s pumps, range 58 - grundfos usa - pumps and pump ... s pumps, range 58 7 pump nameplate fig. 2 pump...

56
GRUNDFOS PRODUCT GUIDE S pumps, range 58 34 to 42 hp 60 Hz ANSI

Upload: lamtruc

Post on 03-May-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

GRUNDFOS PRODUCT GUIDE

S pumps, range 58

34 to 42 hp60 Hz ANSI

Contents

2

IntroductionIntroduction 3Applications 3Main constructional features 4

Performance rangePerformance range, S pumps 5Performance range, S pumps, range 58 5

IdentificationType key 6Pump nameplate 7FM approval plate 7

Selection of productOrdering a pump 8

Product rangeStandard range 9Explosion-proof range 11Explosion proof range with stainless steel impeller 12

VariantsList of variants 13

ConstructionSectional drawings, motors 14Sectional drawings, pumps 18Components and material specification 24

Product descriptionFeatures 25Operating conditions 26Motor range 26Explosion-proof pumps 27Pump controllers 27Wiring diagrams 28

Curve charts/Technical dataHow to read the curve charts 29Curve conditions 30Performance tests 30Certificates 30Witness test 30

Performance curvesTechnical dataS 58 extra-low pressure, 6-pole 32S 58 low pressure, 4-pole 34S 58 low pressure, 4-pole 36S 58 medium pressure, 4-pole 38S 58 high pressure, 4-pole 40

AccessoriesAccessories (for installation) 42Other accessories 43

DimensionsInstallation on auto coupling 44Installation on ring stand 48Dry pit, vertical installation 50Dry pit, horisontal installation 52

Further product documentationWebCAPS 54WinCAPS 55

S pumps, range 58Introduction

IntroductionThis product guide deals with Grundfos heavy-duty sewage pumps called S pumps, range 58.

This product guide was printed in July 2010. A newer version might be available from Grundfos WebCAPS. Go to WebCAPS Literature to locate and download the latest version - or insert the link below directly in your browser to get to the download page:

http://net.grundfos.com/Appl/WebCAPS/

Using the PDF version of this data booklet offers extra features to the booklet. Double-clicking a product number listed in the data booklet will open an internet browser window displaying all technical information available on the product.

Fig. 1 S pump, range 58

The S pumps, range 58, are a range of free-flow (SuperVortex) and channel impeller pumps specifically designed for pumping sewage and wastewater in a wide range of municipal, private and industrial applica-tions.

The pumps are made of resistant materials, such as cast iron and stainless steel. These materials ensure a proper operation.

The pumps are fitted with motors from 34 hp up to 45 hp (25 kW up to 32 kW). The motors are 4-pole motors.

The free passage in the pumps is 3, 4 or 4.5" (80, 100 or 115 mm).

The pumps are available for:

• submerged installation on auto-coupling system• submerged installation, free-standing• dry-pit installation, vertical• dry-pit installation, horizontal.

ApplicationsThe S pumps, range 58, are designed for applications, such as:

• raw water intake• wastewater treatment plants• municipal pumping stations • public buildings • residential housing• blocks of apartments• industries• parking garages • underground car parks • car wash areas • restaurants and hotels. The pumps are suitable for both temporary and perma-nent installation. The lifting bracket fitted on the pumps facilitates easy transportation to as well as installation at the installation site.

GrA

7835

3

Introduction S pumps, range 58

4

Main constructional features• leak-proof connections via the Grundfos SmartSeal

gasket system• double mechanical shaft seal system for reliable

sealing between pumped liquid and motor• watertight cable entry of corrosion-resistant polya-

mide or cast iron for FM approved pumps• moisture switch for continuous monitoring of motor

housing and automatic cut-off of power in case liq-uid penetrates

• self-cleaning channel impeller with long vanes re-ducing the risk of jamming or clogging, or SuperVor-tex impeller with high pumping efficency and less downtime

• SmartTrim system allowing easy adjustment of im-peller clearance and maintaining maximum pump efficiency over pump lifetime

• motor in insulation class H (356 °F (180 °C)), enclo-sure class IP68 with three thermal sensors in stator windings

• seal condition monitoring via water-in-oil sensor (optional)

• explosion-proof motors for applications involving high risk of explosion

• stainless steel versions for use in corrosive or ag-gressive liquids:Q: stainless steel impeller, cast iron pump and mo-tor housing.

S pumps, range 58

5

Performance range

Performance range, S pumps

Performance range, S pumps, range 58

TM04

655

7 06

10TM

04 6

607

0610

100 150 200 300 400 500 8001000 1500 2000 3000 5000 10000 15000

Q [US GPM]

6

8

10

15

20

30

40

60

80

100

150

200

300

[ft]H

1010 20 30 40 50 60 7080 100100 200 300 400 600 800Q [l/s]

2

3

4

5

6

8

1010

20

30

40

50

60

80

[m]H

60 Hz

50

54

58

62

66

70

20000

0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400

Q [US GPM]

15

20

25

30

40

50

60

80

100

120

150

200

[ft]H

0 50 100 150 200 250 Q [l/s]

5

6

7

8

9

1010

20

30

40

50

60

[m]H

60 Hz

S PumpsRange 58

S1.40.A50

S2.40.A80S1.45.A80

S1.30.A50

6

S pumps, range 58Identification

Type keyCode Example S 1 .30 .A50 .420 4 .58H .C .307 .G .N .D

SST

Pump type:Grundfos sewage and wastewater pumpMulti-channel impeller pump installed in a column pipe

1V

Impeller type:Single-channel impellerSuperVortex (free-flow) impeller

Pump passage:Maximum solids size = Code number from type designation/10 [inch]

A50

Pump discharge:Nominal diameter of pump discharge port = Code number from type designation/10 [inch]5"

Output power, P2:P2 = Code number from type designation/10 [hp]

4Number of poles: 4-pole motor

58H58M58L

Pump range / Pressure version:High pressureMedium pressure Low pressure

SCDH

Installation:Submersible installation without cooling jacketSubmersible installation with cooling jacketDry installation, verticalDry installation, horizontal.

Actual impeller diameter:[mm]

GMaterial code for impeller, pump and motor housing:Impeller, pump housing and motor housing: Cast iron

NEx

Pump version:Non-explosion-proof pumpExplosion-proof pump

BCD

Sensor version:B = S pump with built-in SM 111 module. PTC sensors are connected directly to IO 111 or other PTC relay.C = Not in useD = S pump without built-in SM 111 module.

Z Custom-built products

Identification S pumps, range 58

Pump nameplate

Fig. 2 Pump nameplate

FM approval plate

Fig. 3 Ex approval plate

The approval plate gives the following details:

TM04

649

4 12

10

Pos. Description1 Type designation

2 SAP code

3 Serial number

4 Maximum ambient temperature

5 Maximum head

6 Maximum flow

7 Maximum installation depth

8 Enclosure class

9 Number of phases

10 Frequency

11 Rated speed

12 Voltage/current, delta connection

13 Voltage/current, star connection

14 Power input/output

15 Service factor

16 Power factor

17 Insulation class

18 Production code, year/week

19 Weight of the pump

20 Model

2

1

3579

1013141618

20468

1112

1719

15

TM04

649

5 02

10

FM symbol

II Equipment group (II = non-mining)

2 Equipment category (high protection)

G Type of explosive atmosphere

CE CE mark

1180 Number of quality assurance notified body

Ex Motor explosion-proof according to FM standard

b Control of ignition sources

c Constructional safety

d Motor withstands explosion pressure

IIB Gas group (Ethylene)

T3C Maximum surface temperature of the motor is 320 °F (160 °C)

T4 Maximum surface temperature of the motor is 275 °F (135 °C)

Gb Equipment protection level, zone 1

Baseefa Certificate number

FM Certificate number

FM

7

S pumps, range 58

8

Selection of product

Ordering a pumpWhen ordering an S pump, range 58, you need to take the following four aspects into consideration.

1. Pump2. Custom-built variation (option)3. Accessories4. Controller.

PumpUse the selection tool in WebCAPS to find the best suited pump for your application or use the section Product range on page 9 and the section Type key on page 6 to identify the pump that best fulfils your needs. The list below is a detailed description of the product you get if you order the following pump:

• Pump as specified in the type key• 50 ft (15 m) cable• Paint: Graphic grey, NCS S8005-R80B, thickness

150 μ • Three thermal switches (Klixon), one in each phase,

or three thermal sensors (PTC)• One moisture switch below the motor top cover (two

moisture switches below the motor top cover on explosion-proof versions)

• ANSI-HI centrifugal pump, test 1.6-2000 Acceptance level B.

See section Performance curves Technical data for selection of a standard pump.

Note: Product specific data for the pump can also be seen in WebCAPS using the product number 97632138.

Custom-built variantsThe S pumps can be customised to meet individual requirements. Many pump features and options are available for customisation, e.g. explosion-proof versions, various cable lengths or special materials.

Variants can be seen in section List of variants on page 13. For requirements or designs not included in the list, contact Grundfos.

AccessoriesDepending on the installation type, you may need to order accessories. See section Accessories on page 42 for selection of the correct accessories.

Note: Ordered accessories are not fitted from factory.

ControllerThe following controllers are available:

Grundfos Dedicated Controls (DC).Pump Product noS1.30.A50.420.4.58H.C.307.G.N.D 97632138

S pumps, range 58Product range

Standard range

* Wi hout hose connection.** Installation type S and C pumps with discharge flange size 10" (DN 250) and higher are supplied with guide claw mounted on the flange.*** The horizontal base stand is included in the pump product number.

Pump type Pump

Accessories

*** Horizontal base stand

To be ordered separatelyVertical base

stand** Auto-coupling

system* Ring stand for

portable useS1.30.A50.340.4.58H.S.290.G.N.D 97632133 - - 97626242 96856262S1.30.A50.340.4.58H.C.290.G.N.D 97632134 - - 97626242 96856262S1.30.A50.340.4.58H.D.290.G.N.D 97632135 - 96308238 - -S1.30.A50.340.4.58H.H.290.G.N.D 97632136 96782930 - - -S1.30.A50.420.4.58H.S.307.G.N.D 97632137 - - 97626242 96856262S1.30.A50.420.4.58H.C.307.G.N.D 97632138 - - 97626242 96856262S1.30.A50.420.4.58H.D.307.G.N.D 97632139 - 96308238 - -S1.30.A50.420.4.58H.H.307.G.N.D 97632140 96782930 - - -S1.45.A80.420.4.58L.S.264.G.N.D 97632141 - - 97506541 96790704S1.45.A80.420.4.58L.C.264.G.N.D 97632142 - - 97506541 96790704S1.45.A80.420.4.58L.D.264.G.N.D 97632143 - 96856263 - -S1.45.A80.420.4.58L.H.264.G.N.D 97632144 96856265 - - -S1.40.A50.420.4.58M.S.278.G.N.D 97632145 - - 97626242 96856262S1.40.A50.420.4.58M.C.278.G.N.D 97632146 - - 97626242 96856262S1.40.A50.420.4.58M.D.278.G.N.D 97632147 - 96094523 - -S1.40.A50.420.4.58M.H.278.G.N.D 97632148 96784437 - - -S2.40.A80.420.4.58L.S.227.G.N.D 97632149 - - 97506541 96790704S2.40.A80.420.4.58L.C.227.G.N.D 97632150 - - 97506541 96790704S2.40.A80.420.4.58L.D.227.G.N.D 97632151 - 96856263 - -S2.40.A80.420.4.58L.H.227.G.N.D 97632152 96856265 - - -S2.40.A120.340.6.58E.S.295.G.N.D 97632153 - - 97510049 96856259S2.40.A120.340.6.58E.C.295.G.N.D 97632154 - - 97510049 96856259S2.40.A120.340.6.58E.D.295.G.N.D 97632155 - 96856263 - -S2.40.A120.340.6.58E.H.295.G.N.D 97632156 96856265 - - -

9

Product range S pumps, range 58

10

Standart range with stainless steel impeller

* Wi hout hose connection.** Installation type S and C pumps with discharge flange size 10" (DN 250) and higher are supplied with guide claw mounted on the flange.*** The horizontal base stand is included in the pump product number.

Pump type Pump

Accessories

*** Horizontal base stand

To be ordered separatelyVertical base

stand** Auto-coupling

system* Ring stand for

portable useS1.30.A50.340.4.58H.S.290.Q.N.D 97647810 - - 97626242 96856262S1.30.A50.340.4.58H.C.290.Q.N.D 97647811 - - 97626242 96856262S1.30.A50.340.4.58H.D.290.Q.N.D 97647812 - 96308238 - -S1.30.A50.340.4.58H.H.290.Q.N.D 97647813 96782930 - - -S1.30.A50.420.4.58H.S.307.Q.N.D 97647814 - - 97626242 96856262S1.30.A50.420.4.58H.C.307.Q.N.D 97647815 - - 97626242 96856262S1.30.A50.420.4.58H.D.307.Q.N.D 97647816 - 96308238 - -S1.30.A50.420.4.58H.H.307.Q.N.D 97647817 96782930 - - -S1.45.A80.420.4.58L.S.264.Q.N.D 97661423 - - 97506541 96790704S1.45.A80.420.4.58L.C.264.Q.N.D 97661424 - - 97506541 96790704S1.45.A80.420.4.58L.D.264.Q.N.D 97661425 - 96856263 - -S1.45.A80.420.4.58L.H.264.Q.N.D 97661427 96856265 - - -S1.40.A50.420.4.58M.S.278.Q.N.D 97647818 - - 97626242 96856262S1.40.A50.420.4.58M.C.278.Q.N.D 97647819 - - 97626242 96856262S1.40.A50.420.4.58M.D.278.Q.N.D 97647820 - 96094523 - -S1.40.A50.420.4.58M.H.278.Q.N.D 97647821 96784437 - - -S2.40.A80.420.4.58L.S.227.Q.N.D 97647822 - - 97506541 96790704S2.40.A80.420.4.58L.C.227.Q.N.D 97647823 - - 97506541 96790704S2.40.A80.420.4.58L.D.227.Q.N.D 97647824 - 96856263 - -S2.40.A80.420.4.58L.H.227.Q.N.D 97647825 96856265 - - -S2.40.A120.340.6.58E.S.295.Q.N.D 97647826 - - 97510049 96856259S2.40.A120.340.6.58E.C.295.Q.N.D 97647827 - - 97510049 96856259S2.40.A120.340.6.58E.D.295.Q.N.D 97647828 - 96856263 - -S2.40.A120.340.6.58E.H.295.Q.N.D 97647829 96856265 - - -

Product range S pumps, range 58

Explosion-proof range

* Wi hout hose connection.** Installation type S and C pumps with discharge flange size 10" (DN 250) and higher are supplied with guide claw mounted on the flange.*** The horizontal base stand is included in the pump product number.

Pump type Pump

AccessoriesTo be ordered separately

*** Horizontal base stand

Vertical base stand

** Auto-coupling system

* Ring stand for portable use

S1.30.A50.340.4.58H.S.290.G.Ex.D 97660672 - - 97626242 96856262S1.30.A50.340.4.58H.C.290.G.Ex.D 97660673 - - 97626242 96856262S1.30.A50.340.4.58H.D.290.G.Ex.D 97660674 - 96308238 - -S1.30.A50.340.4.58H.H.290.G.Ex.D 97660675 96782930 - - -S1.30.A50.420.4.58H.S.307.G.Ex.D 97660676 - - 97626242 96856262S1.30.A50.420.4.58H.C.307.G.Ex.D 97660677 - - 97626242 96856262S1.30.A50.420.4.58H.D.307.G.Ex.D 97660678 - 96308238 - -S1.30.A50.420.4.58H.H.307.G.Ex.D 97660679 96782930 - - -S1.45.A80.420.4.58L.S.264.G.Ex.D 97660680 - - 97506541 96790704S1.45.A80.420.4.58L.C.264.G.Ex.D 97660711 - - 97506541 96790704S1.45.A80.420.4.58L.D.264.G.Ex.D 97660712 - 96856263 - -S1.45.A80.420.4.58L.H.264.G.Ex.D 97660713 96856265 - - -S1.40.A50.420.4.58M.S.278.G.Ex.D 97660714 - - 97626242 96856262S1.40.A50.420.4.58M.C.278.G.Ex.D 97660715 - - 97626242 96856262S1.40.A50.420.4.58M.D.278.G.Ex.D 97660716 - 96094523 - -S1.40.A50.420.4.58M.H.278.G.Ex.D 97660717 96784437 - - -S2.40.A80.420.4.58L.S.227.G.Ex.D 97660718 - - 97506541 96790704S2.40.A80.420.4.58L.C.227.G.Ex.D 97660719 - - 97506541 96790704S2.40.A80.420.4.58L.D.227.G.Ex.D 97660720 - 96856263 - -S2.40.A80.420.4.58L.H.227.G.Ex.D 97660721 96856265 - - -S2.40.A120.340.6.58E.S.295.G.Ex.D 97660722 - - 97510049 96856259S2.40.A120.340.6.58E.C.295.G.Ex.D 97660723 - - 97510049 96856259S2.40.A120.340.6.58E.D.295.G.Ex.D 97660724 - 96856263 - -S2.40.A120.340.6.58E.H.295.G.Ex.D 97660725 96856265 - - -

11

Product range S pumps, range 58

12

Explosion proof range with stainless steel impeller

* Wi hout hose connection.** Installation type S and C pumps with discharge flange size 10" (DN 250) and higher are supplied with guide claw mounted on the flange.*** The horizontal base stand is included in the pump product number.

Pump type Pump

Accessories

*** Horizontal base stand

To be ordered separatelyVertical base

stand** Auto-coupling

system* Ring stand for

portable useS1.30.A50.340.4.58H.S.290.Q.Ex.D 97663643 - - 97626242 96856262S1.30.A50.340.4.58H.C.290.Q.Ex.D 97663644 - - 97626242 96856262S1.30.A50.340.4.58H.D.290.Q.Ex.D 97663645 - 96308238 - -S1.30.A50.340.4.58H.H.290.Q.Ex.D 97663646 96782930 - - -S1.30.A50.420.4.58H.S.307.Q.Ex.D 97663647 - - 97626242 96856262S1.30.A50.420.4.58H.C.307.Q.Ex.D 97663648 - - 97626242 96856262S1.30.A50.420.4.58H.D.307.Q.Ex.D 97663649 - 96308238 - -S1.30.A50.420.4.58H.H.307.Q.Ex.D 97663650 96782930 - - -S1.45.A80.420.4.58L.S.264.Q.Ex.D 97663691 - - 97506541 96790704S1.45.A80.420.4.58L.C.264.Q.Ex.D 97663692 - - 97506541 96790704S1.45.A80.420.4.58L.D.264.Q.Ex.D 97663693 - 96856263 - -S1.45.A80.420.4.58L.H.264.Q.Ex.D 97663694 96856265 - - -S1.40.A50.420.4.58M.S.278.Q.Ex.D 97663695 - - 97626242 96856262S1.40.A50.420.4.58M.C.278.Q.Ex.D 97663696 - - 97626242 96856262S1.40.A50.420.4.58M.D.278.Q.Ex.D 97663697 - 96094523 - -S1.40.A50.420.4.58M.H.278.Q.Ex.D 97663698 96784437 - - -S2.40.A80.420.4.58L.S.227.Q.Ex.D 97663699 - - 97506541 96790704S2.40.A80.420.4.58L.C.227.Q.Ex.D 97663700 - - 97506541 96790704S2.40.A80.420.4.58L.D.227.Q.Ex.D 97663701 - 96856263 - -S2.40.A80.420.4.58L.H.227.Q.Ex.D 97663702 96856265 - - -S2.40.A120.340.6.58E.S.295.Q.Ex.D 97663703 - - 97510049 96856259S2.40.A120.340.6.58E.C.295.Q.Ex.D 97663704 - - 97510049 96856259S2.40.A120.340.6.58E.D.295.Q.Ex.D 97663705 - 96856263 - -S2.40.A120.340.6.58E.H.295.Q.Ex.D 97663706 96856265 - - -

S pumps, range 58

13

Variants

List of variantsMotor

Various cable lengths82 ft (25 m)165 ft (50 m)

EMC power cables Screened power cables for variable speed drives

33 ft (10 m)50 ft (15 m)82 ft (25 m)165 ft (50 m)

Special motor Special voltagePTC thermistors in windingsSpecial oil Non-toxic Shell Ondina 917

Motor protectionPTC + moisture switch FPV1Klixon + moisture switch + WIO FPV2aPTC + moisture switch + WIO FPV2bKlixon + moisture switch + WIO + PT100 at lower and upper bearing FPV4aPTC + moisture switch + WIO + PT100 at lower and upper bearing FPV4b

MaterialsStainless steel lifting bracket AISI 316 Stainless steel impeller Variant QStainless steel impeller and pump housing Variant S Stainless steel Impeller, pump housing and motor housing Variant R

Tests

Test at specified duty on standard impeller curve

Trimmed impeller for specified duty test Additional test of entire QH curve (incl. report) 5-10 flows from pump performance curve

Different test standard Efficiency guaranteed by GrundfosISO 9906 grade 1 tolerancesISO 9906 grade 2 tolerances

Vibration test (incl. report) According to Grundfos factory quality standardPerformance test on dry test stand Not yet availableNPSHr test Not yet availableString test Contact GrundfosWitness test Contact Grundfos

MiscellaneousSpecial packaging Contact GrundfosSpecial nameplate Contact GrundfosOther variants Contact Grundfos

14

S pumps, range 58Construction

Sectional drawings, motors

Fig. 4 Non-explosion-proof motor without cooling jacket

TM04

230

6 23

08

Construction S pumps, range 58

Fig. 5 Non-explosion-proof motor with cooling jacket

TM04

230

7 23

08

15

Construction S pumps, range 58

16

Fig. 6 Explosion-proof motor without cooling jacket

TM04

230

8 23

08

Construction S pumps, range 58

Fig. 7 Explosion-proof motor with cooling jacket

TM04

230

9 23

08

17

Construction S pumps, range 58

18

Sectional drawings, pumps

Fig. 8 S1 pump

TM04

231

0 23

08

Construction S pumps, range 58

Fig. 9 SV pump

TM04

231

1 23

08

19

Construction S pumps, range 58

20

Fig. 10 S1 pump with DN 2 > DN 400

TM04

231

2 23

08

Construction S pumps, range 58

Fig. 11 Installation type S and C pump on auto coupling

TM04

231

5 23

08f

21

Construction S pumps, range 58

22

Fig. 12 Installation type D pump

TM04

231

6 23

08

731

Construction S pumps, range 58

Fig. 13 S1 pump, installation type H

Fig. 14 SV pump, installation type H

TM04

231

3 23

08TM

04 2

314

2308

23

Construction S pumps, range 58

24

Components and material specification

Motor

Pump

Accessories

* Ex versions have cast iron cable entry and two moisture switches.** Available of stainless steel (custom-built op ion).

Pos. Component Material (AISI/DIN W.-Nr.)7a Rivet Stainless steel (316/1.4436)

25a Screw Stainless steel (316/1.4436)

25 Pressure test plug Stainless steel (316/1.4436)

48 Stator lamination

**55 Stator housing Cast iron (EN-JL 1040/A48 30)

58 Seal housing Cast iron

60 Bearing bracket cover Cast iron

61c Upper bearing bracket Cast iron

72a O-ring NBR rubber

72 O-ring NBR rubber

76a Approval plate

100 O-ring NBR rubber

105b Mechanical seal SiC/SiC or SiC/carbon

105 Mechanical seal SiC/SiC or SiC/carbon

150c Cooling jacket Galvanised steel

153 Ball bearing Stainless steel

154 Ball bearing Stainless steel

**155 Lower bearing bracket Cast iron

157b O-ring NBR rubber

157 O-ring NBR rubber

**164a Motor top cover Cast iron

*168 Cable entry PA or cast iron

172 Shaft with rotor Stainless steel (329/1.4462)

173b Earth terminal

173c Washer Stainless steel (316/1.4436)

173e Screw Stainless steel (316/1.4436)

173f Spring washer Stainless steel (316/1.4436)

173g Earth connector

173 Screw Stainless steel (316/1.4436)

176a Terminal block

176b Screw Stainless steel (316/1.4436)

176c Terminal block

176d Terminal block

178 Screw Stainless steel (316/1.4436)

180 Cable clamp PA or cast iron

181a Screw Stainless steel (316/1.4436)

181 Cable ATON

182b Hexagon socket head cap screw Stainless steel (316/1.4436)

184b Screw Stainless steel (316/1.4436)

184 Screw Stainless steel (316/1.4436)

187a Washer Stainless steel (316/1.4436)

187 Circlip

188 Circlip

190 Lifting bracket Stainless steel (316/1.4408)

193 Plug Stainless steel (316/1.4408)

194 O-ring NBR rubber

197 Washer Stainless steel (316/1.4436)

198 Rubber seal

248 Screw Stainless steel (316/1.4436)

250a Cable entry PA or cast iron

250b Rubber seal

250 Cable clamp PA or cast iron

252 Cable ATON

520a Screw Stainless steel (316/1.4436)

520b Nut Stainless steel (316/1.4436)

*520 Moisture switch

522 Holder

Pos. Component Material (AISI/DIN W.-Nr.)7a Rivet

9a Key (for keyway) Stainless steel (316/1.4436)

12c Adjusting screw Stainless steel (316/1.4436)

26 Screw Stainless steel (316/1.4436)

37 O-ring NBR rubber

37b O-ring NBR rubber

**49 Impeller Cast iron EN-JL 1050

**50 Volute casing Cast iron EN-JS 1050

67 Impeller screw Stainless steel (316/1.4436)

76 Nameplate

301 Motor housing

494 Plug Stainless steel (316/1.4436)

495 O-ring NBR rubber

Pos. Component Material**701 Auto-coupling base unit Cast iron

**702 Guide rail bracket Cast iron

**703 Guide claw Cast iron

731 Base stand, vertical Galvanised steel

749 Bend Cast iron

751 Ring stand Galvanised steel

**761 Hose connector Cast iron or stainless steel

487 Base stand, horizontal Galvanised steel

799 Anchor bolt

Pos. Component Material (AISI/DIN W.-Nr.)

S pumps, range 58Product description

FeaturesSmartTrimOn conventional pumps, maintaining factory-set impeller clearance is a time-consuming and costly task. The pumps need to be disconnected from the pipework and to be totally dismantled, and new parts need to be mounted in order to maintain full pumping efficiency. Not so with Grundfos SmartTrim!

All Grundfos heavy-duty channel-impeller pumps, whether for submerged or dry installation, are equipped with the unique SmartTrim impeller clearance adjustment system. This enables you to easily restore factory-set impeller clearance and maintain peak pumping efficiency. All you need to do is to tighten the adjustment screws on the exterior of the impeller housing. This can be done on site, quickly and easily, without dismantling the pump and without using special tools.

A: With Grundfos SmartTrim impeller clearance adjustment system

B: Without impeller clearance adjustment system

SmartSealFor pumps with 10" discharge or larger, the Grundfos SmartSeal auto-coupling gasket mounted on the pump discharge flange provides a completely leak-proof connection between the pump and the base unit of the auto-coupling system. This optimises the efficiency of the entire pumping system and keeps operating costs at a minimum.

Ball bearingsThe bearings are greased for life.

Main bearings: Double-row angular contact ball bearing

Support bearings: Single-row deep-groove ball bearing.

Shaft sealThe pumps have a shaft seal consisting of a primary and a secondary shaft seal.

The material combination of the primary shaft seal of all pump types is silicon carbide/silicon carbide. For the secondary shaft seal, the mateial combination is silicon carbide/carbon.

The shaft seals are placed in the oil chamber of the pump. The oil chamber provides reliable sealing between the pumped liquid and the motor.

The shaft seals have no springs or other parts in direct contact with the pumped liquid. This prevents rags and fibres from getting caught. The shaft seals are bidirectional, meaning that they can operate in either direction thus allowing for opposite rotation caused by back-flow of liquid through the pump.

MotorThe motor is a watertight, totally encapsulated motor with:

• insulation class H (356 °F (180 °C))• temperature rise class F (221 °F (105 °C))• enclosure class IP68.For motor protection and sensors, see section Sensors below.

Power cables

Standard cable

EMC cable

Control cable

The cables are 40 ft (15 m) long as standard. Other cable lengths are available on request. See section List of variants on page 13.

The number and dimension of cables depend on the motor size.

TM04

239

1 25

08

Factory-set impeller clearance

Efficiency drop in %

Years

B

A

0

3

6

9

12

15

1 2 3 4 5 Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]4 x 6 0.62 (15.7) 0.68 (17.2) 4.3 (110)

4 x 10 0.82 (20.9) 0.92 (23.4) 5.5 (140)

Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]3 x 6 0.54 (13.6) 0.6 (15.2) 3 (76)

3 x 10 0.7 (17.8) 0.78 (19.8) 3.9 (99)

Cable type[mm2]

Outer cable diameter[inch (mm)]

Bending radius

min. max. [inch (mm)]

7 x 1.5 0.57 (14.4) 0.63 - 0.65(16.0 - 16.4) 4 (100)

25

Product description S pumps, range 58

26

Cable entryWatertight PA or cast iron cable entry with soft shape and sealing rings to prevent damage of the cable or leaks.

SensorsAs standard the pump is equipped with:

• Three thermal switches (Klixon), one in each phase.• One moisture switch in terminal block.

Customised sensor options1. WIO (water-in-oil) sensor

The WIO sensor measures the water content in the oil and converts the value into an analogue current signal. The two sensor conductors are for power supply as well as for carrying the signal to the mea-suring device or controller. The sensor measures the water content from 0 to 20 %. It also sends a signal if the water content is outside the normal range (warning), or if there is air in the oil chamber (alarm). The sensor is fitted in a stainless steel tube for mechanical protection.The WIO sensor is connected to the Grundfos IO 111 module.

2. Bearing temperature sensor.

TestingAll pumps are tested before leaving the factory. The factory test report is based on ANSI-HI centrifugal pump test 1.6-2000, Acceptance level B. Test reports can be ordered directly with the pump or can be ordered separately based on the pump serial number.

Other tests or third party inspection certificates are available on request including HI B & A standards. See section List of variants on page 13.

Operating conditionsPumps without cooling jacket in submerged installation:• Continuous operation when pump is fully sub-

merged to top of motor.• Intermittent operation with max. 20 starts per hour

when pump is submerged to middle of motor and with short periods of operation down to the top of the pump housingNote: Explosion proof pumps must always be fully submerged

Pumps with cooling jacket in submerged and dry installation:• Continuous and intermittent operation with max. 20

starts per hour with water level down to the top of the pump housing.

Pumped liquidspH value: 4-10

Liquid temperature: 32 °F - 104 °F (0 °C - +40 °C)

When pumping liquids with a density and/or a kinematic viscosity higher than that of water, use motors with correspondingly higher outputs.

Sound pressureThe sound pressure level of the pump is lower than the limiting values stated in the EC Council directive 2006/42/EC relating to machinery (the EC Machinery Directive).

Motor rangeShaft power [hp (kW)] No. of poles

34 (25) 442 (32) 4

Product description S pumps, range 58

Explosion-proof pumps

Approval standardsThese pumps are approved by FM according to FM3600, FM3615 and FM3615.80.

Explanation to FM approvalThe S pumps have the following explosion protection classification: Class I, Division 1, Groups C and D, T4, T3, IP68

Pump controllersS pumps, range 58, can be controlled by Grundfos Dedicated Controls (DC).

The Grundfos Dedicated Controls system can control from one to six pumps.

The Dedicated Controls system starts/stops the S pumps by means of:

• float switches,• pressure sensor or• ultrasonic sensor.Furthermore, it is possible to control the water level by both float switches and an analog pressure sensor or ultrasonic sensor.

Optionally, it can control a mixer and/or a flush valve. The Dedicated Controls system can be extended with an IO 111 module per pump (for S pumps with built-in analog sensor).

For further settings, see the installation and operating instructions for the pump controller selected.

Standards Code Description

FM3600FM3615FM3615.80

Class I Explosive atmosphere is caused by gas or vapours.

Division 1 Area classification

Groups C and D

Classification of gases

T4/T3 Maximum surface temperature is 275 °F (135 °C) and 392 °F (200 °C)

IP68 Enclosure class according to IEC 60529.

27

Product description S pumps, range 58

28

Wiring diagrams

Fig. 15 Wiring diagrams, Y-connected (460 V)

TM04

671

9 0

810

Sens

ors

Ther

mal

sw

itch

Moi

stur

e sw

itche

s

PT1

00 lo

wer

bea

ring

PT1

00 s

tato

r

Ther

mis

tor

Pow

er c

able M

otor

S pumps, range 58Curve charts/Technical data

The following many pages are divided into sections:

How to read the curve charts

Pages 29 and 30 A brief explanation of how to read the curve charts, the curve conditions, etc.

Performance curves and technical data:Page 34 Extra-low pressurePage 36 Low pressurePage 38 Medium pressurePage 40 High pressure

TM04

657

3 06

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 20 40 60 80 100 120 140 160 180 200 220Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]

NPSH

58L.S

60 Hz

ISO 9906 Annex A

S1.45.A80.420.4.

S1.45.A80.420.4.

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

15

20

25

30

35

40

45

[hp]

P2

15

20

25

30

[kW]

P2

S1.45.A80.420.4.

Pump type:

58: Range 58L: Pressure range (Low pressure)S: Installation type

Total pump head H = Htotal

The power curves indicate shaft power [P2] for the pumps shown

Max. efficiency mark

QH curve for the individual pump.

NPSH curve for all variants shown. When sizing the pumps, add a safety margin of at least 1.6 ft (0.5 m).

29

Curve charts/ Technical

S pumps, range 58

30

Curve conditionsThe guidelines below apply to the curves shown in the performance charts on page 32 to page 40.

• ANSI-HI centrifugal pump test 1.6-2000, Accep-tance level B.

• The curves show pump performance with different impeller diameters at rated speed.

• The bold part of the curves show the recom-mended operating range.

• The curves apply to the pumping of airless water at a temperature of 68 °F (+20 °C) and a kinematic vis-cosity of 1 cSt (1 mm2/s).

• NPSH: The curves show average values measured under the same conditions as the performance curves.When dimensioning the pump, add a safety margin of at least 1.6 ft (0.5 m).

• In case of other densities than 133.5 ounces/gallon (1000 kg/m3), the discharge pressure is proportional to the density.

• When pumping liquids with a density higher than 133.5 ounces/gallon (1000 kg/m3), motors with cor-respondingly higher outputs must be used.

Calculation of total headThe total pump head consists of the height difference between the measuring points + the differential head + the dynamic head.

Performance testsThe requested duty point for every pump is tested according to ISO 9906, Annex A, and without certifica-tion.

In case of pumps ordered on the basis of impeller diam-eter only (no requested duty point), the pump will be tested close to the best efficiency point (BEP) of the published performance curve which is related to the ordered impeller diameter (according to ISO 9906, Annex A).

If the customer requires either more points on the curve to be checked or certain minimum performances or cer-tificates, individual measurements must be made, and a certificate can be ordered.

CertificatesCertificates have to be confirmed for every order and are available on request as follows:

• Certificate of compliance with the order (EN 10204 - 2.1)

• Pump test sheet.

Witness testWhen the pumps are being tested or are tested with a certification it is possible for the customer to witness the testing procedure according to ISO 9906.

The witness test is not a certificate and will not result in a written statement from Grundfos. The witness itself is the only guarantee that everything is carried out as pre-scribed in the testing procedure.

If the customer wants to witness test the pump perfor-mance, place this request on the order.

Hgeo: Height difference between measuring points.

Hstat: Differential head between suction and the dis-charge side of the pump.

Hdyn: Calculated values based on the velocity of the pumped liquid on the suction and the discharge side of the pump.

Htotal Hgeo Hstat Hdyn+ +=

31

32

S pumps, range 58Performance curvesTechnical data

S 58 extra-low pressure, 6-pole

S2.40.A120.340

TM04

683

6 06

10

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

0

5

10

15

20

25

30

35

40

45

[ft]H

50 100 150 200 250 300 350Q [l/s]

0

2

4

6

8

10

12

14

[m]H

0

10

20

30

[ft]NPSH

58E.S

60 Hz

ISO 9906 Annex A

S2.40.A120.340.6.

S2.40.A120.340.6.

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]

10

15

20

25

30

35

[hp]

P2

10

15

20

25

[kW]

P2

S2.40.A120.340.6.

Performance curves Technical data

S pumps, range 58

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 m) cable

Pump type P1 [kW]

P2 [hp]

No. of poles RPM Starting

method

IN Istart ηmotor [%] Cos ϕ Moment of inertia

[lbft2 (kgm2]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S2.40.A120.340.6.58E 29 34 6 1160 Y/D 45 210 88 88 86 0.64 0.74 0.82 3. 56 (0.15 ) 227.9 (309)

Pump typeMax. solids size Max. installation depth Weight *

[inch (mm)] [feet (m)] [lbs (kg)]S2.40.A120.340.6.58E.S 4 (100) 66 (20) 1235 (560)S2.40.A120.340.6.58E.C 4 (100) 66 (20) 1367 (620)S2.40.A120.340.6.58E.D 4 (100) 66 (20) 1323 (600)S2.40.A120.340.6.58E.H 4 (100) 66 (20) 1455 (660)

33

Performance curves Technical data

S pumps, range 58

34

S 58 low pressure, 4-pole

S1.45.A80.420

TM04

657

3 06

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 20 40 60 80 100 120 140 160 180 200 220Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]

NPSH

58L.S

60 Hz

ISO 9906 Annex A

S1.45.A80.420.4.

S1.45.A80.420.4.

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

15

20

25

30

35

40

45

[hp]

P2

15

20

25

30

[kW]

P2

S1.45.A80.420.4.

TM04

657

4 06

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 20 40 60 80 100 120 140 160 180 200 220Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]

NPSH

58L.C/D/H

60 Hz

ISO 9906 Annex A

S1.45.A80.420.4.

S1.45.A80.420.4.

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Q [US GPM]

15

20

25

30

35

40

45

[hp]

P2

15

20

25

30

[kW]

P2

S1.45.A80.420.4.

Performance curves Technical data

S pumps, range 58

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 m) cable

Pump type P1 [kW]

P2 [hp]

No. of poles RPM Starting

method

IN Istart ηmotor [%] Cos ϕ Moment of inertia

[lbft2 (kgm2]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.45.A80.420.4.58L 35 42 4 1749 Y/D 52 284 89 90 88 0.75 0.82 0.85 3. 56 (0.15 ) 286.9 (389)

Pump typeMax. solids size Max. installation depth Weight *

[inch (mm)] [feet (m)] [lbs (kg)]S1.45.A80.420.4.58L.S 4.5 (115) 66 (20) 1080 (490)S1.45.A80.420.4.58L.C 4.5 (115) 66 (20) 1190 (540)S1.45.A80.420.4.58L.D 4.5 (115) 66 (20) 1301 (590)S1.45.A80.420.4.58L.H 4.5 (115) 66 (20) 1301 (590)

35

Performance curves Technical data

S pumps, range 58

36

S 58 low pressure, 4-pole

S2.40.A80.420

TM04

657

5 06

10

400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]

0

10

20

30

40

50

60

70

80

[ft]H

40 80 120 160 200 240 280Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

40

[ft]NPSH

58L.S

60 Hz

ISO 9906 Annex A

S2.40.A80.420.4.

S2.40.A80.420.4.

400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]

15

20

25

30

35

40

[hp]

P2

15

20

25

30

[kW]

P2

S2.40.A80.420.4.

TM04

657

6 60

10

0 400 800 1200 1600 2000 2400 2800 3200 3600 4000Q [US GPM]

0

10

20

30

40

50

60

70

80

90

[ft]H

0 40 80 120 160 200 240 Q [l/s]

0

5

10

15

20

25

[m]H

0

10

20

30

[ft]NPSH

58L.C/D/H

60 Hz

ISO 9906 Annex A

S2.40.A80.420.4.

S2.40.A80.420.4.

0 400 800 1200 1600 2000 2400 2800 3200 3600 4000Q [US GPM]

25

30

35

40

45

50

[hp]

P2

20

25

30

35

[kW]

P2

S2.40.A80.420.4.

Performance curves Technical data

S pumps, range 58

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 m) cable

Pump type P1 [kW]

P2 [hp]

No. of poles RPM Starting

method

IN Istart ηmotor [%] Cos ϕ Moment of inertia

[lbft2 (kgm2]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S2.40.A80.420.4.58L 35 42 4 1749 Y/D 52 284 89 90 88 0.75 0.82 0.85 3. 56 (0.15 ) 286.9 (389)

Pump typeMax. solids size Max. installation depth Weight *

[inch (mm)] [feet (m)] [lbs (kg)]S2.40.A80.420.4.58L.S 4 (100) 66 (20) 1080 (490)S2.40.A80.420.4.58L.C 4 (100) 66 (20) 1190 (540)S2.40.A80.420.4.58L.D 4 (100) 66 (20) 1301 (590)S2.40.A80.420.4.58L.H 4 (100) 66 (20) 1301 (590)

37

Performance curves Technical data

S pumps, range 58

38

S 58 medium pressure, 4-pole

S1.40.A50.420

TM04

657

7 06

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0

20

40

60

80

100

120

140

[ft]H

0 20 40 60 80 100 120 140 160 Q [l/s]

0

10

20

30

40

[m]H

0

10

20

30

40

50

[ft]

NPSH

58M.S

60 Hz

ISO 9906 Annex A

S1.40.A50.420.4.

S1.40.A50.420.4.

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

15

20

25

30

35

40

[hp]

P2

15

20

25

30

[kW]

P2

S1.40.A50.420.4.

TM04

657

8 06

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0

20

40

60

80

100

120

140

[ft]H

0 20 40 60 80 100 120 140 160 Q [l/s]

0

10

20

30

40

[m]H

0

10

20

30

40

50

[ft]

NPSH

58M.C/D/H

60 Hz

ISO 9906 Annex A

S1.40.A50.420.4.

S1.40.A50.420.4.

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

20

25

30

35

40

45

[hp]

P2

15

20

25

30

[kW]

P2

S1.40.A50.420.4.

Performance curves Technical data

S pumps, range 58

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 m) cable

Pump type P1 [kW]

P2 [hp]

No. of poles RPM Starting

method

IN Istart ηmotor [%] Cos ϕ Moment of inertia

[lbft2 (kgm2]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.40.A50.420.4.58M 35 42 4 1749 Y/D 52 284 89 90 88 0.75 0.82 0.85 3. 56 (0.15 ) 286.9 (389)

Pump typeMax. solids size Max. installation depth Weight *

[inch (mm)] [feet (m)] [lbs (kg)]S1.40.A50.420.4.58M.S 4 (100) 66 (20) 992 (450)S1.40.A50.420.4.58M.C 4 (100) 66 (20) 1102 (500)S1.40.A50.420.4.58M.D 4 (100) 66 (20) 1190 (540)S1.40.A50.420.4.58M.H 4 (100) 66 (20) 1190 (540)

39

Performance curves Technical data

S pumps, range 58

40

S 58 high pressure, 4-pole

S1.30.A50.340

TM04

657

1 06

10

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

0

20

40

60

80

100

120

140

160

180

[ft]H

0 10 20 30 40 50 60 70 80 Q [l/s]

0

10

20

30

40

50

[m]H

0

10

20

30

40

[ft]

NPSH

58H.S

60 Hz

ISO 9906 Annex A

S1.30.A50.340.4.

S1.30.A50.420.4.

S1.30.A50.340.4.

S1.30.A50.420.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Q [US GPM]

10

15

20

25

30

35

40

[hp]

P2

10

15

20

25

[kW]

P2

S1.30.A50.340.4.

S1.30.A50.420.4.

TM04

657

2 06

10

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

0

20

40

60

80

100

120

140

160

180

[ft]H

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

10

20

30

40

50

[m]H

0

10

20

30

40

[ft]

NPSH

58H.C/D/H

60 Hz

ISO 9906 Annex A

S1.30.A50.340.4.

S1.30.A50.420.4.

S1.30.A50.340.4.

S1.30.A50.420.4.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [US GPM]

15

20

25

30

35

40

45

[hp]

P2

15

20

25

30

[kW]

P2

S1.30.A50.340.4.

S1.30.A50.420.4.

Performance curves Technical data

S pumps, range 58

Electrical data

Note: Enclosure class: IP68

Pump data

* Wi h 50 ft (15 m) cable

Pump type P1 [kW]

P2 [hp]

No. of poles RPM Starting

method

IN Istart ηmotor [%] Cos ϕ Moment of inertia

[lbft2 (kgm2]

Breakdown torque Mmax [lbf*ft (Nm)][A] [A] 1/2 3/4 1/1 1/2 3/4 1/1

S1.30.A50.340.4.58H 31 34 4 1752 Y/D 47 284 88 90 89 0.73 0.80 0.84 3. 56 (0.15 ) 286.9 (389)S1.30.A50.420.4.58H 36 42 4 1746 Y/D 54 284 89 90 88 0.75 0.82 0.85 3. 56 (0.15 ) 286.9 (389)

Pump typeMax. solids size Max. installation depth Weight *

[inch (mm)] [feet (m)] [lbs (kg)]S1.30.A50.340.4.58H.S 3 (80) 66 (20) 970 (440)S1.30.A50.340.4.58H.C 3 (80) 66 (20) 1058 (480)S1.30.A50.340.4.58H.D 3 (80) 66 (20) 1146 (520)S1.30.A50.340.4.58H.H 3 (80) 66 (20) 1146 (520)S1.30.A50.420.4.58H.S 3 (80) 66 (20) 970 (440)S1.30.A50.420.4.58H.C 3 (80) 66 (20) 1058 (480)S1.30.A50.420.4.58H.D 3 (80) 66 (20) 1146 (520)S1.30.A50.420.4.58H.H 3 (80) 66 (20) 1146 (520)

41

42

S pumps, range 58Accessories

Accessories (for installation)

* Installation type S and C pumps with discharge flange size NPS 10" (DN 250) and higher are supplied with guide claw mounted on the flange.

Pump type Installation accessoriesS 50-70 S and C NPS 3-8 (DN 80-200) without guide claw (guide claw included in auto-coupling kit)S 50-70 S and C NPS 10-24 (DN 250-600) with guide claw mounted on the pumpS 50-70 D Pump without installation accessories (accessories as separate kit)S 50-70 H Base stand for horizontal, dry installation supplied together with the pump

Pictures Description Size Weight[lb (kg)] PN Product

number

GR

8126

Cast-iron, epoxy-coated auto-coupling system complete with:• guide claw *• base unit• upper guide rail bracket• gaskets and bolts.

Dis

char

ge fl

ange NPS 8" (DN 200) 617.3

(280) 10 97506541

NPS 5"/NPS 6"(DN 125/150)

229 28(104) 10 97626242

NPS 12"(DN 300)

738.5 (335) 10 97510049

Intermediate guide rail bracket For guide rails longer than 19.5 feet (6 m)

NPS 5"/NPS 6"(DN 125/DN150) 6.6 (3) 96829331

NPS 8" / NPS 24"(DN 200/DN 600) 17.6 (8) 96255842

Guide rails Standard pipes. Not supplied by Grundfos

Stand/pump discharge - hose

TM02

885

6 09

04 -

TM02

885

7 09

04

Cast iron, epoxy-coated ring stand.Supplied with bolts, nuts, gaskets and anchor bolts.

NPS 4" / NPS3"(DN 100 / DN 80) 10 96856259

NPS 5" (DN 130) 10 96856262

NPS 8" (DN 200) 10 96790704

TM04

403

5 05

09

Vertical base stand (without bend).

Suc

tion

flang

e

NPS 6" (DN150) 96308238

NPS 8" (DN 200) 96094523

NPS 10" (DN250) 96856263

TM04

415

6 09

09

Galvanised steel base stand for horizontal, dry installa-tion.Supplied with bolts, gaskets and anchor bolts.

NPS 6" (DN150) 96782930

NPS 8" (DN 200) 96784437

NPS 10" (DN250) 96856265

Accessories S pumps, range 58

Other accessories

Pictures Description Dimensions Product number

TM02

612

6 51

02

13 ft (4 m) galvanised lifting chain with lifting link and safety hook.With certificates.

Max. 1763 lbs (800 kg) S 34-58

96735550

20 ft (6 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735553

26 ft (8 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735554

33 ft (10 m) galvanised lifting chain with lifting link and safety hook. With certificates. 96735556

40 ft (12 m) galvanised lifting chain with lifting link and safety hook.With certificates. 96735557

13 ft (4 m) stainless steel lifting chain with lifting link and safety hook.With certificates.

Max. 1763 lbs(800 kg) S 34-58

96735559

20 ft (6 m) stainless steel lifting chain with lifting link and safety hook. With certificates. 96735564

26 ft (8 m) stainless steel lifting chain with lifting link and safety hook. With certificates. 96735566

33 ft (10 m) stainless steel lifting chain with lifting link and safety hook.With certificates. 96735567

40 ft (12 m) stainless steel lifting chain with lifting link and safety hook. With certificates. 96735569

TM01

698

2 39

99

Float switch with 33 ft (10 m) cable 96003332

Float switch with 66 ft (20 m) cable 96003695

TM02

886

2 09

04

Bracket for two float switches 96003338

TM02

067

0 50

00

Float switches with bracket, 33 ft (10 m) cable

2 switches, 1 pump without alarm 62500013

3 switches, 1 pump with alarm 62500014

3 switches, 2 pumps with alarm 62500014

4 switches, 2 pumps with alarm 62500015

43

44

S pumps, range 58Dimensions

Installation on auto coupling

Fig.

16

Dim

ensi

onal

ske

tche

s, in

stal

latio

n on

aut

o-co

uplin

g sy

stem

Z12a

is m

inim

um re

com

men

ded

dist

ance

from

pit

botto

m to

bot

tom

of p

ump

suct

ion

side

.

Z11

is to

tal h

eigh

t of p

ump

inst

alle

d on

Gru

ndfo

s in

stal

latio

n ac

cess

ory

in th

e pi

t. N

OTE

: Thi

s fig

ure

mig

ht n

ot e

qual

Z12

a +

Z1.

Not

e:

TM04 2417 2508

Z14

Z17

G/S

Min

. lev

el,

nsta

llatio

n S

Min

. lev

el, i

nsta

l-at

ion

C

Dimensions S pumps, range 58

S pu

mps

, ran

ge 5

8 [in

ch]

ZM

4XM

164X

M16

4XM

16

ZL2

5.8

5.8

5.8

ZL1

22.5

22.5

22.5

ZDt1

1.0

1.0

1.0

ZDN

1

6"

6"

6"

ZDc1

9.4

9.4

9.4

Z17 S 0.

10.

10.

1

G 0.1

0.1

0.1

Z16

22.6

22.6

22.6

Z15

11.0

11.0

11.0

Z14 - - -

Z13 - - -

Z12b

15.7

15.7

15.7

Z12a

3.1

3.1

3.9

Z11

55.2

55.2

55.6

Z10

3.5

3.5

3.5

Z9 4.3

4.3

4.3

Z8 26.7

26.7

25.9

Z7 35.5

35.5

34.7

Z6 47.9

47.9

47.1

Z4 11.0

11.0

11.0

Z3 4.8

4.8

4.8

Z2 11.8

11.8

11.8

Z1 47.3

47.3

48.7

ZØ1

8X23

8X23

8X23

F

17.7

17.7

18.2

C 25.4

25.4

24.6

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

40.A

50.4

20.4

.58M

S pu

mps

, ran

ge 5

8 [m

m]

ZM

4XM

164X

M16

4XM

16

ZL2

147

147

147

ZL1

571

571

571

ZDt1

25 25 25

ZDN

1

6"

6"

6"

ZDc1

240

240

240

Z17 S 3.

03.

03.

0

G 3.0

3.0

3.0

Z16

575

575

575

Z15

280

280

280

Z14 - - -

Z13 - - -

Z12b

400

400

400

Z12a 80 80 100

Z11

1402

1402

1411

Z10

88.0

88.0

88.0

Z9 110

110

110

Z8 678

678

657

Z7 902

902

882

Z6 1216

1216

1196

Z4 280

280

280

Z3 123

123

123

Z2 300

300

300

Z1 1202

1202

1236

ZØ1

8X23

8X23

8X23

F 450

450

462

C 645

645

625

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

40.A

50.4

20.4

.58M

45

Dimensions S pumps, range 58

46

Fig.

17

Dim

ensi

onal

ske

tche

s, in

stal

latio

n on

aut

o-co

uplin

g sy

stem

Z12a

is m

inim

um re

com

men

ded

dist

ance

from

pit

botto

m to

bot

tom

of p

ump

suct

ion

side

.

Z11

is to

tal h

eigh

t of p

ump

inst

alle

d on

Gru

ndfo

s in

stal

latio

n ac

cess

ory

in th

e pi

t. N

OTE

: Thi

s fig

ure

mig

ht n

ot e

qual

Z12

a +

Z1.

Not

e:

TM04 2416 2508

Z17

G/S

Min

, lev

el,

nsta

llatio

n S

Min

. lev

el,

nsta

llatio

n C

Dimensions S pumps, range 58

S pu

mps

, ran

ge 5

8 [in

ch]

ZM

4XM

244X

M24

4XM

24

ZL2

8.7

8.7

8.7

ZL1

30.0

30.0

35.5

ZDt1

1.2

1.2

1.3

ZDN

1

8"

8"

12"

ZDc1

11.6

11.6

15.7

Z17 S 0.

10.

10.

1

G 0.1

0.1

0.1

Z16

19.1

19.1

25.6

Z15

14.4

14.4

17.7

Z14

3.4

3.4

3.7

Z13

5.9

5.9

5.9

Z12b

7.7

7.7

10.1

Z12a

5.2

5.2

6.1

Z11

54.4

54.4

55.8

Z10

3.5

3.5

3.5

Z9 6.7

6.7

6.7

Z8 37.1

37.1

41.0

Z7 48.3

48.3

57.1

Z6 62.8

62.8

77.1

Z4 21.1

21.1

26.4

Z3 7.9

7.9

7.9

Z2 16.9

16.9

21.7

Z1 49.2

49.2

49.7

ZØ1

8X23

8X23

12X

23

F

26.8

26.8

32.6

C 32.9

32.9

41.7

Pum

p ty

pe

S1.

45.A

80.4

20.4

.58L

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

S pu

mps

, ran

ge 5

8 [m

m]

ZM

4XM

244X

M24

4XM

24

ZL2

222

222

222

ZL1

761

761

901

ZDt1

31 31 32

ZDN

1

8"

8"

12"

ZDc1

295

295

400

Z17 S 3.

03.

03.

0

G 3.0

3.0

3.0

Z16

485

485

650

Z15

365

365

450

Z14

86 86 95

Z13

150

150

150

Z12b

196

196

256

Z12a

131

131

156

Z11

1381

1381

1418

Z10

88.0

88.0

88.0

Z9 170

170

170

Z8 942

942

1042

Z7 1227

1227

1450

Z6 1596

1596

1959

Z4 535

535

670

Z3 200

200

200

Z2 430

430

551

Z1 1250

1250

1262

ZØ1

8X23

8X23

12X

23

F 680

680

828

C 835

835

1058

Pum

p ty

pe

S1.

45.A

80.4

20.4

.58L

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

47

Dimensions S pumps, range 58

48

Installation on ring stand

Fig.

18

Dim

ensi

onal

ske

tch,

inst

alla

tion

on ri

ng s

tand

TM04 2420 2508

HC

L

Dimensions S pumps, range 58

S pu

mps

, ran

ge 5

0 [in

ch]

F

17.7

17.7

26.8

18.2

26.8

32.6

D 9.3

9.3

15.0

9.3

15.0

18.4

DST

H

8.3

8.3

8.3

8.3

8.3

8.9

HC

L

11.4

11.4

16.5

11.4

16.5

24.5

HC

H

11.0

11.0

17.1

11.0

17.1

23.6

Y5 21.7

21.7

21.7

21.7

21.7

27.6

Y4 38.8

38.8

48.9

38.0

48.9

63.9

Y3 27.2

27.2

33.9

28.1

33.9

42.4

Y2

16.1

16.1

16.7

17.1

16.7

18.7

Y1 55.6

55.6

57.5

56.9

57.5

58.6

Y Ø

2

0.2

0.2

8.1

0.2

8.1

0.5

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

S pu

mps

, ran

ge 5

0 [m

m]

F 450

450

680

462

680

828

D 237

237

380

237

380

468

DST

H

210

210

210

210

210

226

HC

L

289

289

418

289

418

622

HC

H

280

280

435

280

435

600

Y5 550

550

550

550

550

700

Y4 985

985

1243

964

1243

1622

Y3

690

690

860

715

860

1.07

6

Y2 410

410

425

435

425

476

Y1 1412

1412

1460

1446

1460

1488

Y Ø

2

6 6 205 6 205

12

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

49

Dimensions S pumps, range 58

50

Dry pit, vertical installation

Fig.

19

Dim

ensi

onal

ske

tch,

dry

, ver

tical

inst

alla

tion

TM04 2422 2508

X13

X13

1

Dimensions S pumps, range 58

S pu

mps

, ran

ge 5

8 [in

ch]

XM1

M20

X6

M20

X6

M24

X6

M20

X6

M24

X6

M24

X6

Dt2 0.9

0.9

1.0

0.9

1.0

1.3

XDt1

0.9

0.9

1.1

1.0

1.1

1.1

XDc3

9.4

9.4

14.3

11.6

14.3

14.3

X17

33.6

33.6

43.5

38.6

43.5

44.8

X16

73.0

73.0

84.3

78.4

84.3

84.6

X132

4.7

4.7

5.9

4.7

5.9

5.9

X131

5.9

5.9

7.9

6.9

7.9

7.9

X13

17.7

17.7

23.6

20.7

23.6

23.6

X10

6" 6" 10"

8" 10"

10"

X6 24.4

24.4

33.7

28.3

33.7

33.7

X5 11.7

11.7

16.7

13.5

16.7

16.7

X4 11.8

11.8

15.7

13.8

15.7

15.7

XØ5

0.9

0.9

1.1

0.9

1.1

1.1

XØ3

0.9

0.9

0.9

0.9

0.9

0.9

F

17.7

17.7

26.8

18.2

26.8

32.6

C 25.4

25.4

32.9

24.6

32.9

41.7

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

S pu

mps

, ran

ge 5

8 [m

m]

XM1

M20

X6

M20

X6

M24

X6

M20

X6

M24

X6

M24

X6

Dt2 22 22 26 22 26 33

XDt1

24 24 28 26 28 28

XDc3

240

240

362

295

362

362

X17

853

853

1106

981

1106

1139

X16

1855

1855

2141

1992

2141

2150

X132

120

120

150

120

150

150

X131

150

150

200

175

200

200

X13

450

450

600

525

600

600

X10

6" 6" 10"

8" 10"

10"

X6 621

621

857

719

857

857

X5 296

296

425

344

425

425

X4 300

300

400

350

400

400

XØ5

24 24 28 24 28 28

XØ3

24 24 24 24 24 24

F 450

450

680

462

680

828

C 645

645

835

625

835

1058

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

51

Dimensions S pumps, range 58

52

Dry pit, horisontal installation

Fig.

20

Dim

ensi

onal

ske

tch,

dry

, hor

ison

tal i

nsta

llatio

n

TM04 2414 2508

QZ1

Dimensions S pumps, range 58

S pu

mps

, ran

ge 5

8 [in

ch]

Dt2 0.9

0.9

1.0

0.9

1.0

1.3

Dc2 8.5

8.5

11.7

8.5

11.7

17.0

2

0.9

0.9

0.9

0.9

0.9

0.9

D2N 5" 5" 8" 5" 8" 12

"

D2N 8 8 8 8 8 12

QZ1 0.7

0.7

0.7

0.7

0.7

0.7

1

M20

M20

M20

M20

M20

M20

D1N 8 8 12 8 12 12

DN

1

6" 6" 10"

8" 10"

10"

QD

c1

9.4

9.4

14.3

11.7

14.3

14.3

Q10

32.1

32.1

32.1

32.1

32.1

32.1

Q8

15.4

15.4

15.4

15.4

15.4

15.4

Q6

19.7

19.7

19.7

19.7

19.7

19.7

Q5

4.5

4.5

4.5

4.5

4.5

4.5

Q4

14.8

14.8

21.7

14.8

21.7

21.7

Q3

31.3

31.3

43.3

30.5

43.3

47.2

Q2

9.8

9.8

10.5

11.0

10.5

11.8

Q1

49.3

49.3

51.3

50.8

51.3

51.6

3

0.7

0.7

0.7

0.7

0.7

0.7

F

17.7

17.7

26.8

18.2

26.8

32.6

D 9.3

9.3

15.0

9.3

15.0

18.4

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

S pu

mps

, ran

ge 5

8 [m

m]

Dt2 22 22 26 22 26 33

Dc2 216

216

298

216

298

432

2

22 22 24 22 24 24

D2N 5" 5" 8" 5" 8" 12

"

D2N 8 8 8 8 8 12

QZ1 18 18 18 18 18 18

1

M20

M20

M20

M20

M20

M20

D1N 8 8 12 8 12 12

DN

1

6" 6" 10"

8" 10"

10"

QD

c1

240

240

362

298

362

362

Q10

815

815

815

815

815

815

Q8

390

390

390

390

390

390

Q6

500

500

500

500

500

500

Q5

115

115

115

115

115

115

Q4

375

375

550

375

550

550

Q3

796

796

1100

775

1100

1200

Q2

250

250

267

280

267

300

Q1

1252

1252

1302

1291

1302

1311

3

18 18 18 18 18 18

F 450

450

680

462

680

828

D 237

237

380

237

380

468

Pum

p ty

pe

S1.

30.A

50.3

40.4

.58H

S1.

30.A

50.4

20.4

.58H

S1.

45.A

80.4

20.4

.58L

S1.

40.A

50.4

20.4

.58M

S2.

40.A

80.4

20.4

.58L

S2.

40.A

120.

340.

6.58

E

53

54

S pumps, range 58Further product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages.

In WebCAPS, all information is divided into 6 sections:

• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.

Catalogue

This section is based on fields of application and pump types, and contains • technical data• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-

sity and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures, etc.

Service

This section contains an easy-to-use interactive service cata-logue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps.Furthermore, this section contains service videos showing you how to replace service parts.

Further product documentation

S pumps, range 58

WinCAPS

Fig. 21 WinCAPS CD-ROM

WinCAPS is a Windows-based Computer Aided Prod-uct Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages.

The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet con-nection is available.

WinCAPS is available on CD-ROM and updated once a year.

Sizing

This section is based on different fields of application and installa-tion examples, and gives easy step-by-step instructions in how to• select the most suitable and efficient pump for your installation• carry out advanced calculations based on energy consumption,

payback periods, load profiles, life cycle costs, etc.• analyse your selected pump via the built-in life cycle cost tool• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing re-placement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grund-fos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

Subject to alterations.

55