schematics electric & gas...sp8024-1402 schematics electric & gas 8415 north clinton park dr...
TRANSCRIPT
SP8024-1402
SCHEMATICS ELECTRIC & GAS
8415 North Clinton Park Dr · Fort Wayne, IN 46808 · 800.480.0415 · Fax 260 469-3045 · email:[email protected] · web:www.accutemp.net
GE
D
D
G
F
G
G
8415 N. Clinton Park
AT1T-3595
Title:
Rev.Drawing No.: ATMOSPHERIC
Fort Wayne, IN 46825
G
SCHEMATIC, STEAMER,
AccuTemp Products, Inc.
BRN
GRN
BLK
BLK
WHT
WHT
BLK
ZR5 275V
L3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-11 PHASE, 208V - 240V
(ATMOSPHERIC STEAMER)
YEL
RED
DK BRN
YEL
PNK
YEL
LOWWATER
YE
L
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WAT
ER
SEN
SOR
BO
ARD
GN
D
PRB
2
AUTO-FILL OPTION ONLY
K2
K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
BLK
L1
SSR
3 +4 -
T1
R2 R3
HEATING ELEMENTS
R1BLK
WHT
BLK
WHT/BRN
2
1
3
4
5
6
VIO
BRN
THE
RM
AL
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YE
L
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
RE
D
RE
D
PRTD
KEY INPUT ANNUNCIATOR
BLK
RE
D
ON/OFF
TAN
1 2J2
1 2 3 4 5 6 J7
1 2J3
+24VGND
SENSOR INPUT
POWER INPUT
DIGITAL CONTROLLER
1 2J10
1.25 A
F2
1.25 A
F1
WH
T/BR
N
DO
OR
SW
WH
T/B
RN
FAULT ALARM
BLUYEL
MA
NU
AL
FILL
ON
LY
YE
L
MANUAL FILLONLY
Title:
Rev.Drawing No.:
AT1T-3595 ATMOSPHERIC
SCHEMATIC, STEAMER,
8415 N. Clinton ParkFort Wayne, IN 46825
G
AccuTemp Products, Inc.
G
D
D
E
F
G
G
G
RED
RED
HEATING ELEMENTS
BLK
WHT
R2
R3
R1
BLK
BLK
ZR2 275V
WHT
BLK
WHT
RED
ZR5 275VL3
CONTACTOR
ZR1 30V
L2
L1GRN
WHT
GXZ
Y
OR
N
WHT
AT1T-3595-23 PHASE, 208V - 240V
(ATMOSPHERIC STEAMER)
YEL
RED
YEL
BRN
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
6
BLK
L1
SS
R 1
3 +4 -T1
L1
SSR
2
3 +4 -T1
OR
N
BLK
RED
RED
WH
T/B
RN
BRN
THE
RM
AL
LIM
IT S
W3
VIO
ON/OFF
1 2J2
1 2 3 4 5 6 J7
+24VGND
SENSOR INPUT
POWER INPUT
DIGITAL CONTROLLER
RE
D
RE
D
PRTD
1 2J3
1 2J10
BLK
RE
D
WH
T/BR
N
DO
OR
SW
WH
T/B
RN
DK BRN
PNK
YEL
LOWWATER
YEL
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYEL
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PRB
1
WA
TER
SE
NS
OR
BO
AR
DG
ND
PRB
2
AUTO-FILL OPTION ONLY
K2
K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YE
L
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
TAN
FAULT ALARM
BLU
YEL
MA
NU
AL
FILL
ON
LY
YEL
MANUAL FILLONLY
G
D
D
E
F
G
G
G
G
Title:
Rev.Drawing No.:
AT1T-3595 ATMOSPHERIC
SCHEMATIC, STEAMER,
8415 N. Clinton ParkFort Wayne, IN 46825
AccuTemp Products, Inc.
RED
BLK
GRN
ZR2275V
WHT
WHT
GXZ
Y
RED
ZR5275V
BLK
WHT
RED
WHT
OR
N
WH
T/B
RN
OR
N
L1
SS
R 3
3 ~4 ~T1
L1
SS
R 2
3 ~4 ~T1
L1
SS
R 1
3 ~4 ~T1BLK
RED
RED
WHT
WHT
BLK
L3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-53 PHASE, 208V 15 – 17KW
(ATMOSPHERIC STEAMER)
WHT
BLK
YEL
RED
BRN
YEL
BRN
THE
RM
AL
LIM
IT S
W3
VIO
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
BLK
HEATING ELEMENTS
R2
R1
R3
3
2
4
5
6
1
WHT/BRN
ON/OFF
1 2J2
1 2 3 4 5 6 J7
+24VGND
SENSOR INPUT
POWER INPUT
DIGITAL CONTROLLER
RE
D
RED
PRTD
1 2J3
1 2J10
BLK
RE
D
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
DK BRN
PNK
YEL
LOWWATER
YE
L
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N.
C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WA
TER
SEN
SOR
BO
AR
DG
ND
PRB
2
AUTO-FILL OPTION ONLY
K2
K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YE
L
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C.
CO
M
8
5
23
6
TAN
FAULT ALARM
BLUYE
L
MA
NU
AL
FILL
ON
LY
YEL
MANUAL FILLONLY
8415 N. Clinton Park
Title:
Rev.Drawing No.:
AT1T-3595 ATMOSPHERIC
SCHEMATIC, STEAMER,
Fort Wayne, IN 46825
G
AccuTemp Products, Inc.
G
D
D
E
F
G
G
G
RED
BLU or ORN
WH
T
BRN
WHT
BLK
BLK
GRY
GRN/YEL
G L1
L3L2N
REDR2
R1
HEATING ELEMENTS
R3
BLK
ZR5 550VL3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-33 PHASE, 380V - 415V
(ATMOSPHERIC STEAMER)
ZR5 550V
YEL
RED
YEL
BRN
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
6
BLK
L1
SSR
1
3 +4 -
T1L1
SSR
2
3 +4 -T1
OR
N
BLK
RED
RED WHT/BRN
BRN
THER
MAL
LI
MIT
SW
3VI
O
ON/OFF
1 2J2
1 2 3 4 5 6 J7
+24VGND
SENSOR INPUT
POWER INPUT
DIGITAL CONTROLLER
RED
RED
PRTD
1 2J3
1 2J10
BLK
RED
WH
T/BR
N
DO
OR
SW
WH
T/B
RN
DK BRN
PNK
YEL
LOWWATER
YEL
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYEL
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WA
TER
SE
NS
OR
BO
ARD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YEL
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
TAN
FAULT ALARM
BLUYE
L
MAN
UAL
FI
LLO
NLY
YEL
MANUAL FILLONLY
G
D
D
E
F
G
G
G
Title:
Rev.Drawing No.:
AT1T-3595 ATMOSPHERIC
SCHEMATIC, STEAMER,
8415 N. Clinton ParkFort Wayne, IN 46825
G
AccuTemp Products, Inc.
BLK
R2 R3
HEATING ELEMENTS
R1BLK
WHT
BRN
BLU
GRN/YEL
G L1
N
BLK
WHT
2
1
3
4
5
EMI FILTER
BLK
L3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-61 PHASE, 230V
(ATMOSPHERIC STEAMER)
ZR2 275V
YEL
RED
YEL
BRN
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
L1
SSR
1
3 +4 -
T1
BRN
THER
MAL
LI
MIT
SW
3
VIO
ON/OFF
1 2J2
1 2 3 4 5 6 J7
+24VGND
SENSOR INPUTPOWER
INPUT
DIGITAL CONTROLLER
RED
RED
PRTD
1 2J3
1 2J10
BLK
RED
BLK
WH
T/B
RN
DO
OR
SW
WH
T/BR
N
DK BRN
PNK
YEL
LOWWATER
YEL
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYEL
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WAT
ER
SE
NSO
R B
OA
RD
GN
D
PRB
2
AUTO-FILL OPTION ONLY
K2K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YEL
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
TAN
FAULT ALARM
BLU
YEL
MAN
UAL
FI
LLO
NLY
YEL
MANUAL FILLONLY
G
D
D
E
F
G
G
G
Title:
Rev.Drawing No.:
AT1T-3595 ATMOSPHERIC
SCHEMATIC, STEAMER,
8415 N. Clinton ParkFort Wayne, IN 46825
G
AccuTemp Products, Inc.
REDBLU
or O
RN
BRN
ZR2550V
WHT
BLK
BLK
GRY
ZR5550V
GRN/YEL
G L1
L3L2N
RED
BLK
L1
SS
R 1
3 +4 -
T1L1
SSR
2
3 +4 -
T1
OR
N
BLK
R2
R1
HEATING ELEMENTS
R3BLK
WHT
RED
2
1
3
4
5
EMI FILTER
BLK
L3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-73 PHASE CE, 380 - 415V
(ATMOSPHERIC STEAMER)
YEL
RED
YEL
BRN
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
BLK
WHT
BRN
THER
MA
L LI
MIT
SW
3
ON/OFF
1 2J2
1 2 3 4 5 6 J7
+24VGND
SENSOR INPUT
POWER INPUT
DIGITAL CONTROLLER
RE
D
RE
D
PRTD
1 2J3
1 2J10
BLK
RED
WH
T/BR
N
DO
OR
SW
WH
T/B
RN
2
1
3
4
5
DK BRN
PNK
YEL
LOWWATER
YE
L
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WAT
ER
SEN
SOR
BO
ARD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
*DK BRN
*BLU
VIO
VIO
WH
T/G
RY
VIO
*H. W. LIMIT SW7
*BLK*BLK
VIO
YEL
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
TAN
FAULT ALARM
BLUYEL
MA
NU
AL
FILL
ON
LY
YE
L
MANUAL FILLONLY
H
B
C
C
D
E
F
H H
Title:
Rev.Drawing No.:
8415 N. Clinton Park
SCHEMATIC, GAS STEAMER
H
Fort Wayne, IN 46825
AT1T-3736
AccuTemp Products, Inc.
BR
N
AT1T-3736-1120V-240V
(GAS STEAMER)
YEL
OR
N
DK BRN
PNK
YEL
FILLW. VLV.
ZR3 38V
*AUTO-FILL ONLY
YE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1L2
PR
B 1
WA
TER
SE
NSO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5J6
J7J8
J9
J1 J2J3 J4
HIG
H L
IMIT
LOW
LIM
IT
DK BRN
*BLU
VIO
WH
T/G
RY
VIO
VIO
YEL
LOWWATER
YE
L
HIGHWATER
OVERTEMP
CH
AM
BER
PR
ESS
SW
WH
T/BR
N
DO
OR
SW
WH
T/B
RN
VIO
1 2J2
POWER INPUT
DIGITAL CONTROLLER
ON/OFF
1 2 3 4 5 6 J7
+24VGND
RE
D
RE
D
PRTD
1 2J3
SENSOR INPUT
BLK RED
1 2J10
PROBE AND GROUND WIRES MUST BE
TWISTED TOGETHER FOR EMI PROTECTION
RED
THER
MA
L LI
MIT
SW
3
M
FAN
BLK
GR
N
WHT BLK
3.0 A
F1
2
1
3
BLU
YEL
RED
YEL
BLK
BLK
WHT
N.O.
N.C.
COM
7
4
1
N.O.
N.C.
COM
8
5
2
3
6
RLY 2 DC
COIL
RED/WHT
240V
208V
120V
COM
AT0A-2779-2
24V
RED
ORN
TAN
YEL
ORN
HV IGNITORSENSOR PROBE
BURNER
RED
GRN
TIM
E D
ELA
YR
ELA
Y 1
-5 S
EC
-B
RN
ZR1
38VZR
2 38V PV
MV
GAS VALVE
ENRICHMENT VALVE
FAN PRESS SWLT BLU
TH PS
W V1 N
C IN
D L1 24 V
2 GN
D S
1 V
AC
SPARK
MO
DU
LEFLA
ME
S
EN
SE
+
FLAM
E
SEN
SE
-
MUST USE A SUPPRESSION TYPE IGNITION CABLE FOR EMI
PROTECTION
LT BLU
YE
L
*H. W. LIMIT SW7
*BLK*BLK
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
RLY 1 AC
COIL
TIME DELAY RELAY 2-4 SEC-
ZR4
38V
FAULT ALARM
BLU
YEL
MANUAL FILL ONLY
YEL
TAN
MANUAL FILL ONLY
E
F
D
D
Title:
AT1T-3595
8415 N. Clinton Park
ATMOSPHERIC
Fort Wayne, IN 46825
SCHEMATIC, STEAMER,
F
AccuTemp Products, Inc.
BRN
GRN
BLK
BLK
WHT
WHT
BLK
ZR5
275V
L3
CONTACTOR
ZR1
30V
L2
L1
OR
N
WHT
AT1T-3595-11 PHASE, 208V - 240V
(ATMOSPHERIC
STEAMER)
YEL
RED
DK BRN
YEL
PNK
YEL
LOW
WATER
HIGH
WATER
OVER
TEMP
FILL
W. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLU
GR
Y
GRY
WH
T/G
RY
YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
BLK
L1
SS
R
3 +
4 -
T1
R2 R3
HEATING ELEMENTS
R1BLK
WHT
BLK
WHT/BRN
2
1
3
4
5
6
VIO
BRN
TH
ER
MA
L
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L
WHY/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
RE
D
RE
D
PRTD
KEY INPUT
ANNUNCIATOR
BLK
RE
D
ON/
OFF
VIO
1 2
J2
1 2 3 4 5 6
J71 2
J3
+24V
GND
SENSOR
INPUTPOWER INPUT
DIGITAL
CONTROLLER
1 2
J10
1.25 A
F2
1.25 A
F1
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT
ALARM
BLU
YE
L
MA
NU
AL
FIL
L
ON
LY
MANUAL FILL ONLY
: Drawing No.:
SP8024-1108
Title:
Rev.
AT1T-3595 F
SCHEMATIC, STEAMER, ATMOSPHERIC
AccuTemp Products, Inc.8415 N. Clinton Park
Fort Wayne, IN 46825
D
D
E
F
RED
RED
HEATING ELEMENTS
BLK
WHT
R2
R3
R1
BLK
BLK
ZR2 275V
WHT
BLK
WHT
RED
ZR5
275VL3
CONTACTOR
ZR1 30V
L2
L1GRN
WHT
G
XZ
Y
OR
N
WHT
AT1T-3595-23 PHASE, 208V - 240V
(ATMOSPHERIC
STEAMER)
YEL
RED
DK BRN
YEL
PNK
YEL
LOWWATER
HIGHWATER
OVERTEMP
FILL
W. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLU
BRN
GR
Y
GRY
WH
T/G
RY
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
6
BLK
L1
SS
R 1
3 +
4 -
T1
L1
SS
R 2
3 +
4 -
T1
OR
N
BLK
RED
RED
WH
T/B
RN
VIO
BRN
TH
ER
MA
L
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L
WHT/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
ON/OFF
VIO
1 2
J2
1 2 3 4 5 6
J7
+24V
GND
SENSOR
INPUTPOWER
INPUT
DIGITAL
CONTROLLER
RE
D
RE
D
PRTD
1 2
J3
1 2
J10
BLK
RE
D
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT ALARM
BLU
YE
L
MA
NU
AL
FIL
LO
NLY
MANUAL FILL ONLY
Drawing No.:
SP8024-1108
D
D
E
F
Title:
Rev.
AT1T-3595 F
SCHEMATIC, STEAMER, ATMOSPHERIC
AccuTemp Products, Inc.8415 N. Clinton Park
Fort Wayne, IN 46825
RED
BLK
GRN
ZR2
275V
WHT
WHT
G
XZ
Y
RED
ZR5
275V
BLK
WHT
RED
WHT
OR
N
WH
T/B
RN
OR
N
L1
SS
R 3
3 ~
4 ~
T1
L1
SS
R 2
3 ~
4 ~
T1
L1
SS
R 1
3 ~
4 ~
T1
BLK
RED
RED
WHT
WHT
BLK
L3
CONTACTOR
ZR1
30V
L2
L1
OR
N
WHT
AT1T-3595-5
3 PHASE, 208V 15 – 17KW
(ATMOSPHERIC
STEAMER)
WHT
BLK
YEL
RED
DK BRN
VIO
BRN
YEL
PNK
YEL
LOW
WATERHIGH
WATEROVER
TEMP
FILL
W. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLU
GR
Y
GRY BRNWH
T/G
RY
TH
ER
MA
L
LIM
IT S
W3
VIO
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
BLK
HEATING ELEMENTS
R2
R1
R3
3
2
4
5
6
1
WHT/BRN
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L WHT/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
ON/
OFFV
IO
1 2
J2
1 2 3 4 5 6
J7
+24V
GND
SENSOR
INPUTPOWER
INPUT
DIGITAL
CONTROLLER
RE
D
PRTD
1 2
J3
1 2
J10
BL
K
RE
D
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT
ALARM
BL
U
YE
L
MA
NU
AL
FIL
L
ON
LY
MANUAL FILL ONLY
Drawing No.:
SP8024-1108
Title:
Rev.
AT1T-3595 F
SCHEMATIC, STEAMER, ATMOSPHERIC
AccuTemp Products, Inc.8415 N. Clinton Park
Fort Wayne, IN 46825
D
D
E
F
RED
RED
R2
R1
R3BLK
ZR2
550V
WHT
BLK
WHT
RED
ZR5
550V
GRN
G
XZ
Y
BLK
L3
CONTACTOR
ZR1
30V
L2
L1
OR
N
WHT
AT1T-3595-4
3 PHASE, 440V - 480V
(ATMOSPHERIC
STEAMER)
YEL
RED
DK BRN
YEL
PNK
YEL
LOW
WATER
HIGH
WATER
OVER
TEMP
FILL
W. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLU
GR
Y
GRY BRN
WH
T/G
RY
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
6
L1
SS
R 1
3 +
4 -
T1
L1
SS
R 2
3 +
4 -
T1
ORN
BLK
HEATING ELEMENTS
BLK
RED
RED WHT/BRN
VIO
BRN
TH
ER
MA
L
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L
WHT/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
ON/
OFF
VIO
1 2
J2
1 2 3 4 5 6
J7
+24V
GND
SENSOR
INPUT
POWER
INPUT
DIGITAL
CONTROLLER
RE
D
RE
D
PRTD
1 2
J3
1 2
J10
RE
D
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT
ALARM
BL
U
YE
L
MA
NU
AL
FIL
L
ON
LY
MANUAL FILL ONLY
Drawing No.:
SP8024-1108
Title:
Rev.
AT1T-3595 F
SCHEMATIC, STEAMER, ATMOSPHERIC
AccuTemp Products, Inc.8415 N. Clinton Park
Fort Wayne, IN 46825
D
D
E
F
BLK
R2 R3
HEATING ELEMENTS
R1BLK
WHT
BRN
BLU
GRN/YEL
GL1
N
BLK
WHT
2
1
3
4
5
EMI FILTER
BLK
L3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-61 PHASE, 230V
(ATMOSPHERIC STEAMER)
ZR2
275V
YEL
RED
DK BRN
YEL
PNK
YEL
LOWWATER
HIGHWATER
OVERTEMP
FILLW. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLU
GR
Y
GRY BRN
WH
T/G
RY
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
L1
SS
R 1
3 +
4 -
T1
VIO
BRN
TH
ER
MA
L
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L
WHT/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
ON/
OFF
VIO
1 2J2
1 2 3 4 5 6 J7
+24V
GND
SENSOR INPUT
POWER
INPUT
DIGITAL
CONTROLLER
RE
D
RE
D
PRTD
1 2J3
1 2J10
BL
K
RE
D
BLK
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT ALARM
BL
U
YE
L
MA
NU
AL
FIL
L
ON
LY
MANUAL FILL ONLY
Drawing No.
SP8024-1108
D
D
E
F
Title:
Rev.
AT1T-3595 F
SCHEMATIC, STEAMER, ATMOSPHERIC
AccuTemp Products, Inc.8415 N. Clinton Park
Fort Wayne, IN 46825
RED
BLU or ORN
WH
T
BRN
WHT
BLK
BLK
GRY
GRN/YEL
GL1
L3
L2N
RED
R2
R1
HEATING ELEMENTS
R3
BLK
ZR5
550VL3
CONTACTOR
ZR1 30V
L2
L1
OR
N
WHT
AT1T-3595-3
3 PHASE, 380V - 415V(ATMOSPHERIC
STEAMER)
ZR5
550V
YEL
RED
DK BRN
YEL
PNK
YEL
LOW
WATERHIGH
WATER
OVER
TEMP
FILL
W. VLV.
ZR7 275V
*AUTO-FILL ONLYYE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
*DK BRN
*BLUG
RY
GRY BRN
WH
T/G
RY
1.25 A
F2
1.25 A
F1YEL
BRN
480V
440V
240V
208V
COM
AT0E-2662-5
24V
2
1
3
4
5
6
BLK
L1
SS
R 1
3 +
4 -
T1
L1
SS
R 2
3 +
4 -
T1
OR
N
BLK
RED
RED WHT/BRN
VIO
BRN
TH
ER
MA
L
LIM
IT S
W3
VIO
*H. W. LIMIT SW7
*BLK*BLK
GR
Y
GR
Y
YE
L
WHT/GRY
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
ON/
OFFV
IO
1 2
J2
1 2 3 4 5 6
J7
+24V
GND
SENSOR
INPUTPOWER INPUT
DIGITAL
CONTROLLER
RE
D
RE
D
PRTD
1 2
J3
1 2
J10
BL
K
RE
D
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
FAULT
ALARM
BL
U
YE
L
MA
NU
AL
FIL
L
ON
LY
MANUAL FILL ONLY
Drawing No.:
SP8024-1108
F
B
C
C
G D
E
D
AT1T-3736C
Title:
Rev.Drawing No.:Size:
SCHEMATIC, GAS STEAMER
Fort Wayne, IN 468258415 N. Clinton Park
G
AccuTemp Products, Inc.
BR
N
AT1T-3736-1
120V-240V(GAS STEAMER)
YEL
OR
N
DK BRN
PNK
YE
L
FILL
W. VLV.
ZR3 38V
*AUTO-FILL ONLY
YE
L
GRN
LT BLU
ORN
N.O
.N
.C.
CO
M
N.O
.N
.C.
CO
M
L1
L2P
RB
1
WA
TE
R S
EN
SO
R B
OA
RD
GN
D
PR
B 2
AUTO-FILL OPTION ONLY
K2
K1
J5
J6
J7
J8
J9
J1
J2
J3
J4
HIG
H L
IMIT
LO
W L
IMIT
DK BRN
*BLU
GR
Y
VIO
WH
T/G
RY
VIO
VIO
YEL
WHY/GRY
LOWWATER
YE
L
HIGHWATER
OVERTEMP
GRY
CH
AM
BE
R P
RE
SS
SW
WH
T/B
RN
DO
OR
SW
WH
T/B
RN
VIO
1 2J2
POWER INPUT
DIGITAL
CONTROLLER
ON/OFF
1 2 3 4 5 6 J7
+24V
GND
RE
D
RE
D
PRTD
1 2J3
SENSOR INPUT
BL
K
RE
D
1 2J10
PROBE AND GROUND
WIRES MUST BE TWISTED TOGETHER
FOR EMI PROTECTION
RED
TH
ER
MA
L
LIM
IT S
W3
M
FAN
BLK
GR
N
WHT BLK
3.0 A
F1
2
1
3
BLU
YEL
RED
YEL
BLK
BLK
WHT
N.O.
N.C.
COM
7
4
1
N.O.
N.C.
COM
8
5
2
3
6
RLY 2 DC
COIL
RED/WHT
240V
208V
120V
COM
AT0A-2779-2
24V
RED
ORN
TAN
YEL
ORN
HV IGNITOR
SENSOR PROBE
BURNER
RED
GRN
TIM
E D
EL
AY
RE
LA
Y 1
-5 S
EC
-B
RN
ZR
1
38V
ZR
2
38
V PV
MV
GAS VALVE
ENRICHMENT
VALVE
FAN PRESS SW
LT BLU
TH
PS
W V
1 N
C IN
D L
1 2
4 V
2 G
ND
S1
V
AC
SP
AR
K
MO
DU
LE
FLA
ME
S
EN
SE
+
FLA
ME
S
EN
SE
-
MUST USE A SUPPRESSION
TYPE IGNITION CABLE FOR EMI PROTECTION
LT BLU
YE
L
*H. W. LIMIT SW7
*BLK
*BLK
GR
Y
N.O
.
N.C
.
CO
M7
41 N.O
.
N.C
.
CO
M
8
5
23
6
RLY 1AC
COIL
TIME DELAY
RELAY 2-4 SEC-
ZR
4
38V
FAULT ALARM
BL
UYEL
MANUAL FILL
ONLY
MANUAL FILL ONLY
MANUAL FILL ONLY