servo valves - university of florida...1 chapter 11 servo valves fluid power circuits and controls,...

41
1 Chapter 11 SERVO VALVES Fluid Power Circuits and Controls, John S.Cundiff, 2001 Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion.

Upload: others

Post on 27-Jan-2021

7 views

Category:

Documents


1 download

TRANSCRIPT

  • 1

    Chapter 11

    SERVO VALVESFluid Power Circuits and Controls, John S.Cundiff, 2001

    Servo valves were developed to facilitate the adjustment of fluid flow based on the changes in the load motion.

  • 2

    Typical Open-Loop System

    Goal is to maintain constant speed as the magnitude of the load changes.

    As load increases

    Torque on hydraulic motor increases, pressure then increases and leakage in the motor increases.

    Pressure increase is immediately “seen” at the pump and where leakage increases and flow decreases for each revolution.

    Increased pressure causes pump input torque to increase, which causes the electric motor to slow down reducing the pump output even more, and thus reduces motor speed even more.

  • 3

    Closed loop system

    Speed feedback signal causes the pump displacement to increase until motor speed equals desired speed.

    Within operating range, a load increase does not reduce motor speed.

    Meter-out circuit.

    When extending, cylinder speed is controlled by flow from rod-end through control valve.

    Pressure drop ∆Pfc, adds to other pressure drop so that the relief valve pressure is:∆Ptot = ∆PDCV + ∆Pcyl + ∆Pfc

  • 4

    Pressure compensation in the flow control valve maintains a constant ∆Pfc ,by adjusting the size of the orifice as flow changes.

    The flow control valve is also temperature compensated, adjusting the orifice based on fluid temperature.

    As load pressure goes up, pump flow decreases due to increased internal leakage.

    Leakage between pressure line and the return line in DCV increases. Pump and valve leakage reduces cylinder speed.

    The DCV and flow control valve can be replaced with a servo valve while keeping the rest of circuit the same except for an added pressure line filter.

  • 5

    Total pressure at the relief valve for a given load with filter is

    ∆Ptot1 = ∆Psv1 + ∆Pcyl1 + ∆Pf

    Assume the corresponding flow across the relief valve is Qr1. If cylinder load increases, pressure drop across cylinder becomes ∆Pcyl2.

    Total pressure at relief valve becomes ∆Ptot2 = ∆Psv1 + ∆Pcyl2 + ∆Pf

    Flow across relief valve increases to Qr2. Thus motor slows down.

    If pressure drop across servo valve changed to

    ∆Ptot2 = ∆Psv2 + ∆Pcyl2 + ∆Pf = ∆Ptot1

  • 6

    Flow across relief valve returns to Qr1, and the speed of cylinder is back to it’s original value.

    In many applications, a servo valve is just a means of programming an orifice in the circuit.

    Programmable Orifice

    Servo valve with line-to-line lap condition.

    Similar to 4-way DCV, the valve has four ports: pressure, return, Port A, and Port B.

    When spool is shifted, two orifices are created.

  • 7

    Flow through the valve to the cylinder is given by the orifice equation,

    Q = CdAo

    Where Q = flow (in3/s)Cd = orifice coefficient Ao = orifice area(in2)

    = fluid density (lbf/in3)

    Ps = supply pressure (psi)PA = Port A pressure (psi)g = gravitational constant

    γ/2g As PP−

    γ

    Flow from the cylinder back through the valve is given by

    Q = CdAo

    Load pressure is defined to be PL = PA - PB

    This follows that PA = PL + PB

    γ/2g RB PP −

  • 8

    Substituting in previous equation, Q = CdAo

    We assume symmetry meaning the orifice on both sides have same properties. Equating the two equations, we get

    =

    γ/2g )( BLS PPP +−

    RB PP −)( BLS PPP +−

    Squaring and subtracting both sides,

    Ps - PL - PR = 2 (PB – PR)

    Substituting back, we get,

    Q = CdAo γ/g RLS PPP −−

  • 9

    Often, the equation is written Q = k

    Where k = CdAo

    If conductor from the servo valve back to the reservoir is properly sized, PR

  • 10

    Typical performance curves reported in a servo valvetechnical specification sheet.

    Four curves are shown – one for each of the 100%, 75%, 50% and 25% open positions.

    Each of these curves is a plot of the previous equation with different k corresponding to given open position. Considering 100% curve, when load pressure is 100% of supply pressure, PL = Ps , flow through the valve is zero.

    Control flow = 100% (Rated Flow), when PL = 0.

  • 11

    Control of Pump Displacement

    A variable displacement pump is more expensive, but has numerous features which are advantageous for the design of fluid power circuit.

    Servo valve can be used to change pump displacement and thus change the actuator speed.

    An open loop system becomes closed loop, by mounting a transducer on the output shaft of gearbox.

    Transducer output voltage corresponds to a given shaft speed, and is compared to a setpointvoltage which corresponds to the desired speed.

    Difference between the two voltages is used to increase (or decrease) pump displacement.

    Pump output is continuously adjusted to maintain constant load speed as the load changes within some range.

  • 12

    Four basic servo systems.Servo Actuators

    Valve motorValve cylinder

    Servo Pump systemsServo pump motorServo pump motor split

    It is recommended to mount the valve directly on the actuator

    Most accurate system is the servo pump-motor

    This configuration avoids a column of compressed fluid in the lines

    Result : It gives higher natural frequency for system.

  • 13

    SERVO VALVE CONSTRUCTION

    A servo valve is a precisely machined spool-type directional control valve with some type of actuator to control the spool position.

    A torque motor can be used with a hydraulic cylinder to move the spool, rather than a solenoid mounted at the end of the spool.

    SERVO VALVE CONSTRUCTIONThree types of servo-valves.

    Single-stage : Torque motor supplies enough torque to shift the spool against the pressure.

    Two-stage: Torque motor shifts the pilot spool (first stage), which directs flow to shift the second stage. The second stage supplies flow to the actuator.

    Three-stage: Pilot stage shifts second stage, which shifts the third stage. Three-stage valves are used for application with high flow and high pressure.

  • 14

    SERVO VALVE CONSTRUCTION

    Torque Motor

    Torque motor consists of an armature, two coils and two pole pieces.

    Coils are wrapped on the armature, and armature is mounted such that the ends are positioned in the center of the air gap between upper and lower pole pieces.

    SERVO VALVE CONSTRUCTION

  • 15

    SERVO VALVE CONSTRUCTIONArmature rotates clockwise or counter-clockwise when current is supplied to the coils, depending on polarity.

    The torque motor armature is mounted on a flexible tube which allows it to rotate until the torque produced by magnetic attraction equals the restraining torque in the flexible tube.

    SERVO VALVE CONSTRUCTIONTorque motor can move the pilot spool directly when it rotates. A rod connects the pilot stage spool to armature.

    When armature rotates, its shifts the pilot stage, which ports fluid to the second stage, causing it to shift.

    Feedback linkage ensures second stage spool always has same relative position as pilot stage. If pilot stage spool shifts 25% to right, second stage spool shifts 25% to left.

  • 16

    SERVO VALVE CONSTRUCTION

    Methods for shifting servo valve spool.

    Torque motor can shift the spool directly or indirectly.

    Three indirect methods for shifting the spool. Single flapper nozzle.Double flapper nozzle.Jet pipe.

    SERVO VALVE CONSTRUCTION

  • 17

    SERVO VALVE CONSTRUCTIONDouble flapper nozzle

    Supply pressure is supplied to points Ps ,where orifices are formed on each side between the flapper and the opposing nozzles.

    If torque motor rotates the flapper clock-wise. Now orifice on left is smaller than that on right.

    Pressure at A will be greater than the pressure at B. This pressure difference shifts the spool to the right.

    SERVO VALVE CONSTRUCTIONJet Pipe

    Design is less sensitive to contamination than the flapper nozzle.

    Nozzle attached to the armature, directs a stream of fluid (pressure Ps) AT TWO RECEIVERS.

    If nozzle is centered, two receivers are hit by similar fluid streams and resultant pressure at end of spool is equal.

  • 18

    SERVO VALVE CONSTRUCTION

    SERVO VALVE CONSTRUCTION

    A rotated armature stream of fluid impinges more directly on one nozzle.

    The resulting pressure imbalance shifts the second stage spool.

    Spool shifts until the spring force produces a torque equal to electromagnetic torque.

  • 19

    SERVO VALVE CONSTRUCTION

    Valve Construction

    Port shape (Fig 11.13)Servo valve bodies are machined with three common port shapes.Refer Fig 11.14 (Effect of port shape on flow).A full annulus port gives the highest flow per unit of spool displacement or, correspondingly, per unit of current input to the torque motor.

    SERVO VALVE CONSTRUCTION

  • 20

    SERVO VALVE CONSTRUCTIONLap Condition (Fig 11.15)

    Lap condition refers to position of the spool lands relative to the openings in the valve body.Most common condition is the line-to-line.Spool is machined very precisely to obtain line-to-line fit with the opening in the valve body. Underlapped valve referred to as open centered valve and overlapped valve as closed center valve.Overlapped valve has a deadband so that the spool must move a certain distance before any flow is delivered to the actuator ports.

    SERVO VALVE CONSTRUCTION

  • 21

    VALVE PERFORMANCERated Flow

    Normally specified as the no-load flow, and is measured with no actuator connected between Ports A and B.

    Flow meter is measured between these ports, and will increase as pressure drop across valve (Ps – PR) increases.

    VALVE PERFORMANCE

    Typical flow vs. pressure drop curves for a “family” of different size valves.

    A manufacturer usually labels their valves based on a 1000 psi pressure drop.

  • 22

    VALVE PERFORMANCE

    Pressure Drop

    Load pressure drop is the differential pressure between Ports A and B.

    PL = PA - PB

    Valve pressure drop is the sum of differential pressures across the control orifices of the valve.

    Pv = Ps – PL - PR

    VALVE PERFORMANCE

    Internal Leakage

    Total Flow from the pressure port to return port with Ports A and B blocked is the internal leakage.

  • 23

    VALVE PERFORMANCEHysteresis is shown in the figure, which was obtained by increasing current to the valve from 0 to + rated current and then returning through 0 to – rated current and back to 0.Typically, hysteresis will be less than 3% of rated current.

    VALVE PERFORMANCEThreshold

    Current that must be applied before a response is detected.

    Good-quality two-stage valves have a threshold less than 0.5% of rated current.

  • 24

    VALVE PERFORMANCE

    Gain

    Defined as G = Output

    Input

    Two gains are defined for servo valves: flow gainpressure gain.

    VALVE PERFORMANCEFlow gain is defined

    Gsvf = Flow / Input Current

    Typical units are in3/s/mA.

    Flow gain is determined by measuring control flow vs. input current and plotting the curve (Fig 11.20)

    Data is collected with no load connected between ports A and B.

  • 25

    VALVE PERFORMANCE

    VALVE PERFORMANCEFlow gain is the slope of the curve.

    Actual performance should fall within +-10% of the linear curve.

    Most of the non-linearity occurs in the null region, defined as +-5% of rated current.

    Flow gain in the null region may range from 50% to 200% of expected gain based on the slope of linear line.

  • 26

    VALVE PERFORMANCESpecial spool cuts are available if performance in the null region is critical.

    Pressure gain is defined as Gsvp = Pressure / Input Current

    units being psi/mA.

    To measure pressure gain, Ports A and B are blocked.

    VALVE PERFORMANCEPressure transducers are mounted in Ports A and B and pressure difference is measured as a function of input current.

    The range of input current to produce a load pressure change from -40% to +40% of supply pressure (Ps) is determined.

    Pressure gain is then Gsvp = 0.8 Ps / Input Current

  • 27

    VALVE PERFORMANCE

    Pressure gain is a difficult measurement to make.

    A normal range of pressure gain measurements will be 30 to 100% of Ps for an input current equal to 1% of rated current.

    VALVE PERFORMANCEFrequency Response

    Relates to the ability of servo system to respond to change in the input voltage.

  • 28

    VALVE PERFORMANCE

    •Step input current is applied to the servo valve, and the spool position is plotted versus the time.

    •15 ms open•10 ms return

    VALVE PERFORMANCETotal time for one complete cycle is

    15 ms + 10 ms = 25 ms

    Frequency is 1 cycle x 1000 ms = 40 cycles/s = 40 Hz25 ms s

    If the current is cycled faster than 40 Hz, the valve will not open fully before it begins to close.

  • 29

    VALVE PERFORMANCERatio of output to input is reported in decibels:

    dB = 20 log10 (output/input)

    Suppose the output is 50% of the input.dB = 20 log10 (50/100) = 20 (-0.3)

    = - 6

    VALVE PERFORMANCE•Several excitation signalsused to determine frequency response

  • 30

    VALVE PERFORMANCE•Measured frequency responsefor three different size valvesexcited with +/-140% rated current

    VALVE PERFORMANCEWith +/-100% excitation,

    a resonant phenomenon develops, output is greater than input for frequencies between 40 and 70 Hz. Both excitation shown as attenuation of o/p at higher frequencies. Valve simply cannot move fast enough to track i/p signal.Larger valves have lower frequency response.

  • 31

    VALVE PERFORMANCEPhase Lag

    Phase lag is number of degrees that output lags behind input. (Fig 11.26)

    Output is 30o behind input, so phase lag is defined to be 30o.

    Phase lag is plotted on frequency response curves.

    Frequency at the phase lag 90o means that the valve is beginning to open when the input signal is just beginning to cycle in opposite direction.

    VALVE PERFORMANCE

  • 32

    Types of Servo SystemsServo systems can be used to control position (linear or angular).

    Hydromechanical Servo System

    On large machinery, force required to shift transmissions and perform other control functions can be substantial.

    Ease of operation can give an increase in operator productivity.

    Types of Servo SystemsSystem is hydromechanicalservo.

    Mechanical input moves the servo cylinder to new position.

    Input shifts the spool causing the cylinder to move until valve body aligns with the new spool position.

    Valve body and cylinder body are one piece.

  • 33

    Types of Servo Systems

    Electrohydraulic Servo Systems

    Additional flexibility and versatility can be obtained by using an electric input rather than a mechanical input.

    Types of Servo SystemsPot-Pot Servo

    Command and feedback signals are obtained from potentiometers.

    Command voltage is obtained by rotating the command potentiometer.

    Command voltage is compared with a voltage obtained from potentiometer mounted adjacent to the work table, known as feedback potentiometer.

  • 34

    Types of Servo SystemsDifference between the command and feedback voltages is the “error” voltage, and this voltage is the input to an amplifier.

    The amplifier produces a milliamp current proportional to error voltage. This is the input current to the servo valve torque motor.

    Servo valve opens to direct fluid to cylinder which moves the worktable. Table moves the wiper on feedback pot until feedback voltage = command voltage.

    Types of Servo SystemsForce, Pressure and Torque Servos

    A force servo uses a force transducer as feedback signal.

    A pressure servo uses a pressure transducer

    Torque servo uses a torque transducer.

  • 35

    Types of Servo SystemsForce Servo

    A force transducer is mounted between cylinder and the load. Cylinder increases the force on the load until the transducer output voltage equals command voltage. System then hold this force until command signal is changed.

    Types of Servo SystemsVelocity Servos

    Velocity servos are used to control both linear and rotational velocity.

    Typical velocity servo shown in Fig 11.31

  • 36

    Types of Servo Systems

    Difference between velocity servo and positional servo

    Amplifier output is not 0 for 0 voltage

    If it were 0, servo valve would be closed and no fluid would flow to the motor to produce rotational velocity.

    Types of Servo SystemsServo amplifier for a velocity servo is an integrating amplifier.

    Output of an integrating amplifier ramps up when a positive voltage is applied to the input and ramps down when a negative voltage is applied.

  • 37

    Types of Servo SystemsThe non-zero output changes based on the error voltage applied.

    A dc tachometer is widely used as the feedback transducer for a rotary velocity servo, because it’s high end dc output can be directly connected to the servo amplifier without any need for signal conditioning.

    Spring cavity of pilot –operated relief valve is vented through a two-position, two-way DCV.

    Types of Servo SystemsWhen this line is blocked the relief valve is set at the pilot-setting.

    When it is open, the pump unloads at low pressure.

    Pressure line filter protects the servo valve. Valve is mounted directly on the motor to create valve motor configuration

    Motor speed is controlled by opening servo valve to provide a given pressure drop.

  • 38

    Types of Servo SystemsTotal pressure at relief valve is

    ∆Ptot = ∆Pf + ∆Psv + ∆Pm

    where ∆Pf = pressure drop across filter∆Psv = pressure drop across servo valve∆Pm = pressure drop across the motor

    Relief valve cracks open to divert part of flow back to reservoir, and remaining flow goes to motor.

    Servo AmplifiersA servo amplifier has two main functions.

    It provides a mA current proportional to an input voltage. Typical designs fall in the range 5mA/V to 100 mA/V.

    It saturates at the rated current of the servo valve. The amplifier is designed so that it cannot deliver enough current to the torque motor to burn out coils.

  • 39

    Servo AmplifiersWhy is an amplifier needed for a pot-pot servo system? Why not connect a torque motor between two potentiometers? (Refer Fig 11.32a)

    Suppose command and feedback potentiometers both have a resistance of 40Ω. Analysis shows that current through the coil would be 30 mA per inch of feedback pot movement. If servo valve has a deadband of 5% , and rated current is 30 mA, the deadband is 0.05 x 30 = 1.5 mA. This deadband corresponds to following position error.

    Error = (1.5 mA) / (30 mA/in) = 0.05 in

    Servo Amplifiers

  • 40

    Servo AmplifiersA servo amplifier has a very high input impedance, meaning that almost no current flows into the amplifier at the input.

    This feature allows the use of high–resistance pots and high supply voltage. (Fig 11.32 b)

    If feedback pot travel is 10 in., the feedback transfer function (TF) is 100V / 10 in. = 10V/in.

    Servo AmplifiersSuppose the amplifier gain is 1000 mA/V. Total current is defined by

    G1 = Ga x H Where G1 = total current gain (mA/in)

    Ga = amplifier gain (mA/V)H = feedback gain (V/in)

    In this case , G1 = 1000 x 10 = 10,000 mA/in

    Assuming same servo value deadband, position error is Error = 1.5 ma / (10,000 mA/in) = 0.00015 in

    As compared to 0.05 in. without servo amplifier. So, a servo amplifier provides opportunity to reduce position error.

  • 41

    Chapter 11 (contd.)

    Refer slide Ch 11b