Page 1: SBC Introduction To Co Gen

CTI, 20 June 2011

Co-gen/CHP & Tri-gen Supply-Side Efficiency

Sustainable Business Consulting Pty LtdLevel 32, 101 Miller Street, North Sydney 2060P: 1300 102 195 | F: +61 2 8079 6101www.sustainablebizconsulting.com.au ACN 140 233 932 | ABN 46 506 219 241

Accredited by the NSW Government – On the panel of preferred suppliers

Page 2: SBC Introduction To Co Gen

Inputs and Outputs

The Flow of Energy

Page 3: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 320 June 2011

That much input

That much useful output

Page 4: SBC Introduction To Co Gen

INPU

TS

OU

TP

UT

AutomotiveDiesel Oil

560 kL ( 2,016 GJ )

Waste Heat 1,649

GJ

Engine Losses1,258 GJ

(Friction, Noise, Vibration)

Standby / Idle347 GJ

Hydraulics / Pneumatics 44 GJ

LOSSES

Wallaby Downs Mining OperationOre Haulage Surface Storage to ROM

Sanki Diagram - (Simplified Energy Flows)

Driveline Losses113 GJ

Aerodynamic Drag 52 GJ

Rolling Resistance 85 GJ

Inertia,(Acceleration Braking)

117 GJ

UsefulEnergy 117 GJ

OperatingPractices

Opportunity

TechnologyOpportunity

Mining operation example – energy is being used inefficiently

Out of all this input…

… we only get this much useful energy

Page 5: SBC Introduction To Co Gen

Making the Energy Input Smaller…

Page 6: SBC Introduction To Co Gen

This presentation will focus on Co-gen and Tri-gen

…Supply-side Efficiency

Page 7: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 720 June 2011

Power and heat generation

Traditional

By-product = heat

Sep. fuels for power & heat prod.

Centralised

Co-gen

Heat is captured

for heating

Single fuel source

Distributed

Page 8: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 820 June 2011

Traditional versus Co-gen (= CHP)

Coal-fired power stations typically only convert 30-40 % of their fuel energy into electricity

Page 9: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 920 June 2011

Page 10: SBC Introduction To Co Gen

Example: District Heating

Co-gen is Not New

Page 11: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1120 June 2011

Example for district heating – New York City

Approximately 30% of the steam system’s installed capacity and 50% of the annual steam generated comes from co-generation The district heating system takes steam and carries it under the streets of Manhattan to heat, cool, or supply power to high rise buildings and businesses.

Page 12: SBC Introduction To Co Gen

Fuels Used in Co-gen

Page 13: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1320 June 2011

Co-gen can use a variety of fuels

No oil in co-gen3 Most common:

Page 14: SBC Introduction To Co Gen

Small and Large Scale

What Does a Co-gen Plant Look Like?

Page 15: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1520 June 2011

Co-gen: Industrial application

Page 16: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1620 June 2011

Co-gen example at hotel

Luxury resort utilises cogeneration to provide power and hot water to residents and laundry services

Page 17: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1720 June 2011

Rice husk co-gen plant

Page 18: SBC Introduction To Co Gen

Co/Tri-gen in Australia

Page 19: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 1920 June 2011

Coopers brewery cogeneration project

Page 20: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2020 June 2011

Coopers video on co-gen

http://www.youtube.com/v/psSaSxrvrWY&hl=en_GB&fs=1

Page 21: SBC Introduction To Co Gen

Applicability and Benefits

Page 22: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2220 June 2011

Applicability

Organisation has need for both power and heat/steam Load patterns of both ideally stableLong operating hoursPrice of grid is highOrganisation needs reliable power supplyCost savingsLower emissions are needed (lower carbon footprint, better NABERS rating, etc.)

Page 23: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2320 June 2011

Benefits

Reduced energy billsAdditional profit from selling surplus energy back to the gridIncreased security of energy supply (blackouts, brownouts,…)No intermittency issuesLess carbon emittedMuch more efficientLess transmission and distribution lossesLess need for centralised power generationLess need for fuel

Page 24: SBC Introduction To Co Gen

Generation of Electricity, Heat, and Coolth

Tri-gen

Page 25: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2520 June 2011

Tri-gen

Electricity, heat, and coolthHeat is used in absorption chillers to create cooling2008: NAB uses a tri-gen plant to power and cool its data centre in Melbourne

20,000 t of carbon saved annuallyMeans NAB can spend less on carbon offsets (carbon neutrality!)Plant was pitched on a 5 year ROI, now shorter due to rise in electricity prices

Page 26: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2620 June 2011

Australia’s first tri-generation precinct for commercial buildings

Investa Property Group and Cogent, a subsidiary of Origin have established a tri-generation facility at Coca-Cola PlaceTri-gen supplies electricity, hot water and chilled water to the base buildingSurplus energy is exported via Ausgrid’s electricity distribution networkBenefits are shared with another Investa building (Deutsche Bank Place) through a virtual private energy network

COCA-COLA PLACE 40 MOUNT STREET NORTH SYDNEY

DEUTSCHE BANK PLACE 126 PHILLIP STREETSYDNEY

Page 27: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2720 June 2011

Tri-gen at 101 Miller Street, North Sydney

Sustainable Business Consulting’s office is in the 101 Miller Street Building

Page 28: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 2820 June 2011

Tri-generation in manufacturing

Tri-gen plant installed at Blackmore’s headquarters in WarriewoodPlate heat exchangers provide heating for the building space, lap pool and production heatingAbsorption chillers and heat exchangers fully integrated into the building heating, chilled and condenser water systemsPlant operates automatically during the peak and shoulder demand periods or during grid outages for emergency backupPlant supplies 772 kW peak electrical at 0.8 power factor

Page 29: SBC Introduction To Co Gen

Microgeneration

Page 30: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 3020 June 2011

Microgeneration at home

Page 31: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 3120 June 2011

Microgeneration – case study: Bluegen

BlueGen™’s maximum output is 2kW of electricity, with typical output being 1.5kW (good fit for the average home)The unit is as big as a dishwasherOperating on natural gas, BlueGen™ delivers a 60 % electrical efficiencyBlueGen™ can recover heat from the fuel cell for hot water - increases the total efficiency up to 85 %

Page 32: SBC Introduction To Co Gen

Co-gen on the MAC curve

Page 33: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 3320 June 2011

Marginal Abatement Cost Curve (for the USA)

Page 34: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 3420 June 2011

Australian MAC

It’s below the curve, so let’s do more of it!

Page 35: SBC Introduction To Co Gen

w w w . s u s t a i n a b l e b i z c o n s u l ti n g . c o m . a u | 3520 June 2011

Thanks For Attending This Presentation Sustainable Business Consulting

We are happy to help you further with your Carbon Management needs