s8cr-3100g-of378s-y issue: 13/02/2017 page: 1 of 4 copyrigt · s8cr-3100g-of378s-y issue:...
TRANSCRIPT
![Page 1: S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 1 of 4 Copyrigt · S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 3 of 4 For reerence purposes ony is raing is not a VSHFL¿FDWLRQ 2UGHUDJDLQVWSURGXFWFRGHRQO\](https://reader036.vdocuments.site/reader036/viewer/2022071018/5fd1d15d0432aa1188150aac/html5/thumbnails/1.jpg)
45” diameter x 33” deep sump base to fit 42” tank collar ring, tophat and watertight platform for (1) 5-gallon spill buckets. 36” diameter offset cover, port cover, frame and skirt.
S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 1 of 4
For reference purposes only. This drawing is not a specification. Order against product code only. To enable continuous improvement of our products, the designs and specifications are subject to change without notice.
© Copyright
![Page 2: S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 1 of 4 Copyrigt · S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 3 of 4 For reerence purposes ony is raing is not a VSHFL¿FDWLRQ 2UGHUDJDLQVWSURGXFWFRGHRQO\](https://reader036.vdocuments.site/reader036/viewer/2022071018/5fd1d15d0432aa1188150aac/html5/thumbnails/2.jpg)
45” diameter x 33” deep sump base to fit 42” tank collar ring, tophat and watertight platform for (1) 5-gallon spill buckets. 36” diameter offset cover, port cover, frame and skirt.
S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 2 of 4
For reference purposes only. This drawing is not a specification. Order against product code only. To enable continuous improvement of our products, the designs and specifications are subject to change without notice.
© Copyright
SC-COLOROPTIONAL SEALABLEFILL PORT COVERS
FC-11-YELLOW
FLMP-IP INSPECTION PORT
FL100-OF8S COVER
FL100F FRAME
WSP37-8S WATERSHROUD PLATFORM
FL100-SK12 SKIRT
S8-3100-TH TOP HAT
P761C-FLDV SPILLCONTAINER DRAIN VALVE
S8CR SUMP BASE
RETAINER RING
FLMP-SB SHROUD BOOT KIT
WSP-CRKS CLAMPING RING KITS
210469 OBSERVATION CAP S/A
Item Description Qty61SALP-1020-EVR Fill Swivel Adapter,
Brass1
634TT-7085-EVR Fill Cap, Gray 1H12807M Fill Nipple, 12”
Length1
FSA-400-S Face Seal Adapter 161JSK-44CB Jack Screw
Assembly1
71SO-T Testable Overfill Prevention Valve
1
![Page 3: S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 1 of 4 Copyrigt · S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 3 of 4 For reerence purposes ony is raing is not a VSHFL¿FDWLRQ 2UGHUDJDLQVWSURGXFWFRGHRQO\](https://reader036.vdocuments.site/reader036/viewer/2022071018/5fd1d15d0432aa1188150aac/html5/thumbnails/3.jpg)
45” diameter x 33” deep sump base to fit 42” tank collar ring, tophat and watertight platform for (1) 5-gallon spill buckets. 36” diameter offset cover, port cover, frame and skirt.
S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 3 of 4
For reference purposes only. This drawing is not a specification. Order against product code only. To enable continuous improvement of our products, the designs and specifications are subject to change without notice.
© Copyright
Ø4314"
8"
40316" A/F
331 4"
1015
16"
56" M
AX
12"
MAX TRIM
45916" A/F
4458" A/F
3116
"
115 16
"11
1316
"44
" MIN
X
X
210469 OBSERVATION CAP S/A
FLMP-IP INSPECTION PORT
SECTION X - X
FL100-OF8S COVER
FC-11 FILL COVER
FL100F FRAME
FLMP-SB SHROUD BOOT
WSP37-8S WATER SHROUD PLATFORM
FL100-SK12 SKIRT
S8-3100-TH TOP HAT WITH RING
S8CR SUMP BASE
P761C-FLDV SPILLCONTAINER DRAIN VALVE
233 16
"
WSP-CRKS CLAMPING RING KIT
123 16
"
678"
![Page 4: S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 1 of 4 Copyrigt · S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 3 of 4 For reerence purposes ony is raing is not a VSHFL¿FDWLRQ 2UGHUDJDLQVWSURGXFWFRGHRQO\](https://reader036.vdocuments.site/reader036/viewer/2022071018/5fd1d15d0432aa1188150aac/html5/thumbnails/4.jpg)
45” diameter x 33” deep sump base to fit 42” tank collar ring, tophat and watertight platform for (1) 5-gallon spill buckets. 36” diameter offset cover, port cover, frame and skirt.
S8CR-3100G-OF378S-Y Issue: 13/02/2017 Page: 4 of 4
For reference purposes only. This drawing is not a specification. Order against product code only. To enable continuous improvement of our products, the designs and specifications are subject to change without notice.
© Copyright
CONCRETE
121/2
"A"
20
Minimum8
Maximum14
VERY IMPORTANTThe underside of the framemust be adequatelysupported by concrete.
Concrete reinforcedwith 2 layers of reinforcement mesh.
Joint tied with24” long x12mm dowel at 24” c/c.Half bonded
CONCRETE PEA GRAVEL
TYPICAL INSTALLATION
VERY IMPORTANTFRAMES MUST BE INSTALLED FLUSHWITH FINISHED GRADE OR SET SLIGHTLYBELOW FINISHED GRADE TO PROTECTFROM SNOWPLOW DAMAGE
VERY IMPORTANTTo allow for drainage, Fibrelite recommends that the concrete be sloped away from the top
outer edge of the frame (A) a minimum of 1/2” over a 12” distance. Do not expose the top outer edge of the frame (A) – the concrete pad must be flush with the top outer edge of the frame.