sales training update laura gonzalez roc800 mmi (13ras023)

18
Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

Upload: rhoda-holland

Post on 17-Jan-2016

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

Sales Training Update

Laura Gonzalez

ROC800 MMI(13RAS023)

Page 2: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 2

Coriolis Interface Module-Agenda• Coriolis Interface Module• Features and Benefits• The Coriolis Interface Solution• Typical Applications• Installation and Setup • Compatibility• Conclusion

Page 3: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 3

Coriolis Interface Module

• Communicates directly with the core processor of Emerson Coriolis meters (with an Intrinsically Safe barrier) and transmitters

• Automatically retrieves data for monitoring and control of – Key Operating Data– Calibration Information– Diagnostics Information– Can calculate flow based on MODBUS data no pulse transmitter

required

• Communicates with up to six Coriolis Meters in the ROC800 (up to four in the FB107)

Page 4: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 4

Features and Benefits

• Enables on line calibration using ROCLINK800• Enables diagnostics with quick access to Coriolis data• With ROCLINK800 - control and monitor features such as:

– Meter Zeroing– Smart Meter Verification (SMV)– Transient Bubble Remediation (TBR)– Transient Mist Remediation (TMR) *new*

– Production Volume Reconciliation (PVR) *new* - Net oil calculations

Page 5: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 5

The Coriolis Interface Solution

• Keep the pulse transmitter - Meet API Chapter 11 • Replace transmitter with IS barrier - Increase value to customer

- Easier to maintain (only one config tool)- Reduce total cost of ownership- Make Allocation measurements

Coriolis Interface Module

Intrinsically Safe Barrier

Page 6: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 6

Typical Applications

• Monitor well head separator performance • Monitor two phase separators with Gas and Liquid flow and percent water (Net Oil) calculations

• Monitor three phase separators with Gas, Oil and Water outputs.

• Measure flow from tanks and LACT skids for truck loading and unloading

Page 7: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 7

Installation and Setup

• The Application Guide Part D301753X012 describes the installation and set up procedure for the ROC800L and the FB107

• This is similar to the Guide used in the training for the FB107

• The new areas are– Adding of TMR and PVR to the Module– A modification to the setup for ROC800L Liquid Calcs– A modification for the setup for the gas meter in the

ROC800L

Page 8: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 8

Adding TMR and PVR

• The following display shows the addition of a panel that defines the available options in the core processor

– PVR– SMV– TBR– TMR

This defines the options that are available in the Coriolis Meter being configured.

The calibration display, the diagnostics display and smart meter verification display did not change

Page 9: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 9

Coriolis Module Setup Display

Page 10: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 10

TBR and TMR

• Transient Bubble Remediation (TBR)– used to handle occasional gas bubbles or slugs of air in the

process fluid.

• Transient Mist Remediation (TMR) *new with this release*

– used to handle occasional gas mist (water or oil) appearances in gas flow

Page 11: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 11

TBR Display

Page 12: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 12

TMR Display

Page 13: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 13

The PVR Function

• The PVR feature adds the ability to calculate the % water content in the Liquid being measured.

• The data inputs required are:– The reference temperature– The Oil Base Density – The Water Base density

• The Core processor then calculates the water cut, the various flow rates and flow totals.

• This data is retrieved by the Coriolis Interface Module and is available for use in the Gas measurement and Liquid Measurement calculations

Page 14: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 14

The PVR Display

Page 15: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 15

Compatibility

Version 1.10 of the Coriolis Interface module is compatible with the following:

– ROC800 v3.61– ROC800L v1.41– ROC800L Liquid Calcs User Program v1.04.00– FB107 v1.70– FB107 Liquid Allocation Mgmt User Program v1.00– ROCLink800 v2.41– Micro Motion Coriolis meter models 700 (v3.2 or later) and 800 (v3.9 or

later)– Micro Motion Transmitter models 1500, 1700, 2500, 2700 and 3700

Page 16: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 16

FAQs• Does the module write down to the core processor?

– No, it does not.

• Can the APM for ROC800 be used instead of the transmitter?

– No it cannot.– For custody, a pulse for liquid is required but for gas MODBUS flow rates

can be used to do the gas calculation.

• Can we meet the AGA 1 second update standard? – A four meter run will meet 1 second updates for AGA but the 6

meter run will not as it takes about 2 Seconds to update the 6 meters.

• Can the MODBUS registers be changed in the module? – The MODBUS registers used in the CIM are fixed and cannot be

changed.

Page 17: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 17

Conclusion: Measurement Challenges - Met Challenge Solution

Integration of Coriolis meters with Emerson flow computers is

complicated, and our competitors make it easy

Coriolis Interface Module automatically links the MMI

Coriolis with FB107 and ROC800

Customers may not know how effective their production systems

are – How many dump cycles? How much accumulation of what?

Better monitoring of the separation and dump cycle

process. (Beta test unit counted 2,000 + dump cycles in a day)

Remote solar powered installations require reduced

power.

Eliminate the need for transmitters for reduced system power requirements (Allocation

applications).

Page 18: Sales Training Update Laura Gonzalez ROC800 MMI (13RAS023)

CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 18

Questions?

• If you have any questions, please feel free to contact me at [email protected].