safety for hydraulics cindy leak−free load control valves ... · safety for hydraulics...

84
Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04 1/84 430.90.72. Reference: Classification: Issue: 09.2015 1/84 Reference: 300-P-9050013-EN-02

Upload: others

Post on 10-Feb-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

Safety for Hydraulics�Cindy" Leak−Free Load Control Valves, Manifold Mounting Design

300−P−9050013−E−02/03.041/84 430.90.72.

Reference:Classification:Issue: 09.2015 1/84 Reference: 300-P-9050013-EN-02

Page 2: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 2/84

Contents Page

1. Selection table for type P, serie Cindy 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. Description Cindy−12−B−P.. − .... −A− ... − .. 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. Description Cindy−12−B−P.. − .... −L− ... − .. 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. Description Cindy−12−B−P.. − .... −A− ... − .. −SVA 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5. Description Cindy−12−B−P.. − .... −L− ... − .. −SVA 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6. Description Cindy−12−B−P.. − .... −L− ... − .. −SVT 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7. Description Cindy−16−B−P.. − .... −A− ... − .. 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8. Description Cindy−16−B−P.. − .... −L− ... − .. 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9. Description Cindy−16−B−P.. − .... −A− ... − .. −SVA... 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10. Description Cindy−16−B−P.. − .... −L− ... − .. −SVA... 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11. Description Cindy−16−B−P.. − .... −L− ... − .. −SVT... 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12. Description Cindy−20−B−P.. − .... −A− ... − .. 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13. Description Cindy−20−B−P.. − .... −L− ... − .. 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14. Description Cindy−20−B−P.. − .... −A− ... − .. −SVA... 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15. Description Cindy−20−B−P.. − .... −L− ... − .. −SVA... 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16. Description Cindy−20−B−P.. − .... −L− ... − .. −SVT... 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17. Description Cindy−25−B−P.. − .... −A− ... − .. 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18. Description Cindy−25−B−P.. − .... −L− ... − .. 68. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19. Description Cindy−25−B−P.. − .... −A− ... − .. −SVA... 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20. Description Cindy−25−B−P.. − .... −L− ... − .. −SVA... 76. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21. Description Cindy−25−B−P.. − .... −L− ... − .. −SVT... 80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Issue: 09.2015 2/84 Reference: 300-P-9050013-EN-02

Page 3: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 3/84

1. Selection table for type P, serie Cindy

X = standard catalogue valve

Flo

w r

ate

[l/m

in.]

InterfaceWith secondary pressure relief valve(see General Informa−tion Leaflet, section 10.)

Pilot pressuredepending ofback−pressure

Pilot pressure in−depending ofback−pressure

Catalogue datasheet / page nos.

X sect. 2., p. 4

P ]

X sect. 3., p. 8

y 12

-B-P

0 [

l/min

.]

Bucher standard in return line X sect. 4., p. 12

Cin

dy 1

to 1

50

in in return line X sect. 5., p. 16

in tank line X sect. 6. , p. 20

X sect. 7., p. 24

-P n.]

X sect. 8., p. 28

y 16

-B-P

50

[l/m

in.]

Bucher standard in return line X sect. 9., p. 32

Cin

dyto

25

0

in return line X sect. 10., p. 36

in tank line X sect. 11., p. 40

X sect. 12., p. 44

-P n.]

X sect. 13., p. 48

y 20

-B-P

50

[l/m

in.]

Bucher standard in return line X sectt. 14., p. 52

Cin

dyto

35

0

in return line X sect. 15., p. 56

in tank line X sect. 16., p. 60

X sect. 17., p. 64

-P n.]

X sect. 18., p. 68

y 25

-B-P

00

[l/m

in.]

Bucher standard in return line X sect. 19., p. 72

Cin

dyto

50

0

in return line X sect. 20., p. 76

in tank line X sect. 21., p. 80

Issue: 09.2015 3/84 Reference: 300-P-9050013-EN-02

Page 4: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 4/84

2. Description Cindy−12−B−P..−....−A−...−..

2.1 Port sizes / weight Port Port size O-Ring2.1 Port sizes / weight

A max. ø13 3.53x18.66

B max. ø13 3.53x18.66

X max. ø4 1.78x5.28

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 4.1 kg

2.2 Standard model

33.5

A B

65

131.5

M8

36

.5

60

24

16

A B

X

584

6

30

23

13

ø25.4

ø8.6

ø25.4 max.ø13

M8x13/17

74

0.01 / 100mm

2323

30

60

58

33

.5

13

1.5

10

7.5

max.ø13

max.ø4

X

A

B

Mounting surface

188.5

26

Rmax

10

X BA

Serial−No.

Nameplate

Issue: 09.2015 4/84 Reference: 300-P-9050013-EN-02

Page 5: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 5/84

2.3 Pilot−control variants (each can be rotated through 180°)

app. 22 453

0

50

BAX

BAX

63

.5

36

.5

16.5 45

30

50

63

.5

36

.5

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

A/F 6

A/F 22

A/F 22

A/F 6

Issue: 09.2015 5/84 Reference: 300-P-9050013-EN-02

Page 6: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 6/84

2.4 Characteristic curves (measured at 33 mm2/s [cSt])

2.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

2.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 6/84 Reference: 300-P-9050013-EN-02

Page 7: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 7/84

2.5 Model code key

S020 =

S045 =

S060 =

S100 =

S140 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 12 B- - AP - -

12 mm

Nominal size

= 12

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S020

S045

S060

S100

S140

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010628..... 300 6010633..... 300 6010638.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 12−B−P−N−1−G300.0306941

Service packages Cindy 12−B−P−V−1−G300.0306947

Service packages Cindy 12−B−P−T−1−G300.0306953

Pilot−control types D, H

Art. No.

Service packages Cindy 12−B−P−N−1−D300.0306942

Service packages Cindy 12−B−P−V−1−D300.0306948

Service packages Cindy 12−B−P−T−1−D300.0306954

Issue: 09.2015 7/84 Reference: 300-P-9050013-EN-02

Page 8: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 8/84

3. Description Cindy−12−B−P..−....−L−...−..

3.1 Port sizes / weight Port Port size O-Ring3.1 Port sizes / weight

A max. ø13 3.53x18.66

B max. ø13 3.53x18.66

X, L max. ø4 1.78x5.28

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 4.1 kg

3.2 Standard model

33.5

70

A B

65

131.5

M8

36

.5

60

26

24

16

A BL

X

584

6

30

23

13

ø8.6

ø8.6

ø25.4

ø25.4

max.ø13

M8x13/17

74

13

2323

30

60

70 5

8

33

.5

13

1.5

10

7.5

max.ø13

max.ø4

max.ø4

X

L

A

B

Mounting surface

13

188.5

0.01 / 100mm

Rmax

10

X BAL

Serial−No.

Nameplate

Issue: 09.2015 8/84 Reference: 300-P-9050013-EN-02

Page 9: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 9/84

3.3 Pilot−control variants (each can be rotated through 180°)

app. 22 453

0

50

BAX

BAX

63

.5

36

.5

16.5 45

30

50

63

.5

36

.5

A/F 6

A/F 22

A/F 22

A/F 6

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 9/84 Reference: 300-P-9050013-EN-02

Page 10: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 10/84

3.4 Characteristic curves (measured at 33 mm2/s [cSt])

3.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

3.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 10/84 Reference: 300-P-9050013-EN-02

Page 11: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 11/84

3.5 Model code key

S020 =

S045 =

S060 =

S100 =

S140 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 12 B- - LP - -

12 mm

Nominal size

= 12

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S020

S045

S060

S100

S140

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010629..... 300 6010634..... 300 6010639.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 12−B−P−N−1−G300.0306941

Service packages Cindy 12−B−P−V−1−G300.0306947

Service packages Cindy 12−B−P−T−1−G300.0306953

Pilot−control types D, H

Art. No.

Service packages Cindy 12−B−P−N−1−D300.0306942

Service packages Cindy 12−B−P−V−1−D300.0306948

Service packages Cindy 12−B−P−T−1−D300.0306954

Issue: 09.2015 11/84 Reference: 300-P-9050013-EN-02

Page 12: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 12/84

4. Description Cindy−12−B−P..−....−A−...−..−SVA

4.1 Port sizes / weight Port Port size O-Ring4.1 Port sizes / weight

A max. ø13 3.53x18.66

B max. ø13 3.53x18.66

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.2 kg

4.2 Standard model

33.5

A B

MB

65

131.5

M8

36

.5

95

24

24

16

A B

X

587

1

30

23

13

ø8.6

ø25.4

ø25.4

max.ø13

M8x13/17

74

2323

30

95

58

33

.5

13

1.5

10

7.5

max.ø13

max.ø4

X

A

B

Mounting surface

46

188.5

26

5

104.5

0.01 / 100mm

Rmax

10

Serien−Nr.

Typenschild

X B

MB

A

Serial−No.

Nameplate

Issue: 09.2015 12/84 Reference: 300-P-9050013-EN-02

Page 13: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 13/84

4.3 Pilot−control variants (each can be rotated through 180°)

app. 22 45

65

50

BAX

BAX

63

.5

36

.5

16.5 45

30

50

63

.5

36

.5

A/F 6

A/F 22

A/F 22

A/F 6

MB

MB

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 13/84 Reference: 300-P-9050013-EN-02

Page 14: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 14/84

4.4 Characteristic curves (measured at 33 mm2/s [cSt])

4.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

4.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

4.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 14/84 Reference: 300-P-9050013-EN-02

Page 15: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 15/84

4.5 Model code key

S020 =

S045 =

S060 =

S100 =

S140 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 12 B- - AP - -

12 mm

Nominal size

= 12

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S020

S045

S060

S100

S140

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010630..... 300 6010635..... 300 6010640.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 12−B−P−N−2−G300.0306943

Service packages Cindy 12−B−P−V−2−G300.0306949

Service packages Cindy 12−B−P−T−2−G300.0306955

Pilot−control types D, H

Art. No.

Service packages Cindy 12−B−P−N−2−D300.0306944

Service packages Cindy 12−B−P−V−2−D300.0306950

Service packages Cindy 12−B−P−T−2−D300.0306956

Issue: 09.2015 15/84 Reference: 300-P-9050013-EN-02

Page 16: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 16/84

5. Description Cindy−12−B−P..−....−L−...−..−SVA

5.1 Port sizes / weight Port Port size O-Ring5.1 Port sizes / weight

A max. ø13 3.53x18.66

B max. ø13 3.53x18.66

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.2 kg

5.2 Standard model

33.5

70

A B

MB

65

131.5

M8

36

.5

95

24

24

16

A B

X

58

71

30

23

13

ø8.6

ø8.6

ø25.4

ø25.4

max.ø13

M8x13/17

74

13

2323

30

95

70 5

8

33

.5

13

1.5

10

7.5

max.ø13

max.ø4

X

L

A

B

Mounting surface

46

188.5

26

5

104.5

13 L

max.ø4

0.01 / 100mm

Rmax

10

Serial−No.

Nameplate

X B

MB

AL

Issue: 09.2015 16/84 Reference: 300-P-9050013-EN-02

Page 17: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 17/84

5.3 Pilot−control variants (each can be rotated through 180°)

app. 22 456

5

50

BAX

BAX

63

.5

36

.5

16.5 45

30

50

63

.5

36

.5

A/F 6

A/F 22

A/F 22

A/F 6

L

MB

L

MB

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 17/84 Reference: 300-P-9050013-EN-02

Page 18: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 18/84

5.4 Characteristic curves (measured at 33 mm2/s [cSt])

5.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

5.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

5.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 18/84 Reference: 300-P-9050013-EN-02

Page 19: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 19/84

5.5 Model code key

S020 =

S045 =

S060 =

S100 =

S140 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 12 B- - LP - -

12 mm

Nominal size

= 12

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S020

S045

S060

S100

S140

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010631..... 300 6010636..... 300 6010641.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 12−B−P−N−2−G300.0306943

Service packages Cindy 12−B−P−V−2−G300.0306949

Service packages Cindy 12−B−P−T−2−G300.0306955

Pilot−control types D, H

Art. No.

Service packages Cindy 12−B−P−N−2−D300.0306944

Service packages Cindy 12−B−P−V−2−D300.0306950

Service packages Cindy 12−B−P−T−2−D300.0306956

Issue: 09.2015 19/84 Reference: 300-P-9050013-EN-02

Page 20: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 20/84

6. Description Cindy−12−B−P..−....−L−...−..−SVT

6.1 Port sizes / weight Port Port size O-Ring6.1 Port sizes / weight

A max. ø13 3.53x18.66

B max. ø13 3.53x18.66

T max. ø13 3.53x18.66

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.2 kg

6.2 Standard model

33.5

40

A B

MB

65

131.5

M8

36

.5

95

24

24

16

A B

T

X

58

71

30

2823

13

ø8.6

ø25.4

ø25.4

ø25.4

max.ø13

M8x13/17

74

28

2323

30

95

58

40 33

.5

13

1.5

10

7.5

max.ø13

max.ø4

max.ø13X

TA

B

Mounting surface

46

188.5

26

5

104.5

0.01 / 100mm

Rmax

10

X B

MB

T

Serial−No.

Nameplate

A

Issue: 09.2015 20/84 Reference: 300-P-9050013-EN-02

Page 21: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 21/84

6.3 Pilot−control variants (each can be rotated through 180°)

app. 22 45

65

50

BAX

63

.5

36

.5

16.5 45

30

50

63

.5

36

.5

A/F 6

A/F 22

A/F 22

A/F 6

T

MB

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

BAX T

MB

Issue: 09.2015 21/84 Reference: 300-P-9050013-EN-02

Page 22: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 22/84

6.4 Characteristic curves (measured at 33 mm2/s [cSt])

6.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

6.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150

Flow rate [l/min]

∆p [b

ar]

6.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 22/84 Reference: 300-P-9050013-EN-02

Page 23: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 23/84

6.5 Model code key

S020 =

S045 =

S060 =

S100 =

S140 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 12 B- - LP - -

12 mm

Nominal size

= 12

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S020

S045

S060

S100

S140

Flow rate when lowering (spool size)

SVT

80 to 460 bar

Pressure setting

... =

Pressure relief from B to T

(tank line required)

Secondary pressure relief

SVT =

-

Independent of back pressure in A

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010632..... 300 6010637..... 300 6010642.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 12−B−P−N−3−G300.0306945

Service packages Cindy 12−B−P−V−3−G300.0306951

Service packages Cindy 12−B−P−T−3−G300.0306957

Pilot−control types D, H

Art. No.

Service packages Cindy 12−B−P−N−3−D300.0306946

Service packages Cindy 12−B−P−V−3−D300.0306952

Service packages Cindy 12−B−P−T−3−D300.0306958

Issue: 09.2015 23/84 Reference: 300-P-9050013-EN-02

Page 24: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 24/84

7. Description Cindy−16−B−P..−....−A−...−..

7.1 Port sizes / weight Port Port Size O-Ring7.1 Port sizes / weight

A max. ø16 2.62x20.29

B max. ø16 2.62x20.29

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 5.0 kg

7.2 Standard model

38

83

A BX

MB 60 70

211

M10

28

75

33142

31.5

11.9

A B 37

.5

X

60

51

25

.51

5

ø25.3

ø25.3

ø8.6

M10x15/19

25.525.5

37.5

75

71

.9

60

38

11

0.5

83

max.ø16

max.ø16

max.ø4

X

A

B

Mounting surface

14

2

0.01 / 100mm

Rmax

10

X B

MB

Serial−No.

Nameplate

A

Issue: 09.2015 24/84 Reference: 300-P-9050013-EN-02

Page 25: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 25/84

7.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 25/84 Reference: 300-P-9050013-EN-02

Page 26: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 26/84

7.4 Characteristic curves (measured at 33 mm2/s [cSt])

7.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

7.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 26/84 Reference: 300-P-9050013-EN-02

Page 27: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 27/84

7.5 Model code key

S100 =

S150 =

S200 =

S240 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 16 B- - AP - -

16 mm

Nominal size

= 16

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010841..... 300 6010846..... 300 6010851.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 16−B−P−N−1−G300.0307132

Service packages Cindy 16−B−P−V−1−G300.0307138

Service packages Cindy 16−B−P−T−1−G300.0307144

Pilot−control types D, H

Art. No.

Service packages Cindy 16−B−P−N−1−D300.0307133

Service packages Cindy 16−B−P−V−1−D300.0307139

Service packages Cindy 16−B−P−T−1−D300.0307145

Issue: 09.2015 27/84 Reference: 300-P-9050013-EN-02

Page 28: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 28/84

8. Description Cindy−16−B−P..−....−L−...−..

8.1 Port sizes / weight Port Port size O-Ring8.1 Port sizes / weight

A max. ø16 2.62x20.29

B max. ø16 2.62x20.29

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 5.0 kg

8.2 Standard model

38

70

83

A BX

MB 60 7

0

211

M10

28

75

33

L

142

31.5

11.9

A B 37

.5

L

X

60

51

25

.51

5

ø25.3ø8.6

ø8.6

max.ø4

M10x15/19

25.525.5

37.5

75

71

.9

60

38

70

11

0.58

3

max.ø16

max.ø16

max.ø4

X

L

A

B

Mounting surface

14

2

ø25.3

0.01 / 100mm

Rmax

10

X B

MB

AL

Serial−No.

Nameplate

Issue: 09.2015 28/84 Reference: 300-P-9050013-EN-02

Page 29: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 29/84

8.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 29/84 Reference: 300-P-9050013-EN-02

Page 30: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 30/84

8.4 Characteristic curves (measured at 33 mm2/s [cSt])

8.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

8.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 30/84 Reference: 300-P-9050013-EN-02

Page 31: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 31/84

8.5 Model code key

S100 =

S150 =

S200 =

S240 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 16 B- - LP - -

16 mm

Nominal size

= 16

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010842..... 300 6010847..... 300 6010852.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 16−B−P−N−1−G300.0307132

Service packages Cindy 16−B−P−V−1−G300.0307138

Service packages Cindy 16−B−P−T−1−G300.0307144

Pilot−control types D, H

Art. No.

Service packages Cindy 16−B−P−N−1−D300.0307133

Service packages Cindy 16−B−P−V−1−D300.0307139

Service packages Cindy 16−B−P−T−1−D300.0307145

Issue: 09.2015 31/84 Reference: 300-P-9050013-EN-02

Page 32: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 32/84

9. Description Cindy−16−B−P..−....−A−...−..−SVA...

9.1 Port sizes / weight Port Port size O-Ring9.1 Port sizes / weight

A max. ø16 2.62x20.29

B max. ø16 2.62x20.29

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.9 kg

9.2 Standard model

38

83

A BX

MB 85 9

5

211

M10

28

75

33142

31.5

11.9

A B 37

.5

X

60

51

25

.51

5

ø25.3

ø25.3

ø8.6

M10x15/19

25.525.5

37.5

75

71

.9

60

38

11

0.5

83

max.ø16

max.ø16

max.ø4

X

A

B

Mounting surface

14

2

68

0.01 / 100mm

Rmax

10

X B

MB

A

Serial−No.

Nameplate

Issue: 09.2015 32/84 Reference: 300-P-9050013-EN-02

Page 33: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 33/84

9.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 33/84 Reference: 300-P-9050013-EN-02

Page 34: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 34/84

9.4 Characteristic curves (measured at 33 mm2/s [cSt])

9.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

9.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300

Flow rate [l/min]

∆p [b

ar]

9.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 34/84 Reference: 300-P-9050013-EN-02

Page 35: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 35/84

9.5 Model code key

S100 =

S150 =

S200 =

S240 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 16 B- - AP - -

16 mm

Nominal size

= 16

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010843..... 300 6010848..... 300 6010853.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 16−B−P−N−2−G300.0307134

Service packages Cindy 16−B−P−V−2−G300.0307140

Service packages Cindy 16−B−P−T−2−G300.0307146

Pilot−control types D, H

Art. No.

Service packages Cindy 16−B−P−N−2−D300.0307135

Service packages Cindy 16−B−P−V−2−D300.0307141

Service packages Cindy 16−B−P−T−2−D300.0307147

Issue: 09.2015 35/84 Reference: 300-P-9050013-EN-02

Page 36: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 36/84

10. Description Cindy−16−B−P..−....−L−...−..−SVA...

10.1 Port sizes / weight Port Port size O-Ring10.1 Port sizes / weight

A max. ø16 2.62x20.29

B max. ø16 2.62x20.29

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.9 kg

10.2 Standard model

38

70

83

A BX

MB

85

95

211

M10

28

75

33

L

142

31.5

11.9

A B

37

.5

L

X

60

51

25

.51

5

ø25.3ø8.6

ø8.6

M10x15/19

25.525.5

37.5

75

71

.9

60

38

70

11

0.583

max.ø16

max.ø16

max.ø4

X

L

A

B

Mounting surface

14

2

max.ø4ø25.3

68

0.01 / 100mm

Rmax

10

X B

MB

AL

Serial−No.

Nameplate

Issue: 09.2015 36/84 Reference: 300-P-9050013-EN-02

Page 37: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 37/84

10.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 37/84 Reference: 300-P-9050013-EN-02

Page 38: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 38/84

10.4 Characteristic curves (measured at 33 mm2/s [cSt])

10.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

10.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300

Flow rate [l/min]

∆p [b

ar]

10.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 38/84 Reference: 300-P-9050013-EN-02

Page 39: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 39/84

10.5 Model code key

S100 =

S150 =

S200 =

S240 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 16 B- - LP - -

16 mm

Nominal size

= 16

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010844..... 300 6010849..... 300 6010854.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 16−B−P−N−2−G300.0307134

Service packages Cindy 16−B−P−V−2−G300.0307140

Service packages Cindy 16−B−P−T−2−G300.0307146

Pilot−control types D, H

Art. No.

Service packages Cindy 16−B−P−N−2−D300.0307135

Service packages Cindy 16−B−P−V−2−D300.0307141

Service packages Cindy 16−B−P−T−2−D300.0307147

Issue: 09.2015 39/84 Reference: 300-P-9050013-EN-02

Page 40: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 40/84

11. Description Cindy−16−B−P..−....−L−...−..−SVT...

11.1 Port sizes / weight Port Port size O-Ring11.1 Port sizes / weight

A max. ø16 2.62x20.29

B max. ø16 2.62x20.29

T max. ø13 2.62x18.72

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.8 kg

11.2 Standard model

26

38

83

A BX

MB 85 95

211

M10

28

75

33

T

142

31.5

11.9

AB 3

7.5

TX

60

51

24

.52

5.5

15

ø25.3

ø25.3

ø8.6 ø23.5

max.ø13

M10x15/19

24.5

25.525.5

37.5

75

71

.9

60

38 2

6

11

0.58

3

max.ø16

max.ø16

max.ø4

X

T

A

B

Mounting surface

14

2

68

0.01 / 100mm

Rmax

10

X B

MB

A T

Serial−No.

Nameplate

Issue: 09.2015 40/84 Reference: 300-P-9050013-EN-02

Page 41: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 41/84

11.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

T

T

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 41/84 Reference: 300-P-9050013-EN-02

Page 42: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 42/84

11.4 Characteristic curves (measured at 33 mm2/s [cSt])

11.4.1 ∆p from A � B (Lifting) 20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

11.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300

Flow rate [l/min]

∆p [b

ar]

11.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 42/84 Reference: 300-P-9050013-EN-02

Page 43: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 43/84

11.5 Model code key

S100 =

S150 =

S200 =

S240 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 16 B- - LP - -

16 mm

Nominal size

= 16

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

Flow rate when lowering (spool size)

SVT

80 to 460 bar

Pressure setting

... =

Pressure relief from B to T

(tank line required)

Secondary pressure relief

SVT =

-

Independent of back pressure in A

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010845..... 300 6010850..... 300 6010855.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 16−B−P−N−3−G300.0307136

Service packages Cindy 16−B−P−V−3−G300.0307142

Service packages Cindy 16−B−P−T−3−G300.0307148

Pilot−control types D, H

Art. No.

Service packages Cindy 16−B−P−N−3−D300.0307137

Service packages Cindy 16−B−P−V−3−D300.0307143

Service packages Cindy 16−B−P−T−3−D300.0307149

Issue: 09.2015 43/84 Reference: 300-P-9050013-EN-02

Page 44: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 44/84

12. Description Cindy−20−B−P..−....−A−...−..

12.1 Port sizes / weight Port Port size O-Ring12.1 Port sizes / weight

A max. ø19 3.53x24.99

B max. ø19 3.53x24.99

X max. ø4 1.78x5.28

MB max. G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 5.0 kg

12.2 Standard model

36

83

A BX

MB

60 7

2

211

M12

28

75

33142

31.5

13.88

A B 37

.5

X

60

57

.16

28

.58

25

.5

15

ø31.7ø31.7

ø8.6

M12x15/19

25.5

28.5828.58

37.5

75

73

.88

60

36

11

0.583

max.ø19

max.ø19

max.ø4

X

A

B

Mounting surface

14

2

0.01 / 100mm

Rmax

10

X B

MB

Serial−No.

Nameplate

A

Issue: 09.2015 44/84 Reference: 300-P-9050013-EN-02

Page 45: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 45/84

12.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 45/84 Reference: 300-P-9050013-EN-02

Page 46: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 46/84

12.4 Characteristic curves (measured at 33 mm2/s [cSt])

12.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

12.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 46/84 Reference: 300-P-9050013-EN-02

Page 47: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 47/84

12.5 Model code key

S100 =

S150 =

S200 =

S240 =

S300 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 20 B- - AP - -

20 mm

Nominal size

= 20

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

S300

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010234..... 300 6010302..... 300 6010348.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 20−B−P−N−1−G300.0306975

Service packages Cindy 20−B−P−V−1−G300.0306981

Service packages Cindy 20−B−P−T−1−G300.0306987

Pilot−control types D, H

Art. No.

Service packages Cindy 20−B−P−N−1−D300.0306976

Service packages Cindy 20−B−P−V−1−D300.0306982

Service packages Cindy 20−B−P−T−1−D300.0306988

Issue: 09.2015 47/84 Reference: 300-P-9050013-EN-02

Page 48: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 48/84

13. Description Cindy−20−B−P..−....−L−...−..

13.1 Port sizes / weight Port Port size O-Ring13.1 Port sizes / weight

A max. ø19 3.53x24.99

B max. ø19 3.53x24.99

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 5.0 kg

13.2 Standard model

36

70

83

A BX

MB 60 7

2

211

M12

28

75

33

L

142

31.5

13.88

A B

37

.5

L

X

60

57

.16

28

.58

25

.5

15

ø31.7ø8.6

ø8.6

max.ø4

M12x15/19

25.5

28.5828.58

37.5

75

73

.88

70 60

36

11

0.5

83

max.ø19

max.ø19

max.ø4

X

L

A

B

Mounting surface

14

2

ø31.7

0.01 / 100mm

Rmax

10

X B

MB

AL

Serial−No.

Nameplate

Issue: 09.2015 48/84 Reference: 300-P-9050013-EN-02

Page 49: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 49/84

13.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 49/84 Reference: 300-P-9050013-EN-02

Page 50: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 50/84

13.4 Characteristic curves (measured at 33 mm2/s [cSt])

13.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

13.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

Issue: 09.2015 50/84 Reference: 300-P-9050013-EN-02

Page 51: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 51/84

13.5 Model code key

S100 =

S150 =

S200 =

S240 =

S300 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 20 B- - LP - -

20 mm

Nominal size

= 20

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

S300

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010235..... 300 6010303..... 300 6010349.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 20−B−P−N−1−G300.0306975

Service packages Cindy 20−B−P−V−1−G300.0306981

Service packages Cindy 20−B−P−T−1−G300.0306987

Pilot−control types D, H

Art. No.

Service packages Cindy 20−B−P−N−1−D300.0306976

Service packages Cindy 20−B−P−V−1−D300.0306982

Service packages Cindy 20−B−P−T−1−D300.0306988

Issue: 09.2015 51/84 Reference: 300-P-9050013-EN-02

Page 52: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 52/84

14. Description Cindy−20−B−P..−....−A−...−..−SVA...

14.1 Port sizes / weight Port Port Size O-Ring14.1 Port sizes / weight

A max. ø19 3.53x24.99

B max. ø19 3.53x24.99

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.9 kg

14.2 Standard model

36

83

A BX

MB 85 9

7

211

M12

28

75

33142

31.5

13.88

A B 37

.5

X

60

57

.16

28

.58

25

.5

15

ø31.7ø31.7

ø8.6

M12x15/19

25.5

28.5828.58

37.5

75

73

.88

60

36

11

0.5

83

max.ø19

max.ø19

max.ø4

X

A

B

Mounting surface

14

2

0.01 / 100mm

Rmax

10

X B

MB

A

Serial−No.

Nameplate

Issue: 09.2015 52/84 Reference: 300-P-9050013-EN-02

Page 53: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 53/84

14.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 53/84 Reference: 300-P-9050013-EN-02

Page 54: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 54/84

14.4 Characteristic curves (measured at 33 mm2/s [cSt])

14.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

14.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

14.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 54/84 Reference: 300-P-9050013-EN-02

Page 55: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 55/84

14.5 Model code key

S100 =

S150 =

S200 =

S240 =

S300 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 20 B- - AP - -

20 mm

Nominal size

= 20

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

S300

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010236..... 300 6010304..... 300 6010350.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 20−B−P−N−2−G300.0306977

Service packages Cindy 20−B−P−V−2−G300.0306983

Service packages Cindy 20−B−P−T−2−G300.0306989

Pilot−control types D, H

Art. No.

Service packages Cindy 20−B−P−N−2−D300.0306978

Service packages Cindy 20−B−P−V−2−D300.0306984

Service packages Cindy 20−B−P−T−2−D300.0306990

Issue: 09.2015 55/84 Reference: 300-P-9050013-EN-02

Page 56: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 56/84

15. Description Cindy−20−B−P..−....−L−...−..−SVA...

15.1 Port sizes / weight Port Port size O-Ring15.1 Port sizes / weight

A max. ø19 3.53x24.99

B max. ø19 3.53x24.99

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.9 kg

15.2 Standard model

36

70

83

A BX

MB

85 9

7

211

M12

28

75

33

L

142

31.5

13.88

A B 37

.5

L

X

60

57

.16

28

.58

25

.5

15

ø31.7ø8.6

ø8.6

M12x15/19

25.5

28.5828.58

37.5

75

73

.88

70

60 36

11

0.58

3

max.ø19

max.ø19

max.ø4

X

L

A

B

Mounting surface

14

2

max.ø4ø31.7

68

0.01 / 100mm

Rmax

10

X B

MB

AL

Serial−No.

Nameplate

Issue: 09.2015 56/84 Reference: 300-P-9050013-EN-02

Page 57: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 57/84

15.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 57/84 Reference: 300-P-9050013-EN-02

Page 58: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 58/84

15.4 Characteristic curves (measured at 33 mm2/s [cSt])

15.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

15.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

15.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 58/84 Reference: 300-P-9050013-EN-02

Page 59: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 59/84

15.5 Model code key

S100 =

S150 =

S200 =

S240 =

S300 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 20 B- - LP - -

20 mm

Nominal size

= 20

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

S300

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010237..... 300 6010305..... 300 6010351.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 20−B−P−N−2−G300.0306977

Service packages Cindy 20−B−P−V−2−G300.0306983

Service packages Cindy 20−B−P−T−2−G300.0306989

Pilot−control types D, H

Art. No.

Service packages Cindy 20−B−P−N−2−D300.0306978

Service packages Cindy 20−B−P−V−2−D300.0306984

Service packages Cindy 20−B−P−T−2−D300.0306990

Issue: 09.2015 59/84 Reference: 300-P-9050013-EN-02

Page 60: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 60/84

16. Description Cindy−20−B−P..−....−L−...−..−SVT...

16.1 Port sizes / weight Port Port size O-Ring16.1 Port sizes / weight

A max. ø19 3.53x24.99

B max. ø19 3.53x24.99

T max. ø13 2.62x18.72

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 6.8 kg

16.2 Standard model

19

36

83

A BX

MB 85 9

7

211

M12

28

75

33

T

142

31.5

13.88

A B 37

.5

TX

60

57

.1624

.52

8.5

8

25

.5

15

ø31.7ø31.7

ø8.6 ø23.5

max.ø13M12x15/19

25.5

24.5

28.5828.58

37.5

75

73

.88

60

36

19

11

0.58

3

max.ø19

max.ø19

max.ø4

X

T

A

B

Mounting surface

14

2

68

0.01 / 100mm

Rmax

10

X B

MB

A T

Serial−No.

Nameplate

Issue: 09.2015 60/84 Reference: 300-P-9050013-EN-02

Page 61: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 61/84

16.3 Pilot−control variants (each can be rotated through 180°)

A/F 22

A/F 6

37

.5

app.22 45

63

.55

0

28

50

28

A/F 22

A/F 6

16.5 45

37

.5

63

.5

MB

AX B

MB

AX B

T

T

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 61/84 Reference: 300-P-9050013-EN-02

Page 62: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 62/84

16.4 Characteristic curves (measured at 33 mm2/s [cSt])

16.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

16.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

16.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 62/84 Reference: 300-P-9050013-EN-02

Page 63: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 63/84

16.5 Model code key

S100 =

S150 =

S200 =

S240 =

S300 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 20 B- - LP - -

20 mm

Nominal size

= 20

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S100

S150

S200

S240

S300

Flow rate when lowering (spool size)

SVT

80 to 460 bar

Pressure setting

... =

Pressure relief from B to T

(tank line required)

Secondary pressure relief

SVT =

-

Independent of back pressure in A

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010238..... 300 6010306..... 300 6010352.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 20−B−P−N−3−G300.0306979

Service packages Cindy 20−B−P−V−3−G300.0306985

Service packages Cindy 20−B−P−T−3−G300.0307000

Pilot−control types D, H

Art. No.

Service packages Cindy 20−B−P−N−3−D300.0306980

Service packages Cindy 20−B−P−V−3−D300.0306986

Service packages Cindy 20−B−P−T−3−D300.0307001

Issue: 09.2015 63/84 Reference: 300-P-9050013-EN-02

Page 64: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 64/84

17. Description Cindy−25−B−P..−....−A−...−..

17.1 Port sizes / weight Port Port size O-Ring17.1 Port sizes / weight

A max. ø27 3.53x37.69

B max. ø30.5 3.53x37.69

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 8.5 kg

17.2 Standard model

54.5

103

A BX

MB

75 76

246.5

M14

39

9235.5

175

40

15.88

AB 4

6

X

80

66

.68

33

.34

25

.5

18

.5

ø44.4ø44.4

ø8.6

max.ø30.5

M14x18.5/22.5

13

5

25.5

30

33.3433.34

46

92

10

3 80

54

.5

15

.88

80

max.ø30.5

max.ø4X

A

B

17

5

Mounting surface

0.01 / 100mm

Rmax

10

Serial−No.

Nameplate

X B

MB

A

Issue: 09.2015 64/84 Reference: 300-P-9050013-EN-02

Page 65: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 65/84

17.3 Pilot−control variants (each can be rotated through 180°)

app. 22 45

46

63

.5

B

MB

AX

B

MB

AX

50

39

16.5 45

46

63

.55

0

39

A/F 6

A/F 22

A/F 22

A/F 6

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 65/84 Reference: 300-P-9050013-EN-02

Page 66: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 66/84

17.4 Characteristic curves (measured at 33 mm2/s [cSt])

17.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

17.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

Issue: 09.2015 66/84 Reference: 300-P-9050013-EN-02

Page 67: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 67/84

17.5 Model code key

S250 =

S400 =

S500 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 25 B- - AP - -

25 mm

Nominal size

= 25

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S250

S400

S500

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010239..... 300 6010307..... 300 6010353.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 25−B−P−N−1−G300.0307002

Service packages Cindy 25−B−P−V−1−G300.0307008

Service packages Cindy 25−B−P−T−1−G300.0307014

Pilot−control types D, H

Art. No.

Service packages Cindy 25−B−P−N−1−D300.0307003

Service packages Cindy 25−B−P−V−1−D300.0307009

Service packages Cindy 25−B−P−T−1−D300.0307015

Issue: 09.2015 67/84 Reference: 300-P-9050013-EN-02

Page 68: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 68/84

18. Description Cindy−25−B−P..−....−L−...−..

18.1 Port sizes / weight Port Port size O-Ring18.1 Port sizes / weight

A max. ø27 3.53x37.69

B max. ø30.5 3.53x37.69

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 8.5 kg

18.2 Standard model

54.5

91

103

A BX

MB

75

76

246.5

M14

39

9235.5

175

40

15.88

A B 46

X

80

66

.68

33

.34

25

.5

18

.5

ø44.4ø44.4

ø8.6

max.ø30.5

M14x18.5/22.5

13

5

25.5

33.3433.34

46

92

10

3 80

54

.5

15

.88

80

max.ø4

max.ø30.5

max.ø4X

L

A

B1

75

Mounting surface

ø8.6

L

L

91

0.01 / 100mm

Rmax

10

X B

MB

AL

Serial−No.

Nameplate

Issue: 09.2015 68/84 Reference: 300-P-9050013-EN-02

Page 69: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 69/84

18.3 Pilot−control variants (each can be rotated through 180°)

app. 22 45

46

63

.5

B

MB

AX

B

MB

AX

50

39

16.5 45

46

63

.55

0

39

A/F 6

A/F 22

A/F 22

A/F 6

L

L

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 69/84 Reference: 300-P-9050013-EN-02

Page 70: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 70/84

18.4 Characteristic curves (measured at 33 mm2/s [cSt])

18.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

18.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

Issue: 09.2015 70/84 Reference: 300-P-9050013-EN-02

Page 71: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 71/84

18.5 Model code key

S250 =

S400 =

S500 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 25 B- - LP - -

25 mm

Nominal size

= 25

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S250

S400

S500

Flow rate when lowering (spool size)

Seal material NITRILE VITON LOW-TEMP

Art. No. for basic valve(without specific features)

300 6010240..... 300 6010308..... 300 6010354.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 25−B−P−N−1−G300.0307002

Service packages Cindy 25−B−P−V−1−G300.0307008

Service packages Cindy 25−B−P−T−1−G300.0307014

Pilot−control types D, H

Art. No.

Service packages Cindy 25−B−P−N−1−D300.0307003

Service packages Cindy 25−B−P−V−1−D300.0307009

Service packages Cindy 25−B−P−T−1−D300.0307015

Issue: 09.2015 71/84 Reference: 300-P-9050013-EN-02

Page 72: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 72/84

19. Description Cindy−25−B−P..−....−A−...−..−SVA...

19.1 Port sizes / weight Port Port size O-Ring19.1 Port sizes / weight

A max. ø27 3.53x37.69

B max. ø30.5 3.53x37.69

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 13.3 kg

19.2 Standard model

54.5

103

A BX

MB

11

4.5

11

5.5

88

246.5

M14

39

9235.5

175

40

15.88

A B 46

X

806

6.6

8

33

.34

25

.5

18

.5

ø44.4ø44.4

ø8.6

max.ø30.5

M14x18.5/22.5

13

5

25.5

33.3433.34

46

92

10

3 80

54

.5

15

.88

80

max.ø30.5

max.ø4X

A

B

17

5

Mounting surface

0.01 / 100mm

Rmax

10

Serial−No.

Nameplate

X B

MB

A

Issue: 09.2015 72/84 Reference: 300-P-9050013-EN-02

Page 73: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 73/84

19.3 Pilot−control variants (each can be rotated through 180°)

app. 22 454

6

63

.5

B

MB

AX

B

MB

AX

50

39

16.5 45

46

63

.55

0

39

A/F 6

A/F 22

A/F 22

A/F 6

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 73/84 Reference: 300-P-9050013-EN-02

Page 74: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 74/84

19.4 Characteristic curves (measured at 33 mm2/s [cSt])

19.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

19.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

19.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 74/84 Reference: 300-P-9050013-EN-02

Page 75: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 75/84

19.5 Model code key

S250 =

S400 =

S500 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 25 B- - AP - -

25 mm

Nominal size

= 25

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S250

S400

S500

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Dependent on back pressure in A (control pressure must be

increased by amount of back pressure; drain line not needed)

Influence of return line (back pressure) to pilot-pressure

A=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010241..... 300 6010309..... 300 6010355.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 25−B−P−N−2−G300.0307004

Service packages Cindy 25−B−P−V−2−G300.0307010

Service packages Cindy 25−B−P−T−2−G300.0307016

Pilot−control types D, H

Art. No.

Service packages Cindy 25−B−P−N−2−D300.0307005

Service packages Cindy 25−B−P−V−2−D300.0307011

Service packages Cindy 25−B−P−T−2−D300.0307017

Issue: 09.2015 75/84 Reference: 300-P-9050013-EN-02

Page 76: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 76/84

20.Description Cindy−25−B−P..−....−L−...−..−SVA...

20.1 Port sizes / weight Port Port size O-Ring20.1 Port sizes / weight

A max. ø27 3.53x37.69

B max. ø30.5 3.53x37.69

X, L max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 13.3 kg

20.2Standard model

54.5

91

103

A BX

MB 11

4.5

11

5.5

246.5

M14

39

9235.5

175

40

15.88

AB 4

6

X

806

6.6

8

33

.34

25

.5

18

.5

ø44.4ø44.4

ø8.6

max.ø30.5

M14x18.5/22.5

13

5

25.5

33.3433.34

46

92

10

3 80 5

4.5

15

.88

80

max.ø4

max.ø30.5

max.ø4X

L

A

B1

75

Mounting surface

ø8.6

L

L

91

88

0.01 / 100mm

Rmax

10

AL

Serial−No.

Nameplate

X

MB

B

Issue: 09.2015 76/84 Reference: 300-P-9050013-EN-02

Page 77: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 77/84

20.3Pilot−control variants (each can be rotated through 180°)

app. 22 454

6

63

.5

B

MB

AX L

B

MB

AX L

50

39

16.5 45

46

63

.55

0

39

A/F 6

A/F 22

A/F 22

A/F 6

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 77/84 Reference: 300-P-9050013-EN-02

Page 78: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 78/84

20.4Characteristic curves (measured at 33 mm2/s [cSt])

20.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

20.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

20.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 78/84 Reference: 300-P-9050013-EN-02

Page 79: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 79/84

20.5Model code key

S250 =

S400 =

S500 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 25 B- - LP - -

25 mm

Nominal size

= 25

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S250

S400

S500

Flow rate when lowering (spool size)

SVA

80 to 460 bar

Pressure setting

... =

Pressure relief from B to A

Secondary pressure relief

SVA =

-

Independent of back pressure in A (drain line required)

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010242..... 300 6010310..... 300 6010356.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 25−B−P−N−2−G300.0307004

Service packages Cindy 25−B−P−V−2−G300.0307010

Service packages Cindy 25−B−P−T−2−G300.0307016

Pilot−control types D, H

Art. No.

Service packages Cindy 25−B−P−N−2−D300.0307005

Service packages Cindy 25−B−P−V−2−D300.0307011

Service packages Cindy 25−B−P−T−2−D300.0307017

Issue: 09.2015 79/84 Reference: 300-P-9050013-EN-02

Page 80: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 80/84

21. Description Cindy−25−B−P..−....−L−...−..−SVT...

21.1 Port sizes / weight Port Port size O-Ring21.1 Port sizes / weight

A max. ø27 3.53x37.69

B max. ø30.5 3.53x37.69

T max. ø18 2.62x23.47

X max. ø4 1.78x5.28

MB G 1/4" −

For tightening torques, see Cindy General

Information leaflet, section 6. Weight: approx. 13.0 kg

21.2 Standard model

27

54.5

103

A BX

MB

11

4.5

11

5.5

88

246.5

M14

39

9235.5

T

175

40

15.88

A B 46

T

X

806

6.6

8

30

33

.34

25

.5

18

.5

ø44.4ø44.4

ø8.6ø28.5

max.ø30.5

M14x18.5/22.5

13

5

25.5

30

33.3433.34

46

92

10

3 80

54

.5

27

15

.88

80

max.ø18

max.ø30.5

max.ø4X

TA

B1

75

Mounting surface

0.01 / 100mm

Rmax

10

X B

MBSerial−No.

Nameplate

A T

Issue: 09.2015 80/84 Reference: 300-P-9050013-EN-02

Page 81: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 81/84

21.3 Pilot−control variants (each can be rotated through 180°)

app. 22 454

6

63

.5

B

MB

AX T

B

MB

AX T

50

39

16.5 45

46

63

.55

0

39

A/F 6

A/F 22

A/F 22

A/F 6

Pilot−control with the �damping cover" (D)

Pilot−control with the �hydro−mechanical stroke limiter" (H)

Issue: 09.2015 81/84 Reference: 300-P-9050013-EN-02

Page 82: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 82/84

21.4 Characteristic curves (measured at 33 mm2/s [cSt])

21.4.1 ∆p from A � B (Lifting)20

15

10

5

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

21.4.2 ∆p from B � A(Lowering; spool fully open)

40

30

20

10

00 50 100 150 200 250 300 350

Flow rate [l/min]

∆p [b

ar]

400 450 500

21.4.3 Opening characteristic of thesecondary pressure reliefvalve

50

Flow rate [l/min]

Load

pre

ssur

e B

[bar

]

0

500

400

300

200

100

0

100 150 250200

Setting: 380 bar

Setting: 250 bar

Issue: 09.2015 82/84 Reference: 300-P-9050013-EN-02

Page 83: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 83/84

21.5 Model code key

S250 =

S400 =

S500 =

Leak− free

load control valve

Valve series

= CINDY

CINDY 25 B- - LP - -

25 mm

Nominal size

= 25

B

Version

Manifold mounting design

Application / valve type

= P

Type 1 ... 99

Orifice combinations

.. =

- -

= B

-

Temperature range

Nitrile (standard) −20°C to +80°C

Nitrile (low temperature) −50°C to +80°C

Viton −20°C to +200°C

Seal material

= N

= T

= V

Without fixing screws

Black fixing screws

�Dacromate" fixing screws (anti−corrosion)

Fixing screws

= O

= S

= D

Pilot-control options

Pilot−control with �standard cover"

Pilot−control with �damping cover"

Pilot−control with �hydro−mechanical stroke limiter"

G.. =

D.. =

H.. =

(see General Information Leaflet, section 9.)

(see General Information Leaflet, section 9.)

S250

S400

S500

Flow rate when lowering (spool size)

SVT

80 to 460 bar

Pressure setting

... =

Pressure relief from B to T

(tank line required)

Secondary pressure relief

SVT =

-

Independent of back pressure in A

Influence of return line (back pressure) to pilot-pressure

L=

Seal material NITRILE VITON LOW-TEMP.

Art. No. for basic valve(without specific features)

300 6010243..... 300 6010311..... 300 6010357.....

Service packages

Pilot−control type G

Art. No.

Service packages Cindy 25−B−P−N−3−G300.0307006

Service packages Cindy 25−B−P−V−3−G300.0307012

Service packages Cindy 25−B−P−T−3−G300.0307018

Pilot−control types D, H

Art. No.

Service packages Cindy 25−B−P−N−3−D300.0307007

Service packages Cindy 25−B−P−V−3−D300.0307013

Service packages Cindy 25−B−P−T−3−D300.0307019

Issue: 09.2015 83/84 Reference: 300-P-9050013-EN-02

Page 84: Safety for Hydraulics Cindy Leak−Free Load Control Valves ... · Safety for Hydraulics Cindy" Leak−Free Load Control Valves, Manifold Mounting Design 300−P−9050013−E−02/03.04

300−P−9050013−E−02/03.04 84/84

Germany

Phone +49 7742 85 20Fax +49 7742 71 [email protected]

BUCHER HYDRAULICS www.bucherhydraulics.com

France

Phone +33 389 64 22 44Fax +33 389 65 28 [email protected]

Netherlands

Phone +31 79 34 26 24 4Fax +31 79 34 26 28 [email protected]

UK

Phone +44 24 76 35 35 61Fax +44 24 76 35 35 [email protected]

Switzerland

Phone +41 33 67 26 11 1Fax +41 33 67 26 10 [email protected]

Italy

Phone +39 0522 92 84 11Fax +39 0522 51 32 [email protected]

Austria

Phone +43 6216 44 97Fax +43 6216 44 97 [email protected]

China

Phone +86 10 64 44 32 38Fax +86 10 64 44 32 [email protected]

Product Center (Elevator)

Phone +41 41 757 03 33Fax +41 41 757 16 [email protected]

USA

Phone +1 262 605 82 80Fax +1 262 605 82 [email protected]

We reserve the right of modification without notice.

Issue: 09.2015 84/84 Reference: 300-P-9050013-EN-02

schneidb
Textfeld
[email protected] www.bucherhydraulics.com Bucher Hydraulics AG, CH-6345 Neuheim All rights reserved Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue.