sensitivity analysis of electromechanical impedance responses … · 2017-08-25 · sensitivity...

12
Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete Anchorage Ngoc-Loi Dang 1) , Thanh-Canh Huynh 2) , Joo-Young Ryu 1) and Jeong-Tae Kim 3 * ) 1), 2), 3) Department of Ocean Engineering, Pukyong National University, Busan, Korea *) [email protected] ABSTRACT This study presents a numerical investigation on the sensitivity of electromechanical impedance (EMI) responses to inner cracks of the concrete anchorage caused by overloading. To achieve the objective, the following approaches are implemented. Firstly, the Ottosen failure criterion is selected as a damage model for the simulation of the plasticity in concrete. Secondly, the inner crack formation in the prestressed concrete anchorage is analyzed via finite element (FE) models. Several overloading cases are numerically simulated to induce inside cracks in the FE model of the anchorage. Finally, EMI responses are acquired from the concrete anchorage before and after the inner crack formation. The change in the EMI response due to the formation of inner cracks is then quantified. 1. INTRODUCTION Post-tensioning technique has been widely used in infrastructure construction due to its benefit such as faster installation, improved pure concrete properties, longer span, and effective construction cost. For cable stayed bridges, post-tensioned tendon anchorage systems play an important role in transferring the prestressing force into the main structure. However, during a long-service under environmental effects, repeatedly server loading, or natural disaster, damages may arise in the prestressed concrete anchorage and often cause potential risk on the whole structure (Mehrabi et al. 2010). Damage detection at the anchorage system has receive much attention from researchers (Kim et al. 2004, Ho et al. 2012, Kim et al. 2013, Min et al. 2016). The damages in the tendon anchorage includes prestress-loss in tendon, inner or outer cracks in the concrete, or corrosion in anchor head and bearing plate. Huynh and Kim (2014) developed a mountable PZT interface for prestress force monitoring in the tendon anchorage system. Abdullah et al. (2015) proposed a method to localize and identify damage wire breaks that is based on the strain variations. Min et al. (2016) proposed a methodology to estimate remaining tensile force by using EMI 1) Graduate Student 2) Post-doctoral Fellow 3) Professor

Upload: others

Post on 26-Mar-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete Anchorage

Ngoc-Loi Dang1), Thanh-Canh Huynh2), Joo-Young Ryu1) and Jeong-Tae Kim3*)

1), 2), 3) Department of Ocean Engineering, Pukyong National University, Busan, Korea

*) [email protected]

ABSTRACT

This study presents a numerical investigation on the sensitivity of electromechanical impedance (EMI) responses to inner cracks of the concrete anchorage caused by overloading. To achieve the objective, the following approaches are implemented. Firstly, the Ottosen failure criterion is selected as a damage model for the simulation of the plasticity in concrete. Secondly, the inner crack formation in the prestressed concrete anchorage is analyzed via finite element (FE) models. Several overloading cases are numerically simulated to induce inside cracks in the FE model of the anchorage. Finally, EMI responses are acquired from the concrete anchorage before and after the inner crack formation. The change in the EMI response due to the formation of inner cracks is then quantified. 1. INTRODUCTION

Post-tensioning technique has been widely used in infrastructure construction due to its benefit such as faster installation, improved pure concrete properties, longer span, and effective construction cost. For cable stayed bridges, post-tensioned tendon anchorage systems play an important role in transferring the prestressing force into the main structure. However, during a long-service under environmental effects, repeatedly server loading, or natural disaster, damages may arise in the prestressed concrete anchorage and often cause potential risk on the whole structure (Mehrabi et al. 2010).

Damage detection at the anchorage system has receive much attention from researchers (Kim et al. 2004, Ho et al. 2012, Kim et al. 2013, Min et al. 2016). The damages in the tendon anchorage includes prestress-loss in tendon, inner or outer cracks in the concrete, or corrosion in anchor head and bearing plate. Huynh and Kim (2014) developed a mountable PZT interface for prestress force monitoring in the tendon anchorage system. Abdullah et al. (2015) proposed a method to localize and identify damage wire breaks that is based on the strain variations. Min et al. (2016) proposed a methodology to estimate remaining tensile force by using EMI

1)

Graduate Student 2)

Post-doctoral Fellow 3)

Professor

Page 2: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

characteristics. However, those researches have focused only on the prestress-loss detection in the prestressing tendon. The monitoring of inner cracks in the concrete anchorage is still remained so far.

Impedance-based damage detection has been applied to various types of structures. Yang et al. (2008) implemented the impedance-based method for monitoring damage in concrete structure. Their experimental analysis proved that structural mechanical impedance is sensitive enough to the damage in concrete.

This study presents a numerical investigation on the sensitivity of EMI responses to inner cracks of the concrete anchorage caused by overloading. To achieve the objective, the following approaches are implemented. Firstly, the Ottosen failure criterion is selected as a damage model for the simulation of the plasticity in concrete. Secondly, the inner crack formation in the prestressed concrete anchorage is analyzed via FE models. Several overloading cases are numerically simulated to induce inside cracks in the FE model of the anchorage. Finally, EMI responses are acquired from the concrete anchorage before and after the inner crack formation. The change in the EMI response due to the formation of inner cracks is then quantified.

2. INNER CRACK FORMATION IN PRESTRESSED CONCRETE ANCHORAGE

In this section, the identification of plasticity in reinforced concrete anchorage system due to overloading is investigated by using Ottosen failure criterion. Firstly, Ottosen plasticity model for concrete is visited. Secondly, FE modeling of target anchorage is described. Lastly, the crack formation scenario in anchorage system is analyzed for a few simulated overloading cases.

2.1. Ottosen Plasticity Model for Concrete The Ottosen criterion with a four parameters is a well-known plasticity model for

short-time loading of concrete (Ottosen 1977). The shear failure surface of Ottosen criterion is defined as:

'22 1'

0y c

c

JF A J BI f

f (1)

where A, B, k1, and k2 are dimensionless parameters of concrete; f’c is the uniaxial

compression strength of concrete; the parameter () is defined:

1 2

1 2

1cos cos cos 3 cos3 0

3

1cos cos cos 3 cos3 0

3 3

k a k

k a k

(2)

in which, k1 is called the size factor; k2 also called the shape factor is positive and bounded to 0 ≤ k2 ≤ 1; I1 is the first invariant of stress tensor, J2 is the second invariant

of the deviatoric of stress tensor. The parameter cos(3) relates to the third invariant of the deviatoric stress tensor as presented in Eq (3):

Page 3: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

3

3/2

2

3 3cos 3

2

J

J (3)

The parameters A, B, k1 and k2 can be determined from laboratory testing data:

an uniaxial tensile test, an uniaxial compression test, an equibiaxial compressive stress, and a failure stress state on the compressive meridian. The Ottosen criterion is

equivalent to Drucker-Prager when A=0 and () = constant, or the Von Mises criterion

when A=0, B=0, and () = constant. In this paper, the tensile strength (f’t) of concrete was selected equal 10% of compressive strength (f’c), and four parameters of Ottosen failure criterion for simulating damage in concrete (Ottosen 1977) is listed in Table 1:

Table 1 Typical parameter values for Ottosen failure criterion

' '/t cf f

A B k1 k

2

0.1 1.3 3.2 11.7 0.98

2.2. Finite Element Modelling of Target Anchorage The geometry of target anchorage system referred to a real anchorage design of

Hwamyung Bridge (Busan, Korea), as follows: concrete block 900×900×300 mm, the

bearing plate 400×400×75 mm, the anchor head 280 mm, and 135 mm in height, as shown in Fig. 1a. The target anchorage consists of 31 strands (the typical VLS product). The type of strands is 7-wire super (standard BS5896) with tensile strength of 1860 MPa and specified breaking load of 186 kN per one strand. The boundary condition of the anchorage was simulated as spring elements with the stiffness of kx = ky = 0, and kz

= 2.5×1015 N/m/m2), as shown in Fig. 1b. In the FE model, the anchor head, bearing plate, and concrete block were discrete in 3D solid elements. A number of meshing elements are 2304 elements of anchor head, 3205 elements of bearing plate, and 17290 elements of concrete blocks.

Table 2. Material properties of target anchorage

Parameters Bearing plate and

anchor head Pure

concrete Steel bars

Young’s modulus E (GPa) 200 32 200

Poisson’s ratio, 0.3 0.2 0.3

Mass density, (kg/m3) 7850 2400 7850

Damping loss factor, 0.01 0.01 0.01

Compressive strength f’c, MPa

460 40 460

Tensil strength f’t, MPa 460 4.0 460

Page 4: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

The material properties used in the FE model are presented in Table 2. The compressive strength of concrete without steel bars is 40 MPa. For an anchorage system of cable stayed bridge, the ducts are not grouted, so the tendon is not bonded into concrete. Thus, the tendon was not considered in the FE modelling.

Fig. 1 FE model of target anchorage, a) geometry, b) meshing

To simplify the FE model, the steel bars including vertical and horizontal bars in the anchorage system is converted into equivalent elastic modulus of concrete. An equation based on force equilibrium in concrete and steel bars was presented in Eq. (4).

s s c c eq eqE E E (4)

where s, c, eq are stress in steel bars, concrete, and reinforced concrete of anchorage system, respectively; Es, Ec, Eeq are Young’s modulus of steel bars, concrete and reinforced concrete. To consider all horizontal and vertical steel bars, the Young’s modulus of reinforced concrete was calculated based on volume of each material, as shown in Eq. (5).

s ceq s c

t t

V VE E E

V V (5)

The volume of steel bars is based on a real design of the anchorage. As shown in

Table 3, the Young’s modulus considering contribution of steel bars is 35.65 GPa that increases about 10% modulus of pure concrete.

Anchor head 280

Bearing plate 40040075

Concrete without rebar

Contact springs k

x, k

y and k

z

Prestress force

a) b) Unit: mm

Page 5: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

Table 3. Equivalent elastic modulus of target anchorage

Parameters V (cm3) Parameters E (GPa)

The area of steel bars (Vs)

4,883 Young’s modulus of

steel bars (Es) 200

The area of concrete block without steel (Vc)

218,324 Young’s modulus of pure concrete (Ec)

32

The area of concrete block with steel (Vt)

223,207 Young’s modulus of reinforced concrete

(Eeq) 35.65 Eq. (5)

Next, an equivalent equation to transfer compressive strength of bare concrete to

reinforced concrete (AASHTO, 2007) is shown in Eq. (6).

2

'

1.50.043

eq

c

I

Ef

K

(6)

where KI is the correction factor for the source of aggregate to be taken as 1, is density of reinforced concrete. Substituting the value of each parameter, the equivalent compressive strength considering contribution of steel bars is 49.6 MPa.

To localize plastic areas in concrete, the Ottosen damage model was used for reinforced concrete anchorage. The reinforced concrete of anchorage was simulated by equivalent Young’s modulus and equivalent compressive strength. The material models are defined as elastic-plastic for concrete, anchor head, and bearing plate. When prestress force increased due to overloading, concrete has incipient crack if the stress or strain is greater than the stress or strain from the Ottosen criterion.

Table 4. Simulated cases in FE model of prestressed concrete anchorage

Cases P (kN) Description of crack severity Tensile strength

Intact 3100 Uncrack 0.538fy

Crack level 1

3660 Incipient crack on the surface of bearing plate: 0.10%

volume of simulated concrete anchorage was damaged.

0.635fy

Crack level 2

4380 Incipient cracks inside concrete and expanding

surface crack: 0.43% volume of simulated concrete anchorage was damaged.

0.760fy

Crack level 3

4770 Propagating cracks: 1.52% volume of simulated

concrete anchorage was damaged. 0.827fy

Page 6: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

The prestress force was applied on the surface of anchor head with some damage scenarios due to over loading as presented in Table 4. In intact case, the prestress force in 31-strands was applied 3100 kN equivalent to 100 kN per one strand. The tensile stress of strands is about 54% of maximum tensile strength (fy= 1860 MPa). In crack level 1, when prestress force was increased to 3660 kN, that is equivalent to 63.5% tensile strength of tendon. In this case, an incipient crack was accounted for 0.10% of volume of concrete anchorage. When prestress force increased to 82.7% of limited strength of tendon, the crack is propagated up to 1.52% volume of concrete (crack level 3).

2.3. Analysis of Inner Crack Formation due to Overloading In the intact case, the maximum Von Mises stress found at contact surface

between bearing plate and anchor head is about 280 MPa, as shown Fig. 2. The plasticity in concrete is found if the effective strain is greater than zero. The effective plastic strain of material was calculated and plotted as in Fig. 3. In intact case, there is no plastic area found in anchorage system Fig. 3a.

In the crack level 1, when prestress force was increased to 3660 kN corresponding to 63.5% of tensile strength in tendon, incipient cracks were found at four corners of the bearing plate, as show in Fig. 3b. The plastic area is about 0.10% volume of simulated concrete zone. Due to the small value of tensile strength of concrete and stress concentration at the corners, the surface cracks of concrete were found around the four corners of bearing plate.

In the crack level 2, when prestress force was increased to 4380 kN, the cracks in the concrete surface was expanded and inner cracks were simultaneously formed, as shown in Fig. 3c. There are two types of inner cracks in the anchorage. The first one is crack due to over compressive strength of concrete found under bearing plate. The second one is tensile crack found on the contact surfaces between bearing plate and anchor head.

In the crack level 3, when tensile strength in strands reached to 82.6% of ultimate strength, the cracks in the concrete surface were expanded both on the surface crack and inner crack, as shown in Fig. 3d. The plastic volume in crack level 3 is about 1.52% volume of simulated concrete anchorage.

Fig. 2 Von Mises stress in anchorage system (MPa) for intact case

Page 7: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

Fig. 3 Plasticity distribution in concrete anchorage

3. SENSITIVITY OF IMPEDANCE RESPONSES TO INNER CONCRETE CRACK

In this section, the sensitivity of impedance responses to inner crack of prestressed concrete anchorage is analyzed. The sensitivity of impedance signature is demonstrated via the change of impedance signals before and after damage in host structure. To achieve this aim, firstly, theory of electromechanical impedance is visited. Secondly, the FE modelling of prestressed concrete anchorage with PZT sensor are established corresponding to three crack levels. Lastly, variation of impedance signature is quantified by RMSD and CCD indices, and then analyzed their sensitivity.

3.1. Theory of Electromechanical Impedance The impedance-based method is based on the coupling of mechanical and

electrical characteristics (Liang et al. 1996). A piezoelectric patch can be utilized as sensor and actuator embedded on the surface of host structure. The electrical effects of piezoelectric are partly controlled by mechanical effects of host structure. In practice,

the electric current I() is measured and utilized to calculate EMI (Liang et al. 1994):

1

2

33 3

1 ˆˆ( )( ) ( ) 1

T Ea ax xx

a a s

w lZ i d Y

t Z Z

(7)

a) Intact case b) Crack level 1

Incipient crack

c) Crack level 2

Incipient inner crack

d) Crack level 3

Propagated crack

Page 8: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

where ˆ (1 )E E

xx xxY i Y is the complex Young’s modulus of the PZT patch at zero electric

field; ˆ (1 )T T

xx xxi is the complex dielectric constant at zero stress; d3x is the

piezoelectric coupling constant in x-direction at zero stress; and wa, la, and ta are the

width, length, and thickness of the PZT patch, respectively. The parameters and are structural damping loss factor and dielectric loss factor of piezoelectric material,

respectively. Eq. (7) shows that the EM impedance, Z(), is a combining function of the

SM impedance of the piezoelectric patch, Za(), and that of the host structure, Zs(). The structural impedance of host structure is calculated as follows (Liang et al. 1994).

2 2

( ) nsZ c m i

(8)

where c and m are the damping coefficient and the mass of the structure, respectively;

n, are the angular natural frequency of the structure and the excitation voltage, respectively. The structural mechanical impedance is a function of mass, damping, and stiffness of structural properties. With any change in structural parameters under environmental conditions or damage in structure, it can lead to change in the SM impedance.

The sensitivity of EMI signature to the structural damage can be quantified by the root mean square deviation (RMSD) proposed by as in Eq. (9)

2*

* 1

2

1

Re( ( )) Re( ( ))

,

Re( ( ))

n

i i

i

n

i

i

Z Z

RMSD Z Z

Z

(9)

where Re ( )iZ and Re *( )iZ are the real components of the impedance

signatures measured before and after damage of the ith frequency, respectively, and, n denotes the number of frequency points in the sweep band.

Another statistical index can be also used to measure the sensitivity of impedance signature that is the correlation coefficient deviation (CCD). The CCD is calculated as follows (Zagrai and Giurgiutiu, 2001).

*

* *11 Re( ) Re( ) Re( ) Re( )i i

Z Z

CCD E Z Z Z Z

(10)

where Z and *Z denote the standard deviation of impedance signatures intact case

and damage case respectively; Z and *Z represent the mean value of impedance signatures intact case and damage case respectively.

Page 9: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

3.2. Finite Element Modelling of Prestressed Concrete Anchorage with PZT sensor To analyze the sensitivity of EMI responses to inner cracks of prestressed

concrete anchorage, FE models were established in Comsol Multiphysics with three crack formation scenario in the anchorage. Fig. 4 shows FE model of crack formation in anchorage for crack level 2. The damaged elements were modeled by reducing the Young’s modulus. In this study, Young’s modulus of damaged elements was set as one percent of undamaged one.

The material properties of the anchorage system is listed in Table 2 and Table 3. PZT 5A selected for impedance signature simulation has 20×20×1 mm, detailed information about material properties of PZT 5A can be found at Efunda (2016). Dielectric loss factor of PZT 5A was set 0.015.

Fig. 4 Crack formation in anchorage for crack level 2

In FE modeling of impedance signatures, a PZT sensor was attached on the

surface at the corner of bearing plate as shown in Fig. 5, and the boundary condition of the anchorage was also simulated by the same spring elements with the previous models.

Fig. 5 FE modelling of prestressed tendon anchorage with PZT sensor

Elastic elements (Concrete)

Surface crack Damaged elements

Inner crack

Elastic elements (Steel)

Bearing plate PZT

Contact spring k

x, k

y and k

z

Page 10: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

3.3. Sensitivity of Impedance Responses to Inner Cracks of Concrete Anchorage To simulate impedance signature, a harmonic voltage of 1V was applied on the

top surface of PZT patch while the bottom surface was assigned the ground electrode. The impedance signatures were numerically analyzed in the range 100 kHz to 200 kHz, as shown in Fig. 6. The variation of impedance signatures due to overloading has different amplitude for each crack level.

Fig. 6 Impedance signatures of PZT sensor at the corner on bearing plate

Next, the statistical indices RMSD and CCD were used to quantify the variation of

impedance signatures of sensor under three levels of crack. The damage indices were computed over the range 100 kHz to 200 kHz and shown in Fig. 7a and Fig. 7b. The damage indices go up when the crack severity in the anchorage is increased. Also, the CCD index is found more sensitive than the RMSD for the crack detection.

a) RMSD index b) CCD index

Fig. 7 The RMSD and CCD indices of impedance signatures

100 110 120 130 140 150 160 170 180 190 20018

19

20

21

22

23

24

25

26

27

28

Frequency (kHz)

Re

al Im

pe

da

nce

(O

hm

)

Uncrack

Crack level 1

Crack level 2

Crack level 3

Range 1 Range 2 Range 3 Range 4 Range 5

Intact Crack 1 Crack 2 Crack 30

20

40

60

80

RM

SD

Index (

%)

0.00 1.234.83 6.29

Range: 100-200 kHz

Intact Crack 1 Crack 2 Crack 30

20

40

60

80

CC

D In

de

x (

%)

0.10 0.80

10.9917.49

Range: 100-200 kHz

Page 11: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

Fig. 8 The CCD index of impedance signatures for 20 kHz frequency range

To identify a sensitive range of impedance signatures, the frequency range 100-

200 kHz was split into five narrow ranges of 20 kHz (see Fig. 6). The sensitivity of the 20 kHz frequency ranges was examined under the crack formation in the anchorage, as shown in Fig. 8. The range 2 of 120-140 kHz shows the highest sensitivity while the range 5 of 180-200 kHz has the lowest one. 4. CONCLUSION

This study presented the numerical investigation on the sensitivity of EMI responses to inner cracks of the concrete anchorage caused by overloading. To achieve the objective, the following approaches were implemented. Firstly, the Ottosen failure criterion was selected as a damage model for the simulation of the plasticity in concrete. Secondly, the inner crack formation in the prestressed concrete anchorage was analyzed via FE models. Several overloading cases were numerically simulated to induce inside cracks in the FE model of the anchorage. Finally, EMI responses were acquired from the concrete anchorage before and after the inner crack formation. The change in the EMI response due to the formation of inner cracks was then quantified. ACKNOWLEDGEMENT

This work was supported by Basic Science Research Program of National Research Foundation of Korea (NRF 2016R1A2B4015087). The post-doctoral researcher and graduate students were also supported by the Brain Korea 21 Plus program of Korean Government.

Page 12: Sensitivity Analysis of Electromechanical Impedance Responses … · 2017-08-25 · Sensitivity Analysis of Electromechanical Impedance Responses to Inner Cracks of Prestressed Concrete

REFERENCES

AASHTO (2007) Load and Resistance Factor Design-Bridge Design Specification, 4th edition.

Abdullah, A.B.M., Rice, J.A. and Hamilton, H.R. (2015) "A strain-based wire breakage identification algorithm for unbonded PT tendons", Smart Structures and Systems, 16, No. 3, 415-433.

Cho, K., Cho, J.R., Kim, S.T., Park, S.Y., Kim, Y.J. and Park, Y.H. (2016) "Estimation of prestress force distribution in multi-strand system of prestressed concrete structures using field data measured by electomagnetic sensor", Sensor, 16.

Efunda, I. (2016) http://www.efunda.com, [Online].

Ho, D.D., Kim, J.T., Stubbs, N. and Park, W.S. (2012) "Prestress-force estimation in PSC girder using modal parameters and system identification", Advances in Structural Engineering, 16(6), 997-1012.

Huynh, T.C. and Kim, J.T. (2014) "Impedance-based cable force monitoring in tendon-anchorage using portable PZT-interface technique", Mathematical Problems in Engineering, 2014, 1-11.

Kim, J.T., Huynh, T.C. and Lee, S.Y. (2014) "Wireless structural health monitoring of stay cables under two consecutive typhoons", Structural Monitoring and Maintenance, 1(1), 47-67.

Kim, J.T., Nguyen, K.D. and Huynh, T.C. (2013) "Wireless health monitoring of stay cable using piezoelectric strain response and smart skin technique", Smart Structures and Systems, 12(3-4), 381-379.

Kim, J.T., Yun, C.B., Ryu, Y.S. and Cho, H.M. (2004) "Identification of prestress-loss in PSC beams using modal information", Structural Engineering and Mechanics, 17(3-4), 467-482.

Liang, C., Sun, F.P. and Rogers, C.A. (1994) "Coupled electro-mechanical analysis of adaptive material - Determination of the actuator power consumption and system energy transfer", Journal of Intelligent Material Systems and Structures, 5, 12-20.

Liang, C., Sun, F.P. and Rogers, C.A. (1996) "Electro-mechanical impedance modeling of active material systems", Smart Materials and Structures, 5(2), 171--186.

Mehrabi, B.A., Ligozio, C.A., Ciolko, A.T. and Wyatt, S.T. (2010) "Evaluation, rehabilitation planning, and stay-cable replacement design for the Hale Boggs bridge in Luling, Louisiana", Journal of Bridge Engineering, 15(4), 364-372.

Min, J., Shim, H., Yun, C.B. and J.W, H. (2016) "An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems", Smart Structures and Systems, 17(1), 107-122.

Ottosen, N.S. (1977) "A failure criterion for concrete", Journal of the Engineering Mechanics Division, 103(4), 527-535.

Yang, Y., Hu, Y. and Lu, Y. (2008) "Sensitivity of PZT impedance sensors for damage detection of concrete structures", Sensors, 8, Jan, 327-346.

Zagrai, A.N. and Giurgiutiu, V. (2001) "Electro-mechanical impedance method for crack detection in thin plates", Journal of Intelligent Material Systems and Structures, 12, 709-718.