sample its working drawings - nj
TRANSCRIPT
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
CCTV COMMUNICATION NETWORK
ASSIGNMENT TABLE
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
SAMPLE BLOCK-DIAGRAM NOTES :
1. Block diagram presents a proposed system solution.
See cabinet wiring diagrams for details.
2. CCTV Composite cable consists of RG59, two shielded
twisted pairs, power conductors
3. Only one "Blue-White" pair is used for telephone connection.
All the others are not connected.
4. Indicated camera addresses correspond to video switcher
ports at TOC-N and TOC-S
5. Each DMS, CCTV and DMS controller cabinet is powered by
120VAC provided by local power unitlity
6. Existing AD Video Switching System as shown includes switching
and expansion chassis, CPU, Code converters,keyboards and
interconnecting cables.
CCTV BLOCK DIAGRAM
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
TEL- Telephone Number
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
TOC -SOUTH , Cherry Hill
RG59 CABLES (VIDEO)
TOC -SOUTH , Cherry Hill
RG59 CABLES (VIDEO)
ITS-17
RT. 42 SB, MP 6.4 @ AC EXPSWY
ITS-20
RT. 55 SB, MP. 58.9 @ DEPTFORD CENTER
RD
ITS-18
I-295 NB, MP. 65.27 @ SLOAN AVE.
24 PORT 10/100
Ethernet Switch
Nextiva system
ITS-13
RT. 37, MP 0.61 @ COLONIAL DRITS-14
ITS-15
ITS-16
RT. 42 SB, MP 11.54 @ RT. 41
Comm. Hub
Existing
local
AD switch
Existing AD232
Expander
6 Video Decoders
AD-Pelco translator
1 2 3 4 5 6
DATA
Fiber
Fiber
M Cabinet
Remote
Data
Port
M Cabinet
DSL MODEM
Remote
Data
Port
M Cabinet
DSL MODEM
SURGE
PROTECTORS
Remote
Data
Port
M Cabinet
FIOS MODEM
Remote
Data
Port
Fiber
VIDEO
M Cabinet
Remote
Data
Port
P/P
M Cabinet
Remote
Data
Port
P/P
Cabinet
Remote
Data
Port
P/P
M Cabinet
AD232-PELCO
TRANSLATOR
PDU / Surge Protection
Remote
Data
Port
ITS-19
RT. 29, MP 6.18 @ SULLIVAN WAY
Ex
ist.
Patc
h
pan
el
Telephone Cable
75’ Pole
40’ Pole 75’ Pole 75’ Pole
Composite Cable Composite Cable Composite Cable
Telephone Cable
Composite Cable
Composite Cable
40’ Pole
Co
mp
osit
e C
ab
le
Composite Cable Composite Cable
75’ Pole
40’ Pole
Fiber
COAXIAL CABLES
Telco cable
Fiber
Fiber
Fiber
CAT 6
RG59
Patc
h p
an
el
Existing RS232
Distributor
RS232
Distributor
RG59
CAT 6
6
AD Manchester
Distributor
10
6
Cable Provider
Modem/Router
Communications
Provider
Network
Communications
Provider
Network
Communications
Provider
Network
HUT
US 1 NB @I-295
Existing C-Core
Video MUX
Ex
isti
ng
Patc
h P
an
el
#2
Existing
TCCOMM
RS232 distributor
video data
Port 46RJ6 TCCOMM
#4 - Tx
#6 - Gnd
Orange/White - Tx
Green - Gnd
Fiber
Communications
Provider
Network
Internet
TWP (Orange, Orange/White
TWP (Blue, Blue/White)
Existing Video
Switching System
(AD)
Existing rack space
NJDOT
NETWORK
Existing
W/S
Existing
Nextiva
Encoders
Existing
T1 MUX
Existing
C-Core MUX
COAXIAL CABLES
MPEG 4
encoder
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
See Cabinet Wiring Diagram for
more details
MPEG 4
encoder
PDU / Surge
Protection
MPEG 4
encoder
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
See Cabinet Wiring Diagram for
more details
MPEG 4
encoder
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
AD232-PELCO
TRANSLATOR AD232-PELCO
TRANSLATOR
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
AD232-PELCO
TRANSLATOR
PDU / Surge
Protection
See Cabinet Wiring Diagram for
more details
POLE No. POLE No. POLE No.
POLE No.
SURGE
PROTECTORS
SURGE
PROTECTORS
SURGE
PROTECTORS
SURGE
PROTECTORS
SURGE
PROTECTORS
SURGE
PROTECTORS
SURGE
PROTECTORS
CABLE MODEM
ET
HE
RN
ET
SW
ITC
H
ETHERNET
SWITCH
TERM SERVER
NODE -1 NODE -2
NODE -6
NODE -3
NODE -4
NODE -5
NODE -7
SWITCH
RT. 37, MP 2.57 @ NORTHAMPTON DR.
NODE -8
SWITCHSWITCH
M
RT. 37, MP 5.12 @ OAK RIDGE PKW
NODE -9
MEDIA CONVERTER
MEDIA CONVERTER
MEDIA CONVERTER
ETHERNET SWITCH
RT.37 @ CLIFTON AVE.
NODE-10
NODE-11
Coaxial Cable
CAT6
CAT6
CAT6
CAT6
CAT6
CAT6
CAT6
CAT6
55’ Pole
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
ItemNo Manufacturer Part Number
CCTV-DOME 1 PELCO SPECTRA IV, SD-435-E1
CCTV-POSITIONAL2 PELCO ESPRIT, ES30-CDW-24-5N
VIDEO ENCODER3 VERINT NEXTIVA, S1970E-T-XT
4
F/O VIDEO/DATA TRANSMITTER5 MERIDIAN ST-1W/1G-5M-ST
6
CCTV REMOTE DATA PORT7 PELCO RDPE-2
AD232-PELCO CODE TRANSLATOR8 SENNETECH SCT100-AD232-PELCO
9
10 CISCO WS-C3560-24T-S-SS
VIDEO DECODER VERINT NEXTIVA, S1970E-R
F/O VIDEO/DATA RECEIVER MERIDIAN SR-1W/1G-5M-ST
AD MANCHESTER-PELCO CODE
TRANSLATORSENNETECH SCT1019
11AD MANCHESTER CODE
DISTRIBUTORAMERICAN DYNAMICS AD2091
12F/O PATCH PANEL, CCTV
CONTROLLERL-COM FCM-2
13F/O PATCH PANEL, TRAFFIC
CONTROLLER -RT37FIS F1105818BLK
14120VAC MAIN LINE SURGE
SUPPRESSORATLANTIC SCIENTIFIC 22035
15 24VAC SURGE SUPPRESSOR ATLANTIC SCIENTIFIC 24580
16 RS422/485 SURGE SUPPRESSOR ATLANTIC SCIENTIFIC 24528
17 ATLANTIC SCIENTIFIC 24584
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
SAMPLE EQUIPMENT LIST
10/100/1000
24 PORT ETHERNET SWITCH
COAXIAL VIDEO SURGE SUPPRESSOR
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
TEL- Telephone Number
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
SAMPLE WIRING-DIAGRAM NOTES :
1 All connections are via AWG #14 solid copper
wire unless otherwise noted.
2. Blue wire is used for 24VAC connections.
3. All CCTV camera interface surge suppressors
are grounded via DIN rail.
4. All device ground connections are made to ground
bar.
5. Fan and Heater thermostat are adjustable type
6. Door switch is N.O. type - closes when the cabinet
door is opened.
CCTV CABINET WIRING DIAGRAM
(LEASED COMMUNICATIONS)
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
RJ45 RJ45
TB TBTB
BNCBNCRG59RG59
BNC
VERINT
S1970E-T-XT
ISP INTERFACE
(DSL/FIOS)
PELCO
RDPE-2
AUX
CONTROL
CAMERA SURGE
SUPPRESSORS
ATLANTIC
SCIENTIFIC
22035
GROUND TERMINAL
NEUTRAL
TERMINALS
115VAC POWER
MAIN TB
24VAC
100 VA
CCTV
POWER
SUPPLY
MAIN
BREAKER
FAN
LIGHT
Outlet #1
Outlet #2
FUSE,
5A
TERMINALS
To Surge
Suppressor To Encoder
RX+
RX-
RX+
RX-
TX+
TX-
1
2
1
2
Orange
Orange/white
Orange
Orange/white
Orange
Orange/white
Orange
Orange/white
OUT
IN
RJ45
REMOTE DATA
PORTVIDEO ENCODER
POWER
SUPPLY
ASSY.
POWER SUPPLY ASSY.
MAIN AC
SURGE
SUPPRESSOR
FEED
THRU
TB
100 CFM
CB 1 CB 2 CB 3 CB 4 CB 5
AC
G
N
Duplex
OutletAC
G
N
15A 15A 15A 15A 15A
Duplex
OutletAC
G
N
Heater Thermostat (NC)
12
Fan Thermostat (NO)
12
50A
NC1
400W
HEATER
LINE
NEUTRAL
GROUND
LINE
NEUTRAL
GROUND
CAT5E
Telephone Outlet
(DSL only)
ATLANTIC SCIENTIFIC
24584
ATLANTIC SCIENTIFIC24528
ATLANTIC SCIENTIFIC
24580
AWG #16
CAT6
AWG #12
GFCIGFCI
Outlet
BT #
CAT6
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
ItemNo Manufacturer Part Number
CCTV-DOME 1 PELCO SPECTRA IV, SD-435-E1
CCTV-POSITIONAL2 PELCO ESPRIT, ES30-CDW-24-5N
VIDEO ENCODER3 VERINT NEXTIVA, S1970E-T-XT
4
F/O VIDEO/DATA TRANSMITTER5 MERIDIAN ST-1W/1G-5M-ST
6
CCTV REMOTE DATA PORT7 PELCO RDPE-2
AD232-PELCO CODE TRANSLATOR8 SENNETECH SCT100-AD232-PELCO
9
10 CISCO WS-C3560-24T-S-SS
VIDEO DECODER VERINT NEXTIVA, S1970E-R
F/O VIDEO/DATA RECEIVER MERIDIAN SR-1W/1G-5M-ST
AD MANCHESTER-PELCO CODE
TRANSLATORSENNETECH SCT1019
11AD MANCHESTER CODE
DISTRIBUTORAMERICAN DYNAMICS AD2091
12F/O PATCH PANEL, CCTV
CONTROLLERL-COM FCM-2
13F/O PATCH PANEL, TRAFFIC
CONTROLLER -RT37FIS F1105818BLK
14120VAC MAIN LINE SURGE
SUPPRESSORATLANTIC SCIENTIFIC 22035
15 24VAC SURGE SUPPRESSOR ATLANTIC SCIENTIFIC 24580
16 RS422/485 SURGE SUPPRESSOR ATLANTIC SCIENTIFIC 24528
17 ATLANTIC SCIENTIFIC 24584
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
SAMPLE EQUIPMENT LIST
10/100/1000
24 PORT ETHERNET SWITCH
COAXIAL VIDEO SURGE SUPPRESSOR
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
TEL- Telephone Number
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
SAMPLE WIRING-DIAGRAM NOTES :
1 All connections are via AWG #14 solid copper
wire unless otherwise noted.
2. Blue wire is used for 24VAC connections.
3. All CCTV camera interface surge suppressors
are grounded via DIN rail.
4. All device ground connections are made to ground
bar.
5. Fan and Heater thermostat are adjustable type
6. Door switch is N.O. type - closes when the cabinet
door is opened.
CCTV CABINET WIRING DIAGRAM
(FIBER COMMUNICATION)
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
BNC
Orange
Orange/whiteTBTB
CODE TRANSLATOR
SCT-100+
-
RX
COM
VIDEO
F/O MODEM
DATA
TX
COM
ST
MERIDIAN
ST-1W/1G-5M-ST
L-COM
FCM-2
BNCRG59
RG59BNC
PELCO
RDPE-2
AUX
CONTROL
CAMERA SURGE
SUPPRESSORS
ATLANTIC
SCIENTIFIC
22035
GROUND TERMINAL
NEUTRAL
TERMINALS
115VAC POWER
MAIN TB
24VAC
100 VA
CCTV
POWER
SUPPLY
MAIN
BREAKER
FAN
LIGHT
Outlet #1
Outlet #2
FUSE,
5A
TERMINALS
To Surge
Suppressor To Encoder
RX+
RX-
TX+
TX-
1
2
Orange
Orange/white
Orange
Orange/white
Orange
Orange/white
Orange
Orange/white
OUT
IN
RJ45
REMOTE DATA
PORT
MAIN AC
SURGE
SUPPRESSOR
FEED
THRU
TB
100 CFM
CB 1 CB 2 CB 3 CB 4 CB 5
AC
G
N
Duplex
OutletAC
G
N
15A 15A
Duplex
Outlet
Heater Thermostat (NC)
12
Fan Thermostat (NO)
12
50A
NC1
400W
HEATER
LINE
NEUTRAL
GROUND
LINE
NEUTRAL
GROUND
POWER SUPPLY ASSY.
POWER SUPPLY ASSY.
1
2
AC
G
N
15A 15A 15A
PATCH PANEL
15A
CB 6TO GFCI RECEPTACLE
LOCATED IN CCTV POLE
ATLANTIC SCIENTIFIC
24584
ATLANTIC SCIENTIFIC
24528
ATLANTIC SCIENTIFIC
24580
AWG #16
CAT6 CAT6
CAT6
GFCI
Outlet
GFCI
AWG #12
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
DMS COMMUNICATION NETWORK
ASSIGNMENT TABLE
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
TEL- Telephone Number
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
DMS SYSTEM BLOCK DIAGRAM
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
DMSDMSDMSDMSDMSDMSDMSDMSDMSDMSDMSDMS
ITS-1
I-80 EB, MP 26.2 @ RT. 46ITS-2
I-80 WB, MP. 12.97 @ CR 519
ITS-10
I-195 EB, MP. 12.82 @ Rues RD
ITS-9
I-195 WB, MP 17.66 @ TRENTON -CASSVILLE
RD
ITS-12
I-195 WB, MP 10.25 @ SHARON STATION RD
DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
P Cabinet DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
P Cabinet DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
P Cabinet DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
P Cabinet DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
P Cabinet DMS
CONTROLLER
UPS
SURGE
PROTECTORS
PDU
EXISTING
MIST IV
SYSTEM
EXISTING
VANGUARD
SYSTEM
Communications Provider Network
TOC- NORTH
EXISTING
INTERFACE
EQUIPMENT
EXISTING
INTERFACE
EQUIPMENT
EXISTING
CONNECTION
EXISTING
CONNECTION
EXISTING
ON-TIME
SYSTEM
EXISTING
VANGUARD
SYSTEM
EXISTING
INTERFACE
EQUIPMENT
EXISTING
INTERFACE
EQUIPMENT
TOC- SOUTH
CAT6
Wire
less
Com
munic
atio
n
Connectio
n
TERMINAL
SERVER
MODEM
SWITCH
TERMINAL
SERVER
MODEM
SWITCH
NODE - 12
CAT6
Wire
less
Com
munic
atio
n
Connectio
n
NODE - 13NODE - 18
Communication
Connection
CAT6 CAT6 CAT6 CAT6TERMINAL
SERVER
SWITCH
TERMINAL
SERVER
SWITCH
TERMINAL
SERVER
SWITCH
TERMINAL
SERVER
SWITCH
NODE - 14 NODE - 15
ITS-11
I-195 WB, MP 15.85 @ RICHARDSON RD.
NODE - 16 NODE - 17
SWITCH
CAT6
CA
T6
NODE - 11
FIBER FIBER FIBER
FIB
ER
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
FIBER ASSIGNMENT DIAGRAM
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
RED
BLACK
BU
ND
LE
FIB
ER
WIM CONTROLLER
DMS CONTROLLER
CCTV RECEIVER / DRIVER
CONTROL VIDEO
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
BLUE
GREEN
BROWN
SLATE
WHITE
PATCHLOOP
PATCHLOOP
PATCHLOOP
RG-59U
12 PORT PATCH PANEL
SC CONNECTORS
RJ-45
8 PORT ETHERNET SWITCH
SINGLE CHANNEL
MPEG 4 VIDEO
ENCODER
8 PORT ETHERNET SWITCH
DMS CONTROLLER
CCTV RECEIVER / DRIVER
CONTROL VIDEO
RJ-45
RJ-45
RG-59U
SINGLE CHANNEL
MPEG 4 VIDEO
ENCODER
8 PORT ETHERNET SWITCH
8 PORT ETHERNET SWITCH
CCTV RECEIVER / DRIVER
CONTROL VIDEO
RJ-45
RJ-45
RG-59U
SINGLE CHANNEL
MPEG 4 VIDEO
ENCODER
8 PORT ETHERNET SWITCH
PATCHLOOP
TERMINATE TRUNK CABLE (FIBER OPTIC CABLE TYPE A)
IN THE SPLICE ENCLOSURE
RJ-45
TTS CONTROLLER
PATCHLOOP
RJ-45
CAT 5
24- PORT ETHERNET SWITCH
48
- P
OR
T E
TH
ER
NE
T P
AT
CH
PA
NE
L
CISCO 3750 SWITCH
CWDM INTERFACE SWITCH
RJ-45
8 PORT ETHERNET
SWITCH
10
0 B
AS
E F
X
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
FIBER OPTIC
CABLE
TYPE D
8 PORT ETHERNET SWITCH
BLUE
ORANGE
WHITE
10
0 B
AS
E T
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E T
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
10
0 B
AS
E F
X
100 BASE FX
12 PORT PATCH PANEL
SC CONNECTORS
12 PORT PATCH PANEL
SC CONNECTORS
12 PORT PATCH PANEL
SC CONNECTORS
12 PORT PATCH PANEL
SC CONNECTORS
12 PORT PATCH PANEL
SC CONNECTORS
12 PORT PATCH PANEL
SC CONNECTORS
PATCHLOOP
ItemNo Manufacturer Part Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
SAMPLE EQUIPMENT LIST
DEVICE TYPE
NODE No.
RT. XXX
M.P.
DEVICE TYPE
NODE No.
RT. XXX
M.P.
DEVICE TYPE
NODE No.
RT. XXX
M.P.
DEVICE TYPE
NODE No.
RT. XXX
M.P.
DEVICE TYPE
NODE No.
RT. XXX
M.P.
DEVICE TYPE
NODE No.
RT. XXX
M.P.DEVICE TYPE
NODE No.
RT. XXX
M.P.
JB M.P. XXX JB M.P. XXX JB M.P. XXX JB M.P. XXX JB M.P. XXX JB M.P. XXX
COMMUNICATION HUB No. XXX
ROUTE XXX M.P. XXXX
CAT6
CAT6
CAT6
CAT6
CAT6
CAT6
CAT6
PROJECT TITLE
SAMPLE ITS WORKING DRAWINGS
Legend
Proposed Equipment
Proposed Connection
Communications Provider Network
Existing Connection
N
N = Number of cables in
bundle
Existing Equipment
BT466JK
Communications Services
Pole and Pole ID
ABBREVIATIONS
DMS- Dynamic Message Sign
UPS- Uninterruptible Power Supply
PDU- Power Distribution Unit
TEL- Telephone Number
P/P- Patch Panel
UTP- Unshielded Twisted Pair
STP- Shielded Twisted Pair
F/O- Fiber Optics
ISP- Internet Services Provider
W/S- PC workstation
DESIGNER
RECOMMENDATION
FOR APPROVAL
CONTRACTOR APRVL
STAMP & SIGNATURE
NJDOT APPROVAL
SAMPLE BLOCK-DIAGRAM NOTES :
1. Block diagram presents a proposed system solution.
See cabinet wiring diagrams for details.
2. CCTV Composite cable consists of RG59, two shielded
twisted pairs, power conductors
3. Only one "Blue-White" pair is used for telephone connection.
All the others are not connected.
4. Indicated camera addresses correspond to video switcher
ports at TOC-N and TOC-S
5. Each DMS, CCTV and DMS controller cabinet is powered by
120VAC provided by local power unitlity
6. Existing AD Video Switching System as shown includes switching
and expansion chassis, CPU, Code converters,keyboards and
interconnecting cables.
7. Provide rack layout diagram.
TOC BLOCK DIAGRAM
XXX REGION
CONTRACTOR NAME
CONTRACT NO. XXXXXXX
FEDERAL PROJECT NO. XXXXXXXXXX
RG59 CABLES (VIDEO)
24 PORT 10/100
Ethernet Switch
Nextiva system6 Video Decoders
AD-Pelco translator
1 2 3 4 5 6
DATA VIDEO
COAXIAL CABLES
Telco cable
6
AD Manchester
Distributor
10
6
Cable Provider
Modem/RouterInternet
TWP (Orange, Orange/White
TWP (Blue, Blue/White)
Existing Video
Switching System
(AD)
NJDOT
NETWORK
Existing
W/S
Existing
Nextiva
Encoders
Existing
T1 MUX
Existing
C-Core MUX
COAXIAL CABLES
NODE-11
CAT6
CAT6
CAT6
CAT6
TOC
ItemNo Manufacturer Part Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
SAMPLE EQUIPMENT LIST
Existing rack space* See Note 7