sedarc - hurst-rosche, inc. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @...

10
ALTERNATE BID #1 BASE BID SITE LOCATION DATE: 08-10-2020 AREA LOCATION MAP ARCHITECT / ENGINEER : HR: 150-1600 TOILET RENOVATION DIVERNON TOWNSHIP LIBRARY 221 SOUTH SECOND STREET DIVERNON, SANGAMON COUNTY, ILLINOIS EAST ST. LOUIS, IL MARION, IL ARNOLD, MO NEOSHO, MO NASHVILLE, TN 1400 E. TREMONT STREET HILLSBORO, IL PH: 217.532.3959 Hurst-Rosche, Inc. PROFESSIONAL DESIGN NUMBER: 184-000298 www.hurst-rosche.com SHEET INDEX: G-101 COVER SHEET A-100 ADA GUIDELINES & CODE INFORMATION A-101 FLOOR PLANS, WALL TYPES, DOOR AND ROOM FINISH SCHEDULES A-102 ELEVATIONS AND DETAILS A-103 ALTERNATE BID #1 INFORMATION A-104 STRUCTURAL DETAILS P-101 PLUMBING PLANS M-101 MECHANICAL PLANS E-101 ELECTRICAL PLANS KEYPLAN L I C E N S E D A R C H I T E C T S T A T E O F I L L I N O I S TIMOTHY L DOWNEN 001.021928 EXPIRES: LICENSE DATE: TIMOTHY L. DOWNEN, AIA 11-30-2020 08-10-2020

Upload: others

Post on 10-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

ALTERNATE

BID #1

BASE BID

SITE LOCATION

DATE: 08-10-2020

AREA LOCATION MAP

ARCHITECT / ENGINEER :

HR

: 1

50

-1

60

0

TOILET RENOVATION

DIVERNON TOWNSHIP LIBRARY

221 SOUTH SECOND STREET

DIVERNON, SANGAMON COUNTY, ILLINOIS

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

1400 E. TREMONT STREET

HILLSBORO, IL

PH: 217.532.3959

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

SHEET INDEX:

G-101 COVER SHEET

A-100 ADA GUIDELINES & CODE INFORMATION

A-101 FLOOR PLANS, WALL TYPES, DOOR AND ROOM FINISH SCHEDULES

A-102 ELEVATIONS AND DETAILS

A-103 ALTERNATE BID #1 INFORMATION

A-104 STRUCTURAL DETAILS

P-101 PLUMBING PLANS

M-101 MECHANICAL PLANS

E-101 ELECTRICAL PLANS

KEYPLAN

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

EXPIRES:LICENSE

DATE:

TIMOTHY L. DOWNEN, AIA

11-30-2020

08-10-2020

AutoCAD SHX Text
COOK
AutoCAD SHX Text
DU PAGE
AutoCAD SHX Text
KANE
AutoCAD SHX Text
DE KALB
AutoCAD SHX Text
LEE
AutoCAD SHX Text
WHITESIDE
AutoCAD SHX Text
OGLE
AutoCAD SHX Text
CARROLL
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MC HENRY
AutoCAD SHX Text
BOONE
AutoCAD SHX Text
WINNEBAGO
AutoCAD SHX Text
STEPHENSON
AutoCAD SHX Text
JO DAVIES
AutoCAD SHX Text
PUTNAM
AutoCAD SHX Text
MARSHALL
AutoCAD SHX Text
LIVINGSTON
AutoCAD SHX Text
IROQUOIS
AutoCAD SHX Text
KANKAKEE
AutoCAD SHX Text
WILL
AutoCAD SHX Text
GRUNDY
AutoCAD SHX Text
KENDALL
AutoCAD SHX Text
LASALLE
AutoCAD SHX Text
BUREAU
AutoCAD SHX Text
HENRY
AutoCAD SHX Text
STARK
AutoCAD SHX Text
PEORIA
AutoCAD SHX Text
KNOX
AutoCAD SHX Text
WARREN
AutoCAD SHX Text
HENDERSON
AutoCAD SHX Text
MERCER
AutoCAD SHX Text
ROCK ISLAND
AutoCAD SHX Text
MACON
AutoCAD SHX Text
MOULTRIE
AutoCAD SHX Text
DOUGLAS
AutoCAD SHX Text
COLES
AutoCAD SHX Text
EDGAR
AutoCAD SHX Text
CLARK
AutoCAD SHX Text
CUMBERLAND
AutoCAD SHX Text
SHELBY
AutoCAD SHX Text
CHRISTIAN
AutoCAD SHX Text
MONTGOMERY
AutoCAD SHX Text
MACOUPIN
AutoCAD SHX Text
JERSEY
AutoCAD SHX Text
GREENE
AutoCAD SHX Text
CALHOUN
AutoCAD SHX Text
PIKE
AutoCAD SHX Text
SCOTT
AutoCAD SHX Text
MORGAN
AutoCAD SHX Text
SANGAMON
AutoCAD SHX Text
MENARD
AutoCAD SHX Text
CASS
AutoCAD SHX Text
BROWN
AutoCAD SHX Text
ADAMS
AutoCAD SHX Text
SCHUYLER
AutoCAD SHX Text
MASON
AutoCAD SHX Text
LOGAN
AutoCAD SHX Text
DEWITT
AutoCAD SHX Text
PIATT
AutoCAD SHX Text
VERMILION
AutoCAD SHX Text
CHAMPAIGN
AutoCAD SHX Text
FORD
AutoCAD SHX Text
MCLEAN
AutoCAD SHX Text
WOODFORD
AutoCAD SHX Text
TAZEWELL
AutoCAD SHX Text
FULTON
AutoCAD SHX Text
MC DONOUGH
AutoCAD SHX Text
HANCOCK
AutoCAD SHX Text
WABASH
AutoCAD SHX Text
EDWARDS
AutoCAD SHX Text
GALLATIN
AutoCAD SHX Text
SALINE
AutoCAD SHX Text
WILLIAMSON
AutoCAD SHX Text
JACKSON
AutoCAD SHX Text
RANDOLPH
AutoCAD SHX Text
PERRY
AutoCAD SHX Text
FRANKLIN
AutoCAD SHX Text
HAMILTON
AutoCAD SHX Text
WHITE
AutoCAD SHX Text
WAYNE
AutoCAD SHX Text
JEFFERSON
AutoCAD SHX Text
WASHINGTON
AutoCAD SHX Text
MONROE
AutoCAD SHX Text
ST. CLAIR
AutoCAD SHX Text
CLINTON
AutoCAD SHX Text
MARION
AutoCAD SHX Text
CLAY
AutoCAD SHX Text
RICHLAND
AutoCAD SHX Text
LAWERENCE
AutoCAD SHX Text
CRAWFORD
AutoCAD SHX Text
JASPER
AutoCAD SHX Text
EFFINGHAM
AutoCAD SHX Text
FAYETTE
AutoCAD SHX Text
BOND
AutoCAD SHX Text
MADISON
AutoCAD SHX Text
MASSAC
AutoCAD SHX Text
PULASKI
AutoCAD SHX Text
ALEXANDER
AutoCAD SHX Text
UNION JOHNSON POPE HARDIN
AutoCAD SHX Text
N
AutoCAD SHX Text
N
Page 2: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

16-18

405-455

LC

(a)

wheelchair

accessible

water closets

12 max

42 min

54 min

1370

305

1065

transfer

side

12 min

305

LC24 min

610

36 min

915

15

m

in

380

7-9

180-230

48

m

ax

1220

LC

(b)

stall type

(a)

wall hung type

17 max

430

345

13½ min13½ min

345

10 max

255

1220

48

m

ax

34

m

ax

865

34

m

ax

865

46

m

ax

1170

> 10-24 max

255-610

(a) (b)

10 max

255

1220

48

m

ax

15

m

in

380

48

m

ax

1220

44

m

ax

1120

>20-25 max

510-635

20 max

510

(a) (b)

15

m

in

380

48

m

ax

1220

11 min

27

m

in

685

280

205

8 min

9 min

230

(a)

elevation

(b)

plan

30

m

in

760

635

25 max17-25

9

230

430-635

6 max

150

30

m

in

760

(a)

elevation

(b)

plan

42 min

48

m

in

1220

1065

1220

X < 48

42 min

1065

X < 48

1220

36 min

915

36 min

915

60

m

in

1525

(a)

180 degree turn

(b)

180 degree turn

(Exception)

6 m

in

150

MEN

not in

pictogram

field

18 min

455

18 min

455

45°

centered on

tactile characters

LC

SCALE: N.T.S.

TOE CLEARANCE

SCALE: N.T.S.

KNEE CLEARANCE

SCALE: N.T.S.

UNOBST. FORWARD REACH

SCALE: N.T.S.

OBST. HIGH FORWARD REACH

SCALE: N.T.S.

UNOBST. SIDE REACH

SCALE: N.T.S.

OBST. HIGH SIDE REACH

SCALE: N.T.S.

WATER CLOSET LOCATION

SCALE: N.T.S.

SIDE WALL GRAB BAR

SCALE: N.T.S.

REAR WALL GRAB BAR

SCALE: N.T.S.

DISPENSER OUTLET LOCATION

SCALE: N.T.S.

URINAL HEIGHT / DEPTH

SCALE: N.T.S.

CLEAR WIDTH AT TURNS

ADA GUIDELINES

& CODE

INFORMATION

TLD NAL TLD

A-100

CODES & STANDARDS

INTERNATIONAL BUILDING CODE 2015, EXCLUDING CHAPTER 11

INTERNATIONAL EXISTING BUILDING CODE 2015

INTERNATIONAL FIRE CODE 2015, EXCLUDING CHAPTER 4

INTERNATIONAL FUEL GAS CODE 2015

INTERNATIONAL MECHANICAL CODE 2015

INTERNATIONAL PROPERTY MAINTENANCE CODE 2015

INTERNATIONAL ENERGY CONSERVATION CODE 2015

INTERNATIONAL PLUMBING CODE 2015

NATIONAL ELECTRIC CODE 2014

ILLINOIS PLUMBING CODE (71 ILL. ADM. CODE 890)

ILLINOIS ACCESSIBILITY CODE (71 ILL. ADM. CODE 400)

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

LI

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

SCALE: N.T.S.

SIGNAGE

SCALE: N.T.S.

SIGNAGE PLACEMENT

Page 3: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

2

6

5

1

1

3

4

4

3

1

1

5

6

1/A

-1

02

7'-0"

7'-6

1

/2

"

7

A-104

1&2

A-104

4

1

2

3

102

TOILET

1

6/A

-1

02

4/A-102

5/A

-1

02

2/A

-1

02

102

1

2

7'-1"+/- 4'-0"

7/A-102

A-101

5

8'-0" 6'-4"

6'-6

"9

"7

'-0

1

/2

"

3

3

3

3 3

3

3

3

3

A-104

3

A-104

5

5

4

1

1

2

" GYP. BOARD

2

2X4 WOOD STUDS

@ 16" O.C.

1

2

" GYP. BOARD

2X4 WOOD STUDS

@ 16" O.C.

3

1

2

" GYP. BOARD

2X4 WOOD STUDS

@ 16" O.C.

1

2

" + 2-1/2" THICK CLOSED

CELL POLYURETHANE

SPRAY FOAM

INSULATION (MIN.

R-VALUE OF 6 PER INCH

OF THICKNESS)

EXISTING MASONRY

MIN.

1

2

" AIR GAP

SEALANT - BOTH SIDES

JAMB - HEAD SIM.

2X4 STUDS @ 16" O.C.

2X WOOD TRIM - PRIME

AND PAINT

1X WOOD TRIM - PRIME

AND PAINT

EXISTING BRICK/BLOCK

1X2 WOOD TRIM - PRIME

AND PAINT

A

HEAD

B

JAMB

CAULKING - TYPICAL

DOOR AS SCHEDULED

HOLLOW METAL DOOR

FRAME - FILL W/ FOAM

INSULATION

1

2

" GYP. BOARD

2X4 STUDS @ 16" O.C.

5 3/4"

CAULKING - TYPICAL

DOUBLE 2X4 JAMB

DOOR AS SCHEDULED

HOLLOW METAL DOOR

FRAME - FILL W/ FOAM

INSULATION

1

2

" GYP. BOARD

2X4 STUDS @ 16" O.C.

5 3/4"

1

2

" GYP. BOARD

1

2

" GYP. BOARD

2X4 HEADER W/ SPACER

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, ILLIN

OIS

221 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

LIB

RA

RY

TO

ILE

T R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

FLOOR PLANS, WALL

TYPES, DOOR AND

ROOM FINISH

SCHEDULES

TLD NAL TLD

A-101

GENERAL NOTES:

1. PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTED

OTHERWISE. DO NOT SCALE DRAWINGS - USE DIMENSIONS.

2. PROVIDE & INSTALL BLOCKING BEHIND ALL WALL MOUNTED ITEMS INDICATED IN

DRAWINGS AND SPECIFICATIONS.

3. UNLESS OTHERWISE NOTED OR DIMENSIONED, ALL DOORS SHALL BE INSTALLED

WITH A MINIMUM OF 12” CLEAR SPACE FROM EDGE OF DOOR TO NEAREST WALL OR

OBSTRUCTION ON PUSH SIDE OF DOOR AND WITH A MINIMUM OF 18” CLEAR SPACE

FROM EDGE OF DOOR TO NEAREST WALL OR OBSTRUCTION ON PULL SIDE OF DOOR.

4. UNLESS NOTED OTHERWISE, ALL WALL FRAMING AND SHEATHING IS TO EXTEND TO

BOTTOM CHORD OF TRUSSES.

NORTH

DEMOLITION KEYED NOTES:

1. DEMOLISH EXISTING CEILING, TRIM, AND ALL RELATED ACCESSORIES. SEE OTHER TRADE SHEETS FOR

ADDITIONAL DEMOLITION OF CEILING MOUNTED LIGHTS, DIFFUSERS, ETC.

2. DEMOLISH EXISTING FLOORING AND ALL WALL BASE MATERIAL. OUTLINED CONCRETE IS TO BE SAW CUT AND

REMOVED.

3. DEMOLISH PLUMBING FIXTURES AND ALL EXISTING ACCESSORIES. SEE P-SHEETS FOR ADDITIONAL

INFORMATION.

4. DEMOLISH EXISTING MASONRY WALLS.

5. SEE E-SHEETS FOR WORK TO EXISTING LIGHTING.

6. SEE E-SHEETS AND M-SHEETS FOR WORK TO EXISTING EXHAUST FAN.

7. SEE A-104 FOR DEMOLITION OF EXISTING BRICK AND CMU WALL FOR CREATION OF NEW OPENING.

DEMOLITION GENERAL NOTES:

1. CONTRACTOR SHALL FIELD VERIFY ALL EXG. DIMENSIONS AND CONDITIONS & MAKE MINOR ADJUSTMENTS AS

NECESSARY. NOTIFY THE A/E OF ANY DISCREPANCIES WHICH MAY AFFECT THE WORK.

2. EXISTING CONSTRUCTION / FINISHES DISTURBED DURING DEMOLITION / CONSTRUCTION / RENOVATION SHALL

BE RESTORED TO A CONDITION AT LEAST EQUAL IN MATERIAL AND APPEARANCE TO THAT WHICH EXISTED

BEFORE THE WORK BEGAN.

3. ALL MATERIAL REMOVED DURING DEMOLITION SHALL BE REMOVED FROM THE SITE UNLESS OTHERWISE

NOTED OR INDICATED.

4. USING AGENCY SHALL BE RESPONSIBLE FOR REMOVING MOVEABLE FURNITURE & EQUIPMENT FROM THE

AREAS OF THE WORK. HOWEVER, CONTRACTOR SHALL BE PREPARED TO DEMOLISH, REMOVE & LEGALLY

DISPOSE OF MINOR CASEWORK, WINDOW TREATMENTS, SIGNAGE, ETC. CONSIDERED TO BE COMMENSURATE

WITH THE DEMOLITION INDICATED.

5. SEE OTHER TRADE SHEETS FOR ADDITIONAL DEMOLITION INFORMATION.

KEYED NOTES:

1. UTILITY SINK - SEE P-SHEETS

2. 4” CONCRETE SLAB W/ 6”X6” W1.4 X W1.4 WWF (CENTERED IN SLAB) OVER 10 MIL POLY

VAPOR RETARDER OVER 4” COMPACTED AGGREGATE - DOWEL NEW CONC. TO EXG. W/

12” LONG #4 DOWELS @ 18” O.C.. USE ½” EXPANSION JOINT MATERIAL BETWEEN NEW &

EXG. CONC.

3. 1/4" THICK BY 1'-2" STAINLESS STEEL FLAT PLATE THRESHOLD WITH BEVELED EDGES

AND HOLES FOR COUNTERSUNK FASTENERS.

4. CONTRACTOR TO CONSTRUCT PLASTIC TEMPORARY PARTITION PRIOR TO ANY

CONSTRUCTION. PARTITION TO BE 18'-4" +/- BY 8'-0" +/- TALL.

5. TOUCH UP PAINT ON CMU WALL FROM REMOVED ELECTRICAL WIRE MOLD - SEE

E-SHEETS.

SCALE:

DEMO PLAN

A-101

1

3/8" = 1'-0"

NORTH

SCALE:

FLOOR PLAN

A-101

2

3/8" = 1'-0"

X

X

SCALE:

WALL TYPE DETAILS

A-101

3

1" = 1'-0"

ROOM FINISH SCHEDULE

Room Name

Room

No. Floor Base North Wall East Wall South Wall West Wall Ceiling Finish

Ceiling

Height

CORRIDOR 100 LVT RB GYP/PT GYP/PT GYP/PT GYP/PT

ROOM FINISH SCHEDULE ABBREVIATIONS:

GYP - GYPSUM BOARD

PT - PAINT

RB - RUBBER BASE

LVT - LUXURY VINYL TILE

ROOM FINISH SCHEDULE GENERAL NOTES:

1. SEE SPEC SECTION 09 21 16 FOR INFORMATION ON

GYPSUM BOARD ASSEMBLIES.

2. SEE SPEC SECTION 09 65 00 FOR INFORMATION ON VCT

AND RUBBER BASE.

3. SEE SPEC SECTION 09 90 00 FOR INFORMATION ON

PAINT.

STORAGE 101

TOILET 102

LVT RB

LVT RB

GYP/PT GYP/PT GYP/PT

GYP/PT GYP/PT GYP/PT

GYP/PT

GYP/PT

GYP/PT

GYP/PT

GYP/PT

8'-2"+/-

8'-2"+/-

8'-2"+/-

DOOR SCHEDULE

DOOR

No.

SIZE SIZE SIZE DOOR FRAME

SIGN

H.W.

Set

Details Details Details

Width Height Thick Mat. Finish Elev. Mat. Finish Elev. Head Jamb Sill

102 3' - 0" 7' - 0" 1 3/4" WD PF A HM PT 1 A 1 4A 4B --

DOOR SCHEDULE ABBREVIATIONS:

HM

PF

PT

WD

- HOLLOW METAL

- PRE-FINISHED

- PAINT

- WOOD

DOOR SCHEDULE GENERAL NOTES:

1. SEE SPEC SECTION 08 12 14 FOR INFORMATION ON STANDARD STEEL FRAMES.

2. SEE SPEC SECTION 08 14 16 FOR INFORMATION ON FLUSH WOOD DOORS.

3. SEE SPEC SECTION 08 71 00 FOR INFORMATION ON DOOR HARDWARE.

SCALE:

DOOR DETAILS

A-101

4

1" = 1'-0"

SCALE:

OPENING DETIAL

A-101

5

1" = 1'-0"

Page 4: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

1

2

2"

2'-9 1/2"

2" 2"

2'-9"

2"

6'-8"

2"

2"

2"

3'-1 1/2" 3'-1"

3

5'-0"

1'-2"

A

B

C

1

6" 3'-0"

3'-0

"

1'-5

"

1'-6"

6" 8"

9"

2'-3

"

2'-5

"

2'-1

0"

3'-4

"

1'-5

"

3'-0

"

8"

3'-6" 1'-0"

2'-3

"

3

2

4

2

1

6

1

3

5

7

A 1

2" 3'-0" 2"

3'-4"

2"

3'-0"

7'-0"

7'-0"

7'-2"

1"

6"

10"

TOILET

A

2"

ADAAG COMPLIANT

CHARACTERS (TYP.)

BRAILLE TYP.

3/8"

HEAD

A

JAMB

CB

SILL

4 1/2"

2"

1"

2"

2"

EXISTING

MASONRY

EXISTING STEEL

ANGLE - PREP,

PRIME & PAINT

SEALANT - BOTH

SIDES

ALUMINUM

STOREFRONT

1" INSUL. GLASS

EXISTING

CONCRETE

1" INSULATED

MTL. PANEL

ALUM.

STOREFRONT

SPRAY FOAM

INSULATION

2X4 STUDS

@ 16" O.C.

1

2

" GYP. BOARD

SILL RECEPTOR &

DAM W/ WEEPS SET

IN A FULL BED OF

MASTIC

4 1/2"

2"

1"

EXISTING

MASONRY

SEALANT - BOTH

SIDES

ALUMINUM

STOREFRONT

1" INSUL. GLASS

SPRAY FOAM

INSULATION

2X4 STUDS

@ 16" O.C.

1

2

" GYP. BOARD

5

8

" GYP. BOARD CEILING

EXISTING ROOFING /

DECKING - NO WORK

6-1/2" THICK CLOSED CELL

POLYURETHANE SPRAY FOAM

INSULATION (MIN. R-VALUE OF

6 PER INCH OF THICKNESS)

EXISTING 2X WOOD

ROOF JOISTS

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

ELEVATIONS AND

DETAILS

TLD NAL TLD

A-102

DEMOLITION KEYED NOTES:

1. DEMOLISH EXISTING LIGHT FIXTURE AND

BACK BOX.

KEYED NOTES:

1. ALUMINUM STOREFRONT SYSTEM W/ 1"

INSULATED METAL PANEL.

2. ALUMINUM STOREFRONT SYSTEM W/ 1"

INSULATED GLASS.

3. INFILL DEMOLISHED BACK BOX WITH BRICKS

TO MATCH EXISTING. REMOVE EXISTING

BRICK PIECES AS NECESSARY TO ENSURE

FULL BRICKS ARE INSTALLED, FEATHERED

INTO EXISTING BRICKS.

SCALE:

NEW ELEVATION

A-102

2

3/8" = 1'-0"

SCALE:

DEMO ELEVATION

A-102

1

3/8" = 1'-0"

X

X

SCALE:

TOILET ELEVATION

A-102

4

3/8" = 1'-0" SCALE:

TOILET ELEVATION

A-102

5

3/8" = 1'-0" SCALE:

TOILET ELEVATION

A-102

6

3/8" = 1'-0"

TOILET ACCESSORY SCHEDULE

2

6

4

5

3

1

DESCRIPTIONREMARKS

40"

36"

30"

40"

19"

40"

SURF. MOUNT TOILET TISSUE DISPENSER

GRAB BARS; 36" AND 42" LONG

18"x30" FRAMED MIRROR

PAPER TOWEL DISPENSER

SURF. MOUNT SAN. NAPKIN DISPOSAL

SURF. MOUNT SOAP DISPENSER

INSTALL TO CENTER OF ROLL

INSTALL TO TOP OF UNIT

INSTALL TO BTM. OF REFLECTIVE SURF.

INSTALL TO BOTTOM OF UNIT

INSTALL TO TOP OF UNIT

INSTALL TO BOTTOM OF UNIT

MOUNT.

HEIGHT

SCALE:

DOOR AND FRAME ELEVATION

A-102

3

3/8" = 1'-0"

SCALE:

TOILET ELEVATION

A-102

7

3/8" = 1'-0"

GENERAL NOTES:

1. PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTED

OTHERWISE. DO NOT SCALE DRAWINGS - USE DIMENSIONS.

2. PROVIDE & INSTALL BLOCKING BEHIND ALL WALL MOUNTED ITEMS INDICATED IN

DRAWINGS AND SPECIFICATIONS.

3. UNLESS OTHERWISE NOTED OR DIMENSIONED, ALL DOORS SHALL BE INSTALLED

WITH A MINIMUM OF 12” CLEAR SPACE FROM EDGE OF DOOR TO NEAREST WALL OR

OBSTRUCTION ON PUSH SIDE OF DOOR AND WITH A MINIMUM OF 18” CLEAR SPACE

FROM EDGE OF DOOR TO NEAREST WALL OR OBSTRUCTION ON PULL SIDE OF DOOR.

4. UNLESS NOTED OTHERWISE, ALL WALL FRAMING AND SHEATHING IS TO EXTEND TO

BOTTOM CHORD OF TRUSSES.

7--BABY CHANGING STATION BY OWNER, PROVIDE BLOCKING

SCALE:

CEILING DETAIL

A-102

8

3/8" = 1'-0" SCALE:

SIGNAGE DETAIL

A-102

9

1 1/2" = 1'-0" SCALE:

STOREFRONT DETAILS

A-102

10

1" = 1'-0"

Page 5: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

1

2

3

2

3

4

4

4

2

10'-8"

5'-3

"

3'-4" 3'-4"

3'-4"

1

3

4

4

4

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

ALTERNATE BID #1

INFORMATION

TLD TLD TLD

A-103

NORTH

DEMOLITION KEYED NOTES:

1. DEMOLISH EXISTING CMU PARTITION. ENSURE NO DAMAGE IS CREATED TO EXISTING CEILING TILES (ASSUMED

TO CONTAIN ASBESTOS) NOR ADJACENT CMU PARTITIONS TO REMAIN.

2. DEMOLISH EXISTING WALL BASE MATERIALS AND PREPARE LOWER WALL SURFACE FOR NEW BASE.

3. PREPARE EXISTING TERRAZZO FLOORING FOR NEW CARPET TILE AS RECOMMENDED BY ADHESIVE

MANUFACTURER.

4. REMOVE DOOR SLAB FROM EXISTING HOLLOW METAL FRAME.

KEYED NOTES:

1. TOOTH IN NEW CMU, FULL DEPTH OR SOAPS AS NECESSARY, INTO VOIDS CREATED BY DEMOLISHED

ADJACENT CMU PARTITION. PREP, PRIME AND PAINT WALLS FROM FLOOR TO CEILING AROUND ENTIRE

PERIMETER OF THE ROOM.

2. PROVIDE AND INSTALL NEW CARPET TILE (SUPPLIED BY OWNER) AND 4" RUBBER BASE.

3. PROVIDE AND INSTALL RIPPED 2X10 1X PINE WOOD LUMBER AT VOID BETWEEN EXISTING CEILING TILES

CREATED BY DEMOLISHED CMU PARTITION. PREP, PRIME AND PAINT WOOD LUMBER.

4. PROVIDE AND INSTALL NEW PARTITION CONSISTING OF RIPPED 2X STUDS W/

1

2

" GYPSUM BOARD ON BOTH

SIDES TO MATCH THICKNESS OF EXISTING CMU PARTITION (ASSUMED TO BE 7-5/8" THICK). SKIM COAT AND

TEXTURE GYPSUM BOARD TO RESEMBLE TEXTURE OF EXISTING CMU. PROVIDE AND INSTALL THIN WOOD

BLOCKING ON FACES OF HOLLOW METAL FRAME TO SUPPORT EDGES OF GYPSUM BOARD. PREP, PRIME AND

PAINT GYPSUM BOARD.

SCALE:

DEMO PLAN

A-103

1

1/4" = 1'-0"

NORTH

SCALE:

FLOOR PLAN

A-103

2

1/4" = 1'-0"

X

X

GENERAL NOTES:

1. IF ALTERNATE BID #1 IS AWARDED, WORK TO EXISTING TOILET ROOM CANNOT COMMENCE BEFORE

SUBSTANTIAL COMPLETION OF BASE BID TOILET RENOVATION.

2. PATCH EXISTING TERRAZZO FLOOR IN EXISTING TOILET AND USE SELF-LEVELING COMPOUND AS NECESSARY

DUE TO DEMOLITION OF EXISTING PIPING AND PARTITION - SEE P-SHEETS.

3. NO ALTERNATE BID #1 RELATED TO THE EXISTING TOILET ROOM SHALL BEGIN UNTIL THE BASE BID WORK IS

SUBSTANTIALLY COMPLETE.

Page 6: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

CMU DEMOBRICK DEMO

PROPOSED

8" MIN.

PROPOSED OPENING

8" MIN.

8" MIN.

PROPOSED OPENING

8" MIN.

L4X4X5/16

TOOTH IN NEW FULLY GROUTED

CMU AND BRICK VENEER.

CMU TO BE REMOVEDBRICK TO BE REMOVED

7'-4" FINISHED

OPENING HEIGHT

7'-4" ABOVE

FINISHED FLOOR

8'-8" TOP OF WALL 8'-8" TOP OF WALL

7'-4" FINISHED

OPENING HEIGHT

L5X5X5/16

8'-8" TOP OF WALL

8" MIN. PROPOSED OPENING 8" MIN.

1

4

" DIA. HILTI KWIK-CON II+

OR EQUAL @ 24" O.C.

BRICK TO BE

REMOVED

EXISTING WIDTH

PROPOSED DOOR

OPENING

EXISTING CMU

EXISTING WIDTH

DEMO PROPOSED

EXISTING CMU

TO REMAIN

L5X5X5/16

8'-8" TOP OF WALL

7'-4" FINISHED

OPENING HEIGHT

8'-8" TOP OF WALL

7'-4" FINISHED

OPENING HEIGHT

L4X4X5/16

TEMPORARILY

SUPPORT ROOF

STRUCTURE AS

REQUIRED

REINSTALL

EXISTING

BRICK

CMU TO BE

REMOVED

DEMO

EXISTING CMU

TO REMAIN

L5X5X5/16

8'-8" TOP OF WALL

7'-4" FINISHED

OPENING HEIGHT

1/4" Ø HILTI KWIK CON

II+ OR EQUIVALENT @

2'-0" O.C., TYP.

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

STRUCTURAL DETAILS

TLD NAL TLD

A-104

SCALE:

DEMO DETAIL

A-104

1

1 1/2" = 1'-0"

SUGGESTED SEQUENCE OF CONSTRUCTION:

1. VERIFY ALL DIMENSIONS AND ELEVATIONS.

2. SEE A SHEETS FOR WORK TO CEILINGS.

3. TEMPORARILY SUPPORT ROOF FRAMING AS REQUIRED ON EXISTING BATHROOM SIDE OF WALL.

4. REMOVE PORTION OF BRICK AS INDICATED - SALVAGE FOR RE-USE.

5. INSTALL STEEL ANGLE FOR THE 8" CMU AND GROUT CELLS UNDER LINTEL BEARING.

6. REMOVE PORTIONS OF THE 8" CMU AS INDICATED.

7. CONSTRUCT NEW 8" CMU WALL SECTION.

8. INSTALL STEEL ANGLE FOR THE BRICK TO BE REINSTALLED.

9. INSTALL EXISTING BRICK AS INDICATED.

SCALE:

DEMO DETAIL

A-104

2

1 1/2" = 1'-0"

SCALE:

PROPOSED DETAIL

A-104

3

1 1/2" = 1'-0"

SCALE:

PROPOSED DETAIL

A-104

6

1 1/2" = 1'-0"SCALE:

DEMO DETAIL

A-104

4

1 1/2" = 1'-0" SCALE:

DEMO DETAIL

A-104

5

1 1/2" = 1'-0"

Page 7: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

1

2

3

3

WC-1

FD-1

LAV-1

COTF

1"

1"

US-1

PR

OV

ID

E / IN

ST

ALL V

ALV

E

IN

E

XIS

TIN

G V

AU

LT

OU

TS

ID

E B

UILD

IN

G

1

WH-1

4

5

6

WC-1

FD-1

LAV-1

COTF

4"

VENT UP

US-1

CO

NN

EC

T T

O E

XIS

TIN

G

WA

ST

E LIN

E U

ND

ER

FLO

OR

IN

SID

E B

UILD

IN

G

1

WH-1

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

PLUMBING PLANS

TLD NAL TLD

P-101

NORTH

SCALE:

DEMO PLAN

P-101

1

3/8" = 1'-0"

NORTH

SCALE:

SUPPLY FLOOR PLAN

P-101

2

3/8" = 1'-0"

DEMOLITION KEYED NOTES:

1. DEMOLISH EXISTING TOILET FIXTURE.

2. DEMOLISH EXISTING URINAL.

3. DEMOLISH EXISTING SINK.

4. ALTERNATE BID #1: DEMOLISH EXISTING WATER CLOSET AND ALL RELATED SUPPLY AND

SEWER PIPING. EXISTING PIPING SHALL BE MODIFIED/CAPPED IN ADJACENT MECHANICAL

ROOM TO THE SOUTH IN A MANNER THAT ENSURE CODE COMPLIANCE AFTER CONSTRUCTION

IS COMPLETE.

5. ALTERNATE BID #1: DEMOLISH EXISTING LAVATORY AND ALL RELATED SUPPLY AND SEWER

PIPING. EXISTING PIPING SHALL BE MODIFIED/CAPPED IN ADJACENT MECHANICAL ROOM TO

THE SOUTH IN A MANNER THAT ENSURE CODE COMPLIANCE AFTER CONSTRUCTION IS

COMPLETE.

6. ALTERNATE BID #1: DEMOLISH ALL SUPPLY AND SEWER PIPING FROM REMOVED WATER

CLOSET AND LAVATORY. MODIFIED/CAPPED IN ADJACENT MECHANICAL ROOM TO THE SOUTH

IN A MANNER THAT ENSURE CODE COMPLIANCE AFTER CONSTRUCTION IS COMPLETE.

KEYED NOTES:

1. PROVIDE AND INSTALL NEW TANKLESS WATER HEATER PER SCHEDULE.

X

X

GENERAL NOTES:

1. REFER TO ARCHITECTURAL SHEETS FOR EXACT

LOCATION OF PLUMBING FIXTURES. REFER TO

ARCHITECTURAL SHEETS FOR WALL AND FLOOR

FINISHES.

2. CONTRACTOR SHALL COORDINATE THE

INSTALLATION OF ALL WATER, SANITARY, AND

VENT PIPING, VALVES, AND APPURTENANCES WITH

RELATED STRUCTURAL, HEATING, VENTILATING,

MECHANICAL EQUIPMENT AND ELECTRICAL

COMPONENTS AND DEVICES.

3. ALL FIXTURES AND PIPING SHALL BE SIZED,

VENTED AND TRAPPED IN ACCORD WITH THE

CURRENT EDITION OF THE INTERNATIONAL

PLUMBING CODE.

4. FOR CLARITY ON PLANS, NOT ALL VENT PIPING IS

SHOWN. CONTRACTOR SHALL GROUP VENT PIPING

AND ROUTE TO NEAREST ADJACENT V.T.R. AS

REQUIRED.

5. ANY PIPING EXPOSED IN PLENUM RETURN AREAS

SHALL BE PLENUM RATED OR WRAPPED IN

APPROVED, PLENUM RATED INSULATION.

6. INSTALL FIXTURES TO HEIGHTS ABOVE FINISHED

FLOOR AS INDICATED ON ARCHITECTURAL SHEETS

AND IN SPECIFICATION SECTION 22 40 00.

NORTH

SCALE:

ALT. BID #1 DEMO PLAN

P-101

4

1/4" = 1'-0"

PLUMBING FIXTURE SERVICE SCHEDULE

TAG WASTE TRAP VENT COLD HOT

WC-1 3" INTEGRAL 2" 1/2" --

LAV-1 1-1/2" 1-1/2" 1-1/4" 3/8" 3/8"

US-1 1-1/2" 1-1/2" 1-1/4" 1/2" 1/2"

FD-1 3" 3" 2" -- --

NOTE:

1. ALL FIXTURE WATER SUPPLY SERVICE SIZES SHALL BE

INCREASED ONE FULL PIPE SIZE AT ALL LOCATIONS WHERE

PEX TUBING IS INDICATED TO BE PROVIDED.

2. LAV-1 SHALL RECEIVE TMV.

NORTH

SCALE:

WASTE FLOOR PLAN

P-101

2

3/8" = 1'-0"

TANKLESS WATER HEATER SCHEDULE

TAG

BASIS OF DESIGN

MANUFACTURER

BASIS OF

DESIGN

MODEL

TYPE UEF

MAXIMUM

GPM @

60° TEMP

RISE

WATTAGE

(kW)

VOLTAGE

(V)

WH1 AO SMITH R4LA-180E

ELECTRIC

0.92 2.0 18 240

AMPERAGE

(A)

ACTIVATION

GPM

75

0.25

HOT/COLD

CONNECTIONS

3/4" NPT

Page 8: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

1

1

1

1

EF-1

EF-1

MS-1

CU-1

3

4

4

2

3/8" SUCTION

1/4" LIQUID

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

MECHANICAL PLANS

TLD GBS J?S

M-101

NORTH

SCALE:

DEMO PLAN

M-101

1

3/8" = 1'-0"

NORTH

SCALE:

FLOOR PLAN

M-101

2

3/8" = 1'-0"

DEMOLITION KEYED NOTES:

1. DEMO EXISTING EXHAUST FAN, DUCTWORK AND WALL CAP.

KEYED NOTES:

1. PROVIDE AND INSTALL PRE-FINISHED METAL WALL CAP FOR EXHAUST DUCT.

2. PROVIDE AND INSTALL NEW MINI-SPLIT PER SCHEDULE.

3. PROVIDE AND INSTALL NEW CONDENSING UNIT PER SCHEDULE.

4. PROVIDE AND INSTALL NEW EXHAUST FAN PER SCHEDULE AND DUCTWORK.

X

X

MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF OUTDOOR UNIT SCHEDULE

SYSTEM TAG TAG REFERENCE M-NET ADDRESS MODEL NUMBER MODULES

NOMINAL COOLING

CAPACITY (BTU/h)

REFRIG PIPE DIM

HIGH/LOW

PRESSURE (INCH)

(SEE NOTE 4)VOLTAGE / PHASE

MCA 208/230 OR

[460V] RFS MOCP NOTES / OPTIONS

208/230 OR [460V]

ELECTRICAL-PER MODULE

SYSTEM 1 CU-1 51 MUZ-GL12NA GL12 12,000.0 14,400 3/8 / 1/4 208/23V / 1-PHASE 9 15 15

NOMINAL HEATING

CAPACITY (BTU/h)

1, 2, 3, 4, 5

1.

2.

3.

4.

5.

NOTES & OPTIONS:

NOMINAL COOLING CAPACITIES ARE BASED ON INDOOR

COIL EAT OF 80/67°F (DB/WB), OUTDOOR OF 95°F (DB)

NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR

COIL EAT OF 70°F (DB), OUTDOOR OF 43°F (WB)

EFFICIENCY VALUES FOR EER, IEER, COP ARE BASED

ON AHRI 1230 TEST METHOD FOR MIXTURE OF DUCTED

AND NON-DUCTED

FOR SYSTEMS WITH MULTIPLE MODULES, REFRIGERANT

PIPE DIMENSIONS INDICATE TOTAL SYSTEM COMBINED

PIPING.

ADDED FIELD CHARGE LISTED IS IN ADDITION TO

FACTORY CHARGE, THIS MUST BE UPDATED BASED

UPON FINAL AS-BUILT PIPING

MITSUBISHI ELECTRIC TRANE HVAC US: CITY MULTI VRF INDOOR UNIT SCHEDULE

SYSTEM TAG ROOM NAME MODEL NUMBER TYPE

NOMINAL COOLING

CAPACITY (BTU/h) VOLTAGE / PHASE NOTES / OPTIONS

NOMINAL HEATING

CAPACITY (BTU/h)

1.

2.

3.

4.

5.

6.

NOTES & OPTIONS:

NOMINAL COOLING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 80/67°F (DB/WB),

OUTDOOR OF 95°F (DB)

NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 70°F (DB), OUTDOOR

OF 43°F (WB)

SEE OUTDOOR UNIT SCHEDULE FOR OUTDOOR AMBIENT CONDITIONS, CONNECTED

CAPACITY, AND OTHER FACTORS ASSOCIATED

SEE SCHEMATIC PIPING/CONTROL DIAGRAM FOR INDICATION OF REQUIRED INDOOR UNIT

REMOTE CONTROLLERS, SYSTEM

FULL DEMAND CORRECTED CAPACITY INCLUDES DE-RATE ASSOCIATED WITH INDOOR VS.

OUTDOOR CONNECTED CAPACITY INDICATED ON OUTDOOR UNIT SCHEDULE FOR

ASSOCIATED SYSTEM. PARTIAL CORRECTED CAPACITY ASSUMES SUFFICIENT DIVERSITY

EXISTS SUCH THAT THE CONNECTED CAPACITY DE-RATE DOES NOT APPLY. IT IS THE

DESIGNER'S RESPONSIBILITY TO ENSURE "DIAMOND SYSTEM BUILDER" IS SET IN THE

APPROPRIATE OUTPUT CAPACITY SETTING (FULL DEMAND/PARTIAL DEMAND) PRIOR TO

GENERATING THIS SCHEDULE.

IT IS RECOMMENDED TO ALWAYS BASE HEATING CORRECTED CAPACITY ON FULL

DEMAND.

TAG REFERENCE

POWER COOLING

208V/230V (kW)

POWER HEATING

208V/230V (kW)

ELECTRICAL

MCA/MFS

SYSTEM 1 OFFICE 16 EC-3 MSZ-GL12NA WALL MOUNTED TYPE 12,000.0 14,400 208/230V/1-PHASE 0.9 1.1 1, 2, 3, 4, 5, 61/15

EXHAUST FAN SCHEDULE

TAG

BASIS OF DESIGN

MANUFACTURER

BASIS OF

DESIGN

MODEL

REQUIRED

AIRFLOW

(CFM)

FAN

TYPE

OUTLET

DUCT

SIZE

ELECTRICAL DATA

VOLTAGE

MAX

AMPS

EF-1 GREENHECK SP-AP0511W 80

CEILING

MOUNTED

4" Dia. 120 0.26

EXHAUST FAN SCHEDULE NOTES:

1) EXHAUST FANS SHALL HAVE MOTOR WITH THERMAL OVERLOAD PROTECTION AND SHALL BE

NON-OVERLOADING.

3) EXHAUST FANS SHALL COME WITH FACTORY INSTALLED SPEED CONTROLLER.

4) EXHAUST FANS SHALL BE INTERLOCKED WITH LIGHT SWITCHES SO AS TO RUN WHEN THE

BATHROOMS ARE OCCUPIED.

Page 9: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

ELECTRICAL

LEGENDS

& SCHEDULES

DMT GBS J?S

E-001

GENERAL PANELBOARD NOTES:

1. PANELBOARD WHERE WORK IS DONE IS EXISTING TO REMAIN. ELECTRICAL CONTRACTOR TO

INSTALL NEW BREAKERS IN PANELBOARD AS SHOWN ON THE PANELBOARD SCHEDULE WITH OVER

CURRENT PROTECTION AND FAULT CURRENT RATING SHOWN.

2. EXISTING PANELBOARD IS EATON CH STYLE WITH CH BREAKERS. NEW BREAKERS INSTALLED ARE

TO MATCH EXISTING MANUFACTURER AND MODEL SERIES.

3. ELECTRICAL CONTRACTOR TO PRESERVE THE INTEGRITY AND WIRING OF ALL EXISTING CIRCUITS

IN PANELBOARD UNLESS OTHERWISE SHOWN ON DEMOLITION PLAN. ELECTRICAL CONTRACTOR TO

VERIFY ALL CIRCUITS ARE IN FUNCTIONING ORDER UPON PROJECT CLOSEOUT.

4. ALL NEW FEEDERS INSTALLED IN PANELBOARD FOR BRANCH CIRCUITS SHALL HAVE THE

APPROPRIATE TYPE OF INSULATION AND TEMPERATURE RATING FOR ITS INTENDED USE.

Panelboard Legend

(#)CONNECT NEW CIRCUIT TO EXISTING BREAKER INPANELBOARD

(EX) EXISTING CIRCUIT WHERE NO LOAD IS ADDED TO

(-->)CONNECT EXISTING CIRCUIT TO NEW BREAKER INPANELBOARD

(0)-----(0) MOCP THERMAL MAGNETIC BREAKERNO SYMBOL, BREAKER AND FEEDER SHOWN ARE NEW

SYMBOL

MOUNTING

120V, 20A, DUPLEX POWER RECEPTACLE

DESCRIPTION

ELECTRICAL LEGEND

WALL @ 18" AFF

FLOOR/TABLE

CEILING

WALL @ 18" AFF

120V, 20A, DUPLEX POWER RECEPTACLE

120V, 20A, DUPLEX POWER RECEPTACLE

120V, 20A, QUAD POWER RECEPTACLE

DRY-TYPE FLOOR MOUNTED TRANSFORMERFLOOR

ELECTRIC PANELBOARD, REFER TO PANELBOARD SCHEDULES FOR

MORE INFORMATION

WALL @ 44" AFF TO CENTER

ELECTRICAL WIRE

CIRCUIT WIRE SHOWN FOR SCHEMATIC PURPOSES ONLY ARROWS

INDICATE CIRCUIT HOMERUN, TICKS INDICATE PHASES + NEUTRAL

UNFUSED DISCONNECT, SIZES VARY WITH AMPERAGE

WALL @ 44" AFF TO CENTER

120V, STEEL 4" X 4" X 2-1/2" JUNCTION BOX WITH KNOCKOUTS

WALL @ 42" AFF

WALLJ

120V, 20A, DUPLEX POWER RECEPTACLE WITH GFCI PROTECTION

S

S

S

WALL @ 44" AFF

WALL @ 44" AFF

CEILING

120V SINGLE POLE SINGLE THROW SWITCH FOR CONTROL OF LIGHTING

WALL PLATE TO MATCH WALL

120V DUAL TECHNOLOGY OCCUPANCY SENSOR FOR AUTOMATIC

CONTROL OF LIGHTING. WALL PLATE TO MATCH WALL

120V DUAL TECHNOLOGY OCCUPANCY SENSOR FOR AUTOMATIC

CONTROL OF LIGHTING. WALL PLATE TO MATCH WALL

Panel Name: Panel A Lug Type: MOCP

208/120V 1PHCasing: NEMA 1

Fault Current: 35kVA Surface MountedAmperage Rating : 200A Phase: Existing to Remain

(0) 200A (0)

Breaker # Description OCP(A) VD% Feeder Load Load Feeder VD% OCP(A) Description Breaker #1 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 23 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 45 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 67 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 89 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 1011 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 1213 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 1415 (EX) 20 -- ETR ETR ETR ETR -- 20 1617 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 1819 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 2021 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 2223 (EX) 20 -- ETR ETR ETR ETR -- 20 (EX) 24

25 CU-1 15 0.70% (3)#10 AWG &(1)#10 AWG GRND 936VA 89W

(3)#10 AWG &(1)#10 AWG GRND 0.85% 20 WH-1

2627 936VA -------- -------- -------- N/A -------- 2829

MS-1 15 1.20% (3)#10 AWG &(1)#10AWG GRND

208VA -------- -------- -------- N/A -------- 3031 208VA -------- -------- -------- N/A -------- 3233 -------- N/A -------- -------- -------- -------- -------- -------- N/A -------- 3435 -------- N/A -------- -------- -------- -------- -------- -------- N/A -------- 3637 -------- N/A -------- -------- -------- -------- -------- -------- N/A -------- 3839 -------- N/A -------- -------- -------- -------- -------- -------- N/A -------- 4041 -------- N/A -------- -------- -------- -------- -------- -------- N/A -------- 42

Total New Load: Phase A: 1233 VAPhase B: 1144 VA Total New Amperage:

11.4 ATotal: 2377 VA

Mechanical Equipment Coordination Schedule

Equipment Name Equipment Type Manufacturer Model # Wattage Supply Voltage Amperage Load Class Control Type MOCP Supply Wire AWG Local Disconnect

CU-1 Condensing Unit Mitsubishi MSZ-GL12NA 0.6 kW 208V 1PH N/A Cooling T-stat relays 15A

(3) #10 AWG CU & (1)#10 AWG CU GRND IN3/4" CONDUIT

NEMA 3R WALLMOUNTED

MS-1Split SystemIndoor Fan Mitsubishi MSZ-GL12NA 208W 208V 1PH 1A Motor T-stat relays 15A

(3) #10 AWG CU & (1)#10 AWG CU GRND IN3/4" CONDUIT N/A

EF-1 Exhaust Fan Greenheck SP-AP0511W 30W 120V 1PH 0.25A Motor

Light SwitchManual/ Occupancy

Sensor Automatic 20A

(2) #12 AWG CU & (1)#12 AWG CU GRND IN3/4" CONDUIT LIGHT SWITCH

WH-1 Water Heater AO Smith CT-199i-N 89W 120V 1PH 6.2A Non-Continous Internal 20A

(2) #12 AWG CU & (1)#12 AWG CU GRND IN3/4" CONDUIT N/A

Note: All equipment shown is provided and installed by the HVAC contractor. Electrical contractor to provide any electrical feedsnecessary for proper installation and controling of equipment.

Page 10: SEDARC - HURST-ROSCHE, INC. · 1 2" air gap. sealant - both sides jamb - head sim. 2x4 studs @ 16" o.c. 2x wood trim - prime and paint 1x wood trim - prime and paint existing brick/block

4

3

2

3

2

1

1

EXISTING TO

REMAIN PANEL A

5

CU-1

WH-1

EM

A A

A

A

6

1

3

4

1

6

2

EXISTING TO

REMAIN PANEL A

J

MS-1

EF-1

EF-1

A-EXISTING

A-EXISTING

A-26

A-25,27

A-29,31

7 8 7

A-EXISTING

J

18" AFF

CHECK:DRAWN:DESIGN:

2020 HURST-ROSCHE, INC.

PROJECT NO:

SIGNATURE

DIV

ER

NO

N, S

AN

GA

MO

N C

OU

NT

Y, IL

LIN

OIS

22

1 S

OU

TH

S

EC

ON

D S

TR

EE

T

DIV

ER

NO

N T

OW

NS

HIP

L

IB

RA

RY

TO

IL

ET

R

EN

OV

AT

IO

NS

DATEMK. DESCRIPTION

DATE

LICENSE EXPIRES

150-1600

EAST ST. LOUIS, IL

MARION, IL

ARNOLD, MO

NEOSHO, MO

NASHVILLE, TN

DATE: 08-10-2020

11-30-2020

SIGNATURE

DATE

LICENSE EXPIRES

Hurst-Rosche, Inc.

PROFESSIONAL DESIGN NUMBER: 184-000298

www.hurst-rosche.com

08-10-2020

1400 E. TREMONT ST.

HILLSBORO, IL

PH: 217.532.3959

L

I

C

E

N

S

E

D

AR

C

H

I

T

E

C

T

S

T

A

T

E

O

F

I

L

L

I

N

O

I

S

TIMOTHY L

DOWNEN

001.021928

ELECTRICAL PLANS

TLD GBS J?S

E-101

NORTH

SCALE:

DEMO PLAN

E-101

1

3/8" = 1'-0"

NORTH

SCALE:

FLOOR PLAN

E-101

2

3/8" = 1'-0"

DEMOLITION KEYED NOTES:

1. DEMO EXISTING LIGHT FIXTURE AND BACK BOX. EXISTING WIRING AND CONDUIT TO REMAIN FOR

EXTENSION TO NEW LIGHT FIXTURES.

2. DEMO EXISTING RECEPTACLE, BACK BOX AND ASSOCIATED IN-WALL WIRING AND

CONDUIT. ASSOCIATED IN-CEILING WIRING AND CONDUIT TO REMAIN FOR EXTENSION TO NEW

RECEPTACLES.

3. DEMO EXISTING SWITCH, BACK BOX AND ASSOCIATED WIRING / CONDUIT BACK TO SOURCE.

4. DEMO EXISTING EXTERIOR LIGHT FIXTURE, BACK BOX AND ASSOCIATED WIRING / CONDUIT BACK TO

SOURCE.

KEYED NOTES:

1. PROVIDE AND INSTALL NEW WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR/WALL

SWITCH INSTALLED AT 48" AFF. SWITCH IS TO BE MANUAL ON AND AUTOMATIC OFF. SENSOR IS

TO TURN OFF ROOM LIGHTS AFTER 20 MINUTES OF OCCUPANTS VACATING THE ROOM.

OCCUPANCY SENSOR IS TO BE ACUITY CONTROLS WSX-VA-WH.

2. CONNECT LIGHTS INDICATED TO EXISTING CIRCUIT. VERIFY TOTAL LOAD ON CIRCUIT IS LESS

THAN 80% OF FULL LOAD AMPERAGE. SHOULD LOAD BE LARGER THAN 80% CONNECT NEW

LIGHTS TO NEW CIRCUIT IN PANEL "A" WITH A 20A OVER CURRENT PROTECTION.

3. PROVIDE AND INSTALL RECEPTACLE AND CONNECT TO EXISTING CIRCUIT FEEDING THIS ROOM.

4. PROVIDE AND INSTALL NEW 4" X 4" X 2-1/2" JUNCTION BOX FOR WIRING TO HVAC SPLIT SYSTEM

UNIT CONCEALED INSIDE WALL. FOR PROPER INSTALLATION REFER TO MANUFACTURER

DRAWINGS. UTILIZE 12 AWG WIRE IN 1" EMT FOR CONTROL WIRING.

5. PROVIDE AND INSTALL NEW WALL MOUNTED NEMA 3R LOCAL DISCONNECT SWITCH FOR NEW

CONDENSING UNIT. PROVIDE A FLEXIBLE WHIP CONNECTION TO CU-1. WHIP CONNECTION IS TO

CONTAIN FEEDER INDICATED ON PANEL SCHEDULE. SEPARATE FLEXIBLE WHIP IS TO CONTAIN

CONTROL WIRING. REFER TO MANUFACTURER DRAWINGS AND COORDINATE WITH GENERAL

CONTRACTOR FOR PROPER UNIT INSTALLATION. REFER TO MECHANICAL COORDINATION

SCHEDULE ON SHEET E-001 FOR MORE INFORMATION.

6. CONNECT EXHAUST FAN TO ROOM LIGHTING CIRCUIT AND CONTROLS TO OPERATE FAN WHEN

ROOM LIGHTS ARE ON.

7. CONTRACTOR TO DEMO EXISTING SURFACE MOUNT WIRE MOLD AND ELECTRICAL WIRING FROM

MECHANICAL ROOM TO EXISTING OUTLET NEAR STOREFRONT WINDOW AND RE-ROUTE NEW

MATERIALS OVERHEAD TO AVOID CONFLICT WITH NEW MASONRY OPENING. SEE PHOTOS,

SHEET E-101, FOR ADDITIONAL INFORMATION.

8. PROVIDE AND INSTALL RECEPTACLE AND CONNECT TO RE-ROUTED WIRING INDICATED IN KEYED

NOTE #7. RECEPTACLE TO BE MOUNTED APPROXIMATELY 60” AFF WHERE INDICATED BY OWNER.

X

X

GENERAL NOTES:

1. LIGHTING FIXTURES SHALL BE MANUALLY CONTROLLED VIA LOCAL SWITCHES INDICATED WITHIN

ROOM. LIGHTING FIXTURES SHALL HAVE AUTOMATIC CONTROL VIA WALL MOUNTED DUAL

TECHNOLOGY OCCUPANCY SENSOR. EXTERIOR FIXTURES ARE TO BE PHOTOCELL CONTROLLED.

EMERGENCY FIXTURES (EM) ARE SHALL BE CONNECTED AHEAD OF ANY SWITCHING.

2. FIXTURES LABELED (R) ARE EXISTING FIXTURES THAT ARE RELOCATED AS SHOWN ON THE

REFLECTED CEILING PLAN. PRIOR TO ROUGH IN FOR RELOCATION OF EXISTING FIXTURES OR

INSTALLATION OF NEW FIXTURES E.C. IS TO COORDINATE EXACT LOCATION WITH ARCHITECT

DRAWINGS.

3. CEILING MOUNTED FIXTURES SHALL BE MOUNTED FLUSH TO GYPSUM BOARD CEILING. FIXTURES

ARE TO BE MOUNTED TO JUNCTION BOX AS WELL FOR ADDITIONAL SUPPORT. GRID CEILING

LUMINAIRES ARE TO BE MOUNTED IN GRID AND SUPPORTED BY HANGER WIRE RUNNING UP TO

STRUCTURE. REFER TO MANUFACTURERS DRAWINGS FOR PROPER INSTALLATION. ALL NEW

INTERIOR FIXTURES ARE TO BE MOUNTED WITH EQUAL SPACING BETWEEN EACH OTHER WITHIN

EACH ROOM.

LIGHTING FIXTURE SCHEDULE

Type Mark Description Manufacturer Model Lamp Electrical Data Mounting Type Count Comments

A 1' x 4' LED Lithonia TLX4-20L-FW-A12-LP840 INTEGRAL

LED

120 V/1-21 VA 4

EM Emergency Bug

Eyes

Lithonia EU2L M12 INTEGRAL

LED

120 V/1-3 VA Wall Surface

Mounted

1

Ceiling Surface

Mounted

LIGHT SHALL BE WIRED

AHEAD OF SWITCHING AND

HAVE FUNCTIONING TEST

SWITCH

SCALE:

PHOTOS

E-101

3

N.T.S.

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
GFCI +42