TM 11-5855-217-12-1 TECHNICAL MANUAL OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS SEARCHLIGHT SET, NSN NSN INFRARED AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10. The title was changed to read as shown above by C7. HEADQUARTERS, DEPARTMENT OF THE ARMY 2 JULY 1970

Upload: others

Post on 23-Jan-2021

16 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

TECHNICAL MANUAL

OPERATOR’S AND ORGANIZATIONALMAINTENANCE MANUAL

INCLUDING REPAIR PARTS AND SPECIAL TOOL LISTS

SEARCHLIGHT SET,

NSNNSN

INFRAREDAN/VSS-3A

5855-00-177-35295855-00-405-0404

This copy is a reprint which includes current

pages from Changes 1 through 10. The title

was changed to read as shown above by C7.

HEADQUARTERS, DEPARTMENT OF THE ARMY2 JULY 1970

Page 2: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1C 10

CHANGE

No. 10

HEADQUARTERSDEPARTMENT OF THE ARMYWASHINGTON, DC ,31 March 1981

Operator’s and Organizational Maintenance Manualincluding Repair Parts and Special Tools ListsSEARCHLIGHT SET, INFRARED AN/VSS-3A

(NSN 5855-00-177-3529) (NSN 5855-00-405-0404)

TM 11-5855-217-12-1, 2 July 1970, is changed as follows:

1. New or changed material is indicated by a vertical bar in the margin.2. Remove old pages and insert new pages as indicated below.

Remove page Insert page1-1 and 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..1.1 and 1-2

3. File this change sheet in front of the publication for reference purposes.

By Order of the Secretary of the Army:

Official:

E. C. MEYERGeneral, United States Army

Chief of Staff

J. C. PENNINGTONMajor General, United States Army

The Adjutant General

DISTRIBUTION:Active Army:

HISA (Ft Monmouth) (21) USAES (2)USAINSCOM (2) USAICS (3)COE (1) MAAG (1)TSG (1) USARMIS (1)USAARENBD (1) USAERDAA (1)DARCOM (1) USAERDAW (1)TRADOC (2) Ft Carson (5)OS MAJ COMD (4) Ft Gillem (10)TECOM (2) Ft Gordon (10)USACC (4) Ft Richardson (CERCOM Ofc) (2)MDW (1) Army Dep (1) exceptArmies (2) SAAD (30)Corps (2) SHAD (2)Svc Colleges (1) TOAD (14)USASIGS (5) USA Dep (1)USAADS (2) Sig Sec USA Dep (1)USAFAS (2) Units org under fol TOE:USAARMS (2) 29-207 (2)USASIS (2) 29-610 (2)

NG: State AG (3) Units — SAME AS ACTIVE ARMY EXCEPT ALLOWANCE IS ONE COPY PER UNIT.USAR: NoneFor explanation of abbreviations used, see AR 310-50.

Page 3: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

WARNING

Do not direct searchlight at personnel closer than 320 meters or permanent eyedamage can be inflicted. Do not look into the searchlight beam in either thevisible or infrared modes. Even momentary viewing can produce permanent eyedamage if closer than 320 meters and staring can be harmful up to 3,000 meters.temporary flash blindness may occur at ranges exceeding 3,000 meters.Do not look into the searchlight beam with magnifying optical elements such asbinoculars.Dangerous voltages are present in the searchlight at the following locations:

Xenon lamp electrodes 30,000 voltsIgniter transformer 30,000 voltsSpark gap 6,000 voltsInterstage transformer 6,000 voltsConverter transformer 100 voltsCapacitors C1, C2, and C3 100 volts

Do not operate the searchlight if the blower motor does not run, or turn off thevehicle power source until the blower motor stops. The blower motor cools theXenon lamp to prevent explosion and injuries.Do not touch the quartz envelope of the Xenon lamp with bare hands. Dirt andfinger acids can erode the quartz envelope, and the lamp may explode duringoperation due to the weakened envelope.Exercise extreme caution when handling the high-pressure Xenon lamp.Always transport and handle the lamp in the lampholder, and avoid jarring orshocking the lampholder. During installation of this equipment, conform to allsafety requirements set forth in TB SIG 291. Injury or DEATH can result fromfailure to comply with safe practices.Installation of the searchlight is a two-man operation. Failure to use two men toinstall the searchlight could result in dropping or severe jarring of thesearchlight, with subsequent damage to the equipment, or possible seriousinjury or DEATH to personnel.Installation of the control box is a two-man operation. Failure to use two mento install the control box could result in serious injury to personnel.Make sure the vehicle power source supplying power to the searchlight set isturned off before performing the interunit cabling procedure.Turn the searchlight power switch OFF if OVER TEMP indicator lights.Continued operation of the searchlight when high temperature is indicated cancause Xenon lamp explosion, resulting in damage to the searchlight andpossible serious injury to personnel.

Change 7

Page 4: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

TECHNICAL MANUAL HEADQUARTERSDEPARTMENT OF THE ARMY

No. 11-5855-217-12-1 WASHINGTON , D. C., 2 July 1970

Operator and OrganizationalMaintenance Manual

Including Repair Parts and Special Tool Lists

SEARCHLIGHT SET, lNFRARED/AN/VSS-3AFSN 5855-177-3529FSN 5855-405-0404

Paragraph Page

CHAPTER 1.Section I.

II.

CHAPTER 2.Section I.

II.

CHAPTER 3.Section I.

II.III.

CHAPTER 4.Section I.

II.III.

CHAPTER 5.Section I.

II.III.

CHAPTER 6.

Section I.II.

APPENDIx A.

B.

C.D.

E.

INDEX . . . .

OPERATOR'S MAINTENANCEGeneral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator's preventive maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator's maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-1,4-24-3—4-54-6—4-8

4 -14 - 1

4-2,4-3

5 -1 ,5 -25-3—5-55-6—5-17

5 -15-1,5-25-3—5-7.1

F i g u r e

1-11-22-12-22-33-13-1.13-24-15-15-2

INTRODUCTIONDescription and data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1—1-3General-------------------------------------------------------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - 1-4—1-10

INSTALLATIONService upon receipt of equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1,2-2Installation procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-3—2-10

OPERATING INSTRUCTIONSOperators controls and indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1—3-3Operation under usual conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4—3-10Operation under unusal conditions . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11—3-15

1-11-1—1-3

2-12-3-2-5

3-1,3-23-2—3-43-4,3-5

ORGANIZATIONAL MAINTENANCEGeneral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Organizational preventive maintenance . . . . . . . . . . . . . . . . . . .Organizational troubleshooting and repairs . . . . . . . . . . . . . . . . . . . . . . .

SHIPMENT, LIMITED STORAGE, AND DEMOLITION TO PREVENTENEMY USE

Dissassembly and repackaging of equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1—6-3 6-1Demolition to prevent enemy use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4-6-7 6-1,6-2

REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1

BASIC ISSUE ITEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1MAINTENANCE ALLOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1

ORGANIZATIONAL REPAIR PARTS, FOR FSN 5855-177-3529 . . . . . . . . . . . . . . . . . . . . . . . . . D-1

ORGANIZATIONAL REPAIR PARTS, FOR FSN 5855-405-0404 . . . . . . . . . . . . . . . . . . . . . . . .E-1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I - 1

LIST OF ILLUSTRATIONS

Title

Searchlight Set, Infrared AN/VSS-3A, FSN 5855-177-3529 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Searchlight Set, Infrared AN/VSS-3A, FSN 5855-405-0404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

2-2Packing of Searchlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outline and mounting dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interunit cabling diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control box, Controls and indicators (C-7905A/VSS-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control, Searchlight Set C-7905B/VSS-3, Controls and Indicators . . . . . . . . . . . . . . . . . . . .Remote Control Box, Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat Exchanger, RearView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replacement of Indicator Lamps and Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replacement of Front Window and Xenon Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ii

2-42-53-53-53-64-35-55-6

Change 7 i

Page 5: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

1. CANVAS COVER2. CONTROL, SEARCHLIGHT SET C-7905A/VSS-33. CONTROL, SEARCHLIGHT SET C-7906A/VSS-34 EXTRACTOR ASSEMBLY5. SEARCHLIGHT, INFRARED MX-8272A/VSS-3

EL5855-217-12-1-C7-TM-I

Figure 1-1. Searchlight Set, Infrared AN/VSS-3A, FSN 5855-177-3529.

ii Change 7

Page 6: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

1. CANVAS COVER2. CONTROL, SEARCHLIGHT SET C-7905B/VSS-33. CONTROL, SEARCHLIGHT SET C-7906B/VSS-34. EXTRACTOR ASSEMBLY5. SEARCHLIGHT, INFRARED MX-8272B/VSS-3

EL5855-217-12-1-C7-TM-1.1

Figure 1-2. Searchlight Set, Infrared AN/VSS-3A, FSN 585-405-0404.

Change 7 iii / (iv blank)

Page 7: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CHAPTER 1INTRODUCTION

Section I. GENERAL

1-1. Scope

a. This manual describes Searchlight Set, In-frared AN/VSS-3A NSN 5855-00-177-3529 or 5855-00-405-0404 and covers its installation and opera-tion, and operator and organizational mainte-nance. It includes operation under usual andunusual conditions, cleaning and inspection of theequipment, and replacement of parts available tooperator and organizational maintenance person-nel.

b. Appendix A contains a list of publicationsapplicable to the equipment, appendix B containsthe basic issue items list, appendix C contains themaintenance allocation chart, and appendices Dand E contain the organizational repair parts.

NOTEAppendices B, C, D, and E are current asof 25 June 1975.

c. Official nomenclature followed by (*) is used toindicate all models of equipment.

1-2. Indexes of Publications

a. DA Pam 310-4. Refer to the latest issue of DAPam 310-4 to determine whether there are neweditions, changes, or additional publications per-taining to the equipment.

b. DA Pam 310-7. Refer to DA Pam 310-7 todetermine whether there are modification workorders (MWO’s) pertaining to the equipment.

1-3. Forms and Records

a. Reports of Maintenance and UnsatisfactoryEquipment. Maintenance forms, records, and re-ports which are to be used by maintenancepersonnel at all maintenance levels are listed inand prescribed by TM 38-750.

b. Report of Packaging and Handling Deficien-cies. Fill out and forward SF 364 (Report ofDiscrepancy (ROD) as prescribed in AR 735-11-2/DLAR 4140.55/NAVMATINST 4355.73/AFR400-54 and MCO 4430.3E.

c. Discrepancy in Shipment Report (D ISREP)(SF 361). Fill out and forward Discrepancy inShipment Report (DISREP) (SF 361) as prescribedin AR 55-38/NAVSUPINST 4610.33B/AFR 75-18/MCO P461O.19C, and DSAR 4500.15.

1-3.1. Reporting of Equipment PublicationImprovements

The reporting of errors, omissions, and recom-mendations for improving this publication by theindividual user is encouraged. Reports should besubmitted on DA Form 2028 (RecommendedChanges to Publications and Blank Forms) andforward directly to Commander, US Army Elec-tronics Command, ATTN: DRSEL-MA-Q, FortMonmouth, NJ 07703.

1-3.2. Reporting Equipment ImprovementRecommendations (EIR)

EIR’s will be prepared using DA Form 2407(Maintenance Request). Instructions for prepar-ing EIR’s are provided in TM 38-750, The ArmyMaintenance Management System. EIR’s shouldbe mailed direct to Commander, US Army Elec-tronics Command, ATTN: DRSEL-MA-Q, FortMonmouth, NJ 07703. A reply will be furnisheddirect to you.

1-3.3. Hand Receipt

Hand receipts for End Item/Components of EndItem (COEI), Basic Issue Items (BII), and Addi-tional Authorized List (AAL) items are publishedin a Hand Receipt Manual. The Hand ReceiptManual numerical designation is the same as therelated Technical Manual with the letters HRadded to the number. These manuals are publishedto aid in property accountability y and are availablethrough: Commander, US Army Adjutant GeneralPublication Center, ATTN: AGDL-OD, 1655 Wood-son Road, St. Louis, MO 63114.

Section II. DESCRIPTION AND DATA

1-4. Purpose and Use 1-5. Technical CharacteristicsThe AN/VSS-3A is a lightweight, Xenon sear- Type of light . . . . . . . . . . . . . . Visible or infrared

chlight providing a high intensity variable beam Type of lamp . . . . . . . . . . . . . Xenon, short arc, 1.0 kilowatt

width, visible or infrared light. It is a watertight, Output candlepower . . . ...50 million minimum

weather resistant, vehicle monted searchlight Beam width:Compact . . . . . . . . . . . . ..1.0°±0.5°

used to illuminate battlefield and other tactical Variable . . . . . . . . . . . . ..1.0° to 7.0°areas during nighttime operations.

Change 10 1-1

Page 8: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1Input power requirements:

Voltage . . . . . . . . . . . . . . . 22 to 28 vdc (24 to 28(MX-8272B/VSS-3)

Current . . . . . . . . . . . . ..58 amperes maximumPower . . . . . . . . . . . . . ...1.6 kilowatts minimum

Mode of operation:

Infrared light . . . . . . . . . Compact, spread or variable beamvdc for width.

Cooling system . . . . . . . . . . . Air-to-air heat exchanger usingintegral intake exhaust blower.

Reflective system . . . . . . . . . Metal parabolic mirrorFocus-defocus method . . . . . Motor driven

Visible light . . . . . . . . . . Compact, spread or variable beam Searchlight control . . . . . . . Provided by control box and remote width. control box.

1-6. Items Comprising an Operable Searchlight Set, Infrared AN/VSS-3A, NSN 5855-00-177-3529

N S N

Weight

I T E M Quantity (lb)

5855-00-177-3528 Searchlight, Infrared MX-8272A/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 625855-00-177-3525 Control, Searchlight Set C-7905A/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 ½5855-00-177-3527 Control, Searchlight Set C-7906A/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 ½

1-6.1. Items Comprising an Operable Searchlight Set, Infrared AN/VSS3A, NSN 5855-00-405-0404

N S N

Weight

I T E M Quantity (lb)

5855-00-189-6066 Searchlight, Infrared MX-8272B/VSS~3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 62

5855-00-189-6065 Control, Searchlight Set C-7905B/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 ½5855-00-451-5224 Control. Searchlight Set C-7906/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 ½

Note. The items comprising AN/VSS-3A, NSN 5855-00-177-3529 are interchangeable with items comprising AN/VSS-3A, NSN5855-00-405-0404.

1-6.2. Installation Kits

The following installation kits must be requisitioned separatelya. Installation Kit M551.

N S N I T E M Quantity

5855-00-114-4949 Installation Kit, M551 consisting of. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

5855-00-135-0162 Searchlight support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

5810-00-767-9425 Flat washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45305-00-716-8186 Cap screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45855-00-110-3541 Quick disconnect pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35996-00-135-0081 Cable Assembly, Power, Electrical CX-11893/VSS-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15305-00-052-6456 Screw cap, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45310-00-721-7809 Washer, lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45305-00-269-2803 Screw, cap, hexagon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45310-00-061-1258 Washer, lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

b. Installation Kit M60.N S N I T E M Quantity

5855-00-114-4953 Installation kit, M60 consisting of . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15855-00-1144954 Searchlight mount assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15310-00-767-9425 Flat washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45305-00-725-4183 Cap screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45995-00-177-3562 Cable Assembly, Power, Electrial (SC-D-647380) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15310-00-004-5033 Washer, lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45305-00-269-3209 Screw cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45310-00-891-1749 Nut, hex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45305-00-995-3444 Screw, pan head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45310-00-045-3296 Washer, lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45310-00-809-8546 Washer, flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1-2 Change 10

Page 9: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

1-7. Common Names Common name Nomenclature

A list of common name assignments for compo- Power cable . . . . . . . . . . . . . . Cable, Assembly, Power, Electrical

nents of searchlight set is given below CX-11893/VSS-3

Common name Nomenclature Beam switch . . . . . . . . . . . . COMPACT-SPREAD BEAM switch

Control box . . . . . . . . . . . . . . . Control Searchlight Set C-7905 Control Switch . . . . . . . . . . . . LOCAL-REMOTE switch(*)/VSS-3

Remote control box . . . . . . . Control, searchlight set C-7906(*)/VSS-3

Change 10 1-2.1

Page 10: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

Common name NomenclaturePower switch . . . . . . . . . . . . . O F F - I N F R A R E D - V I S I B L E

switchSearchlight . . . . . . . . . . . . . . Searchlight, Infrared MX-

8272(*)/VSS-3Searchlight set . . . . . . . . . . . Searchlight Set, Infrared

AN/VSS-3AC a n v a s c o v e r . . . . . . . . . . Searchlight cover

1-8. Description of Equipment(fig. 1-1, 1-2)

CAUTIONThe components of this searchlight arenot compatible with any other equip-ment except that which is covered inthis manual. If a VSS-3 searchlight sub-assembly is connected to a VSS-3A con-trol box, the booster-starter module willburn out. If a VSS-3A searchlight subas-sembly is connected to a VSS-3 controlbox, the searchlight will not operate butno damage will occur.

Searchlight Set, Infrared AN/VSS-3A consists ofthree major components. The three componentsare the searchlight, the control box, and the re-mote control box. Mounting hardware is part ofthe installation kit (para 1-6.2).

a. Searchlight, Infrared MX-8272(*)/VSS-3. Thisunit contains the greater part of the searchlightset components and protects the internal compo-nents from physical damage and exposure to dustand moisture. The searchlight consists of the mainsupport assembly, searchlight housing, heat ex-changer, window, and window clamp. Thesearchlight is attached to the searchlight supportby means of mounting hardware.

(1) Searchlight main support assemb!y. Thisassembly consists of the main support assembly,reflector, Xenon lamp, IR filter, diode CR 1, trans-formers, spark gap assembly, terminal board TB1,filter drive motor, focus-defocus motor, elapsedtime indicator and shock mounts. Low voltages (28volts dc) from the vehicle power source is convertedto a high voltage (30 kv) for ignition of the Xenonlamp. After the lamp is ignited, the 28 volts dc isused to maintain lamp illumination. The light pro-duced by the Xenon lamp is concentrated andshaped by the reflector. Mechanical controls areused to position the IR filter over the Xenon lampfor IR illumination.

(2) Searchlight housing. The searchlight hous-ing is a pressed aluminum shell fitted with carry-ing handles, latches, and an electrical receptacle.The housing contains the searchlight main sup-port assembly which is attached to it by shockmounts.

(3) Heat exchanger. The heat exchanger is at-

TM 11-5855-217-12-1tached to the rear of the searchlight housing andelectrically connected to the main support assem-bly. This unit contains the blower motor, with in-take and exhaust fans, ballast resistor, and therear cover to which air ducts and cooling fins areattached.

(4) Window and window clamp. The window issealed and attached to the searchlight housing bythe window seal and window (grooved) clamp. Thewindow provides protection against dust and mois-ture.

b. Control, Searchlight Set C-7905(*)/VSS-3. Thecontrol box contains the necessary switches andindicators for operating, monitoring operation,and troubleshooting the searchlight. It is mountedwithin the tank and consists of a housing and amounting plate.

(1) The housing contains the control, power,and beam switches used to control searchlight op-eration, the CIRCUIT TEST switch and indicatorused for troubleshooting, and the OVER TEMPand LAMP ON indicators used to monitorsearchlight operation. Also, the housing containsreceptacles for power and intercomponent connec-tions.

(2) The mounting plate attached to the housingis used to mount the control box within the vehicle.

c. Control, Searchlight Set C-7906(*)/VSS-3. Theremote control box contains the necessaryswitches and indicators for operating and monitor-ing the operation of the searchlight from the re-mote position. It is mounted within the vehicle andconsists of a housing and a mounting plate.

(1) The housing contains the control, power,and beam switches used to control the operation ofthe searchlight. Also, the housing contains theOVER TEMP and LAMP ON indicators and a re-ceptacle for connection to the control box.

(2) The mounting plate attached to the panelhousing is used to mount the remote control boxwithin the vehicle.

1-9. Description of Minor Components(fig. 1-1, 1-2)

Accessories included in the searchlight set are theextracter assembly and the searchlight cover. Thesearchlight cover is a canvas cover used to protectthe searchlight when the equipment is not in oper-ation. The portion which covers the window con-tains a stiffener to protect the glass. The extractorassembly is used when removing the Xenon lamp.

1-10. Additional Equipment Required

The following equipment is not supplied as a partof the searchlight set, but is required for its opera-tion:

Change 8 1-3

Page 11: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1Equipment Purpose

Source of 28vdc, 58 amperes Supply dc power to theminimum. searchlight.

DC input power cable (sup Connect external power toplied by vehicular mainte- the control box.nance).

Equipment PurposeSearchlight power cable Connects the control box to

(supplied by vehicular the vehicle receptacle.maintenance).

Remote control box cable Connects the remote control(supplied by vehicular box to the control box.maintenance).

1-4 Change 8

Page 12: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CHAPTER 2

INSTALLATION

WARNING

During installation of this equipment, conform to all safety requirements set forth inTB SIG 291. Injury or DEATH can result from failure to comply with safe practices.

Section I. SERVICE UPON RECEIPT OF EQUIPMENT

2-1. Unpacking(fig. 2-1 )

a. Packaging Data. When packed for shipment,Searchlight Set, Infrared AN/VSS-3A is packedin a wooden shipping container divided into twocompartments, One compartment contains thesearchlight, and the other compartment contains abox holding the remainder of the searchlight setcomponents.

WARNINGRemoving the searchlight is a two-manoperation. Failure to use two men to re-move the searchlight could result indropping the searchlight, with subse-quent possible damage to the equipmentor injury to personnel.

CAUTIONUse care in removing the lid of the ship-ping container and the searchlight setcomponents to avoid damaging them.

b. Removing Contents. Pry off the top of theshipping container with a crowbar or similar tool.Remove the packing material and lift out thesearchlight. Remove the box containing the re-mainder of the searchlight set components.

2-2. Checking Unpacked Equipmenta. Inspect the searchlight set for damage that

may have occurred during shipment. If the equip-ment has been damaged, report the damage onDD Form 6 (para 1-3).

b. Check to see that the searchlight set is com-plete as listed on the packing slip. If a packingslip is not available, check the equipment againstparagraph 1-6 or 1-6.1. Report all dis-

crepancies in accordance with TM 38-750. Theequipment should be placed in service even thougha minor assembly or part that does not affectproper functioning is missing.

c. Check to see whether the equipment has beenmodified. If the equipment has been modified, theMWO number will appear on the front panelnear the nomenclature plate, Check also to seewhether all MWO’s current at the time the equip-ment has been placed in use have been applied.Refer to DA Pam 310-7.

NOTE

Current MWO’s applicable to the equip-ment are listed in DA Pam 310-7.d. Check the latest issue of DA Pam 310-4

(never more than 1 year old) and its latestchanges (never more than 6 months old) to seewhether you have the latest editions of all applica-ble maintenance literature. Equipment issued bydepots may have been in stock for some time andmay contain superseded manuals.

NOTE

Included in the packing case isTM 11-5855-217-12-2 (envelope) contain-ing caution decals and installation in-structions. Decals should be aplied

as soon as the Searchlight and ControlBox are mounted.

Change 9 2-1

Page 13: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure 2-1. Packing of Searchlight.

2-2 Change 7

Page 14: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

NOTE

TM 11-5855-217-12-1Section II. lNSTALLATION PROCEDURES

The following assembly and installation procedures must be made by organizationalsupport, or higher level maintenance personnel.

2-3. Tools, Test Equipment, and MaterialsRequired for Installation

No test equipment or materials are required forinstallation of the searchlight set. The followingtools are required for installation.

Item Purpose

Toolkit, TK 100G.. . . . . . . . . . . . . . . . . Installation of searchlight

2-4. Assembly of Component Items

(fig. 2-2)WARNING

The Xenon lamp is filled with gas underhigh pressure. Be extremely careful inhandling the searchlight. Jarring or se-vere shocks could cause the lamp toexplode, resulting in damage to theequipment, and possible serious injury orDEATH to personnel.

CAUTIONPrior to first time installation of asearchlight on a vehicle, check the polar-ity of the input power. Input power con-nections must be +28 volts dc on pin A ofthe input power cable and common at pinB.

a. The searchlight set is installed on a platformon Armored Reconnaissance/Airborne AssaultVehicle M551, Installation Kit M551 is required forinstalling the searchlight set on the M551.

b. The searchlight set is installed on the gunturret of Tank, Combat, Full Tracked M60. Instal-lation Kit M60 is required for installing thesearchlight on the M60.

c. Make sure that you have the proper installa-tion kit as described in paragraph 1-6.2.2-5. Installation of Searchlight on M551

WARNINGThe Xenon lamp is filled with gas underhigh pressure. Be extremely careful inhandling the searchlight. Jarring or se-vere shocks could cause the lamp toexplode, resulting in damage to theequipment, and possible serious injury orDEATH to personnel.

To attach the support to the searchlight, performthe following procedures:

a. Set the searchlight down with the front of thesearchlight pointing in the vertical direction.

b. Align the four holes in the support (fig. E-3)with the four mounting holes in the bottom of thehousing.

c. Put a washer and mounting screw in eachmounting hole and tighten each screw loosely.

d. Align the support with the searchlight and

tighten the screws.e. The searchlight is installed on the mounting

platform using the three quick-release pins in theinstallation kit. To install the searchlight, performthe following procedures:

(1) Lower the searchlight onto the mountingplatform and insert the two rear legs of the supportinto the mounting platform ears.

(2) Align the holes in the support with the holesin the mounting platform and insert, but do nottighten, two quick-release pins.

(3) Lower the front of the searchlight until thehole in the front leg of the support is aligned withthe hole in the front of the mounting platform.

(4) Insert a quick-release pin.(5) Tighten all three pins.

2-5.1. Installation of Searchlight on M60(fig. 2-2,2-3, and E-4)

WARNINGInstallation of the searchlight is a two-man operation. Failure to use two men toinstall the searchlight could result indropping or severe jarring of thesearchlight, with subsequent damage tothe equipment or possible injury orDEATH to personnel.

a. Align the four holes in M60 mount assemblywith four mounting holes in bottom of searchlight.

b. Use four washer and cap screws to securesearchlight to M60 mount assembly.

c. With ball latches unlocked, lift searchlight andposition searchlight ball sockets on three ball studson gun shield.

d. Lock ball latches by depressing hitch handles.2-6. Installation of Control Box

(fig. 2-2)

WARNINGInstallation of the control box is a two-man operation. Failure to use two men toinstall the control box could result in seri-ous injury to personnel.

To install the Control Box, perform the followingprocedures:

a. Position the control box mounting plate overthe four control box mounting holes in the vehicle.

b. Put a lockwasher over each of four screws.c. Insert a screw in each mounting hole and

tighten.2-7. Installation of Remote Control Box

(fig. 2-2)Use the following procedures in installing the re-mote control box:

Change 8 2-3

Page 15: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure 2-2. Outline and mounting dimensions.

a. Position the mounting holes in the remotecontrol box mounting plate over the four mountingholes in the vehicle.

b. Put a lockwasher over each of the four mount-ing screws.

c. Insert a mounting screw in each hole andtighten.

2-8. Interunit Cabling(fig. 2-3)

WARNINGMake sure that the power source applyingpower to the searchlight set is turned offbefore performing the interunit cablingprocedure.

Perform interunit cabling of the searchlight in thefollowing order:

a. Power cable (1) from searchlight to vehiclereceptacle.

b. Power cable (2) from vehicle receptacle to con-trol box.

c. Remote control box cable (3) from remote con-trol box J 1 to control box J2.

d. Input power cable (4) from vehicle powersource to J 1 on control box.

2-9. Initial Checks and Adjustments

Perform the following checks and adjustments be-fore operating the searchlight set.

2-4 Change 8

Page 16: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure 2-3. Interunit cabling diagram.

a. Check that the Xenon lamp is installed.b. Set the CIRCUIT TEST switch on the

trol box to the OPERATING POSITION.con-

C. Set the power switches on both the controlbox and the remote control box to OFF.

d. Set the control switch on the control box toLOCAL.

e. Check that proper MOTOR and auxiliary B +fuses are installed in the control box. See para-graph 6-8 for fuse ratings.

f. Check all mounting screws for tightness.

g. Check all cable connections for tightness andproper fit.

h. Check that interunit cabling is proper andcomplete.

j. Check air intake and exhaust ducts (fig 4-1)to be sure they are clear and free of obstructions.

2-10. ServicingPerform the operator’s preventive maintenancechecks and services (para 4-4). When the testsare completed, report the equipment ready for operation.

Change 9 2-5

Page 17: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1C2

CHAPTER 3

OPERATING INSTRUCTIONS

Section I. OPERATORS CONTROLS AND INDICATORS

WARNINGBefore operating this equipment, make sure that all requirements of TB SIG 291 aremet, Injury or DEATH could result from improper or careless operation.

3-1. Searchlight Controls(figs. 3-1 and 3-2)

Control

COMPACT BEAM-SPREAD BEAM(beam switch).

OFF-INFRARED-VISIBLE(power switch).

Function

COMPACT BEAM (down) position—searchlightproduces a narrow light beam.

SPREAD BEAM (up) position (springloaded)spreads beam from 1.0O compact to full spreadat 7.0°. Approximately 2 seconds is required forfull beam expansion. To hold beam at any widthbetween two extremes, release beam switch andallow it to return to center position.

NOTECenter position is off position for focusmotor. Holds beam width fixed whilebeam switch is at SPREAD BEAM.

OFF (down) position—turns off power to setand returns searchlight to infrared mode.

INFRARED (middle) position—places search-light in infrared operating mode.

VISIBLE (up) position—places searchlight invisible operating mode.

CIRCUIT TEST switch ______________________ OPERATING POSITION—normal position foroperating searchlight.

Position 2-tests for input voltage level at 22volts dc minimum.

Positon 3-tests B+ to sense board.

Position 4-tests blocking diode CR1 forcontinuity.

Position 5-tests for application of 22 to 28 voltsdc to blower motor.

Position 6-tests lamphouse connector for con-tinuity.

Position 7—tests input voltage and power relayK1 operation.

3-1

Page 18: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Control

LOCAL-REMOTE(control switch).

3–2. Searchlight Indicators(figs. 3-1 and 3-2)

Indicator

OVER TEMP indicator

LAMP ON indicator

CIRCUIT TEST indicator

3–3. Variation of Indicator Lamp BrightnessThe brightness of all indicator lamps is varied

through a grating arrangement in the body of theindicator. To vary lamp brightness, turn the bodyof the lamp as indicated.

3-4. Heat( figs.

Do not

Function

LOCAL position—switches control of searchlightto control box.

REMOTE position—switches control of search- light to remote control box.

Function

Indicates when searchlight is overheated. Turnson at400° F and turns off at380 0 F.

Indicates when searchlight Xenon lamp is on bylighting.

With CIRCUIT TEST switch in OPERATINGPosition, allows normal operation ofthe searchlight.

With CIRCUIT TEST switch in positions 2through 7, indicates malfunction in circuitunder test by not lighting.

a. To dim the lamp, turn the body of the lampclockwise.

b. To brighten the lamp, turn the body of thelamp counterclockwise.

Section II. OPERATION UNDER USUAL CONDITIONS

Exchanger4-1, 5-2)

WARNINGattempt any cleaning procedures

while the searchlight is operating. Thesearchlight uses high voltages and cur-rent for operation which can cause seri-ous injury.

The air intake and exhaust ducts on the heat ex-changer must be free from obstructions before theequipment is operated. If necessary, flush waterthrough air ducts to remove any dirt, insects, orother foreign matter which may restrict air circu-lation.

3-5. Preliminary Control Settings(figs. 3-1 and 3-2)

The searchlight set may be operated in the spread,compact, or variable beam mode of operation. The

3-2 Change 7

preliminary control settings and the starting pro-cedures are the same for all types of operation.Before starting the equipment (para 3–6), checkthe setting of the operating controls as follows:

Control Position

Power switch OFFCIRCUIT TEST

switch . . OPERATING POSITIONControl switch LOCAL

3–6. Starting Procedure(figs. 3-1 and 3–2)

NOTE

If an abnormal result is obtained duringthe starting procedure, refer to the oper-ational checks (para 4- 5, sequence Nos.9 through 11). Refer to paragraph 3–4before starting the equipment.

a. Start the vehicle power source.

Page 19: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

WARNING1. Do not look directly into the searchlightbeam. Blindness or serious eye damage mayresult.2. Do not operate the searchlight in thecompact beam visible mode while personnelare within 320 meters of the beam path.3. Personnel may suffer temporary flashblindness at ranges in excess of 320 meterswhen the searchlight is operated in either thecompact or spread beam visible mode.4. Do not operate the searchlight if theexhaust blower does not operate.

b. Set the power switch to either the INFRAREDor VISIBLE position; depending on the mode ofoperation required. The Xenon lamp will ignitewithin 3 seconds, the exhaust blower will operate,the LAMP ON indicator will light, and the CIR-CUIT TEST indicator does not light.

c. If the Xenon lamp does not ignite, set thepower switch to OFF and repeat the startingprocedure. Do not try to ignite the Xenon lamp afterfive or six attempts have been made.

d. Check the air intake and exhaust ducts (fig. 4-1) for airflow to make certain that the blower motoris operating.

e. After 1 minute of Xenon lamp operation, checkto see that the OVER TEMP indicator is not lighted.Improper cooling of the searchlight will cause theOVER TEMP indicator to light.

CAUTIONPeriodically check the OVER TEMP in-dicator during searchlight operation. Thesearchlight set will continue to operate evenif an overheated condition exists. It is theresponsibility of the operator to turn off thesearchlight set if the OVER TEMP indicatorlights.

3-7. Beam Width Adjustments(figs. 3-1 and 3-2)

To adjust the beam width, start the searchlight setas described in paragraph 3-5, and proceed as. follows:

a. Compact Beam Operation. Place the beamswitch to the COMPACT BEAM position. Thesearchlight beam width will automatically be ad-justed until the narrowest beam width of ap-proximately 1.0° is projected from the searchlight.

b. Spread Beam Operation. Place the beam switchin the SPREAD BEAM position and hold until thewidest beam width (7°) is projected from thesearchlight.

c. Variable Beam Operation. A variable beamwidth is obtained by holding the spring-loaded beamswitch in the SPREAD BEAM (up) position. The

light beam will spread from 1.0° to 7.0° beam widthin 2 seconds. To hold the beam at any width between1.0” and 7.0°, release the beam switch, allowing it toreturn to the center position. The beam will stay atthe desired width until the beam switch is placed ineither the SPREAD BEAM or COMPACT BEAMposition. If the switch is returned to SPREADBEAM position, the searchlight beam will continueto spread to 7.0°. The beam spread maybe stoppedand held any number of times until the beam is fullyspread to 7.0°. To return the beam to 1.00(compact narrow beam), it is necessary to set thebeam switch to the COMPACT BEAM position.3-8. Modes of Operation

(figs. 3-1 and 3-2)a. Visible Mode. Pull out on the power switch

lever, move up to VISIBLE position and release.b. Infrared Mode. Push the power switch lever to

the INFRARED position; the switch will remainlocked.

c. Remote Control. To control the searchlightfrom the remote control box, set the control boxfollows:

Control Position

Power switch O F FCIRCUIT TEST switch OPERATING POSITIONControl switch REMOTE

NOTEIf the control box power switch is at IN-FRARED or VISIBLE, power will be ap-plied to the searchlight regardless of theposition of the control switch on the controlbox .

3.9. Normal Stopping Procedure(figs. 3-1 and 3-2)

CAUTIONDo not turn the searchlight off anywhereexcept at the control box or remote controlbox.

a. Set Control Box C7905A/VSS-3 controlsfollows:

as

as

the

(1) Place the beam switch to COMPACTBEAM and hold for 2 seconds, to release the strainon the reflector.

(2) Set the power switch to OFF.b. Control Box C-7905B/VSS-3, set the power

switch to OFF. A relay will cause the beam toreturn to the compact mode and release the strainon the reflector. The Xenon lamp will turn off;blower motor will continue to operate if thesearchlight has been operating more than 5minutes.

WARNINGTo prevent Xenon lamp explosion andpossible injury to personnel, wait until the

Change 7 3-3

Page 20: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

blower motor stops before continuing with 3-10. Emergency Stopping Procedurethe next procedure. In an emergency, it maybe necessary to turn off the

c. Shut off the vehicle power source. searchlight set in the shortest possible time. To dod. Set all operating controls to the positions this, shut off the vehicle power

specified in paragraph 3-5. power to the searchlight set.

Section Ill. OPERATION UNDER UNUSUAL CONDITIONS

3-11. FordingCAUTION

Do not operate the searchlight when fordingthrough deep water.

a. The searchlight can be forded through deepwater without damaging the searchlight internalcomponents. The window clamp contains a gasketwhich forms a waterproof seal for the window. Theheat exchanger contains a gasket which forms awaterproof seal between the heat exchanger and thesearchlight housing.

b. Check to be sure that gaskets in the windowdamp and heat exchanger are in good condition andthat the clamp and cover latches are properly closed.Water will flow into the heat exchanger through theopen air intake and exhaust ducts without damagingthe searchlight.3-12. Operation in Arctic ClimatesSubzero temperatures and climatic conditionsassociated with the cold weather affect efficient useof the equipment. Instructions and precautions foroperations under such adverse conditions are asfollows.

a. Frequently inspect the exterior of the search-light and remove any accumulations of ice or snow,particularly around the window and the air intakeand exhaust ducts.

b. Inspect the power cable, window clamp, andwindow for possible damage. Report defects tohigher category of maintenance.

c. Cover the searchlight when it is not inoperation.

source that supplies

3-13. Operation in Tropical ClimatesWhen operated in tropical climates, moisture andhumid conditions can cause problems with thesearchlight. These conditions are particularly severewhen the searchlight set is operated in swampyareas. Condensation of moisture on the equipmentoccurs frequently. To minimize the possibility ofdamage by moisture, take the following precautions:

a. Keep the equipment dry and clean.b. Check all exterior parts frequently for evidence

of corrosion and fungus formation.c. Inspect the heat exchanger air intake and

exhaust ducts and remove any obstructions.d. Inspect the heat exchanger and window for a

tight fit.e. Inspect the front panels on the remote control

box and control box for evidence of corrosionfungus formation.

f. Properly tighten all electrical connectors.g. Cover the searchlight when it is not

operation.3-14. Operation in Desert Climates

or

in

Heat and dusty or sandy conditions are primaryproblems in desert areas. To minimize thepossibility of damage by heat, dust, or sand, takethe following precautions:

a. Remove the window or heat exchanger onlywhen absolutely necessary.

b. Cover the searchlight with the canvas coverwhen the searchlight is not in operation. If possi

3-4 Change 7

Page 21: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

F i g u r e box(C-7905A/VSS-3), controls and indicators.3-1. Control

CIRCUIT TEST SWTCH BEAM SWITCH

Figure 3-1.1 Control box(C-7905B/VSS-3), controls and indicators,

Change 9 3-5

Page 22: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

ble, locate the searchlight in a sheltered area.Take advantage of any natural barrier which mayoffer protection from blowing dust.

c. Inspect the heat exchanger air intake andexhaust ducts. Flush the duct openings with waterto remove any obstructions.

d. Keep the equipment clean.

3-15. Operation Under SaltSpray Environments

Water

Instructions and precautions for operation undersalt water spray conditions are as follows:

a. Protect the searchlight from salt waterspray. Wash it down regularly with fresh haterand wipe dry with a clean, lint free cloth.

b. If permanent shelter is not available, protectthe searchlight with the canvas cover when it isnot in operation. Remove the cover during dryperiods and allow the searchlight to dry out.

c. Inspect all painted surfaces for cracked,peeled, or blistered paint, and report discrepan- ties to higher category of maintenance.

Figure 3-2. Remote control box, controls and indicator.

3-6 Change 5

Page 23: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CHAPTER 4

OPERATOR’S MAINTENANCE

Section I. GENERAL

4-1. Scope c. Operator troubleshooting (para 4-8).

The maintenance duties assigned to the operator 4-2. Tools, Test Equipment, andof the searchlight set are listed below together Materials Requiredwith a reference to the paragraphs covering the No tools or teat equipment are required for opera-specific maintenance funtion. tor maintenance. Materials required to clean the

a. Operator weekly preventive maintenance searchlight set are given below.checks and services (para 4-6). a. Soft, clean, lint free cloth.

b. Cleaning (para 4-6). b. Fresh water and mild soap.

Section Il. OPERATOR’S PREVENTIVE MAINTENANCE

4-3. Preventive MaintenancePreventive maintenance is the systematic care,servicing, and inspection of equipment to preventthe occurrence of trouble, to reduce downtime,and to assure that the equipment is serviceable.

a. Systematic Care. The procedures given inparagraphs 4-6 and 4-6 cover routine systematiccare and cleaning essential to the proper upkeepand operation of equipment.

b. Preventive Maintenance Checks and Services.The preventive maintenance checks and serviceschart (para 4-5 ) outlines functions to be per-formed at specific intervals. These checks andservices are to maintain Army electronic equip-ment in a combat-serviceable condition; that ‘s, ingood general (physical ) condition and in good op-erating condition, The chart indicates what tocheck, how to check, and what the normal condi-tions are. The References colums lists the illustra-

4-5. Operator Weekly Preventive MaintenanceSequence

No. Item to be inspected

tions or paragraphs containing detailed checksand services procedures. If an abnormal conditionis found and the defect cannot be remedied by theoperator, higher category of maintenance or re-pair is required. Records and reports of thesechecks must be made in accordance with the re-quirements set forth in TM 38-750.

4-4. Preventive Maintenance Checks andServices Required

Preventive maintenance checks and services ofthe searchlight set are required weekly. Para-graph 4–5 specifies checks and services that mustbe accomplished weekly and under the specialconditions listed below.

a. When the equipment is initially installed.b. When the equipment is reinstalled after re-

moval for any reason.c. At least once each week if the equipment is

maintained in a standby condition.

Checks and Services Chart

Procedures References

1 Exterior surfaces - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C L E A N S E A R C H L I G H T A N D C O N T R O L B O X PANELS Para 4-6I N S P E C T D E C A L S F O R D A M A G E

2 H e a t e x c h a n g e r - - - - - - - - - - - - - C l e a n a i r i n t a k e a n d e x h a u s t d u c t s - - - - -Para 4-6

3 Window - - - - - - - - - - - - - - - - - - - - - - a . Clean window - - - - - - - - - - - - - - - - - - - - - Para 4-6

b. Check glass for deep scratches or cracks.

4 Reflector - - - - - - - - - - - - - - - - - - a. Check for cleanliness.

b. Check surface area for scratches or discoloration.

Change 9 4-1

Page 24: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1Sequence Item to be inspectedNo.

5 Intercabling and connectors

References

6 S e a r c h l i g h t m o u n t7 Searchlight . . .

8 K n o b s a n d s w i t c h e s .

9 Circuit test switch . .

10 Power switch . . .

11 Control switch .

Procedure

. . . . . . Check all interconnecting cables and connectors forcracks and breaks.

. . . Check attaching parts for tight connections.

. . . . . . . . Check for cracks, dents, or other evidence ofdamage.

. . . . . . . While making operational checks (items 9 through12), observe that mechanical action of eachknob and switch is smooth and free ofbinding. Set the following knobs andswitches as indicated, before proceeding tostep 9.

Control switch LOCALPower switch OFF

. . . . . . . Start engine and turn vehicle power switch ON.Set to OPERATING POSITION and turn on

searchlight. Note that CIRCUIT TESTindicator lamp does not light.

. . . . . . . a. Set to VISIBLE: Xenon lamp will ignite within3 seconds, exhaust blower will operate, andLAMP ON indicator will fight. After

approximately 1 minute of Xenon lamp opera-tion, see that OVER TEMP indicator is notlighted.

b. If Xenon lamp does not light within 3 seconds,set to OFF, and repeat procedure. Do notattempt to ignite Xenon lamp after five orsix attempts have been made.

c. During visible mode of operation, adjust forspread beam, and then compact beam. Notethat light beam varies in width.

d. Set to INFRARED. Wait a few seconds, thennote that:

(1) LAMP ON indicator lamp lights ininfrared mode,

(2) Mode of operation changes fromvisible to infrared.

. . . . . . . a. Set to REMOTE, Repeat sequence 10. Notethat remote control box operates the search-light.

b. Set to LOCAL.12 Blower motor . . . . . . . . . . . . . . . . . . Set to VISIBLE. Wait 10 minutes, and then set

to OFF. Heat exchanger blower motor mustcontinue to operate.

13 S e a r c h l i g h t s h u t d o w n . . Follow procedure given in para 3-9 to turn offsearchlight. Turn vehicle power switch OFF,stop the engine.

Section Ill. OPERATOR’S MAINTENANCE

4-6. Cleaning Procedures(fig. 4-1)

WARNINGMake certain that the searchlight set isturned off and cool before cleaning.

a. Exterior surfaces. The exterior should beclean, free of dust, dirt, grease, insects and fungus.

4-2

Do not wash the exterior of the equipmentwith high-pressure hoses.(1) Wash the exterior of the searchlight with a

Change 9

Para 3-6

Para 3-5

Para 3-6

Para 3-7

Para 3-8

Para 3-8

Para 3-8

Para 3-9

(2) If dirt is difficult to remove, use a dampcloth or sponge and mild soap, then flush withfresh water,

(3) When the exterior surface contains onlydust or loose dirt, wipe it with a clean soft cloth.

(4) Remove grease, fungus, and ground-in dirtfrom the equipment by using a cloth and soap andwater. Flush exterior surfaces with low-pressurefresh water. Dry equipment with a clean, lint freecloth.

Page 25: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CAUTIONDo not use any cleaning solvent or abrasivecompound on the glass.

c. Searchlight Window. Clean the outside of thewindow with a clean, lint free cloth and fresh water.Gently wipe from the center to the outer edge, Ifscratched or cracked, refer to organizationalmaintenance.

d. Reflector. If dirty or scratched, refer toorganizational maintenance. I4-7. LubricationNo lubrication of the AN/VSS-3A is required.4-8. Operator’s Troubleshooting Chart

WARNINGDo not operate searchlight while personnelare within 320 meters of the beam path; eyedamage will result. I

a. Troubleshooting of this equipment by theoperator is based upon the results of the operatingchecks sequence numbers 9 through 14 in paragraph4-5.

b. When troubleshooting equipment, follow theoperating checks until a trouble symptom is noted,

Figure 4-1. Heat exchanger, rear view. then turn the CIRCUIT TEST switch to the positionindicated in the Symptom column.

b. Heat Exchanger. Remove foreign matter fromthe heat exchanger air intake and exhaust ducts (fig.4-1 ) by flushing with low-pressure water.Item

No. Symptom1 X e n o n l a m p d o e s n o t i g n i t e ,

blower motor does not operate,CIRCUIT TEST indicator doesnot light in position 6.

2 X e n o n l a m p d o e s n o t i g n i t e ,blower motor does not operate,ClRCUIT TEST indicator doesnot light in position 7. Setpower switch to: VISIBLE.

3 X e n o n l a m p d o e s n o t i g n i t e ,Mower motor operates CIRCUITT E S T i n d i c a t o r l i g h t s i nposition 3 but not in position 4.

4 X e n o n l a m p d o e s n o t i g n i t e ,b l ower motor opera tes , CIR-CUIT TEST indicator does notlight in position 3.

5 X e n o n l a m p d o e s n o t i g n i t e ,b l ower motor opera tes , CIR-CUIT TEST indicator does notlight in position 2.

Probable troublea. Cable not connected between

search light and control box orbad wire in cable.

b. Control switch not in correctposition.

c. CIRCUIT TEST switch not inoperating position.

d. Power contactor bad

a. Control switch not in correctposition.

b. DC power cable not connectedto c o n t r o l b o x o r c a b l edefective.

c. Power contractor defective

a. Broken wire between blockingdiode and power contactor incontrol box.

b. Blocking diode open in search-light.

a. B+ to sense board missing

b. Broken wire in searchlight.

Input voltage level below 22 voltsNote. MX-8272B/VSS-3 lamp may

not ignite if the input voltagelevel is below 24 volts.

Corrective actiona. Refer equipment to organizational

maintenance.

b. M o v e c o n t r o l s w i t c h t o c o r r e c tposition.

C . Move CIRCUIT TEST switch tooperating position.

d. Refer equipment to direct supportmaintenance.

a. M o v e c o n t r o l s w i t c h t o c o r r e c tposition.

b. Refer equipment to organizationalmaintenance.

c. Refer equipment to direct supportmaintenance.

a. Refer equipment to direct supportmaintenance.

b. Refer equipment to direct supportmaintenance.

a. Refer equipment to direct supportmaintenance.

b. Refer equipment to direct supportmaintenance.

Raise input voltage level to withinthe range of 22-28 volts.

Change 7 4-3

Page 26: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

ItemNo.

6

7

8

9

10

11

12

13

14

15

1617

Symptom

X e n o n l a m p d o e s n o t i g n i t e ,b l owcr motor opera tes , CIR-CUIT TEST indicator Iighs inall positions.

Xenon lamp ignites, blower motord o t s n o t o p e r a t e C I R C U I TTEST indicator does not light inposition 5.

Xenon lump ignites, blower motord o e s n o t o p e r a t e . C I R C U I TT E S T i n d i c a t o r I i g h t s i nposition 5.

Xenon lamp ignites, blower motoroperates, beamwidth does notvary. ClRCUIT TEST indicatordoes not light in position 7.

Same as 9 above except ClRCUITT E S T i n d i c a t o r l i g h t s i nposition 7.

Xenon lamp ignites, blower motoro p e r a t e s , s e a r c h l i g h t c a n n o tchange modes of illumination,CIRCUIT TEST indicator doesnot light in position 6.

Same as 11 above except CIR-CUIT TEST indicator lights inposition 6.

Searchlight does not start from remote control box or remote

control box does not controlsearchlight operation.

OVER TEMP indicator lampcomes on during searchlightoperation.

LAMP ON indicator does not lightduring searchlight operation.

Probable trouble

Defective Xenon lamp . . . . . . . .

a. Broken wire in power cable . . .

b. Blower motor relay defective . . .

a. Air intake and exhaust ductsclogged .

b. Blower motor defective . . . . .

a. Auxiliary B+ fuse blown (F1)

b. Broken wire in cable . . . . . . .

c. Broken wire in control box . . .

a. Defective power cable . . . . .

b. Focus motor defective . . . . .

c. Beam switch defective . . . . . .

a. Motor fuse blown (F2) . . . . . . .

b. P o w e r c a b l e t o s e a r c h l i g h tdefective.

c. Reverse po lar i ty p ro te c t i ondiode CR open.

a. C o n t i n u i t y t o f i l t e r m o t o rbroken in searchlight.

b. Filter motor bad . . . . . . . . . . .

a. Control s w i t c h i n wrongposition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

b. Cable from remote control boxto control box defective.

c. Defective switch or broken wirein remote control box.

a. Air intake and exhaust ductsclogged.

b. Continuity t o b l o w e r m o t o rbroken in cable.

c. Blower motor defective . . . .

a. Defective indicator lamp . . . .

b. Broken wire in control box . . . .

DeletedSearchlight l ight output dim or

beam irregular.a. Window dirty . . . . . . . . . . . . . . . . . .

b. Reflector dirty . . . . . . . . . . . . . . . .

c. Front window pitted . . . . . . . . . . . . .

Corrective action

Refer searchlight to organizationalmaintenance for replacement ofXenon lamp (PARA 5-12).

a. Refer equipment to organizationalmaintenance.

b. Refer equipment to direct supportmaintenance.

c. Clean exhaust ducts (pare 4-6b).

b. Refer searchlight to direct supportmaintenance.

a. Refer equipment to organizationalmaintenance,

b. Refer equipment to organizationalmaintenance.

c. Refer equipment to organizationalmaintenance.

a. Refer equipment to organizationalmaintenance.

b. Refer equipment to organizationalmaintenance.

c. Refer equipment to organizationalmaintenance.

a. Refer equipment to organizationalmaintenance.

b. Refer equipment to organizationalmaintenance.

c. Refer equipment to organizationalmaintanance.

a. Refer equipment to organizationalmaintenance.

b. Refer equipment to organizationalmaintenance.

a. Move control switch to correctposition.

b. Refer equipment to organizationalmaintenance.

c. Refer equipment to organizationalmaintenance.

a. CIean air intake and exhaust ducts(para 4-6b).

b. Refer equipment to organizationalmainenance.

c. Refer equipment to organizationalmaintenance.

a. Refer equipment to organizationalmaintenance.

b. Refer equipment to organizationalmaintenance.

a. CIean exterior of window (para 4-6)and/or interior of window (para 5-5).

b. Refer searchlight to organizationalmaintenance.

c. Refer searchlight to organizationalmaintenance.

4-4 Change 9

Page 27: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

No.Item

Symptom Probable trouble Corrective action

18 Searchlight beam too high . . Searchlight out of vertical adjustment R e f e r e q u i p m e n t t o d i r e c t s u p p o r tmaintenance.

19 Searchlight beam defocused . Reflector-lamp focal length incorrect R e f e r s e a r c h l i g h t t o d i r e c t s u p p o r tmaintenance.

4-5

Page 28: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CHAPTER 5

ORGANIZATIONAL MAINTENANCE

Section l. GENERAL

5-1. Scope of Organizational Maintenancea. This chapter contains instructions covering

organizational maintenance of the searchlight set. Itincludes instructions for performing preventive andperiodic maintenance services and repair functions tobe accomplished by the organizational repairman.

b. Organizational maintenance of the searchlightset includes —

(1) Organizational monthly preventivemaintenance checks and services chart (para 5-3).

(2) Painting and refinishing (para 5-4).(3) Organizational cleaning (para 5-5).(4) Organizational troubleshooting (paras 5-6

and 5-7),(5) Repairs (paras 5-8 through 5-16).

5-2. Tools and Materials Required for Organiza-tional Maintenance

a. Lamp and holder assembly.b. Slotted screwdriver.c. Phillip’s-type screwdriver.d. One-half-inch wrench.e. Clean, lint free cloth.f. Soap and water.g. Alcohol.h. Face mask.i. Asbestos gloves.j. Fine sandpaper.k. Paint.l. Protective apron.

Section Il. ORGANIZATIONAL PREVENTIVE MAINTENANCE

Note : REPLACE XENON TUBE AFTER 300 HOURS OF OPERATION.

5-3. Organizational Monthly Preventive Main- required. All deficiencies must be recorded in ac-tenance Checks and Services cordance with requirements of TM 38-750. Perform

Monthly preventive maintenance checks and ser- all the checks and services in the sequence listedvices on Searchlight Set, Infrared AN/VSS-3A are below.

S e q u e n c e

No.1234

Item to be inspectedCompletenessInstallationCleanlinessPreservation

5 Publications

Modifications6

7 Spare parts

8 M o u n t i n g

ProcedureCheck that equipment is completeCheck that equipment is properly installedCheck that equipment is cleanCheck all external and internal surfaces for

evidence of fungus, rust, or corrosion.Remove rear cover to check internalsurfaces.

Check t o see that a l l pub l i ca t i ons arecomplete, sericeable. and current.

Check DA Pam 310-7 to determine if newapplicable, MWO’s have been published.ALL, URGENT MWO's must be appliedimmediately All ROUTINE MWO’s mustbe scheduled.

Check operator and organizational spareparts for general condition and method ofstorrage. There should be no overstockageand a l l shor tages must be on va l idrequisitions.

Check that all exterior bolts are tight

ReferenceParas 1-6, 1-8, 1-9, fig. 1-1.Para 1-6, 1-8, 1-9. fig. 1-1.Paras 4-6 and 5-5.Paras 5-4 and 5-17.

DA Pam 310-4.

TM 38-750 and DA Pam 310-7.

App. D.

Ch. 2.

Change 7 5-1

Page 29: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

SequenceNo. Item to be inspected

9 Power cable

10 Canvas cover

11 Elapsed Time Meter

12 Searchlight

ReferenceProcedure

Inspect for corrosion, stripped threads,damaged insulation, and proper f it toreceptacles.

Inspect for damaged material such as tears fig. 1-1.and broken tie down straps. Replace coverif worn or damaged. Para 5-17

Check for advanced reading Para 5-12Note. The Xenon lamp must be replaced

every 300 hours.Perform operational checks Ch. 3. para 4-5.Warning 1. Do not operate the searchlight

if the blower motor does not operate.Warning 2. Do not look directly into the

searchlight beam in either the visual orinfrared mode of operation. Serious eyedamage may result.

5-4. Repainting and Refinishing InstructionsRemove met and corrosion from metal surfaces bysanding them lightly with fine sandpaper. Brush twothin coats of paint on the bare metal to protect itfrom further corrosion. Refer to applicable cleaningand refinishing practices and materials specified inSB 11-573, TM 9-213, and TB 746-10.5-5. Organizational CleaningRefer to paragraph 4-6 for procedures for cleaningexterior surfaces, heat exchanger and the searchlightwindow exterior. In addition, organizationalmaintenance is responsible for cleaning the reflectorand the interior of the searchlight window.

WARNING1. Make sure that the searchlight has beenturned off for at least 15 minues beforeperforming the following procedures.2. When working around the reflectorassembly, make certain that protectiveclothing, face mask, and gloves are worn.The Xenon lamp is filled with Xenon gasunder high pressure, and may explode ifjarred.

a. Remove the case window (para 5-11).b. Clean inside surface of case window using soap

and water. Rinse away soap and dry case windowwith a clean, lint free cloth.

CAUTION1. The reflector is delicate and easilyscratched. Searchlight performance will beimpaired if reflector surface is scratched. Useextreme caution in cleaning the reflector. Donot use any cleaning solvents or abrasivecompounds.2. Do not leave water on interior of search-light. Possible shorting of components andserious damage to the searchlight couldoccur.

c. Clean the reflector assembly using soap andwater on a dampened cloth. Gently wipe from centerto outer edge. To remove soap film, use a clean dampcloth. Do not use any cleaning solvents or abrasivecompounds on the reflector.

d. Install the case window (para 5-11).

Section Ill. ORGANIZATIONAL TROUBLESHOOTING AND REPAIRS

5-6. GeneralTroubleshooting of this equipment is based on theoperational checks described in paragraph 4-5,sequence Nos. 9 through 14. To troubleshoot theequipment; follow the operational checks until atrouble symptom is found, and then refer to thetroubleshooting chart (para 5-7). Locate the troublesymptom in the chart, isolate the trouble using theCIRCUIT TEST switch and indicator, and performthe indicated corrective action. If the troublesymptom is not listed, refer to higher category ofmaintenance. After performing each corrective5-2 Change 7

action sequence, return to the starting procedure tocheck whether the trouble symptom is still present.If the symptom is still present, refer to highercategory of maintenance.

WARNINGDo not operate searchlight while personnelare within 320 meters of the beam path; eyedamage will result.

NOTECheck to be sure that the CIRCUIT TESTindicator lamp is not defective beforestarting the troubleshooting procedure.

Page 30: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

5-7. Organizational Troubleshooting ChartItem

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Symptom

Xenon lamp does not ignite, blower motordoes not operate, CIRCUIT TEST indica-tor does not light in position 6.

Xenon lamp does not ignite, blower motordoes not operate, CIRCUIT TEST indica-tor does not light in position 7. Set powerswitch to VISIBLE.

Xenon lamp does not ignite, blower motoroperates CIRCUIT TEST indicator lightsin position 3 but not in position 4.

Xenon lamp does not ignite, blower motoroperates, CIRCUIT TEST indicator doesnot light in position 3.

Xenon lamp does not ignite, blower motoroperates, CIRCUIT TEST indicator doesnot light in position 2.

Xenon lamp does not ignite, blower motoroperates, CIRCUIT TEST indicator lightsin all positions.

Xenon lamp ignites, blower motor does notoperate CIRCUIT TEST indicator doesnot light in position 5.

Xenon lamp ignites, blower motor does notoperate, CIRCUIT TEST indicator lightsin position 5.

Xenon lamp ignites, blower motor operates,beamwidth does not vary, CIRCUITTEST indicator does not light in position7.

Same as 9 except CIRCUIT TEST indicatorlights in position 7.

Xenon lamp ignites, blower motor operates,searchlight cannot change modes of il-lumination, CIRCUIT TEST indicatordoes not light in position 6.

Same as 11 except CIRCUIT TEST indicatorlights in position 6.

Searchlight does not start from remote con-trol box or remote control box does notcontrol searchlight operation.

a.

b.c.

d.

a.b.

c.a.

b.

a.

b.

Probable trouble

Cable not connected between searchlightand control box or bad wire in cable.Control switch not in correct position.CIRCUIT TEST switch not in operatingpositionPower contactor bad . . . . . . . . . . . . . . .

Control switch not in correct position.DC power cable not connected to controlbox or cable defective.P o w e r c o n t a c t o r d e f e c t i v e .Broken wire between blocking diode andpower contactor.Blocking diode open in searchlight

B+ to sense board missing . . . . . . . . . . .

B r o k e n w i r e i n s e a r c h l i g h t .

Input voltage level below 22 voltsNote. MX-8272B/VSS-3 may not ignite if theinput voltage level is below 24 volts.Defective Xenon lamp . . . . . . . . . . . . . . .

a.b.

a.b.

a.b.c.

a.

b.c.a.

a.

b.a.b.

c.

OVER TEMP indicator lamp comes on dur- a.ing searchlight operation.

b.

c.

Broken wire in power cable . . . . . . . . . .Blower motor relay defective . . . . . . .

Air intake and exhaust ducts clogged . . .Blower motor defective. . . . . . . . . .

Auxiliary B+ fuse blown (F1) . . . . . . . . .Broken wire in cable . . . . . . . . . . . . . . .B r o k e n w i r e i n c o n t r o l b o x .

Defective power cable . . . . . . . . . . . . . . . .

Focus motor defective . . . . . . . . . . . . . .Beam switch defective . . . . . . . . . . . . . .Motor fuse blown (F2) . . . . . . . . . . . . . . .

Continuity to filter motor broken insearchlight.Filter motor bad... . . . . . . . . . . . . . . . . . .Control switch in wrong position. . . . . .Cable from remote control box to controlbox defective.Defective stitch or broken wire in remotecontrol box.Air intake and exhaust ducts clogged. . .

Continuity or blower motor broken in ca-ble.Blower motor defective, . . . . . . . . . . . .

a.

b.c.

d.

a.b.

c.a.

b.

a.

b.

Corrective action

Connect or replace cable (para 5-10).

Move corntrol switch to correct position.Move CIRCUIT TEST switch to operatingposition.Refer equipment to direct support mainte-nance.Move control switch to correct position.Connect DC power cable or replace defec-tive cable (para 5-10).Replace control box (para 5-15).Refer equipment to direct support mainte-nance.Refer equipment to direct support mainte-nance.Refer equipment to direct support mainte-nance.Refer equipment to direct support mainte-nance.

Raise input voltage level above 22 volts.

Replace Xenon lamp (para 5- 12).Note. If after replacing the xenon lamp thelamp still will not ignite, reinstall the originallamp in the searchlight and refer to highercategory of maintenance.a.b.

a.b.

a.b.c.

a.

b.c.a.

a.

b.a.b.

c.

a.

b.

c.

Replace power cable (para 5-10),Replace control box (para 5-15).

Clean exhaust ducts (para 4-6b).Refer searchlight to direct support mainte-nance.Replace auxiliary B+ fuse (para 5-8).Replace power cable (para 5-10).Replace control box (para 5-15).

Replace power cable (para 5-10).

Replace searchlight (para 5-13).Replace control box (para 5-15).Replace motor fuse (para 5-8).

Replace searchlight (para 5-15).

Replace searchlight (para 5-13).Move contro! switch to correct position.Replace defective cable (para 5-10).

Replace remote control box (para 5-16).

Clean air intake and exhaust ducts (para4-6b).Replace power cable (para 5-10).

Replace searchlight.

Change 9 5-3

Page 31: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

ItemNo.15

16

17

18

19

SymptomLAMP ON indicator does not light

during searchlight operation.

ELAPSED TIME indicator doesnot advance during searchlightoperation.

Searchlight light output dim orbeam irregular.

Searchlight beam too high . . . . . . . . . . .

Searchlight beam defocused . . . . . . . . .

Probable troublea. Defective indicator lamp . . . . . . . . . . . . .

b. Broken wire in control box . . . . . . . . . . .Defective meter

a. Window dirty . . . . . . . . . . . . . . . . . . . . . . . .

b. Reflector dirty . . . . . . . . . . . . . . . . . . . . . . .c. Front window pitted . . . . . . . . . . . . . . . . . .

Searchlight out of vertical ad-justment

Reflector-lamp focal length in-correct.

5-8. Replacement of Fuses(fig. 3-1,3-1.1, and 5-1)

CAUTIONAlways replace a blown fuse with one ofthe same rating and type. If replacement

a. Control Box C-7905A.Rating

Fuse vo/ts Amps

F1 . . . . . . . . . . . . . . . . . . . 250. . . . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . . . . . . . . Search

fuse blows, do not install another fuseuntil the trouble has been remedied.

The following table lists the rating, indication ofblow fuse, and location of fuses within the equip-ment:

Blown fuse indicationbeamwidth will not vary.

modes.

Correction actiona. Replace defective lamp (para 5

13).b. Replace control box (para 5-9).

Refer equipment to direct supportmaintenance.

a. Clean exterior of window (para4-6) and/or interior window(para 5-5).

b. Clean reflector (para 5-5c).c. Replace front windows (para 5-

11).Refer equipment to direct support

maintenance.Refer searchlight to direct support

maintenance.

F2 . .. . . . . . . . . . .250 . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . Searchlight will not switch i l luminationmodes.

b. Control Box C-7905B.Rating

Fuse volts Amps Blown fuse indicationF1 . . . . . . . . . . ..250 . . . . . . . . . . . .2 . . . . . . . . . . . . . . . Search beamwidth will not vary.F 2 . . . . . . . . 250 .. . . . . . . ..1/2 slo-blow . . . . . Searchlight will not switch illumination

To remove and replace, proceed as follows:a. Unscrew the fuse cap counterclockwise and

pull the cap and fuse out of the fuse holder.b. Replace the fuse (2) or (3) in the cap.c. Insert fuse and cap into the fuse holder.d. Turn the cap clockwise until tight.

5-9. Replacement of Indicator Lamps(fig. 5-1)

The procedure for replacement of defective indi-cator lamps in the control box and remote controlbox is as follows.

a. Locate defective indicator and remove byturning indicator lens assembly counterclockwise.

b. Remove defective indicator lamp from indi-cator lens assembly.

c. Insert a new indicator lamp into the indicatorlens assembly.

d. Insert lens in control box or remote control boxand tighten in a clockwise direction.

5-10. Replacementbles.

LocationFront of control box.Front of control box.

Location

Front of control box.Front of control box.

of Searchlight Set Ca-

WARNINGDangerous voltages are present aroundthe searchlight set cables. The search-light must be turned off and the inputpower cable at J 1 on the control box dis-connected before replacing any cables.

No specific instructions are required to replace thesearchlight set cables. Make sure that connectorsare properly aligned and tight when installing thenew cable.

5-11. Replacement of Front(fig. 5-2)

CAUTIONWindow assembly must be

Window

carefully re-moved from searchlight to prevent glassbreakage.

5-4 Change 8

Page 32: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

1 28-volt lamp2 Motor fuse3 Auxiliary B+ fuse4 18-volt lamp

Figure 5-1. Replacement of indicator lamps and fuses.

a. To remove window, perform the followingsteps:

(1) Remove safety bale from window clamphandle.

(2) Unlatch window clamp.(3) Loosen window coupling (1) and remove

front window assembly from flange on front ofsearchlight.

(4) Remove window (2) and gasket (3) fromwindow coupling (1).

(5) Remove gasket from around window. Ifwindow is broken, remove all broken pieces fromgasket.

b. To install window, perform the following steps:(1) Attach the gasket (3) around the new win-

dow.(2) Position the window coupling (1) around the

gasket (3).(3) Position the flange on the front of the

searchlight inside the lip of the window coupling asshown in detail on figure 5-2.

(4) Insure that the window gasket is properlyseated around the flange.

(5) Latch the window clamp.(6) Secure clamp handle with safety bale.

5-12. Replacement of Xenon Lamp(fig. 5-2)

WARNING1. The Xenon lamp is under high internal

TM 11-5855-217-12-1pressure and must be handled with care.If dropped or given a sharp blow, it canexplode violently.2. The glass envelope of the lamp mustnever be touched with bare hands, dirtygloves, or rags. Finger acids and dirt cancause spots on the envelope which, inturn, can cause violent failure of the lamp.3. The spare lamp is contained inside alampholder and held in place by tape cov-ering the open end of holder. The holder isalso used as a tool for removing and install-ing the lamp. To insure personal safetyduring lamp replacement, lamp must al-ways remain inside the holder until lampinstallation has been completed.4. Wear a face mask, asbestos gloves, anda protective apron when removing andreplacing the Xenon lamps.5. The window should not be removed orthe Xenon lamp worked on until thesearchlight has been off for at least 15minutes.

To replace the Xenon lamp, perform the followingsteps:

a. Disconnect the power cable at searchlight toprevent accidental shock.

b. Release safety bail on handle of clamp. Loosenwindow coupling (1) and remove front window as-sembly from flange on front of searchlight.

NOTELeave window gasket around perimeterof window.

c. Remove screw (4), lockwasher (5), and flatwasher (6) holding wire terminal to front of lampclip (8) and remove wire terminal and spacer (7).

d. Remove and retain four screws (9),lockwashers (10), and flat washers (11), holdinglamp clip (8) to front of lamp support assembly.

e. Carefully pull lamp clip (8) and gasket (12)away from lamp support assembly.

f. Insert an empty Iampholder (13) through open-ing in lamp support assembly and slide it inwarduntil end of travel is felt.

g. Unscrew Xenon lamp (14) in a coun-terclockwise direction, using lampholder as a tool.

h. Remove lamp and holder assembly (13 and 14)from lamp support assembly. Tape open end oflampholder to prevent lamp from slipping out ofcontainer.

NOTEDo not discard lamp and holder assemblyuntil procedures listed below have beencompleted.

i. Install replacement lamp and holder (13 and14) through opening in lamp support assembly.

Change 8 5-5

Page 33: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

1 Coupling, clamp grooved 5 Lockwasher2 Front window glass 6 Flatwasher3 Gasket 7 Capacitor4 Screw 8 Lamp Clip

9 screw 13 Lampholder10 Lockwasher 14 Xenon lamp11 Flatwasher 15 Lampholder assembly12 Gasket

Figure 5-2. Replacement of front window and Xenon lamp.

clockwise until Xenoninto place.lamp support assembly.

j. Carefully turn lampholderlamp has been securely fastened

k. Remove lampholder fromSave lampholder for use as a tool for future lamp replace-ment. Insert lamp clip (8) into place by aligning the fourclip mounting holes with the four threaded holes locatedon the face of the lamp support assembly.

1. Install the four screws (9) and washers (10 and 11)to secure lamp clip (8) and gasket (12) to lamp support as-sembly. Make certain that all four screws are tight.

m. Insert spacer (7) into lamp clip (8) and secure wireterminal to lamp clip with a screw (4), lockwasher (5),and flat washer (6).

n. Carefully install window clamp and safety bail.o. Connect power cable to searchlight receptacle.p. Turn searchlight on and check for lamp ignition.

(1) Lamp ignites, see note below.

(2) Lamp does not ignite, see OrganizationalTroubleshooting Chart (para 5-7 item 6).

NOTEBury or discard lamp in such a manner as toavoid personnel coming in contact with Xenonlamp inside lampholder.

5-13. Replacement of SearchlightWARNING

Dangerous voltages are present around thesearchlight assembly. Turn the searchlight set offand disconnect the input power cable from thecontrol box before replacement procedure isstarted.

a. To remove searchlight from the vehicle, peformthe following steps.

(1) Disconnect power cable from receptacle onsearchlight.

5-6 Change 9

Page 34: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

(2) Disconnected and remove the three mounting from vehicle.pins holding the searchlight support to vehicle support b. To replace searchlight on vehicle, perform thewhile searchlight is held by carrying handles by two men. following steps:

(3) Lift searchlight off vehicle support and remove-

Change 9 5-7

Page 35: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

(1) Lift searchlight onto vehicle support andalign support with searchlight mount.

(2) Install the three quick-release pins to con-nect searchlight support to vehicle support.

(3) Connect power cable to receptacle onsearchlight.

5-14. Replacement of Support

a. To remove the searchlight support fromsearchlight, perform the following steps:

(1) Remove searchlight from vehicle (para5- 13).

(2) Set searchlight on left side.(3) Using a suitable wrench, remove the four

bolts and washers attaching the support to thesearchlight.

b. To replace the searchlight support on thesearchlight, perform the following steps:

(1) Position searchlight support on thesearchlight.

(2) Install mounting bolts and washers ontosearchlight support and tighten with a wrench.

5-15. Replacement of Control Box

a. To remove the control box from the vehicleperform the following steps:

(1) Disconnect all cables attached to the con-trol box.

(2) Remove the four screws securing the con-trol box mounting plate to the vehicle.

(3) Remove the control box from the vehicle.b. To replace the control box in the vehicle, per-

form the following steps:(1) Position control box so that the four holes in

the mounting plate are aligned with the fourmounting holes in the vehicle.

(2) Install and tighten four mounting screwssecuring control box to the vehicle.

(3) Attach connecting cables totive receptacles on the control box.

their respec-

TM 11-5855-217-12-15-16. Replacement of Remote Control Box

a. To remove the remote control box from thetank, perform the following steps:

(1) Disconnect cable to remote control box.(2) Remove the four mounting screws and

washers holding the remote control box to the ve-hicle.

(3) Remove the remote control box from thevehicle.

b. To replace remote control box in vehicle, per-form the following steps:

( l) Position remote control box to align the fourmounting holes in the mounting plate with thefour mounting holes in the vehicle.

(2) Install and tighten four mounting screwsthrough mounting plate into vehicle.

(3) Attach remote control box interconnectingcable to receptacle on remote control box.5-17. Reading ELAPSED TIME Meter

a. On some models, the ELAPSED TIME meteris visible from the front of the searchlight.

(1) The ELAPSED TIME meter is mounted onthe upper left of the main support assembly.

(2) Using a flashlight, look into the front of thesearchlight lens to your left above and behind thereflector.

(3) Read and record the elapsed time.b. If the ELAPSED TIME meter is located in the

rear, remove the rear cover to read the time (fig.5-2).

(1) Release the four latches that hold the rearcover to the searchlight.

(2) Remove the rear cover. Be careful not todamage the wires from the searchlight to the rearcover.

(3) The ELAPSED TIME meter is mounted onthe main support assembly,

(4) After checking and recording the meterreading, replace and relatch the rear cover of thesearchlight.

NOTEThe elapsed time meter recordsin hours.

Change 9 5-7.1

Page 36: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

CHAPTER 6

SHIPMENT, LIMITED STORAGE, AND DEMOLITION TO PREVENT ENEMY USE

Section I. DISASSEMBLY

6-1. Disassembly of Searchlight Set

a. Remove the searchlight (para 5-13a).

b. Remove the control box (para 5-15a).

AND REPACKAGING OF EQUIPMENT

6-3. Limited Storage

When the searchlight set is stored for a limitedtime, perform the following procedures:

a. Inventory all components to verify that the

c. Remove the remote control box (para 5-16a).searchlight set is complete and serviceable (fig.1-1 ). Unserviceable spare parts or components

d. Remove the power cable (para 5-10). should be repaired or replaced.b. Thoroughly clean the equipment (para 4-6

a n d 6 - 6 ) . -

6-2. Repackaging c. Remove all traces of rust and corrosion andrepaint surfaces that have been damaged (para

Package the searchlight set as shown in figure 5-4).2-1. d. Place the canvas cover on the searchlight.

Section Il. DEMOLITION TO PREVENT ENEMY USE

6-4. Authority of Demolition

The demolition procedures given in paragraph6-6 will be used to prevent the enemy from usingor salvaging this equipment. Demolition of theequipment will be accomplished only upon theorder of the commander,

6-5. Destruction Plan

Field manuals direct that a destruction plan forequipment will be prepared. Personnel should beassigned specific tasks so that minimum time willbe required if destruction is necessary. Personnelshould be familiar with all aspects of the overalldestruction plan, The plan must be complete, ade-quate, capable of being easily carried out in thefield, and provide for destruction as complete asthe available time, equipment, and personnel willpermit. Because of the time required, completedestruction may not always be available. Fieldmanuals also direct that destruction priorities beestablished to insure that essential parts of equip-ments will be destroyed first, Priority in the fol-lowing order is suggested for the searchlight set:

a. The highest priority for destruction shouldbe given to the major components which are most

essential for searchlight operation; the Xenonlamp, reflector, infrared filter assembly, controlbox, and remote control box.

b. Next to be destroyed are the minor compo-nents; the searchlight window, rear cover assem-bly (heat exchanger), searchlight housing, andpower cable.

c. The technical manual is to be destroyed afterthe minor components are destroyed.

d. The spare parts and the searchlight cover arethe last items in the order of destruction.

6-6. Methods of Destruction

Any or all of the methods of destruction givenbelow may be used. In most instances the availa-ble time will be the single determining factor asto the method to be used for destroying equip-ment. The tactical situation will also determinehow the destruction order will be carried out.However, in most cases it is preferable to com-pletely demolish some portions of the equipmentrather than to partially destroy all the equipment.The destruction methods described in a, b, and cbelow are given in order of preference, Burning isthe preferred method.

6-1

Page 37: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

a. Burning. Burn as much of the searchlight setas is flammable by using gasoline, kerosene, flame-throwers, etc. Remove the window and heatexchanger, pour gasoline on all components insidethe searchlight housing and inside the control box,and on the technical manual, remote control boxpower cable, spare parts, and searchlight cover,and ignite,

WARNING

Be extremely careful in the use of explo-sives and small arms fire. These itemsshould not be used unless extreme ur-gency demands their use.

b. Explosives. Powder charges, fragmentationgrenades, or incendiary grenades may be used inany of the applications given below.

(1) Remove the window or heat exchangerand place a charge or grenade inside the search-light housing.

(2) Pile the remote control box, control boxpower cable, technical manual, spare parts, andcanvas cover and attach a charge or grenade inthe middle of the pile.

WARNING

Use caution and clear the surroundingarea when using small arms fire. Glassand metal fragments may spray out inany direction,

c. Small Arms Fire.

(1) From a safe distance, direct the availablefirepower toward the window of the searchlight. Be sure to destroy the Xenon lamp, infrared filterassembly, and reflector.

(2) Direct firepower toward the heat exchan-ger.

(3) Destroy the remote control box, contrdbox, and power cable.

(4) Destroy the technical manual, spareparts, and canvas cover.

6-7. Methods of Disposal

Bury or scatter destroyed parts and miscellaneousparts or throw them into nearby waterways. Thisis particularly important if a number of partshave not been completely destroyed.

6-2

Page 38: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

APPENDIX A

REFERENCES

The following is a list of the applicable references available toorganizational maintenance personnel of Searchlight Set, Infrared

DA Pam 310-4 Index of Technical Manuals. Technical

the operator andAN/VSS-3A.

Bulletins, Supply.Manuals (Types 7, 8, and 9), Supply Bulletins, andLubrication Orders.

DA Pam 310-7 US Army Equipment Index of Modification Work Orders

SB 11-573 Painting and Preservation Supplies Available for Field Usefor Electronic Command Equipment

SB 38-100 Preservation, Packaging, and Packing Materials, Supplies,and Equipment Used by the Army

TB 43-0118 Field Instructions for Painting and Preserving ElectronicsCommand Equipment Including Camouflage Pattern Paintingof Electrical Equipment Shelters.

M 11-5855-217-12-2

TM 38-750

Operator’s and organizational Maintenance ManualSearchlight Set, Infrared AN/VSS-3 (NSN 5855-00-058-1293)and Searchlight Set, Infrared AN/VSS-3A (NSN 5855-00-177-3529; NSN 5855-00-405-0404) .

The Army Maintenance Managenent System (TAMMS).

Change 9 A-1

Page 39: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

APPENDIX B

BASIC ISSUE ITEMS LIST ANDITEMS TROOP INSTALLED OR AUTHORIZED LIST

SECTION I. INTRODUCTION

B–1. Scope

This appendix lists basic issue items, itemstroop installed or authorized and required bythe crew/operator for operation of theAN/VSS-3A, Federal Stock Numbers5855-177-3529 and 5855-405-0404.

B–2. General

This Basic Issue Items, Items Troop Installedor Authorized is divided into the followingsections:

a. Basic Issue Items List – Section II.A list, in alphabetical sequence, of itemswhich are furnished with, and which must beturned in with, the end item.

b. Items Troop Installed or AuthorizedList – Section III. A list, in alphabeticalsequence, of items which, at the discretion ofthe unit commander, may accompany theend item, but are not subject to be turned inwith the end item.

B–3. Explanation of Columns in the BasicIssue Items List – Section II

a. Illustration, Column 1. This column isdivided as follows:

(1) Figure Number, Column la.This column indicates the figure number ofthe illustration in which the item is shown.

(2) Item Number, Column 1 b.This column indicates the callout number usedto reference the item in the illustration.

b. Federal Stock Number, Column 2.This column indicates the Federal stocknumber assigned to the item and will beused for requisitioning purposes.

c. Description, Column 3. This columnindicates the Federal item name and anyadditional description of the item required. Apart number or other reference number isfollowed by the applicable five-digit FederalSupply Code for Manufacturer (FSCM) inparentheses. The FSCM is used as an elementin item identification to designate manufacturer,distributor, or Government Agency, etc., andis identified in SB 708-42. Identifications ofthe usable on codes used are:

Code Used On

A FSN 5855-177-3529

B FSN 5855-405-0404

d. Quantity Furnished With Equipment,Column 4. This column indicates the quantityof an item furnished with the equipment.

B–4. Explanation of Columns in the ItemsTroop Installed or Authorized List –Section III.

a. Federal Stock Number, Column 1.Indicates the Federal stock number assignedto the item and will be used for requisitioningpurposes.

b. Description, Column 2. Indicatesthe Federal item name and a minimum de-scription required to identify the item. Thelast line indicates the reference numberfollowed by the applicable Federal SupplyCode for Manufacturer (FSCM) in parentheses.The FSCM is used as an element in itemidentification to designate manufacturer,distributor, or Government Agency, etc.,and is identified in SB 708-42. Identificationsof the useable on codes used are:

Change 5

B-1

Page 40: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Code Used On

A FSN 5855-177-3529

B FSN 5855-405-0404

c. Unit of Measure (U/M(, Column 3.Indicates the standard or basic quantity bywhich the listed item is used in performingthe actual maintenance function. Thismeasure is expressed by a two-characteralphabetical abbreviation, e.g., ea, in, pr,etc.

d. Quantity Authorized, Column 4.Indicates the quantity of the item authorizedto be used with the equipment.

Change 5

B-2

Page 41: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM II-SSSS-217-12-1cs

SEcIloW I1 BASIC ISSUE ITEMS(11 rn (31 (4AJSTRATION DESCRIPTION

01

#iII#

F!x%L%!NUMBER

PART NUMBER & FSCM USA&&ON =

A. 8 1l-1 1 5975-123-1527 COVER ASSEMBLY. SEARCHLIGHTSCGS472G2 l(800831

Page 42: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

“Kii?’NUMBER

62501341757

SECTION Ix* ITEMS TROOP INSTALLED OR AUTHDRIZED LIST0E&T,0N

ART NUMBER & FSCMUsA&#OI

EXTRAClOR ASSEMBLY RSISCD646813 WOS3)

A. 8

Page 43: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

A P P E N D I X CM A I N T E N A N C E A L L O C A T I O N

Section 1. INTRODUCTION

C-1. General

This appendix provides a summary of the mainte-nance operations for AN/VSS-3A. It authorizescategories of maintenance for specific mainte-nance functions on repairable items and compo-nents and the tools and equipment required toperform each function. This appendix may be usedas an aid in planning maintenance operations.

C-2. Maintenance FunctionMaintenance functions will be limited to and de-fined as follows:

a. Inspect. To determine the serviceability of anitem by comparing its physical, mechanical, and/orelectrical characteristics with established stand-ards through examination.

b. Test. To verify serviceability and to detect in-cipient failure by measuring the mechanical orelectrical characteristics of an item and comparingthose characteristics with prescribed standards.

c. Service. Operations required periodically tokeep an item in proper operating condition, i.e., toclean (decontaminate), to preserve, to drain, topaint, or to replenish fuel, lubricants, hydraulicfluids, or compressed air supplies.

d. Adjust. To maintain, within prescribed limits,by bringing into proper or exact position, or bysetting the operating characteristics to thespecified parameters,

e. Align. To adjust specified variable elements ofan item to bring about optimum or desired perfor-mance.

f. Calibrate. To determine and cause correctionsto be made or to be adjusted on instruments or testmeasuring and diagnostic equipments used in pre-cision measurement. Consists of comparisons oftwo instruments, one of which is a certified stand-ard of known accuracy, to detect and adjust anydiscrepancy in the accuracy of the instrumentbeing compared.

g. Install. The act of emplacing, seating, or fixinginto position an item, part, module (component orassembly) in a manner to allow the proper func-tioning of the equipment or system.

h. Replace. The act of substituting a serviceablelike type part, subassembly, or module (componentor assembly) for an unserviceable counterpart.

e. Repair. The application of maintenance serv-ices (inspect, test, service, adjust, align, calibrate,replace) or other maintenance actions (welding,

grinding, riveting, straightening, facing, re-machining, or resurfacing) to restore serv-iceability to an item by correcting specific damage,fault, malfunction, or failure in a part, subassem-bly, module (component or assembly), end item, orsystem. This function does not include the trial anderror replacement of running spare type itemssuch as fuses, lamps, or electron tubes.

j. Overhaul. That maintenance effort (service/action) necessary to restore an item to a completelyserviceable/operational condition as prescribed bymaintenance standards (i.e., DMWR) in appropri-ate technical publications. Overhaul is normallythe highest degree of maintenance performed bythe Army, Overhaul does not normally return anitem to like new condition.

k. Rebuild. Consists of those services/actionsnecessary for the restoration of unserviceableequipment to a like new condition in accordancewith original manufacturing standards. Rebuild isthe highest degree of materiel maintenanceapplied to Army equipment. The rebuild operationincludes the act of returning to zero those agemeasurements (hours, miles, etc.) considered inclassifying Army equipments/components.

C-3. Column Entries

a. Column 1, Group Number. Column 1 listsgroup numbers, the purpose of which is to identifycomponents, assemblies, subassemblies, and mod-ules with the next higher assembly.

b. Column 2, Component/Assembly. Column 2contains the noun names of components, as-semblies, subassemblies, and modules for whichmaintenance is authorized.

c. Column 3, Maintenance Functions. Column 3lists the functions to be performed on the itemlisted in column 2. When items are listed withoutmaintenance functions, it is solely for purpose ofhaving the group numbers in the MAC and RPSTLcoincide.

d. Column 4, Maintenance Category. Column 4specifies, by the listing of a “work time” figure inthe appropriate subcolumn(s), the lowest level ofmaintenance authorized to perform the functionlisted in column 3. This figure represents the activetime required to perform that maintenance func-tion at the indicated category of maintenance. Ifthe number or complexity of the tasks within thelisted maintenance function vary at different

Change 8 C-l

Page 44: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

maintenance categories, appropriate “work time”figures will be shown for each category. Thenumber of task-hours specified by the “work time”figure represents the average time required to re-store an item (assembly, subassembly, component,module, end item or system) to a serviceable condi-tion under typical field operating conditions. Thistime includes preparation time, troubleshootingtime, and quality assurance/quality control time inaddition to the time required to perform the spe-cific tasks identified for the maintenance functionsauthorized in the maintenance allocation chart.Subcolumns of column 4 are as follows:

C — Operator/CrewO — OrganizationalF — Direct SupportH — General SupportD — Depot

e. Column 5, Tools and Equipment. Column 5specifies by code, those common tool sets (not indi-vidual tools) and special tools, test, and supportequipment required to perform the designatedfunction.

f. Column 6, Remarks. Column 6 contains an al-phabetic code which leads to the remark in sectionIV, Remarks, which is pertinent to the item oppo-site the particular code.

C-4. Tool and Test Equipment Require-ments (Sect. III)

a. Tool or Test Equipment Reference Code. Thenumbers in this column coincide with the numbersused in the tools and equipment column of theMAC. The numbers indicate the applicable tool ortest equipment for the maintenance functions.

b. Maintenance Category. The codes in this col-umn indicate the maintenance category allocated the tool or test equipment.

c. Nomenclature. This column lists the nounname and nomenclature of the tools and testequipment required to perform the maintenancefunctions.

d. National/NATO Stock Number. This columnlists the National/NATO stock number of the spe-cific tool or test equipment.

e. Tool Number. This column lists the manufac-turer’s part number of the tool followed by theFederal Supply Code for manufacturers (5-digit) inparentheses.

C-5. Remarks (Sect. IV)

a. Reference Code. This code refers to the appro-priate item in section II, column 6.

b. Remarks. This column provides the requiredexplanatory information necessary to clarify itemsappearing in section II.

(Next printed page is C-3)

Page 45: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1SECTION II MAINTENANCE ALLOCATION CHART

FORSEARCHLIGHT SET, INFRARED AN/VSS-3A

Change 9 C-3

Page 46: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

T M ll-5855-217-12-l

SECTION III. TOOL AND TEST EQUIPMENT REQUIREMENTSF O R

SEARCHLIGHT SET, INFRARED AN/VSS-3A

OOLOR TEST M A I N T E N A N C EE Q U I P M E N T C A T E G O R Y

N O M E N C L A T U R E NATIONAL/NATOS T O C K N U M B E R T O O L N U M B E R

REF CODE

1 0 TOOL KIT, ELECTRONIC EQUIPMENT TK-101/G 5180-00-064-5176

2 F.&D MULTIMETER AN/USM-223 6625-00-999-7465(IF hX)T AVAILABLE, USE MULTIMETER TS-352B/U)

3 F.H.D OSCILLOSCOPE AN/USM-2SlA 6625-00-228-2201

4 F.H,D TOOL KIT, ELECTRONIC EQUIPMENT TK-100/G 51SO-00-605-0079

5 F.&D TOOL KIT, ELECTRONIC EQUIPMENT TK-105/G 5180-00-610-8177

6 F,H,D POWER SUPPLY PP-1656/G 6130-00-985-8130

7 D POWER SUPPLY W-4606/G 6130-00-504-0327

8 F.H.D ADAPTER, CONNECTOR 5935-00-004-8840

Page 47: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

SECTION IV. REMARKS

REFERENCECODE

REMARKS

A Items which are not repaired but are listed for information only.

Change 8 C-5

Page 48: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

APPENDIX D

ORGANIZATIONAL MAINTENANCE REPAIR PARTS AND

SPECIAL TOOLS LIST

Section I. INTRODUCTION

D-1. Scope

This appendix lists repair parts, special tools,and test equipment required for the performanceof organizational maintenance of theAN/VSS-3A. Federal Stock Number 5855-177-3529

D-2. General

This repair parts and special tools list is dividedinto the following sections:

a. Repair Parts List—Section II. A list of re-pair parts authorized at the organizational levelfor the performance of maintenance. The list alsoincludes parts which must be removed for re-placement of the authorized parts. Parts listsare composed of functional groups in ascendingnumerical sequence.

b. Special Tools List—Section III. Not Appli-cable.

c. Federal Stock Number and Reference Num-ber Index-Section IV. A list, in ascending nu-merical sequence, of all Federal stock numbersappearing in the listings, followed by a list, inalphanumeric sequence, of all reference numbersappearing in the listings. Federal stock numbersand reference numbers are cross referenced toeach illustration figure number and item numberappearance.

D-3. Explanation of Columns

The following provides anumns in the tabular lists ofIV.

a. Source, Maintenance,Codes (SMR), Column 1.

explanation of col-sections II, III and

and Recoverability

(1) Source Code. Indicates the manner of ac-quiring support items for maintenance, repair oroverhaul of end items. Source Codes are:

Code ExplanationPA . . . . Item procured and stocked for an anticipated

or known usage.PD . . . . . Support item, excluding support equipment,

procured for initial issue or outfitting andstocked only for subsequent or additionalinitial issues or outfittings. Not subject toautomatic replenishment.

Note 1. Cannibalization or salvage may be used as asource of supply for any items source codedabove except, those coded XA and aircraft sup-port items as restricted by AR 700-42.

(2) Maintenance Code. Maintenance codesare assigned to indicate the levels of maintenanceauthorized to USE and REPAIR support items.The maintenance codes are entered in the thirdand fourth positions of the Uniform SMR CodeFormat as follows:USE (THIRD POSITION): The maintenancecode entered in the third position will indicatethe lowest maintenance level authorized to re-move, replace, and use the support item forremoval and replacement at the indicated main-tenance level will require that all the capabilitiesnecessary to install and insure proper operationafter installation of a replacement item (i.e.,preinstallation inspection, testing and post-installation checkout ) are provided. The main-tenance code entered in the third position willindicate one of the following levels of mainten-ance.Code Explanation0. . . . . . Support item is removed, replaced, used at the

organizational level of maintenance.Note 2. A code “C” may be used in this position to denote

crew or operator maintenance performed with-in organizational maintenance.

D...... Support items that are removed, replaced, usedat depot only.

REPAIR (Fourth Position): The maintenancecode entered in the fourth position indicateswhether the item is to be repaired and identifiesthe lowest maintenance level will the capabilityto perform complete repair (i.e., all authorized

Change 5 D-1

Page 49: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

maintenance functions). The decision to code thesupport item for repair at the indicated main-tenance levels requires that all maintenance cap-ability (remove, replace, repair, assemble, andtest) for the support items be provided to thatlevel. This does not preclude some repair whichmay be accomplished at a lower level of main-tenance. However, because of service differencesin communicating maintenance repair level in-formation a maintenance code entry in this po-sition is not required by all services. When amaintenance code is not used a dash (-) signwill be entered. For multi-service equipment/sys-tems or when a code is entered, this position willcontain one of the following maintenance codesas assigned by the service(s) that require thecode.Code Applcation/ExplanationF. . . . The lowest maintenance level capable of com-

plete repair of the support item is DirectSupport.

Z.... Nonreparable. No repair is authorized.

(3) Recoverability Code. RecoverabilityCodes are assigned to support items to indicatethe disposition action on unserviceable items. Therecoverability code is entered in the fifth positionof the uniform SMR Code Format as follows:Code Application/ExplanationZ. . Noreparable item. When unserviceable, con-

demn and dispose at the level indicated in thefirst digit of the maintenance code.

D.... . . Reparable item. When beyond lower level repaircapability, return to depot. Condemnation anddisposal not authorized below depot level.

b. Federal Stock Number. Indicates the Fed-eral stock number assigned to the item and willbe used for requisitioning purposes.

c. Description. Indicates the Federal itemname and a minimum description required toidentify the item. The last line indicates the ref-erence number followed by the applicable FederalSupply Code for Manufacturer (FSCM) in pa-rentheses. The FSCM is used as an element initem identification to designate manufacturer ordistributor or Government agency, etc, and isidentified in SB 708-42.

d. Unit of Measure (U/M). Indicates thestandard or basic quantity by which the listeditem is used in performing the actual mainte-nance function. This measure is expressed by atwo-character alphabetical abbreviation, e.g., ea,in, pr, etc, and is the basis used to indicatequantities and allowances in subsequent columns.When the unit of measure differs from the unit

of issue, the lowest unit of issue that will satisfythe required units of measure will be requi-sitioned.

e. Quantity Incorporated in Unit. Indicatesthe quantity of the item used in the breakoutshown on the illustration figure, which is pre-pared for a functional group. Subfunctionalgroup, or an assembly. A “V” appearing in thiscolumn in lieu of a quantity indicates that nospecific quantity is applicable, e.g., shims, spa-cers, etc.

f. 15-Day Organizational Maintenance Allow-ances.

(1) The repair parts indicated by an aster-ick in the allowance columns represent thoseauthorized for use at the organizational categoryand will be requisitioned on an “as required”basis until stockage is based on demand in ac-cordance with AR 710-2.

(2) Major Army commanders are author-ized to approve reduction in range of supportitems authorized for use in units within theircommands. Recommendation for increase inrange of items authorized for use will be for-warded to the Commander, USA ElectronicsCommand, Maintenance Directorate, AMSEL-MA-S, Fort Monmouth, N.J. 07703. Any changesapproved will be reflected in a revision to the RPSTL.

(3) Allowance quantities are indicated inthe Special Tools List section for special tools,TMDE, and other support equipment.

g. Illustration. This column is divided as fol-lows:

(1) Figure Number. Indicates the figurenumber of the illustration on which the item isshown.

(2) Item Number. Indicates the item num-ber used to reference the item on the illustration.

D-4. Special Informationa. Repair parts kits and gasket sets. Not ap-

plicable.

b. Applicable to revision and/or change only.Action change codes indicated in the left-handmargin of the listing page denote the following:N—Indicates an added item.C—Indicates a change in data.R—Indicates a change in FSN only.

c. The following additional publications per-

D-2 Change 5

Page 50: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

tain to Searchlight Set, Infrared AN/VSS-3Aand its components:TM 11-5855-217-35-1 - - - - - - Direct Support,General Support, and Depot Maintenance ManualIncluding Repair Parts and Special Tools List.

D-5. How to Locate Repair Parts

a. When Federal stock number or referencenumber is unknown:

(1) First. Using the table of contents de-termine the functional group or functional sub-group within which the repair part belongs, i.e.,Control Box, Remote Control box. This is neces-sary since illustrations are prepared for func-tional groups or functional subgroups, and list-ings are divided into the same groups.

(2) Second. Find the illustration coveringthe group or functional subgroup to which therepair part belongs.

(3) Third. Identify the repair part on theillustration and note the illustration figure anditem number of the repair part.

(4) Fourth. Using the Repair Parts List-ing, find the functional group or functional sub-group to which the repair part belongs and locatethe illustration figure and item number noted onthe illustration.

b. When Federal stock number or referencenumber is known:

(1) First. Using the Index of Federal StockNumbers and Reference Numbers find the per-tinent Federal stock number or reference num-ber. This index is in ascending FSN sequencefollowed by a list of reference numbers inascending alphameric sequence, cross-referencedto the illustration figure number and item num-ber.

(2) Second. Using the Repair Parts Listing,find the functional group or functional subgroupof the repair part and the illustration figurenumber and item number referenced in the Indexof Federal Stock Numbers and Reference Num-bers.

(Next pr inted page i s D-3 . )

Change 5 D-2.1

Page 51: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TMll-!%S-217-12-l

1

iC

N

C

\

jc

1

C

C

:

-

P

P

P

P.

PI

‘Pd

9,

PI

PI

PI

PI

PI

PI

PI

PI

PI

PI

P,

N

PC

Pi

Pb

PI

P#

PI

PA

PI

PI

P C

P C

FL

11) (2’ (4’ IO’

&IFEDERAL

DESC %rlONk df”l

NWfR$jT I N C

1bDAY ORO SFMAINT ALLOWANCE

ILLU RAnONS

US#,E60NMEAS ,,lSfT ’

REFERENCENUM9PRLMFRCODE

6656.177.36%

A022 5975-123-1527

AOFD 6655-177.3525

AOFD 5655.177.3527

A022 625&134-1757

DOFD 5855-177-3526

4022 6240-156.7636

4022 5920.280-5342

4022 6920793.4592

4022 6246.651-4352

4022 5340430.7049

4ozz 5655-135-0136

4OZZ 5330143-7716

4ozz 5999-134-5691

4ozz 5305064-6655

4OZZ 5310-929-6396

4OZZ 5310-8805976

4ozz 5330.lSm690

4OZZ 6250.134.1757

4ozz 6230.166-0153

)OZZ 5655-l 14.4949

iozz. 5995.13503Sl

iozz 5655.110-3541

ion 5305-716-6168

\OZZ 5310757.9425

LOZZ 5655.135-0162

\OZZ 5306.052-6456

rOZZ 531D.721.7809

rOZZ 53’35-269-2803

rOZZ 5310061-1259

tozz 5665-114-4953

rOFF 5655.1144964

SEARCHLIGHT SET, INFRAREDANNSS-3A WW561(THlS ITEM IS NONEXPENDABLE1

COVER, SEARCHLIGHTSC0 547201 (60063)

CONTROL, SEARCHLIGHT SETc 7906AJvss-3 wooW

CONTROL, SEARCHLIGHT SETC 7WGAIVSS 3 WJOW

EXTRACTOR ASSEMBLY, RSISCD646613 (60083)

SEARCHLIGHT, INFRAREDMX5272AlVSS.3 1600581

LAMP, INCANDESCENTMS25237 327 (969061

FUSE313001 (75916)

FUSE313002 (759151

LAMP, INCANDESCENT330 lo6606’

COUPLING, CLAMP, GROOVEDscDs46909 @0063)

WINDOW501.2439-401 163003)

SEAL, RUBBER CHANNEL501~2479-401 (63003)

CLIP, LAMP SUPPORT501.2412.401 (630031

SCREW, MACHINEMS51957.31 (96906)

WASHER, LOCKMS35336 136 (969061

WASHER, FLATMS15795806 (969%)

GASKETscc646964 wxx31

HOLDER, LAMPscDe46613 I800631

LAMP AND HOLDERSCD646612 (60063)

INSTALLATION KIT, M551SCD647132 16DO63t

CABLE ASSEMBLY, PWRCX-11693/VSS3 @0066t

PIN. OUICK RELEASESCD646817 160083)

SCREW, CAP, HEXAGON HEADMS90726.110 (96906)

WASHER, FLATMS15795816 I968081

SUPPORT, SEARCHLIGHTSCD646811 l60363)

SCREW, CAP, SOCKET HEADMS16996 10 196906)

WASHER, LOCKMS3634G.43 l96906’

SCREW, CAP, HEXAGON HEADt&90726-60 196906

WASHER, LOCKMS45904.76 196906’

INSTALLATION KIT, M60sGo64716a @ax31

bOUNT ASSEMBLY, SEARtHLIGHTSm647169 c3oo631

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA,

6

Change 7 D-3

Page 52: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

?7@11466&217-12-1

k

iN

,N

;r

IN.

I N

0La!-ho22

ho22

mzt

Aowi

&OZZ

Aozz

A022

A022

A022

m.767-9426

xl6.72E.41S3

ow-177.3S62

306-2w-3m

310891.1740

m-w53444

310-045-3296

31o-8w8546

OW&‘TION

EfERENCENUMBERIYCRCOOPUSA&l&Of

YAstlCR.fLATewxti-818 wmw

JCREW. CAP, HEXAGON WEAD4soo7~113m9oSl

:ABLE ASSY, FWREot34738ows3~

MASHER. iOCKm3w3E46(a68w)

EREW. CAP6SJ726-58WWBl

‘JUT. PLAIN, HEXAGON6S35S91.17 m9oS1

ICREW, MACHINEw36206.260 waJ33)

MASHER, LOCKm3w3s43 w6ao6)

HASHER. FLATdS27183-S tW906)

EA

EA

EA

EA

EA

EA

EA

EA

EA

zI?‘ N I T

4

4

1

4

4

4

4

4

4

1 0% ORGMAIN ALLOWANCEsr

jTI.........

iii-2?

.

.

.

.

.

.

.

.

*

EA

.

.

0

.

.

.

.

.

.

fg

.

.

.

.

.

.

0

.

.

TEllAWE Ic~NTINuE~I

i;;ia

E-4

E.4

E.4

E-4

E-4

E4

E4

E4

2

3

4

6

6

7

8

0

1 0

04 Chanp 7

Page 53: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM11-5855-217-12-1

FEDERALSTOCK

NUMBER

SECTION IV INDEX-FEDERAL STOCK NUMBER CROSS REFERENCE

TO FIGURE AND ITEM NUMBER OR REFERENCE DESIGNATION

FIGURENUMBER

ITEM NUMBER ORREF DESIGNATION

C CODE No. No.

-

C

N

80058

80058

N

N

N

N

C

C

N

80058

08806

96906

96906

N

N

N

96906

96906

96906

96906

96906

96906

1 96906

96906

- 96906

N

N

- 90906

1 90906

90906

90906

90906

C

C

5305-052-6456

5305-054-6655

5305-269-2803

5305-269-3209

5305-716-8186

5305-725-4183

5303-995-3444

5310-004-5033

5310-045-3296

5310-061-1258

5310-721-7809

5310-809-8546

5310-880-5976

5310-767-9425

5310-767-9425

5310-809-8546

5310-891-1749

5310-929-6395

5330-143-7718

5330-180-9890

5340-030-7049

5865-110-3541

5855-114-494

5855-114-49

5855-114-4954

5855-135-0138

5855-135-0162

5855-177-3525

5855-177-3527

5855-177-3528

5855-177-3529

5920-280-8342

5920-793-4592

5975-123-1527

5995-135-0081

5995-177-3562

5999-134-5891

6230-168-0153

6240-155-7836

6240-851-4352

6250-134-1757

6250-134-1757

E-3

5-2

E-3

E-4

E.-3

E-4

E-4

E-4

E-4

E-3

E-3

E-4

5-2

E-3

E-4

E -4

E-4

5-2

5-2

5-2

5-2

E-3

E-3

E-4

E-4

5-2

E-3

1-1

1-1

1-1

1-1

5-1

5-1

1-1

E-3

E-4

5-2

5-2

5-1

5-1

1-1

5-2

6

9

8

6

3

3

8

5

9

9

7

10

11

4

2

10

7

10

3

12

2

2

5

2

3

5 90906

- 80083

2

3

1

1

4

8

15

1

4

4

13

F E D E R A LSTOCK

NUMBER

C

C

N

C

N

N

N

N

C

N

C

N

N

C

N

N

N

N

N

REFERENCENO.

AN/VSS-3A

MX-8272A/VSS-3

C-7S05A/VSS-3

C-7906A/VSS-3

CX-11893/VSS-3

313001

313002

330

501-2412-401

501-2439-401

501-2479-401

MS15795-806

MS15795-818

MS15795-818

MS16996-10

MS25237-327

MS27183-8

MS35206-266

MS35338-136

MS35338-43

MS35338-46

MS35340-43

MS35691-17

MS45904-76

MS51957-31

MS907265-58

MS90726-110

MS90728-113

MS90728-60

SC-C-64964

SC-D-648811

SC-D-6468l2

SC-D-646813

SC-D-646813

SC-D-646817

SC-D-646909

SC-D-647132

SC-D-647168

SC-D-647180

SC-D-647202

SC-D-647380

FIGURE I T E M N U M B E RN U M B E R REF. DESIGNATION

MFG.

80058

80058

75915

75915

83003

83003

83003

90906

80083

80063

80063

80063

80063

80063

80063

80063

80063

80063

80063

FIG.

1-1

1-1

1-1

1-1

E-3

5-1

5-.1

5-1

5-2

5-2

5-2

5-2

E-3

E-4

E-3

5-1

E-4

E-4

5-2

E-4

E-4

E-3

E-4

E-3

5-2

E-4

E-3

E-4

E- 3

5-2

E-3

5-2

1-1

5-2

E-3

5-2

E-3

E-4

E-4

1-1

E-4

ITEM

5

2

3

1

2

3

4

8

2

3

11

4

2

6

1

10

8

10

9

5

7

7

9

9

6

3

3

8

12

5

15

4

13

2

1

1

1

4

N

-

-

N

Change 7 D-5

Page 54: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

E-1. SCOPE

APPENDIX E

AN/VSS-3A FSN 5855-405-0404ORGANIZATIONAL MAINTENANCE REPAIR PARTS AND

SPECIAL TOOLS LIST

SECTION I. INTRODUCTION

This appendix lists repair parts and special toolsrequired for the performance of organizationalmaintenance of the AN/VSS-3A, Federal StockNumber 5855-405-0404.

E–2. General

This repair parts and special tools list is dividedinto the following sections:

a. Repair Parts – Section II. A list ofrepair parts authorized for the performance ofmaintenance at the organizational level. Thelist also includes parts which must be removedfor the replacement of the authorized parts.

b. Special Tools, Test and SupportEquipment – Section III. Not applicable.

c. Federal Stock Number and ReferenceNumber Index – Section IV. A list, in

ascending numerical sequence, of all Federalstock numbers appearing in the listings,followed by a list, in alpha-numeric sequence,of all referenced numbers appearing in thelistings. Federal stock numbers and referencenumbers are cross-referenced to each illus-tration figure number and item numberappearance.

E–3. Explanation of Columns

The following provides an explanation ofcolumns found in the tabular listings:

a. Source, Maintenance, and RecoverabilityCodes(SMR).

(1) Source code. Indicates themanner of acquiring support items formaintenance, repair, or overhaul of enditems. Source codes are:

Code ExplanationPA ---- Item procured and stocked for an-

ticipated or known usage.

P C - - - - - Item procured and stocked and whichotherwise would be coded PA ex-cept that it is deteriorative in na-ture.

PD ----- Support item, excluding supportequipment, procured for initial issue or outfitting and stocked onlyfor subsequent or additionalinitial issues or outfittings. Notsubject to automatic replenishment.

Change -5

E-1

Page 55: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

USE (THIRD POSITION): The maintenancecode entered in the third position will indicatethe lowest maintenance level authorized to re-move, replace, and use the support item. The de-cision to code the item for removal and replace-ment at the indicated maintenance level wiIl re-quire that all the capabilities necessary to installand insure proper operation after installation ofa replacement item (i.e., preinstallation inspec-tion, testing and post-installation checkout) areprovided. The maintenance code entered in thethird position will indicate one of the followinglevels of maintenance.

Code Application/ExplanationO - - - - - Support item is removed, replaced,

used at the organizational level ofmaintenance.Note 2. A code “C” may be usedin this position to denote crew oroperator maintenance performedwithin organizational maintenance,

XA ----- Item is not procured or stocked be-cause the requirements for theitem will result in the replace-ment of the next higher assembly.

NOTE 1. Cannibalization or salvage maybe usedas a source of supply for any itemssource coded above except thosecoded XA and aircraft supportitems as restricted by AR 700-42.

(2) Maintenance Code. Maintenancecodes are assigned to indicate the levels ofmaintenance authorized to USE and REPAIRsupport items. The maintenance codes areentered in the third and fourth positions ofthe Uniform SMR Code Format as follows:

ChangeE-2

REPAIR (FOURTH POSITION): The main-tenance code entered in the fourth positionindicates whether the item is to be repairedand identifies the lowest maintenance levelwith the capability to perform complete repair(i.e., all authorized maintenance functions).The decision to code the support item forrepair at the indicated maintenance levelsrequires that all maintenance capability(remove, replace, repair, assemble, and test)for the support items be provided to thatlevel. This does not preclude some repairwhich may be accomplished at a lower levelof maintenance. However, because ofservice differences in communicating main-tenance repair level information a main-tenance code entry in this position is notrequired by all services. When a maintenancecode is not used a dash (–) sign will beentered. For multi-service equipment/systems or when a code is entered, this

5

Page 56: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

position will contain one of the followingmaintenance codes as assigned by the service(s)that require the code:

Code Application/Explanation

F ----- The lowest maintenance levelcapable of complete repair of thesupport item is Direct Support.

Z ----- Nonrepairable. No repair is author-ized.

(3) Recoverability Code,Recoverability Codes are assigned to supportitems to indicate the disposition action onunserviceable items. The recoverabilitycode is entered in the fifth position of theuniform SMR Code Format as follows:

Code Application/ExplanationZ - - - - Nonrepairable item. When unservice-

able, condemn and dispose at thelevel indicated in the first digitof the maintenance code.

pot. Condemnation and disposal notauthorized below depot level.

L - - - - - Repairable item. Repair condemnationand disposal not authorized below/Specialized Repair Activity level.

A - - - - - Item requires special handling or con-demnation procedures because ofspecific reasons (i.e., precious metalcontent, high dollar value, criticalmaterial or hazardous material).

b. Federal Stock Number. Indicates theFedral stock number assigned to the item andwill be used for requisitioning purposes.

c. Description. Indicates the Federalitem name and a minimum description requiredto identify the item. The last line indicatesthe reference number followed by the appli-cable Federal Supply Code for Manufacturer(FSCM) in parentheses. The FSCM is usedas an element in item identification to designatemanufacturer, distributor or Government agencyetc., and is identified in SB 708-42.

d. Unit of Measure. Indicates thestandard or basic quantity by which thelisted item is used in performing the actualmaintenance function. This measure isexpressed by a two character alphabeticalabbreviation, eg., ea., in., pr., etc. Whenthe unit of measure differs from the unit ofissue, the lowest unit of issue that will satisfythe required units of measure will berequisitioned.

D - - - - - Repairable item. When beyond lowerlevel repair capability, return to de-

Change 5

E-3

e. Quantity Incorporated in Unit. In-dicates the quantity of the item used in thebreakout shown on the illustration figure,which is prepared for a functional group,subfunctional group, or an assembly. A “V”appearing in this column in lieu of a quantityindicates that no specific quantity isapplicable, e.g., shims, spacers, etc.

Page 57: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

f. l5-Day Organizational Maintenance Allowances.

(1) The repair parts indicated by an asterick in the allowance columns

represent those authorized for use at the organizational category and will be

requisitioned on an “as required” basis until stockage is based on demand

in accordance with AR 710-2.

(2) Major Army commanders are authorized to approve reduction in range of

support items authorized for use in units within their commands. Recommendation

for increase in range of item authorized for use will be forwarded to the

Commander, USA Electronics Command, Maintenance Directorate, AMSEL-MA-S,

Fort Monmouth, N.J. 07703. Any changes approved will be reflected in a

revision to the RPSTL.

(3) Allowance quantities are indicated in the Special Tools List

section for Special tools, TMDE, and other support equipment.

g . Illustration. This column is divided as follows.

(1) Figure Number. Indicates the figure number of the illustration on

which the item is shown.

(2) Item Number. Indicates the item number used to reference the item

on the illustration.

E-4. Special Information.

a. Repair parts and gasket sets. Not Applicable

b. Applicable to revision and/or change only. Action change codes

indicated in the left-hand margin of the listing page denote the following;

N - Indicates an added item.

C - Indicates a change in data.

R - Indicates a change in FSN only.

c. The following additional publications pertain to Searchlight Set,

Change 5

E-4

Page 58: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Infrared AN/VSS-3A and its components:TM 11-5855-217-35-1– Direct Support, GeneralSupport, and Depot Maintenance Manual IncludingRepair Parts and Special Tools List.E-5. How to Locate Repair Parts

a. When Federal stock number or referencenumber is unknown:

(1) First. Using the table of contents determinethe functional group or functional subgroup withinwhich the repair part belongs, i.e., Control Box,Remote Control, Box. This is necessary sinceillustrations are prepared for functional groups orfunctional subgroups, and listings are divided intothe same groups.

(2) Second. Find the illustration covering thegroup or functional subgroup to which the repairpart belongs.

(3) Third. Identify the repair part on theillustration and note the illustration figure and itemnumber of the repair part.

(4) Fourth. Using the Repair Parts Listing,find the functional group or functional subgroup towhich the repair part belongs and locate theillustration figure and item number noted on theillustration.

b. When Federal stock number or referencenumber is known:

(1) First. Using the Index of Federal StockNumbers and Reference Numbers find the pertinentFederal stock number or reference number. Thisindex is in ascending FSN sequence followed by a listof reference numbers in ascending alphamericsequence, cross-referenced to the illustration figurenumber and item number.

(2) Second. Using the Repair Parts Listing,item the functional group or functional subgroup ofthe repair part and the illustration figure numberand item number referenced in the Index of FederalStock Numbers and Reference Numbers.

Change 7 E-5

Page 59: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure E-1. Infrared Searchlight Set AN/VSS-3 (A).

E-6 Change 7

Page 60: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

II)a

CODE

-

‘A022

‘A022

‘A022

‘A022

‘AOZi

‘AOFC

‘A022

‘A022

‘AOZi

‘A022

‘AOF[

‘DOFI

(2)

“FEi?’NUMBER

1975-123-1527

iml-134.1757

i210-022.7981

i240155-7836

i21D.022.7980

$355451.5224

3210.464.0447

1240851 4352

i920.199.B498

5855 16%6D65

%55-169.6086

SECTION II REPAIR PARTS FOR ORGARlZArlORA(3)

DESCRIPTION

EFERENCENUMEER&MFRCODEUSA&L&OI

SEARCHLIGHT SET, INFRARED AN/VSSJ(AI

COVER ASSEMBLY.SEARCHLIGHTSCD647202.1 WCC631

EXTRACTOR ASSEMBLY, RSISCD646B13 @CO631

LENS, INDICATOR LIGHTLC37RD2 181349)

LAMP, INCANDESCENTMS25237-327 lS6BWl

LENS, INDICATOR LIGHTLC37GD2 181349)

CONTROL, SCHLT SET, C7BCWBlNSS3SCD646W2.1 (80083)

LENS, INDICATOR LIGHTLC37CD2 1613491

LAMP, INCANDESCENTMS25237-330 i96BW

FUSE, CARTRIDGEFO2B125Vl 2A (813491

FUSE, CARTRIDGEF02A125VZA (61349)

CONTROL, SCHLT. C76G5(Bl/VSS3SCD647251.1 180063)

SEARCHLIGHT, IR. MX8272lBWSS3SCD647252 1 (800631

i(41

tNl1

1::

E#

E,

E.

E.

E.

E.

E.

E,

E

E

E

E

lM11q5sgt742-t

TERARCEI161

ISDAY ORGMAINT ALLOWANCE E

is!

E.

E

E.

E.

E-

E.

L.

E.

E.

E.

E.

E.

1

2

5

6

7

6

11

12

13

14

15

16

Page 61: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure E-2. Searchlight, Infrared MX8272B/VSS-3.

E-8 Change 7

Page 62: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

r-E

022

022

022

,022

,022

,022

,022

ro22

(022

LO22

&022

ho22

:022

ro22

4022

ro22

to22

-12)--%ELNUMBER

ID-D3@7Q46

i5-0044903

!m544552

10.722.5SBS

10-I ,34B24

lO.Go8.7436

55-2345147

35.15D4764

10.9266%5

70-4BBQSa

55-003.3230

30. i Bo&wo

50-134-1757

55

‘WiSB~O153

140.687 I!48

FERENCE NUMBER & MFR CODE.B#g&OO

__a*= :--

SEARCHLIGHT, INFRARED MX6272lB~N~3

DUCLING. CLAMP, GROOVED:064esDs wo63~

,NDOW A:SEMELY. SEARCHLIGHTZWtBSl4 1 WC83)

,REW. MACHINEIS51857-28 ls6wm

‘ASHER. FLAT1s15795405 ls6sQ51

ERMINAL. LUGD2M59 107 w6sw

.APACITOR ASSEMBLYCC8471?2~1 1SCo631

PACER, RING731 I833301

CREW, PANEL, CAPTIVE13ossm32.7 108540401

IASHER. LOCK1m1m Isz%w

IASHER. CAPTIVE66647101 WD63l

‘ASHER. RETAININGC6647277 1 mo63l

LIP. FRONT LAMP SUPPORTcD646962.1 !S?xS3l

IASKETCc546964 l6a63l

XTRACTOR ASSEMBLY, RSIcoSw13 [email protected]

AMP. XENONCD64S431 i6W631

.AMP AND EXTRACTOR ASSEMBLYCD64S4S12 1S0x.31

:AP. DUSTt62517032

x................

.

.

.

.

.

.

.

.

.

.

MAW ALLOWANCE

6

-2“ 2

-2

-2

-2

- 2

..a

:.2

i-2

I-2

i-2

i.2

i.2

!.2

I-2

i-l

E-2

1

2

3

4

5

6

7

6

6

6A

t0

11

12

13

14

16

16

Page 63: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure E-3. Adapter Kit M-551.

E-10 Change 7

Page 64: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

PECTIIM II REPIIR pI#rs FOR ORGMlZATlONM MAIWTENANCE

N

N

---- .--- . . ____.____ _.._._ - ~-~~ ~~~-~

111 121 (31 (41 15) 16)DESCRIPTION

Ut;T T;;15OAY ORG .d”ILLU RATION5

wl F%cR~LMAlNT ALLOWANCE

ODE NUMBERREFERENCENUMBERLMFRCODE

US$~~EON MEAS UzT pan ,jg 2iyk 5j-y) AldikN%~DESIGNATION

.

ADAPTER KIT. M-551

,022 5995.135.co51 CABLE ASSEMBLY, PWR. CX-11593/VSS-3 EA ( * * f * E-3 1SCD546503-1 ~500631

LOZZ 5555-110-3541 PIN, OUICK RELEASE EA 3 * * * * E-3 2SCD646517 (500631

iozz 5305-716-5156 SCREW, CAP, HEXAGON HEAD EA 4 . * . . E-3 3MS90726-110 1969%)

rOZZ 5310.767-9425 WASHER, FLAT EA 4 l * l * E-3 4MS15795-515 (96906)

rOZZ 5655135.0152 MOUNT ASSEMBLY, SEARCHLIGHT EA 1 . . * . E-3 5SC064661 1.1 wo53~

9zz 5305-0526456 SCREW, CAP, SOCKET HEAD EA 4 * * f E.3 5MSl6996-10 (96906l

rOZZ 5310-721.7608 WASHER, LOCK EA 4 * . . . E-3 7MS35340-43 196905)

rOZZ 5305-259-2603 SCREW, CAP, HEXAGON HEAD EA 4 . . . * E-3 6MS9072660 196906)

razz 5310-061-1256 WASHER, LOCK EA 4 . l . * E-3 9MS45904.76 W59CSl

‘Chanfp 7 E-11

Page 65: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Figure E-4. Adapter Kit M-60.

E-12 Change 7

Page 66: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

I1

\

N

N

N

N

N

N

\

rn”..VR . . --. -._ _ _____ _ ___ ____-.._. -I.-0 rn” . . . . w--.-v-

._.

(11 u)DEsrhr I IVR

YRFEDERAL

DDE NfWRREFERENCENUMBERLMFRCODE

(3) 1 (4’ I_(!!.1 ((II I71I~Il..rI~U ‘SDAY ORG ILLUSTRATIONST ALLOWANCE ’

““~~-o-~E-.DESIGNATION

I I I I IADAPTER KIT, M-60

O F F 5855-114-4954

I,0ZZ 5310-767-9425

I

SCREW, CAP, HEXAGON HEADMS80728-113 96906

CABLE ASSY, PWR, CX11883/VSS-3SCD847380 80063

,0ZZ 5305-725-4183

,0ZZ 5995-177-3562

,0ZZ 5310-004-5033 WASHER, LOCKMS3633B-46 (SBBmll

,022 5306-288-3208

,022 5310-891-1749

LOi%! 6305-986-4444

\OzZ 5310-045-3286 WASHER, LOCKuelc?-an*? ,ollMRI

SCREW, CAPMSBO726.58 PBBW

NUT, PLAIN, HEXAGONMS3SBBl-17 @BmBl

SCREW, MACHINEMS3623BJBB @BBO6l

MOUNT ASSEMBLY, SCHLT, M-60SCD8471BB-1 eooB3~~

IwrY”“- 7” ,““““-,

WASHER, FLATMS271B3.B (88808)

Change 7 E-13

Logsa LOGSA
5310-808-8546
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
1
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
4
Logsa LOGSA
MS15795-818 (96906)
Logsa LOGSA
WASHER, FLAT
Logsa LOGSA
1
Page 67: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM11-5855-217-12-1

SECTION IV INDEX-FEDERAL STOCK NUMBER CROSS REFERENCE

TO FIGURE AND ITEM NUMBER OR REFERENCE DESIGNATION

FEDERALSTOCKNUMBER

FEDERALSTOCK FIGURE ITE!M NUMER OR

NUMBER NUMBER REF. DESIGNATIONFIGURENUMBER

ITEM NUMBER ORREF. DESIGNATION

6250-134-1757 E-2 13E-3

E-2

E-2

E-3

C 5305-062-6456

5305-054-8852

5305-150-4794

5305-269-2803

5305-269-3209

5305-716-8186

5305-725-4183

5305-995-3444

5310-

5310-004-5033

5310-045-3296

5310-061-1258

5310-721-7809

5310-722-5998

5310-787-9425

5310-767-9425

5310-809-8546

5310-891-1749

5310-929-6395

5310-180-9890

5330-030-7049

5340.687-1148

5385-234-5147

5855-

5855-003-3230

5855-004-0903

5855-110-3541

5855-114-4949

5855-114-4953

5855-114-4954

5855-135-0162

5855-189-6065

5855-l89-6066

5855-451-5224

5910-008-7436

5920-199-9498

5920-

5940-113-9824

5970-486-0564

5975-123-1527

5905-136-0081

5995-177-3562

6210-022-7980

6210-022-7981

6210-464-0447

6230-168-0153

6240-155-7836

6240-851-4362

6250-134-1757

6

3

8

8

6

3

3

8

9A

5

9

9

7

4

4

2

10

7

9

12

1

16

7

14

11

2

2

FIGURENUMBER

REFERENCENUMBER

MFG.CODE NUMBER

14

13

C

N F02A125V2A 81349 E–.1E-4

E-3

E-4

E-4

F02B125V1-2A 81349 E–.1

LC37CD2

LC37GD2

81349

81349

81349

E–.1

E–.1

E-l

11

7

5

N

LC37RD2E-2

E-4

E-4

E-3

N

N

C

C

MS15795-805

MS15795-818

MS15795-818

MS16996.10

96906

96906

96906

E-2

E-3

E-4

E-3

E-2

4

4

96906

2

6

5

CE-3

E-2

E-3

E -4

MS20659-107 96906

MS25178-32

MS25237-327

MS25237-330

96906 E-2

E-l

E-1

E-4

16

96906

96906

96906

6

12

10

8

9

9

N

N

E-4

E- -4

E-2

E-2

N

N

MS27183-8

MS35206-266

MS35338-139

MS35338-43

96906 E-4

96906 E-2

N

NCN

C

96906 E-4E -2

E-2

E-2

E-2

96906

MS36340-43MS35338-46

MS35691-1796906

E-4E-3E-4

57796906

MS45904-76 96906 E-3

96906

9

3

6

MS51957-28 E-2E-2

E-2

E-3

E -3

E -4

96906 E-4N MS90725-58

MS90726-110

MS90726-113

MS90726-60

96906 E-3

– 96906

3

3

8

9A

– 96906

E-4

E.-3

E-2

80063

1

E-1

1

5

15

16

8

6

13

14

5

10

1

1

4

7

5

11

15

6

12

2

C

SC8647181 80063

80063

80063

E-.4

E-3

E--1

E-l

SC8647277-1

SCC640964

SCC647122-1

E -2

E-2

E-2

E-l

E-3

10

12

6

8SCC647122-1 80063

80063

80063

80063

80063

80063

80063

E--1

E-2

E-l

SCD646802-1

SCD646811-1

SCD646812

E-3

E-2

E-l

E-2

5

15

2SCD646813E-2

E-2

E-l

E-3

SCD646813

SCD646817

SCD646909

SCD646914-1

13

80063

E-3

E-2

E.2

E-2

2

1

280063E-4

SCD646931E-l

E-l

E-l

E-2

80063 14

SCD646962-1

SCD647132-1

SCD647168-1

SCD647180-1

80063

80063

80063

8O063

80063

80063

E-2

E-3

E-4

11

-

1

E-1E-4 -

E-l

E-l

SCD647202-1

SCD647251-1

E-l

E-1

1

15

E - 1 4 C h a n g e 7

Page 68: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM11-5855-217-12-1

FEDERALSTOCK

NUMBER

FIGURENUMBER

SCD647252-1

SCD64380

6130SS0632-7

8731

SECTION IV INDEX-FEDERAL STOCK NUMBER CROSS REFERENCE

TO FIGURE AND ITEM NUMBER OR REFERENCE DESIGNATION (c O N T I N U E D )

FIGURE ITEM NUMBER ORNUMBER REF. DESIGNATION

80063 E--1 16

80063 E -4 4

06540 E-2 8

83330 E-2 7

FEDRAL

NUMBER

ITEM NUMBER ORREF. DESIGNATON

Change 7 E-15

Page 69: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

I N D E X

P a g e

Addit ional equipment required- - - - - - - - - - - - - - - - - - - - - - - - - - - - - Adjustments, beam width - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Arctic climates, operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Authority, demolition - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - -

Beam width adjustment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Characteristics, technical - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Charts:

O p e r a t o r ’ s w e e k l y p r e v e n t i v e m a i n t e n a n c e c h e c k s a n d s e r v i c e s - - - - - - - -Organizational monthly preventive maintenance checks and services - - - - - - - - - - -

Checking unpacked equipment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Checks and services required- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Cleaning procedures:

Operator’s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Organizational - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Components, table - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Control box, replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Control settings, preliminary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Controls, searchlight - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Demolition, authority - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Description:

Equipment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Minor components - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Desert climates, operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Destruction:

Methods - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Plan - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Disassembly - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Disposal, methods - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Equipment:Description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -R e q u i r e d , a d d i t i o n a l - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

E m e r g e n c y s t o p p i n g p r o c e d u r e - - - - - - - - - - - - - - - - - - - - - - - Exchanger, heat - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Fording - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Forms and records - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Functional names - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Fuses, replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

General:Organizat ional troubleshoot ing and repairs - - - - - - - - - - - - - - - - - - - - -

Heat exchanger - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Indeces of publications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Indicator lamps, replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Indicators, searchlight - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Limited storage shipment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Lubrication - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - -

Materials required for operator maintenance - - - - - - - - - - - - - - - - - - - - - - - - -

Methods:Destruction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Disposal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Minor components, description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Paragraph

1-103-73-126 - 4

8-7

1 - 5

4-55 - 32 - 24 - 4

4-65-51-65-153-56-3

6-3

1-81-93-14

6 - 66-56-16-7

1-81-103-103 - 4

3-111-31-75-10

5-6

8-4

1-25-93 - 2

6 - 34 - 7

4 - 2

6 - 66 - 71-9

1 - 33 - 33 - 46 - 1

3 - 3

1 - 1

4 - 15 - 12 - 14 - 1

4-35-21-25 - 83 - 26 - 1

6 - 1

1 - 21 - 33 - 4

6-16-16-16-2

1-31-33-43-2

3-41-11-25-5

5-3

3 - 2

1-15 - 53 - 2

6 - 14-3

4-1

6-16-21-3

I - 1

Page 70: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Paragraph Page

Modes, operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Monthly maintenance, organizational - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3 - 85 - 3

Names, functional- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Normal stopping procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1 - 73 - 9

3 - 35 - 1

1 - 23 - 4

3 - 43 - 43 - 33 - 43 - 5

O p e r a t i o n :Artic climates - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Desert climates - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Modes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Tropical climates - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Under saltwater spray environment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Operator maintenance:Cleaning procedures - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Materials required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Preventive maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Scope - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Troubleshooting chart - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Troubleshooting procedures - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Weekly preventive maintenance checks and service chart - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Organizational maintenance:Cleaning procedures - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Monthly preventive maintenance checks and service chart - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Preventive maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Scope - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Tools and materials required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Troubleshooting chart - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -

3-123-143-83-133-15

4 - 64-44-84-14 - 84-84 - 5

4-24 - 14 - 14 - 14-34-34 - 1

5-55-35-35-15 - 25-7

5 - 25 - 15 - 15 - 15 - 15 - 3

5 - 26 - 15 - 53 - 2

4 - 15 - 1

Painting and refinishing procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Plan, destruction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Power cable, replacement - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

5-46-55-103-6Preliminary control settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Preventive maintenance:4-35-3

Operator’s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Organizational - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Procedure:Emergency stopping - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-10

3 - 95-43-61-21-4

3-43 - 45-23-21-11-1

Normal stopping - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Painting and refinishing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Starting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

P u b l i c a t i o n s , i n d e c e s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Purpose and use (fig. 1-1) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1-35-16

R e c o r d s , f o r m s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -R e m o t e c o n t r o l b o x , r e p l a c e m e n t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Replacement:

C o n t r o l b o x - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-155-85 - 95 - l 05-165-135-145-115-124-4

F u s e s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -I n d i c a t o r l a m p s ( f i g . 5 - 3 ) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -P o w e r c a b l e - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -R e m o t e c o n t r o l b o x - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -S e a r c h l i g h t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -S e a r c h l i g h t m o u n t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -W i n d o w - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -X e n o n l a m p - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

R e q u i r e d c h e c k s a n d s e r v i c e s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1 - 15 - 8

5 - 85 - 45 - 55 - 55 - 85 - 65 - 75 - 55 - 64 - 1

3-15 3-5S a l t w a t e r s p r a y e n v i r o n m e n t s , o p e r a t i o n - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Searchlight:

C o n t r o l s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -I n d i c a t o r s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -M o u n t , r e p l a c e m e n t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -R e p l a c e m e n t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

S e r v i c i n g - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -S h i p m e n t , l i m i t e d s t o r a g e - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -S t a r t i n g p r o c e d u r e - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3-13-25-145-132-106-33 - 6

3 - 13 - 25 - 75 - 62 - 56 - 13 - 2

I-2

Page 71: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

Table, components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Technical characteristic . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tools and materials required, organizational maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tropical climate operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Trobleshooting chart

Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Organizational . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Procedures, operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unpacked equipment checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Unpacking . . . . . . . . . . . . .... . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Window. replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Xenon lamp, replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . .. . . . . . . . . . ... ..

Paragraph

1-61-55-2

3-13

4-85-74-82-22-1

5-115-12

Page

1-21-15-13-4

4-35-34-32-12-1

5-65-5

1-3

Page 72: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

TM 11-5855-217-12-1

By Order of the Secretary of the Army

Official:KENNETH G. WICKHAM,Major General, United States ArmyThe Adjutant General

Distribution:

Active Army:USASA (2)CNGB (1)USACDCCEA (1)USACDCCEA

Ft Huachuca (1)USAMB (10)USAARENBD (2)USAMC (1)USCONARC (5)OS Maj comd (5)LOGCOMD (2) except

1st LOGCOMD (10)9th LOGCOMD (l0)

USAECOM (10)Armies (5) except

Eighth (15)USARV (20)USAARMS (30)USAOC&S (5)USAFAS (30)USAIS (30)USAES (5)USATC Armor (5)USACDCEC (10)Sig FLDMS (1)

NG: State AC (3).

USAR: None.

For explanation of abbreviations used, see AR 310-50.

W.C. WESTMORELAND,General, United States ArmyChief of Staff

Army Deps (1) exceptLEAD (3)TOAD (5)SAAD (5)ATAD (5)

Gen Deps (2)Sig Dep (3)Sig Sec Gen Depa (3)MAAG (1)USARMIS (1)Units org under fol TOE:

(2 copies each)11-15611-500 (AA-AC)1717-1517-1617-1717-3717-4217-513737-10037-102

*U.S. GOVERNMENT PRINITING OFFICE : 1992 0 - 311-831 (60853)

Page 73: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The
Page 74: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

THE METRIC SYSTEM AND EQUIVALENTS

Page 75: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

PIN: 018628-010

Page 76: SEARCHLIGHT SET, INFRARED AN/VSS-3A NSN 5855-00-177 … · AN/VSS-3A 5855-00-177-3529 5855-00-405-0404 This copy is a reprint which includes current pages from Changes 1 through 10.The

This fine document...

Was brought to you by me:

Liberated Manuals -- free army and government manuals

Why do I do it? I am tired of sleazy CD-ROM sellers, who take publicly available information, slap “watermarks” and other junk on it, and sell it. Those masters of search engine manipulation make sure that their sites that sell free information, come up first in search engines. They did not create it... They did not even scan it... Why should they get your money? Why are not letting you give those free manuals to your friends?

I am setting this document FREE. This document was made by the US Government and is NOT protected by Copyright. Feel free to share, republish, sell and so on.

I am not asking you for donations, fees or handouts. If you can, please provide a link to liberatedmanuals.com, so that free manuals come up first in search engines:

<A HREF=http://www.liberatedmanuals.com/>Free Military and Government Manuals</A>

– SincerelyIgor Chudovhttp://igor.chudov.com/

– Chicago Machinery Movers