SEADM DMA
SEADM supercritical DMA works at atmospheric pressure so direct API coupling is possible with minor MS interface modifications.
1
Convert an existing mass spectrometer into an hybrid Ion Mobility-Mass Spectrometry instrument
Sociedad Europea de Análisis Diferencial de Movilidad S.L. www.seadm.com
2
Introduction – SEADM’s proposal
Are you involved in structural elucidation of molecules, particle
or nanoparticle analysis, atmospheric research, or polymer
technology?
Do you need an improvement on your MS (mass spectrometer
) selectivity responding much faster than gas or liquid
chromatography?
Are you thinking of adding mobility dimension to your
analysis?
SEADM’s supercritical DMA (Differential mobility analyzer) may
be the upgrade you are looking for.
In our eagerness to be able to analyze both atmospheric and
biological samples at the challenging fentogram level, we have
faced sensitivity and selectivity problems unsolved by
commercial devices. In collaboration with colleagues at Yale
University, we have developed high resolution supercritical
mobility analyzers that allow for unprecedented selectivity and
sensitivity for rapid measurements.
The DMA measures true linear mobility and therefore is a
powerful tool for structural studies of biomolecules.
Adding the mobility dimension enables mass distribution
measurements in industrial polymers where pure mass spectra
are generally unresolvable at moderate and large molecular
weights.
In the field of explosive trace detection in air, an important area
of expertise for SEADM, mobility analysis together with high
sensitivity MS leads to detection limits below 1pg/m3 in some
cases.
3
Comercial options available
Enhanced ionization option: Instead of the basic ionization chamber, for high sensitivity volatile analysis, an improved LFSESI (Low flow secondary electrospray ionization) or a full metal chamber for APCI can be purchased. Both include temperature control and can be used as nano ESI, SESI, or APCI. The ionization efficiency can reach values of 1/700 (in the case of TNT vapors in a LFSESI).
DMA basic system: The basic system consist of a fully operative DMA device ready to be plugged to a MS in the list below with minor modification of MS interface. With a modest level of effort the DMA may be coupled essentially to any MS with an atmospheric pressure interface. The basic system includes all HV supplies, pressure and flow controls, clean recirculation pump and circuit, and a basic ionization chamber for either nano-spray or corona discharge APCI. Only standard power supply and around 1 lpm extra clean gas is required. DMA-MS integration: Choose your MS We have experience coupling DMAs to the following MS: - Shimadzu LCMS 2010 de. -ABSciex TOF Qstar -ABSciex Qtrap 3200, 4500 & 5500 -ABSciex Triple Quad 5000 & 5500 -If your favorite MS is not in this list, we will carry out the integration study for you.
4
High pressure desolvation option: For samples producing substantial solid residues, or when solvent droplets are a problem, there is a version of the basic DMA with an additional mobility stage with the double function of drying and filtering sample droplets. It is only available with LFSESI chamber and requires up to 30 lpm extra clean gas supply.
Standalone devices for developers: If you are a developer and you are interested in a custom or standalone device, there is a range of products we can offer you, including air sampling devices, ionization chambers, volatility analyzers, cylindrical DMAs... please feel free to contact us and we will be happy to study your application and suggest you the best option.
Supercritical Planar Mobility Analyzer - Technology Advanced design The geometry and aerodynamics of the DMA have been carefully optimized to deliver a laminar flow at Reynolds number up to 200,000, achieving resolving powers >50 The potential of DMAs for molecular cross section studies, mass pre-filtering and noise reduction have been traditionally limited by low resolution at nanometric sizes, a difficulty now resolved by use of supercritical DMAs. These devices keep the flow laminar at Reynolds numbers considerably higher than 2,000.
Color scale: Velocity magnitude in m/s
Careful manufacturing All manufacturing improvements discovered over the years are implemented on SEADM’s DMAs. Robust architecture, mirror polishing, micro slots or whole thermal control are only some of the improvements included on SEADM’s DMAs. These refinements are the step forward towards accurate and reliable mobility measurement at atmospheric pressure.
High performance about 50% transmission, 1,000 dynamic range and resolving power up to 100 at 1nm. The standalone DMA is capable of distinguishing quantities of around 1ppb of many molecules such as TNT. Combined with MS the limit of detection of TNT reaches 1ppq. The improved software for post signal processing permits isomeric distinction between ions only separated by 1x10-6m2/V/s (mobility units).
(a) Robust design tested under extreme conditions (bumpy journeys, high temperature…)
(b) Mirror polishing to delay turbulent transition. (c) Micro slots to maximize resolution.
(d)
(e)
(b)
(c)
(a)
(d) Spectra of various tetra-alkyl-ammonium positive ions clearly separated by mobility.
(e) Isomeric species of TNT present at tiny quantities on atmospheric air only distinguished from real TNT trough mobility analysis. 5
Ionization Chamber: SEADM is specialized on nanoESI & LFSESI, but other techniques such as
APCI are also possible
DMA- MS Interface: Easy and fast connection without breaking vacuum. You can return to basic
MS configuration in a few minutes.
Planar DMA: Inlet and outlet slots are accessible allowing high transmission and easy integration with the ionization chamber and the mass spectrometer.
Mass Spectrometer: The coupling with commercial MS lets you take advantage of
state of the art technology changing every day.
Tandem system – 2D analysis Synergy between DMA – MS for breakthrough figures A combined DMA-MS instrument in triple quadrupole mode is capable of reaching unimaginable sensitivity levels on this field until now. It allows molecule, cluster and nanoparticle identification up to several nm diameter with sensitivities below 1pg/m3.
Sample 2D fingerprint A complex sample can be simultaneously mass and mobility analyzed. The DMA enables 2D analysis of any sample with any MS. Furthermore, fast 2D discovery mode is possible with TOF and Trap spectrometers. In this mode 2D plot can be obtained in minutes. Two-dimensional plot of ion
abundance (color scale) as a function of mass/charge (y axis) and DMA voltage (x axis). Each light region corresponds to an ion.
6
Our commitment: Your scientific success
Sociedad Europea de Analisis Diferencial de Movilidad SL
(SEADM) is a Spanish SME founded in 2005 with the aim of
developing a new generation of analytical instruments able to
detect trace ambient vapors at the subfemtogram level, both in the
atmosphere or within the body fluids, based on extensions of prior
developments at Yale University.
We have an eight-year trajectory developing state of the art
mobility analyzers, and ionization chambers. There is also an
important area of expertise in SEADM on explosive trace detection
in ambient air.
For more details on scientific uses of our technologies see
http://www.seadm.com/papers.html
The range of products we offer goes from the basic and affordable
standalone DMA, to the complete ultra-sensitive detection system
with all the modules and the cutting-edge spectrometers, also
including the handy option of the DMA as an add-on to your
current spectrometer.
It is of SEADM highest interest to cooperate with your research
projects, so please feel free to contact us, and we’ll try to offer you
the best option for your required application.
For more information visit: www.seadm.com
For Research Use Only. Must be handled by trained personnel. Contact: Arturo Alvaro Carballido, R&D Manager (SEADM) Phone : +34 983130707 e-mail: [email protected] Sociedad Europea de Analisis Diferencial de Movilidad S.L. | www.SEADM.com Parque Tecnologico de Boecillo. Parcela 205. 47151 Valladolid, Spain.
7
8 Sociedad Europea de Analisis Diferencial de Movilidad S.L. | www.SEADM.com Parque Tecnologico de Boecillo. Parcela 205. 47151 Valladolid, Spain. Phone : +34 983130707 e-mail: [email protected]