series 3900 shower assembly - tempered water€¦ · series 3900 shower assembly if the angle stop...

13
DATA SHEET www.lawlervalve.com 5330 East 25th Street Indianapolis, Indiana 46218 Phone (317) 261-1212 Fax (317) 261-1208 Design and specification subject to change without notice. 48 " FLOOR LINE 28 " 1 " 2 N.P.T. HOT INLET N.P.T. COLD INLET 1 " 2 1 3 " 4 3 1" 2 10 1" 2 FINISHED WALL 3" 4 3 6 " OPTIONAL N.P.T. TEMPERED OUTLET 1 " 2 3 " 4 1 DIA. HOLE IN WALL 10" 6 " WARM COLD HOT SHUT N.P.T. TEMPERED OUTLET 1 " 2 ALL PIPING N.P.T. 1 " 2 If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS3 hand spray and DV1 diverter valve. Series 3900 Shower Assembly ENG. NO. 3900-1-A

Upload: others

Post on 23-Sep-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

6 "OPTIONAL

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"6 "

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS3 hand spray and DV1 diverter valve.

Series 3900 Shower AssemblyENG. NO. 3900-1-A

Page 2: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS1 hand spray, DV1 diverter valve and TF2 diverter tub filler.

Series 3900 Shower AssemblyENG. NO.3900-2-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

6 "OPTIONAL

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

6 "

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 3: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks and SH6 shower head.

ENG. NO. 3900-3-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 4: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS3 hand spray, TH5 dial thermometer, DV1 diverter valve and TF2 diverter tub filler.

ENG. NO. 3900-4-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

6 "OPTIONAL

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

6 "

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 5: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange and TH5 dial thermometer.

ENG. NO. 3900-5-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 6: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange and TF2 diverter tub filler.

ENG. NO. 3900-6-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 7: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, TH5 dial thermometer, VC3 concealed volume control and TF2 diverter tub filler.

ENG. NO. 3900-7-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 8: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower AssemblyENG. NO. 3900-8-A

Series 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, VC3 concealed volume control and TF2 diverter tub filler.

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 9: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

Series 3900 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, and VC3 concealed volume control.

ENG. NO. 3900-9-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 10: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

Series 3900 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 thermostatic mixing valve, SC1 straight stop and checks and SH1 shower head, arm and flange.

ENG. NO. 3900-10-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 11: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

Series 3900 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 thermostatic mixing valve, SC1 straight stop and checks and HS3 hand spray.

ENG. NO. 3900-11-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 12: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

ENG. NO. 3900-12-A

Series 3900 thermostatic mixing valve, SC1 straight stop and checks and HS3 hand spray and TF2 diverter tub filler.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

Series 3900 Shower Assembly

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2

Page 13: Series 3900 Shower Assembly - Tempered Water€¦ · Series 3900 Shower Assembly If the angle stop and checks with removable strainers are required, see ENG 3900 A for details. Series

DATA SHEET

www.lawlervalve.com

5330 East 25th StreetIndianapolis, Indiana 46218

Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.

Series 3900 Shower AssemblySeries 3900 thermostatic mixing valve, SC1 straight stop and checks, SH6 institutional shower head, HS1 hand spray and DV1 diverter valve.

If the angle stop and checks with removable strainers are required, see ENG 3900 A for details.

ENG. NO. 3900-13-A

48 "

FLOOR LINE

28 "

1 "2

N.P.T.HOT

INLET

N.P.T.COLDINLET

1 "2

13 "4

3 1"2

101"2

FINISHEDWALL 3"

43

6 "OPTIONAL

N.P.T. TEMPERED OUTLET

1 "2

3 "4

1

DIA.HOLE IN WALL10"6 "

WARM COLD

HOT SHUT

N.P.T.TEMPEREDOUTLET

1 "2

ALL PIPING N.P.T.1 "2