Series 950 Hand Lever P • For transferring

fluid from various tanks and drums.

• Discharge approx. 330mls per stroke.

• 2 inch BSP fitting, anti drip nozzle, telescopic uptake pipe.

• Polypropylene with various seal options, also available in FDA approved food grade.

• Available with many different adapters.

LEVER PUMP MODEL 950 HAND OPERATED

Operating Instructions

Technical Data Lever operated self priming hand pump manufactured from polypropylene with seal options of nitrile, Viton® and EPDM. Will fit directly onto any container with a 2" BSP closure. Can be adapted to suit other closures by using a variety of adaptors that simply screw on. Anti-drip nozzle that can be replaced with a variety of options including positive on/off tap and hose fitment spouts. Pump can be aligned within a full 360° and secured using lock ring. Supplied with a telescopic uptake tube for containers 400 to 915mm deep. Extension uptake tubes can be supplied for deeper containers.

Output Data Delivery when fully primed 330ml per full stroke. 3 full strokes will deliver 1 litre.

fig. 2 Fitting and adjustment of telescopic

Sliding inner uptake tube

Uptake locking sleeve

Pump can be positioned in any orientation of 360° for ideal operating conditions.

Pump Lock ring must be fully tightened to fix pump position and prevent damage to pump during operation.

fig. 3 Alignment and locking of pump prior to operation

fig. 1 Screw lock ring fully onto pump.

1. Screw Lock ring fully onto pump to expose the maximum amount of thread to engage into drum closure. (see fig. 1) 2. Screw telescopic uptake pipe into base of pump and tighten. (see fig. 2) 3. Ensure uptake locking sleeve is not tightened and extend the sliding inner tube to the required length to suit the depth of the container. (see fig. 3) 4. Fully tighten the uptake locking sleeve. (note; if this sleeve is not tightened the pump will draw air through the joint and fail to deliver the full volume of fluid.) (see fig. 2) 5. Screw the pump onto the drum, taking care not to damage the plastic thread. The pump should screw on easily as the fit is designed to be quite loose. Should it be difficult to screw on it is likely that the pump is cross threaded and should be removed and refitted. Do not tighten the pump to the drum - leave the pump easy to rotate. 6. The pump can be rotated fully through 360° to any operating position . 7. Holding the pump body in its desired position screw down the lock ring (turn clockwise) so that it is in tight contact with the drum. This will anchor the pump securely and prevent movement

ERNEST H. HILL LIMITED 10-12 MEADOWBROOK PARK - STATION ROAD - HALFWAY - SHEFFIELD S20 3PJ Telephone ; +44 (0) 114 248 4882 Fax ; +44 (0) 114 248 9142 web site ; http://www.hillpumps.com e-mail ; [email protected]

8. Premature damage to the pump may result if the lock ring is not properly tightened. 9. The pump is operated by raising and lowering the handle. The pump will normally prime and deliver the full volume of fluid after 3 or 4 strokes. For the best performance use a slow rhythmic action. Do not apply sideways forces to the handle whilst pumping as this can cause internal damage to the pump. 10. The pump can be repositioned by first releasing the lock ring and then following steps 6 to 8. 11. To transfer the pump to another container slacken the lock ring (turn counter-clockwise) before unscrewing the pump. If the lock ring is not released first then the thread on the pump body will be damaged. Possible operating Faults Pump does not deliver full volume of fluid

Check outlet spout filter gauze for blockage. Check that telescopic uptake pipe is firmly secured to pump. Check that uptake locking sleeve is fully tightened.

Pump moves or feels insecure whilst pumping

Re-tighten the pump locking ring. Container is flexing and is not suited to this type of pump.

Caution ; This pump is suitable for pumping a very wide variety of fluids. To achieve this range of compatibility requires the appropriate selection of seal material used within the pump. These seal options are nitrile, Viton® or EPDM. Contact your supplier for full compatibility details .

Drawn By Date

Issue Sheet/

ERNEST H. HILL LIMITED

Hill Spec Nitrile Lever PumpP950-AAA

PT 04/12/2002

2 1 1

950 Lever Pump

1 SA0950-200 Nitrile Lever Pump Sub Assy 12 SA0950-203 Outlet Spout Sub Assembly 13 968-10A Nitrile Uptake Pipe 14 950-02 Right Hand Shroud 15 950-03 Left Hand Shroud 16 950-04 Lockring 17 06R08004 Pan Hd Plastite Screw 108 06950-29 "Hill" Handle Label 1

Parts ListITEM DRG No DESCRIPTION QTY

Red ShroudNitrile SealsPack in Standard Carton (06950-32S)Product Code Label "P950-AAA" on Carton

5

7

7

8

7

7

4

6

3

1

2

7

7

7

PACKING INSTRUCTIONSPACK PUMP & UPTAKE IN STANDARD CARTON (06950-32S)UPTAKE ASSEMBLY LABEL ON CARTON

ITEM No DESCRIPTION QTY MATERIALDRG No

1 111

11

PAN HD PLASTITE SCREWOUTLET SPOUT SUB-ASSEMBLYLOCKRING (BLACK)

950/3

R08004950/203950/4

10

POLYPROPYLENE POLYPROPYLENE

MILD STEEL (Z/PLT)SEE BUILD SPEC SA0950-203POLYPROPYLENE

950/212345

SHROUD (GREEN) R.H.SHROUD (GREEN) L.H.

167 RUBBER BAND 1

BUILD SPECIFICATION P950-DVT950 (VITON) LEVER PUMP

ISSUE 2 (17/5/99)

950/201 PUMP SUB-ASSEMBLY (VITON) SEE BUILD SPEC SA0950-201

968/10B UPTAKE PIPE SUB-ASSY (VITON) SEE BUILD SPEC SA0968-S2

PRODUCT CODE LABEL "P950-DVT" ON CARTON

1

6

4

1

2

3 5

7