shape memory alloys for seismic retrofitting of social ... · shape memory alloys for seismic...

9
Shape memory alloys for seismic retrofitting of social housing in an integrate perspective Scuderi, G.; Teuffel, P.M. Published in: SMAR 2015 - Third Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Strucutres, 7-9 September 2015, Antalya, Turkey Published: 01/01/2015 Document Version Accepted manuscript including changes made at the peer-review stage Please check the document version of this publication: • A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version and the galley proof are versions of the publication after peer review. • The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication Citation for published version (APA): Scuderi, G., & Teuffel, P. (2015). Shape memory alloys for seismic retrofitting of social housing in an integrate perspective. In SMAR 2015 - Third Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Strucutres, 7-9 September 2015, Antalya, Turkey (pp. 1-8) General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal ? Take down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Download date: 20. Jun. 2018

Upload: vuongnga

Post on 11-May-2018

216 views

Category:

Documents


3 download

TRANSCRIPT

Shape memory alloys for seismic retrofitting of socialhousing in an integrate perspectiveScuderi, G.; Teuffel, P.M.

Published in:SMAR 2015 - Third Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Strucutres, 7-9September 2015, Antalya, Turkey

Published: 01/01/2015

Document VersionAccepted manuscript including changes made at the peer-review stage

Please check the document version of this publication:

• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differencesbetween the submitted version and the official published version of record. People interested in the research are advised to contact theauthor for the final version of the publication, or visit the DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and page numbers.

Link to publication

Citation for published version (APA):Scuderi, G., & Teuffel, P. (2015). Shape memory alloys for seismic retrofitting of social housing in an integrateperspective. In SMAR 2015 - Third Conference on Smart Monitoring, Assessment and Rehabilitation of CivilStrucutres, 7-9 September 2015, Antalya, Turkey (pp. 1-8)

General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright ownersand it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.

• Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal ?

Take down policyIf you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediatelyand investigate your claim.

Download date: 20. Jun. 2018

Shape memory alloys for seismic retrofitting of social housing in an integrate perspective

Giuliana Scuderi1, Patrick Teuffel2

1 University of Trento, Trento, Italy 2 Eindhoven University of technology, Eindhoven, Netherlands

ABSTRACT: Traditional buildings are conceived as a set of different construction layers with

different roles, thus generating complex information to coordinate during rehabilitation and

retrofitting. When architectural features are not a concern, such as in most of the social housing

heritage, a new external envelope can be superimposed to the building in order to solve, with a

single intervention, functional, architectural and, in particular, seismic problems. The new

structure, connected to the existing building with shape memory alloys-based seismic devices,

can prevent collapses and dissipate horizontal loads granting a calibrated operability. This paper

shows the feasibility of the proposal through the numerical results of nonlinear static and

dynamic analyses applied to two structural typologies, namely masonry and concrete frame with

masonry infill, in different seismic zones. Finally, the method is verified for a real case study.

1 INTRODUCTION

The effects of the recent earthquakes in Italy highlighted the necessity to improve the seismic

behaviour of the existing building heritage, through interventions of structural rehabilitation and

retrofitting. In this context, post Second World War social housing buildings, suffering today

also of detrimental aesthetical and functional conditions, represent a wide field of action. The

different construction layers, each with a different role, functional, structural or architectural

(Brand, 1994), generate complexity of management when some intervention is planned.

Therefore, on the wake of Lovell’s studies (2010), this paper presents a strategy that promotes

the integration between performances and building systems, leading to the definition of a

structural envelope, which, through the biomimetic design process of Benyus (2002), was called

“building exoskeleton”. This is an enclosing cage superimposed to the existing construction,

able to answer to many different requirements, structural, functional and architectural.

This study presents the application of shape memory alloys devices as connectors between the

“exoskeleton” and the existing structure, to prevent collapses through the passive dissipation of

horizontal loads, with a calibrated operability in relation to the earthquake intensity.

To evaluate the effectiveness of the proposed method, the results of nonlinear static and

dynamic analysis were developed through the software SAP2000, considering the seismic

response of the buildings before and after the intervention.

2 THE PROPOSAL

The international patent of Balducci (2011) introduced the possibility to use dissipative towers

to mitigate the effects of earthquakes in hospitals and schools. The towers can be strategically

located along the perimeter of the buildings and they present dampers in their base able to

reduce significantly the lateral drifts through passive dissipation of the seismic input. With

respect to the traditional methods, the construction phase of the towers does not interfere with

the functionality of the buildings, reducing all the indirect costs; additionally, maintenance,

inspection and substitution of the dampers result simpler due to their concentrated localization.

The “building exoskeleton” re-elaborates and merges traditional and Balducci’s methods, as

shown in figure 1, providing an integrate solution: the three-dimensional structural envelope,

while improving the seismic behaviour of the structure, offers additional space for services and

functions, increasing the economic value of the building and improving its energy performances

and its architectural characteristics.

Furthermore, the position of the dampers and the effectiveness of the choice, which avoids also

uncertainties connected with an altered behaviour of the panels, is explained in figure 2.

The selection of shape memory alloys for the dampers depends on their intrinsic properties –

recentring and energy dissipation capabilities, excellent corrosion and fatigue resistance, large

elastic strain capacity, hysteretic damping– that have a great potential in retrofitting.

Figure 1. Evolution of the dissipative system

Figure 2. Input energy dissipated by the dampers in different configurations

2.1 Shape memory alloys dissipative devices (SMADs)

The first intervention of rehabilitation using shape memory alloys (SMAs) was projected by

Indirli et al. (2001) for the bell tower of St. Giorgio in Trignano, Italy, after the significant

damages caused by the earthquake of the 1996. Four hybrid prestressed ties, made by steel and

SMAs, were located at the internal corners of the tower to improve its flexural resistance.

Croci (2001) and Castellano et al. (2001), after the earthquake of the 1997, studied a method

based on SMAs to reduce the seismic input on the tympanum of St. Francesco in Assisi, Italy,

connecting the element with the roof through superelastic multi-plateaus SMADs.

Subsequently, the unique intrinsic properties of SMAs led to the creation of damping devices, as

the one projected by Krumme et al. (1995) and shown in figure 3, in which SMA wires work

always in tension, while the input loads can be tensile or compressive.

Dolce and Marnetto (1999), figure 3, created a more complex variation of the precedent device,

consisting of the coupling behaviour of NiTi wires with re-centring capabilities and of steel

elements with energy dissipation properties.

The SMADs used in this research are verified with a numerical study while laboratory tests are

still needed. NiTi wires, wrapped around studs in order to work always in tension, provide

tensile and compressive responses. The device was modelled after the device of Dolce et al.

(2000), with an inner and an outer tube to which studs are connected. The outer studs are able to

displace in both the longitudinal directions, in this way allowing the wires to work always in

pure tension. This device, other than allowing the passive dissipation of the seismic energy, is

projected for stress-induced transformation, thus providing re-centring capabilities at the end of

an earthquake.

A numerical database for the SMADs was developed with three possible options, with same

stiffness and damping properties but different value of precompression displacement (figure 4).

Figure 3. On the left Krumme et al.’s device (1995); on the right Dolce and Marnetto’s device (1999)

Figure 4. Examples of force-displacement diagrams for three typologies of SMADs (respectively 0, 5 and

10 millimetres of initial precompression from the left) modelled in SAP2000 with damper-friction spring

link elements.

3 THE ANALYSES

This study considered two building typologies, due to their diffusion in Europe: the use of the

finite element software SAP2000 required the application of a “frame model” for masonry

buildings and of a “strut model” for the concrete frame with masonry infill.

The seismic behaviour of the buildings was analysed before any intervention and after the

introduction of an “exoskeleton”, a steel frame with parietal cross braces designed to resist to

wind loads and connected to the building with SMADs.

The nonlinear analyses considered three different areas - zone 1, 2 and 3 - within the Italian

territory, characterized by different levels of seismicity: zone 1 corresponds to Brescia

(Brescia), zone 2 to Borgo Tossignano (Bologna) and zone 3 to Aielli (L’Aquila). The

pushover analysis evaluated the capacity of the buildings at the different performance levels,

defined by the Italian code (2008) and the FEMA 356 (2000), applying horizontal loads for two

orthogonal directions, for two load distributions, for positive or negative eccentricity, with eight

combinations for each building in total in each of the three seismic zone. The time history

analysis assessed the interstory drift of a control point in relation to the the Italian code (2008)

using seven spectrum compatible accelerograms generated for each of the three zones with the

software SIMQKE for the performance level of immediate occupancy (IO).

3.1 Masonry buildings

The building modelled for this example has a plan of 10x40 meters and four floors 3 meters

high. The “frame model” used to describe the masonry structure is the SAM method by

Magenes and Calvi (1996), then implemented by Magenes and Della Fontana (1998) and shown

in figure 5. The method proposes the description of the walls through linear elements: in the

finite element program, axial columns represent piers while beams represent spandrels. A rigid

portion individuates the physical intersection between piers and spandrels.

In SAP2000 shear hinges are located considering the minimum value between the three

representative collapse modes respectively for piers – combined compressive and bending and

overturning failure, diagonal shear failure, sliding shear failure – and for spandrels – combined

compressive and bending failure and shear failure.

The results of the nonlinear analyses underlined critic seismic responses and interstory drifts in

the transversal direction (Y axis) in all the three zones, as in figure 5 and 6, requiring a retrofit

intervention with the superimposition of the “exoskeleton” as shown in figure 6.

Figure 5. On the left the SAM model; on the right the result of the pushover analysis in Y direction

Figure 6. On the left the SAP2000 model with “exoskeleton”, on the right the interstory drift for zone 2

and the intervention using three typologies of SMADs from the database (0, 5, 10 mm of precompression)

3.2 Concrete frames with masonry infill

The plan of the building is 10x40 meters with eight floors 3 meters high. The “strut model” is

realized using for each panel two diagonal struts with pure compressive behaviour, connected to

the frame at the joints. The geometrical properties and the behaviour of the struts are defined

following the consideration of Al-Chaar (2002), Panagiotakos and Fardis (1996).

The model required the introduction of different groups of hinges in relation to the collapse

modes for the columns – combined compressive and bending failure and shear failure –, for the

beams – bending failure and shear failure – and for the panel, described with axial hinges.

The pushover and time history analyses underlined the necessity of retrofitting, this for both X

and Y direction, as in figure 7 and 8. Again, the “exoskeleton” is able to reduce the interstory

drift of the building under the restriction imposed by the Italian code (2008) as in figure 8.

Figure 8. Results of the nonlinear analyses for the model before and after the intervention

3.2.1 Real case study

The building chosen as the case study is located in the San Bartolomeo neighbourhood, in the

city of Brescia (Italy) and it has a concrete frame, irregular both in terms of spans and for the

dimension of the columns (figure 9).

Figure 9. Aerial view and plan of the ground floor of the real case study building

The concrete frame presents brick infill of “Trieste” type along the perimeter and around the

staircase. The building, which is almost symmetrical in both directions, is characterized by a

rectangular plan with dimensions 10 meters per 40 meters and four floors 3,1 meters high over a

ground floor of 1 meter for a total elevation of 13,4 meters.

The modelling of the panels in the software SAP2000 is realized with the “strut model” with the

same consideration discussed in the previous paragraph.

Pushover analysis underlined the necessity of an intervention (Figure 10) that was realized

verifying three types of SMADs, namely 0, 5 and 10 mm of precompression. In figure 11 the

hysteretic energy properties of the three SMADs are compared to the modal damping energy

and to the total input energy for one of the accelerograms at the life safety performance level.

The time history analyses verified an interstory drift under the limits imposed by the regulation

but, within this example, the considerations of Morandi et al. (2011) were exploited to achieve a

clearer interpretation of the in-plane behaviour of the single panels, with the introduction of

different performance limits and their relative definitions:

- Operational level is verified when no panel reaches an interstory drift of 0,2%;

- Immediate occupancy level is verified when no panel reaches an interstory drift of 0,3%;

- Life safety level is verified when no panel reaches an interstory drift of 1%.

To evaluate the necessity of the procedure the limits were at first verified for the interstory drifts

of the control points, coincident with the centre of masses of each floor, as in figure 12. In

figure 13 the behaviour of the single panels before and after the intervention with the three

typologies of SMADs are evaluated: the 5mm and 10mm precompressed SMADs allow to

achieve the satisfaction of the three performance levels defined by Morandi et al. (2011).

Figure 10. Result of the push over analyses in the longitudinal direction (X direction)

Figure 11. Evaluation of the hysteretic energy of the SMADs

Figure 12. Control points interstory drift verification following Morandi et al. (2011) limits

Figure 13. In plane behaviour of the panels before and after the intervention with three types of SMADs

4 CONCLUSIONS

The properties of SMAs have been considered for an integrate intervention for social housing heritage, in

particular for applications in seismic passive control providing interesting numerical results. Due to their

re-centring capacity, after earthquakes, the devices can reset the original configuration of structures and

they provide good control of displacements for different solicitations. The design of “exoskeletons”,

providing additional spaces, performances and architectural quality, increases the proposal significance.

On the other hand, the use of shape memory alloys, with their high cost per unit weight, requires further

evaluations in terms of economic convenience. Despite a feasibility study is not available yet, the

outcomes obtained by Dolce and Marnetto (2000) in their study of bracing systems for framed structures

are promising. Using the SMA instead of traditional technologies results indeed in negligible additional

expenses with respect of the cost of the device itself, while providing better seismic performances.

Additionally SMADs requires no maintenance, because of their corrosion and fatigue resistance, and they

can be effective also after several earthquakes. With reference to the mentioned results, it appears that the

realization of an intervention based on the use of SMADs would be more convenient than the application

of a traditional technology, even without considering the additional collateral benefits obtained by the

introduction of a “building exoskeleton”.

5 REFERENCES

Al-Chaar, G., 2002, Evaluating strength and stiffness of unreinforced masonry infill structures, US Army

Corp of Engineers, Engineer Research and Development Center.

Benyus, J. M. 2002. Biomimicry: Innovation Inspired by Nature. New York: William Morrow

Paperbacks.

Brand, H. 1994. How Buildings Learn: What happens after they’re built. New York: Viking Press.

Calderoni, B., Cordasco, E.A., Lenza, P. and Pacella, G., 2011, A simplified theoretical model for the

evaluation of structural behaviour of masonry spandrels, International Journal of Materials and

Structural Integrity, 192-214, 5(3).

Castellano, M., Indirli, M. and Martelli, A., 2001, Progress of application, research and development and

design guidelines for shape memory alloy devices for cultural heritage structures in Italy, Proceedings

of SPIE; Smart Structures and Materials.

Croci, G., 2001, Strengthening of the Basilica of St Francis of Assisi after the September 1997

Earthquake, Structural Engineering International.

Decreto Ministeriale 14/01/2008. 2008. Nuove Norme Tecniche per le Costruzioni. Gazzetta Ufficiale n.

29 del 4 febbraio 2008 - Suppl. Ordinario n. 30. Roma.

Dolce, M. and Marnetto, R., 2000, Seismic devices based on shape memory alloy, MANSIDE Project,

Paper No 2386.

Dolce, M., Cardone, D., and Marnetto, R., 2000, Implementation and Testing of Passive control devices

based on shape memory alloys, Earthquake Engineering and Structural Dynamics, 29, 945‐968.

Dolce, M., Cardone, D. and Marnetto, R., 2001, Implementation and testing of passive control devices

based on shape memory alloys, Earthquake Engineering and Structural Dynamics, 29, 945-968.

Dolce, M. and Cardone, D., 2001, Mechanical behaviour of shape memory alloys for seismic

applications. Austenite NiTi wires subjected to tension, International Journal of Mechanical Science,

43, 2657-2677.

Dolce, M. and Cardone, D., 2006, Theoretical and Experimental Studies for the Application of Shape

Memory Alloys in Civil Engineering, Transaction for the ASME, 128, 302-311.

FEMA 356, ASCE. 2000. Prestandard and Commentary for the Seismic Rehabilitation of Buildings.

Indirli, M., Castellano, M., Clemente, P. and Martelli, A., 2001, Demo-application of shape memory alloy

devices: The rehabilitation of the S. Giorgio Church bell-tower, Proceedings of SPIE; Smart Structures

and Materials.

Krumme, R., Hayes, J. and Sweeney, S., 1995, Structural damping with shape memory alloys: One class

of devices, Proceedings of SPIE, Smart Structures and Materials Conference, Paper No. 2445-21.

Lovell, J. 2010. Building Envelopes: An Integrated Approach. Princeton: Princeton architectural press,

Architecture Briefs series.

Morandi, P., Hak, S. and Magenes, G., 2011, Comportamento sismico delle tamponature in laterizio in

telai in c.a.: definizione dei livelli prestazionali e calibrazione di un modello numerico, Atti del XIV

convegno nazionale ANIDIS.

Magenes, G. and Calvi, G.M., 1996, Prospettive per la calibrazione di metodi semplificati per l’analisi

sismica di pareti murarie, Convegno nazionale: La meccanica delle murature tra teoria e progetto.

Magenes, G and Calvi, G.M., 1997, In-plane seismic response of brick masonry walls, Earthquake

Engineering & Structural Dynamics, 26 (11), 1091–1112.

Magenes, G. and Della Fontana, A., 1998, Simplified non-linear seismic analysis of masonry buildings,

5th International Masonry Conference. Proc. of the British Masonry Society, 8, 190-195.

Panagiotakos, T.B. and Fardis, M.N., 1996, Seismic response of infilled rc frames structures, Proceedings

of 11th World Conference on Earthquake Engineering, Paper No.225.