section i regulators - steam specialtycontents. pages showing popular combinations of pilot and...
TRANSCRIPT
SECTION IREGULATORS
Iron HorseED SeriesPressure
RegulatorPressures To 600 PSIGTemperatures to 750°F
Three Pilot Mounting Optionsinclude standard side mount (shown),
integral mount and remote mount
SECO Metal Seats and Discsresist wiredraw - not one case
of SECO Metal being cut by steam in 75 years
Packless Constructioneliminates leakage and greatly reduces friction
and stem wear
Two Main Spring Options
for superior regulation over a wide range
of applications
Large, Protected Metal Diaphragm
bathed in condensate, sealed away from steam
seldom needs replacement
No Closely Fitted Partsto stick or bind due to
uneven expansion or foreign matter
Few Moving Partsmean long service life
Applications● Pressure Regulation for Steam Distribution
● Single Point or Multiple Use Applications
● Pressure Control for Steam Plants
● District Heating Systems
● Single Stage Reduction Stations
● Two Stage Reduction Stations
● Parallel Reduction Stations
Springs Outside Steam Pathassure exceptionally long life on both Main Valve and Pilot
Easy Inspectionprovided by external diaphragm loading steam passages
GuaranteedDead End Shutoff meets Class IV in steamservice, even on large sizes
Patented SECOWELD Optionallows easy repair of seat ringthreads damaged by highpressure applications
HOW TO CHOOSE A REGULATORIf you already know the product that you want information on, find the product page in the Table ofContents. Pages showing popular combinations of Pilot and Regulators are found in the CombinationRegulators Chapter. Detailed product information on materials, ratings, dimensions, weights and applica-tions are found in the Products Chapters. All sizing information is contained in the Regulator Sizing Chapter.
If you are not sure of what you need, collect all the following information. You will need it to select the rightproduct for your needs.
Inlet Pressure
Flow Rate
Flow Media (i.e.: Steam, Water, etc.)
Desired Delivery Pressure
Noise Restrictions, if any
Type of Pilot Control (i.e.: Self Contained, Pneumatic, Electronic, etc.)
Application (i.e.: Temperature Regulation, Single Stage Pressure Regulation, etc.)
Application data is listed on each Product Page. If you identify the nature of the installation, it will assistyou selecting the proper equipment.
DIRECT ACTING OR PILOT OPERATED REGULATOR?You may be able to use a Direct Operated Regulator for your application. They are generally less expen-sive than Pilot Operated Regulators. However, they do not provide the same level of accuracy or rangeability.
If a Direct Acting Regulator is an option, consult the Direct Operated Valves Chapter to determine whichbest fits your specific needs. Then, consult the appropriate pages in the Regulator Sizing Chapter toselect the exact size you need.
If a Pilot Operated Regulator is required, go to Page __ (for Pressure Regulators) or Page __ (forTemperature Regulators). These selection charts will help you to quickly determine the type of productthat you need. The Pilot can be self contained, pneumatically or electronically actuated. Consult theappropriate pages in the Regulator Sizing Chapter to select the exact size Regulator and Pilot you need.Overall dimensions of the most popular combinations are provided in the Combination Regulators Chapter.
ECONOMICAL, ENGINEERED OR ENGINEERED WITH NOISE SUPPRESSION?The choice of how to size a regulator for an application is up to you. The most economical choice doesnot necessarily take into consideration the optimum loading of the Regulator, which could affect it’sservice life. Properly engineered Spence Regulators have been in continuous service for as much as 50years. In high pressure reduction stations, noise can be a serious environmental problem. Spence offersa number of Noise Suppression products to reduce this problem. You will find comprehensive noisereduction sizing and selection information in the Noise Reduction Chapter.
THE OPERATING CYCLE OF A SPENCE PRESSURE REGULATORThe basic Type ED has been selected to illustrate the operation of a SPENCE Pilot Operated Pressure Regulator.This presentation describes the successive steps in the mechanical cycle of the Regulator.
1MAIN VALVE is normally closed.On placing Regulator in service,
initial pressure fills the passagesshown in red.
3CONTROL LINE connectsPilot Diaphragm Chamber
to Delivery piping.
4ADJUSTING SPRING,when compressed,
forces Pilot Valve open.
5CONNECTING TUBINGconducts fluid from Pilot
to Main Valve Diaphragmand Bleedport. When Pilotopens, fluid flows throughPilot faster than it canescape at Bleedport, creatinga loading pressure (orange)which forces Main Valveopen.
6DELIVERY PIPE and Control Lineare now being filled with fluid
flowing through Main Valve.As delivery pressure (yellow) rises,
it overcomes the force exerted byAdjusting Spring and Pilot throttles.This , in turn, allows Main Valve tothrottle just enough to maintain theset delivery pressure.
If the demand ceases, Pilot closes,allowing the Main Valve to close –effecting a DEAD-END SHUTOFF.
2PILOT receivesinitial pressure
through Nipple andUnion Connection.
KEY
HIGH PRESSURE
MEDIUM PRESSURE
LOW PRESSURE
THE OPERATING CYCLE OF A SPENCE TEMPERATURE REGULATORThe Type ET134 has been selected to illustrate the operation of a SPENCE Pilot Operated Temperature Regulator.This presentation describes the successive steps in the mechanical cycle of the Regulator.
1MAIN VALVE is normally closed. On placingRegulator in service, initial pressure fills the
passages shown in red.
3CONTROL LINE connects Pilot DiaphragmChamber to Delivery piping.
4PRESSURE SPRINGforces Pilot Valve open.
5CONNECTING TUBING conducts steam fromPilot to Main Valve Diaphragm and Bleedport.
When Pilot opens, steam flows through Pilot fasterthan it can escape at Bleedport, creating a loadingpressure (orange) which forces Main Valve open.
6HEATER, Delivery Pipe and ControlLine are now being filled with steam
flowing through Main Valve.As delivery pressure (yellow) rises, it
overcomes the force exerted by PressureSpring and Pilot throttles. This, in turnallows Main Valve to throttle just enoughto maintain the set delivery pressure.
7THERMOSTAT ELEMENT (vapor tension type) is connected into heater outlet.The rising temperature of the fluid (blue) being heated creates a vapor pressure
(green) on the Temperature Diaphragm. When this pressure has reached a pointsufficient to overcome the Temperature Adjusting Spring, it applies a force on theLever so as gradually to decrease the spring loading on the Pressure Diaphragm.This produces a stem-by-step reduction in the delivery pressure as the temperaturerises through several degrees.
If the desired temperature is exceeded, the vapor pressure on the PilotTemperature Diaphragm overcomes the forces of the Spring. This allows Pilot andMain Valve to close tight.
2PILOT receivesinitial pressure
through Nipple andUnion Connection.
KEY
INITIAL STEAM PRESSURE
LOADING STEAM PRESSURE
DELIVERY STEAM PRESSURE
VAPOR PRESSURE
FLUID HEATED
QUICK SELECTION CHARTFOR STEAM PRESSURE REGULATORS
Review the application data that you have collected. Consult the chart, starting with the inlet pressure that matches the inletpressure you have. Next, select your outlet pressure (reduced or delivery pressure). Then select the type of pilot control that youwill be using and, finally, the level of accuracy that your system requires. This will lead you to a recommended regulator. Please bear in mind that these recommendations are general in nature and you should check the Product Pages and Sizing Sectionto ensure you have selected the correct product. If you need assistance, contact your local Spence Technical Sales Representative.
TYPE ED5
TYPE EA84
TYPE ED210ELECTRONIC*
PNEUMATIC
SELFACTUATED
INITIALPRESSURE
REDUCEDPRESSURE
SPENCEREGULATOR
TYPE OFCONTROL
NORMALREGULATIONACCURACY
± 1/2 PSIG1 PSIG
TO25 PSIG
TYPE ED
TYPE EA43
TYPE ED210ELECTRONIC*
PNEUMATIC
SELFACTUATED
± 1 PSIG3 PSIG
TO150 PSIG
TYPE ED2
TYPE EA70
TYPE ED210ELECTRONIC*
PNEUMATIC
SELFACTUATED
± 2 PSIGABOVE150 PSIG
15 PSIGOR
BELOW
TYPE E2D
TYPE E2A84
TYPE E2D210ELECTRONIC*
PNEUMATIC
SELFACTUATED
± 1 PSIG
TYPE E2D5
TYPE E2A84
TYPE E2D210ELECTRONIC*
PNEUMATIC
SELFACTUATED
± 1/2 PSIG
ABOVE15 PSIG
1 PSIGTO
12 PSIG
* Electronic Pilot accuracy is a function of controller accuracy.
QUICK SELECTION CHARTFOR TEMPERATURE REGULATORS
Review the application data that you have collected. Consult the chart, starting with the inlet pressure that matches the inletpressure you have. Next, select your outlet pressure (reduced or delivery pressure). Then select the type of pilot control that youwill be using and, finally, the level of accuracy that your system requires. This will lead you to a recommended regulator. Please bear in mind that these recommendations are general in nature and you should check the Product Pages and Sizing Sectionto ensure you have selected the correct product. If you need assistance, contact your local Spence Technical Sales Representative.
* See Control Valve Section
TYPEET14
TYPEET14D
TYPEET134
TYPEET124
TYPEEAT61
TYPEE2T14
TYPEJT61*
TYPEE2T14D
TYPEE2AT61
STORAGE ORINSTANTANEOUS
STORAGE ORINSTANTANEOUS
STORAGE ORINSTANTANEOUS
STORAGE ORINSTANTANEOUS
STORAGE ORINSTANTANEOUS
STORAGE ORINSTANTANEOUS
STORAGE
INSTANTANEOUS20 PSI MAXIMUM
INSTANTANEOUS125 PSI MAXIMUM
INLETPRESSURE
OUTLETPRESSURE
SPENCEREGULATOR
HEATERTYPE
TYPE OFCONTROL
SELFCONTAINED
SELFCONTAINED
PNEUMATIC
PNEUMATIC
PNEUMATIC
SELFCONTAINED
SELFCONTAINED
NO PRESSUREREDUCTION
NO PRESSUREREDUCTION
REDUCEDPRESSURE
REDUCEDPRESSURE
15 PSIGOR
BELOW
ABOVE15 PSIG
SPEN
CE
MA
INVA
LVE
SPEC
IFIC
ATIO
NTA
BLE
aM
ain
Valv
es fo
r cor
rosi
ve fl
uid
s or
cos
tly g
ases
req
uire
sp
ecia
l mat
eria
ls.
bB
ronz
e b
ody
and
blin
d f
lang
e on
ly.
cM
inim
um D
iffer
entia
l is
the
sm
alle
st p
erm
issi
ble
diff
eren
ce b
etw
een
initi
al
pre
ssur
e (m
easu
red
at
th
e in
let)
and
th
e d
eliv
ery
pre
ssur
e(m
easu
red
at
the
outle
t) of
the
mai
n va
lve.
dS
ecow
eld
sea
t con
stru
ctio
n d
escr
ibed
in O
ptio
ns S
ectio
n is
regu
larly
furn
ishe
d fo
r se
rvic
e p
ress
ures
400
psi
and
hig
her.
e17
-4
PH
st
ems
are
furn
ishe
d
for
serv
ice
tem
per
atur
esex
ceed
ing
600°
F.fIn
cone
l sp
ring
s ar
e fu
rnis
hed
fo
r se
rvic
e p
ress
ures
exce
edin
g 40
0 p
si a
nd/o
r te
mp
erat
ures
exc
eed
ing
600°
F.
hS
tand
ard
sp
ring
(HP
) re
qui
res
min
imum
30
PS
I d
iffer
entia
l. 50
P
SI
is
reco
m-
men
ded
min
imum
diff
eren
tial.
Use
opt
iona
lLo
w∆P
(L
P)
mai
n sp
ring
for
15
psi
min
imum
d
iffer
entia
l. 10
p
si
min
imum
diff
eren
tial
is a
ttai
nab
le b
y ad
din
g b
ase
byp
ass
and
1 ⁄16"
ble
edp
ort.
SIZ
ES
, BO
DY
MA
TE
RIA
LaA
ND
FA
CIN
GS
OT
HE
R M
AT
ER
IALS
a
CAST
IRON
CAST
CAST
STE
ELSE
AT R
INGS
DISC
ST
YP
ES
Flan
ged
Flan
ged
BRON
ZEFl
ange
dFl
ange
dFl
ange
dDi
aphr
agm
Stea
mW
ater
, Oil,
Stea
mW
ater
, Oil,
Stem
Main
Scre
wed
ANSI
ANSI
Scre
wed
Scre
wed
ANSI
ANSI
ANSI
Serv
iceAi
r or G
asSe
rvice
Air o
r Gas
Sprin
gEn
ds12
525
0En
dsEn
ds15
030
060
0Se
rvice
Serv
ice
SIZ
ES
–IN
CH
ES
3 /8-2
1-12
1-12
3 /8-2
3 /8-2
1-12
1-12
1 /2-8
EM
ax. I
nitia
l Pre
ssur
e–ps
i25
012
525
025
030
015
030
060
0S
tain
less
316/
316/
304/
Sta
inle
ssC
arbo
nM
ax. I
nitia
l Tem
pera
ture
–°F
450
450
450
400
750
500
750
750
Ste
el42
0d42
042
0H
ycar
Ste
el o
ror
Min
. Diff
eren
tialc –
psih
10/3
0/50
10/3
0/50
10/3
0/50
10/3
0/50
10/3
0/50
10/3
0/50
10/3
0/50
3017
-4P
He
Inco
nelf
SIZ
ES
–IN
CH
ES
3 /4-2
1-12
—3 /4
-2—
——
—
E2
Max
. In
itial
Pre
ssur
e–p
si15
15—
15—
——
—30
4/S
tain
less
Car
bon
Max
. In
itial
Tem
per
atur
e–°F
250
250
—25
0—
——
—H
ycar
316
—42
0—
Ste
elS
teel
Min
. D
iffer
entia
lc –p
si3
3—
3—
——
—
SIZ
ES
–IN
CH
ES
3 /4-2
1-12
1-12
3 /4-2
3 /4-2
1-12
1-12
—
E5
Max
. In
itial
Pre
ssur
e–p
si25
012
525
025
030
015
030
0—
316/
316/
304/
304/
Sta
inle
ssC
arb
onM
ax.
Initi
al T
emp
erat
ure–
°F45
045
045
040
060
050
060
0—
Hyc
ar42
042
042
042
0S
teel
Ste
el
Min
. D
iffer
entia
lc –p
si5
55
55
55
—
SIZ
ES
–IN
CH
ES
3 /4-2
1-12
3 /4-2
——
——
—
E6
Max
. In
itial
Pre
ssur
e–p
si25
012
525
025
0—
——
—31
6/S
tain
less
Car
bon
Max
. In
itial
Tem
per
atur
e–°F
200
200
200
200
——
——
Hyc
ar—
420
—H
ycar
Ste
elS
teel
Min
. D
iffer
entia
lc –p
si10
1010
10—
——
—
SIZ
ES
–IN
CH
ES
1-2
2-6
2-6
——
——
—
C34
Max
. In
itial
Pre
ssur
e–p
si20
016
520
0—
——
——
303/
Sta
inle
ssC
arb
onM
ax.
Initi
al T
emp
erat
ure–
°F20
020
020
0—
——
——
Hyc
ar—
304
—H
ycar
Ste
elS
teel
Min
. D
iffer
entia
lc –p
si10
1010
——
——
—
COMBINATIONREGULATORS
TYPE ED PRESSURE REGULATOR
DIMENSIONSinches (mm)
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 53/8 13/8(20) (136) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152 (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(60) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
TYPE ED SERIESPRESSURE
REGULATORCAST IRON, BRONZE or STEEL
for PRESSURES to 600 PSIG at 750°F
APPLICATION DATA
● Pressure Regulating for Steam Distribution
● Single Point or Multiple use Applications
● Pressure Control for Steam Plants
● District Heating Systems
● Single Stage Reductions
● Two Stage Reductions
● Parallel Reduction
G
F
Valve is tapped so thatPilot may be mountedon either side.
VALVE INFO
PILOT INFO
OPERATION
TYPE E2D PRESSURE REGULATOR
DIMENSIONSinches (mm)
SIZE F G3/4 55/8 13/8
(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 73/8 31/2(100) (187) (89)
5 81/8 31/2(125) (206) (89)
6 81/2 4(150) (216) (102)
8 93/8 61/4(200) (238) (159)
10 11 6(250) (279) (152)
12 117/8 71/4(300) (302) (184)
TYPE E2D SERIESPRESSURE
REGULATORCAST IRON or BRONZE
for PRESSURES to 15 PSIG max.
APPLICATION DATA
● Pressure Regulating for Steam Distribution
● Single Point or Multiple use Applications
● Single Stage Reduction
● Parallel Reduction
● Low Pressure Drop to Operate Valve
● Instantaneous Hot Water Heaters with lowsupply pressures (with the addition of a T14Pilot)
F
G
Valve is tapped so that Pilotmay be mounted on eitherside.
NO. 5B OPEN ELBOW
VALVE INFO
PILOT INFO
OPERATION
TYPE ED INTEGRAL MOUNT PRESSURE REGULATOR
DIMENSIONSinches (mm)
SIZE F G*3/8 51/4 153/4
(10) (133) (400)
1/2 51/4 153/4(15) (133) (400)
3/4 53/8 17(20) (136) (432)
1 51/2 181/2(25) (140) (470)
11/4 53/4 181/2(32) (146) (470)
11/2 6 191/2(40) (152) (495)
2 61/2 205/8(50) (165) (524)
21/2 7 213/4(65) (178) (552)
3 73/8 231/2(80) (187) (597)
4 87/8 271/4(100) (225) (692)
5 10 285/8(125) (254) (727)
6 113/8 311/2(150) (289) (800)
8 123/4 353/8(200) (324) (899)
10 151/2 433/4(250) (394) (1111)
12 18 473/4(300) (457) (1213)
TYPE ED & ED2INTEGRAL MOUND
PRESSURE REGULATORCAST IRON, BRONZE or STEEL
for PRESSURES to 600 PSIG at 750°F
APPLICATION DATA
● Pressure Regulation for Steam Distributionwhere space is limited
F
F
G
G*
* For D2 Pilot, add 51/4"(133) to this dimension.
VALVE INFO
PILOT INFO
OPERATION
Bleedport Bend
No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2
No. 4A Bleedport
Serial No. Plate
Do notinsulatebelowthis line
Main ValveType E or E2
ControlPipe
PilotType A85
No. 8B Tee
SerialNo. Plate
RestrictionBend
1/4" Union
F
G
TYPE EA SERIESPRESSURE REGULATOR
TYPE EA SERIESPRESSURE REGULATOR
CAST IRON, BRONZE or STEEL for PRESSURES to 600 PSIG at 750°F
APPLICATION DATA
● Pressure Regulating for Steam Distribution
● Single Point or Multiple use Applications
● Pressure Control for Steam Plants
● District Heating Systems
● Single Stage Reductions
● Two Stage Reductions
● Parallel Reduction
● Control from Remote Location
● Temperature Regulating (with addition of T60Series Pneumatic Temperature Pilot)
Valve is tapped so thatPilot may be mountedon either side.
DIMENSIONSinches (mm)
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 55/8 13/8(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
VALVE INFO
PILOT INFO
PilotType T14
Thermostat
Bleedport Bend
No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2
No. 4A Bleedport
Serial No. Plate
Do not insulatebelow this line
Main ValveType E or E2
Adjusting Spring
AdjustingWheel
No. 8BTee
SerialNo. Plate
RestrictionBend
1/4" Union
TYPE ET14 TEMPERATURE REGULATOR
TYPE ET14TEMPERATURE
REGULATORCAST IRON, BRONZE or STEEL
CONTROLS 20 to 500°F
APPLICATION DATA
● Temperature Regulation for Batch Process
● Storage Heaters (Water, Fuel Oil or Chemical)
● Air Heating
F
G
Valve is tapped so thatPilot may be mountedon either side.
DIMENSIONSinches (mm)
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 55/8 13/8(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
VALVE INFO
PILOT INFO
F 6"
TYPE ET14D TEMPERATURE & PRESSURE REGULATOR
TYPE ET14DPRESSURE LIMITING
TEMPERATUREREGULATOR
CAST IRON, BRONZE or STEEL FORCONTROLS 20 to 500°F
APPLICATION DATA
● Temperature & Pressure Regulation for largevolume Heat Exchangers
● Storage Heaters
● Jacketed Kettles
● Vats
G
Valve is tapped so thatPilot may be mounted oneither side.
DIMENSIONSinches (mm)
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 55/8 13/8(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
Pilot Type T14
PilotType D
Adjusting Nuts
AdjustingSpring
Thermostat
Bleedport Bend
No. 5A Restriction Elbow—Type ENo. 5B Open Elbow—Type E2
No. 4A Bleedport Serial No. Plate
Do not insulatebelow this line
Main ValveType E or E2
Adjusting SpringHand-wheel
No.8BTee
SerialNo. Plate
RestrictionBend
1/4"Union
1/4"Union
1/4"Control
Pipe
VALVE INFO
D PILOT INFO
T14 PILOT INFO
TYPE ET124 TEMPERATURE &PRESSURE REGULATOR
DIMENSIONSinches (mm)
SIZE FG
E E23/8 53/8 11/4 —
(10) (136) (32) —
1/2 53/8 11/4 —
(15) (136) (32) —
3/4 55/8 13/8 13/8(20) (143) (35) (35)
1 53/4 11/2 11/2(25) (146) (38) (38)
11/4 6 17/8 17/8(32) (152) (48) (48)
11/2 61/4 2 2(40) (159) (51) (51)
2 65/8 21/8 21/8(50) (168) (54) (54)
21/2 63/4 23/8 23/8(65) (171) (60) (60)
3 71/4 23/4 23/4(80) (184) (70) (70)
4 8 31/2 31/2(100) (203) (89) (89)
5 9 31/2 31/2(125) (229) (89) (89)
6 97/8 4 4(150) (251) (102) (102)
8 101/2 61/4 61/4(200) (267) (159) (159)
10 121/2 6 6(250) (318) (152) (152)
12 14 81/2 71/4(300) (356) (216) (184)
TYPE ET124/ET134 &E2T134 TEMPERATURE &PRESSURE REGULATOR
CAST IRON or STEEL
APPLICATION DATA
● Instantaneous Heaters ● Process Heaters
● Jacketed Kettles ● Vats
● Storage Heaters ● Driers
● Oil Heaters ● Ovens
● Batch Heating
MODELS
● ET124 for heater operating pressures between 20 and 125 psi.
● ET134 for heater operating pressures up to 20 psi.
● E2T134 for heater operating pressures up to 15 psi.
F
G
Valve is tapped so thatPilot may be mountedon either side.
E VALVE INFO
E2 VALVE INFO
PILOT INFO
OPERATION
DIMENSIONSinches (mm)
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 55/8 13/8(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(654) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
TYPE ED210 REGULATOR
TYPE ED210REGULATOR
ELECTRONIC MODULATION
DELIVERY PRESSURES to 150 PSIG
APPLICATION DATA
● Main Valve adapted to 4-20 mA Signal
● Requires balanced Main Valve
F
G
Valve is tapped so thatPilot may be mounted oneither side.
VALVE INFO
PILOT INFO
SIZE F G3/8 53/8 11/4
(10) (136) (32)
1/2 53/8 11/4(15) (136) (32)
3/4 55/8 13/8(20) (143) (35)
1 53/4 11/2(25) (146) (38)
11/4 6 17/8(32) (152) (48)
11/2 61/4 2(40) (159) (51)
2 65/8 21/8(50) (168) (54)
21/2 63/4 23/8(65) (171) (60)
3 71/4 23/4(80) (184) (70)
4 8 31/2(100) (203) (89)
5 9 31/2(125) (229) (89)
6 97/8 4(150) (251) (102)
8 101/2 61/4(200) (267) (159)
10 121/2 6(250) (318) (152)
12 14 81/2(300) (356) (216)
TYPE ED208D PRESSURE REGULATOR
DIMENSIONSinches (mm)
TYPE ED208DPRESSURE
REGULATORELECTRONIC STARTUP
PILOT OPERATEDDELIVERY PRESSURES to 150 PSIG
APPLICATION DATA
● Electronic Control of Slow Startup and/orSlow Shutdown of Pressure Regulation
● Building Heating Systems
● Can save more than 4 times it’s cost inbuilding heating in one year.
● Requires balanced Main Valve
F 61/2"(165)
G
Valve is tapped so thatPilot may be mounted oneither side.
VALVE INFO
D PILOT INFO
D208 PILOTINFO