8
ECONAVI Intelligent Eco Sensors SUNLIGHT DETECTION HUMAN ACTVIW DETECTION t|F r*F *e# 1S {*.p r*,f

Upload: others

Post on 09-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • ECONAVIIntelligent Eco Sensors

    SUNLIGHT DETECTION

    HUMAN ACTVIW DETECTIONt|Fr*F

    *e#1S{*.p

    r*,f

  • Infroducing ECONIAVIECONAVI features intelligent Human Activity Detection and new Sunlight Detection technologies that can sense and reduce wasteby optimising air conditioner operation according to room conditions. With just one touch of a button, you can now enjoy a hrgnermaximum energy saving of up to 35%..

    Senses

    Human Activity DetectionSunlight Detectron

    t-t r-tI trrTi tt {#llFf.rSunny Cloudy/Night

    Self-odjusts

    Soves

    Area Detection

    ENERGYWASTED

    Absence Detection

    Sunlight Detection

    l--t r- IHffiECONAVI detects changes ln sunlightintensity jn the room and judgeswhether it is sunny or cloudy/nighi andreduces the waste of cooling underless sunlight conditions,

    Human Activity Detection

    *JWA$TE

    e$M.ry:::ry:.re]

    Area Detection-

    ECONAVI detects humanmovements and reducesthe waste of cooling theunoccupied area of the room.

    Activity Detection

    ECONAVI detects changesin activity levels and reducesthe waste of cooling withunnecessary power.

    rl

    WASTFFEDUCED

    Absence Detection

    ECONAVI detects humanabsence in the room andreduces the waste of coolingan empty room.

    UP TO

    35-LESS

    ELECTRICIW USAGE

    ECONAVI with intelligenteco sensors now has4 abilities to detect andreduce energy waste. Youcan now enjoy a highermaximum energy savingsof up to 35%..

    rcomparison of l,sHP Inverier modet with ECONAVI dual snsor ON and OFF

    ECONAVI dual strsor ON OLtside temperature | 3S.C/24cJRemote setting temperaturer 23oC with Ftr Sp€d (High)Vertcal Airffow direcUont AL,toHorzontal Airflow directon: ECONAV ModeSetting temperatuE g@ up 2rc n total, 1 oC contrcl ed by EC,ONA\4 acuviry level detrction and another 1 .C @ntrolled bvECONAV ighr.rtef sr' oerefiion

    ECONAVI dual sensor OFF Oltside temrerature : 3S.C/24.CRemote setting temperature: 23.C with Fd Speed (H gh)Vertical Air'flow d @tion: AtltoHonzontal Airflow d@lioni Front

    Iotal power rcnsumption amount tre mmsured for t hour in stable condition. At Pmsodc Amenity R@m (sizetJ6.6m1,Th s ls the malmum energy sving value, trd the effmt diffffi according to conditions in installaiion and usge.

    7

  • $unlight Detection

    ECONAVI is switcied on when it is SUNNY

    F

    Set temDerature remain unchanged. EcoNAV| reduces

    cooling powel by an amount equivalent to increasing theset temperature by I degree Celsius.

    when weather changes from sunny to cloudy/night, ECONAVI detects less sunlight intensity and determines iess coollng power rs

    required. lf cooling power remains the same, energy will be wasted. ECONAVI detects this waste and reduces cooling power by

    an anlount equivalent to increasing the set temperature by 1 degree Celsius

    How Does ECONAVI Sunlight Detection Works?

    -J'20min

    s".r"T!.,;,9 *'=* c;91 "o

    e*iset temperature on remote control display remains unchanged

    Remark:Vtheil ECONAVI s sw lche d o. alLr. f rg c ou!1','./rlight ihe lemileraiur€ wii be rf,3 Ntain-od

    irt iho sei t-.rrp-.reftrre Or'; wfler ile serlsof aleiects a cflarge frotr'srnry io

    clo!d,,'lrghl. t ',,r'ir adtrsl ilre iemP(ralirre accordlngy.

    Shift Speed 0.33deg/ 20min1 Hour-l

    , 119:nd'

    Remark:

    B

    ECONAVI detects less cooling power is required,

  • WA$TTFr:*iJ{i!.n

    I@{s\*

    Humqn Activitv DetectionAreo Detection

    c ...

    if $fi +"ECONAVI detects the changes in human

    movements and adjusts the aidlow

    direction not to cool the unoccupied areaof the room, This reduces energy wasted

    of cooling unoccupied area of the room.

    Absence DetecfionActivity Detection

    fl

    ECONAVI detects the changes in activity

    levels and reduces cooling power by

    an amount equivalerL 1o increasing the

    set temperature by 1 degree Celsius.

    This reduces waste of cooling with

    unnecessary power.

    ECONAVI detecLs human absence in

    the room and reduces cooling power

    by an amounI equivalent to gradually

    increasing the set temperature by2 dcarooq Celsir rs This reduces waste

    of cooling an empty room.

    c

    F- ZU mrn

    :4, wasre- nFnll0{:i-l:iffi sM

    ' .'t_. l'

    Flow Does ECONAVI Hurnon ActlvltV Detection Wcrks?

    ;-*-"r tr

    ltF 20 min * 1r'c

    (

    r"o"nU' ; ll s"rt"rp"ru,ur" 11- CoolloPowerRemark: set temperature on remote control display remains unchanged.

    *H&?JF"

    r-*

  • ECCNAVI Intell igent SensorsECONAVI Intelligent Sensors are able to monitor sunlight intensity,

    human movements, activity levels and human absence to detect

    unconscious waste of energy and automatically adjusts cooling

    power to save energy etficiently with uninterrupted cooling comfort

    and convenience.

    Sunlight Sensor Humon ActivitY Sensor

    Sunlight Intensity

    H igh-precision $ensingAll oktjects emit infrared rays which, although invisible, can be detected as heat by ECONAVI's

    Human Activity Sensor if it is within the detection zone. When an object moves within its

    detection zone, ECONAVI compares the object's temperature with the room temperature to

    determine if it is human, and level of activity based on its movement'

    Detects human movements,

    changes in activitY levels and

    human absence.

    l-'-lffi

    L rtl ffiDetecting Humon Presence

    When there ls no movement for over 20 minutes

    ':jj '?

    : ' .'l '

    " '

    Determining the Level of Humon Activity

    llA highly precise conclusion ls reached through a complex algorithm

    '$1t

    Concl!des Level of Actvty High or Norma

    10

  • D ilf erenti*fr*g *hj**fsECONAVI's sensor technology uses factors such as speed, frequency and temperature of every object to determine if it js humanIlectricai mrt:4l(.rs

    Dif.erelce.-temoeratLres A Diffeferce in temperatures Z+

    Senali in*ei::ts

    raFetE

    tt,

    m

    tra

    +

    l\,4ovem e nt

    Difference in temperatures

    l\4ove m e nt

    Both changes may bedetected, but they are toosmall to have any eflect on

    the sensor.

    From the difference intemperatures and thenature of the object's

    movement, ECONAVI candetermine if it is human*.

    z

    A;'*ili:rg ba{!Difference in temperatures

    l\,4ovement

    aa

    il*v*nru6* ffmmmh$$$tiesHuman Activity Sensor covers a wjder area due to its improved area detectjon function

    I:iL1" i"om is divided into 3 detection areas

    $*r-ismr ffi e?eefi*n $}ni mcrpt*Human Activity Sensor detects human activity level and directs airflow to occupied or high activ1y zoneECONAVI is detecting and functioning.

    l%

    W

    nesensorsalCe€fiFlsashumafs unesitmoveswilhnthedeleclionzoneatspeedsrfararelothrnan!oosstDe

    LED indicators indicating

    t2rn I

    I7m

    t1

    1200

    when detecting any chanqe in movements there w ll be a time de ay befdeen the LED ind cator lightif g up and a change ot airflow d rec|onThis is 10 avoid ove.-sensit ve louver movements wh ch w nol conti bute tc energy sav ngs

  • AUTOCOM FORT Provides ConnfortAUTOCOMFORT is used to provide comfort. High Activity Detection detects when the level of activity increases, and automatically

    increases cooling power by an amount equivalent to decreasing the set temperature bry 1 degree Celsius to improve comfod' This is

    explained in the following scenario:

    How AUTOCOMFORT WorksWhen comfod is your priority and energy-saving is your concern, press the AUTOCON,4FORT button, AUTOCOMFORT senses, self-adjusts and

    saves based on the same 3 key factors. as ECONAVI and looks after your comfort with an additional factor, High Activity Detection.

    1AREA SEARCH

    -LOW ACTIVIry DETECTION

    -ABSENCE DETECTION

    HIGH ACTIVIry DFIECTION

    High Activity Deteciion

    High Activity Detection detects the changes

    in activity levels to adjust the air conditioner's

    temperalure to improve comfort. When the

    level of activity increases, the air conditioner

    automatically increases cooling power by

    an amount equivalent to decreasing the set

    temperature by 1 degree Celsius to improve

    comfort. This is explained in this scenarto:

    FCONAVI

    t,;*.1 | , ,1MODT

    .*. ::a

    Level of activity increased.

    Detects high activitY.

    lncreases cooling Power bY an

    amount equivalent to decreasing the

    set temperature by 1 degree Celsius.

    AUTO

    tz

  • How Does AUTOCOMFORT High Activity Detection works?

    --t--= tr

    llI Cooling

    1"9!!9: s:ll:Tp",91,,1 TT !9:ringPo*"IRemark: Set temperatur€ on remote control display remains unchanged

    Remaik:AUIOCC|VlFORI corsufies more energy during high act v]ty level.

    Tips of hcw to se ect FOONAV| or AUTOCONTFOBI. ECONAVI -- To enjo_v enefgy sav ng exc rslvey.. AUTCCOIVFORT - -6 eficy comfod or energy savlng depeno ng oN situat ons

    tc

    it-@ lAffi qffi s

    I

    'Conditions to change back to set fa spe€di 1 ) Sei temperature is achieved, 2) j O mjnutes after enterino the room.