SACE Tmax XT XT2-XT4 Sganciatori Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 Release Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 Auslöser Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 Dèclencheur Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 Relé Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 A XT2-XT4 1 XT2 XT4 Doc. N.° 1SDH000721R0507 - B0399 1 2 电子脱扣器Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4 1SDH000721R0507 * fold this paper with barcode on the outer side

Upload: lynga

Post on 16-Feb-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

SACE Tmax XT

XT2-XT4

Sganciatori Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

Release Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

Auslser Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

Dclencheur Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

Rel Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

A XT2-XT4

1XT2 XT4

Doc. N. 1SDH000721R0507 - B0399

1

2

Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4

1SDH000721R0507

* fold this paper with barcode on the outer side

SACE Tmax | ABB

B Ekip G-LS/I - XT2-XT4 III/IV - IEC ONLY

C Ekip N-LS/I - XT2-XT4 IV - IEC ONLY

In = 100 AI1 = 100 x (0,4+0,08+0,32)= 80At1= 6 s @240 A (3I )

1

Esempio:

Example:

tL

t1

I

I3I1 I

I2 =100 x (1,5+2)=350AIn=100 AEsempio:

t2= 0,2 s @ In>I2

Default settingDefault-EinstellungConfiguration par dfauit Ajuste de default

Green

L Red LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I > 1,2 * I1)

S Red

L | S | I Red

LED ON (fixed) = Device active

LED Blinking = S alarm (I > I2)

LED Blinking = Parameters inconsistency - L = S or L = I.

LED Blinking without Parameters inconsistency = generic fault (please contact ABB)

LED Color CONDITION Run time

Example:

1

Default settingDefault-EinstellungConfiguration par dfauit Ajuste de default

Green

L Red LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I > 1,2 * I1)

S Red

L | S | I Red

LED ON (fixed) = Device active

LED Blinking = S alarm (I > I2)

LED Blinking = Parameters inconsistency - L = S or L = I.

LED Blinking without Parameters inconsistency = generic fault (please contact ABB)

LED Color CONDITION Run time

tL

t1

I

I3I1 I I

t

S

L

I2I1

In = 100 AI1 = 100 x (0,4+0,08+0,32)= 80At1= 12 s @240 A (3I )1

Esempio:

Example:

Example:

I2 =100 x (1,5+2)=350AIn=100 A

Esempio:

t2= 0,2 s @ In>I2

N = ONN = 100%

Esempio:

Example:

1

2

2

t2

I

t

S

L

I2I1

t2

SACE Tmax | ABB

D Ekip M-LIU - XT2-XT4 III - IEC/UL

E Ekip M-I - XT2-XT4 III - IEC ONLY

Green

L Red LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I > 1,2 * I1)

U Red

L | U | I Red

LED ON (fixed) = Device active

LED Blinking = Parameters inconsistency - L = I.

LED Blinking without Parameters inconsistency = generic fault (please contact ABB)

LED Color CONDITION Run time

LED Blinking = U alarm

t6

I6

3E 2s

F XT2-XT4

CLACK4

1PROCEDURA DI CONTROLLO- CONTROLLO LED: tutti i led del rel si devono accendere- ULTIMA INDICAZIONE DI TRIP: se presente nella memoria del rel- LED: resta acceso finch lunit TT e connessa al rel

- PRONTO PER TRIP

DIAGNOSTIC PROCEED- UNIT CHECK LED: all the leds in the relay must come on- LAST TRIP INDICATION: if present in the relay's data store- LED: remains on for as long as the TT is connected to the relay- READY TO TRIP

DIAGISTIKABLAUF- EINEITHSPRUF-LED: Alle LEDs des Relais mssen aufleuchten- ANGABE DER LETZTEN AUSLOSUNG: Wenn im Speicher des Relais vorhanden.- LED: Bleibt angeschaltet, bis die Einheit TT an die Relais angeschlossen ist.- AUSLOSEBEREIT

PROCEDIMIENTO DIAGNOSTICO- LED CONTROL UNIDAD: todos los led del rel se deben encender- INDICACION ULTIMA ACTUACION: si est presente en la memoria del rel- LED: queda encendido mientras la unidad TT permanezca conectada con el rel- LISTO PARA LA ACTUACION

PROCDURE DE DIAGNOSTIC- UNIT CHECK LED : toutes les diodes du relais doivent s'allumer- LAST TRIP INDICATION : si prsente dans la mmoire du relais- LED: la DIODE reste allume tant que l'unit TT est connecte au relais- READY TO TRIP

- :

-

- LED: TT

-

Copyright 2010-2015 ABB. All rights reserved www.abb.com

VerdeGreenGrnVert

Verde

RossoRedRot

RougeRojo

Dispositivo accesoDevice ON

Einrichtung eingeschaltetDispositif allum

Dispositivo encendido

Sostituire batterieChange battery

Batterie ersetzenRemplacer batteries

Sustituir bateras

LED Ekip TT

3TRIP

2