SENSORS
HR100 CT ACTIVE IR MOTION AND PRESENCE SENSORIDENT: 0003463
2 I SENSORS, MODE SELECTORS, ACCESSORIES
Technical specification
HR100-CT Dual Output Pedestrian Door Activation + Monitored SafetyActive Infrared Detection
2000mm to 3000mm (6.5ft to 10ft)230mm (W), 70mm (H), 44mm (D)
Width Adjustment: Inner 3 rows Wide or NarrowWidth Adjustment: Outer 2 rows Wide or Narrow
Depth Adjustment: Inner 3 rows 0° - 8°Depth Adjustment: Outer 2 rows 0° -10°
Depth Adjustment: 1 to 5 rows of detection (Dip Switch)2sec, 30sec, 1min and infinity (Inner 3 rows)
1sec (Outer 2 rows)54
12 to 24V AC or DC +/- 10% AC12V-2.1 [VA] (Max), DC12V-110 [mA] (Max)
AC24V-2.1 [VA] (Max), DC24V-60 [mA] (Max) Open Collector 7.5 [mA] (Min) Resistor Load
Approx. 0.5 secPower On = GreenDetecting = RedDetecting Door = Orange
Power Consumption
OutputRelay Hold Time
-20°C to +60°C, (-4°F to 140°F)Operating Temperature250g (0.55 lbs)
Black: Product Code = HR100-CT/BLSilver: Product Code = HR100-CT/S
2.5m Connection Cable, Mounting Template, Mounting Screws,Installation Instructions
Model
Pattern Adjustment
Presence Timer
IP RaitingPower Supply
Sensors Dimensions
LED Indication
Installation HeightDetection Method
WeightAvailable Colours
Accessories Provided
ON COVERIDENT: 0003444
IN COVERIDENT: 0003385
IN CEILINGIDENT: 0003385
Installation options:
SAFETY FIELD
ACTIVATION FIELD
SENSORS
SSR-3P FOR ESCAPE ROUTES & EMERGENCY EXITSCOMBINED MICROWAVE MOTION AND IR PRESENCE SENSORIDENT: 0003640
3 I SENSORS, MODE SELECTORS, ACCESSORIES
Technical specification
SSR-33.2[m] (10.5[ft]) Max
AC/DC 12 to 24 [V] +/- 10% 50/60HzOpen collector: 7.5 [mA] (Max) Resistor Load
Opto coupler (NPN)Voltage: 55 [VDC] Max. Current : 50 [mA] Max.Dark Current: 100 [nA] Max. (Resistance load)
RADAR: Form A Relay DC50 [V] 0.1[A] Resistor Load6 [mA] Max. @ 24 [VDC]
IP542, performance level D according to EN ISO 13849-1:2008
Cable , Mounting Screw 2pcs.,Mounting Template, Installation Instruction
0.56 [lb.] (0.26 [kg])Black, Silver
Accessories
WeightColor
Model Name
Output
Test Input
IP RateCategory
Supply VoltageInstallation Height
Operating Temperature -20 to +60 [Deg.C],(-4 to 140 Deg.F)Operating humidity Below 80%
ON COVERIDENT: 0003639
IN COVERIDENT: 0003385
Installation options:
ACTIVATION FIELD
SAFETY FIELD
HR94D1-C1ACTIVE IR PRESENCE SENSORIDENT: 0003643
4 I SENSORS, MODE SELECTORS, ACCESSORIES
SENSORS
SIDE SAFETY
Technical specification
HR94D1-C1 Monitored Pedestrian Door Safety Active Infrared Detection
Max 3000mm (10ft) 210mm (W), 65mm (H), 30mm (D)
Width Adjustment: Wide or Narrow (Dials)Depth Adjustment: Body Angle Adjustment 0° - 5° in 3 steps
2, 15, 60 & 180 seconds54
12 to 32V AC or DC AC12V-1.8 [VA] (Max), DC12V-100 [mA] (Max)
AC24V-2.8 [VA] (Max), DC24V-60 [mA] (Max)Open Collector 7.5 [mA] (Min) Resistor Load
Approx. 0.5 secPower On = GreenDetecting = RedDetecting Door = Orange
Self Diagnostics = Red/Green FLASHNIG
Power Consumption
OutputRelay Hold Time
-20°C to +60°C, (-4°F to 140°F)Operating Temperature190g (0.42 lbs)
Black: Product Code = HR94D1-C1/BLSilver: Product Code = HR94D1-C1/S
2.5m Connection Cable, Mounting Template, Mounting Screws,Installation Instructions
Pattern Adjustment
Presence TimerIP RaitingPower Supply
Sensors Dimensions
LED Indication
Installation HeightDetection Method
WeightAvailable Colours
Accessories Provided
Model
ON COVERIDENT: 0003444
IN COVERIDENT: 0003385
Installation options:
SAFETY FIELD
SAFETY FIELDMAIN CLOSING SAFETY
Application options:
MODE SELECTORS
COM20ADVANCED MODE SELECTORIDENT: 800000784
COM21BASIC MODE SELECTORIDENT: 800000786
TOUCH SCREEN GRAPHIC MODE SELECTORSfor advanced users as well as installation,
service and maintenance personnel.
MODE SELECTOR for simple use.
5 I SENSORS, MODE SELECTORS, ACCESSORIES
Dimensions 80x80x19mm( l x w x h )
Dimensions 80x80x19mm( l x w x h )
SWITCHES
6 I SENSORS, MODE SELECTORS, ACCESSORIES
SENSE SWITCHTOUCHLESS OPENINGIDENT: 800000791
Application options:
Touchless opening for hospitals.
SLOW MOTION CLOSING
+IDENT: 0003652IDENT:800000791
=
Dimensions 80x80x19mm( l x w x h )
access control functionality
RFID SWITCHBASIC ACCESS CONTROL IDENT: 800000792
SWITCHES
7 I SENSORS, MODE SELECTORS, ACCESSORIES
Application options:
TAG ACCESS
RFID CARD ACCESS
MOBILE PHONE ACCESS
COMING SOON!
Dimensions 80x80x19mm( l x w x h )
SWITCHES
EMERGENCY SWITCHIDENT: 800000790
For use on escape routes, emergency exit, fire doors and
for safety reasons.
8 I SENSORS, MODE SELECTORS, ACCESSORIES
EMERGENCY OPEN For doors on escape routes & emer-gency exits WITHOUT fire resistance and/or smoke control
Application options:
EMERGENCY CLOSE For doors on escape routes & emer-gency exits WITH fire resistance and/or smoke control
EMERGENCY STOP For standard doors
Dimensions 80x80x19mm( l x w x h )
ACCESSORIES
TANGO 2SW2-CHANNEL WIRELESS TRANSMITTERIDENT: 0000553
CHARACTERISTICS
Power supply/battery typeAbsorbed current in transmittingTransmitting frequencyRadiated powerNumber of combinationsNumber of functionsWorking temperature
9 I SENSORS, MODE SELECTORS, ACCESSORIES
12V/GP23A10 mA
433,92MHz1000 uW
10242
-20 + 55°C
TANGO RB22-CHANNEL WIRELESS RECEIVERIDENT: 0000551
CHARACTERISTICS
Power supplyConsumption in Stand byRelay contact max capacityRelay contact max voltageNumber of outputsCode storageCode storage with MEM16
12/24 Vac/dc40 mA
0,5A30 Vdc
22244
1012
ACCESSORIES
10 I SENSORS, MODE SELECTORS, ACCESSORIES
OT-2S(E)TOUCH OPENING SWITCHIDENT: 0000470
CHARACTERISTICS
HousingDimensions
PVC and aluminium
49x10x187mmm( l x w x h )
LOKUSADVANCED ACCESS CONTROLIDENT: 0001309
Access control for time and attendance control system.
SE 1FIRST OPENING SWITCHIDENT: 800000579
SE 2BUILD-IN WALL FIRST OPENING SWITCHIDENT: 800000580
11 I SENSORS, MODE SELECTORS, ACCESSORIES
ACCESSORIES
CHARACTERISTICS
HousingFrontal plateDimensions
aluminiumaluminium A0
75 x 65 x 75mm(l x w x h)
CHARACTERISTICS
HousingFrontal plateDimensions of frontal plate
aluminiumaluminium A0
75 x 65 x 75mm(l x w x h)
90 x92mm (l x h)
SH 3HANDLE FOR UNLOCKING DOOR IN CASE OF FAILUREIDENT: 800000549
12 I SENSORS, MODE SELECTORS, ACCESSORIES
ACCESSORIES
CHARACTERISTICS
The handle for unlocking door is used only in case of a power cut,
or if the system malfunctions. To unlock the door, the handle
must be stretched out (see Fig. 2).If the system operates normally, the
handle must be pushed down (see Fig. 1).
Fig. 1 Fig. 2
MOD11-AFUNCTION MODULEIDENT: 800000793
MOD11-BFUNCTION MODULE IDENT: 800000794
13 | SENSORS, MODE SELECTORS, ACCESSORIES
ACCESSORIES
Functionality:
- SIDE SAFETY SENSORS - 12V 1A POWER SUPPLY - INPUT - AIR CURTAIN CONTROL - DOOR STATUS OUTPUT - COMMUNICATION EXPANSION
AIR CURTAIN CONTROL APPLICATION
Functionality:
- SIDE SAFETY SENSORS - 12V 1A POWER SUPPLY
ETHERNET MODULE
14 | SENSORS, MODE SELECTORS, ACCESSORIES
ACCESSORIES
BLUETOOTH MODULE
WIFI MODULE
COMING SOON!
COMING SOON!
COMING SOON!
16 | SENSORS, MODE SELECTORS, ACCESSORIES
SENSOR SELECTION
DRIVE OPTION ITEM MOUNTINGlite standard redundant fire mark name interior exterior
1 1 1 SSR-3P activation and safety sensor for emergency exit PL:”D”
X
2 2 2 2 HR100 CT activation and safety sensor X X
3 3 3 HR94D1 C1 safety sensor X3
A A A COM20 advanced mode selector X
B COM21 basic mode selector XB
C SENSE SWITCH touchless opening switch X
D RFID SWITCH basic access control X X
E E E EMERGENCY SWITCH
emergency switch (option: open, close and stop)
X
F SE1, SE2 antiburglary key switch X
G SH3 emergency handle X
H H OT-2S push opening switch X
I LOKUS advanced access control X X