s200m dc, mcb for dc application top performance with high ... · use in direct current circuits |...
TRANSCRIPT
S200M DC, MCB for DC applicationTop performance with high breaking capacity
The MCB for Extra performanceThe S200M DC range can be fitted with auxiliary and signal contact, remote control mechanism, shunt trip and under voltage release.
International ApprovalsThe result of an enormous performance, The S200M DC has got international approval from VDE
Clearly BetterActuation and indication of the contact position is performed in a clear and unambiguous manner. The position of the toggle and the red/green display leave no doubt about the present switching position thus providing always reliable information in the event of an error.
Miniature Circuit Breaker S200M DCTechnical features
Captive screws: don’t loose what’simportant for you.
Quick identification thanks to laser printed EAN marking.
Whatever your application need is – applicable with a wide range of accessories.
Real contact position indication
Twin terminal for separate feeding of busbar and conductor
IP20 - finger safety.
Save your time – all important data available right away.
Easy product name, easy identification, easy life.
VDE Approval printed on the dome
Visibly safeWith the permanent magnets used for arc extinguishing, it is necessary to take into account, the polarity for successfully extinguishing the arc.Bold and reliable Laser marking of the polarity on the device near the terminals allows easy and safe installation of these MCBs.
Connecting to more powerThe optimized connection terminal of the S200M DC enables connection with wires up to 35 mm2 and busbars of 10 mm2.
2 S200M DC Flyer | Technical features
Performance in actionS200 M DC MCB in System pro Mcompact range impresses with itsperformance range, approvals and highinbuilt short circuit breaking capacityin DC applications. S200 M DC MCBscan be used in 1-pole version at 220VDC and in 2-pole version at 440V DC.
Miniature Circuit Breaker S200M DCTechnical Data
Dimensions and Weight
Mounting dimensions acc. To DIN 43880 1
Pole dimensions ( H X D X W ) 85 X 69 X 17.5
Pole weight approx. 125g
Installation
Terminal Fail safe bi-directional cylinder - lift terminal
Cross-section of conductors (top / bottom) Solid, Stranded: 35 mm2 / 35 mm2
Flexible 25 mm2 / 25 mm2
Cross-section of busbars (top / bottom) 10 mm2 / 10 mm2
Torque 2.8 Nm
Screwdriver No. 2 Pozidrive
Mounting On DIN rail 35 mm acc. to EN 60715 by fast clip
Mounting position any
Supply Please note polarity of the device
Combination with Auxiliary elements
Auxiliary contact Yes
Signal contact Yes
Shunt trip Yes
Undervoltage release Yes
Motor operating device Yes
Mechanical Data
Housing Insulation group I, RAL 7035
Toggle Insulation group II, black ,sealable
Contact position indication Marking on toggle (1 ON / 0 OFF), Real CPI (red ON / green OFF)
Protection degree acc. to DIN En 60529 IP20, IP40 in enclosure with cover
Mechanical endurance 20,000 ops
Shock resistance acc. to IEC/EN 60068-2-27 25g - 2 shocks - 13ms
Vibration resistance acc. to IEC/EN 60068-2-6 5g - 20 cycles at 5...150...5 Hz at 0.8 InAmbient temperature -25 …..+55 C
Storage temperature -40 …..+70 C
Data according to IEC 60947-2
Rated operational Voltage Un 1P : 220 V DC 2P : 440V DC
Maximum Power frequency recovery Voltage, Umax 1P : 250V DC 2P : 500V DC
Min Operating Voltage 12 V DC
Rated Ultimate short-circuit breaking Capacity, Icu 10 kA
Rated Service short-circuit breaking Capacity, Ics 10 kA
Rated impluse withstand voltage Uimp (1.2/50µs) 4 kV (test voltage 6.2 kV at sea level; 5 kV at 2,000 m)
Dielectric test voltage 2 kV (1 min)
Reference temperature for tripping characteristics 55 oC
Electrical endurance 1,500 ops
General Data
Standards IEC 60947-2
Approvals VDE
Poles 1P, 2P
Rated Curent 1.6A - 63A
Tripping Characteristics Curve C
Overvoltage category III
Pollution degree 2
Technical Data | S200M DC Flyer 3
Miniature Circuit Breaker S200M DCOrdering Codes
S202M-C1,6DC 2CDS272064R0974 1.6 6
S202M-C2DC 2CDS272064R0024 2 6
S202M-C3DC 2CDS272064R0034 3 6
S202M-C4DC 2CDS272064R0044 4 6
S202M-C6DC 2CDS272064R0064 6 6
S202M-C10DC 2CDS272064R0104 10 6
S202M-C16DC 2CDS272064R0164 16 6
S202M-C20DC 2CDS272064R0204 20 6
S202M-C25DC 2CDS272064R0254 25 6
S202M-C32DC 2CDS272064R0324 32 6
S202M-C40DC 2CDS272064R0404 40 6
S202M-C50DC 2CDS272064R0504 50 6
S202M-C63DC 2CDS272064R0634 63 6
S201M-C1,6DC 2CDS271064R0974 1.6 12
S201M-C2DC 2CDS271064R0024 2 12
S201M-C3DC 2CDS271064R0034 3 12
S201M-C4DC 2CDS271064R0044 4 12
S201M-C6DC 2CDS271064R0064 6 12
S201M-C10DC 2CDS271064R0104 10 12
S201M-C16DC 2CDS271064R0164 16 12
S201M-C20DC 2CDS271064R0204 20 12
S201M-C25DC 2CDS271064R0254 25 12
S201M-C32DC 2CDS271064R0324 32 12
S201M-C40DC 2CDS271064R0404 40 12
S201M-C50DC 2CDS271064R0504 50 12
S201M-C63DC 2CDS271064R0634 63 12
Single pole
Double Pole
Description Ordering CodeCurrent Rating
(A)Pack Unit
(Pc)
Easy identificationABB uses clever product designation. All the important technical details can be found on the device in a very simple and easily readable way.
Product family S200 Tripping Characteristics
Breaking capacity 10kA
No of poles Rated current
DC series
S20 1 M C 16DC -
4 S200M DC Flyer | Ordering CodesUse in direct current circuits | S200M DC Flyer 5
– S200M DC MCBs can be used in the one-pole version at 220 V DC and in the 2-pole or 4-pole version with series connection of two poles up to 440 V DC.
Miniature Circuit Breaker S200M DCUse in direct current circuits
– S200M DC MCBs have, in the area of arc chutes, permanent magnets. It is therefore necessary to take into account the polarity during the installation process.Incorrect polarities may cause damage to the MCB.
C 40S 202 M
DC
+
+
B365C 123456
Icu 10kA440VIEC60947-2
C 40S 202 M
DC
+
+
B365C 123456
Icu 10kA440VIEC60947-2
Supply and load connections
S 201 MC 40DC
+
B365C 123456
Icu 10kA220VIEC60947-2
S 201 MC 40DC
+
B365C 123456
Icu 10kA220VIEC60947-2
+ Load –
– Load + – Load +
+ Load –
Example for permissible voltages between the conductors depending on the number of poles and circuit layout:
voltage Un
between conductors
220 V- 440 V- 440 V- 440 V-
voltage Un
between conductor and earth
220 V- 220 V- 440 V- 220 V-
MCB 1-pole S201M DC
2-pole S202M DC
2-pole S202M DC
2-pole S202M DC
supply from below
supply from above
–
+
–
+ –
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
– –
+-
+ +
-DC supply DC supply
When supply is given at lower terminals When supply is given at upper terminals
DC supply DC supply
+
Use in direct current circuits | S200M DC Flyer 5
– S200M DC MCBs can be used in the one-pole version at 220 V DC and in the 2-pole or 4-pole version with series connection of two poles up to 440 V DC.
Miniature Circuit Breaker S200M DCUse in direct current circuits
– S200M DC MCBs have, in the area of arc chutes, permanent magnets. It is therefore necessary to take into account the polarity during the installation process.Incorrect polarities may cause damage to the MCB.
C 40S 202 M
DC
+
+
B365C 123456
Icu 10kA440VIEC60947-2
C 40S 202 M
DC
+
+
B365C 123456
Icu 10kA440VIEC60947-2
Supply and load connections
S 201 MC 40DC
+
B365C 123456
Icu 10kA220VIEC60947-2
S 201 MC 40DC
+
B365C 123456
Icu 10kA220VIEC60947-2
+ Load –
– Load + – Load +
+ Load –
Example for permissible voltages between the conductors depending on the number of poles and circuit layout:
voltage Un
between conductors
220 V- 440 V- 440 V- 440 V-
voltage Un
between conductor and earth
220 V- 220 V- 440 V- 220 V-
MCB 1-pole S201M DC
2-pole S202M DC
2-pole S202M DC
2-pole S202M DC
supply from below
supply from above
–
+
–
+ –
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
– –
+-
+ +
-DC supply DC supply
When supply is given at lower terminals When supply is given at upper terminals
DC supply DC supply
+
Accessory overview
Dimensional drawing
Miniature Circuit Breaker S200M DCAccessories and dimensional drawings
H Auxiliary contact S2C-H6R
H-R Auxiliary contact S2C-H6-…R
S/H Signal/Auxiliary contact S2C-S/H6R
S/H (H) Signal/Auxiliary contact used as auxiliary
contact
S2C-S/H6R
ST Shunt trip S2C-A…
UR Undervoltage release S2C-UA
ST-L Shunt trip to be mounted on the left S2C-A…L
H-L Auxiliary contact to be mounted on the left S2C-H…L
H-BF Auxiliary contact for bottom fi tting (1 for
each pole of MCB)
S2C-H01/
S2C-H10
BP Mechanical tripping device S2C-BP
Description Order details Ordering Code
Auxiliary Contact, 1CO (Right side) S2C-H6R 2CDS200912R0001
Auxiliary Contact, 1NO / 1NC (Right side) S2C-H6-11R 2CDS200946R0001
Auxiliary Contact, 2NO (Right side) S2C-H6-20R 2CDS200946R0002
Auxiliary Contact, 2NC (Right side) S2C-H6-02R 2CDS200946R0003
Signal contact / Auxiliary switch, 1CO
(Right side)
S2C-S/H6R 2CDS200922R0001
Auxiliary Contact, 1NO / 1NC (Left side) S2C-H11L 2CDS200936R0001
Auxiliary Contact, 2NO (Left side) S2C-H20L 2CDS200936R0002
Auxiliary Contact, 2NC (Left side) S2C-H02L 2CDS200936R0003
Description Order details Ordering Code
Bottom fi tting Aux contact, 1NC S2C-H01 2CDS200970R0001
Bottom fi tting Aux contact, 1NO S2C-H10 2CDS200970R0002
Shunt Trip, 12...60V AC/DC S2C-A1 2CDS200909R0001
Shunt Trip, 110…415V AC,
110…250 DC
S2C-A2 2CDS200909R0002
Undervoltage Release, 12V DC S2C-UA 12 DC 2CSS200911R0001
Undervoltage Release, 24V DC S2C-UA 24 DC 2CSS200911R0007
Undervoltage Release, 48V DC S2C-UA 48 DC 2CSS200911R0008
Undervoltage Release, 110V DC S2C-UA 110 DC 2CSS200911R0009
Undervoltage Release, 230V DC S2C-UA 230 DC 2CSS200911R0010
6 S200M DC Flyer | Accessories and dimensional drawings
Railways Uninterruptible power supply (UPS)Storage batteries system
Industrial machineries
Miniature Circuit Breaker S200M DCThe best solution for DC applications
DC motor systems Air Insulated switchgear
The best solution for DC applications | S200M DC Flyer 7
ABB India Helpline: Technical Telephone support for customers and channel partners.� Toll Free: (BSNL) +91 1800 420 07 07email : [email protected]
www.abb.com/lowvoltage
Contact us©
copyright 2015 A
BB
. All rights reserved
LP/S
200M_D
C_B
rochure/2015_20_08/001