“The Clinical Advantage” A TOMLAB NEW S PUBLISHED BY BIODEX MEDICAL SYSTEMS, INC. • SERVING THE MEDICAL INDUSTRY SINCE 1949 • The optional DICOM interface is completely integrated with the uptake software for seamless operation. Government approved to interface with VistA Imaging. For more information, see inside. B IODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704 Tel: 800-224-6339 (Int’l 631-924-9000), Fax: 631-924-9241 Email: [email protected], www.biodex.com The Atomlab 960 Thyroid Uptake System is an advanced multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. Uptake studies, wipe tests, and other user-defined tasks are accomplished with speed and precision using this fully integrated computer- controlled instrument and its comprehensive selection of application software. The system’s multichannel analyzer has 1024 channels, with individual MCAs for the probe and optional well counter. Engineered for mobility, durability and operational efficiency, the Atomlab 960 handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated. The self-contained Atomlab 960 system is configured on a compact mobile platform with locking casters and a base that measures only 26" w by 34" l (66 x 86.4 cm). An upper shelf supports the flat panel PC with touch-screen display and keyboard. www.biodex.com/thyroiduptake All prices are United States only, international pricing is available upon request.Prices subject to change without notice. Unique Positioning LED for accurate thyroid centering – A first in Thyroid Uptake System design. DICOM Worklist Patient Search Screen

Upload: lekien

Post on 24-Mar-2018

216 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

“The Clinical Advantage”™

ATOMLABNEWSPUBLISHED BY BIODEX MEDICAL SYSTEMS, INC.

• S ERV ING THE MED ICAL INDUSTRY S INCE 1 9 4 9 •

The optional DICOM interface is completely integrated

with the uptake software for seamless operation.

Government approved to interface with VistA Imaging.

For more information, see inside.

BIODEXBiodex Medical Systems, Inc.

20 Ramsey Road, Shirley, New York, 11967-4704 Tel: 800-224-6339 (Int’l 631-924-9000),

Fax: 631-924-9241 Email: [email protected], www.biodex.com

The Atomlab 960 Thyroid Uptake System is an advancedmulti-purpose spectrum analysis instrument designed fordiverse nuclear medicine applications. Uptake studies, wipetests, and other user-defined tasks are accomplished withspeed and precision using this fully integrated computer-controlled instrument and its comprehensive selection ofapplication software.

The system’s multichannel analyzer has 1024 channels, withindividual MCAs for the probe and optional well counter.Engineered for mobility, durability and operationalefficiency, the Atomlab 960 handles clinical tests, safety

compliance tasks, and system administration proceduresquickly and accurately. The system automatically performscalculations, stores patient information and test results, andoutputs clear, concise reports. User-defined uptake protocolscan be initiated.

The self-contained Atomlab 960 system is configured on acompact mobile platform with locking casters and a base thatmeasures only 26" w by 34" l (66 x 86.4 cm). An upper shelfsupports the flat panel PC with touch-screen display andkeyboard.

www.biodex.com/thyroiduptake

All prices are United States only, international pricing is available upon request.Prices subject to change without notice.

Unique Positioning LED foraccurate thyroid centering – A first in Thyroid Uptake System design.

DICOM Worklist Patient Search Screen

Page 2: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

• Unique Positioning LED for accurate thyroid centering

• Distance measurement rod with incremental markings (detector-to-patient)

• All-in-one flat panel PC with solid state hard drive featuring Windows® Operating System

• Count rate: 150,000 cps

• Software programs for Thyroid Uptake, Wipe Test, Quality Assurance, Manual MCA and Bioassay

A complete list of features can be viewed at www.biodex.com/thyroiduptake

Atomlab 960 Thyroid Uptake System

• Supports multiple time-stamped uptakemeasurements

• Auto decay correction

• User-defined uptake protocols

• On-screen spectrum acquisition and analysis

• Reports include normal ranges, notes/comments, facility/physician/technologist

• Automatic daily calibration using Cs-137 source

• Automatic high voltage adjustment

• Automatic Chi-Square test, with report

• Automatic MDA calculation

• Administration summary QA report

• Isotope efficiency calculations

For performing sample counts and analysis beyond the scope ofthe standardized programs.

• Expandable library of 28 commonly used isotopes

• Unlimited user-defined isotopes

• Three counting methods: Preset Time,

Preset ROI, and Continuous Counting

• Meets NRC/State regulations

• Energy spectrums with individual ROIs

• Ability to identify isotopes causing contamination

• User-specific wipe locations and trigger levels

• Wipes that exceed trigger levels are immediately recognized

For individual patients or employee groups.

• For quick and efficient measurement of the staff thyroid burden for I-123, I-125 and I-131.

• Reports can be printed or saved as PDF files.

Thyroid Uptake System, Atomlab 960, 120 VAC, Mobile, PC..................$14,295.00Mobile System includes:• All-in-one flat panel PC with solid state hard drive featuringWindows® embedded standard 7, Atomlab 960 PC software,printer and 1024 channel multi-channel analyzer

• 2" x 2"�tube assembly and base• Mobile support stand with collimator

Export Model Available

Neck Phantom (optional) �

Thyroid Uptake System shownwith Optional Well Counter

Uptake Report Daily Calibration Details Report

Extremely intuitive menus follow conventionally established nuclear medicine procedures. All programs provide clear, concise reports for referring physicians, insurance providers, patient records and a database for physician and technologist identification. PDF reports allow for easy electronic distribution.

Full-size sample reports can be viewed at www.biodex.com/thyroiduptake/reports.

2

Page 3: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

The Atomlab 500 can be used for a wide variety of nuclear medicine, PET andradioimmunotherapy applications, with proven performance for fast, accuratemeasurements. The system consists of a low pressure ionization chamber, electrometerwith extraordinary linearity and an auto-ranging, color touch-screen display.

Activity is displayed on the touch screen in either Curie or Becquerel units.Background correction is performed at the touch of a button. Range selection isautomatic, from .01 microcurie to 100 Curies of Tc-99m or 25 Curies of F-18.

The unit is upgradable at any time to include a wipe test counter.

Standard Apps for Atomlab 500 include:

• Automated Quality Assurance Apps• Constancy and Expanded Constancy• Linearity and Auto Linearity• Accuracy• Geometry

• Nuclear Pharmacy Apps• Future dose and volume computation• Inventory control of 25 samples, correcting volume, activity and moly concentration

• Half-Life Verification • Moly Assay

• Wipe Test Counter Apps• Upgradeable at any time to include a wipe test counter

Dose Calibrator, Atomlab™ 500, 100-240 VAC ........................$6,850.00Includes: Smart Display, ionization chamber, RS-232 port, vial/syringe dipper and well insert.

The Atomlab 500Plus combines the industry gold standard Atomlab 500 DoseCalibrator and Wipe Test Counter, offering you a complete and cost-effective solution forall of your molecular imaging needs. The intuitive Atomlab 500Plus provides fast,accurate radionuclide activity measurements with performance that complies with themost stringent regulatory requirements. It’s comprehensive, easy-to-use and feature rich.

When required, you can be confident that every operation is captured and documented.That documentation makes compliance a breeze. The Atomlab 500 Dose Calibrator isupgradable. You can easily install software updates via the Biodex website or by using aconvenient memory card.

Standard Apps for Atomlab 500 include:

• Automated Quality Assurance Apps• Constancy and Expanded Constancy• Linearity and Auto Linearity• Accuracy• Geometry• Full Width at Half Max (FWHM)• Chi Square• Minimum Detectable Activity (MDA)

• Nuclear Pharmacy Apps• Future dose and volume computation• Inventory control of 25 samples, correcting volume, activity and moly concentration

• Half-Life Verification • Moly Assay

Dose Calibrator, Atomlab™ 500Plus, 100-240 VAC ..............$10,000.00Includes: Smart Display, ionization chamber, wipe test counter, RS-232 port, vial/syringedipper and well insert.

www.biodex.com/dosecalibrators

3

Page 4: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

Linearity tests can be performedusing the traditional manualmethod or with the fully automatedprogram featuring the capability tocapture readings from a source,while automatically recording atspecific intervals. The system willgraph the results. The attenuationtube test for linearity can performedusing software that will guide theuser through the procedure, storesthe values and makes allcalculations.

An Expanded Constancy test allowsthe user to measure a long-livedsource and up to 14 routinely usedisotope settings, all in a matter ofseconds with just one touch of thescreen. The system stores and decaycorrects multiple reference sourcesand compares the measured activityto the calculated activity for thedaily constancy test.

Full size reports can be viewed atwww.biodex.com/dosecalibrators

QA Dose CalibratorScreen – The extensiveselection of qualityassurance applicationsis readily availableand simplifiesregulatory requirements.

Constancy DataScreen – System storesand decay correctsmultiple referencesources, compares themeasured activity to thecalculated activity anddisplays the percentvariance. Data andsource activity plots canbe displayed, printed orstored.

Linearity DecayPlots Screen –Linearity tests can beperformed using thetraditional manualmethod or with thefully automatedprogram featuring thecapability to capturereadings from a source,while automaticallyrecording at specificintervals.

NEW Half-LifeVerification Screen –Results display thecalculated half-life andthe variance to the realhalf-life for the selectedisotope.

Moly Assay ResultsScreen – Applicationsimply guides youthrough the moly assayprocess making it quickand easy to perform,and displays the molyconcentration when testis complete. The systemwill prompt you if theresults are not withinregulatory limits.

Dose CalculationScreen – All theinformation needed todraw doses efficiently isreadily available on onescreen. Easily performspre- and post-decaycalculations, volumecalculations for specifictimes, and changesisotopes all withminimal screen touches.No calculators needed!

• NMIS or BioDose for nuclear medicine department management

• BioRx or RMIS for the nuclear pharmacy

• BioTrax QMS for complete Quality Management for GMP production

www.biodex.com/dosecalibrators

Brett Whittacre,Vice President of ec2Software Solutions, aleading provider ofnuclear medicinemanagementsystems, discussessome of theimportant objectivesof a busy pharmacyand how the

Atomlab Dose Calibrators helphospitals and labs meet their goals.

Brett WhittacreVice President, ec2 SoftwareSolutions

To read Brett’s interview, visitwww.biodex.com/dosecalibrators

4

Page 5: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

edicinex Nuclear MBiode edicine

cleaCENTER

CERESOURedicinex Nuclear MBiode

ce/nuclesourx.com/r.biodewww r 2

edicine

r/16212

“We had doneour homeworkbefore purchasingour Atomlab 960Thyroid UptakeSystem with theoptional DICOMinterface, so we

already knew it was going to do what weneeded,” says Chris Tollefson, RadiologyInformatics Systems Manager at the MayoClinic Foundation in Scottsdale, AZ. “Wedidn’t fully realize until hooking it up andenabling the DICOM functionality, however,that it would save our staff so much timewhile doing even more than we expected.”

Read more

Chris Tollefson B.S., CNMT, NCTMayo Clinic, Radiology Informatics Systems Manager

Scottsdale, AZ

“The New Atomlab 960 Thyroid UptakeSystem is easy-to-use and very intuitive. Thesystem clearly prompts each operation, andthe QC process is quick and simple!

Uptakes on patients can be completedquickly and accurately, and patients seemcomfortable during the procedure. Thesmooth movement of the probe and the newLED marker make patient positioning easyand accurate.”

Peter Cutrera, MBA, CNMTNorthwestern Memorial Hospital

Nuclear Medical TechnologistChicago, IL

Advocate Christ Medical Center Albany Medical CenterBanner Casa Grande Medical CenterBay Area Regional Medical CenterBluffton Medical CampusBrookhaven Memorial HospitalCarle Foundation HospitalCedars Sinai Medical CenterChildren’s Healthcare AtlantaCincinnati Children’s Hospital Medical Center

Delta Medix PCDuke Raleigh HospitalEast Houston Regional Medical CenterElgin Air Force BaseExempla Lutheran Medical CenterForrest General HospitalGuthrie Healthcare SystemHoly Cross HospitalIllinois Valley Community HospitalImperial RadiologyJohn Muir Medical CenterKaiser Permanente – Aurora, COKessler Air Force BaseMadigan Army Healthcare System

Mary Imogene HospitalMayo Clinic – Scottsdale, AZMenorah Medical CenterMethodist Healthcare Olive BranchMethodist Healthcare UniversityMiddle Tennessee State UniversityMiddlesex Memorial HospitalNational Institute of Standards and Technology

Naval Hospital PensacolaNew Orleans East HospitalNorth Kansas City Hospital Ohio State University Hospital EastOverlake Hospital Medical CenterPascack Valley Health SystemProvidence Little Company of Mary Medical Center

Rapid City Regional Hospital Inc.Reading Hospital and Medical CenterReynolds Army Community HospitalRiverside Regional Medical CenterSaint Anthony’s Regional Medical Center

Saint Joseph Hospital and Medical Center

Saint Mary’s Healthcare SystemSaint Vincent’s HealthcareSan Joaquin Community HospitalScott and White Hospital College Station

Sharp Memorial HospitalStanford University Medical CenterStony Brook University HospitalTulsa Cancer InstituteUniversity of AlabamaUniversity of CincinnatiUniversity of KentuckyUniversity of Virginia Medical CenterUtah Valley Regional Medical CenterVA Medical Center – Hampton, VAVA Medical Center – Indianapolis, INVA Medical Center – Pittsburgh, PAVA Medical Center – Poplar Bluff, MOVA Medical Center – Reno, NVWaukesha Memorial HospitalWhite County Cancer CenterWright - Patterson Air Force BaseZwanger and Pesiri

www.biodex.com/thyroiduptake

• Streamlines workflow and improves staff productivity

• Thyroid scans and uptake reports may be displayed simultaneously

• Completely integrated for seamless operation

The optional DICOM Interface integrates the Atomlab 960Thyroid Uptake System with your hospital managementsystem, streamlining workflows and improvingcommunication. The program allows you to retrieve patientinformation from the worklist and upload patient results,without exiting the clinical software, increasing staffproductivity and efficiency. DICOM allows the uptake reportsto be transferred, stored and queried/retrieved throughout afacility. Physicians can view both thyroid scans and uptakereports simultaneously.

The Atomlab 960 has been tested and approved as a DICOM modality to interface with VistA imaging.

DICOM integrates with VistA allowing the thyroid uptake reports to be transferred, stored and queried/retrieved in theVA's electronic health record system as well as exchange medical imagery with the Department of Defense.

5

Page 6: SERVING THE MEDICAL INDUSTRY SINCE 1949 • - · PDF file• SERVING THE MEDICAL INDUSTRY SINCE 1949 ... •Automatic daily calibration using Cs-137 source ... •Expandable library

“The Clinical Advantage”™

ATOMLABNEWSPUBLISHED BY BIODEX MEDICAL SYSTEMS, INC.

• S ERV ING THE MED ICAL INDUSTRY S INCE 1 9 4 9 •

Biodex Medical Systems, Inc.20 Ramsey Road, Shirley, New York, 11967-4704

BIODEXCHANGE SERVICE REQUESTED

BIODEX

• NEWSLETTERS• BLOGS• EMAIL

MADE IN

U . S . A .

Southeastern - October 7-8 • Chattanooga, TN Northeastern Regional - November 4-5 • Stamford, CT

1-800-224-6339Int’l 631-924-9000

www.biodex.comBIODEX