series 008pcqt specification sheet

3
Hood Bonnet O-ring Vent O-ring Body Retainer Check Assembly Series 008PCQT Health Hazard, Anti-Siphon, Spill-Resistant Backflow Preventer  Sizes: 3  ⁄ 8", 1  ⁄ 2", 3  ⁄ 4" and 1" (10, 15, 20, 25mm) Series 008PCQT is designed for indoor point-of-use applica- tions to prevent backsiphonage of contaminated water back into the potable water supply. Separation of the water supply from the air inlet is accomplished by means of a diaphragm seal. This feature protects against any spillage during start-up or operation. Features Standardly supp lied with internal p olymer coating Standardly supplied with T ee handles • Available less T ee handle with stem wrench flats. For use where space is limited • Available in left-handed or right-ha nded outlet Spill-resistant design for ind oor use • Affordable design Modular cartridge for ease of service • Vent uses an O-ri ng for reliable operation Bronze body for durability • Compact space saving design Satin chrome finish available • Available with stra iner Installation  The 008PCQT is designed to be installed at the point of use. When factory installed deck/machine mounted on machines or equipment, the critical level of the 008PCQT shall be not less than 1" (25mm) above the flood rim. If field applied for general plumbing a pplicati ons, the critical level of the 008PCQT shall be a minimum of 6" (150mm) above the flood rim. Specifications  A spill-resistant vacuum br eaker (SVB) shall be installed, in accordanc e with the manufacturer's instructions, as noted on the plans. The valve shall consist of a one-piece modular check and float assembly made of engineered thermoplas tic and housed in a bronze body . Springs shall be stainless steel.  The valve shall be constructed with a molded diap hragm sepa- rating the air inlet from the potable water supply to prevent spillage. The valve shall be a Watts Series 008PCQT.  For Health Hazard and Continuo us Pressure Application s ES-008PCQT Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location –––––––––––––––––––––––––––––––––––––––––  Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contracto r’ s P.O. No. –––––––––––––––––––––––––––––––––––  Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– 008PCQT 008PCQT-L (Left Handed) 008PCQT (Right Handed) FOR INDOOR USE! HoodScrews (2Required) Vent Spring AirBleedScrew BleedO-ring (notshown) TestCock Shutoff ValveAssembly (2Required) Hood Bonnet O-ring Vent O-ring Body Retainer Check Assembly HoodScrew Vent Spring AirBleedScrew BleedO-ring (notshown) TestCock Shutoff ValveAssembly (2Required) Size: 3  ⁄ 8", 1  ⁄ 2" (10, 15mm) Size: 3  ⁄ 4", 1" (20, 25mm) Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts T echnical Servic e. Watts reserves the right to change or modify product design, construction, specifications , or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Upload: watts

Post on 10-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Series 008PCQT Specification Sheet

8/8/2019 Series 008PCQT Specification Sheet

http://slidepdf.com/reader/full/series-008pcqt-specification-sheet 1/2

Hood

Bonnet

O-ring

VentO-ring

Body

Retainer

Check Assembly

Series 008PCQTHealth Hazard, Anti-Siphon,Spill-Resistant Backflow Preventer Sizes: 3 ⁄ 8", 1 ⁄ 2", 3 ⁄ 4" and 1" (10, 15, 20, 25mm)

Series 008PCQT is designed for indoor point-of-use applica-tions to prevent backsiphonage of contaminated water back into the potable water supply. Separation of the water supplyfrom the air inlet is accomplished by means of a diaphragmseal. This feature protects against any spillage during start-up

or operation.

Features

• Standardly supplied with internal polymer coating

• Standardly supplied with Tee handles

• Available less Tee handle with stem wrench flats. For usewhere space is limited

• Available in left-handed or right-handed outlet

• Spill-resistant design for indoor use

• Affordable design

• Modular cartridge for ease of service

• Vent uses an O-ring for reliable operation

• Bronze body for durability• Compact space saving design

• Satin chrome finish available

• Available with strainer

Installation

 The 008PCQT is designed to be installed at the point of use.When factory installed deck/machine mounted on machines orequipment, the critical level of the 008PCQT shall be not lessthan 1" (25mm) above the flood rim. If field applied for generalplumbing applications, the critical level of the 008PCQT shallbe a minimum of 6" (150mm) above the flood rim.

Specifications

 A spill-resistant vacuum breaker (SVB) shall be installed, inaccordance with the manufacturer's instructions, as noted onthe plans. The valve shall consist of a one-piece modularcheck and float assembly made of engineered thermoplasticand housed in a bronze body. Springs shall be stainless steel.

 The valve shall be constructed with a molded diaphragm sepa-rating the air inlet from the potable water supply to preventspillage. The valve shall be a Watts Series 008PCQT.

 For Health Hazard and Continuous Pressure Applications

ES-008PCQT

Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––  Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

 Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––

008PCQT

008PCQT-L (Left Handed)

008PCQT (Right Handed)

FOR INDOOR USE!

HoodScrews(2Required)

VentSpring AirBleedScrew

BleedO-ring(notshown)

TestCock 

ShutoffValveAssembly(2Required)

Hood

Bonnet

O-ring

VentO-ring

Body

Retainer

Check Assembly

HoodScrew

VentSpring AirBleedScrew

BleedO-ring(notshown)

TestCock 

ShutoffValveAssembly(2Required)

Size: 3 ⁄ 8", 1 ⁄ 2" (10, 15mm)

Size: 3 ⁄ 4", 1" (20, 25mm)

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,

please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-

out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Page 2: Series 008PCQT Specification Sheet

8/8/2019 Series 008PCQT Specification Sheet

http://slidepdf.com/reader/full/series-008pcqt-specification-sheet 2/2

Materials

Springs: Stainless steel

Bonnet: PPO

 Vent Disc: EPDM

Disc Holder: PPO

Check Disc: Silicone rubber

Body: Bronze

Pressure – Temperature

 Temperature Range: 33°F – 180°F (0.5°C – 83°C)Maximum Working Pressure: 150psi (10.3 bar)

End Connections

Female NPT - Ball Valve shutoffs

Capacity

 As compiled from documented Foundation for Cross-ConnectionControl and Hydraulic Research at the University of SouthernCalifornia lab tests.

*Typical maximum system flow rate (7.5 feet/sec.)

Note: A strainer is recommended to be installed ahead of the backflow preventer to prevent the fouling of the check 

assembly and resulting spillage from the valve during repressurization. Do not install in concealed locations or areas where

water leakage due to normal wear of the internal parts can cause damage.

008PCQT

SIzE(DN) DIMENSIONS WEIgHT

B D E

in. mm in. mm in. mm in. mm lbs. kgs.

3  ⁄  8 10 51  ⁄  2 140 315  ⁄  16 100 31  ⁄  8 79 1.6 .731

  ⁄  2 15 5

3

  ⁄  4 146 4

3

  ⁄  16 106 3

3

  ⁄  8 86 1.7 .773  ⁄  4 20 7 178 45  ⁄  8 117 41  ⁄  2 114 3.8 1.72

1 25 71  ⁄  2 191 51  ⁄  8 130 47  ⁄  8 124 4.8 2.18

008PCQT-S Bs

3  ⁄  8 10 77  ⁄  8 200 315  ⁄  16 100 31  ⁄  8 79 3.4 1.541  ⁄  2 15 81  ⁄  2 216 43  ⁄  16 106 33  ⁄  8 86 3.5 1.593  ⁄  4 20 101  ⁄  4 260 45  ⁄  8 117 41  ⁄  2 114 5.6 2.54

1 25 113  ⁄  16 284 51  ⁄  8 130 47  ⁄  8 124 7.6 3.45

Standards

Meets requirements of IAPMO.

 Approvals

Listed by IAPMO, Approved by the Foundation for Cross-Connection Control & Hydraulic Research at USC.

D

E

2"

B

Bs

kPa psi

69 10

55 8

41 6

28 4

14 2

0 0

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 gpm0 1.9 3.8 5.7 7.6 9.5 11.4 13.3 15.2   17.1 19 21 lpm

3 ⁄ 8"(10mm)

∆P

FLOW

1 ⁄ 2"(15mm)kPa psi

97 14

83 12

69 10

55 8

41 6

28 4

14 2

0 0

0 1 2 3 4 5 6 7 8 9 10 gpm0 3.8 7.6 11.4 15.2 19 22.8 27 30 34 38 lpm

7.5 fps2.3 mps

*

∆P

FLOW

2",21 ⁄ 2",3"288A

3 ⁄ 4"(20mm)

0 5 1 0 15 20 25 30 35 40 45 50 gpm0 19 38 57 76 95 114 135 152 171 190 lpm

7.5 fps2.3 mps

kPapsi

69 10

55 8

41 6

28 4

14 2

0 0

*

kPapsi69 10

55 8

41 6

28 4

14 2

0 0

*

0 5 10 15 20 25 30 gpm0 19 38 57 76 95 114 lpm

7.5 fps2.3 mps

1"(25mm)

∆P

FLOW

∆P

FLOW

Dimensions — Weights

3 ⁄ 4"(20mm)HoseAdapterwithstrainerwasher

SupplyHose

Shutoff

Testcock 

DispensingInducers

SolenoidValves008PCQT-S WattsP60-M1PressureReducingValve

Typical Installation

1056 B64.1.2

1"min.(25mm)

ES-008PCQT 1118 © 2011 Watts

USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

 A Watts Water Technologies Company