s3602c vector network analyzer datasheet - saluki tec · 2017-09-21 · s3602c vector network...

18
S3602C Vector Network Analyzer Datasheet Saluki Technology Inc.

Upload: others

Post on 02-Jun-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

S3602C Vector Network Analyzer Datasheet

Saluki Technology Inc.

Page 2: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2

The document applies to the vector network analyzers of the following models: S3602C vector network analyzer (10MHz - 43.5GHz).

Options of the S3602C vector network analyzer in addition to standard accessories: Part No. Name Description

S3602C-201 2-ports, single source, with extended power

range

The 2-ports test set with extended power range comes with a configurable test set, source and receiver attenuators at each port. The source attenuators are 60 dB and the receiver attenuators are 35 dB.

S3602C-400 4-ports, dual source, base configuration The 4-port configurable test set comes with two internal sources.

S3602C-401 4-ports, dual source, with extended power

range (Need option 400)

The 4-ports test set with extended power range comes with a configurable test set, source and receiver attenuators at each port. The source attenuators are 60 dB and the receiver attenuators are 35 dB. (Option 400 required)

S3602B-402 Inter-modulation distortion application Enable S3602 to set up and calibrate swept-IMD measurements of both amplifiers and frequency converters. (Option 400 required, for converter measurement Option S82 or S83 is required))

S3602C-008 Pulsed RF Measurements Applicable for S Parameter Measurement under pulse conditions

S3602C-S10 Time Domain Measurement Able to recognize and analyze the discontinuous location of the network, cable or fixture .

S3602C-S80 Frequency offset measurements Applicable for frequency offset measurement, necessary for millimeter extenders.

S3602C-S82 Scalar calibrated converter measurements

( Need Option 400)

Enable S3602 for the converter scalar measurement (Option 400 required). Converter scalar measurement needs power sensor/power meter. Power sensor/power meter is not covered in this option

S3602C-S83 Vector calibrated converter measurements

( Need Option 400)

Enable S3602 for the converter vector/scalar measurement (Option 400 required). Converter vector measurement needs calibration and reference mixers. They are not covered in this option.Converter scalar measurement needs power sensor/power meter. Power sensor/power meter is not covered in this option

S3602C-S84 Embedded LO measurements

( Need Option 400)

Enable S3602 for the embedded LO frequency converter measurement (Option 400 required)

S3602C-S86 Gain compression application Enable S3602 for the gain compression measurement of amplifier

SAV31123A 2.4mm Calibration kit Mechanical calibration kit, applicable for Whole-Machine Calibration

FE0BN0BM025.0 2.4mm Test Cable (Male DUT end) Applicable for Whole-Machine Measurement

FE0BN0BL025.0 2.4mm Test Cable (Female DUT end) Applicable for Whole-Machine Measurement

Page 3: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

3

Part No. Name Description

SAV20404 Electronic Calibration kit E-cal kit, applicable for Whole-Machine Calibration (10MHz-50GHz, 2 port)

SCAVNA50FM-(2.4/2.4) 2.4mm Test Cable (Male DUT end) 63cm VNA test cable, applicable for Whole-Machine Measurement

SCAVNA50FF-(2.4/2.4) 2.4mm Test Cable (Female DUT end) 63cm VNA test cable, applicable for Whole-Machine Measurement

Page 4: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

4

Preface Thanks for choosing S3602 vector network analyzer produced by Saluki Technology Inc.

We devote ourselves to meeting your demands, providing you high-quality measuring instrument and the best after-sales service. We persist with “superior quality and considerate service”, and are committed to offering satisfactory products and service for our clients.

Document No. S3602-02-02

Version Rev03 2017.02

Saluki Technology

Document Authorization The information contained in this document is subject to change without notice. The power to interpret the contents of and terms used in this document rests with Saluki.

Saluki Tech owns the copyright of this document which should not be modified or tampered by any organization or individual, or reproduced or transmitted for the purpose of making profit without its prior permission, otherwise Saluki will reserve the right to investigate and affix legal liability of infringement.

Product Quality Assurance The warranty period of the product is 36 months from the date of delivery. The instrument manufacturer will repair or replace damaged parts according to the actual situation within the warranty period.

Product Quality Certificate The product meets the indicator requirements of the document at the time of delivery. Calibration and measurement are completed by the measuring organization with qualifications specified by the state, and relevant data are provided for reference.

Quality/Settings Management Research, development, manufacturing and testing of the product comply with the requirements of the quality and environmental management system.

Page 5: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

5

Contacts

Service Tel: 886.2.2175 2930

Website: www.salukitec.com

Email: [email protected]

Address: No. 367 Fuxing N Road, Taipei 105,Taiwan (R.O.C.)

Page 6: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

6

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

Content

1. Overview ............................................................................................................................................................................................... 7 2. Specifications ........................................................................................................................................................................................ 8

2.1. Frequency ................................................................................................................................................................................. 8 2.2. Test Port Specification ............................................................................................................................................................... 8

2.2.1. Maximum Output Power ................................................................................................................................................ 8 2.2.2. Output Power Setting Range ....................................................................................................................................... 11 2.2.3. Minimum Stable Output Power .................................................................................................................................... 11 2.2.4. Power Resolution ........................................................................................................................................................ 11 2.2.5. Temperature Stability ................................................................................................................................................... 11 2.2.6. Power Accuracy ........................................................................................................................................................... 12 2.2.7. Port Damage Level ...................................................................................................................................................... 12 2.2.8. Power Sweep Range ................................................................................................................................................... 12 2.2.9. 1dB Compression Point ............................................................................................................................................... 12 2.2.10. Power Linearity .......................................................................................................................................................... 12 2.2.11. Port Harmonics Suppression ..................................................................................................................................... 12

2.3. Network Specifications ............................................................................................................................................................ 13 2.3.1. System Dynamic Range .............................................................................................................................................. 13 2.3.2. Phase Noise ................................................................................................................................................................ 13 2.3.3. Noise Floor .................................................................................................................................................................. 14 2.3.4. Corrected System Performance .................................................................................................................................. 14 2.3.5. Trace Noise ................................................................................................................................................................. 16

2.4. Pulse Specifications ................................................................................................................................................................ 16 2.5. General.................................................................................................................................................................................... 17 2.6. Compliant ................................................................................................................................................................................ 18

2.6.1. CE ................................................................................................................................................................................ 18 2.6.2. ISO .............................................................................................................................................................................. 18

Page 7: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

7

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

1. Overview S3602 Series VNA is a top level VNA with excellent specifications. Its frequency ranges from 10MHz to 67GHz. With Saluki frequency extension modules, S3602 can reach 325GHz. S3602 has a wide dynamic range, low trace noise, flexible interfaces and friendly UI.

S3602 series VNA can be universally implemented in fields including transmission/reception module measurement, dielectric material property measurement, microwave pulse characteristic measurement and photoelectric property measurement; It is a necessary instrument in the scientific research, production process of systems like radar, communication and navigation.

This document will introduce technical specifications of S3602C (10MHz - 43.5GHz).

Definitions Instrument specifications listed in this datasheet applies to all different configurations S3602 VNA unless options are clearly noted.

Specification (Spec.)

Specifications describe the performance of parameters within the warranty of the instrument. Product specifications applies under the following conditions:

90 min warming up

Environmental temperature of 25℃ (± 5℃) with less than 1℃ deviation from the calibration temperature

Specifications include measurement uncertainties

Data in this document are Spec. unless otherwise noted.

Typical (typ.)

Typical data is not guaranteed by instrument warranty. It describes additional product performance information that 80 percent of the units exhibit. Typical data only valid at 25℃. Typical performance does not include measurement uncertainty.

Nominal(nom.)

Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty.

Calibration Kit and Ecal Modules Corrected system in this document is calibrated with following calibration kit:

SAV31123A 2.4mm Mechanical Calibration Kit

SAV20404 Ecal kit (10MHz - 50GHz, 2 port)

Page 8: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

8

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2. Specifications

2.1. Frequency

Frequency Range S3602C: 10MHz - 43.5GHz

Frequency Resolution 1Hz

Frequency Accuracy ±1×10-7(23℃±3℃)

2.2. Test Port Specification

2.2.1. Maximum Output Power 2-port configuration (Standard), signal source

Specification

Frequency

Port 1

Port 2 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz ≥-1dBm ≥+13dBm ≥+13dBm

0.05GHz - 4GHz ≥0dBm ≥+7dBm ≥+14dBm

4GHz - 13.5GHz ≥+8dBm ≥+11dBm

13.5GHz - 40GHz ≥+9.5dBm ≥+11dBm

40GHz -43.5GHz ≥+9.5dBm ≥+9dBm

Typical

Frequency

Port 1

Port 2 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz - ≥+14dBm ≥+16dBm

0.05GHz - 4GHz - ≥+9dBm ≥+15dBm

4GHz - 13.5GHz ≥+10dBm ≥+13dBm

13.5GHz - 40GHz ≥+13dBm ≥+12dBm

40GHz -43.5GHz ≥+10dBm ≥+11dBm

Page 9: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

9

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2-port configuration (Option 201), signal source

Specification

Frequency

Port 1

Port 2 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz ≥-2dBm ≥+12dBm ≥+13dBm

0.05GHz - 4GHz ≥-1dBm ≥+7dBm ≥+13dBm

4GHz - 13.5GHz ≥+7dBm ≥+10dBm

13.5GHz - 40GHz ≥+7dBm ≥+10.5dBm

40GHz -43.5GHz ≥+7dBm ≥+8dBm

Typical

Frequency

Port 1

Port 2 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz - ≥+13dBm ≥+15dBm

0.05GHz - 4GHz - ≥+8dBm ≥+14dBm

4GHz - 13.5GHz ≥+9dBm ≥+12dBm

13.5GHz - 40GHz ≥+12dBm ≥+12dBm

40GHz -43.5GHz ≥+9dBm ≥+10dBm

Page 10: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

10

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

4-port configuration(Option 400), 2 sources

Specification

Frequency

Port 1,3 Port 2, 4

Filtering mode (dBm) High-power mode

(dBm) (dBm)

10MHz - 50MHz ≥-1dBm ≥+13dBm ≥+13dBm

0.05GHz - 4GHz ≥0dBm ≥+7dBm ≥+14dBm

4GHz - 13.5GHz ≥+8dBm ≥+11dBm

13.5GHz - 40GHz ≥+9.5dBm ≥+11dBm

40GHz -43.5GHz ≥+9.5dBm ≥+9dBm

Typical

Frequency

Port 1,3

Port 2, 4 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz - ≥+14dBm ≥+16dBm

0.05GHz - 4GHz - ≥+9dBm ≥+15dBm

4GHz - 13.5GHz ≥+10dBm ≥+13dBm

13.5GHz - 40GHz ≥+13dBm ≥+12dBm

40GHz -43.5GHz ≥+10dBm ≥+11dBm

Page 11: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

11

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

4-port configuration(Option 401, Option 402), 2 sources

Specification

Frequency

Port 1,3

Port 2 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz ≥-2dBm ≥+12dBm ≥+13dBm

0.05GHz - 4GHz ≥-1dBm ≥+7dBm ≥+13dBm

4GHz - 13.5GHz ≥+7dBm ≥+10dBm

13.5GHz - 40GHz ≥+7dBm ≥+10.5dBm

40GHz -43.5GHz ≥+7dBm ≥+8dBm

Typical

Frequency

Port 1,3

Port 2, 4 (dBm) Filtering mode (dBm) High-power mode (dBm)

10MHz - 50MHz - ≥+13dBm ≥+15dBm

0.05GHz - 4GHz - ≥+8dBm ≥+14dBm

4GHz - 13.5GHz ≥+9dBm ≥+12dBm

13.5GHz - 40GHz ≥+12dBm ≥+12dBm

40GHz -43.5GHz ≥+9dBm ≥+10dBm

2.2.2. Output Power Setting Range

Standard/Option 400 -25dBm - +20dBm

With Attenuator (Option 201,401) -85dBm - +20dBm

2.2.3. Minimum Stable Output Power Standard/Option 400 -25dBm (Typ.)

With Attenuator (Option 201,401) -85dBm (Typ.)

2.2.4. Power Resolution

Power Resolution 0.01dB

2.2.5. Temperature Stability

Temperature Stability 0.06dB/℃

Page 12: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

12

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2.2.6. Power Accuracy

10MHz≤f≤13.5GHz ±1.5dB

13.5GHz<f≤40GHz ±2.0dB

40GHz<f≤43.5GHz ±3.0dB

2.2.7. Port Damage Level

Damage Level +27dBm, 30VDC

2.2.8. Power Sweep Range

Frequency Specification(dB) Typical

10MHz - 500MHz ≥+35dB ≥+38dB

0.5GHz - 4GHz ≥+30dB ≥+33dB

4GHz - 13.5GHz ≥+31dB ≥+34dB

13.5GHz - 40GHz ≥+33dB ≥+37dB

40GHz - 43.5GHz ≥+30dB ≥+34dB

2.2.9. 1dB Compression Point

Frequency range Figure(dBm)

10MHz - 43.5GHz ≥+10dBm (typ.)

2.2.10. Power Linearity

Power Linearity (23℃±3℃) ±2.0dB

2.2.11. Port Harmonics Suppression 2-port configuration (Standard, Option 201)

Frequency Figure(dBc)

Port 1 Harmonic Suppression

0.01GHz - 4GHz ≤-50dBc

4GHz - 13.5GHz ≤-60dBc

13.5GHz - 43.5GHz ≤-60dBc

Port 2 Harmonic Suppression

0.01GHz - 4GHz ≤-13dBc ( ≤ -15dBc typ.)

4GHz - 13.5GHz ≤-21dBc

13.5GHz - 43.5GHz ≤-60dBc

Page 13: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

13

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

4-port configuration (Option 400, Option 401)

Frequency Figure(dBc)

Port 1,3 Harmonic Suppression

0.01GHz - 4GHz ≤-50dBc

4GHz - 13.5GHz ≤-60dBc

13.5GHz - 43.5GHz ≤-60dBc

Port 2,4 Harmonic Suppression

0.01GHz - 4GHz ≤-13dBc ( ≤ -15dBc typ.)

4GHz - 13.5GHz ≤-21dBc

13.5GHz - 43.5GHz ≤-60dBc

2.3. Network Specifications

2.3.1. System Dynamic Range

IF bandwidth = 1Hz

Averaging factor = 8

Specification(dB) Typical(dB)

10MHz ≤ f ≤ 500MHz ≥90dB ≥105dB

500MHz < f ≤ 1GHz ≥110dB ≥117dB

1GHz < f ≤ 13.5GHz ≥122dB ≥133dB

13.5GHz < f ≤ 26.5GHz ≥120dB ≥126dB

26.5GHz < f ≤ 35GHz ≥115dB ≥120dB

35GHz < f ≤ 43.5GHz ≥112dB ≥116dB

2.3.2. Phase Noise Frequency offset 1kHz

Frequency Phase Noise Frequency Phase Noise

10MHz -124dBc/Hz 4GHz -99dBc/Hz

20MHz -123dBc/Hz 8GHz -93dBc/Hz

30MHz -126dBc/Hz 10GHz -89dBc/Hz

40MHz -122dBc/Hz 16GHz -87dBc/Hz

50MHz -118dBc/Hz 20GHz -83dBc/Hz

100MHz -112dBc/Hz 26.5GHz -81dBc/Hz

500MHz -117dBc/Hz 32GHz -81dBc/Hz

1GHz -111dBc/Hz 40GHz -77dBc/Hz

Page 14: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

14

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

Frequency Phase Noise Frequency Phase Noise

2GHz -105dBc/Hz

2.3.3. Noise Floor

Frequency Noise Floor

10MHz - 50MHz ≤-78dBm

50MHz – 500MHz ≤-83dBm

500MHz – 1GHz ≤-103dBm

1GHz - 4GHz ≤-115dBm

4GHz - 13.5GHz ≤-115dBm

13.5GHz - 26.5GHz ≤-113dBm

26.5GHz - 35GHz ≤-108dBm

35GHz - 40GHz ≤-105dBm

40GHz - 43.5GHz ≤-103dBm

2.3.4. Corrected System Performance Measurement environmental temperature 23° ±3 °C, with < 1 °C deviation from calibration temperature.

Following test cables are used in this test:

FE0BN0BM025.0 2.4mm Test Cable (Male DUT end) Applicable for Whole-Machine Measurement

FE0BN0BL025.0 2.4mm Test Cable (Female DUT end) Applicable for Whole-Machine Measurement

Page 15: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

15

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

Mechanical Calibration Kit SAV 31123A

Frequency Specification

Effective Directivity

0.01GHz - 13.5GHz ≥+50dB

13.5GHz - 40GHz ≥+45dB

40GHz - 43.5GHz ≥+42dB

Effective Source Match

10MHz≤f≤2GHz ≥+41dB

2GHz<f≤13.5GHz ≥+33dB

13.5GHz<f≤40GHz ≥+30dB

40GHz<f≤43.5GHz ≥+32dB

Effective Load Match

0.01GHz - 13.5GHz ≥+50dB

13.5GHz - 40GHz ≥+50dB

40GHz - 43.5GHz ≥+45dB

Reflection Tracking

0.01GHz - 13.5GHz ±0.01dB

13.5GHz - 40GHz ±0.01dB

40GHz - 43.5GHz ±0.015dB

Transmission Tracking

0.01GHz - 13.5GHz ±0.015dB

13.5GHz - 40GHz ±0.03dB

40GHz - 43.5GHz ±0.03dB

E-Cal Kit SAV 20404 (2-port)

Spec.

Frequency Range

10MHz - 45MHz 45MHz - 2GHz 2GHz - 10GHz 10GHz -20GHz 20GHz - 40GHz 40GHz - 43.5GHz

Effective Directivity ≥45dB ≥45dB ≥43dB ≥40dB ≥37dB ≥33dB

Effective Source Match ≥37dB ≥37dB ≥34dB ≥31dB ≥30dB ≥32dB

Effective Load Match ≥39dB ≥39dB ≥36dB ≥35dB ≥33dB ≥32dB

Reflection Tracking ±0.06dB ±0.06dB ±0.08dB ±0.09dB ±0.12dB ±0.15dB

Transmission Tracking ±0.07dB ±0.07dB ±0.09dB ±0.12dB ±0.16dB ±0.20dB

Page 16: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

16

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2.3.5. Trace Noise

Frequency range Figure(dB rms)

Trace Noise Magnitude 1KHz IF bandwidth

10MHz - 50MHz ≤ 0.006

50MHz - 500MHz ≤ 0.002

0.5GHz - 13.5GHz ≤ 0.001

13.5GHz - 26.5GHz ≤ 0.0009

26.5GHz - 43.5GHz ≤ 0.004

Frequency range Figure(deg rms)

Trace Noise Phase 1KHz IF bandwidth

10MHz - 50MHz ≤ 0.04

50MHz - 500MHz ≤ 0.01

0.5GHz - 13.5GHz ≤ 0.005

13.5GHz - 26.5GHz ≤ 0.02

26.5GHz - 43.5GHz ≤ 0.03

2.4. Pulse Specifications

Pulse Width Setting Range 20ns - 60s

Pulse transition time (10% - 90%) 20ns

Pulse off ratio

Frequency range Figure(dB)

0.01GHz-4GHz 64dB

4GHz-13.5GHz 80dB

13.5GHz-43.5GHz 80dB

Page 17: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

17

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2.5. General

IF Bandwidth 1Hz - 5MHz

Max. Sweep Point per Trace 32001

Sweep Type Linear, Log, Power, CW, Segment, Phase

Trace Display Format Log magnitude, linear magnitude, SWR , phase , group delay, real and

imaginary , smith chart, polar

Magnitude Display Resolution 0.001dB/div

Phase display Resolution 0.01°/div

Reference Level Magnitude -500 ~ +500dB

Input Reference Phase Range -500 ~ +500°

Port Connector Type 2.4mm (M),50 Ω impedance

Measurement of Ports 2 port Standard;4-port with option 400

Peripheral Interface

8 x USB type B, 1 x USB type A: for USB device, printer etc

GPIB: programming control interface

VGA: external display interface

LAN: network interface, programming control interface

Operating System Windows 7

Storage Capability 160G SSD

Screen 12.1 inch high resolution touch screen

Dimension (LxHxW) 516mm x 280mm x 690mm (W x H x D)

Power 220V±10%, 50Hz - 60Hz

Operating Temperature 0℃ - 50℃

Storage Temperature -30℃ - 70℃

Maximum Power Consumption 500W

Maximum Weight 47kg

Page 18: S3602C Vector Network Analyzer Datasheet - Saluki Tec · 2017-09-21 · S3602C vector network analyzer (10MHz - 43.5GHz). Options of the S3602C vector network analyzer in addition

18

Tel: 886.2.2175 2930 Email: [email protected]

www.salukitec.com

2.6. Compliant

2.6.1. CE

EMC

Complies with the requirements of the EC EMC directive 2014/30/EU with amendments.

Test Standards:

EN 61326-1:2013

EN 61000-3-2:2014

EN 61000-3-3:2013

Safety

Complies with EC LVD Directive 2014/35/EU with amendment.

Test Standard

EN61010-1:2010

2.6.2. ISO

Manufacturing

This instrument is manufactured in an ISO-9001 registered facility

- End of Document -