10TD Temp / Humidity המכון לבקרה ואיכותControllers Ltd R sk PSK Controllers Ltd. C e r tifie d Q u ality M a n a g e m e n t S y s t e m Istitute of Quatity & Control Temp C Humidity Temp / Humidity MOD-10TD HTD The MOD-10TD-HTD- LXX inch is designed to be usedin an industrial or public environment where a large highly visible display is needed. All of the digits are equal in total height and displays accurately and intelligibly from 40m upto 160m away. The MOD-10TD-HTD - LXX can be used ina wide variety of applications with no additional equipment. It can be displayed on a wall or a top ceiling. It comes standard with 240V 50-60 Hz. General description Temperature / Humidity Number of segments: 4 or 6 Coating: Co: Coated Nil: Regular Sealed: Se: Sealed IP67 Nil: Flux proof Type: RTD: PT100 Segment height: 2.3”, 4”, 5”, 7” Operation Voltage: 240, 110, 24VAC 50/60Hz. Visible 40-160m Aluminum case 1 year warranty Super Bright Led Display Back panel Control Display Time 24h Wired Control RS 232 Control Displays Time and day Displays Time, Humidity and Temperature IP68 Sealing Wide input voltage Range Features Temp C Humidity D T INSTALLATION ENVIRONMENT: The unit should be installed in a location that does not exceed the operating temperature. Placing the unit near devices that generate excessive heat should be avoided. The unit should only be cleaned with a soft cloth and neutral soap product. Do NOT use solvents.Continuous exposure to direct sunlight may the front overlay. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) accelerate the aging process of to operate the keypad of the unit. MOUNTING INSTRUCTIONS: This display is designed to be wall mounted or suspended from a ceiling truss or other suitable structure capable of supporting the MOD-10TD HTD. Caution should be exercised when hanging the display to provide for the safety of personnel. If hanging the 10TD HTD, run the suspension cables (or chains) through the mounting bracket holes. Installation Safety summary All safety regulations, local codes and instructions that appearin this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer,the protection provided by the equipment may be impaired. The protective conductor terminal is bonded to condtive parts of the equipment for safety purposes and must be connected to an external protective earthing system. CAUTION: Risk of electric shock. CAUTION: Risk of Danger Read complete instructions prior to installation and operation of the unit. General specifications Led Display: 7 segment; red LED display (refer to table bellow). Display: temperature, humidity. Power source: work with wide voltage Ranges. Measurement Humidity: 0~100% RH Measurement Temp: 0~100 C, (-20 ~+80 C). Accuracy (At 25 C): + 2% RH, +0.3 C. Long-term Stability: Better than 1% RH per year (Typical). Temp. Compensation: + 0.008%RH/ C (Effect @ 0% RH). Operating Temp:-10 to 49 C (32 to 120 Fahrenheit). Case: Aluminum black powder coated casing with red acrylic front glass. Case dimensions: refer to case dimensions table (1). Visible: 40-160m (Related to segment size). Sealing proof: IP42 O O O O O O O O O * * * * * * *

Upload: halien

Post on 15-Mar-2018

215 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Safety summary 10TD Temp / Humidity - psk.ccpsk.cc/wp-content/uploads/2016/12/MOD-10TD_HTD_new_eng.pdfQuatity & Control y T em p C H um idit ... generate excessive heat should be avoided

10T

D T

emp

/ Hum

idity

המכון לבקרה ואיכות

Controllers Ltd

R

sk

PSK Controllers Ltd.C

ertified Quality Management Sy

stem

Istitute of Quatity & Control

Temp C

Humidity

Temp / HumidityMOD-10TD HTD

The MOD-10TD-HTD- LXX inch is designed to be usedin anindustrial or public environment where a large highly visibledisplay is needed. All of the digits are equal in total height and displays accurately and intelligibly from 40m upto 160m away. The MOD-10TD-HTD - LXX can be used ina wide variety of applications with no additional equipment. It can be displayed on a wall or a top ceiling. It comes standard with 240V 50-60 Hz.

General description

Temperature / HumidityNumber of segments: 4 or 6 Coating: Co: Coated Nil: Regular Sealed: Se: Sealed IP67 Nil: Flux proofType: RTD: PT100Segment height: 2.3”, 4”, 5”, 7”Operation Voltage: 240, 110, 24VAC 50/60Hz.

Visible 40-160mAluminum case1 year warrantySuper Bright Led DisplayBack panel ControlDisplay Time 24hWired ControlRS 232 Control Displays Time and dayDisplays Time, Humidity and Temperature IP68 SealingWide input voltage Range

Features

Temp C

Humidity

H

D

T

INSTALLATION ENVIRONMENT:The unit should be installed in a location that does not exceed the operating temperature. Placing the unit near devices that generate excessive heat should be avoided. The unit should only be cleaned with a soft cloth and neutral soap product. Do NOT use solvents.Continuous exposure to direct sunlight may the front overlay. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) accelerate the aging process of to operate the keypad of the unit.

MOUNTING INSTRUCTIONS:This display is designed to be wall mounted orsuspended from a ceilingtruss or other suitablestructure capable ofsupporting the MOD-10TDHTD. Caution should beexercised when hangingthe display to provide forthe safety of personnel. Ifhanging the 10TD HTD, run thesuspension cables (or chains)through the mounting bracketholes.

Installation

Safety summary

All safety regulations, local codes and instructions that appearin this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer,the protection provided by the equipment may be impaired.

The protective conductor terminal is bonded to condtive parts of the equipment for safety purposes and must be connected to an external protective earthing system.

CAUTION: Risk of electric shock.CAUTION: Risk of Danger

Read complete instructions prior toinstallation and operation of the unit.

General speci�cations

Led Display: 7 segment; red LED display (refer to table bellow). Display: temperature, humidity. Power source: work with wide voltage Ranges.Measurement Humidity: 0~100% RHMeasurement Temp: 0~100 C, (-20 ~+80 C).Accuracy (At 25 C): + 2% RH, +0.3 C.Long-term Stability: Better than 1% RH per year (Typical).Temp. Compensation: + 0.008%RH/ C (Effect @ 0% RH).Operating Temp:-10 to 49 C (32 to 120 Fahrenheit).Case: Aluminum black powder coated casing with redacrylic front glass. Case dimensions: refer to case dimensions table (1).Visible: 40-160m (Related to segment size).Sealing proof: IP42

O O O O

O O

O O

O

*

*

*

*

*

*

*

Page 2: Safety summary 10TD Temp / Humidity - psk.ccpsk.cc/wp-content/uploads/2016/12/MOD-10TD_HTD_new_eng.pdfQuatity & Control y T em p C H um idit ... generate excessive heat should be avoided

המכון לבקרה ואיכות

10T

D T

emp

/ Hum

idity

Controllers Ltd

R

sk

PSK Controllers Ltd.C

ertified Quality Management Sy

stem

Istitute of Quatity & Control

Display: Red led 4” seven segmentNumber of segments:6 digits display time3 digits- display temperature3 digits display humidityHousing: Epoxy paint coated aluminum White / BlackFixture: 2 metal backet 360Temperature / Humidity sensor fixed on the back panelUpdating options:3 fixed buttons on the back panel3 remote control button (refer to the picture below)

O

O360

140

100

DimensionsTechnical Data

Back Panel

Ordering information

MOD-10TD HTD

Co: 1 = Coted R = RegularSe: 1 = Sealed IP67 F= Flux ProofH : Segment digitV : Operating VoltageC : Box ColorL : Installation Location

Co - Se - H - V - C - L

R1

F1

4”5”7”

2.3” blackwhite

230VAC110VAC24VAC

indooroutdoor

VAC 230