section i regulators - steam specialtycontents. pages showing popular combinations of pilot and...

18
SECTION I R EGULATORS

Upload: others

Post on 11-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

SECTION IREGULATORS

Page 2: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

Iron HorseED SeriesPressure

RegulatorPressures To 600 PSIGTemperatures to 750°F

Three Pilot Mounting Optionsinclude standard side mount (shown),

integral mount and remote mount

SECO Metal Seats and Discsresist wiredraw - not one case

of SECO Metal being cut by steam in 75 years

Packless Constructioneliminates leakage and greatly reduces friction

and stem wear

Two Main Spring Options

for superior regulation over a wide range

of applications

Large, Protected Metal Diaphragm

bathed in condensate, sealed away from steam

seldom needs replacement

No Closely Fitted Partsto stick or bind due to

uneven expansion or foreign matter

Few Moving Partsmean long service life

Applications● Pressure Regulation for Steam Distribution

● Single Point or Multiple Use Applications

● Pressure Control for Steam Plants

● District Heating Systems

● Single Stage Reduction Stations

● Two Stage Reduction Stations

● Parallel Reduction Stations

Springs Outside Steam Pathassure exceptionally long life on both Main Valve and Pilot

Easy Inspectionprovided by external diaphragm loading steam passages

GuaranteedDead End Shutoff meets Class IV in steamservice, even on large sizes

Patented SECOWELD Optionallows easy repair of seat ringthreads damaged by highpressure applications

Page 3: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

HOW TO CHOOSE A REGULATORIf you already know the product that you want information on, find the product page in the Table ofContents. Pages showing popular combinations of Pilot and Regulators are found in the CombinationRegulators Chapter. Detailed product information on materials, ratings, dimensions, weights and applica-tions are found in the Products Chapters. All sizing information is contained in the Regulator Sizing Chapter.

If you are not sure of what you need, collect all the following information. You will need it to select the rightproduct for your needs.

Inlet Pressure

Flow Rate

Flow Media (i.e.: Steam, Water, etc.)

Desired Delivery Pressure

Noise Restrictions, if any

Type of Pilot Control (i.e.: Self Contained, Pneumatic, Electronic, etc.)

Application (i.e.: Temperature Regulation, Single Stage Pressure Regulation, etc.)

Application data is listed on each Product Page. If you identify the nature of the installation, it will assistyou selecting the proper equipment.

DIRECT ACTING OR PILOT OPERATED REGULATOR?You may be able to use a Direct Operated Regulator for your application. They are generally less expen-sive than Pilot Operated Regulators. However, they do not provide the same level of accuracy or rangeability.

If a Direct Acting Regulator is an option, consult the Direct Operated Valves Chapter to determine whichbest fits your specific needs. Then, consult the appropriate pages in the Regulator Sizing Chapter toselect the exact size you need.

If a Pilot Operated Regulator is required, go to Page __ (for Pressure Regulators) or Page __ (forTemperature Regulators). These selection charts will help you to quickly determine the type of productthat you need. The Pilot can be self contained, pneumatically or electronically actuated. Consult theappropriate pages in the Regulator Sizing Chapter to select the exact size Regulator and Pilot you need.Overall dimensions of the most popular combinations are provided in the Combination Regulators Chapter.

ECONOMICAL, ENGINEERED OR ENGINEERED WITH NOISE SUPPRESSION?The choice of how to size a regulator for an application is up to you. The most economical choice doesnot necessarily take into consideration the optimum loading of the Regulator, which could affect it’sservice life. Properly engineered Spence Regulators have been in continuous service for as much as 50years. In high pressure reduction stations, noise can be a serious environmental problem. Spence offersa number of Noise Suppression products to reduce this problem. You will find comprehensive noisereduction sizing and selection information in the Noise Reduction Chapter.

Page 4: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

THE OPERATING CYCLE OF A SPENCE PRESSURE REGULATORThe basic Type ED has been selected to illustrate the operation of a SPENCE Pilot Operated Pressure Regulator.This presentation describes the successive steps in the mechanical cycle of the Regulator.

1MAIN VALVE is normally closed.On placing Regulator in service,

initial pressure fills the passagesshown in red.

3CONTROL LINE connectsPilot Diaphragm Chamber

to Delivery piping.

4ADJUSTING SPRING,when compressed,

forces Pilot Valve open.

5CONNECTING TUBINGconducts fluid from Pilot

to Main Valve Diaphragmand Bleedport. When Pilotopens, fluid flows throughPilot faster than it canescape at Bleedport, creatinga loading pressure (orange)which forces Main Valveopen.

6DELIVERY PIPE and Control Lineare now being filled with fluid

flowing through Main Valve.As delivery pressure (yellow) rises,

it overcomes the force exerted byAdjusting Spring and Pilot throttles.This , in turn, allows Main Valve tothrottle just enough to maintain theset delivery pressure.

If the demand ceases, Pilot closes,allowing the Main Valve to close –effecting a DEAD-END SHUTOFF.

2PILOT receivesinitial pressure

through Nipple andUnion Connection.

KEY

HIGH PRESSURE

MEDIUM PRESSURE

LOW PRESSURE

Page 5: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

THE OPERATING CYCLE OF A SPENCE TEMPERATURE REGULATORThe Type ET134 has been selected to illustrate the operation of a SPENCE Pilot Operated Temperature Regulator.This presentation describes the successive steps in the mechanical cycle of the Regulator.

1MAIN VALVE is normally closed. On placingRegulator in service, initial pressure fills the

passages shown in red.

3CONTROL LINE connects Pilot DiaphragmChamber to Delivery piping.

4PRESSURE SPRINGforces Pilot Valve open.

5CONNECTING TUBING conducts steam fromPilot to Main Valve Diaphragm and Bleedport.

When Pilot opens, steam flows through Pilot fasterthan it can escape at Bleedport, creating a loadingpressure (orange) which forces Main Valve open.

6HEATER, Delivery Pipe and ControlLine are now being filled with steam

flowing through Main Valve.As delivery pressure (yellow) rises, it

overcomes the force exerted by PressureSpring and Pilot throttles. This, in turnallows Main Valve to throttle just enoughto maintain the set delivery pressure.

7THERMOSTAT ELEMENT (vapor tension type) is connected into heater outlet.The rising temperature of the fluid (blue) being heated creates a vapor pressure

(green) on the Temperature Diaphragm. When this pressure has reached a pointsufficient to overcome the Temperature Adjusting Spring, it applies a force on theLever so as gradually to decrease the spring loading on the Pressure Diaphragm.This produces a stem-by-step reduction in the delivery pressure as the temperaturerises through several degrees.

If the desired temperature is exceeded, the vapor pressure on the PilotTemperature Diaphragm overcomes the forces of the Spring. This allows Pilot andMain Valve to close tight.

2PILOT receivesinitial pressure

through Nipple andUnion Connection.

KEY

INITIAL STEAM PRESSURE

LOADING STEAM PRESSURE

DELIVERY STEAM PRESSURE

VAPOR PRESSURE

FLUID HEATED

Page 6: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

QUICK SELECTION CHARTFOR STEAM PRESSURE REGULATORS

Review the application data that you have collected. Consult the chart, starting with the inlet pressure that matches the inletpressure you have. Next, select your outlet pressure (reduced or delivery pressure). Then select the type of pilot control that youwill be using and, finally, the level of accuracy that your system requires. This will lead you to a recommended regulator. Please bear in mind that these recommendations are general in nature and you should check the Product Pages and Sizing Sectionto ensure you have selected the correct product. If you need assistance, contact your local Spence Technical Sales Representative.

TYPE ED5

TYPE EA84

TYPE ED210ELECTRONIC*

PNEUMATIC

SELFACTUATED

INITIALPRESSURE

REDUCEDPRESSURE

SPENCEREGULATOR

TYPE OFCONTROL

NORMALREGULATIONACCURACY

± 1/2 PSIG1 PSIG

TO25 PSIG

TYPE ED

TYPE EA43

TYPE ED210ELECTRONIC*

PNEUMATIC

SELFACTUATED

± 1 PSIG3 PSIG

TO150 PSIG

TYPE ED2

TYPE EA70

TYPE ED210ELECTRONIC*

PNEUMATIC

SELFACTUATED

± 2 PSIGABOVE150 PSIG

15 PSIGOR

BELOW

TYPE E2D

TYPE E2A84

TYPE E2D210ELECTRONIC*

PNEUMATIC

SELFACTUATED

± 1 PSIG

TYPE E2D5

TYPE E2A84

TYPE E2D210ELECTRONIC*

PNEUMATIC

SELFACTUATED

± 1/2 PSIG

ABOVE15 PSIG

1 PSIGTO

12 PSIG

* Electronic Pilot accuracy is a function of controller accuracy.

Page 7: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

QUICK SELECTION CHARTFOR TEMPERATURE REGULATORS

Review the application data that you have collected. Consult the chart, starting with the inlet pressure that matches the inletpressure you have. Next, select your outlet pressure (reduced or delivery pressure). Then select the type of pilot control that youwill be using and, finally, the level of accuracy that your system requires. This will lead you to a recommended regulator. Please bear in mind that these recommendations are general in nature and you should check the Product Pages and Sizing Sectionto ensure you have selected the correct product. If you need assistance, contact your local Spence Technical Sales Representative.

* See Control Valve Section

TYPEET14

TYPEET14D

TYPEET134

TYPEET124

TYPEEAT61

TYPEE2T14

TYPEJT61*

TYPEE2T14D

TYPEE2AT61

STORAGE ORINSTANTANEOUS

STORAGE ORINSTANTANEOUS

STORAGE ORINSTANTANEOUS

STORAGE ORINSTANTANEOUS

STORAGE ORINSTANTANEOUS

STORAGE ORINSTANTANEOUS

STORAGE

INSTANTANEOUS20 PSI MAXIMUM

INSTANTANEOUS125 PSI MAXIMUM

INLETPRESSURE

OUTLETPRESSURE

SPENCEREGULATOR

HEATERTYPE

TYPE OFCONTROL

SELFCONTAINED

SELFCONTAINED

PNEUMATIC

PNEUMATIC

PNEUMATIC

SELFCONTAINED

SELFCONTAINED

NO PRESSUREREDUCTION

NO PRESSUREREDUCTION

REDUCEDPRESSURE

REDUCEDPRESSURE

15 PSIGOR

BELOW

ABOVE15 PSIG

Page 8: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

SPEN

CE

MA

INVA

LVE

SPEC

IFIC

ATIO

NTA

BLE

aM

ain

Valv

es fo

r cor

rosi

ve fl

uid

s or

cos

tly g

ases

req

uire

sp

ecia

l mat

eria

ls.

bB

ronz

e b

ody

and

blin

d f

lang

e on

ly.

cM

inim

um D

iffer

entia

l is

the

sm

alle

st p

erm

issi

ble

diff

eren

ce b

etw

een

initi

al

pre

ssur

e (m

easu

red

at

th

e in

let)

and

th

e d

eliv

ery

pre

ssur

e(m

easu

red

at

the

outle

t) of

the

mai

n va

lve.

dS

ecow

eld

sea

t con

stru

ctio

n d

escr

ibed

in O

ptio

ns S

ectio

n is

regu

larly

furn

ishe

d fo

r se

rvic

e p

ress

ures

400

psi

and

hig

her.

e17

-4

PH

st

ems

are

furn

ishe

d

for

serv

ice

tem

per

atur

esex

ceed

ing

600°

F.fIn

cone

l sp

ring

s ar

e fu

rnis

hed

fo

r se

rvic

e p

ress

ures

exce

edin

g 40

0 p

si a

nd/o

r te

mp

erat

ures

exc

eed

ing

600°

F.

hS

tand

ard

sp

ring

(HP

) re

qui

res

min

imum

30

PS

I d

iffer

entia

l. 50

P

SI

is

reco

m-

men

ded

min

imum

diff

eren

tial.

Use

opt

iona

lLo

w∆P

(L

P)

mai

n sp

ring

for

15

psi

min

imum

d

iffer

entia

l. 10

p

si

min

imum

diff

eren

tial

is a

ttai

nab

le b

y ad

din

g b

ase

byp

ass

and

1 ⁄16"

ble

edp

ort.

SIZ

ES

, BO

DY

MA

TE

RIA

LaA

ND

FA

CIN

GS

OT

HE

R M

AT

ER

IALS

a

CAST

IRON

CAST

CAST

STE

ELSE

AT R

INGS

DISC

ST

YP

ES

Flan

ged

Flan

ged

BRON

ZEFl

ange

dFl

ange

dFl

ange

dDi

aphr

agm

Stea

mW

ater

, Oil,

Stea

mW

ater

, Oil,

Stem

Main

Scre

wed

ANSI

ANSI

Scre

wed

Scre

wed

ANSI

ANSI

ANSI

Serv

iceAi

r or G

asSe

rvice

Air o

r Gas

Sprin

gEn

ds12

525

0En

dsEn

ds15

030

060

0Se

rvice

Serv

ice

SIZ

ES

–IN

CH

ES

3 /8-2

1-12

1-12

3 /8-2

3 /8-2

1-12

1-12

1 /2-8

EM

ax. I

nitia

l Pre

ssur

e–ps

i25

012

525

025

030

015

030

060

0S

tain

less

316/

316/

304/

Sta

inle

ssC

arbo

nM

ax. I

nitia

l Tem

pera

ture

–°F

450

450

450

400

750

500

750

750

Ste

el42

0d42

042

0H

ycar

Ste

el o

ror

Min

. Diff

eren

tialc –

psih

10/3

0/50

10/3

0/50

10/3

0/50

10/3

0/50

10/3

0/50

10/3

0/50

10/3

0/50

3017

-4P

He

Inco

nelf

SIZ

ES

–IN

CH

ES

3 /4-2

1-12

—3 /4

-2—

——

E2

Max

. In

itial

Pre

ssur

e–p

si15

15—

15—

——

—30

4/S

tain

less

Car

bon

Max

. In

itial

Tem

per

atur

e–°F

250

250

—25

0—

——

—H

ycar

316

—42

0—

Ste

elS

teel

Min

. D

iffer

entia

lc –p

si3

3—

3—

——

SIZ

ES

–IN

CH

ES

3 /4-2

1-12

1-12

3 /4-2

3 /4-2

1-12

1-12

E5

Max

. In

itial

Pre

ssur

e–p

si25

012

525

025

030

015

030

0—

316/

316/

304/

304/

Sta

inle

ssC

arb

onM

ax.

Initi

al T

emp

erat

ure–

°F45

045

045

040

060

050

060

0—

Hyc

ar42

042

042

042

0S

teel

Ste

el

Min

. D

iffer

entia

lc –p

si5

55

55

55

SIZ

ES

–IN

CH

ES

3 /4-2

1-12

3 /4-2

——

——

E6

Max

. In

itial

Pre

ssur

e–p

si25

012

525

025

0—

——

—31

6/S

tain

less

Car

bon

Max

. In

itial

Tem

per

atur

e–°F

200

200

200

200

——

——

Hyc

ar—

420

—H

ycar

Ste

elS

teel

Min

. D

iffer

entia

lc –p

si10

1010

10—

——

SIZ

ES

–IN

CH

ES

1-2

2-6

2-6

——

——

C34

Max

. In

itial

Pre

ssur

e–p

si20

016

520

0—

——

——

303/

Sta

inle

ssC

arb

onM

ax.

Initi

al T

emp

erat

ure–

°F20

020

020

0—

——

——

Hyc

ar—

304

—H

ycar

Ste

elS

teel

Min

. D

iffer

entia

lc –p

si10

1010

——

——

Page 9: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

COMBINATIONREGULATORS

Page 10: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

TYPE ED PRESSURE REGULATOR

DIMENSIONSinches (mm)

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 53/8 13/8(20) (136) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152 (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(60) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

TYPE ED SERIESPRESSURE

REGULATORCAST IRON, BRONZE or STEEL

for PRESSURES to 600 PSIG at 750°F

APPLICATION DATA

● Pressure Regulating for Steam Distribution

● Single Point or Multiple use Applications

● Pressure Control for Steam Plants

● District Heating Systems

● Single Stage Reductions

● Two Stage Reductions

● Parallel Reduction

G

F

Valve is tapped so thatPilot may be mountedon either side.

VALVE INFO

PILOT INFO

OPERATION

Page 11: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

TYPE E2D PRESSURE REGULATOR

DIMENSIONSinches (mm)

SIZE F G3/4 55/8 13/8

(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 73/8 31/2(100) (187) (89)

5 81/8 31/2(125) (206) (89)

6 81/2 4(150) (216) (102)

8 93/8 61/4(200) (238) (159)

10 11 6(250) (279) (152)

12 117/8 71/4(300) (302) (184)

TYPE E2D SERIESPRESSURE

REGULATORCAST IRON or BRONZE

for PRESSURES to 15 PSIG max.

APPLICATION DATA

● Pressure Regulating for Steam Distribution

● Single Point or Multiple use Applications

● Single Stage Reduction

● Parallel Reduction

● Low Pressure Drop to Operate Valve

● Instantaneous Hot Water Heaters with lowsupply pressures (with the addition of a T14Pilot)

F

G

Valve is tapped so that Pilotmay be mounted on eitherside.

NO. 5B OPEN ELBOW

VALVE INFO

PILOT INFO

OPERATION

Page 12: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

TYPE ED INTEGRAL MOUNT PRESSURE REGULATOR

DIMENSIONSinches (mm)

SIZE F G*3/8 51/4 153/4

(10) (133) (400)

1/2 51/4 153/4(15) (133) (400)

3/4 53/8 17(20) (136) (432)

1 51/2 181/2(25) (140) (470)

11/4 53/4 181/2(32) (146) (470)

11/2 6 191/2(40) (152) (495)

2 61/2 205/8(50) (165) (524)

21/2 7 213/4(65) (178) (552)

3 73/8 231/2(80) (187) (597)

4 87/8 271/4(100) (225) (692)

5 10 285/8(125) (254) (727)

6 113/8 311/2(150) (289) (800)

8 123/4 353/8(200) (324) (899)

10 151/2 433/4(250) (394) (1111)

12 18 473/4(300) (457) (1213)

TYPE ED & ED2INTEGRAL MOUND

PRESSURE REGULATORCAST IRON, BRONZE or STEEL

for PRESSURES to 600 PSIG at 750°F

APPLICATION DATA

● Pressure Regulation for Steam Distributionwhere space is limited

F

F

G

G*

* For D2 Pilot, add 51/4"(133) to this dimension.

VALVE INFO

PILOT INFO

OPERATION

Page 13: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

Bleedport Bend

No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2

No. 4A Bleedport

Serial No. Plate

Do notinsulatebelowthis line

Main ValveType E or E2

ControlPipe

PilotType A85

No. 8B Tee

SerialNo. Plate

RestrictionBend

1/4" Union

F

G

TYPE EA SERIESPRESSURE REGULATOR

TYPE EA SERIESPRESSURE REGULATOR

CAST IRON, BRONZE or STEEL for PRESSURES to 600 PSIG at 750°F

APPLICATION DATA

● Pressure Regulating for Steam Distribution

● Single Point or Multiple use Applications

● Pressure Control for Steam Plants

● District Heating Systems

● Single Stage Reductions

● Two Stage Reductions

● Parallel Reduction

● Control from Remote Location

● Temperature Regulating (with addition of T60Series Pneumatic Temperature Pilot)

Valve is tapped so thatPilot may be mountedon either side.

DIMENSIONSinches (mm)

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 55/8 13/8(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

VALVE INFO

PILOT INFO

Page 14: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

PilotType T14

Thermostat

Bleedport Bend

No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2

No. 4A Bleedport

Serial No. Plate

Do not insulatebelow this line

Main ValveType E or E2

Adjusting Spring

AdjustingWheel

No. 8BTee

SerialNo. Plate

RestrictionBend

1/4" Union

TYPE ET14 TEMPERATURE REGULATOR

TYPE ET14TEMPERATURE

REGULATORCAST IRON, BRONZE or STEEL

CONTROLS 20 to 500°F

APPLICATION DATA

● Temperature Regulation for Batch Process

● Storage Heaters (Water, Fuel Oil or Chemical)

● Air Heating

F

G

Valve is tapped so thatPilot may be mountedon either side.

DIMENSIONSinches (mm)

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 55/8 13/8(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

VALVE INFO

PILOT INFO

Page 15: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

F 6"

TYPE ET14D TEMPERATURE & PRESSURE REGULATOR

TYPE ET14DPRESSURE LIMITING

TEMPERATUREREGULATOR

CAST IRON, BRONZE or STEEL FORCONTROLS 20 to 500°F

APPLICATION DATA

● Temperature & Pressure Regulation for largevolume Heat Exchangers

● Storage Heaters

● Jacketed Kettles

● Vats

G

Valve is tapped so thatPilot may be mounted oneither side.

DIMENSIONSinches (mm)

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 55/8 13/8(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

Pilot Type T14

PilotType D

Adjusting Nuts

AdjustingSpring

Thermostat

Bleedport Bend

No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2

No. 4A Bleedport Serial No. Plate

Do not insulatebelow this line

Main ValveType E or E2

Adjusting SpringHand-wheel

No.8BTee

SerialNo. Plate

RestrictionBend

1/4"Union

1/4"Union

1/4"Control

Pipe

VALVE INFO

D PILOT INFO

T14 PILOT INFO

Page 16: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

TYPE ET124 TEMPERATURE &PRESSURE REGULATOR

DIMENSIONSinches (mm)

SIZE FG

E E23/8 53/8 11/4 —

(10) (136) (32) —

1/2 53/8 11/4 —

(15) (136) (32) —

3/4 55/8 13/8 13/8(20) (143) (35) (35)

1 53/4 11/2 11/2(25) (146) (38) (38)

11/4 6 17/8 17/8(32) (152) (48) (48)

11/2 61/4 2 2(40) (159) (51) (51)

2 65/8 21/8 21/8(50) (168) (54) (54)

21/2 63/4 23/8 23/8(65) (171) (60) (60)

3 71/4 23/4 23/4(80) (184) (70) (70)

4 8 31/2 31/2(100) (203) (89) (89)

5 9 31/2 31/2(125) (229) (89) (89)

6 97/8 4 4(150) (251) (102) (102)

8 101/2 61/4 61/4(200) (267) (159) (159)

10 121/2 6 6(250) (318) (152) (152)

12 14 81/2 71/4(300) (356) (216) (184)

TYPE ET124/ET134 &E2T134 TEMPERATURE &PRESSURE REGULATOR

CAST IRON or STEEL

APPLICATION DATA

● Instantaneous Heaters ● Process Heaters

● Jacketed Kettles ● Vats

● Storage Heaters ● Driers

● Oil Heaters ● Ovens

● Batch Heating

MODELS

● ET124 for heater operating pressures between 20 and 125 psi.

● ET134 for heater operating pressures up to 20 psi.

● E2T134 for heater operating pressures up to 15 psi.

F

G

Valve is tapped so thatPilot may be mountedon either side.

E VALVE INFO

E2 VALVE INFO

PILOT INFO

OPERATION

Page 17: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

DIMENSIONSinches (mm)

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 55/8 13/8(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(654) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

TYPE ED210 REGULATOR

TYPE ED210REGULATOR

ELECTRONIC MODULATION

DELIVERY PRESSURES to 150 PSIG

APPLICATION DATA

● Main Valve adapted to 4-20 mA Signal

● Requires balanced Main Valve

F

G

Valve is tapped so thatPilot may be mounted oneither side.

VALVE INFO

PILOT INFO

Page 18: SECTION I REGULATORS - Steam SpecialtyContents. Pages showing popular combinations of Pilot and Regulators are found in the Combination Regulators Chapter. Detailed product information

SIZE F G3/8 53/8 11/4

(10) (136) (32)

1/2 53/8 11/4(15) (136) (32)

3/4 55/8 13/8(20) (143) (35)

1 53/4 11/2(25) (146) (38)

11/4 6 17/8(32) (152) (48)

11/2 61/4 2(40) (159) (51)

2 65/8 21/8(50) (168) (54)

21/2 63/4 23/8(65) (171) (60)

3 71/4 23/4(80) (184) (70)

4 8 31/2(100) (203) (89)

5 9 31/2(125) (229) (89)

6 97/8 4(150) (251) (102)

8 101/2 61/4(200) (267) (159)

10 121/2 6(250) (318) (152)

12 14 81/2(300) (356) (216)

TYPE ED208D PRESSURE REGULATOR

DIMENSIONSinches (mm)

TYPE ED208DPRESSURE

REGULATORELECTRONIC STARTUP

PILOT OPERATEDDELIVERY PRESSURES to 150 PSIG

APPLICATION DATA

● Electronic Control of Slow Startup and/orSlow Shutdown of Pressure Regulation

● Building Heating Systems

● Can save more than 4 times it’s cost inbuilding heating in one year.

● Requires balanced Main Valve

F 61/2"(165)

G

Valve is tapped so thatPilot may be mounted oneither side.

VALVE INFO

D PILOT INFO

D208 PILOTINFO