLEXIBLE CONDUIT OR UL LISTED ASSEMBLY.

9. VERIFY TRIM COMPATIBILITY WITH CEILING TYPE INDICATED IN ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO ORDERING LUMINAIRES. MODIFY TRIMS AS REQUIRED TO WORK WITH SPECIFIED CEILINGS.

10. LOSS OF UTILITY POWER SHALL ENERGIZE EMERGENCY EGRESS LIGHTING. COMPONENTS OF SYSTEM SHALL BE UL LISTED FOR EMERGENCY TRANSFER.

11. PROVIDE SUBMITTAL OF LIGHT FIXTURES AND SWITCHES.

No

.D

ate

Revis

ion

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E002

K19503

10/01/2019

ELEC

TRIC

AL S

PECI

FICA

TION

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion

Page 21: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

OS

kL

V

f,g

LV

e LV

c,dLV

aLV

OS

OS

OS

OS

OS

OS

OS

h,jLV

a

J

UP

m

JJ

J

1. SEE E001 AND E002 FOR LEGEND AND ADDITIONAL PROJECT REQUIREMENTS.

2. COORDINATE WITH ARCHITECTURAL DRAWINGS AND ELEVATIONS FOR LOCATIONS AND MOUNTING HEIGHTS OF ALL LUMINAIRES. ARCHITECTURAL DRAWINGS AND ELEVATIONS SHALL TAKE PRECEDENCE WHERE ELECTRICAL DRAWINGS VARY FROM ARCHITECTURAL.

3. EXIT SIGNS AND BATTERY PACKS MUST BE CONNECTED TO "UNSWITCHED" LEG OF THE CIRCUIT.

4. THE LIGHTING CONTROL SYSTEM INCLUDING BUT NOT LIMITED TO WALL SWITCHES, WALL SENSORS AND CEILING SENSORS SHALL BE ACUITY CONTROLS, NLIGHT SYSTEM OR AN APPROVED EQUIVALENT NETWORKED DIGITAL CONTROL SYSTEM. THE SYSTEM SHALL BE ABLE TO ACCEPT REMOTE SIGNALS FROM DISPATCH NOTIFICATION SYSTEM.

5. MANUFACTURERS, MODEL NUMBERS/NAMES, AND SIMILAR INFORMATION INCLUDED IN THESE DRAWINGS ARE PROVIDED AS BASIS OF DESIGN INFORMATION. APPLICATION FOR SUBSTITUTING OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED AS DESCRIBES IN THESE DOCUMENTS.

GENERAL NOTES (THIS SHEET)

1. REFER TO DETAIL C1 ON THIS SHEET FOR CEILING FAN AND LIGHT INFORMATION AND ASSOCIATED CONTROLS.

2. CENTER VANITY FIXTURE ABOVE MIRROR. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.

3. PROVIDE JUNCTION BOX FOR RP LIGHTING 1078-E26 CONTEMPO I CEILING FAN WITH INTERGRATED LED LIGHT. CONTROL FAN AND LIGHT VIA WALL SWITCH AS INDICATED. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. REFER TO LUMINAIRE SCHEDULE ON SHEET E701 FOR ADDITIONAL INFORMATION.

4. PROVIDE 20A SINGLE POLE TOGGLE DISCONNECT. CONTROL WITH OCCUPANCY SENSOR CONTROLLING THE LIGHTS IN THAT SPACE. REFER TO DETAIL C4 ON THIS SHEET FOR LOCATION OF OCCUPANCY SENSOR.

5. PROVIDE STANDALONE SMOKE DETECTOR WITH SOUNDER BASE.

6. DOUBLE DUPLEX RECEPTACLE SHALL BE HALF SWITCHED. RIGHT DUPLEX IN 2 GANG BOX IS SWITCHED. USB OUTLET SHALL REMAIN UNSWITCHED. PROVIDE 2-GANG WALLPLATE.

KEY NOTES (THIS SHEET)#

WOMEN'S LOCKER ROOM

201

INVESTIGATIONS OFFICE

202

STORAGE

204

OFFICE

205

CORRIDOR

200

INTERVIEW ROOM

203

D3

D1E

D1D1D1

D1 D1

D1E

D2

D2

W1

R1E

S1

a

fg

j

R2Eh

c

c

c c

d

d

d

e

k

k

X1

X1

c

1

2

6P1

R1

R1E

R1

R1 R1E R1

f

g

g

A

RENOVATION BOUNDARY. RE: ARCHITECTURAL DOCUMENTS.

a a a

A. REMOVE ALL ELECTRICAL DEVICES TO INCLUDE RECEPTACLES, DATA OUTLETS, SWITCHES, ETC, LIGHTING AND ASSOCIATED CONTROLS IN THIS SPACE. REMOVE WIRE AND CONDUITS BACK TO SOURCE OR BACK TO NEAREST EXISTING TO REMAIN JUNCTION BOX WHEN DEVICES ARE PART OF CIRCUITS THAT SERVES OUT OF SCOPE AREA. ANY DEVICES AND PART OF SYSTEMS THAT SERVE AREAS BEYOND THE RENOVATION BOUNDARY SHALL BE MAINTAINED AND RESTORED IF INTERRUPTED.

DEMO KEY NOTES (THIS SHEET)X

WOMEN'S LOCKER ROOM

201

INVESTIGATIONS OFFICE

202

STORAGE

204

OFFICE

205

INTERVIEW ROOM

203

CORRIDOR

200

U/S

TV/72"

U

G

G

AC/G

P1

CF-1m

1P1 3P1 5P1

2P1

9P1

7P1

6P1

3

11P1

NEMA10-30R/36"

10,12P1

8P1

6P1(PART)

4

55

4P1

EF-1N

14,16P1

UH-1N

6

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:1

4 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E101

K19503

10/01/2019

ELEC

TRIC

AL S

ECON

D FL

OOR

PLAN

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

1/4" = 1'-0"C4 SECOND FLOOR LIGHTING PLANN

1/4" = 1'-0"A3 SECOND FLOOR DEMO PLANN

1/4" = 1'-0"C1 SECOND FLOOR POWER PLANN

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E101

K19503

10/01/2019

ELEC

TRIC

AL S

ECON

D FL

OOR

PLAN

S

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 22: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

STRUCTURAL UNIT(BEAM, JOIST, SLAB, ECT.)

ALL THREAD, SIZE AS REQUIRED

RACEWAY -3/4" THRU 6"CONDUIT HANGER

SUPPORT AS REQUIRED BY WEIGHT SUPPORTED.

RACEWAY - 3/4" THRU 6"

STRUCTURAL UNIT(BEAM, JOIST, SLAB, ECT.)

BEAM CLAMP, HANGER CLAMP OR APPROVED SUPPORT, AS REQUIRED BY WEIGHT SUPPORTED.

STRUCTURAL UNIT(BEAM, JOIST, SLAB, ECT.)

BEAM CLAMP, HANGER CLAMP OR APPROVED SUPPORT, AS REQUIRED BY WEIGHT SUPPORTED.

RACEWAY -3/4" THRU 6"

RACEWAY -3/4" THRU 6"

NOTE:1. NO CONDUITS SHALL BE INSTALLED WITHIN 6" OF ROOF

DECKING.

WHEN INTERMEDIATE CEILING SYSTEMS ARE USED, NO 12 GA. (2.7MM) HANGERS SHALL BE ATTACHED TO THE GRID MEMBERS WITHIN 3 INCHES (78MM)OF EACH CORNER OF

EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE COMMON WIRES.

WHEN HEAVY-DUTY CEILING SYSTEMS ARE USED, SUPPLEMENTAL HANGER ARE NOT REQUIRED IF A 48-INCH

(1219 MM) MODULAR HANGER PATTERN IS FOLLOWED. WHEN CROSS RUNNERS ARE USED WITHOUT

SUPPLEMENTAL HANGERS TO SUPPORT LIGHTING FIXTURES, THESE CROSS RUNNERS SHALL PROVIDE THE

SAME CARRYING CAPACITY AS THE MAIN RUNNER.

LIGHTING FIXTURES WEIGHING LESS THAN 56 LBS (25.4 KG) SHALL HAVE FOUR NO. 12 GA. (2.7 MM) HANGER CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK.

LIGHTING FIXTURES WEIGHING 56 LBS (25.4 KG) OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY FOUR NO. 12 GA. (2.7 MM) HANGERS.

ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENED CEILING SYSTEM.

THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE LIGHTING

FIXTURE WEIGHT ACTING IN ANY DIRECTION. SELF TAPPING SHEET METAL SCREWS OF APPROVED EARTHQUAKE CLIPS MAY BE USED. (ONE IN EA.

CORNER.)

MAIN-RUNNERS

RECESSED FIXTURE

CROSS RUNNERS

INSTALL MAXIMUM OF 50 CABLE PER J-HOOK. PROVIDE ADDITIONAL ROWS AS REQUIRED. BUNDLE LIKE COLORED CABLES TOGETHER THEN INSTALL IN J-HOOKS.

SECURITY CABLES

CATV/NC CABLES

4' MAX

SLAB

2" MINDATA AND VOICE CABLES

THREADED ROD

BRACKET SHOT ONTO SLAB WITH POWER NAIL GUN

LOCATIONS WHERE USED:CORRIDORS, LARGE OFFICES, EXAM ROOMS,LARGE TOILET ROOMS, LOCKER ROOMS, LARGERESTROOMS, RECORDS, COPY, STORAGE, AND/ORROOMS/AREAS WITH SWITCHES WITHA "LV" SUFFIX.

120/277V

HOT BLK

NEUTRAL WHT

RED LIGHTINGLOAD

ROOM CONTROLLER

LOAD 1

TO OTHER DEVICES

IN CONDUIT TO ABOVEACCESSIBLE CEILING

1 BUTTON SWITCHES

BUTTON 1 - ON/OFF

LMRJ SERIES PRE-TERMINATED CABLES OR CAT5E.FREE TOPOLOGY & SPLITTER ACCEPTABLE.

TO ADDITIONAL ROOM CONTROLLERS DEPENDING ONCIRCUIT LOAD & FUNCTIONALITY TO SPAN MULTIPLE

CIRCUITS WITH ONE MEANS OF CONTROL OR FORZONES OF CONTROL.

MOUNT TO J-BOX

SPLITTER

RJ 45(TYPICAL)OCCUPANCY SENSOR

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:1

5 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E501

K19503

10/01/2019

ELEC

TRIC

AL D

ETAI

LS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

N.T.S.B5 TYPICAL RACEWAY SUPPORT METHODS

N.T.S.A5 TYPICAL LAY-IN FIXTURE MOUNTINGN.T.S.A2 J-HOOK ASSEMBLY

N.T.S.B2 OCCUPANCY SENSOR DETAIL

No.

Date

Revision

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E501

K19503

10/01/2019

ELEC

TRIC

AL D

ETAI

LS

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:No.

Date

Revision

Page 23: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

T

T

T

T

EXISTINGMAIN SWITCHBOARD: 800A, 480Y/277V, 3P, 4W65 kAICSERVICE ENTRANCE RATEDLOCATION: BASEMENT

EXISTING LDP: 800A, 208Y/120V, 3P, 4W200 kAICLOCATION: BASEMENTSEE DETAIL C3, THIS SHEET

TO POLE MOUNTED UTILITY TRANSFORMER

40

0A

3P

ET

R

10

0A

3P

NE

W

80

0A

3P

ET

R

80

0A

3P

ET

R

EXISTING TX-LDP:300KVA

NEWPNLBD P1

100A208Y/120V3PH, 4W

ETR

ET

R

10

0A

4

PEAK LOAD: 145A / DAYPEAK LOAD IS BASED ON THE HIGHEST USAGE MONTH WITH 78560 KWH OF THE 24 MONTH PERIOD GIVEN.

INSTALL NEW BREAKER IN EXISTING SPACE

THE MAXIMUM AVAILABLE 3-PHASE SYMMETRICAL FAULT CURRENT VALUE AT THE UTILITY TRANSFORMER SECONDARY/POINT OF SERVICE COULD NOT BE DETERMINED PRIOR TO THIS SUBMITTAL. THE ESTIMATED WORST CASE VALUE OF 13,245 A FOR PANEL "P1" IS BASED ON THE EXISTING UPSTREAM EQUIPMENT RATING OF 200,000 A OF PANELBOARD "LDP".

THREE PHASE 4SINGLE PHASE 3

PROTECTION DEVICE

RATING (AMPS)

OVERCURRENT REQUIRED

CONDUCTOR

SIZE

GROUNDING

EQUIPMENT

CONDUCTOR SIZE CONDUIT SIZE

SINGLE PHASE 2

WIRE + GND.WIRE + GND.

CONDUIT SIZEWIRE + GND.

CONDUIT SIZE

THREE PHASE 3

CONDUIT SIZE

WIRE + GND.

BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT SIZE

50

100

SCHEDULE NOTES:1. USE THESE SIZES FOR ALL CIRCUITS UP TO 100A UNLESS NOTED OTHERWISE IN THE DRAWINGS. WHERE A DIFFERENT SIZE

IS INDICATED IN MECHANICAL/ELECTRICAL CONNECTION SCHEDULE, LARGER SIZE SHOULD BE USED.2. CONDUIT SIZES DO NOT APPLY TO 'MC' CABLES. REFERENCE SPECIFICATIONS AND DRAWINGS FOR LIMITATIONS ON 'MC'

CABLE USE.3. ALL CONDUCTORS SIZES ON THE ELECTRICAL ONE-LINE DIAGRAM OR IN THE BRANCH CIRCUIT CONDUCTOR TABLE ARE

BASED ON 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY OR CABLE. CONDUCTORS SHALL BE DERATED IN ACCORDANCE WITH THE NEC IF 4 OR MORE CURRENT CARRYING CONDUCTORS ARE PLACED IN A RACEWAY OR CABLE.

60

70

80

90

30

35

45

40

20

15

25

10 AWG6 AWG

1 AWG

3 AWG

4 AWG

4 AWG

2 AWG

8 AWG

10 AWG

8 AWG

8 AWG

8 AWG

10 AWG

8 AWG

6 AWG

8 AWG

10 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

10 AWG

12 AWG

12 AWG

10 AWG

3/4"3/4"

1-1/4"

1"

1"

1"

1"

1-1/2"

1-1/4"

1-1/4"

1"

1"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

circuit)

(where noted on

3/4"

3/4"

3/4"

1"3/4"

1-1/2"

1-1/4"

1-1/4"

1"

1"

1-1/2"

1-1/4"

1-1/4"

1-1/4"

1-1/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

1"

3/4"

circuit)

(where noted on

3/4"

3/4"

3/4"

FEEDER SCHEDULE

FEEDERTAG

SETS PHASE(& NEUTRAL)

EQUIPMENTGROUND

CONDUIT

1-1/2"100A4 (4) #2 #8

SCHEDULE NOTES:

1. THIS FEEDER SCHEDULE IS BASED ON 60 DEGREE CENTIGRADE WIRE AND TERMINATIONS FOR SIZES #12 TO #1, AND 75 DEGREE CENTIGRADE WIRE AND TERMINATIONS FOR SIZES GREATER THAN OR EQUAL TO #1/0.

2. CONDUIT SIZES ARE BASED ON THHN-THWN WIRE IN RIGID METALLIC CONDUIT.

3. PER NFPA 70, [310.15(B)(5)(c)], THE NEUTRAL CONDUCTOR IS CONSIDERED A CURRENT-CARRYING CONDUCTOR. WHERE THE NUMBER OF CURRENT-CARRYING CONDUCTORS IN A RACEWAY OR CABLE EXCEEDS THREE, THE ALLOWABLE AMPACITY OF EACH CONDUCTOR SHALL BE DE-RATED AS SHOWN IN TABLE 310.15(B)(3)(a). THE FEEDER SCHEDULE REFLECTS THESE DE-RATED AMPACITIES.

1. ALL FEEDERS AND BRANCH CIRCUIT WIRING SHALL BE COPPER CONDUCTORS. UTILIZE SOLID CONDUCTORS FOR #10 AWG AND SMALLER, AND UTILIZE STRANDED CONDUCTORS FOR #8 AWG AND LARGER.

2. PANELBOARDS INDICATED ON ONE-LINE DIAGRAM DO NOT SHOW ALL BRANCH CIRCUITS. REFER TO PANELBOARD SCHEDULES FOR MORE INFORMATION.

GENERAL NOTES (THIS SHEET)

INSTALL NEW BREAKER.

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:1

7 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E601

K19503

10/01/2019

ELEC

TRIC

AL R

ISER

DIA

GRAM

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

N.T.S.C4 PARTIAL ELECTRICAL ONE-LINE DIAGRAM

1" = 10'-0"A5 KEY PLAN

AREA OF SCOPE

DATA RACK TO SERVE LOW

VOLTAGE CABLING FOR INSCOPE

AREA.

No

.D

ate

Revis

ion

N.T.S.C1 EXISTING PANEL LPD

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E601

K19503

10/01/2019

ELEC

TRIC

AL R

ISER

DIA

GRAM

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion

Page 24: SHEET INDEX KCK FIRE DEPARTMENT HQ REMODEL FD … · 2012 international fire code 2009 international energy code ... fec fire extinguisher cabinet fe fire extinguisher ff finish face

LUMINAIRE SCHEDULE INFORMATION

LUMINAIRE TYPE KEYB EXTERIOR BOLLARDSC COVED DOWNLIGHTG IN-GRADE LIGHTINGP PENDANTR RECESSEDS STRIPT TRACK LIGHTINGU UNDER CABINETV SURFACE MOUNTEDW WALLX EXIT SIGNZ EXTERIOR AREA LIGHTS MOUNTED ON POLES

VARIATIONS OR OTHER FEATURES (SUFFIX)

D LUMINAIRE WITH DIMMING DRIVER OR BALLAST

GENERAL NOTES:A. LUMINAIRE MANUFACTURER WITH '*' ARE THE BASIS OF DESIGN FIXTURE FOR WHICH

THE CATALOG NUMBERS ARE LISTED. SIMILAR BY OTHER LISTED MANUFACTURERS ARE ACCEPTABLE. OTHER ACCEPTABLE MANUFACTURERS ARE FOCAL POINT, PRUDENTIAL, PHILIPS DAYBRITE, PHILIPS GARDCO, PHILIPS LIGHTOLIER, WILLIAMS, KENALL, PHILIPS CHLORIDE, DUAL-LITE, FAIL-SAFE.

B. CONTRACTOR TO VERIFY LUMINAIRE CATALOG NUMBER AND INSTALLATION REQUIREMENTS PRIOR TO OPENING.

C. VERIFY TRIM COMPATIBILITY WITH CEILING TYPE PRIOR TO SUBMITTALS.

D. COORDINATE WALL MOUNTING HEIGHTS WITH ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS.

E.

SCHEDULED NOTES:1. REFERENCE FLOOR PLANS FOR CHEVRONS, LOCATIONS, AND TYPES.

PACKAGING OF LUMINAIRES AND LIGHTING CONTROLS IS PROHIBITED. PROVIDE LINE ITEM PRICING FOR ALL LUMINAIRES. PROVIDE LINE ITEMS PRICING FOR ALL LIGHTING CONTROLS.

7400 College Blvd, Ste. 150

Overland Park, KS 66210

Phone/Fax: 913-951-8311

www.branchpattern.com

JOB #:

BETTER BUILT ENVIRONMENTS

08'

16'

32'

06"

1'3"

01'

2'6"

3"0

6"1'

2'0

1'2'

3'0

1'2'

4'0

2'4'

6'0

2'4'

8'4'

08'

16'

Project No.

Date

D

B

A

1 2 3 4 5 6

1 2 3 4 5 6

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

SC

AL

E:

1/1

6"

= 1

'-0

"S

CA

LE

: 1

/8"

= 1

'-0

"S

CA

LE

: 1

/4"

= 1

'-0

"S

CA

LE

: 3

/8"

= 1

'-0

"S

CA

LE

: 1

/2"

= 1

'-0

"S

CA

LE

: 3

/4"

= 1

'-0

"S

CA

LE

: 1

" =

1'-

0"

SC

AL

E:

1 1

/2"

= 1

'-0

"S

CA

LE

: 3

" =

1'-

0"

C

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

963.005

10/1

/201

9 4

:30:2

0 P

M

\\m

eg.local\share

s\o

ma

ha\H

om

e D

rives\a

bhin

av.p

\Docum

ents

\My R

evit P

roje

cts

\ME

G_K

CK

FD

HQ

Rem

ode

l_M

EP

19_abh

inav.p

.rvt

E701

K19503

10/01/2019

ELEC

TRIC

AL S

CHED

ULES

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:

LUMINAIRE SCHEDULE

TYPE OFFIXTURE DESCRIPTION

MANUFACTURER* ORAPPROVED EQUIVALENT CATALOG SERIES NUMBER LAMPS LAMP CCT CRI INPUT VA VOLTAGE

D1 6" DIAMETER WET LOCATION LED LENSEDDOWNLIGHT

LITHONIA*, METALUX,COLUMBIA

LDA6-35/25-L06AR-XX-MVOLT-GZ10 LED 3500 K 80 27 VA 120 V

D1E 6" DIAMETER WET LOCATION LED LENSEDDOWNLIGHT WITH 90 MINUTE BATTERYBACKUP

LITHONIA*, METALUX,COLUMBIA

LDA6-35/25-L06AR-XX-MVOLT-GZ10-E10WCP

LED 3500 K 80 27 VA 120 V

D2 6" DIAMETER GALVANIZED STEELDOWNLIGHT WITH SCREW-IN LED. LABELFIXTURE HOUSING TO SAY "LED BULB ONLY"

LITHONIA*, WILLIAMS,COLUMBIA

6VI-609-SDT (1) SYLVANIA ULTRALED 79491

2700 K 80 15 VA 120 V

D3 6" DIAMETER NON-CONDUCTIVE SHOWERLIGHT

GOTHAM*, WILLIAMS,COLUMBIA,PATHWAY-COVENTRY

EVO 35/20 6 DFR MVOLT LED 3500 K 85 30 VA 120 V

R1 RECESSED 24" X 48" LOW-PROFILE LEDEDGE-LIT FLAT PANEL

LITHONIA*, WILLIAMS,COLUMBIA,PHILIPS-DAY-BRITE

EPANL-2X4-4000LM-80CRI-35K-MIN10-ZT-MVOLT

LED 3500 K 82 39 VA 120 V

R1E RECESSED 24" X 48" LOW-PROFILE LEDEDGE-LIT FLAT PANEL WITH 90 MINUTEBATTERY BACKUP

LITHONIA*, WILLIAMS,COLUMBIA,PHILIPS-DAY-BRITE

EPANL-2X4-4000LM-80CRI-35K-MIN10-ZT-MVOLT-E10WCP

LED 3500 K 82 39 VA 120 V

R2E RECESSED 24" X 24" LOW PROFILE LEDEDGE-LIT FLAT PANEL WITH 90 MINUTEBATTERY BACKUP

LITHONIA*, WILLIAMS,COLUMBIA

EPANL-2X2-3400LM-80CRI-35K-MIN10-MVOLT-E10WCP

LED 3500 K 80 31 VA 120 V

S1 48" LONG LINEAR LENSED STRIP LIGHT LITHONIA*, METALUX,PHILIPS-DAY-BRITE,COLUMBIA

CLX L48 5000LM SEF WDL 120V GZ1035K 80CRI

LED 3500 K 80 35 VA 120 V

W1 24" WALL MOUNTED CONTEMPORARY WALLBRACKET WITH STANDARD DIMMING DRIVER

LITHONIA*, WILLIAMS FMVCCLS-24-MVOLT-90CRI-XX LED 2700 K 90 27 VA 120 V

X1 DIE-CAST ALUMINUM STENCIL FACE SINGLESIDED EXIT SIGN, FIELD SELECTABLEDIRECTIONAL CHEVRONS, 90 MINUTEBATTERY

LITHONIA*, WILLIAMS,DUAL-LITE, PHILIPS

LE-S-1-R-EL N LED NA 11 VA 120 V

(G) - GFCI TYPE BREAKER(LCK) - PROVIDE PAD-LOCKABLE OFF DEVICE

Notes:

A Appliance

E Equipment 13800 VA 100.00% 13800 VA Spare Capacity: 44 A

LM Largest Motor Total Est. Demand: 56 A

M Motor Total Conn.: 55 A

R Receptacle 5220 VA 100.00% 5220 VA Total Est. Demand: 20156 VA

C Continuous Total Conn. Load: 19928 VA

L Lighting 908 VA 125.00% 1136 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Phase Balance 93 % A-B 55 % B-C 59 % C-A

Total Amps: 66 A 71 A 37 A

Total Load: 7480 VA 8028 VA 4420 VA

41 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 42

39 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 40

37 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 38

35 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 36

33 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 34

31 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 32

29 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 30

27 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 28

25 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 26

23 PROVISIONED SPACE -- -- -- 0 0 -- -- -- PROVISIONED SPACE 24

21 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 22

19 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 20

17 REC: RTU SERVICE - ROOF R 20 A 1 180 0 1 20 A -- SPARE 18

15 2080 1500 16

13PWR: RTU-1N E 30 A 2

2080 15002 20 A E (LCK)PWR: UNIT HEATER

14

11 REC: TV - BUNK RM 205 R 20 A 1 360 2288 12

9 REC: CONV - RM 200, RM 201 R 20 A 1 720 22882 30 A E REC: DRYER

10

7 REC: CONV - INTERVIEW RM 203 R 20 A 1 720 1920 1 20 A E (G)REC: WASHER 8

5 REC: COMP STATION 3 - RM 202 R 20 A 1 540 1052 1 20 A E; L LTG: RM 200-205,EF-1N 6

3 REC: COMP STATION 2 - RM 202 R 20 A 1 540 900 1 20 A R REC: CONV - RM 204, RM 205 4

1 REC: COMP STATION 1 - RM 202 R 20 A 1 540 720 1 20 A R REC: CONV - INVEST OFFICE R... 2

CKT Circuit Description Load Class Trip PolesA

(VA)B

(VA)C

(VA) Poles Trip Load Class Circuit Description CKT

Enclosure: Type 1

Mounting: Recessed Wires: 4 Bus Rating: 100 A

Supply From: Phases: 3 Mains Type: MLO

Location: Space 27 Volts: 120/208 Wye A.I.C. Rating: 18K

Branch Panel: P1

PNLBD LDP

NA

No

.D

ate

Revis

ion

Project No.

Date

Sheet No.

ww

w.a

rch

ima

ge

s-

stl

.co

m

Lene

xa, K

ansa

s 6

6215

14

20

5 W

. 9

5th

Str

ee

tp

: [

91

3] 3

78

.95

33

KS

Arc

hite

ctu

ral C

orp

ora

tio

n

Arc

him

ag

es,

Inc.

# A

-66

9

E701

K19503

10/01/2019

ELEC

TRIC

AL S

CHED

ULES

KC

K F

IRE

DEP

ARTM

ENT

HQ

REM

OD

EL81

5 N

. 6T

H S

T.

Pro

pose

d:N

o.

Date

Revis

ion