SEMS is short for Smart Energy Management System The system use PLC or Zigbee technologies to remotely manage and control the
outputs of individual lighting points, and GPRS technology between system Server and Data Concentrators (i.e. a main controller to manage all data and orders between individual lighting points and system Server.).
Each light can be dimmed using automatic profiles to match the specific requirements of the surrounding area throughout the night. At the users command, such as in the event of an emergency, lights can be brought back up to full brightness at the touch of a button, from either a computer, laptop, or smartphone.
Every lighting point within the inventory is remotely monitored, with any faults being reported to the specified user(s) via scheduled email or mobile phone message. Reports in excel or graph formats, detailing the energy usage of each light, or a particular group of lights, are also available.
So far, SEMS has been successfully installed by over 300,000 units across the world and is used to realise significant cost savings and reductions in carbon emissions.
Part I SEMS System Introduction
1. What is SEMS
Road Light Smart Control
Tunnel Light Dimming System
Solar Light Smart Control
Industrial Light Smart Control
Landscape Illumination Smart Control
Part I SEMS System Introduction
2. Application
Remote control individual lamp via computer or smartphone.
Dimming lamps during night. Timing control, Longitude & latitude control. Lamp operation status detection & failure alarm. Remote & local software upgrade Failure notice & map locating function. Electricity data collection, consumption reports, data export
functions.
Part I SEMS System Introduction
3. Functions
4. System Sketch
The system is composed of 3 parts:
• SEMS monitoring software
• Data Concentrator(s)
• Terminal Controller(s)
Part I SEMS System Introduction
4. Benefits of SEMS
Energy Conservation
Adjusting lamps illumination to a configured level at midnight;
30% extra energy saving by dimming function;
Configure illumination levels according to requirements of roads, time, date;
Lengthen lamp lifetime
SEMS Dimming Function
For example : 18:00——19:00 50% Brightnes 19:00——22:00 100% Brightness; 22:00——06:00 50% Brightness
Time 6pm 7pm 8pm 9pm 10pm 11pm 12pm 1am 2am 3am 4am 5am
Brightness 50% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50% 50%
Total Power Consumption 800%
Hour 12
Power Consumption 67%
Energy Saving 33%
Five Function
Easy remote management, control, test, signal communication, dimming, and
inspection;
Cellphone control (GSM mode, use together with GSM modem.)
System Requirements for Cellphone Control
•Android recommended (IOS pending)
•2G sim card recommended
•GSM modem required
Safety Protection
Detect lamp failure/ theft, report alarm, lengthen lamp lifetime 30%.
Report over-load circuit and alarm;
Alarm notice: Server, cellphone message, email.
Wisdom Management
Data collection and create report, analyze data efficiently
Configure illumination levels according to requirements of roads, time, date;
Lengthen lamp lifetime
Quick Maintenance
Detect failure and alarm, no labor cost for touring roads, save maintenance
cost 50%.
Configure illumination levels according to requirements of roads, time, date;
Lengthen lamp lifetime
Part I SEMS System Introduction What is SEMS Application Functions System Sketch Benefits of SEMS
Part II Product Data Concentrator Terminal Controller SEMS Monitoring Software Function Expansion Modules
Part III Project Reference
Content
Data Concentrator plays a key role in structure and adjustment of the communication network for SEMS system.
It receives data from Terminal Controller(s), forward commands to them; and it communicates with Server, receives commands and reports all related data.
Part II Product
1. Data Concentrator
Item No.CC08 Series CC09 Series
CC08 CC08T CC08Z CC09
ApplicationRoad Lighting,
Landscape Illumination, Industrial Lighting
Tunnel Light
Zigbee Control
Lighting
Road Lighting, Landscape Illumination,
Industrial Lighting
Model & Application
1. Data Concentrator
CC08 Functions & Features
1. Data Concentrator
Data collection: Collect data including voltage, current, power, etc. from Terminal Controller(s), support MODBUS protocol.
Communication: Ethernet, GPRS, Zigbee. Adjust lighting schemes automatically, according to longitude &
latitude. Power on/off /dim/query the controllers and have signal relay function. Support magnetic door switch detection. Failure alarm notice function, via MSG, email, Server. Support software update locally or remotely.
Part II Product
2. Terminal Controller
Terminal controllers receive commands from a concentrator to power on/off or dim the lamp.
Terminal controllers can monitor the status of the lamp and transmit the data back to the concentrator.
Remote power on/off the lamp. 0-10V dimming interface Autonomous running function Remote current, voltage, power reading function. Sodium and LED lamp failure detection function. Failure report Lightning protection
RTU09B Functions & Features
2. Terminal Controller
Part II Product
3. SES Monitoring Software
The software runs on host computer, it serves as a platform to control / manage the system, to collect measured data (current, power consumption, alarm, etc.) and monitor the status of the lighting system.
3. SEMS Monitoring Software
Homepage IntroductionA B C D E F G
H
I
J
K L
M
N
A. Application function menu button B. User account management and user log and hardware log management C. Directory configuration/ concentrator configuration/ terminal task setting D. Device deployment on map and device status map query E. Hardware management F. Output consumption report G. Provide help information H. Current main function menu I. Current area information J. Devices directory details under the current area K. Turn on the chosen devices L. Turn off the chosen devices M. Alarm reminding and alarm numbers display N. Work space of the current area
3. SEMS Monitoring Software
Homepage Introduction
3. SEMS Monitoring Software
Basic Task Introduction
1. Lamp on / off
2. Lamp Dimming
3. Lamp Failure Alarm & Notice
4. Power Data Report
5. Asset Report
Anti-Theft Devices•Cable Anti-Theft Module•Cable Anti-Theft Terminal
Use Light Sensor to Drive Lamp On/Off•Photocell Module (One/two pieces for each project)
Collect Current Data from other Ammeter •Current Expansion Module (Built-in power distribution cabinet)
4. Function Expansion Modules (Optional Devices)
Part I SEMS System Introduction What is SEMS Application Functions System Sketch Benefits of SEMS
Part II Product Data Concentrator Terminal Controller SEMS Monitoring Software Function Expansion Modules
Part III Project Reference
Content
Part III Project Reference
City Road Lighting Smart Control
New Energy Street Light Smart Control
Tunnel Lighting Smart Dimming System
Industrial Lighting Smart Control
Landscape Illumination Smart Control
Project Scenarios
City Road Lighting Smart Control
Stuttgart, Germany
200pcs
LED lamps
April 2011
Unilumin provided
City Road Lighting Smart Control
Istanbul, Turkey
2000pcs
LED lamps
May 2013
Client provided
City Road Lighting Smart Control
Tehran, Iran
200pcs
LED lamps
May 2014
Client provided
City Road Lighting Smart Control
Israel
36pcs
LED lamps
Mach 2014
Client provided
City Road Lighting Smart Control
Guangzhou-Shenzhen Highway, China
7000pcs
LED lamps
April 2010
Unilumin provided
City Road Lighting Smart Control
Xiamen, China
2000pcs
HPS lamps
Sep. 2011
Client provided
City Road Lighting Smart Control
Shenyang, China
15000pcs
LED lamps
Jun 2012
Client provided
Tunnel Lighting Smart Dimming System
Gansu, China
1578pcs
LED Tunnel lamps
Mar, 2012
Client provided
Landscape Illumination Smart Control
Jiangxi, China
395pcs
Distribution Box
Sep, 2013
Client provided
SERVICE HOTLINE: 4008-090-880
Website : www.iotcomm.com
SHENZHEN IOTCOMM TECHNOLOGY CO., LTD (Overseas Sales)Add.: 1002#, Chinese Overseas Scholars Venture Building, Hi-tech Area, Nanshan District, Shenzhen, China. Tel : 0755-86329565 Fax : 0755-86329569
XIAMEN IOTCOMM TECHNOLOGY CO., LTD (HQ & Production)Add.: 3F, North Building, N0.1 Cengcuoan North Road, Software Park, Hi-tech Area, Siming District, Xiamen, Fujian State, China. Tel : 0592-2517558 Fax : 0592-2520926