sampling & sample preparation catalog...sampling and sample preparation are the key steps in...

126
Solid Phase Extraction SPE Disks 96 well plates SPE & Spin SPE Microelution & SPE Tips Passive sampling and associated products SAMPLING & SAMPLE PREPARATION CATALOG V24

Upload: others

Post on 03-Aug-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Solid Phase Extraction SPE Disks

96 well plates SPE & Spin SPE Microelution & SPE Tips

Passive samplingand associated products

SAMPLING & SAMPLE PREPARATION

CATALOG

V24

Page 2: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Page 3: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 3

Dear Customer

We are pleased to offer you our new catalog for SAMPLING & SAMPLEPREPARATION containing innovative solutions to help you to achieve yourgoals.

AFFINISEP is expert in making consumables for sample preparation andextraction techniques. We save you time by simplifying your workflowswith smart application-specific kits, ready to use pre-developed methods,and the highest level of scientific support for your selective extractionneeds. Our R&D team is fully committed to developing high qualityproducts that help you to get accurate information as quickly as possible;We provide knowledge and expertise to produce superior off-the-shelfconsumables and custom resins. Our manufacturing organizationsupported by highly skilled sales and support team is at your disposal tosatisfy you.

And particularly, we are committed to providing the best technicalsupport possible. Our in-house scientific team will work with you todevelop personalized solutions to fit your specific application. Fortechnical inquiries, please contact us by email:[email protected]

We are very thankful to hear all your feedbacks about our products,protocols and customer services by email to: [email protected]

Your satisfaction is our engine. Thank you to trust us!

Kaynoush NaraghiCEO

Page 4: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 4

Page 5: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

PRODUCT SELECTION GUIDE 8SOLID PHASE EXTRACTION SOLUTIONS 9

PRODUCTS PRESENTATIONSOLID PHASE EXTRACTION

FORMATS 13

SOLID PHASE EXTRACTION SOLUTIONS – Proteomics and biological applications 16AttractSPE™ Disks proteomics tools 17AttractSPE™ Disks Technology for microelution 19Focus on AttractSPE™ Disks proteomics tools 20AttractSPE™ Disks Tips – Stagetips 22AttractSPE™ Disks 96 plate for microelution 24AttractSPE™ Disks 96 plate – 1mL 25AttractSPE™ Disks Spin column for microextraction 26AttractSPE™ Disks Cartridges 29AttractSPE™ Disks BioMol to do your own tools 30

SOLID PHASE EXTRACTION SOLUTIONS – For simple to very complex matrices 31Quick look guide

READY TO USE SPECIFIC KITSAFFINIMIP®SPE (MOLECULARLY IMPRINTED POLYMER) AND DEDICATED APPLICATIONS 35

AFFINIMIP® SPE – CONCEPTS 36AFFINIMIP® SPE FOR ANALYTICAL PURPOSE 38

AFFINIMIP® SPE FOR MYCOTOXINS 39AFFINIMIP®SPE Multimyco LCMSMS for Multimycotoxins analyses 40AFFINIMIP®SPE FumoZON for Fumonisins and Zearalenone (simultaneously) 41AFFINIMIP®SPE Patulin 42AFFINIMIP®SPE Ochratoxin A 43AFFINIMIP®SPE Deoxynivalenol 44AFFINIMIP®SPE Zearalenone 45

TABLE OF CONTENTS

5

Page 6: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP®SPE Glyphosate for glyphosate, AMPA, glufosinate… 46AFFINIMIP®SPE Picolinic herbicides for Picloram, Aminopyralid, Clopyralid 47AFFINIMIP®SPE PAHs 48AFFINIMIP®SPE Tetracyclines 49AFFINIMIP®SPE Chloramphenicol 50AFFINIMIP®SPE Aminoglycosides 51AFFINIMIP®SPE Estrogens 52AFFINIMIP®SPE Bisphenols 53AFFINIMIP®SPE Zeranol residues 54AFFINIMIP®SPE Phenolics 55AFFINIMIP®SPE NNAL 56AFFINIMIP®SPE Amphetamines 57AFFINIMIP®SPE Catecholamines 58AFFINIMIP®SPE Metanephrines 59AFFINIMIP®SPE Tamoxifen 60AFFINIMIP®SPE Cannabis 61AttractSPE™ WAX-PFC for perfluorinated compounds 62AttractSPE™ Non-target screening 63AttractSPE™ Chelating for metal retention 63SilactSPE™ DAU (Drug of abuse use) & SilactSPE™ Organotins 64SPE for Polycyclic aromatic Hydrocarbons with AFFINIMIP®SPE PAHs, SilactSPE™

CN/SiOH & AttractSPE™ HLB 65SPE for the interferences removal – AttractSPE™ SAX-HCO3 & AttractSPE™ PS-H 66SPE for the interferences removal – AttractSPE™ PS-Ag & AttractSPE™ PS-Ba & SilactPE™

HydroxyApatite 67SPE FOR GENERAL METHODS

AttractSPE™ POLYMERIC-BASED SPE 68AttractSPE™ HLB - Hydrophilic Lipophilic Balance 71AttractSPE™ WAX - Weak Anion Exchange 72AttractSPE™ WCX - Weak Cation Exchange 73AttractSPE™ SAX - Strong Anion Exchange 74AttractSPE™ SCX - Strong Cation Exchange 75AttractSPE™ DVB - Reversed phase 76

Inorganic based SilactSPE™ CARTRIDGES 77SilactSPE™ C18 (end capped) & SilactSPE™ C18NEC (not end capped) 79SilactSPE™ C8 & SilactSPE™ Phenyl 80

TABLE OF CONTENTS

6

Page 7: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SilactSPE™ Silica & SilactSPE™ Cyano 81SilactSPE™ Amine (SiWAX) & SilactSPE™ PSA 82SilactSPE™ SiWCX & SilactSPE™ SiSCX 83SilactSPE™ SiSAX & SilactSPE™ Carbonate 84SilactSPE™ Florisil PR, SilactSPE™ Dry & SilactSPE™Na2SO4/ Florisil 85SilactSPE™ Alumina-Acidic, Neutral and Basic 86AttractSPE™ Carbon based SPE with AttractSPE™ carbon, AttractSPE™ carbon/Amine& AttractSPE™ carbon/PSA 87

AttractSPE™ On-Line SPE 88Filtration & Passthrough methodsAttractSPE™ SLE, AttractSPE™ LipRem, PROTEINS & LIPID REMOVAL; AttractFiltra™

SPE for the removal of proteins or lipids – AttractSPE™ LipRem & SilactSPE™ double 90fritted or single Fritted 91AttractSPE™ SLE for Supported Liquid Extraction 92AttractFiltra™ for membrane filter cartridge 93

QUECHERS AND EXTRACTION SALTS 94

WATER MONITORING SPE DISKS & PASSIVE SAMPLING 99AttractSPE™ DISKS 100

AttractSPE™ Disks Environment 103AttractSPE™ Disks Manifolds and accessories 104

PASSIVE SAMPLING SOLUTIONS – POCIS, SPATT, Chemcatcher 105Passive sampling product list 106

SPE ACCESSORIES 111AttractSPE™ Positive Pressure Manifold 112Vacuum SPE Manifold and ACCESSORIES 113

EXAMPLES OF SPE APPLICATIONS 115

CUSTOM-MADE PRODUCTS & PRIVATE LABEL SERVICES 122Custom-made products & Services 123Project development 124Private label services 125

ORDERING INFORMATION 126

TABLE OF CONTENTS

7

Page 8: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

PRODUCT SELECTION GUIDE

8

Sampling and sample preparation are the key steps in trace analysis foranalytical chemist. As specialist in this field, AFFINISEP supplies a completerange of solutions based on Solid Phase Extraction (SPE), passive samplingand filtration processes for automated, high-throughput or manual samplepreparation.

A multitude of chemical phases and formats are available for variousapplications. We offer a comprehensive range of SPE to give you all elementsto face the increasingly complex and diverse sample preparation challengesby:§ Simplify data analysis by removing interferences§ Increase sensitivity and reliability by enrichment of the analyte§ Obtain high and reproducible recovery yields from complex samples

Solid Phase Extraction SPE Disks Spin SPE

SPE TipsPassive

samplers (POCIS, SPATT)

96 well Plates SPE

Filtration columns

Dispersive SPE, Quechers SLE

SPE Manifolds and

Accessories

Page 9: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Solid Phase Extraction Solutions

9

2L - 500mL

• AttractSPE™ Disk

• Passive samplers: POCIS, SPATT,

Chemcatcher

200mL – 1mL

• AFFINIMIP® SPE

• AttractSPE™

• SilactSPE™

• Qcleanup™ Quechers

• AttractFiltra™ Filtration

• AttractSPE™ SLE

1000µl - 10µl

• AttractSPE™ Disks Tips – Stagetips

• AttractSPE™ Disks 96 well-plate SPE

• AttractSPE™ Disks Spin SPE

• AttractSPE™ Disks SPE cartridges

Samplevolume

Page 10: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 10

Solid phase extraction (SPE)AFFINIMIP®SPE, AttractSPE™ and SilactSPE™ are a powerful techniques toprovide a rapid and selective sample clean-up, a high recovery and theconcentration necessary for accurate quantitative analysis. Usually available as aSPE cartridge format with flange or without flange (Flangeless for someautomate applications)

SPE DisksAttractSPE™Disks are Solid Phase Extraction Disks for the extraction of a broadrange of contaminants. AttractSPE™Disks are thin and uniform SPE disks forretention of targeted analytes without any breakthrough. Attract SPE™Diskshave been diversified in two very different fields requiring their ownspecifications: Environment and Biomolecular analysis.

Passive sampling for microcontaminants or biotoxinsPassive sampling enables the monitoring of contaminants in water for a short tolong period (with an average field deployment of one month) for which nopower, maintenance and supervision is required. An average of theconcentration of collected contaminants (pesticides, drugs residues, biotoxins,PAHs, Glyphosate & AMPA…) is measured in the laboratory. AFFINISEP provides awide range of solutions for passive sampling for POCIS, SPATT, Chemcatcher forthe sampling of contaminants such as pesticides, drugs or biotoxins in water.

Filtration with Membranes or with fritsAttractFiltra™ is a filtration cartridge or 96-well plate based on the use ofmembrane for sample particles filtration using vaccuum manifold, gravity or SPEautomates. A broad range of membranes is available and can enable a broadrange of sample filtration. Double fritted cartridges are also available for proteinprecipitation.

Dispersive SPE - QuechersQcleanup™ dispersive SPE products are a mixture of Magnesium Sulfate, PSA,Black carbon or C18 used by QuEChERS method for the clean-up of fruits andvegetables during multiresidues pesticides analyses.

Supported Liquid Extraction (SLE)AttractSPE™SLE is Supported Liquid Extraction (a.k.a SLE) , an alternative to LLEto pass from an aqueous media to an organic media without emulsion formation.SLE is used to transfer hydrophobic molecules from water to an organic solvent.In addition, this process can be used for the removal of proteins or lipids.

PRODUCTS PRESENTATION

Page 11: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 11

Microextractions

For proteomics or genomics analysis, sample size is often a few microliters.However, sample preparation is required and sample preparation tools mustwork for such small sample size.Some sample preparation tools are presented below. They are based on theuse of AttractSPE™Disks as sorbent. Thanks to these densely packed beadsembedded in the disk, the volume of elution is reduced in comparison toclassical packed powder.

AttractSPE™ Disks Tips – StagetipsµSPE column designed by immobilizing a uniform disk inside a pipette tips (Stagetips).

AttractSPE™ Disks Spin SPESPE column designed by immobilizing a uniform disk inside a microcentrifugeSPE tube.

AttractSPE™ Disks 96 well-plate SPE96 SPE well plate designed by immobilizing a uniform disk

AttractSPE™ Disks SPE cartridgesSPE cartridges designed by immobilizing a uniform disk.

PRODUCTS PRESENTATION

Page 12: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 12

SPE PROCEDURE STEPS

1- Sample preparation: This step is necessary to obtain a loading solutioncompatible with retention condition in the SPE column. In case of solid matrices,this solution must also extract the compounds of interest from these matrices.2- Conditioning: The SPE cartridges are conditioned with the appropriated solventsto fully soak sorbent and enable further interactions between the analytes and thesorbent.3- Loading: the percolation solution is loaded through the SPE cartridge. Theanalyte must be retained in the column as well as unwanted compounds.4- Washing: interferences and unwanted compounds are washed off by usingappropriate solvents.5- Elution: The desired analyte is extracted from the SPE cartridge.

Retention Mechanism

SOLID PHASE EXTRACTION

•Based on polar-polar or dipole-dipole interactions betweenthe analyte and a non organic phase like silica.Normal phase

•Based on non polar- non polar interactions and Van derWaals dispersive forces. The sorbent is hydrophobic likepolymeric sorbent modified silica-based sorbent.

Reversed phase

•Uses electrostatic interaction between a charged sorbentand the ionic analyte. The sorbent is charged with theopposite charge of the analyte.

Ion-exchange

• Interact through reversed phase and ion exchangeretention mechanisms. Available as a polymeric sorbent(AttractSPE™ SAX, WAX, WCX or SCX) or as SilactSPE™.

Mixed-mode sorbents

•Highly selective based on forme and interaction of onemolecule or a familly of moleculesImprinted

Loading sample Washing Elution

SPE Sorbent

Conditioning

Concentratedand cleaned

sample

Page 13: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Formats

13

The choice of format is essential for a successfullanalysis.Our products are available under differentformats. We can provide as well other formatsunder request.If you need some support to identify the rightformat, please contact our technical support.

For any question, please contact us:[email protected]

Page 14: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

FORMATS

Open CartridgeFormats: 1mL, 3mL, 6mL, 15mL, 20mL, 60mL With flange or tablessMaterials: Polypropylene,glass (6mL)Frits: Polyethylene, PTFE , Glass fiberSorbents: powder or diskluer compatible

ReversibleCartridge

Formats: 0,7mL, 2mLMaterial: PolypropyleneFrit: PolyethyleneLuer compatible

LRC Cartridge

Luer compatibleFormats: 10mL

Material: PolypropyleneFrit: Polyethylene

Cartridge for AutomatesFormats: 1mL, 3mL, 6mLMaterial: PolypropyleneFrit: Polyethylene

On-line SPE CartridgeI.D: 2,1 and 4,6mmLength: 20mm

14

Page 15: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AVAILABLE

Dispersive SPE

96 Well-plates

Sorbents: powder or disks

SPE Tips

Spin SPE

Disks

Passive SamplersI.D: 54mmO.D.: 90mm

15

Page 16: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Solid Phase Extraction Solutions

16

1000µl - 10µl

• AttractSPE™ Disks SPE Tips –

Stagetips

• AttractSPE™ Disks Spin SPE

• AttractSPE™ Disks 96 well-plate SPE

• AttractSPE™ Disks SPE cartridges

Proteomics and

biological

applications

Page 17: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Spinnable, AutomatableHigh throughput HTS

Micro-SPE for MicroElution

17

AttractSPE™DisksProteomics, Biomarker discoveries

and Biological applications

Page 18: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ Disks Technology for microelution

18

AttractSPE™Disks are thin, dense, soft and uniform membranes basedchromatography for extraction/separation, purification and concentrationof analyte molecules.Thanks to their unique advantage, AttractSPE™Disks are useful forpurification of Very Small Sample Volumes in Proteomics, Genomics,Metabolomics, Bioanalysis, Biomarker discoveries and Biologicalapplications. They are applied for Spinnable, Automatable, High throughputmicroelution and nano elution.AttractSPE™Disks offer outstanding sample preparation efficiency andreproducibility of results. Since the diffusion distance between particles isminimized, adsorption is more efficient, and extraction can be accomplishedusing very low sorbent mass.These properties are giving to AttractSPE™Disks a significant improvementof mass transfer kinetics compared to traditional packed SPE particles. As amonolith disk, AttractSPE™Disks are self stand and require no frits forimmobilizing the column bed (unlike traditional SPE products) allowing100% recovery of the original sample volume.

• No need to frits or filters• Reduced dead volume• Small elution volumes• High sample recovery• Reduced time for eluate evaporation• Higher throughput• Channeling effects eliminated• Excellent reproducibility• Concentration of the sample

AttractSPE™Disk Advantages

Page 19: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ Disks Technology for microelution

19

AttractSPE™Disks can be used to miniaturize SPE for small operating volume

of fluid samples. 4 formats are available for microelution. Thanks to the

use of AttractSPE™Disks for all formats, then the change of format or the

scale up of the process is easy.

q AttractSPE™ Disks Tips – Stagetips and AttractSPE™ Disks 96 well-Plate for microelution

µSPE columns designed by immobilizing auniform disk inside a pipette tips (Stagetips perunit or as 96 well plate)

q AttractSPE™ Disks Spin ColumnsSPE column designed by immobilizing a uniform

disk inside a centrifuge SPE tube

q AttractSPE™ Disks 96 well-Plate96 SPE well plate designed by immobilizing a

uniform disk

q AttractSPE™ Disks CartridgesSPE cartridges designed by immobilizing a

uniform disk

Capacityof m

oleculesof interestincreasesCo

ncen

trat

ion

of m

olec

ules

of in

tere

stin

crea

ses

Page 20: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 20

AttractSPE™ Disk Tips, Spin, 96 plate and cartridges are tools forproteomic applications (fractionation and desalting ofpeptides/proteins) and for bioanalysis (small molecules cleanup).In order to give the most exhaustive applications, they areproposed with a large variety of sorbents (HLB, RPS, SDB, SCX, SAX,C8, C18…).

Focus on AttractSPE™ Disks proteomic tools

Advantages of AttractSPE™ Disk tools

•Removes interfering contaminants—significantly reduces signalsuppression and improves signal-to-noise ratios and sequencecoverage

•Simplifies optimization—processing yields high-quality spectra and iseffective for a variety of reverse-phase-compatible contaminates

•Robust—works with a wide variety of load volumes andconcentrations; no need to reduce sample volume before application

•Convenient—easy to handle and requires no special equipment toprocess multiple samples simultaneously (unlike tip-driven systemsthat require one sample to be processed at a time)

•Sensitive—special C18 resins allows excellent recovery percentages,even at low (sub-picomole) sample loads

A B C

A: one membraneB: Stacking of several membranes layersC: membrane used as filter for µm beads

Different combinations of SPE disks for requested applicationsAttractSPE™ Disks sorbents

•A broad variety of sorbents foreach required applications•Various formats: disks, spins, 96SPE plates, cartridges•One sorbent - several layers forincreased capacity•Several sorbents - stacking forcomplex applications•Disks used as filter forapplication requiring beads

Page 21: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ Disks chemistries

21

Sorbents for SPE Disks forbiomolecular applications Compatible with analytical methods

- C18 end-capped (C18 EC) for themost hydrophobiccompounds/peptides- C18 Not end-capped (C18 NEC) withthe best combination - large spectrumof interaction - capacity- C18 for the wider interactionspectrum (hydrophobic - hydrophilic)with compounds / peptides

- Desalting of peptides; fractionationof peptides at acidic and neutral pH- Drug extraction in biologicalsamples,

C8Desalting of large peptides andproteins; Usage as frits to retainbeads in a tip

Silica Purification of DNA

C4 Desalting of large peptides andproteins

SDB a.k.a PS-DVB Fractionation of peptides at basic pH

HLB: SDB with hydrophilicmoieties

Fractionation of peptidesExtraction of small molecules (drugs)in biological fluids

SDB – RPS: Sulfonic modified SDBsorbent

Desalting of peptides; fractionationof peptides

SAX : Anion exchange SDB Fractionation of peptides by salt orpH steps

SCX : Cation exchange SDB Fractionation of peptides by salt orpH steps

Page 22: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ Disks Tips – StageTips

22

AttractSPE™Disks Tips are spinnable and automatableTips for high throughput useful for peptide desalting,proteomics, small molecules screening and biomarkerdiscoveries and biological applications

Tip Volume (μL)

•200•300•500•1000

Resin Volume (μL)

•5•10•12•20•40•80•160•200

Resin:

•C18 300Å•C18 100Å•C8 100Å•C4 300Å•Strong Anion•Strong Cation•Weak Anion•Weak Cation•HLB•RPS

Application

•Desalting•PCR Purifcation kit

•GenomicPurification

•Fractionation•PlasmidPurification

•Bioanalysis…

To prepare high quality peptidesamples for LC-MS, it is veryimportant to ensure the overallquality of shotgun proteomicsexperiments. Peptide samplescollected after digestion usuallyneed to be cleaned to removesalts, possible gel pieces (for in-gel digested samples) orparticles (for in-solutiondigested samples), whichotherwise will damage the LCswitching valves or clog thecolumns.

Page 23: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks Tips – Stage Tips

23

Designation Description Reference – 200µl - 96/pk

Reference –1mL -96/pk

AttractSPE™ DisksTips C18

C18 membrane, 96/pk Tips-C18.T1.200.96

Tips-C18.T1.1000.96

AttractSPE™ DisksTips C18 EC

End-capped C18 membrane, 96/pk

Tips-C18EC.T1.200.96

Tips-C18EC.T1. 1000.96

AttractSPE™ DisksTips C18 NEC

Not end-capped C18 membrane, 96/pk

Tips-C18NEC.T1.200.96

Tips-C18NEC.T1.1000.9

6

AttractSPE™ DisksTips C8

C8 membrane, 96/pk Tips-C8.T1.200.96 Tips-C8.T1. 1000.96

AttractSPE™ DisksTips SDB

PS-DVB membrane, 96/pk

Tips-DVB.T1.200.96

Tips-DVB.T1. 1000.96

AttractSPE™ DisksTips SDB - RPS

Modified DVB membrane, 96/pk

Tips-RPS.T1.200.96

Tips-RPS.T1. 1000.96

AttractSPE™ DisksTips SAX

SAX membrane, 96/pk Tips-SAX.T1.200.96

Tips-SAX.T1. 1000.96

AttractSPE™ DisksTips SCX

SCX membrane, 96/pk Tips-SCX.T1.200.96

Tips-SCX.T1. 1000.96

AttractSPE™ DisksTips C18-SCX

Stacking C18 & SCX membranes, 96/pk

Tips-C18-SCX.T1.200.96

Tips-C18-SCX.T1. 1000.96

AttractSPE™ DisksTips C18-SCX-C18

Stacking C18 & SCX &C18 membranes, 96/pk

Tips-C18-SCX-C18.T1.200.96

Tips-C18-SCX-C18.T1. 1000.96

AttractSPE™ DisksTips SDB-SAX

Stacking PS-DVB & SAX membranes, 96/pk

Tips-DVB-SAX.T1.200.96

Tips-DVB-SAX.T1. 1000.96

AttractSPE™ DisksTips Silica

Silica membranes, 96/pk Tips-Si.T1.200.96 Tips-Si.T1. 1000.96

Advantages•Load your sample on AttractSPE™DisksTips for desalting or fractionate peptides/proteins – bioanalysis of small molecules

•Several sorbents based Stage-tips andstacking

•Available as 10, 20, 100, 200µL, 1mL

Page 24: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks 96 plate for microelution

24

Designation Description Reference – 1/pk Reference – 1/pk

AttractSPE™ Disks 96 plate C18 C18 membrane, 1/pk µ96W-C18.T1.1 µ96W-C18.T2.1

AttractSPE™ Disks 96 plate C18 EC

End-capped C18 membrane, 1/pk µ96W-C18EC.T1.1 µ96W-C18EC.T2.1

AttractSPE™ Disks 96 plate C18 NEC

Not end-capped C18 membrane, 1/pk

µ96W-C18NEC.T1.1

µ96W-C18NEC.T2.1

AttractSPE™ Disks 96 plate C8 C8 membrane, 1/pk µ96W-C8.T1.1 µ96W-C8.T2.1

AttractSPE™ Disks 96 plate SDB

PS-DVB membrane, 1/pk µ96W-DVB.T1.1 µ96W-DVB.T2.1

AttractSPE™ Disks 96 plate SDB – RPS

Modified DVB membrane, 1/pk µ96W-RPS.T1.1 µ96W-RPS.T2.1

AttractSPE™ Disks 96 plate SAX SAX membrane, 1/pk µ96W-SAX.T1.1 µ96W-SAX.T2.1

AttractSPE™ Disks 96 plate SCX SCX membrane, 1/pk µ96W-SCX.T1.1 µ96W-SCX.T2.1

AttractSPE™ Disks 96 plate WCX WCX membrane, 1/pk µ96W-WCX.T1.1 µ96W-SCX.T2.1

AttractSPE™ Disks 96 plate C18-SCX

Stacking C18 & SCX membranes, 1/pk

µ96W-C18-SCX.T1.1

µ96W-C18-SCX.T2.1

AttractSPE™ Disks 96 plate C18-SCX-C18

Stacking C18 & SCX &C18 membranes,

1/pk

µ96W-C18-SCX-C18.T1.1

µ96W-C18-SCX-C18.T2.1

AttractSPE™ Disks 96 plate Silica

Silica membranes, 1/pk µ96W-Si.T1.1 µ96W-Si.T2.1

AttractSPE™ Disk 96 Plate for microelution is a 96 plate with wells similar to stagetips fora high throughput clean-up requiring microelution volumes.

Page 25: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks 96 plate – 1mL

25

Designation Description Reference – 1/pk

AttractSPE™ Disks 96 plate C18 C18 membrane, 1/pk 96W-C18.T1.1

AttractSPE™ Disks 96 plate C18 EC End-capped C18 membrane, 1/pk 96W-C18EC.T1.1

AttractSPE™ Disks 96 plate C18 NEC

Not end-capped C18 membrane, 1/pk 96W-C18NEC.T1.1

AttractSPE™ Disks 96 plate C8 C8 membrane, 1/pk 96W-C8.T1.1

AttractSPE™ Disks 96 plate SDB PS-DVB membrane, 1/pk 96W-DVB.T1.1

AttractSPE™ Disks 96 plate SDB –RPS

Modified DVB membrane, 1/pk 96W-RPS.T1.1

AttractSPE™ Disks 96 plate SAX SAX membrane, 1/pk 96W-SAX.T1.1

AttractSPE™ Disks 96 plate SCX SCX membrane, 1/pk 96W-SCX.T1.1

AttractSPE™ Disks 96 plate C18-SCX

Stacking C18 & SCX membranes, 1/pk 96W-C18-SCX.T1.1

AttractSPE™ Disks 96 plate C18-SCX-C18

Stacking C18 & SCX &C18 membranes, 1/pk

96W-C18-SCX-C18.T1.1

AttractSPE™ Disks 96 plate SDB-SAX

Stacking PS-DVB & SAX membranes, 1/pk 96W-DVB-SAX.T1.1

AttractSPE™ Disks 96 plate Silica Silica membranes, 1/pk 96W-Si.T1.1

AttractSPE™ Disk 96 Plate is a plate with 96 SPE wells of 1mL containingimmobilized SPE disks that enables a high throughput clean-up with thesimultaneous preparation of 96 samples. Thanks to this small sorbentamount and a high efficiency, almost 100% of the original sample isrecovered.

Advantages

•All sorbents available on catalog or ondemand•Several sorbent weights available.•Easy handling with automates or liquidhandling robots - spinnable•AttractSPE™ Manifold for 96 wellPlateformat or AttractSPE™ Positive pressureManifold for 96 well Plate

Page 26: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 26

AttractSPE™ Disks Spin Column is an SPE column createdby immobilizing a monolithic disk inside amicrocentrifuge SPE tube. Thanks to its self stand, themonolith disk requires no frits for immobilizing thecolumn bed (unlike traditional SPE products), whichallows essentially 100% recovery of the original samplevolume after a couple of brief centrifugations.

AttractSPE™ Disks Spin Column for microelution

Conditioning ElutionWashingAdsorption

Purifiedsample

Spin tube

AttractSPE™ Disks

Page 27: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks Spin Column

27

Designation Description Reference micro spin – 96/pk

Reference mini spin – 96/pk

AttractSPE™ Disks SpinC18 C18 membrane, 96/pk µSpin-C18.T1.96 Spin-C18.T1.96

AttractSPE™ Disks SpinC18 EC

End-capped C18 membrane, 96/pk

µSpin-C18EC.T1.96 Spin-C18EC.T1.96

AttractSPE™ Disks SpinC18 NEC

Not end-capped C18 membrane, 96/pk

µSpin-C18NEC.T1.96

Spin-C18NEC.T1.96

AttractSPE™ Disks SpinC8 C8 membrane, 96/pk µSpin-C8.T1.96 Spin-C8.T1.96

AttractSPE™ Disks SpinSDB

PS-DVB membrane, 96/pk µSpin-DVB-T1-96 Spin-DVB.T1.96

AttractSPE™ Disks SpinSDB – RPS

Modified DVB membrane, 96/pk µSpin-RPS-T1-96 Spin-RPS.T1.96

AttractSPE™ Disks SpinSAX SAX membrane, 96/pk µSpin-SAX

-T1-96Spin-SAX

.T1.96

AttractSPE™ Disks SpinSCX SCX membrane, 96/pk µSpin-SCX-T1-96 Spin-SCX.T1.96

AttractSPE™ Disks SpinC18-SCX

Stacking C18 & SCX membranes, 96/pk

µSpin-C18-SCX-T1-96

Spin-C18-SCX.T1.96

AttractSPE™ Disks SpinC18-SCX-C18

Stacking C18 & SCX &C18 membranes,

96/pk

µSpin-C18-SCX-C18-T1-96

Spin-C18-SCX-C18.T1.96

AttractSPE™ Disks SpinSDB-SAX

Stacking PS-DVB & SAX membranes, 96/pk

µSpin-DVB-SAX-T1-96

Spin-DVB-SAX.T1.96

AttractSPE™ Disks SpinSilica

Silica membranes, 96/pk µSpin-Si-T1-96 Spin-Si.T1.96

Reservoirs for AttractSPE™ Disks Spin 25mL- 96/pk Spin-Res-96 Spin-Res-96

Advantages

•4 spin size formats: micro and minispin,15mL and 50mL spin tubes

•Fast and easy extraction process bycentrifugation

•High throughput purification•Easy scale up of the process

Mini spinMicro spin

Page 28: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks Spin Column

28

Designation DescriptionReference 15mL

spin tube – 50/pkLoading <4mL

Reference 50mL spin tube – 50/pk

Loading <22mL

AttractSPE™ Disks SpinC18 C18 membrane, 50/pk Spin15-C18.T1.50 Spin50-C18.T1.50

AttractSPE™ Disks SpinC18 EC

End-capped C18 membrane, 50/pk

Spin15-C18EC.T1.50

Spin50-C18EC.T1.50

AttractSPE™ Disks SpinC18 NEC

Not end-capped C18 membrane, 50/pk

Spin15-C18NEC.T1.50

Spin50-C18NEC.T1.50

AttractSPE™ Disks SpinC8 C8 membrane, 50/pk Spin15-C8.T1.50 Spin50-C8.T1.50

AttractSPE™ Disks SpinSDB

PS-DVB membrane, 50/pk Spin15-DVB-T1-50 Spin50-DVB.T1.50

AttractSPE™ Disks SpinSDB – RPS

Modified DVB membrane, 50/pk Spin15-RPS-T1-50 Spin50-RPS.T1.50

AttractSPE™ Disks SpinSAX SAX membrane, 50/pk Spin15-SAX

-T1-50Spin50-SAX

.T1.50

AttractSPE™ Disks SpinSCX SCX membrane, 50/pk Spin15-SCX-T1-50 Spin50-SCX.T1.50

AttractSPE™ Disks SpinC18-SCX

Stacking C18 & SCX membranes, 50/pk

Spin15-C18-SCX-T1-50

Spin50-C18-SCX.T1.50

AttractSPE™ Disks SpinC18-SCX-C18

Stacking C18 & SCX &C18 membranes, 50/pk

Spin15-C18-SCX-C18-T1-50

Spin50-C18-SCX-C18.T1.50

AttractSPE™ Disks SpinSDB-SAX

Stacking PS-DVB & SAX membranes, 50/pk

Spin15-DVB-SAX-T1-50

Spin50-DVB-SAX.T1.50

AttractSPE™ Disks SpinSilica Silica membranes, 50/pk Spin15-Si-T1-50 Spin50-Si.T1.50

AttractSPE™ Disk Spin columns of 15mLand 50mL are the perfect tools to scale upfractionation and desalting of peptidesthanks to a high area of SPE disks.

Page 29: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks Cartridges

29

DesignationReference – 1mL

– 50/pkReference – 3mL –

50/pkReference – 6mL –

50/pk

AttractSPE™ DisksCartridge C18 CAR1-C18.T1.50 CAR3-C18.T1.50 CAR6-C18.T1.50

AttractSPE™ DisksCartridge C18 EC

CAR1-C18EC.T1.50 CAR3-C18EC.T1.50 CAR6-C18EC.T1.50

AttractSPE™ DisksCartridge C18 NEC

CAR1-C18NEC.T1.50

CAR3-C18NEC.T1.50

CAR6-C18NEC.T1.50

AttractSPE™ DisksCartridge C8 CAR1-C8.T1.50 CAR3-C8.T1.50 CAR6-C8.T1.50

AttractSPE™ DisksCartridge SDB CAR1-DVB-T1-50 CAR3-DVB-T1-50 CAR6-DVB.T1.50

AttractSPE™ DisksCartridge SDB – RPS CAR1-RPS-T1-50 CAR3-RPS-T1-50 CAR6-RPS.T1.50

AttractSPE™ DisksCartridge SAX

CAR1-SAX-T1-50

CAR3-SAX-T1-50

CAR6-SAX.T1.50

AttractSPE™ DisksCartridge SCX CAR1-SCX-T1-50 CAR3-SCX-T1-50 CAR6-SCX.T1.50

AttractSPE™ DisksCartridge C18-SCX

CAR1-C18-SCX-T1-50

CAR3-C18-SCX-T1-50

CAR6-C18-SCX.T1.50

AttractSPE™ DisksCartridge C18-SCX-C18

CAR1-C18-SCX-C18-T1-50

CAR3-C18-SCX-C18-T1-50

CAR6-C18-SCX-C18.T1.50

AttractSPE™ DisksCartridges SDB-SAX

CAR1-DVB-SAX-T1-50

CAR3-DVB-SAX-T1-50

CAR6-DVB-SAX.T1.50

AttractSPE™ Disks 96 Cartridges Silica CAR1-Si-T1-50 CAR3-Si-T1-50 CAR6-Si.T1.50

Advantages

•3 and 6mL format•Larger loading volume with a minimalelution volume

•High extraction capacity•A broad range of sorbents or sorbentcombination

Page 30: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks BioMol to do your own tools

30

Designation DescriptionReference – 25mm

– 40/pkReference – 47mm

– 20/pk

AttractSPE™ DisksBio C18

C18 sorbent SPE-Disks-Bio-C18-100.25.40

SPE-Disks-Bio-C18-100.47.20

AttractSPE™DisksBio C8

C8 sorbent SPE-Disks-Bio-C8-100. 25.40

SPE-Disks-Bio-C8-100.47.20

AttractSPE™DisksBio C4

C4 sorbent SPE-Disks-Bio-C4-300. 25.40

SPE-Disks-Bio-C4-300.47.20

AttractSPE™DisksBio HLB

HLB sorbent SPE-Disks-Bio-HLB-25.40

SPE-Disks-Bio-HLB-47.20

AttractSPE™DisksBio SDB

PS-DVB sorbent SPE-Disks-Bio-DVB-25.40

SPE-Disks-Bio-DVB-47.20

AttractSPE™DisksBio SDB-RPS

Modified SDB-RPS sorbent

SPE-Disks-Bio-RPS-25.40

SPE-Disks-Bio-RPS-47.20

AttractSPE™DisksBio SAX

SAX sorbent SPE-Disks-Bio-SAX-25.40

SPE-Disks-Bio-SAX-47.20

AttractSPE™DisksBio SCX

SCX sorbent SPE-Disks-Bio-SCX-25.40

SPE-Disks-Bio-SCX-47.20

Advantages

•Automated process to desalt orfractionate proteins or peptides

•Liquid handling robotics•Can be used for StageTips, 96 Wellplates

•25mm or 47mm

AttractSPE Disks for molecular biology purpose

Page 31: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Solid Phase Extraction Solutions

31

200mL – 1mL

• AFFINIMIP® SPE

• AttractSPE™

• SilactSPE™

• Qcleanup™ Quechers

• AttractFiltra™ Filtration

• AttractSPE™ SLE

For simple to very

complex matrices

Page 32: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINISEP offers a complete range of sorbents for solidphase extraction from very specific to crude clean-upphases, from silica to polymers, from conventional tomore sophisticated sorbents for various applications.

Solid Phase Extraction from Every angle!

32

Page 33: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 33

AFFINISEP offers a complete range of chemical phases for solid phase extractionfrom very specific to crude clean-up phases, from silica to polymers, fromconventional to more sophisticated one for various applications.

AFFINIMIP®SPEAFFINIMIP®SPE is a selective solid phase extraction based on Molecularly ImprintedPolymers (MIP) that combines the advantages of immune-affinity columnsregarding the selectivity and those of polymeric SPE sorbents in terms of costs androbustness. Developed for complex extraction, an instruction sheet gives allrequired information to successfully carry out the analysis, including the protocol.No method development is required. The protocol is easy, simple and fast. Thechromatographic analysis is fast thanks to the affinity between the analyte andAFFINIMIP®SPE. Methods are developed using the most common matrix containingthe analyte. These matrices can be as diverse as aqueous matrices (food, feed andbiological matrices), fully organic matrices (oil), powdery (milk) or cereals grains. Ifyour sample preparation is complex or gives unreliable results, the development ofan AFFINIMIP® SPE can be a solution.

AttractSPE™ Polymeric sorbentsAttractSPE™ are the last generation of polymeric SPE sorbent. They are crosslinkedpolymer particles bearing various chemical functionalities.These chemical phases provide all the advantages of polymeric material, includingrobustness (to solvent, pH and T), simplified method development, wideapplicability and not affected by drying out. The combination of the water-wettableoptimised surface chemistry, high surface area and pH stability ensures highreproducible recoveries for a wide range of analytes. Thanks to their capacity, forthe same application, less sorbent and less solvent are required than for silica-basedsorbent and so, their added value is particularly obvious for trace analysis and forsmall volume sample.

SilactSPE™ inorganic-based chemical phasesThe first chemical phases historically used for SPE applications, Silica, Alumine-based sorbents offer a broad range of chemically modified sorbents. This chemistrygoes from very polar sorbent to hydrophobic sorbent (end-capped saturatedhydrocarbon) passing through intermediate polarity (for instance, amino). Thesesorbents are sensitive to extreme pH. They are adequate for non-polar analytes insimple matrices.

SOLID PHASE EXTRACTION

Page 34: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

The choice of the chemical phase is crucial for a successful sample pre-treatment. When an AFFINIMIP® SPE exists for the analyte, the choice is verysimple and the problem is solved. The protocol is simple and ready to use.AFFINIMIP® SPE have been developped for various trace analyses in complexmatrices and for problematic analysis with common SPE sorbents.When no AFFINIMIP® SPE product is available, you can check the applicationnotebook available on our website to use the appropriate samplepretreatment.In other cases, the sorbent chemistry must be chosen very carefully and eachstep of the protocol must be optimized. This choice is based on analyte andmatrix nature, on the loading condition and on the planned retentionmechanism with the sorbent.The following scheme gives a brief guideline to select the family of sorbents.For specific applications such as trace analysis or complex matrices,conventional SPE sorbents may give very complex analysis or unsatisfayingresults. The development of an AFFINIMIP® SPE sorbent for this application isa solution. We provide as well services for method development.

Analyte of interest :Existing AFFINIMIP® SPE ?

Selection of a sorbent

YESProblem solved

Ready to use Protocol

NO

AqueousNature of thematrix

Water miscible organic solvent

Not water miscible organic solvent

Nature of the analyte Ionic Neutral Polar to

Moderately polarModerately to

Non Polar

Ion-ExchangeAttractSPE™ AttractSPE™ DVB

Normal phase SilactSPE™Attract SPE™ HLB

Sorbent:

QUICK LOOK-UP GUIDE

Check the application notebook

34

Page 35: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE and

dedicated applicationsSelective Solid Phase ExtractionMolecularly Imprinted Polymers for the Selective

Extraction of Trace Analytes from Complex Matrices

35

Page 36: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

New Extraction Phase Based on Molecularly Imprinted Polymers (MIPs)MIPs are polymers with shape «memory» and functional groups affine to atemplate molecule. Using an imprinting process, AFFINISEP designs these materialsin order to recognize selectively a target molecule, even in the presence ofcompounds with structure and functionality similar to the template.

AFFINIMIP® SPE - CONCEPTS

Advantages of SPE based molecularly imprinted polymers

Molecular Recognition materials

AFFINISEP designs these materialsfor an broad variety of molecules, such as (mycotoxines, antibiotics, …) , pharmaceuticals, etc…

High affinity and selectivity

Ensure analysisReproducibilityand reliability via robustand rapid methodology

AFFINIMIPSynthetic materials

Analytical and preparativeapplications in research andproduction

Stable to•pH variation•Temperature variation•Organic solvents

Selective Solid Phase Extraction

Molecularly Imprinted Polymers for theSelective Extraction of Trace Analytes fromComplex Matrices

36

Page 37: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE is a selective solid phase extraction based on MolecularlyImprinted Polymers (MIP). It combines the advantages of immune-affinitycolumns regarding the selectivity and of a classic Solid Phase Extraction(SPE) in terms of robustness and costs.

AFFINIMIP® SPE Selective Extraction CartridgesPerfect clean-up system for trace analysisThanks to the selectivity of AFFINIMIP®SPE, stringent washing steps can beapplied in order to remove all interferences and thus minimize matrixeffects. It also reduces ion-suppression effects.Minimal or no method development requiredA protocol based on three steps (loading, washing and elution) is suppliedwith AFFINIMIP®SPE kits for tested matrices. No extra-equipment than theusual required for SPE experiments is necessary.

AFFINIMIP® SPE FOR ANALYTICAL PURPOSE

AFFINIMIP® SPE protocols are as well defined by 3 steps of loading,washing and elution. All steps have been already developed in detail byAFFINISEP and an instruction sheet is supplied with the product.

37

Loading sample Washing Elution

SPE Sorbent

Conditioning

Concentratedand cleaned

sample

Page 38: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE FOR ANALYTICAL PURPOSE

The advantages of AFFINIMIP® SPE are essential in trace analysis from acomplex matrice in food safety, environment, cosmetics, clinical chemistry.pharmaceutical analysis and others.The SPE protocol is supplied in an instruction sheet for various complexmatrices.For other matrices, please contact our technical support to help you withyour application.

38

Example of an instruction sheet supplied with AFFINIMIP® SPE

Page 39: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Mycotoxins are toxic secondary metabolites produced by different fungi presentin agricultural commodities. They are regulated in food and feed due tonephrotoxic, neurotoxic, carcinogenic, estrogenic, and immunosuppressiveeffects.

AFFINISEP has developed two sets of products for mycotoxins analyses:

Multimycotoxins extraction: Designed for the simultaneous extraction ofseveral mycotoxins which are present in the same matrix prior to LC-MS/MSanalyses. These mycotoxins are all present in the same matrix to be analyzed.Their extraction is done all at once by SPE.

AFFINIMIP® SPE Multimyco LCMSMS for the analyses ofFumonisinsAflatoxinsOchratoxin AT-2 and HT-2ZearalenoneDeoxynivalenol

AFFINIMIP® SPE FumoZON for the analyses ofFumonisinsZearalenone

Single mycotoxin extraction: Designed for the analysis of one specific family ofmycotoxin:

AFFINIMIP® SPE PatulinAFFINIMIP® SPE Ochratoxin AAFFINIMIP® SPE ZearalenoneAFFINIMIP® SPE FumonisinsAFFINIMIP® SPE DeoxynivalenolAFFINIMIP® SPE Aflatoxine

39

MYCOTOXINS ANALYSES

Page 40: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Multimyco LCMSMS

40

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEMultimyco LCMSMS 6mL FS118-02B-200 FS118-03B-200

Analytes

•Fumonisins B1/B2•Aflatoxins B1/B2/G1/G2•Ochratoxin A •T-2 and HT-2•Zearalenone•Deoxynivalenol

Matrices

•Wheat, Maize, Cereals, sunflowerseeds, …

Advantages

•SIMULTANEOUSLY clean-up andconcentrate the main regulatedmycotoxins

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Regulation

In Europe, these mycotoxins areall regulated (see set values foreach individual mycotoxin)Aflatoxins - 1881/2006/EC :foodstuffs : 0,1µg/kg Afla B1 forprocessed cereals for baby food4,0 µg/kg for total aflas inprocessed cereals

Page 41: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE FumoZON

41

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE FumoZON 3mL FS109-02 FS109-03

Analytes

•Fumonisins B1+B2•Zearalenone

Matrices

•Wheat, Maize, Cereal-based babyfood,

Advantages

•SIMULTANEOUS analysis by LC-MSdetection

•Very simple protocol

Application notes et publications are available on our website.

Regulation

Europe - 1126/2007/EC:20µg/kg and 200µg/kg on maize-based babyfood for respectivelyZearalenone and FumonisinsCodex Alimentarius - (193-1995): 2000µg FumonisinsB1+B2/kg for whole commodity

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 42: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Patulin

42

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE Patulin

3mL FS102-02 FS102-036mL FS102-02B FS102-03B3mL

50mL Pectinase FS102-02K FS102-03K

6mL& 50mL Pectinase –

1unit

FS102-02KB-200mg

FS102-03KB-200mg

Pectinase enzymaticSolution 50mL – 1 unit REA-001-50mL

Patulin standard solution 1mL vial

100µg/mLREA-PAT-1mL

Analytes

•Patulin

Matrices

•Apple juice (clear & cloudy), Appleand Multifruit puree, Baby food,Cider, Alcohol, Pommeau, Manzella,Dried apple, Blueberry, TomatoKetchup

Advantages

•Applicable to several apple derivedmatrices

•Unique extraction method availableon the market

•UV or LC-MS detection

Regulation

Regulations for apple puree:Europe - 1881/2006/EC :25µg/kg; 10µg/kg for infantsand young childrenUSA (FDA CPG Sec.510.150) :50µg/kgRegulations for apple juice :Europe - 1881/2006/EC :50µg/kg; 10µg/kg for infantsand young childrenCodex alimentarius: (193-1995): 50µg/kg apple juice

Application notes et publications are available on our website.

Page 43: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Ochratoxin A

43

Analytes

•Ochratoxin A

Matrices

•Wheat, Maize, red and white Wine,Several spices (Paprika, Pepper,ginger…), Coco, Human urine…

Advantages

•Storage at RT like all AFFINIMIP®SPE•Simple protocols•Fluorescence or LC-MS detection

Regulation

Europe - 1881/2006/EC:foodstuffs : 5μg/kg in raw cerealgrains, 30μg/kg in spices, 2µg/kgin wine….Codex Alimentarius - (193-1995): 5µg/Kg for wheat, barley,rye…

Application notes et publications are available on our website.

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEOchratoxin A

3mL FS101-02 FS101-03

6mL FS101-02B FS101-03B

10mL LRC FS101-02LRC FS101-03LRC

3mL for automateGERSTEL - FS101-03-GER

3mL for automateGILSON - FS101-03-GIL

6mL for automateGERSTEL - FS101-03B-GER

6mL for automateGILSON - FS101-03B-GIL

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 44: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Deoxynivalenol

44

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEDeoxynivalenol

6mL -100mg in food and babyfood FS117-02B FS117-03B

6mL – 200mg in feed FS117-02B-200mg FS117-03B-200mg

Analytes

•Deoxynivalenol (a.k.a Vomitoxin)•3-AcetylDON•15-AcetylDON

Matrices

•Oat, wheat, corn, baby food, meat,animal feed…

Advantages•UV and LC-MS detection

Regulation

Europe - 1126/2007/EC :1750µg/kg for unprocessedmaize, 200µg/kg for babyfoodcereals.US FDA : 1 ppm in finishedwheat products for humanconsumptionCodex Alimentarius - (193-1995): 1000µg/kg for flourmaize, wheat, barley, 200µg/kgfor babyfood cereals.

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 45: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Zearalenone

45

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEZearalenone

3mL FS100-02 FS100-03

10mL LRC FS100-02LRC FS100-03LRC

3mL for automateGERSTEL - FS100-03-GER

3mL for ASPEC automateGILSON - FS100-03-GIL

Analytes

•Zearalenone, Zearalanone, α-zearalenol, α-zearalanol, β-zearalenol, β-zearalanol

Matrices

•Wheat, Maize, Cereal-based babyfood, Edible corn oil and Rice

Advantages

•Fluorescence or LC-MS detection

Regulation

Europe - 1881/2006/EC :foodstuffs : 100µg/kg incereals and 20µg/kg in maize-based babyfood.

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 46: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Glyphosate

46

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEGlyphosate

3mL FS113-02.IP FS113-03.IP

6mL FS113-02B FS113-03B

12mL FS113-02C FS113-03C

Analytes

•Glyphosate•AMPA•Glufosinate

Matrices

•Waters: Geothermal, mineral, riveror underground

•Foodstuffs: cereals, honey, tea,juices, cannabis

Advantages

•NO DERIVATIZATION required toextract the analytes

•Fluorescence (with derivatization),LC-MS or Capillary Electrophorisis -UV detection

•Fast and simple protocol

Regulation

In Europe, Glyphosate is adebatable active substance, ithas been thoroughly assessed byMember States andthe European Food SafetyAuthority (EFSA). In December2017: the Commission hasadopted an act to renew theapproval of glyphosate for 5yearsCodex alimentarius : 50µg/kg inmeat or milk

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 47: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Picolinic Herbicides

47

Designation Description 25c/box 50 c/box

AFFINIMIP®SPEPicolinic

Herbicides

3mL FS115-02 FS115-03

6mL FS115-02B FS115-03B

10mL LRC FS115-02LRC FS115-03LRC

12mL FS115-02C -

Analytes

•Picloram•Aminopyralid•Clopyralid

Matrices

•Water, Compost, Cereal, Soil…

Advantages

•Fast, short and easy protocol

Regulation

Europe - 322/2012/EC: 0.1 to 5mg Clopyralid/kg in cereals2017/171/EC: 10µgAminopyralid/kg in nuts,vegetable, oilseeds…

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 48: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE PAHs

48

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE PAHs

3mL FS119-02 FS119-03

6mL FS119-02B FS119-03B

10mL LRC FS119-02LRC FS119-03LRC

12mL FS119-02C -

96 well plate – 1 unit FS119-1.96W

Analytes

•Benzo[a]anthracen B[a]A;Benzo[a]pyren B[a]P; Benzo[a]fluoranthen B[a]F; Chrysen (CHR),etc.

Matrices

•Edible oils (colza, oliva…), fattyfood

Advantages

•LC-MS, HPLC/UV, Fluorescence•Fast and simple protocol

Regulation

Europe (EC 835/2011) 2 ng/g benzo[a]pyreneindividually, and 10 ng/g benzo[a]pyrene, benzo[b]fluoranthene, chrysene and benzo[a]anthracenecombined for edible oils

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 49: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Tetracyclines

49

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE

Tetracyclines

1mL FS112-02A FS112-03A

3mL FS112-02 FS112-03LRC 10mL FS112-02LRC FS112-03LRC

96 well plate – 1 unit FS112-1.96W

Multipurpose sampler automate

(GERSTEL)-1mL- FS112-03A-GER

ASPEC automate (GILSON)-1mL - FS112-03A-GIL

ASPEC automate (GILSON)-3mL - FS112-03-GIL

Analytes

•Tetracycline•Chlortetracycline•Oxytetracycline, their epimers• Doxycycline.

Matrices

•Meat, Tissues, Animal source foods,milk

Advantages

•UV detection

Regulation

Europe : 37/2010/EU100µg/kg in muscle or milkCodex alimentarius : 100µg/kg of milk; 200µg/kg ofmuscle

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 50: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Chloramphenicol

50

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEChloramphenicol

1mL FS110-02A FS110-03A

3mL FS110-02 FS110-03

LRC 10mL FS110-02LRC FS110-03LRC

96 well plate – 1 unit FS110-1.96W

Analytes

•Chloramphenicol

Matrices

•Honey, Milk, Shrimp, Bovine Urine

Advantages

•Very low limit of detection•LC-MS

Application notes et publications are available on our website.

Regulation

Europe - 2003/181/EC:minimum requiredperformance 0.3µg/kg inresidue of animal originUS FDA : prohibited

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 51: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Aminoglycosides

51

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEAminoglycosides

3 mL FS124-02 FS124-03

6mL FS124-02B FS124-02B

Regulation

Europe – 37/2010/EC: 50µgtotal Gentamycins/kg 100µgKanamycin A/kg, 300µgSpectinomycin/kg, 500µgDihydrostreptomycin in muscleCodex Alimentarius - 100µgtotal Gentamycins/kg, 500µgSpectinomycin/kg, 600µgDihydrostreptomycin +Streptomycin in muscle

Application notes et publications are available on our website.

Analytes

Analytes

•Spectinomycin, Hygromycin B, Streptomycin, Dihydrostreptomycin, Amikacin, Kanamycin A, Apramycin, Paromomycin, Tobramycin, Sisomicin, Gentamicin C1a, Gentamicin C2, Neomycin B

Matrices

•Tissus muscles, milk, fish, egg

Advantages

•SIMULTANEOUS analysis by LC-MSdetection

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 52: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Estrogens

52

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEEstrogens

1mL FS104-02A FS104-03A

3mL FS104-02 FS104-036mL FS104-02B FS104-03B

10mL LRC FS104-02LRC FS104-03LRC12mL FS104-02C FS104-03C

96 well plate – 1 unit FS104-1.96WReversible cart. –

0.7mL FS104-02Rev1 FS104-03Rev1

Reversible cart. – 2 mL FS104-02Rev2 FS104-03Rev2

Analytes

•Broad family of natural and synthetic estrogens

Matrices

•Waters, river water and sediment,Plasma, treated sewage, animalbody fluid

Advantages

•LC-MS, GC/MS

Regulation

Europe : COM(2011)876proposed Ethinylestradiol and 17α-Ethinylestradiol as prioritysubstances in waterUSA: 17 α-Etinylestradiol, Estriol,Estrone and Ethinylestradiol inContaminant candidate list CCL3

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 53: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Bisphenols

53

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE Bisphenols

3mL (PP) FS106-02 FS106-03

6mL (PP) FS106-02B FS106-03B

6mL (Glass) FS106-02G FS106-03G

10mL LRC (PP) FS106-02LRC FS106-03LRC

12mL (PP) FS106-02C FS106-03C96 well plate – 1 unit FS106-1.96WMultipurpose sampler automate (GERSTEL) -

3mL- FS104-03-GER

ASPEC automate (GILSON) - 3mL - FS104-03-GIL

Analytes

•Bisphenols such as Bisphenol A and closely 18 related structures

Matrices

•Water, milk (infant formula),powdered infant formula, cannedfood, vegetable puree for infant,Beer, urine, …

Advantages

•SIMULTANEOUS analyis of bisphenolsanalogs

•Broad range of solid and liquid foodstested

•LC-MS, GC/MS, fluorescence

Regulation

Europe 2011/8/EU : forbiden ininfant feeding bottleSpecific migration limit of0.6mg/kg in food from packagingForbiden in food materials inFrance

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 54: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Zeranol Residues

54

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEZeranol Residues

3mL FS105-02 FS105-03

LRC 10mL FS105-02LRC FS105-03LRC

Analytes

•Zeranol•Zearalenone•β-Zearalanol (Taleranol)• α and β-Zearalenol•Zearalanone•Resorcylic acid lactones

Matrices

•Meat, Urine, Tissues, Plasma

Advantages

•LC-MS, HPLC-Fluorescence

Regulation

Its use is banned in severalcountries (e.g. Europeandirective 96/22/EC and inChina).Codex alimentarius: 2µg/kg inmuscle

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 55: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Phenolics

55

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE Phenolics

3mL FS103-02 FS103-03

6mL FS103-02B FS103-03B

10mL LRC FS103-02LRC FS103-03LRC

12mL FS103-02C -

96 well plate – 1 unit FS103-1.96WReversible cart. –

0.7mL FS103-02Rev1 FS103-03Rev1

Reversible cart. – 2 mL FS103-02Rev2 FS103-03Rev2

Analytes•Parabens, carnosic acid, hydroxylatedPAHs

•Tocopherols•Nitrophenols•Chlorophenols•Catechins…

Matrices

•Food, cosmetic, wine, meat

Advantages

•Extraction of broad range of phenolicscompounds

•LC-MS, HPLC/UV

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 56: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE NNAL

56

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE NNAL

3mL DG103-02 DG103-03

10mL LRC DG103-02LRC DG103-03LRC96 well plate – 1

unit DG103-1.96W

Analytes

•Total and free NNAL (4-(methylnitrosamino) -1-(3-pyridyl) -1-butanol)

Matrices

•Urine

Advantages

•LC-MS & LC-MS/MS

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 57: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Amphetamines

57

Designation Description 25c/box 50 c/box

AFFINIMIP® SPEAmphetamines

3mL DG102-02 DG102-03

10mL LRC DG102-02LRC DG102-03LRC

96 well plate – 1 unit DG102-1.96W

Analytes

•Amphetamine•Methamphetamine derivatives

Matrices

•Urine, Serum

Advantages

• LC-MS

Regulation

Several US and Europeanstates have set up a cut-offvalue in urine or blood [e.g.France and Virginia(respectively 50ng/mL and100ng/mL of blood)].

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 58: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Catecholamines

58

Designation Description 25c/box 50 c/box

AFFINIMIP® SPECatecholamines

1mL DG100-02A DG100-03A

3mL DG100-02 DG100-03

10mL LRC DG100-02LRC DG100-03LRC

12mL DG100-02C -

96 well plate – 1 unit DG100-1.96W

Analytes

•Dopamine (DA)•Norepinephrine or Noradrenaline(NA)•Epinephrine or Adrenaline (A)

Matrices

•Plasma , Serum

Advantages

•LC-MS, HPLC/UV

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 59: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Metanephrines

59

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE

Metanephrines

1mL DG101-02A DG101-03A

3mL DG101-02 DG101-03

10mL LRC DG101-02LRC DG101-03LRC

96 well plate – 1 unit DG101-1.96W

Analytes

•Metanephrine•Normetanephrine•3-methoxytyramine

Matrices

•Plasma , Serum

Advantages

•LC-MS, HPLC/UV

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 60: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Tamoxifen

60

Designation Description 25c/box 50 c/box

AFFINIMIP® SPETamoxifen

3mL PH101-02 PH101-03

Analytes

•Tamoxifen• its metabolite: 4-HydroxyTamoxifen

Matrices

•Biofluids such as urine

Advantages

•LC-MS, HPLC/UV

Regulation

Since January 2000,Tamoxifen has beenincluded in the list ofprohibited substances bythe International OlympicCommittee.

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 61: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINIMIP® SPE Cannabis

61

Designation Description 25c/box 50 c/box

AFFINIMIP® SPE Cannabis

3mL PH123-02 PH123-03

6mL PH123-02B PH123-03B

10mL LRC PH123-02LRC PH123-03LRC

Analytes

•Tetrahydrocannabinol (THC) and its metabolites

•THC-OH•THC-COOH

Matrices

•Biofluids such as urine, saliva,blood

Advantages

•LC-MS

Regulation

This drug is forbidden in mostcountries in the world. However,some countries or US statesmake possible the use of thisproduct for medical use (e.g.Arizona, Florida, Louisiana…)and for even lesscountries/states for recreationaluse (e.g. Canada, California,Alaska, Massachusetts…).

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

Page 62: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 62

Designation Description 25c/box 50 c/box

AttractSPE™WAX-PFC

6mL-150mg WAX-PFC-25.S.6.150

WAX-PFC-50.S.6.150

Analytes

•Perfluorobutanoic acid (PFBA), Perfluoropentanoicacid (PFPeA), Perfluorohexanoic acid (PFHxA), Perfluoroheptanoic acid (PFHpA), Perfluorooctanoicacid (PFOA), Perfluorononanoic acid (PFNA), Perfluorodecanoic acid (PFDA), Perfluorotetradecanoic acid (PFTA), Perfluorobutanesulfonic acid (PFBS), Perfluorohexane sulfonic acid (PFHxS),

•Perfluorooctanesulfonic acid (PFOS)

Matrices

•Water

Advantages

•LC-MS/MC

Application notes et publications are available on our website.

Visit our website to know more about this product and its formats.Custom designed formats are available on demand.

AttractSPE™WAX-PFC FOR PERFLUORINATED COMPOUNDS

AttractSPE™WAX-PFC specially developed anddedicated to determine perfluorinatedcompounds.

HPLC colums for perfluorinated compounds (PFCs):Silact C18LC-P : Delay column for analysis of PFCs - 50x2.1mm - ref : C18LCP-50.2.1Silact C18LC-P - 150x2.1mm - ref : C18LCP-150.2.1

Page 63: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 63

AttractSPE™ NON-TARGET SCREENING& AttractSPE™CHELATING FOR METAL RETENTION

AttractSPE™CHELATING : A chelatingresin for the extraction of metal ionsAttractSPE™CHELATING is a polymerresin containing functional groupswhich particularly suits for theextraction of transition metal ions(Hg2+, Cu2+, Pb2+, Fe2+…) and Alkalineearth metals ions in water even inhighly concentrated salt solution. Ahigh selectivity towards metal ions isobtained by varying the pH.

Cartridges format,Sorbent amount #/box AttractSPE™

CHELATING

1mL , 30mg 100 MET-100.S.1.30

3mL, 60mg25 MET-25.S.3.60

50 MET50.S.3.60

6mL, 100mg25 MET-25.S.6.200

50 MET-50.S.6.200

6mL, 500mg25 MET-25.S.6.500

50 MET-50.S.6.500

96 wells Plate 1 MET-1.96W.30

Reversible 0.7mL, 30mg

25 MET-25.REV.1.N10

50 MET-50.REV.1.N10

Reversible 0.7mL, 100mg

25 MET-25.REV.1.F

50 MET-50.REV.1.F

Reversible2mL, 800mg

25 MET-25.REV.2.F

50 MET-50.REV.2.F

47mm or 90mm Disks

See page AttractSPE™Disks

for environmentalapplications

Cartridges format,Description #/box

AttractSPE™

Non-Target Screening

6mL , 300mgMixture of HLB-

WCX-WAX50 Screening1-

25.S.6.300

6mL , 300mgMixture of HLB-SCX-

SAX50 Screening2-

50.S.6.300

6mL , 300mgMixture of PSDVB-

WCX-WAX50 Screening3-

50.S.6.300

6mL , 300mgMixture of PSDVB-

SCX-SAX50 Screening4-

50.S.6.300

47mm or 90mm Disks

See page AttractSPE™Disks

for environmental

applications

AttractSPE™NON-TARGET SCREENING: a mixture of sorbents for Non-targetscreeningAttractSPE™NON-TARGET SCREENINGare combination of sorbents to detectthe presence of not regulated harmfulsubstances (including degradation by-products and metabolites)

Page 64: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 64

SilactSPE™ DAU DRUG OF ABUSE & SilactSPE™Organotins

SilactSPE™DAU particularly suits forbasic drugs of abuse determination(Amphetamines, opioides…) incomplex matrices such as humanurine.

Product InformationSilica type : 60 Å, 500 m2/g, 40-63 µm

Cartridgesformat,

Sorbent amount#/box SilactSPE™DAU

1mL, 50mg 100 DAU-100.S.1.50

1mL, 100mg 100 DAU-100.S.1.100

3mL, 200mg 50 DAU-50.S.3.200

3mL, 500mg 50 DAU-50.S.3.500

6mL, 500mg 50 DAU-50.S.6.500

6mL, 1g 50 DAU-50.S.6.1g

10mL LRC, 500mg 50 DAU-50.LRC.10.500

12mL, 2g 20 DAU-20.S.12.2g

SilactSPE™ Organotins : for organotinsanalysis following ISO 17353 and ISO23161 methodsSilactSPE Organotins is a column forthe analysis of these compounds inwater, soil, sediment, sludge and waste(soil-like material).This column can be used for theanalysis of:- Organotins cations (MonobutyltinBuSn3+; Dibutyltin Bu4Sn3+; TributyltinBu3Sn+; Monooctyltin OcSn3+; DioctyltinOc2Sn2+; Triphenyltin Ph3Sn+;Tricyclohexyltin Cy3Sn+)- Peralkylated organotin (TetrabutyltinBu4Sn)-Methyltin compounds(Monomethyltin MeSn3+; DimethyltinMe2Sn2+; Trimethyltin Me3Sn+)

Cartridges format,Sorbent amount #/box SilactSPE™

Organotins

25mL,3g Na2SO4 + 5g

Silica (3% water)

25 OSn-25.S.25.3g.5g

50 Osn-50.S.25.3g.5g

Page 65: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SPE FOR POLYCYCLIC AROMATIC HYDROCARBONS (PAHs)

65

Product Vol Sorbent 25 cartridges/box 50 cartridges/box

SilactSPE™

CN/SiOH

3mL 500mg/1g CNSiOH-25.S.3.500.1g CNSiOH-50.S.3.500.1g

6mL 500mg/1g CNSiOH-25.S.6.500.1g CNSiOH-50.S.6.500.1g

6mLglass 500mg/1g CNSiOH-25.G.6.500.1g CNSiOH-

50.G.6.500.1g

AFFINIMIP® SPE PAHs 3mL FS119-02 FS119-03

AttractSPE™

HLB 6mL 200mg HLB-25.S.6.200 HLB-50.S.6.200

AFFINIMIP®SPE PAHs

For the cleanupfo PAHs in FATTYfood and liquidsuch as oil

Molecularlyimprinted

polymer for PAHs.

SilactSPE™

CN/SiOH

For the cleanup of PAHs in SOIL

A two layer sorbents with

cyano modified silica and silica

sorbents

AttractSPE™

HLB

For the cleanup of PAHs in

WATER

HLB

Page 66: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 66

AttractSPE™SAX-HCO3

For the removal of anioniccontaminants and neutralization ofacidic samplesAttractSPE™SAX-HCO3 is a stronganion exchange sorbent withhydrogenocarbonate anion ascounterion. It is used for the removalof anionic contaminants from samplematrices and for the neutralization ofhighly acidic samples.

AttractSPE™PS-H

For the removal of alkaline earthand transition metals ions and toneutralize basic samples.AttractSPE™PS-H is a strong cationexchange sorbent in the H form. It isused for the removal of alkalineearth and transition metals ions andto neutralize basic samples.

SPE FOR INTERFERENCES REMOVAL

Cartridges format,Sorbent amount # /box AttractSPE™SAX-HCO3 AttractSPE™PS-H

1mL 100 SAX-HCO3-100.S.1.30

3mL, 60mg 25 SAX-HCO3-25.S.3.60 PSH-25.S.3.60

50 SAX-HCO3-50.S.3.60 PSH-50.S.3.60

6mL, 200mg25 SAX-HCO3-25.S.6.200 PSH-25.S.6.200

50 SAX-HCO3-50.S.6.200 PSH-50.S.6.200

6mL, 500mg 25 SAX-HCO3-25.S.6.500 PSH-25.S.6.500

50 SAX-HCO3-50.S.6.500 PSH-50.S.6.500

96 well Plate 1 SAX-HCO3-1.96W.30 PSH-1.96W.30

Reversible 0.7mL, 100mg

25 SAX-HCO3-25.REV.1.F PSH-25.REV.1.F

50 SAX-HCO3-50.REV.1.F PSH-50.REV.1.F

Reversible 2mL, 800mg

25 SAX-HCO3-25.REV.2.F PSH-25.REV.2.F

50 SAX-HCO3-50.REV.2.F PSH-50.REV.2.F

Product InformationPS-DVB polymer type: 60 Å, 600m2/g, 1meq/g, 40 µm

Product InformationPS-DVB type: 40 µm, 60 Å, 600 m2/g,0.3 meq/g

Page 67: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 67

Cartridgesformat, Sorbentamount

# /box AttractSPE™PS-Ag AttractSPE™PS-Ba SilactSPE™

HydroxyApatite

1mL, 30mg(50mg for HAp) 100 PSAg-100.S.1.30 PSBa-100.S.1.30 HAp-100.S.1.50

3mL, 60mg (200mg for HAp)

25 PSAg-25.S.3.60 PSBa-25.S.3.60

50 PSAg-50.S.3.60 PSBa-50.S.3.60 HAp-50.S.3.200

6mL, 200mg25 PSAg-25.S.6.200 PSBa-25.S.6.200 -

50 PSAg-50.S.6.200 PSBa-50.S.6.200 -

6mL, 500mg25 PSAg-25.S.6.500 PSBa-25.S.6.500

50 PSAg-50.S.6.500 PSBa-50.S.6.500 HAp-50.S.6.500

Reversible0.7mL, 400mg

25 PSAg-25.REV.1.F PSBa-25.REV.1.F

50 PSAg-50.REV.1.F PSBa-50.REV.1.F HAp-50.REV.1.F

AttractSPE™PS-Ag

Removal of halide ions (chloride, bromide, and

iodide) by precipitation

Strong cation exchange sorbentwith silver cation

as counterion.

AttractSPE™PS-Ba

Removal of sulfate ions by

precipitation

Strong cation exchange sorbent

with barium cation as counterion

SilactSPE™

HydroxyApatite

Removal of chloride, fluoride,

lanthanide & carbonate ions

Hydroxyapatite is a mineral compound

of structure Ca10(PO4)6(OH)2

SPE FOR INTERFERENCES REMOVAL

Page 68: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 68

AttractSPE™

POLYMERIC-BASED SPE

Page 69: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

A broad range of chemistry and format for your application

AttractSPETM Cartridges

Several particlessizes

(40µm or 60µm)

A support suitable for each

application

Higher capacitythan silica based

Stable on the whole pH range

Performances not affected by

drying

Extraction of a broad range of

apolar and polar compounds

69

Page 70: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Sample preparation

Conditioning and equilibration

loading of the solution

Washing with Formic acid 2%

2mL Methanol

2mL 5% NH4OH /Methanol

Sample preparation

Conditioning and equilibration

loading of the solution

Washing with NH4OH 5%

2mL Methanol

2mL 5% Formic acid/Methanol

Sample preparation

Conditioning and equilibration

loading of the solution

Washing with Methanol/ Water

2mL Methanol

Neutral compounds

Strong basesBasesStrong acids Acids

AttractSPE™

WAXStrong acids

pKa<1

AttractSPE™

SCXBases

pKa 2-10

AttractSPE™

WCXStrong Bases

pKa >10

AttractSPE™

SAXAcids

pKa 2-8

AttractSPE™

DVBNeutral

hydrophobic

AttractSPE™

HLBNeutral

AttractSPE™ are based on polymeric sorbents dedicated to the extraction ofcompounds from complex matrices. AttractSPE™ cartridges provide theadvantages of robustness, simplified method development, wide applicabilityand are not affected by drying out. The combination of the water-wettableoptimised surface chemistry, high surface area and pH stability ensures highreproducible recoveries for a wide range of analytes. Two particle sizes (40 and60µm) are available for a more flexible implementation of these products.The choice of the suitable AttractSPE™ columns can be done by using thefollowing method:• Check if a method already exists on our application notebook• Determination of the nature of the analyte (neutral, acid, base)• Determination of the pKa• Choice of the AttractSPE™ columns by using the following chart and

application of the general protocol described on the instruction sheet• Analysis of the recovery yields

POLYMERIC - BASED AttractSPE™ CARTRIDGES

70

Page 71: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™HLB is an unchargedHydrophilic and Lipophilic sorbentinteracting with both, hydrophilic andhydrophobic interactions. it particularlysuits for the extraction of a wide range ofanalytes (polar, apolar, neutral, acid,basic…)

Product InformationParticle diameter range : 40 and

60µmPore size: 70 ÅSurface area: 800 m2/gStorage : Ambient temperature

71

AttractSPE™ HLB

Format, amount #/box AttractSPE™ HLB -40µm AttractSPE™ HLB -80µm

1mL, 10mg, 100/pk 100 HLB-100.S.1.10

1mL, 30mg 100 HLB-100.S.1.30 HLB-100.S.1.30GP

3mL, 60mg 50 HLB-50.S.3.60 HLB-50.S.3.60GP

3mL, 100mg 50 HLB-50.S.3.100 HLB-50.S.3.100GP

6mL, 150mg 50 HLB-50.S.6.150 HLB-50.S.6.150GP

6mL, 200mg 50 HLB-50.S.6.200 HLB-50.S.6.200GP

6mL, 500mg 50 HLB-50.S.6.500 HLB-50.S.6.500GP

10mL LRC, 60mg 50 HLB-50.LRC.10.60

12mL, 500mg 25 HLB-25.S.12.500

12mL, 1g 25 HLB-25.S.12.1000

12mL, 2g 25 HLB-25.S.12.2000GP

20mL, 1g 25 HLB-25.S.20.1g

20mL, 2g 25 HLB-25.S.20.2g

96 well Plate, 10mg 1 HLB-1.96W.10

96 well Plate, 30mg 1 HLB-1.96W.30 HLB-1.96W.30GP

96 well Plate, 60mg 1 HLB-1.96W.60 HLB-1.96W.60GP

Reversible 0.7mL, 30mg 50 HLB-50.REV.1.N10

Reversible 0.7mL, 100mg 50 HLB-50.REV.1.F

Reversible 2mL, 225mg 50 HLB-50.REV.2.N10

Disks cartridges (sorbent isa SPE disk)

See page AttractSPE™Disks CartridgesHigh capacity for a minimal elution volume

Page 72: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Mixed-mode SPE for extraction of strongacid analytesAttractSPE™WAX is a weak anion exchangesorbent interacting with the analytes via amixed mode retention mechanism, ionexchange with weak basic functional groupsand reversed phase. It particularly suits forthe extraction of strong acids.

Product InformationParticle diameter range: 40 and

60µm Pore size: 60 ÅSurface area: 650 m2/gIonic capacity : 0.5 meq/gStorage: Ambient temperature

AttractSPE™ WAX

72

Format, amount #/box AttractSPE™WAX-40µm AttractSPE™ WAX -80µm

1mL, 10mg, 100/pk 100 WAX-100.S.1.10

1mL, 30mg 100 WAX-100.S.1.30 WAX-100.S.1.30GP

3mL, 60mg 50 WAX-50.S.3.60 WAX-50.S.3.60GP

3mL, 100mg 50 WAX-50.S.3.100 WAX-50.S.3.100GP

6mL, 150mg 50 WAX-50.S.6.150 WAX-50.S.6.150GP

6mL, 200mg 50 WAX-50.S.6.200 WAX-50.S.6.200GP

6mL, 500mg 50 WAX-50.S.6.500 WAX-50.S.6.500GP

10mL LRC, 60mg 50 WAX-50.LRC.10.60

12mL, 500mg 25 WAX-25.S.12.500

12mL, 1g 25 WAX-25.S.12.1000

12mL, 2g 25 WAX-25.S.12.2000GP

20mL, 1g 25 WAX-25.S.20.1g

20mL, 2g 25 WAX-25.S.20.2g

96 well Plate, 10mg 1 WAX-1.96W.10

96 well Plate, 30mg 1 WAX-1.96W.30 WAX-1.96W.30GP

96 well Plate, 60mg 1 WAX-1.96W.60 WAX-1.96W.60GP

Reversible 0.7mL, 30mg 50 WAX-50.REV.1.N10

Reversible 0.7mL, 100mg 50 WAX-50.REV.1.F

Reversible 2mL, 225mg 50 WAX-50.REV.2.N10

For perfluorinated compounds, please use AttractSPE™WAX - PFC

Page 73: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Mixed-mode SPE for extraction of strongbasic analytesAttractSPE™WCX is a weak cation exchangesorbent interacting with the analytes via amixed mode retention mechanism, ionexchange with weak acid functional groupsand reversed phase. It particularly suits forthe extraction of strong bases andquaternary amines.

Product InformationParticle diameter range : 40

and 60µm Pore size: 70 ÅSurface area: 850 m2/gIonic capacity: 0.77meq/gStorage : Ambient temperature

73

AttractSPE™ WCX

Format, amount #/box AttractSPE™WCX-40µm AttractSPE™ WCX -80µm

1mL, 10mg, 100/pk 100 WCX-100.S.1.10

1mL, 30mg 100 WCX-100.S.1.30 WCX-100.S.1.30GP

3mL, 60mg 50 WCX-50.S.3.60 WCX-50.S.3.60GP

3mL, 100mg 50 WCX-50.S.3.100 WCX-50.S.3.100GP

6mL, 150mg 50 WCX-50.S.6.150 WCX-50.S.6.150GP

6mL, 200mg 50 WCX-50.S.6.200 WCX-50.S.6.200GP

6mL, 500mg 50 WCX-50.S.6.500 WCX-50.S.6.500GP

10mL LRC, 60mg 50 WCX-50.LRC.10.60

12mL, 500mg 25 WCX-25.S.12.500

12mL, 1g 25 WCX-25.S.12.1000

12mL, 2g 25 WCX-25.S.12.2000GP

20mL, 1g 25 WCX-25.S.20.1g

20mL, 2g 25 WCX-25.S.20.2g

96 well Plate, 10mg 1 WCX-1.96W.10

96 well Plate, 30mg 1 WCX-1.96W.30 WCX-1.96W.30GP

96 well Plate, 60mg 1 WCX-1.96W.60 WCX-1.96W.60GP

Reversible 0.7mL, 30mg 50 WCX-50.REV.1.N10

Reversible 0.7mL, 100mg 50 WCX-50.REV.1.F

Reversible 2mL, 225mg 50 WCX-50.REV.2.N10

Page 74: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 74

Mixed-mode SPE for extraction of weakacid analytesAttractSPE™SAX is a strong anion exchangesorbent interacting with the analytes via amixed mode retention mechanism, ionexchange with strong basic functionalgroups and reversed phase. It particularlysuits for the extraction of weak acids.

Product InformationParticle diameter range : 40

and 60µmPore size: 60 ÅSurface area: 600 m2/gIonic capacity: 0.3 meq/gStorage : Ambient temperature

AttractSPE™ SAX

Format, amount #/box AttractSPE™ SAX -40µm AttractSPE™ SAX -80µm

1mL, 10mg, 100/pk 100 SAX-100.S.1.10

1mL, 30mg 100 SAX-100.S.1.30 SAX-100.S.1.30GP

3mL, 60mg 50 SAX-50.S.3.60 SAX-50.S.3.60GP

3mL, 100mg 50 SAX-50.S.3.100 SAX-50.S.3.100GP

6mL, 150mg 50 SAX-50.S.6.150 SAX-50.S.6.150GP

6mL, 200mg 50 SAX-50.S.6.200 SAX-50.S.6.200GP

6mL, 500mg 50 SAX-50.S.6.500 SAX-50.S.6.500GP

10mL LRC, 60mg 50 SAX-50.LRC.10.60

12mL, 500mg 25 SAX-25.S.12.500

12mL, 1g 25 SAX-25.S.12.1000

12mL, 2g 25 SAX-25.S.12.2000GP

20mL, 1g 25 SAX-25.S.20.1g

20mL, 2g 25 SAX-25.S.20.2g

96 well Plate, 10mg 1 SAX-1.96W.10

96 well Plate, 30mg 1 SAX-1.96W.30 SAX-1.96W.30GP

96 well Plate, 60mg 1 SAX-1.96W.60 SAX-1.96W.60GP

Reversible 0.7mL, 30mg 50 SAX-50.REV.1.N10

Reversible 0.7mL, 100mg 50 SAX-50.REV.1.F

Reversible 2mL, 225mg 50 SAX-50.REV.2.N10

Disks cartridges (sorbent isa SPE disk)

See page AttractSPE™Disks CartridgesHigh capacity for a minimal elution volume

Page 75: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Mixed-mode SPE for extraction of weakbasic analytesAttractSPE™SCX is a strong cation exchangesorbent interacting with the analytes via amixed mode retention mechanism, ionexchange with strong acid functionalgroups and reversed phase. It particularlysuits for the extraction of weak bases.

Product InformationParticle diameter range : 40 and

60 µm Pore size: 60 ÅSurface area: 600 m2/gIonic capacity: 1meq/gStorage : Ambient temperature

AttractSPE™ SCX

75

Format, amount #/box AttractSPE™ SCX -40µm AttractSPE™ SCX -80µm

1mL, 10mg, 100/pk 100 SCX-100.S.1.10

1mL, 30mg 100 SCX-100.S.1.30 SCX-100.S.1.30GP

3mL, 60mg 50 SCX-50.S.3.60 SCX-50.S.3.60GP

3mL, 100mg 50 SCX-50.S.3.100 SCX-50.S.3.100GP

6mL, 150mg 50 SCX-50.S.6.150 SCX-50.S.6.150GP

6mL, 200mg 50 SCX-50.S.6.200 SCX-50.S.6.200GP

6mL, 500mg 50 SCX-50.S.6.500 SCX-50.S.6.500GP

10mL LRC, 60mg 50 SCX-50.LRC.10.60

12mL, 500mg 25 SCX-25.S.12.500

12mL, 1g 25 SCX-25.S.12.1000

12mL, 2g 25 SCX-25.S.12.2000GP

20mL, 1g 25 SCX-25.S.20.1g

20mL, 2g 25 SCX-25.S.20.2g

96 well Plate, 10mg 1 SCX-1.96W.10

96 well Plate, 30mg 1 SCX-1.96W.30 SCX-1.96W.30GP

96 well Plate, 60mg 1 SCX-1.96W.60 SCX-1.96W.60GP

Reversible 0.7mL, 30mg 50 SCX-50.REV.1.N10

Reversible 0.7mL, 100mg 50 SCX-50.REV.1.F

Reversible 2mL, 225mg 50 SCX-50.REV.2.N10

Disks cartridges (sorbent isa SPE disk)

See page AttractSPE™Disks CartridgesHigh capacity for a minimal elution volume

Page 76: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Reversed phase SPE for extraction ofhydrophobic analytesAttractSPE™DVB is a polystyrene-divinylbenzene copolymer presenting a highhydrophobicity used as a reversed-phase. Itparticularly suits for the extraction ofhydrophobic analytes.

Product InformationParticle diameter range : 40

and 60µmPore size: 60 ÅSurface area: 600 m2/gStorage : Ambient temperature

76

AttractSPE™ DVB

Format, amount #/box AttractSPE™ DVB -40µm AttractSPE™ DVB -80µm

1mL, 10mg, 100/pk 100 DVB-100.S.1.10

1mL, 30mg 100 DVB-100.S.1.30 DVB-100.S.1.30GP

3mL, 60mg 50 DVB-50.S.3.60 DVB-50.S.3.60GP

3mL, 100mg 50 DVB-50.S.3.100 DVB-50.S.3.100GP

6mL, 150mg 50 DVB-50.S.6.150 DVB-50.S.6.150GP

6mL, 200mg 50 DVB-50.S.6.200 DVB-50.S.6.200GP

6mL, 500mg 50 DVB-50.S.6.500 DVB-50.S.6.500GP

10mL LRC, 60mg 50 DVB-50.LRC.10.60

12mL, 500mg 25 DVB-25.S.12.500

12mL, 1g 25 DVB-25.S.12.1000

12mL, 2g 25 DVB-25.S.12.2000GP

20mL, 1g 25 DVB-25.S.20.1g

20mL, 2g 25 DVB-25.S.20.2g

96 well Plate, 10mg 1 DVB-1.96W.10

96 well Plate, 30mg 1 DVB-1.96W.30 DVB-1.96W.30GP

96 well Plate, 60mg 1 DVB-1.96W.60 DVB-1.96W.60GP

Reversible 0.7mL, 30mg 50 DVB-50.REV.1.N10

Reversible 0.7mL, 100mg 50 DVB-50.REV.1.F

Reversible 2mL, 225mg 50 DVB-50.REV.2.N10

Disks cartridges (sorbent isa SPE disk)

See page AttractSPE™Disks CartridgesHigh capacity for a minimal elution volume

Page 77: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 77

SilactSPE™

INORGANIC-BASED SPE

Page 78: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

INORGANIC-BASED SilactSPE™ CARTRIDGES

SilactSPE™ products are inorganic based sorbents SPE cartridges mainlyalumina or modified silica.

78

A very large range of SPE sorbents

SilactSPE™ Silica or Alumina - based SPE cartridges are silica- or aluminabased phases and offer a broad range of chemically modified silica oralumina. This chemistry goes from very polar sorbent (bare silica) tohydrophobic sorbent (end-capped saturated hydrocarbon modified silica)passing through intermediate polarity (for instance, amino modified silica).SilactSPE™ products are Silica-based and alumina-based sorbents availablein different formats including SPE cartridges and 48- & 96-well plates, withdifferent sorbents, and in bed weights up to 10 grams.

Florisilpolar –highly

active –weakly basic

Alumina (A, B, N)

Highly active

SilicaVery polar

Normal phase

C18 Strongly

hydrophobic

Phenylmoderately

hydrophobic

C8 moderately

hydrophobic

Reversedphase based

silica

CyanoCyano propylPolar phase

SiSAXStrong anion exchanger

SiWCXWeak cationexchanger

More polar Silica based phase

PSA primary

secundaryamine

Amino(SiWAX)

Weak anion exchanger

SiSCXStrong cation

exchanger

Page 79: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Strongly hydrophobic and non-polar sorbentIt was recently developed as an innovativeC18 phase characterized by a homogeneouscoverage of the silane on the surface.SilactSPE™C18 particularly suits for theextraction of acidic, neutral and basiccompounds from aqueous solutions, variousorganic compounds from water, and drugsand metabolites from physiological fluids.

Product InformationLoading : 15-17 % CEndcapping : Yes forSilactSPE™ C18,No for SilactSPE™ C18NECSilica type: 60 Å, 500 m2/g,

40-63 µm

79

SilactSPE™ C18

Cartridges format,Sorbent amount #/box SilactSPE™C18 (end capped) SilactSPE™C18 NEC (not end

capped)

1mL, 50mg 100 C18-100.S.1.50 C18nec-100.S.1.50

1mL, 100mg 100 C18-100.S.1.100 C18nec-100.S.1.100

3mL, 200mg 50 C18-50.S.3.200 C18nec-50.S.3.200

3mL, 500mg 50 C18-50.S.3.500 C18nec-50.S.3.500

6mL, 500mg 50 C18-50.S.6.500 C18nec-50.S.6.500

6mL, 1g 50 C18-50.S.6.1g C18nec-50.S.6.1g

10mL LRC, 500mg 50 C18-50.LRC.10.500 C18nec-50.LRC.10.500

12mL, 2g 20 C18-20.S.12.2g C18nec-20.S.12.2gReversible

0.7mL, 260mg 25 C18-25.REV.1.260 C18nec-25.REV.1. 360

Reversible2mL, 1g 25 C18-25.REV.2.1000 C18nec-25.REV.2.1000

96 well plate, 50mg 1 C18-1.96W.50 C18nec--1.96W.50

96 well plate, 100mg 1 C18--1.96W.100 C18nec-1.96W.100

SilactSPE™ C18 end-capped SilactSPE™ C18NEC not end-capped

Page 80: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SilactSPE™ C8 & SilactSPE™ PHENYL

SilactSPE™C8: Moderatelyhydrophobic and non-polar sorbentSorbent C8 is more selective thanSorbent C18 for big compounds suchas PAH, vitamin D, and oils as well asgreasy compounds. It particularlysuits for the extraction of extremelynon-polar compounds.

Product InformationLoading : 12 % CEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63 µm

80

SilactSPE™Phenyl: Moderatelyhydrophobic and non-polar sorbentit particularly suits for the extraction

of non-polar compounds withdifferent selectivities through π-πinteractions including aromaticcompounds and other non-polarphases.

Product InformationLoading : 9 % CEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63 µm

Cartridges format,Sorbent amount #/box SilactSPE™C8 SilactSPE™Phenyl

1mL, 50mg 100 C8-100.S.1.50 Phe-100.S.1.50

1mL, 100mg 100 C8-100.S.1.100 Phe-100.S.1.100

3mL, 200mg 50 C8-50.S.3.200 Phe-50.S.3.200

3mL, 500mg 50 C8-50.S.3.500 Phe-50.S.3.5006mL, 500mg

50 C8-50.S.6.500 Phe-50.S.6.500

6mL, 1g 50 C8-50.S.6.1g Phe-50.S.6.1g10mL LRC, 500mg

50 C8-50.LRC.10.500 Phe-50.LRC.10.500

12mL, 2g 20 C8-20.S.12.2g Phe-20.S.12.2g

Reversible 0.7mL, 260mg 25 C8-25.REV.1. 260 Phe-25.REV. 1.260

Reversible 2mL, 1g 25 C8-25.REV.2.1000 Phe-25.REV.2.1000

96 well plate, 50mg 1 C8--1.96W.50 Phe--1.96W.50

96 well plate, 100mg 1 C8-1.96W.100 Phe-1.96W.100

Page 81: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SilactSPE™ Silica & SilactSPE™ Cyano

81

SilactSPE™Silica : Most polar sorbentIt presents a slightly acidic characterand is used to extract variouscompounds from non-polar solventsthrough hydrogen bonding.

Product InformationSilica type : 60 Å, 500 m2/g, 40-63µm

SilactSPE™Cyano : Moderately polarsorbentIt is used as a normal phase (lesspolar compared to silica). Itparticularly suits for the extraction ofacidic, basic and neutral compoundsfrom aqueous solutions. It is alsoused as a reversed-phase (lesshydrophobic than C8 and C18).

Product InformationLoading : 7 % CEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63 µm

Cartridges format,Sorbent amount #/box SilactSPE™Silica SilactSPE™Cyano

1mL, 50mg 100 Si-100.S.1.50 CN-100.S.1.50

1mL, 100mg 100 Si-100.S.1.100 CN-100.S.1.100

3mL, 200mg 50 Si-50.S.3.200 CN-50.S.3.200

3mL, 500mg 50 Si-50.S.3.500 CN-50.S.3.500

6mL, 500mg 50 Si-50.S.6.500 CN-50.S.6.500

6mL, 1g 50 Si-50.S.6.1g CN-50.S.6.1g

10mL LRC, 500mg 50 Si-50.LRC.10.500 CN-50.LRC.10.500

12mL, 2g 20 Si-20.S.12.2g CN-20.S.12.2g

Reversible 0.7mL 25 Si-25.REV.1.240 for 240mg

CN-25.REV.1. 260 for 260mg

Reversible 2mL 25 Si-25.REV.2.900 for 900mg

CN-25.REV.2.1000 for 1000mg

96 well plate, 50mg 1 Si--1.96W.50 CN--1.96W.50

96 well plate, 100mg 1 Si-1.96W.100 CN-1.96W.100

Page 82: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 82

SilactSPE™Amine (SiWAX): Weakanion exchanger silica-basedsorbentSilactSPE™Amino avoids irreversibleretention of acidic molecules (pKa <3) and particularly suits for theseparation of peptides, drugs andmetabolites from physiological fluids,poly- and monosaccharides andstructural isomers.

Product InformationLoading : 1.6 mmol/gEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63 µm

SilactSPE™PSA: Weak anionexchanger silica-based sorbentLess polar sorbent than SilactSPE™

Amine used for its replacement withanalytes that are too stronglyretained on an amine phase.

Product InformationEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63µm

SilactSPE™ Amine (SiWAX) & SilactSPE™ PSA

Cartridges format,Sorbent amount #/box SilactSPE™ Amine or

SiWAX SilactSPE™ PSA

1mL, 50mg 100 NH2-100.S.1.50 PSA-100.S.1.50

1mL, 100mg 100 NH2-100.S.1.100 PSA-100.S.1.100

3mL, 200mg 50 NH2-50.S.3.200 PSA-50.S.3.200

3mL, 500mg 50 NH2-50.S.3.500 PSA-50.S.3.500

6mL, 500mg 50 NH2-50.S.6.500 PSA-50.S.6.500

6mL, 1g 50 NH2-50.S.6.1g PSA-50.S.6.1g

10mL LRC, 500mg 50 NH2-50.LRC.10.500 PSA-50.LRC.10.500

12mL, 2g 20 NH2-20.S.12.2g PSA-20.S.12.2g

Reversible 0.7mL, 260mg 25 NH2-25.REV.1.260 PSA-25.REV.1.260

Reversible 2mL, 1000mg 25 NH2-25.REV.2.1000 PSA-25.REV.2.1000

96 well plate, 50mg 1 NH2-1.96W.50 PSA--1.96W.50

96 well plate, 100mg 1 NH2-1.96W.100 PSA-1.96W.100

Page 83: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 83

SilactSPE™SiSCX: Strong cationexchanger silica-based sorbentpositively charged with tosic acidmoieties.SilactSPE™SiSCX particularly suits toextract basic molecules (pKa 7-10)

Product InformationLoading : 0.8 mmol/gEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63 µm

SilactSPE™SiWCX: Weak cationexchanger silica-based sorbent withcarboxylic acid.SilactSPE™SiWCX particularly suits toextract strong basic molecules(pKa>9).

Product InformationLoading : 1.6 mmol/gEndcapping : YesSilica type : 60 Å, 500 m2/g, 40-63µm

SilactSPE™ SiWCX SilactSPE™ SiSCX

Cartridges format,Sorbent amount #/box SilactSPE™ SiWCX SilactSPE™ SiSCX

1mL, 50mg 100 SiWCX-100.S.1.50 SiSCX-100.S.1.50

1mL, 100mg 100 SiWCX-100.S.1.100 SiSCX-100.S.1.100

3mL, 200mg 50 SiWCX-50.S.3.200 SiSCX-50.S.3.200

3mL, 500mg 50 SiWCX-50.S.3.500 SiSCX-50.S.3.500

6mL, 500mg 50 SiWCX-50.S.6.500 SiSCX-50.S.6.500

6mL, 1g 50 SiWCX-50.S.6.1g SiSCX-50.S.6.1g

10mL LRC, 500mg 50 SiWCX-50.LRC.10.500 SiSCX-50.LRC.10.500

12mL, 2g 20 SiWCX-20.S.12.2g SiSCX-20.S.12.2g

Reversible 0.7mL, 260mg 25 SiWCX-25.REV.1.260 SiSCX-25.REV.1.260

Reversible 2mL, 1000mg 25 SiWCX-25.REV.2.1000 SiSCX-25.REV.2.1000

96 well plate, 50mg 1 SiWCX-1.96W.50 SiSCX-1.96W.50

96 well plate, 100mg 1 SiWCX-1.96W.100 SiSCX-1.96W.100

Page 84: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 84

SilactSPE™CarbonateGeneral base quencherSilactSPE™Carbonate is the silica-bound equivalent of tetramethylammonium carbonate and is used asa general base to quench a reaction,free base amines in their ammoniumsalt form and to scavenge acids,boronic acids and acidic phenolsincluding HOBt.

SilactSPE™ SiSAX SilactSPE™ Carbonate

SilactSPE™SiSAX: Strong anionexchanger silica-based sorbent usingtrimethyl ammonium moieties.SilactSPE™SiSAX particularly suits toextract acidic molecules (pKa 3-5)

Product InformationLoading : 1.1 mmol/gEndcapping : NoSilica type : 60 Å, 500 m2/g, 40-63 µm

Cartridges format, Sorbentamount #/box SilactSPE™ SiSAX SilactSPE™ Carbonate

1mL, 50mg 100 SiSAX-100.S.1.50 CO3-100.S.1.50

1mL, 100mg 100 SiSAX-100.S.1.100 CO3-100.S.1.100

3mL, 200mg 50 SiSAX-50.S.3.200 CO3-50.S.3.200

3mL, 500mg 50 SiSAX-50.S.3.500 CO3-50.S.3.500

6mL, 500mg 50 SiSAX-50.S.6.500 CO3-50.S.6.500

6mL, 1g 50 SiSAX-50.S.6.1g CO3-50.S.6.1g

10mL LRC, 500mg 50 SiSAX-50.LRC.10.500 CO3-50.LRC.10.500

12mL, 2g 20 SiSAX-20.S.12.2g CO3-20.S.12.2g

Reversible 0.7mL, 260mg 25 SiSAX-25.REV.1.260 CO3-25.REV.1.260

Reversible 2mL, 1000mg 25 SiSAX-25.REV.2.1000 CO3-25.REV.2.1000

96 well plate, 50mg 1 SiSAX-1.96W.50 CO3--1.96W.50

96 well plate, 100mg 1 SiSAX-1.96W.100 CO3-1.96W.100

Page 85: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 85

SilactSPE™Florisil PR (MgO3Si) : PolarsorbentThey present a basic character used toextract non-polar to moderately polarcompounds from non-polar solvents.They particularly suit for the retentionof chlorinated pesticides,polychlorinated biphenyl (PCB’s) andpolysaccharides due to the magnesiumion.Product InformationFlorisil PR type : 150-200 µm

SilactSPE™ Florisil PR SilactSPE™ Dry SilactSPE™Na2SO4/Florisil

Cartridges format,Sorbent amount,

#/box

SilactSPE™ FlorisilPR

1mL, 50mg, 100/pk FloPR-100.S.1.50

1mL, 100mg, 100/pk FloPR-100.S.1.100

3mL, 200mg, 50/pk FloPR-50.S.3.200

3mL, 500mg, 50/pk FloPR-50.S.3.500

6mL, 500mg, 50/pk FloPR-50.S.6.500

6mL, 1g, 50/pk FloPR-50.S.6.1g

10mL LRC, 500mg, 50/pk

FloPR-50.LRC.10.500

12mL, 2g, 20/pk FloPR-20.S.12.2g

Reversible0.7mL, 300mg, 25/pk FloPR-25.REV.1.300

Reversible2mL, 900mg, 25/pk FloPR-25.REV.2.900

96 well plate, 50mg, 1 unit FloPR--1.96W.50

96 well plate, 100mg, 1 unit FloPR-1.96W.100

SilactSPE™Dry: contains sodiumsulfate anhydrous (Na2SO4) inreversible cartridges.

Cart. format,Sorbent amount,

#/boxSilactSPE™ Dry

Reversible0.7mL, 800mg,

50/pk

Na2SO4-50.REV.1.800

Reversible2mL, 2500mg,

50/pk

Na2SO4-50.REV.2.2500

SilactSPE™Na2SO4/Florisil containsan upper layer of sodium sulfateanhydrous (Na2SO4) to dry thesolution and a bottom layer ofFlorisil for the determination ofhydrocarbons in water accordingto DIN-H-53/ ISO 9377-4.

Cart. format,Sorbent amount

#/box

SilactSPE™

Na2SO4 / Florisil

6mL PP, 2g+2g, 50/pk

FloNa2SO4-50.S.6.2g.2g

12mL PP, 3g+3g, 25/pk

FloNa2SO4-25.S.12.3g.3g

Page 86: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 86

Alumina can present either cationic, neutral and acidic character. It is used in asimilar fashion as for the SilactSPE™ Silica. The difference is that Alumina ismore stable at high pH than silica.

SilactSPE™Alumina particularly suit for the retention of aromatic compounds,aliphatic amines and compounds containing electronegative functions.

Product InformationAlumina type : 60 Å, 0.9 g/mL, 50-200 µm

SilactSPE™ Alumina-Acidic, Neutral and Basic

Cartridges format,Sorbent amount #/box SilactSPE™

Alumina AcidicSilactSPE™

Alumina NeutralSilactSPE™

Alumina Basic

1mL, 50mg 100 AluA-100.S.1.50 AluN-100.S.1.50 AluB-100.S.1.50

1mL, 100mg 100 AluA-100.S.1.100 AluN-100.S.1.100 AluB-100.S.1.100

3mL, 200mg 50 AluA-50.S.3.200 AluN-50.S.3.200 AluB-50.S.3.200

3mL, 500mg 50 AluA-50.S.3.500 AluN-50.S.3.500

AluB-50.S.3.500

6mL, 500mg 50 AluA-50.S.6.500 AluN-50.S.6.500 AluB-50.S.6.500

6mL, 1g 50 AluA-50.S.6.1g AluN-50.S.6.1g AluB-50.S.6.1g

10mL LRC, 500mg 50 AluA-50.LRC.10.500

AluN-50.LRC.10.500 AluB-50.LRC.10.500

12mL, 2g 20 AluA-20.S.12.2g AluN-20.S.12.2g AluB-20.S.12.2g

Reversible0.7mL, 700mg 25 AluA-25.REV.1.700 AluN-25.REV.1.700 AluB-25.REV.1.700

Reversible2mL, 2g 25 AluA-25.REV.2.2g AluN-25.REV.2.2g AluB-25.REV.2.2g

96 well plate, 50mg 1 AluA-1.96W.50 AluN-1.96W.50 AluB--1.96W.50

96 well plate, 100mg 1 AluA-1.96W.100 AluN-1.96W.100 AluB-1.96W.100

Page 87: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ Carbon based SPE

Product Vol Sorbent 25 cartridges/box 50 cartridges/box

AttractSPE™

Carbon 6mL 500mg Carb-25.S.6.500 Carb-50.S.6.500

AttractSPE™

Carbon/PSA

3mL 250mg/250mg

CarbPSA-25.S.3.250.250

CarbPSA-50.S.3.250.250

6mL 500mg/500mg

CarbPSA-25.S.6.500.500

CarbPSA-50.S.6.500.500

AttractSPE™

Carbon/Amine 6mL 500mg/500mg

CarbNH2-25.S.6.500.500

CarbNH2-50.S.6.500.500

87

AttractSPE™Carbon

For the extractionof herbicides (EPAmethod 535)

A GraphitizedCarbon Black sorbent. for

absorption of pigments in food and small organic residues in water.

AttractSPE™

Carbon/Amine

For the cleanup of pesticides in food matrices prior to

GC analysis

A two layer sorbents with

Graphitized Black Carbon (GCB) and

Aminopropylmodified silica

sorbents

AttractSPE™

Carbon/PSA

For the cleanup of pesticides in food matrices prior to

GC analysis

A two layer sorbents with

Graphitized Black Carbon (GCB) and

PSA modified silica sorbents

Page 88: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ on-line SPE

88

Page 89: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 89

Product Product reference Numbercolumn

I.D. (mm)

Lenght (mm)

On-line AttractSPE™

HLB columnsOnlineSPE-HLB-1.2.20 1 2.1 20

OnlineSPE-HLB-1.5.20 1 4.6 20

On-line AFFINIMIP® PHENOLICS columns

OnlineSPE-PHE-1.2.20 1 2.1 20

OnlineSPE-PHE-1.5.20 1 4.6 20

On-line AFFINIMIP® ESTROGENS columns

OnlineSPE-EST-1.2.20 1 2.1 20

OnlineSPE-EST-1.5.20 1 4.6 20

For other on-line SPE products, please contact usAFFINISEP can provide you with on-line SPE of all products on demand.

On-line SPE columns

ON-LINE SPE PROCEDURE STEPSSPE technique can be coupled on-line to HPLC for a high sensitivity or forlimited amount of sample. An on-line SPE column containing the SPE sorbentsis coupled. A three steps process is used:

1- Sample injection: The valve is configured with the injector directly in contactwith the on-line SPE column. The sample is injected and goes through the on-line SPE column where the analytes remain.2- Washing: a solution is used to wash out most interferences.3- Analysis: The valve is switched. The analytes are eluted out of the sorbentby the LC mobile phase and transfered into the analytical column for theiranalyses.

ON-LINE SPE – DESCRIPTION AND PRODUCT LIST

Sample injection and washing (1 and 2) Sample elution and analysis (step 3)

Analytical column

Detector

HPLC Pump

SPE column

Sample injectorWaste

Analytical column

Detector

HPLC Pump

SPE column

Sample injectorWaste

Flow Flow

Page 90: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™ SLESupported Liquid Extraction

AttractSPE™ LipRemProteins & lipid Removal

AttractFiltra™ Filtration

90

Page 91: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SPE FOR REMOVAL OF PROTEINS & LIPIDS

91

Cartridge volume SilactSPE™ Double fritted100 cartridges

SilactSPE™ Single fritted100 cartridges

1mL 0-100.S.1.2F 0-100.S.1.1F

3mL 0-100.S.3.2F 0-100.S.3.1F

6mL 0-100.S.6.2F 0-100.S.6.1F

15mL 0-100.S.15.2F 0-100.S.15.1F

25mL 0-100.S.25.2F 0-100.S.25.1F

60mL 0-100.S.60.2F 0-100.S.60.1F

96 well plate – 1 unit 0-1.96W.2F 0-1.96W.1F

SilactSPE™Double fritted & SilactSPE™Single fritted

For the removal of proteins after precipitationSilactSPE™Double fritted & SilactSPE™Single fritted are cartridges withrespectively one or two 20µm PE frits.

AttractSPE™LipRem

For the removal of phospholipids of plasma sampleAttractSPE™LipRem is a sorbent used for the removal of phosphorylcholinelipids from the plasma.

Cartridges format, Sorbent amount #/box AttractSPE™LipRem

1mL, 20mg 100 LipRem-100.S.1.20

3mL, 60mg25 LipRem-25.S.3.50

50 LipRem-50.S.3.50

6mL, 100mg25 LipRem-25.S.6.100

50 LipRem-50.S.6.100

96 well Plate 1 LipRem-1.96W.20

Reversible, 0.7mL, 100mg25 LipRem-25.REV.1.F

50 LipRem-50.REV.1.F

Page 92: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™SLE FOR SUPPORTED LIQUID EXTRACTION

92

Supported Liquid Extraction (a.k.a SLE) is an alternative to LLE to pass from anaqueous media to an organic media without emulsion formation. Thismethod is also useful to remove phospholipids and proteins from biologicalfluids.

AttractSPE™SLE contains an inert sorbent which absorbs water and enables theextraction of analytes with an organic solvent not miscible with water. Thisproduct advantageously replaces the phase transfer using liquid - liquidextraction and inherent problems such as emulsion formation. This process iseasy to automate., with a limited labour, glassware and organic solvent.

3- Extract of molecules of interest with organicsolvents

1 – Load theaqueous solution

2- Wait for absorption of water by the sorbent

AttractSPE™SLE

Cartridge volume Sorbent 25 cartridges/box 50 cartridges/box

1mL 250mg SLE-25.S.1.250 SLE-50.S.1.250

3mL 500mg SLE-25.S.3.500 SLE-50.S.3.500

6mL 1g SLE-25.S.6.1g SLE-50.S.6.1g

15mL 3g SLE-25.S.15.3g SLE-50.S.15.3g

20mL 4.5g SLE-25.S.20.4g SLE-50.S.20.4g

70mL 14.5g SLE-25.S.70.14g

96 well plate – 1 unit 200mg SLE-1.96W.200

Page 93: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractFiltra™ FOR MEMBRANE FILTER CARTRIDGE

93

Designation Membrane Pore size µm 3mL (100/box) 6mL (100/box) 96 filter plate –1unit

AttractFiltra™PES PES

0.2 PES-100.S.3.2 PES-100.S.6.2 PES-1.96W.2

0.45 PES-100.S.3.45 PES-100.S.6.45 PES-1.96W.45

AttractFiltra™PTFE PTFE

0.2 PTFE-100.S.3.2 PTFE-100.S.6.2 PTFE-1.96W.2

0.45 PTFE-100.S.3.45 PTFE-100.S.6. 45

PTFE-1.96W.45

AttractFiltra™PVDF PVDF

0.2 PVDF-100.S.3.2 PVDF-100.S.6.2 PVDF-1.96W.2

0.45 PVDF-100.S.3.45 PVDF-100.S.6.45 PVDF-1.96W.45

AttractFiltra™RC

Regenerated cellulose

0.2 RC-100.S.3.2 RC-100.S.6.2 RC-1..96W.2

0.45 RC-100.S.3.45 RC-100.S.6.45 RC-1.96W.45

AttractFiltra™Nylon Nylon

0.2 NY-100.S.3.2 NY-100.S.6.2 NY-1.96W.2

0.45 NY-100.S.3.45 NY-100.S.6.45 NY-1.96W.45

AttractFiltra™CA

Cellulose acetate

0.2 CA-100.S.3.2 CA-100.S.6.2 CA-1.96W.2

0.45 CA-100.S.3.45 CA-100.S.6.45 CA-1.96W.45

AttractFiltra™ is a filtration cartridges based on the use of a membrane to filtrateand remove particles with vaccuum manifold (ACC-MAN1) or SPE automatesbefore LC analysis.A broad range of membranes is available and can enable a broad range of samplefiltration. Available formats are 3mL, 6mL and 96 microfilter plate.AttractFiltra™PES with a PES membrane (hydrophilic, low protein binding) forwater filtrationAttractFiltra™PTFE with a PTFE membrane (hydrophobic, wide chemicalcompatibility, T resistance) for the filtraton of aggressive solutionsAttractFiltra™PVDF with a PVDF membrane (hydrophobic, wide chemicalcompatibility, T resistance) for the filtraton of aggressive solutionsAttractFiltra™RC with a Regenerated cellulose membrane (hydrophilic, solventresistant, low non specific adsorption) for particle removal in solventsAttractFiltra™Nylon with a Nylon membrane (hydrophilic, high protein, RNA &DNA binding, high surface area) for a wide range of biological preparationsAttractFiltra™CA with a Cellulose Acetate membrane (hydrophilic, low proteinbinding ) for protein filtration

Page 94: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Qcleanup™

Dispersive SPE QuEChERSand extraction salts

94

Page 95: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 95

QuEChERS is a sample pretreatment initially developed by MichelangeloAnastassiades and Steven Lehotay is mainly used for the analysis of multiplepesticides into fruits and vegetables. It is the acronym of Quick, Easy, Cheap,Effective, Rugged ans Safe. Three main methods are currently used the originalmethod, the European standardized method EN 15662 and the AOAC officialmethod 2007.01. Each method required an extraction process with salts and aclean-up process with SPE cartridges or by dispersive SPE.

Qcleanup™ - DESCRIPTION

AFFINISEP supplies all products required to carry out QuEChERS accordingto AOAC or CEN including dispersive SPE products or SPE cartridges.

Add Acetonitrile Mix during 1 minute

Add extraction salts

Centrifuge and collect the supernatant

Purify by dispersive SPE

Mix and centrifuge

Homogenize Sample

Purify by SPE cartridges

ANALYSE

Schematic protocol of sample preparation with QuEHERS method

Extr

actio

n

Clea

n-up

Page 96: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 96

Qcleanup™ DISPERSIVE SPE PRODUCTS

Method Description Nber/box Product reference

For General Fruits & Vegetables

EN 15662150mg MgSO4 + 25mg PSA 100 tubes of 2mL dSPE.EN.GFV.100.2

900mg MgSO4 + 150mg PSA 50 tubes of 15mL dSPE.EN.GFV.50.15

AOAC 2007.01

150mg MgSO4 + 50mg PSA 100 tubes of 2mL dSPE.AOAC.GFV.100.2

1200mg MgSO4 + 400mg PSA 50 tubes of 15mL dSPE.AOAC.GFV.50.15

For Pigmented Fruits & Vegetables

EN 15662150mg MgSO4 + 25mg PSA + 2.5mg CB 100 tubes of 2mL dSPE.EN.PFV.100.2

900mg MgSO4 + 150mg PSA + 15mg CB 50 tubes of 15mL dSPE.EN.PFV.50.15

AOAC 2007.01

150mg MgSO4 + 50mg PSA + 50mg CB 100 tubes of 2mL dSPE.AOAC.PFV.100.2

1200mg MgSO4 + 400mg PSA + 400mg CB 50 tubes of 15mL dSPE.AOAC.PFV.50.15

For Highly Pigmented and Fatty Fruits & Vegetables

EN 15662150mg MgSO4 + 25mg PSA + 7.5mg CB 100 tubes of 2mL dSPE.EN.HPFV.100.2

900mg MgSO4 + 150mg PSA + 45mg CB 50 tubes of 15mL dSPE.EN.HPFV.50.15

AOAC 2007.01

150mg MgSO4 + 50mg PSA + 50mg CB +50mg C18 100 tubes of 2mL dSPE.AOAC.HPFV.100

.2

1200mg MgSO4 + 400mg PSA + 400mg CB + 400mg C18 50 tubes of 15mL dSPE.AOAC.HPFV.50.

15

For Fatty and waxed Fruits & Vegetables

EN 15662150mg MgSO4 + 25mg PSA + 25mg C18 100 tubes of 2mL dSPE.EN.FWFV.100.2

900mg MgSO4 + 150mg PSA + 150mg C18 50 tubes of 15mL dSPE.EN.FWFV.50.15

AOAC 2007.01

150mg MgSO4 + 50mg PSA + 50mg C18 100 tubes of 2mL dSPE.AOAC.FWFV.100.2

1200mg MgSO4 + 400mg PSA + 400mg C18 50 tubes of 15mL dSPE.AOAC.FWFV.50.

15

Qcleanup™ products for dispersive SPE are mixtures of powder in 2mL or 15mLcentrifugation tubes for main scenarios encountered during pesticide analyses.This mixture contains magnesium sulfate anhydrous (MgSO4), primarysecondary amine (PSA), carbon black (CB) or C18.

Page 97: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 97

Qcleanup™ EXTRACTION SALTS

QuEChERSmethods

DescriptionPouches

/ boxProduct

reference

Original method

4g MgSO4

1g NaCl50 EXT.ORL.50

EN 15662

1g Trisodium citrate Dihydrate0.5g Disodium hydrogencitrate

sesquihydrate1g NaCl and 4g MgSO4

50 EXT.EN.50

AOAC 2007.01

1.5g Sodium Acetate and 6g MgSO4

50EXT.AOAC.

50

Qcleanup™ extraction salts are the three main salts mixtures used in

QuEChERS method.

Page 98: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Page 99: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Solid Phase Extraction Solutions

99

2L - 500mL

• AttractSPE™ Disk

• Passive samplers: POCIS, SPATT,

Chemcatcher

Environmental

applications

Page 100: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks for

environmental

applications

Page 101: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks are Solid Phase Extraction Disks for the extractions of abroad range of contaminants. AttractSPE™Disks are thin, dense and uniformSPE disks for retention of targeted analytes without any breakthrough. Ourinnovative SPE disks allow the best interactions with analytes and a maximalflow rates without any channeling.

AttractSPE™Disks

Compared to other Disks available on the market :

üHigher density avoiding channeling

üNo bubbling

üMore diversity on chemistryincluding HLB

üMore diversity in term of capacity(different particle sizes andporosities)

üLarge diversity of applications forpassive sampling (Chemcatcherand POCIS) as well as for proteinand peptide purifications

üCan handle dirty samples

üCompatible with manual andautomated holders

üMultimode or Specific applicationlike disks for Glyphosate

IMPORTANT

FACTAFFINISEP is manufacturer of its own

resins from A to Z (from monomers

to polymers) and can tailor-made

chemistries with different physico-

chemical properties.

101

Page 102: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

lyses AttractSPE™Disks Advantages

q The membrane has a high exposed surface area of active particles

q AttractSPE™ Disks are used to prepare samples of large volumes of water for environmental analysis (Compatible with many EPA methods)

q AttractSPE™ Disks are available in broad diversity of Chemistry, HLB, C18, SDB-XC, SDB-RPS, Anion and cation exchanges as well as multimode HLB and ionics

q Make possible the loading of high volume of water in ashort time with excellent performances

q Usable as Passive sampler such as ChemCatcherq Disks format for contaminants enrichment – 47mm or

90mm

Sorbent particles are tightly enmeshed

no needs to frits

Dense particle packing with no

void space & uniform particle

High separation efficiency

Thin membrane, small bed volume

Can filter large volumes

102

Page 103: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AttractSPE™Disks Environment

Designation DescriptionReference -

47mm -20/pkReference -90mm -

10/pk

AttractSPE™DisksHLB

HLB sorbent SPE-Disks-HLB-47.T1.20

SPE-Disks-HLB-90.T1.10

AttractSPE™DisksC18

C18 sorbent SPE-Disks-C18-47.T1.20

SPE-Disks-C18-90.T1.10

AttractSPE™DisksC18 Polar

C18 Polar sorbent SPE-Disks-C18P-47.T1.20

SPE-Disks-C18P-90.T1.10

AttractSPE™DisksSDB-XC

PS-DVB sorbent SPE-Disks-DVB-47.T1.20

SPE-Disks-DVB-90.T1.10

AttractSPE™DisksSDB-RPS

Modified SDB-RPS sorbent

SPE-Disks-RPS-47.T1.20

SPE-Disks-RPS-90.T1.10

AttractSPE™DisksAnion Exchange SR

SAX sorbent SPE-Disks-AN-47.T1.20

SPE-Disks-AN-90.T1.10

AttractSPE™DisksCation Exchange SR

SCX sorbent SPE-Disks-CAT-47.T1.20

SPE-Disks-CAT-90.T1.10

AttractSPE™DisksOil & Grease

For oil and grease SPE-Disks-OIL-47.T1.20

SPE-Disks-OIL-90.T1.10

AttractSPE™DisksChelating

For multivalent metal SPE-Disks-MET-47.T1.20

SPE-Disks-MET-90.T1.10

AttractSPE™DisksSAX-HLB

SAX-HLB mixture SPE-Disks-SAX-HLB-47.T1.20

SPE-Disks-SAX-HLB-90.T1.10

AttractSPE™DisksHigh Spectrum

Mix HLB-WCX-WAX for non-targeted

screening

SPE-Disks-screening1-

47.T1.20

SPE-Disks-screening1-90.T1.10

AttractSPE™DisksHigh Spectrum

Mix HLB-SCX-SAX for non-targeted

screening

SPE-Disks-screening2-

47.T1.20

SPE-Disks-screening2-90.T1.10

AFFINIMIP®SPE DisksPicolinic Herbicides

Based on AFFINIMIP®SPE

Picolinic herbicides for extraction of picloram

Clopyralid, Aminopyralid

SPE-Disks-PICO-47.T1.20

SPE-Disks-PICO-90.T1.10

AFFINIMIP®SPE DisksEstrogens

Based on AFFINIMIP®SPE

Estrogens

SPE-Disks-EST-47.T1.20

SPE-Disks-EST-90.T1.10

103

Page 104: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 104

AttractSPE™ Disks Manifolds and accessories

AttractSPE™ disks ManifoldsOne-, three- or six-station filtration manifoldsallow the simultaneous extractions of several 1-L samples on a very simple and easy-to-handleway. The manifold is a very compact stainlesssteel device with a filtration glassware. Eachstation is controlled through an independentflow control valve.Manifolds 47mm and 90mm

25mm, 1µm, 50/pk PF-GF-50.T1.25.1

25mm, 3µm, 50/pk PF-GF-50.T1.25.3

47mm, 1µm, 50/pk PF-GF-50.T1.47.1

47mm, 3µm, 50/pk PF-GF-50.T1.47.3

Designation Reference

AttractSPE™ disks Manifolds -1 station - 47mm ACC-DISKSPE-G47-1

AttractSPE™ disks Manifolds -3 stations - 47mm ACC-DISKSPE-G47-3

AttractSPE™ disks Manifolds -6 stations - 47mm ACC-DISKSPE-G47-6

AttractSPE™ disks Manifolds -1 station - 90mm ACC-DISKSPE-G90-1

AttractSPE™Prefilter Glassfiber

90mm, 1µm, 50/pk PF-GF-50.T1.90.1

90mm, 3µm, 50/pk PF-GF-50.T1.90.3

100mm, 1µm, 50/pk PF-GF-50.T1.100.1

100mm, 3µm, 50/pk PF-GF-50.T1.100.3

AttractSPE™Prefilter Glassfiber are required ontop of AttractSPE™ Disks to prevent cloggingwhen loading water rich of suspended particles

Page 105: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

POCIS

SPATT

Chemcatcher

105

Passive sampling enables the monitoring of contaminants in water(surface water, groundwater, coastal water...) for a short (at least 7days) to long period (with an average field deployment of one month)for which no power, maintenance and supervision is required. Anaverage of the concentration of collected contaminants is measuredin the laboratory.

Passive Sampling Solutions

Page 106: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Advantages of Passive Sampling

q Can generate a time-weighted average (TWA)concentration of the contaminants in waterqDeployable in harsh conditionsqNo a priori preparation or supervisionqVery simple use

How is made it? Example of a POCIS

PASSIVE SAMPLING POCIS, SPATT, Chemcatcher

Passive Samplers and Applications

POCIS

Polar OrganicChemical IntegrativeSampler

SPATT

Biotoxin tracking

Chemcatcher

Micropollutantsand Metals

106

Page 107: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Drug residues•Carbamazepine•Sulfamethoxazole•Diclofenac•Propranolol•Erythromycin•Tetracycline•…

Pesticides•Glyphosate & AMPA•Aminopyralid,

Clopyralid, Picloram•Atrazine & derivatives•Diuron•…

Other contaminants•Caffeine•PFOS, PFOA•Biocides•PAHs•Biotoxins

Broad range of applications for your sample preparation

Hormons and EDCs• Natural & synthetic

Estrogens• Bisphenols & analogs• Phenolics• …

The sorbent collects the contaminant(s) in water. The organic compounds arethen extracted from the sorbent in the POCIS, following a SPE procedure andanalyzed using classical analytical methods by HPLC, and LC-MS, ....

POCIS, SPATT,Chemcatcher

Collect of analytes by the passive sampler on the field

Analytes extraction by SPE or membranes

QUANTIFICATIONby HPLC, LCMS or any

other analytical method

Steps from water to analysis

107

Passive Sampling

Page 108: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Passive samplers

POCIS families

• AttractSPE™ POCIS HLB for pharmaceutical drug residues• AttractSPE™ POCIS Pesticides for pesticides• AFFINIMIP® POCIS GLYPHOSATE for Glyphosate and AMPA• AFFINIMIP® POCIS EDC for the retention of Phenolic endocrine

disrupters such as natural/synthetic estrogens, Bisphenols...

Our POCIS with PRCPerformance and reference compound (PRC) is acompound not present in the environment (e.g., adeuterated molecule), which is spiked in the sorbent phaseof the POCIS before its exposure as internal standards.

AttractSPE™ SPATT Biotoxins

AttractSPE® SPATT Biotoxins is used to evaluate the contaminationof shellfish with biotoxins in seawater such as Pectenotoxin,Yessotoxin, Okadaic acid/ Dinophysistoxin and Azaspiracids.

Do you know ?AFFINISEP provides a complete range of SPE Disks

suitable for Chemcatcher. use (see page SPE Disks

for more information)

108

Page 109: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Designation Definition Composition Reference

AFFINIMIP® POCIS

GLYPHOSATE

POCIS containing AFFINIMIP®GLYPHOSATE - AMPA for theretention of glyphosate andAMPA

1 POCIS POCIS.GLY.90.55.A.1

Kit of 10 POCIS + emptyfritted cartridges

POCIS.GLY.90.55.kit.10

AFFINIMIP® POCIS EDC

POCIS containing AFFINIMIP®Estrogens and AFFINIMIP®Bisphenols for the retention ofendocrine disrupters such asnatural/synthetic estrogens,Bisphenols...

1 POCIS POCIS.EDC.90.55.A.1

Kit of 10 POCIS + emptyfritted cartridges

POCIS.EDC.90.55.kit.10

AttractSPE™ POCIS

Pesticides

POCIS containing mixture ofsorbent for the retention ofseveral pesticides

1 POCIS POCIS.PEST.90.55.A.1

Kit of 10 POCIS + emptyfritted cartridges

POCIS.PEST.90.55.kit.10

Kit of 1 POCIS with a sorbentcontaining DIA as PRC- 3 cartridges containing thesorbents withDésisopropylatrazine (DIA) d5- empty fritted cartridges

POCIS.PEST.90.55.ki t.1.DIA

AttractSPE™ POCIS HLB

POCIS containing Attract HLBfor the retention ofpharmaceutical drug residues

1 POCIS POCIS.HLB.90.55.A.1

Kit of 10 POCIS + emptyfritted cartridges

POCIS.HLB.90.55.kit.10

Kit of 1 POCIS with a sorbentcontaining DIA as PRC- 3 cartridges containing thesorbents withDésisopropylatrazine (DIA) d5- empty fritted cartridges

POCIS.HLB.90.55.kit.1.DIA

AFFINIMIP® POCIS PAHs

POCIS for the retention ofPAHs

1 POCIS POCIS.PAHs.90.55.A.1

Kit of 10 POCIS + emptyfritted cartridges

POCIS.PAHS.90.55.kit.10

Passive sampling PRODUCT LIST

109

Several kits are available with or without a performancereference compounds (PRC) to correct for in situ exposureknown to affect uptake rates. These kits also include emptyfritted cartridges to make easiest the extraction step of thecontaminants.

Page 110: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Designation Definition Composition Reference

CANISTER – 3 POCIS Canister for 3 POCIS . Requiresa holder 1 canister CAN-3P.A.1

HOLDER – 3 POCIS Holder for 3 POCIS 1 holder HOLD-3P.A.1

CANISTER AND HOLDER FOR 3

POCIS

1 Canister and 1 holder for 3POCIS

1 canister and 1holder CH-3P.A.1

HOLDER – 3 POCIS

110

CANISTER – 3 POCIS

AttractSPE™ SPATT

Designation Definition Composition Reference

AttractSPE™ SPATT

BIOTOXINS

SPATT containing HP-20sorbent for theretention of biotoxins.Nylon mesh membrane

1 SPATT Biotoxins SPATT.BIOTOX.1

Passive sampling PRODUCT LIST

Do you know ?AFFINISEP provides a complete range of SPE Disks

for Chemcatcher. (see AttractSPE™ Disks for

environmental applications for more information)

AFFINISEP provides a complete set of accessories for the use of Passivesampler.

Page 111: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SPE ACCESSORIES

Positive Pressure Manifolds

Vacuum Manifold

Mini Vap

Pump

111

Page 112: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com 112

AttractSPE™ Manifolds

AttractSPE™Positive Pressure

Manifold

is a Solid Phase Extraction Manifold using

positive pressure to push the liquid through

the SPE tips, cartridges or the 96-well plates

simultaneously. This process confers some

very interesting advantages to this product

in term of repeatability.

Description Reference

24-position with tips MPP-Tips-KIT

96-position for 96 SPE well plate MPP-96W-KIT

24-position, 1 mL MPP-1ML-KIT

24-position, 3 mL MPP-3ML-KIT

15-position, 6 mL MPP-6ML-KIT

Manifold unit and kits

Page 113: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Vacuum Manifold

ACC-MAN1 Like all chromatography techniques, Use of SPEcartridges needs a precise control of flow ratefor maintaining reproducible extractions. SolidPhase extraction Vacuum Manifold allows you tocontrol the flow and to process up to 12 (12-portversion) or 24 (24-port version) AFFINIMIP® SPEsamples simultaneously, to gain significantlytime during sample preparation steps.

Mini PUMP ACC-PUMP Mini diaphragm vacuum pump for solid phaseextraction experimentsØ5.5L/minØ~120 torr vacuumØOil-freeØportable

Vacuum pump trap

ACC-TRAP SPE Vacuum pump trap kit

Installed between the manifold and the vacuumpump, it collects all liquids that are aspiratedpreventing contamination of the vacuum pumpwith a capacity of 1L.

Vacuum SPE Manifold and ACCESSORIES

113

AttractSPE™Vacuum Manifold

very flexible, allows you to control the flow

and to process up to 12 or 24 samples

simultaneously, to gain significantly time

during sample preparation steps.

Page 114: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

SPE ACCESSORIES

114

SPE Accessories Designation Definition Reference

Manifold SPE Vacuum Manifold 12-port model ACC-MAN1

SPE Adapter & Reservoir kit

SPE Adapter & Reservoir kit

Kit of 12 reservoirs 60ml and adapters for use with1,3 & 6 mL cartridges

ACC-AR1

Mini-Vap Mini Evaporator / Concentrator

6 port Mini-VapEvaporator/Concentratorfor use with 1 to 250mL containers

ACC-VAP1

Mini PUMP Mini vacuum pumpLaboport diaphragmvacuum mini pump, 5.5L/min

ACC-PUMP

Vacuum pumptrap

SPE Vacuum pumptrap kit 1L trap kit ACC-TRAP

SPE ACCESSORIES – Product list

SPE Adapter & Reservoirkit

ACC-AR1 Tube adapters serve to pile one SPE tube on topof another to provide different selectivities. Alarger empty syringe barrel can be stacked ontop of a smaller SPE tube to act as a larger loadreservoir. Or, they can serve as an adapter forpositive pressure methods (e.g. from a syringeor air/ N2 line).

Mini-Vap ACC-VAP1 The 6-Port Mini-Vap concentrator/evaporatorprocesses six vials at one time. The Mini-Vapincludes a needle valve for fine metering of airor nitrogen drying gas.

Page 115: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

Examples of

SPE applications

115

Page 116: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES SPE product MATRICES

Multimycotoxins

Aflatoxins, Ochratoxin A, HT-2, T-2, Fumonisins, Zearalenone,Deoxynivalenol

AFFINIMIP® SPEMultimyco LCMSMS

Cereals

Fumonisins AND ZearalenoneAFFINIMIP® SPEFumoZON

Maize, Maize-basedbaby food

Single Mycotoxin

Patulin AFFINIMIP® SPE PatulinAll Apple-based products(Juice, puree,concentrate…)

ZearalenoneAFFINIMIP® SPEZearalenone

Maize, Wheat, Cereal-based baby food, Rice,Edible corn oil

Ochratoxin AAFFINIMIP® SPEOchratoxin A

Wheat, Maize, Pepper,Paprika, Red and WhiteWine

Deoxynivalenol (DON)AFFINIMIP® SPEDeoxynivalenol

Wheat, Maize, Oat

Endo

crin

e Di

srup

tor

Estrone, 17α-Estradiol, 17β-Estradiol, Estriol, 17α-Ethinylestradiol

AFFINIMIP® SPEEstrogens

Water, Serum, Plasma

Bisphenol A, Bisphenol AP,Bisphenol AF, Bisphenol B,Bisphenol S, Bisphenol F…

AFFINIMIP® SPEBisphenols

A broad variety of liquidand solid foods

ParabensAFFINIMIP® SPEPhenolics

Shampoo, cream

Phenolic compoundsAFFINIMIP® SPEPhenolics

Food matrices

Bisphenols & Alkyl phenols AttractSPE™Disks C18 Water

Endocrine disruptors AttractSPE™Disks HLB Water

Drug

Res

idue

s

Amphetamine,Methamphetamine, MDA, MDMA,MDEA

AFFINIMIP® SPEAmphetamines

Serum, Urine

Zeranol, Zearalanone, α and βZearalanol, α and β Zearalenol,Resorcylic acid lactones

AFFINIMIP® SPEZeranol Residues

Urine, Plasma

ChloramphenicolAFFINIMIP® SPEChloramphenicol

Honey, Urine, Shrimp

TamoxifenAFFINIMIP® SPETamoxifen

Urine

EXAMPLES OF SPE APPLICATIONS

116

See our application notebook for more applications and details.

Page 117: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES SPE product MATRICESAn

tibio

tics a

nd D

rugs

resi

dues

Nicotine, Procainamide AttractSPE™ HLB UrineCaffeine AttractSPE™ HLB Urine, WaterPropranolol AttractSPE™ HLB Urine, WaterTetracyclines - Tetracycline, Oxytetracycline,Chlortetracycline, Doxycycline

AFFINIMIP® SPETetracyclines

Milk

Sulfonamides – Sulfadimethoxine ,Sulfamethoxypyridazine… AttractSPE™ SCX Milk

Caffeine, Acetaminophen, Diclofenac,Ibuprofen, Ketoprofen, Naproxen,Carbamazepine

AttractSPE™ HLB Waste water, water

Antibacterial Aminoglycosides - -Streptomycin, Dihydrostreptomycin,… AttractSPE™ HLB Tissue, Milk

Antibiotics – Quinolones, Macrolides,Lincosamides, Sulfonamides, Penicillins,Cephalosporine, Pleuromutilins, Diaminopyrimidine derivatives

AttractSPE™ HLB Tissue, Milk

NSAID (Non Steroidal Anti inflammatorydrug) - Salicylic acid, Phenylbutazone,Flunixin, Tolfenamic acid, Meloxicam,Desoximetasone, Ketoprofen

AttractSPE™ HLB Tissue

Penicillin based antibacterials - Ampicillin,Amoxicillin… AttractSPE™ HLB Tissue

Glucocorticoids - Cortisone, Corticosterone,Aldosterone, Betamethasone,Dexamethasone, Flumethasone, Prednisone,Prednisolone, Methylprednisolone

AttractSPE™ HLB Tissue

Erythromycin and Clindamycin AttractSPE™ HLB TissuePraziquantel and Tiamulin AttractSPE™ HLB TissueCephalexin AttractSPE™ HLB FishQuinoxaline-2 -carboxylic acid and 3-methylquinoxaline-2-carboxylic acid AttractSPE™ SAX

Muscle, Liver, Kidneys

Vancomycin AttractSPE™ SCX FishValnemulin and Tiamulin AttractSPE™ HLB Fish

Phenolic compounds AFFINIMIP® SPE Phenolics

biological matrices

Hormons, sex steroids, Pharmaceuticalcompounds

AttractSPE™DisksHLB

Water

Pharmaceutical compounds and analytescontaining carboxylic acid groups

AttractSPE™ Disks Anion Exchange - SR Water

EXAMPLES OF SPE APPLICATIONS

117

Page 118: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES SPE product MATRICES

Pest

icid

es –

Herb

icid

es -

Bioc

ides

Glyphosate, AMPA AFFINIMIP® SPE Glyphosate Water

Aminopyralid, Clopyralid, PicloramAFFINIMIP® SPE PicolinicHerbicides

Water,Compost,Soil

16 common pesticides - Linuron, Iprodione,Desisopropylatrazine, Desethylatrazine, Aldocarb,Simazine, Carbofuran, Metalaxyl, Atrazin, 2, 4-D,Metazachlor, Dicloran, Phenmedipham,Procymidone, Fenitrothion, Vinclozolin

AttractSPE™ HLB Water

Triazine Herbicides - Simazine, Cyanazine,Atrazine… AttractSPE™ HLB Water

Acetamide Herbicides - Metolachlor andmetabolites, Alachlor… AttractSPE™ HLB Water

Fungicides - Carbendazim, Thiabendazole AttractSPE™ SCX Fruit JuiceOrganotin compounds SilactSPE™Organotin Water, soilsPesticides by GC-MS : Metamidophos,Dichlorvos, Acephate, Trifluralin, Diazinon,Chlorothalonil, Dimethipin, Vinclozoline, Methylparathion, Methyl primophos, Triadimenol-1,DDE, Cypermethrin-3, Difenoconazole-1,Imibenconazole, Tebuthiuron, Bromacil…

AttractSPE™

Carbon/PSAFood matrices

Benzidine & Nitrogen-containing PesticidesAttractSPE™DisksC18 EPA 553.1

Chlorinated acids AttractSPE™DisksSDB-XC EPA 515.2

Endothall

AttractSPE™DisksHLB AttractSPE™DisksC18AttractSPE™ Disks Anion Exchange - SR

EPA 548; EPA548.1 Rev. 1

Nitrogen- & Phosphorus-Containing Pesticides AttractSPE™DisksC18 EPA 507

Organochlorine Pesticides

AttractSPE™DisksHLB AttractSPE™DisksC18

EPA 8081.EPA 608

Organophosphorus Pesticides AttractSPE™DisksC18

EPA 1614;EPA 1657

EXAMPLES OF SPE APPLICATIONS

118

See our application notebook for more applications and details.

Page 119: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES SPE product MATRICES

PAHs

–PO

Ps –

Perf

luor

inat

edco

mpo

unds

Perfluorinated compounds (Perfluorobutanoicacid (PFBA), Perfluoropentanoic acid (PFPeA), Perfluorohexanoic acid (PFHxA), Perfluoroheptanoic acid (PFHpA), Perfluorooctanoic acid (PFOA), Perfluorononanoic acid (PFNA),Perfluorodecanoic acid (PFDA),Perfluorotetradecanoic acid (PFTA),Perfluorobutanesulfonic acid (PFBS),Perfluorohexane sulfonic acid (PFHxS),Perfluorooctanesulfonic acid (PFOS)

AttractSPE™ WAX-PFC

Water

Hydroxylated Polycyclic Aromatic Hydrocarbons- 2-Naphtol, 2-Hydroxyfluorene, 9-Phenanthrol…

AFFINIMIP® SPE Phenolics

Contaminated soils

PBDEs, Dioxins & Furans, PAHs

AttractSPE™DisksHLBAttractSPE™DisksC18

Water, EPA 1613; EPA 625

PAHs AttractSPE™DisksC18 EPA 550.1

PCBs

AttractSPE™DisksHLB AttractSPE™DisksC18

EPA 8082;EPA 1668

Polycyclic Aromatic Hydrocarbons (PAH)

AFFINIMIP® SPE PAHs

Fats and oil

AttractSPE™ HLB Waste water

SilactSPE™ CN/SiOH soil

Phen

olic

s Guaïacol AFFINIMIP® SPE Phenolics

Wines, water

Carnosic acid AFFINIMIP® SPE Phenolics

Meat, water

Hydroquinone AFFINIMIP® SPE Phenolics

Water

EXAMPLES OF SPE APPLICATIONS

119

See our application notebook for more applications and details.

Page 120: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES SPE product MATRICES

Ions

rem

oval

Transition metals ions AttractSPE™ IDA Aqueous solution

Removal of anionic contaminants andneutralization of highly acidic samples AttractSPE™ SAX-HCO3 Aqueous

solutionsRemoval of alkaline earth and neutralizationof basic samples AttractSPE™ PS-H Aqueous

solutionsRemoval of Halides ions (chloride, iodide,bromide) AttractSPE™ PS-Ag Aqueous

solutions

Removal of sulfate ions AttractSPE™ PS-Ba Aqueous solutions

Removal of WATER – drying SilactSPE™ Dry Organic solutions

Biol

ogic

al a

pplic

atio

n

Removal of phospholipids AttractSPE™ LipRem plasma

Removal of precipitated proteins SilactSPE™ Doublefritted & Single fritted

Aqueous solutions

Supported liquid extraction SilactSPE™ SLE Aqueous solutions

NNAL (biomarker of smokers) AFFINIMIP® SPE NNAL Urine

Dopamine, Noradrenaline, Adrenaline, ... AFFINIMIP® SPECatecholamines Plasma, Serum

Metanephrine, Normetanephrine and3-Methoxytyramine, ...

AFFINIMIP® SPEMetanephrines Plasma, Serum

Fractionation and desalting of peptides andproteins

AttractSPE™ Disks Tips– StagetipsAttractSPE™ Disks SpinAttractSPE™ Disks 96plateAttractSPE™ Disks

Cartridge

Proteins digest, serum, urine, biological fluids

Mis

cella

neou

s

Melamine AttractSPE™ SCX Milk, foodCyanuric acid AttractSPE™ SAX MilkARTIFICIAL SWEETENERS - Acesulfame,Aspartame, Cyclamate, Neohespiridinedihydrochalcone, Saccharin, Sucralose

AttractSPE™ HLB Water

COCAINE AND MAIN METABOLITES -Cocaine, benzoylecgonine and ecgoninemethyl ester

AttractSPE™ HLB Waste water

Unknown and not identified contaminantsand metabolites

AttractSPE™LargeSpectrum (Non- targetscreening)

Waste water

Hydrocarbons in water (ISO9377-4) SilactSPE™ Na2SO4 /Florisil water

EXAMPLES OF SPE APPLICATIONS

120

Page 121: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

ANALYTES EPA METHODS SPE product

Extr

actio

n of

con

tam

inan

ts in

wat

er w

ith h

igh

flow

rate

Acids and Base/Neutrals including PCBs EPA 625 AttractSPE™Disks HLB

Amines AttractSPE™ Disks Cation Exchange - SR

Benzidine & Nitrogen-containing Pesticides EPA 553.1 AttractSPE™Disks C18

Carbonyl Compounds EPA 8315 AttractSPE™Disks HLB AttractSPE™Disks C18

Carbonyl Compounds & Formaldehyde EPA 554 AttractSPE™Disks C18Chlorinated acids EPA 515.2 AttractSPE™Disks SDB-XCChlorinated Pesticides EPA 508.1 AttractSPE™Disks C18Dioxins & Furans EPA 1613 AttractSPE™Disks C18

Endothall EPA 548; EPA 548.1Rev. 1

AttractSPE™Disks HLB AttractSPE™Disks C18AttractSPE™ Disks Anion Exchange - SR

Explosives Residues (HDX, RDX) AttractSPE™Disks SDB-RPS

Haloacetic Acids and Dalapon EPA 552.1 Rev.1 AttractSPE™ Disks Anion Exchange - SR

Nitroaromatics & Nitramines EPA 8330 AttractSPE™Disks HLB Nitrogen- & Phosphorus-ContainingPesticides EPA 507 AttractSPE™Disks C18

N-Methylcarbamate EPA8318 AttractSPE™Disks HLB

Oil & grease AttractSPE™ Disks Oil & Grease

Organic Compounds EPA 525 AttractSPE™Disks C18

Organochlorine Pesticides EPA 8081. EPA 608 AttractSPE™Disks HLB AttractSPE™Disks C18

Organophosphorus Pesticides EPA 1614; EPA 1657 AttractSPE™Disks C18PAHs EPA 550.1 AttractSPE™Disks C18

PCBs EPA 8082; EPA 1668 AttractSPE™Disks HLB AttractSPE™Disks C18

Phthalate Esters EPA 8061 AttractSPE™Disks C18Phthalate & Adipate Esters EPA 506 AttractSPE™Disks C18

Phenylurea compounds EPA 532 AttractSPE™Disks HLB AttractSPE™Disks C18

Semivolatile Organic Compounds EPA 8270 AttractSPE™Disks HLB Hormons, sex steroids, PAHs, PPCPs,Pharmaceutical compounds, Endocrinedisruptors

AttractSPE™Disks HLB

Bisphenols & Alkyl phenols, PBDEs, Dioxins &Furans, Phthalates, Herbicides, PAHs,Carbaryl, Microcystins

AttractSPE™Disks C18

Pesticides, Pharmaceutical compounds andanalytes containing carboxylic acid groups

AttractSPE™ Disks Anion Exchange - SR

EXAMPLES OF AttractSPE™ Disks APPLICATIONS

121

Page 122: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

CUSTOM-MADE PRODUCTS&

PRIVATE LABEL SERVICES

122

Food / Feed Safety

Environment

Cosmetics

Life Science

• Development ofcustom products

• Private labelling ofexisting products

• Customization ofexisting products

Page 123: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINISEP offers full services for the design and synthesis of polymerscomplying with your specifications.

With fully integrated technology platforms in polymer and analyticalchemistry, AFFINISEP has been partner in more than 56 projects and helps itscustomers by innovative solutions for their complexes challenges.

AFFINISEP has developed a library of monomers giving a family of selectivestationary phases based on its proprietary technology, which have shown astrong potential for the extraction and purification of various compounds.

123

CUSTOM-MADE PRODUCTS & SERVICES

Why trusting AFFINISEP? AFFINISEP supplies

• The most comprehensive bank of sorbents •From Silica to Polymers•From conventional to very selective •MIPs, Reversed-phase, ionic exchange, etc…

•Our Expertise on MIP, sample preparation, SPE protocol and detection kit development•Quick and efficient development•Reactivity

Custom-made

solutions

SPE for analytical

applications

SPE for radiopharma

MIPdevelopment

Custom-made formats

Page 124: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

If you need the development of new polymer for your application, pleasesend us an email to [email protected] or describe your needs usinghttps://www.affinisep.com/technical-and-customer-support/technical-support/ You can describe your application and our scientists will shortlyevaluate your queries before contacting you as soon as possible.

124

Procedure for custom-made polymer phase

STEP 1

STEP 2

STEP 3

CustomerFe

edba

ck a

nd o

ptim

isatio

n

•Screening

• Elaboration ofapplication protocol• Delivery ofsamples/ prototypesto customer forvalidation

• Scale-up• QC report

Bulk material, SPE cartridgesor HPLC columns

No matter if we run a short term project (2-3 days) or long term project ( 4 to6 months) we always follow a well-established procedure. The followingscheme describes an example of a procedure for the development of acustom-made product based on our customer’s requirements.

After signing of Confidential Disclosure Agreements (CDA), key data areexchanged. A quotation based on our experience in separation scienceincluding a process sheet is developed. During the whole procedure, apermanent feedback is established with you.

PROJECT DEVELOPMENT

Step 1: We offer you a screening of ourlibrary which consists of several hundredsAFFINISEP phases to find the suitable one foryour separation problem. The knowledge ofthe structure of the target substance, itsfunctional groups and the solubility data giveus valuable hints for the choice of thescreening phases.

Step 2: For the selected phase, a protocol isimplemented for your application. Thensamples and / or prototypes are delivered toyou for testing, evaluation and validation.

Step 3: When the selected phase suits yourapplication and has been validated, a scale-upis planned. A QC report is delivered with theproduct. The format of the product iscorrelated to your application and can be bulkmaterial, SPE cartridges, HPLC columns etc…

Page 125: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

Order onwww.affinisep.com

AFFINISEP offers a range of options that enable you to take advantage ofour technology and production capacity to provide the latest products intoyour own portfolio.

We work with you to provide tailored solutions that meet your specificrequirements:

125

PRIVATE LABEL SERVICES

Why trusting AFFINISEP? • Significant R&D savings using our ready to use kits

• Benefit from our Expertise Quick and efficient development

• Dedicated technical support

• Ensure product quality made in France

• Ensure product availability by buying from manufacturer

• Ensure confidentiality

OEM brandedpackaging

OEM branded User Guides & COA

Product customisation

White box-brandedsolution

Others

Page 126: SAMPLING & SAMPLE PREPARATION CATALOG...Sampling and sample preparation are the key steps in trace analysis for analytical chemist. As specialist in this field, AFFINISEP supplies

AboutAFFINISEP is a worldwide expert in sample preparation applications.AFFINISEP is dedicated to the development of analytical applications in variousfields such as water, biological fluids, food, feed analysis and proteomics with acomplete set of products and services for sample preparation.

Analytical chemists can find any solution for sample preparation, selectiveextraction and sample clean-up needs in various sectors: food and feedsafety and quality, life science and quality control, clinical diagnosis,environment and doping.In addition, proteomics users can find a complete set of microelutionproducts for protein/peptides fractionation or desalting.

Brands

AFFINIMIP SPE™AttractSPE™

SilactSPE™…

Applications

Sample PreparationPassive SamplingFiltrationMicroextraction of peptides/proteins

Matrices

Food, Feed, Soil, Oil, Water,

Biological fluids,

Proteolytic digestion

For any order, please, choose one of the following ways:

v On our website : www.affinisep.comFind all our references and benefit from a FAST and SIMPLE process !

vBy email: v [email protected]

Information about new products or new matrices: vNewslettersStay up-to-date on AFFINISEP’s latest innovations by subscribing to our newsletter,delivering new information straight to your inbox ! Register on our website.

ORDERING INFORMATION

THE ART OF MAKING SAMPLE PREPARATION EASIER