set data directory so that grasp knows where to look for data -file - set data directory - then...
TRANSCRIPT
Set Data Directory so that Set Data Directory so that GRASP knows where to look for GRASP knows where to look for datadata
-FileFile- Set Data DirectorySet Data Directory
- Then browse to data Then browse to data folderfolder
Use -Use - Foreground:Foreground:& Data Load:& Data Load:
- Only use this tag for loading Only use this tag for loading datadata- Type number on Numor(s) lineType number on Numor(s) line
First part of SANS data treatment –First part of SANS data treatment –
Correct for Detector EfficiencyCorrect for Detector Efficiency
Using a scattering substance that scatters uniformally across Using a scattering substance that scatters uniformally across the detectorthe detector
For this use HFor this use H22OO
Zoom in around beam transmissionZoom in around beam transmissionPress this icon and drag around beamPress this icon and drag around beam
Press Centre CalcPress Centre CalcDefines Beam Centre Defines Beam Centre CoordinatesCoordinates
Press Te CalcPress Te CalcCorrects for absorbanceCorrects for absorbance
Press Ts CalcPress Ts CalcCorrects for absorbanceCorrects for absorbance
Check box to subtract Check box to subtract empty cellempty cell Check box to subtract Check box to subtract
cadmiumcadmium
Mask edge of the Mask edge of the detector and region detector and region behind the beam stopbehind the beam stop
Check box to correct the Check box to correct the datadata
Check box to correct for Check box to correct for solid anglesolid angle
Check box to correct for Check box to correct for instrument setupinstrument setup
Calibrates data to water Calibrates data to water scattering intensityscattering intensity
Check box to correct Check box to correct detector efficiencydetector efficiency
Converts data absolute Converts data absolute unitsunits
Open window for radial Open window for radial regroupingregrouping
Second part of SANS data treatment –Second part of SANS data treatment –
Subtract buffers and correct for absorbance and detector Subtract buffers and correct for absorbance and detector efficiencyefficiency
Calculate beam centre Calculate beam centre for sample datafor sample data
Transmission of bufferTransmission of bufferTransmission of sampleTransmission of sample
Check box to subtract Check box to subtract BufferBuffer Check box to subtract Check box to subtract
cadmiumcadmium
Check box to correct the Check box to correct the datadata