![Page 1: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/1.jpg)
S&B NONTOX
Ammunition in Criminal
Casework
By Robert Berk
Illinois State Police
Forensic Science Center - Chicago
![Page 2: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/2.jpg)
Typical Gunshot Residue Analysis
Small Arms Percussion Primers
Explosive, initiator
Oxidizers
Fuel
Frictionators
Sensitizers
Binders
![Page 3: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/3.jpg)
Typical Gunshot Residue Analysis
Sinoxid “without rust” primer formulation
Lead styphnate
Tetrazene
Barium nitrate
Lead dioxide
Antimony trisulfide
Calcium silicide
![Page 4: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/4.jpg)
Typical Gunshot Residue Analysis
Bulk analysis
Elevated levels of the elements
In proper proportions
Particle analysis
Elemental composition
Morphology
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
Ba
Ba
Sb
Sb
Ba
Pb
Pb Pb
![Page 5: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/5.jpg)
Experience with Atypical Primers
1996 MRP (Magtech Recreational Products)
Primers purchased from CBC (Companhia
Brasileira de Cartuchos)
1987 – 1995 Various Calibers
Priming Mixture 5067
Barium nitrate 60%
Lead styphnate 38%
Tetrazene 2%
![Page 6: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/6.jpg)
Experience with Atypical Primers
Test results from typical case guns
Six different 9mm firearms test fired
1 or 2 shots under ideal test fire conditions
All test results inconclusive
Lack of elements/unacceptable ratios
Discharged cartridge cases antimony free
AAS and SEM/EDX
![Page 7: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/7.jpg)
Sellier and Bellot NONTOX
Promoted as “green” ammunition
Discharge a large amount of toxic heavy
metals… do not meet environmental
standards.
Sports, hunting, and practice shooting
Pb/Ba/Sb/Hg free
![Page 8: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/8.jpg)
U.S. Patent 6964287
“Non-toxic and non-corrosive ignition mixture”
Initiator
Nitroesters or nitramines
Sensitizer
Tetrazene or derivatives of tetrazoles
Oxidizers
Oxides and peroxides of metals
Fuel
Amorphous boron
![Page 9: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/9.jpg)
U.S. Patent 6964287
“Non-toxic and non-corrosive ignition mixture”
20 different examples of formulations
Tetrazene 25%
PETN 25%
Potassium nitrate 33.5%
Boron 6%
Nitrocellulose 0.5%
Glass 10%
![Page 10: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/10.jpg)
Availability
Sellier and Bellot recently purchased by CBC
7.65/.32 auto
9x19 and 9x21
.357 magnum
.38 special
.40 S&W
.45 ACP
Magtech Ammunition sole importers into US
9mm and 40 S&W available on-line
![Page 11: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/11.jpg)
Sellier and Bellot Nontox
Loss of PGSR Particles
Number of shots fired
To
tal
nu
mb
er
of
part
icle
s
![Page 12: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/12.jpg)
Fundamental Questions
How many discharges before false negative
test results?
How will a lead free primer affect the sodium
rhodizonate test for distance determinations?
![Page 13: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/13.jpg)
Typical Test Results
Automated test results
Antimony 44
Barium 362
Ba-Sb 22
Lead rich 19
Lead-Antimony 5
Lead-Barium 23
Pb-Ba-Sb The “X” Factor
![Page 14: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/14.jpg)
Eventual False Negative Results
X factor
X greater than 1
None of the particles are confirmed
Don’t meet identification criteria
Don’t meet threshold values
Red flag
X = 0
No particle meets the sorting criteria
Confident negative lab report
![Page 15: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/15.jpg)
ASTM E1588 - 10
“Gunshot Residue Analysis by Scanning
Electron Microscopy/Energy Dispersive X-
Ray Spectrometry”
![Page 16: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/16.jpg)
ASTM E1588 - 10
7. Data Analysis
7.1.3 Particles characteristic of GSR (that is,
most likely associated with the discharge of a
gun) will have the following elemental
composition:
7.1.3.1 Lead, antimony, barium
![Page 17: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/17.jpg)
Characteristic PGSR Particle
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
Ba
Ba
Sb
Sb
PbPb
Pb
Ba
Residue from a NONTOX discharge
![Page 18: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/18.jpg)
Doesn’t Meet Criterion
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550Ba
Sb
Sb
Pb
Pb
Pb
Ba
Al
Ba
Sb
Ba
Residue from NONTOX discharge
![Page 19: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/19.jpg)
ASTM E1588 - 10
7. Data Analysis
7.1.3.2 It is common for additional elements
to become incorporated into particles
containing these elements. (Pb/Sb/Ba)
Potassium
![Page 20: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/20.jpg)
Non-verified PGSR Particle
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
Ba
Ba
Sb
PbPb
Pb
Si Sb
Cu
Al
Cu
K
Residue from NONTOX discharge
![Page 21: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/21.jpg)
Airbag Residue Particle
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
PbPb
Pb
Ba
Ba
Ba
SbSb
KSi
Cl
Al 2003 Ford van passenger’s side
![Page 22: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/22.jpg)
Test Fire Technique
Hands in “normal” condition
Relatively clean
Ideal Sampling Conditions
Very thorough
“Willing” suspect
Factors not taken into consideration
Particle loss/time
Environmental loss
![Page 23: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/23.jpg)
Series 1: 9mm single shot
Ruger model P89
1 round Sinoxid discharged as baseline.
1 NONTOX fired daily
Left hand sampled before as background
Right hand sampled immediately after
discharge
![Page 24: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/24.jpg)
Test Fire Results
Typical PGSR particles
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
Pb
Pb
Ba
BaSb
Sb
Pb
Ba
BaResidue from NONTOX discharge
![Page 25: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/25.jpg)
Test Fire Results
Clusters
Large, brittle conglomerates of particles
Source of sequential PGSR particles
![Page 26: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/26.jpg)
Particle Clusters
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
BaBa
Sb
Sb
Pb Pb
Pb
K
Cu
Cu
Sb
Ba
![Page 27: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/27.jpg)
Particle Clusters
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
PbPb
Pb
Ba
Ba
Sb
Sb
BaCu
Cu
Si
K
![Page 28: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/28.jpg)
Particle Clusters
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
Ba
Ba
Ba
PbPb
Pb
Sb
Sb
Cu
Cu
K
Al
Zn
![Page 29: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/29.jpg)
Last 10 Test Fires
9mm NONTOX
0
100
200
300
400
500
600
Total number of shots fired
Dete
cte
d c
hara
cte
risti
c P
GS
R p
art
icle
s
38 39 40 41 42 43 44 45 46 47
![Page 30: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/30.jpg)
Last 10 Test Fires
9mm NONTOX
0
10
20
30
40
50
60
70
80
90
100
Total number of shots fired
Veri
fied
ch
ara
cte
risti
c P
GS
R p
art
icle
s
38 39 40 41 42 43 44 45 46 47
![Page 31: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/31.jpg)
Last 10 Test Fires
Load = consistent PGSR particles/area
Red flag
9mm NONTOX
0
2
4
6
8
10
12
14
16
18
20
Total number of shots fired
Co
nsis
tan
t p
art
icle
s/a
rea a
naly
zed
38 39 40 41 42 43 44 45 46 47
![Page 32: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/32.jpg)
Last 10 Test Fires
9mm NONTOX
0
200
400
600
800
1000
1200
1400
1600
1800
2000
Total number of shots fired
Nu
mb
er
of
lead
part
icle
s d
ete
cte
d
38 39 40 41 42 43 44 45 46 47
![Page 33: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/33.jpg)
Cartridge Components
Brass primer cup Nickel anvil
![Page 34: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/34.jpg)
Cartridge Component
Potassium coating on smokeless powder
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550K
K
![Page 35: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/35.jpg)
Cartridge Component
Potassium coating on smokeless powder
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550K
K
![Page 36: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/36.jpg)
Cartridge Component
Particulate lead in smokeless powder
Present in 9mm, .40 S&W, 38 spl.
keV0 1 2 3 4 5 6 7 8 9 10 11 12
counts
0
510
1020
1530
2040
2550
PbPb
Pb
![Page 37: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/37.jpg)
Series 2: 40 S&W 4 shot bursts
40 Smith and Wesson model SW40V
1 Sinoxid discharged
1 NONTOX discharged as baseline
4 NONTOX discharged daily
Left hand sampled as background
Right hand sampled immediately after
discharge
![Page 38: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/38.jpg)
Last 20 Test Fires
40 S&W NONTOX
0
10
20
30
40
50
60
70
80
Total number of shots fired
Dete
cte
d c
hara
cte
risti
c P
GS
R p
art
icle
s
46-49 50-53 54-57 58-61 62-65
![Page 39: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/39.jpg)
Last 20 Test Fires
40 S&W NONTOX
0
5
10
15
20
25
30
35
40
45
Total number of shots fired
Veri
fied
ch
ara
cte
risit
c P
GS
R p
art
icle
s
46-49 50-53 54-57 58-61 62-65
![Page 40: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/40.jpg)
Last 20 Test Fires
40 S&W NONTOX
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
Total number of shots fired
Co
nsis
tan
t p
art
icle
s/a
rea a
naly
zed
46-49 50-53 54-57 58-61 62-65
![Page 41: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/41.jpg)
Last 20 Test Fires
40 S&W NONTOX
0
50
100
150
200
250
300
Total number of shots fired
Nu
mb
er
of
lead
part
icle
s d
ete
cte
d
46-49 50-53 54-57 58-61 62-65
![Page 42: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/42.jpg)
Series 3: 38 special 5 shot capacity
Ruger model SP101
1 Sinoxid discharged
Gun “cleaned” by Intern
Dust-off, paper towels, Q-tips
1 NONTOX discharge as baseline
5 NONTOX fired daily
Left hand sampled as background
Right hand sampled immediately after
discharge
![Page 43: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/43.jpg)
Last 20 Test Fires
.38 special NONTOX
0
200
400
600
800
1000
1200
1400
Total number of shots fired
Dete
cte
d c
hara
cte
risti
c P
GS
R p
art
icle
s
27-31 32-36 37-41 42-47
![Page 44: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/44.jpg)
Last 20 Test Fires
.38 special NONTOX
0
50
100
150
200
250
300
350
400
450
500
Total number of shots fired
Veri
fied
ch
ara
cte
risti
c P
GS
R p
art
icle
s
27-31 32-36 37-41 42-46
![Page 45: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/45.jpg)
Last 20 Test Fires
.38 special NONTOX
0
2
4
6
8
10
12
14
16
18
20
Total number of shots fired
Co
nsis
tan
t p
art
icle
s/a
rea a
naly
zed
27-31 32-36 37-41 42-46
![Page 46: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/46.jpg)
Last 20 Test Fires
.39 special NONTOX
0
100
200
300
400
500
600
Total number of shots fired
Nu
mb
er
of
lead
part
icle
s d
ete
cte
d
27-31 32-36 37-41 42-46
![Page 47: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/47.jpg)
Distance Determination
“A Versatile Technique for the Investigation of
GSR Patterns on Fabrics and Other Surfaces:
m-XRF” Berendes et al (BKA) JFS Sept 2006
“Nontox ammunition containing only
potassium as a detectable metallic
composition of the primer.”
Fired at 5 cm into target
![Page 48: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/48.jpg)
Distance Determination
“The Sodium Rhodizonate Test: A Chemically
Specific Chromophoric Test for Lead in
Gunshot Residues” Dillon (FBI) AFTE
Journal July 1990
“primarily due to the lead compounds typically
found in cartridge primer mixtures”
“bullet/barrel interactions”
![Page 49: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/49.jpg)
Distance Determination
![Page 50: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/50.jpg)
Distance Determination
![Page 51: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/51.jpg)
Distance Determination
No visible soot
No partially burnt smokeless powder
Atypical vaporous lead results
Problematic for Medical Examiners
Stippling and visual examinations
![Page 52: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/52.jpg)
Series 4: 9mm with multiple shots
Beretta Model 92D
Retired P.O.’s firearm
Not shot in 4+ years
150 shots fired rapidly
151st shot as test fire
Additional shots fired
Additional test fires
![Page 53: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/53.jpg)
Last 40 Test Fires
9mm NONTOX
0
5
10
15
20
25
30
35
Total number of shots fired
Dete
cte
d c
hara
cte
risit
c P
GS
R p
art
icle
s
151 161 171 172 181 191
![Page 54: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/54.jpg)
Last 40 Test Fires
9mm NONTOX
0
1
2
3
4
5
6
7
8
9
Total number of shots fired
Veri
fied
ch
ara
cte
risti
c P
GS
R p
art
icle
s
151 161 171 172 181 191
![Page 55: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/55.jpg)
Last 40 Test Fires
9mm NONTOX
0
0.5
1
1.5
2
2.5
3
3.5
4
Total number of shots fired
Co
nsis
tan
t p
art
icle
s/a
rea a
naly
zed
151 161 171 172 181 191
![Page 56: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/56.jpg)
Conclusions
Positive PGSR test results possible with
NONTOX ammunition
False negative PGSR test results are
possible with NONTOX in actual casework
Difficult to remove all “memory effect” from
weapon
Distance determinations may be problematic
![Page 57: S&B Nontox Ammunition in Criminal Casework · NONTOX ammunition False negative PGSR test results are possible with NONTOX in actual casework Difficult to remove all “memory effect”](https://reader035.vdocuments.site/reader035/viewer/2022071503/61232a59e035203d1f2a5590/html5/thumbnails/57.jpg)
Acknowledgements
ISP Forensic Science Command
ISP Research and Development Laboratory
Marc Pomerance – Firearms
Radson Muradpejohi – Summer Intern
Scott Rochowicz – Trace
Kellen Hunter - Firearms
Magtech Ammunition