s-850 utility summary · 2019. 8. 28. · 7/19/2013 s-850 spiral system new logic research...
TRANSCRIPT
![Page 1: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/1.jpg)
![Page 2: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/2.jpg)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 1 OF 4
DRAWN
CHECKED
QA
MFG
APPROVED
DWG NO
850-00
TITLE
SIZE
CSCALE
REVG. Johnson
F. Rubin NEW LOGIC RESEARCH
SPIRAL 850 SERIES SYSTEM
NOTES:1.New Logic Research confidential material.2.All dimensions are in inches.3.Preliminary, for references only.
10.26.09
ISO VIEW
Frame 850-01
Feed plumbing 850-02-03 Stage 2
Frame support 850-01-10 (2x)
Permeate plumbing 850-02-01
Concentrate plumbing 850-02-02
Bottom plumbing 850-02-04
600 Psi Code Line Spiral (10x) 850-04
Pump CRN 5-16
Pump CRN 5-24SF
Electrical enclosure 850-05
Feed plumbing 850-02-03 Stage 1
![Page 3: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/3.jpg)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 2 OF 4
DRAWN
CHECKED
QA
MFG
APPROVED
DWG NO
850-00
TITLE
SIZE
CSCALE
REVG. Johnson
F. Rubin NEW LOGIC RESEARCH
SPIRAL 850 SERIES SYSTEM
NOTES:1.New Logic Research confidential material.2.All dimensions are in inches.3.Preliminary, for references only.
10.26.09
FRONT VIEW
64.30
62.00
43.5
55.1252.00
![Page 4: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/4.jpg)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 3 OF 4
DRAWN
CHECKED
QA
MFG
APPROVED
DWG NO
850-00
TITLE
SIZE
CSCALE
REVG. Johnson
F. Rubin NEW LOGIC RESEARCH
SPIRAL 850 SERIES SYSTEM
NOTES:1.New Logic Research confidential material.2.All dimensions are in inches.3.Preliminary, for references only.
10.26.09
SIDE VIEWS
53.16
0.0
5.6
27.6
32.8
37.4
42.6
0.03.619.826.0
0.0
12.0
16.0
19.3
23.6
31.2
39.2
46.4
7.65
38.9
![Page 5: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/5.jpg)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 4 OF 4
DRAWN
CHECKED
QA
MFG
APPROVED
DWG NO
850-00
TITLE
SIZE
CSCALE
REVG. Johnson
F. Rubin NEW LOGIC RESEARCH
SPIRAL 850 SERIES SYSTEM
NOTES:1.New Logic Research confidential material.2.All dimensions are in inches.3.Preliminary, for references only.
10.26.09
TOP VIEW
47.507.25
33.00
41.15
42.00
0.89.00
0.0 4.8 16.6 23.3 32.0 44.1 55.7
![Page 6: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/6.jpg)
7/19/2013 S-850 Spiral System
New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax: (510) 655-7307
SPIRAL SYSTEM COMPONENT SPECIFICATIONS
S-850 Spiral System 1] Filter Pack Membrane: ESPA 4040, SWC 4040
Membrane Surface Area: 850sf (197.7 m2) (10ea 4”Dia x 40”L) Estimated Production: 16.6 gpm (at 5-10GFD)
Maximum Operating Temperature: 120 oF (49ºC) (Options for up to 80ºC) Allowable Feed Slurry pH Range: 2-11 (Options for 1-14) O-ring Material: Ethylene Propylene Filter Pack Housing: Polyurethane Coated, Filament Wound, Epoxy FRP Wetted Ports: 316L Stainless Steel Wetted Plastic End Plates: PVC Thermoplastic 2] Piping Maximum Pressure: 550 psi (Options for up to 1200 psi) Pressure Piping: 316L Stainless Steel Tubing
Atmospheric Piping: CPVC Schedule 80 Pipe Clamps: None On/Off Valves: CPVC 3-piece ball valve Flow Control Valves: 316 SS Globe Check Valves: CPVC ball check valve Pneumatic Actuators: None
Positioners: None Skid Pipe Terminations: 150 lb 316 SS Raised Face Flange Flange Gaskets: 150 lb Garlock Blue Guard Clean in Place Tank: 15 gallon PolyPro 15” Dia x 19” Height
3] Pump Specifications:
Feed Pump Type: Grundfos 316SS Vertical Multi-stage Centrifugal Feed Pump Motor: Grundfos ML 3500 rpm TEFC 460VAC, 3phase Motor Speed Controller: AC Tech 380-480VAC, NEMA 4 (or Equal)
5] Operating Site Conditions: Equipment Rating: NEMA 4, Indoor/Outdoor protect from sunlight & rain. Ambient Temperature: 5 - 37°C Storage Temperature: 2 - 70°C (Protect Filter Pack from Freezing) Max Relative Humidity: <95%, non-condensing Elevation: 3300 ft maximum without derating
![Page 7: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/7.jpg)
7/19/2013 S-850 Spiral System
New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax: (510) 655-7307
SPIRAL SYSTEM COMPONENT SPECIFICATIONS (continued) 6] Electrical Specifications:
Controls Voltage: None Programmable Controller Type: None Touch Screen Display Type: None
Enclosures: Hoffman NEMA 4 Powdercoat Finish 10x12x6 Switches, Relays, & Contactors: Allen Bradley 120/220 Volt Pressure Sensors: Wika Gauges
Mag Flow Tube and Transmitter: IFM Efector SM6001, SM0504 Bag Filter DP Sensors: None Temperature Sensor: None
Conductivity Meter: None pH Meter: None Level Sensors: None Solenoid Valves None
VFD Communication: None
![Page 8: S-850 Utility Summary · 2019. 8. 28. · 7/19/2013 S-850 Spiral System New Logic Research Confidential Material 1295 67th Street, Emeryville, CA 94608 Phone: (510) 655-7305 Fax:](https://reader036.vdocuments.site/reader036/viewer/2022071502/6121c10ebbb97a23c46d1485/html5/thumbnails/8.jpg)
Utility Summary New Logic ResearchSpiral RO System
AIR CONSUMPTION
M3/hrSpiral RO No Pneumatic ActuatorsSystem Air Totals 0Supply air to Spiral Enclosure at 80-90 psi (560-630kPa)
Supply air to Regulator/Filter 3/8" NPT Connection (Spiral Enclosure)
CLEANING WATER CONSUMPTION (Use Hot Water for cleaning water >300 uS/cm)
M3/hr
Spiral RO Cleanings 0.0221Rinse filter pack at 20gpm for 5mins 0.0022
0.0005
System Water Totals 0.0248Supply Water at 50-60degC and 20gpm (4.5 m3/hr)Supply water at 20 psi to 1" Hot Water flange connection on Spiral Skid
ELECTRICAL CONSUMPTIONBased on 380-480 VAC, 3 phase, 50/60hz InputFLA = Full Load Amps = Full Load Drive Output x 1.15xRLA = Running Load Amps = FLA x .65x
Spiral RO 380-480 VAC Motors
# MotorsHP /ea kW /ea
Amps /ea FLA /ea
RLA /ea
Total kW
Total FLA
Total RLA
Spiral RO Feed Pump 1 5 3.8 10.6 12.2 7.9 3.8 12.2 7.9Spiral RO Feed Pump Booster 1 10 7.6 18.1 20.8 13.5 7.6 20.8 13.5
Totals 2 11.4 33.0 21.5
Spiral RO 120-240 VAC, 1 phase 50/60 HzNo Main Control Enclosures 0 0.0 0.0
Totals 0 0.0 0.0 0.0Supply power to circuit breakers in Spiral Enclosure
0.10
0.033
50-60
Temp degC Gallons/Day
System Totals
0.0050-60
0.140.14
14050-60
CFMStrokes/dayIn^3 Air/stroke# of Valves
Note: These are estimates only based on very preliminary data. These calculations are subject to change and do not
include equipment offskid of Spiral RO system
Supply power to from customer supplied Load Pannel to the VFDs mounted on the skid, NLR supplies from VFDs to Motors
Intermittent need of additional cleaning or flush of filter pack
System Totals 0.00
# /Day GPM
0.11
143.3
0.01
Confidential 5/16/2013 S-850 System