FORM NO. P22-743 REV. 3 Supersedes Form No. P22-743 Rev. 2

HEAT PUMPS

*“CERTIFIED UNDER THEA.R.I. CERTIFICATION

PROGRAM—A.R.I. STANDARD 240-81”

THIS MODEL

ENER UIDE

17.010.0

12.00

USES LESS ENERGY

Seasonal Energy Efficiency Ratio - SEER

UPMC- SERIESSeven ModelsNominal Sizes 11/2 to 5 Tons[5.28 kW] to [17.6 kW]

ACHIEVER 12® HIGHEFFICIENCY HEAT PUMPOUTDOOR UNITSThe Ruud® UPMC- Achiever 12 Heat Pump Outdoor unitscan provide year-round heating and cooling comfort forresidential, multi-family and light commercial applications.They are designed to operate with Ruud indoor units withcooling and heating capacities certified under the ARICertification program.The Ruud UBHC- and UBHK- Air Handlers equipped withauxiliary heating elements for supplementary heat wasdesigned especially for use with the UPMC- Heat Pump.Together they provide systems capable of delivering amaximum HSPF (Heating Seasonal Performance Factor)of 8.65 in the heating mode or a maximum standardS.E.E.R. (Seasonal Energy Efficiency Ratio) of 13.85 in thecooling mode.The following additional features, plus its energy-savingcharacteristics, make the UPMC- Heat Pump outdoor unitan excellent choice for new construction or upgrading yourpresent system.� Attractive, louvered wrap around jacket protects coil from

weather extremes and yard hazards. Top grille is steelreinforced for extra strength. Cabinet is powder paintedfor all weather protection.

� Four sided outdoor coil design allows compressor opera-tion with access panel removed.

� Air is discharged upward away from bushes and shrubs.The discharge pattern of the top grille provides minimumair restriction, resulting in quiet fan operation.

� Exclusive Combination Grille/Motor Mount* secures thefan motor to the underside of the discharge grille. Thegrille protects the motor windings and bearings from rainand snow.

� All controls are accessible by removing one servicepanel. Removable top grille provides access to the out-door fan motor and outdoor coil.

� Compressor compartment offers additional protectionfrom the elements and reduces operating noise.

� Single speed, 6-pole fan motor is designed for lowspeed, quieter, energy-saving operation.

� Non-cycling reversing valve and demand defrost.*Patented.

Page 2: Ruud UMPC Series Manual

U P M C 042 J A Z

RUUD HEAT PUMP REMOTEOUTDOOR

UNIT

DESIGNSERIES

ELECTRICALDESIGNATION

J = 208/230V 1ØC = 208/230V 3Ø

VARIATIONS

DESIGNVARIATIONS

A = 1ST DESIGN

COMPRESSORTYPE

Z = COPELAND SCROLLCOMPRESSORS

NOMINALCOOLINGCAPACITY

018 = 18,000 BTU/HR [5.28 kW]024 = 24,000 BTU/HR [7.03 kW]030 = 30,000 BTU/HR [8.79 kW]036 = 36,000 BTU/HR [10.55 kW]042 = 42,000 BTU/HR [21.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW]

All controls and compressor are accessiblefor servicing by removal of the service panel.

Drawn Painted Base Pan.

Model Number Identification

Engineering FeaturesUPMC- Series Heat Pump Outdoor Unit

1. Scroll Compressor—is hermetically sealed and incorporates internalhigh temperature motor overload protection, and durable insulation onthe motor windings. It is externally mounted on rubber grommets toreduce vibration and noise.

2. Copper Tube/Aluminum Fin Coils—Both indoor and outdoor coils.3. Strong, Attractive Cabinet—Constructed of powder painted steel.

Louvered design protects the coil from damage.4. Internal Check Valve—Provides for more quiet refrigerant metering.5. Refrigerant Metering—Expansion valves accurately meter refriger-

ant into indoor and outdoor coils.6. Manual Reset High Pressure Control—Deactivates system if

abnormally high pressure occurs.7. Drawn, painted base pan—for extra corrosion resistance and sound

reduction.8. Hard Start Components—Offer additional starting torque to cover

a wide range of voltage and pressure variations.9. PTC Self-Regulating Crankcase Heaters (only on 3 phase

models)—Conserve energy.10. Demand Defrost Control—Provides complete defrost when defrost

is required.11. Non-Cycling Reversing Valve—Eliminates discharge noises on

each heating cycle.12. Hot Gas Muffler—Reduces noise in heating cycle.13. Suction Line Accumulator—Provides protection for the compressor.14. Bi-Directional Filter Drier—Provided on all models.15. Service valves are standard on all models.

Convenience Features� The scroll compressor models (single phase only),

additionally have a 10 year compressor warranty asstandard.

� All refrigerant connections are on the exterior of the unit, located closeto the ground for neat appearing installations.

� Coil design permits compressor operation with the access panelremoved.

� Control box is fully accessible in the upper part of the cabinet, justunder the access panel.

� Power and control wiring are kept separate.� Every unit is factory charged and tested.

Accessories� Low Ambient Control—Allows low temperature operation in the

cooling cycle down to 0°F [-17.8°C] outdoor temperature. It isrecommended that this control be installed in units to be operated forcooling at outdoor ambient temperatures under 65°F [18°C]. (Model No. RXPZ-C01)

� Outdoor Thermostats—RXPT-A01—One outdoor thermostat in box.RXPT-A02—One outdoor thermostat for mounting in box RXPT-A01 or A03. RXPT-A03—One outdoor thermostat with emergency Heat Relaywired and mounted in box.RXPT-A04—Two outdoor thermostats with emergency Heat Relaywired and mounted in box.

� Heat Pump Monitor—Indicates inefficient operation or malfunction ofheat pump. (Model No. RXPM-B01)

� Thermostats and Subbases—Available through PROSTOCK™.� Compressor Time Delay Control—Compressor will remain off for

five minutes after power or thermostat interruption, allowing systempressures to equalize. Starting during high pressure conditions canresult in shortened compressor life. (Model No. RXMD-B01)

� Blower Time Delay Control—RXMD-C02.

[ ] Designates Metric Conversions2 Ruud Air Conditioning Division

Page 3: Ruud UMPC Series Manual

COPELAND® SCROLL®

COMPRESSORThe Copeland scroll compressor is the key to efficiency for this Ruudmodel. It’s the latest in high-efficiency compressor technology. Theadvanced scroll compressor offers low noise and vibrationcharacteristics and features tolerance to liquid refrigerant and systemcontamination. The Copeland Scroll also has low start torque,eliminating start problems in the field. And its unique design enables the UPMC- heat pump to perform efficiently, quietly and reliably.

This drawing is for illustrative purposes only. It is not intended to be used as an installation guide.

For all season home comfort, performance and energy conservation, choose a Ruud UPMC- Series Heat Pump and UBHK- SeriesAir Handler.

More than a reverse cycle air conditioner, it’s a specially designed combination Winter/Summer comfort system using an indoor coil forheating and cooling.

To choose an UBHK- Air Handler designed for use with the UPMC- Heat Pump, refer to the Performance Data Tables and/or the airhandler specification sheet.

Ruud Heat Pump System

Ruud Air Conditioning Division 3

Page 4: Ruud UMPC Series Manual

4 Ruud Air Conditioning Division

Model NumbersARI Cooling Performance

RCHA-24A1 (UBHC-14) 18,000[5.28]

12,900[3.78]

ARI Heating Performance (70°F [21°C] Indoor)

5,100[1.50] 12.2010.50 7.4 18,400

[5.39] 1,685 3.20 11,700[3.43] 1,517 2.26 8.25 7.15

80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35°C] DB Outdoor Air

RCHA-24A1 (UBHC-15) 18,000[5.28]

12,900[3.78]

5,100[1.50] 12.20

Outdoor Air47°F [8.5°C] DB/43°F [6°C] WB

DOE High Temp.

10.50 7.4

Outdoor Air17°F [–8.5°C] DB/15°F [–9.5°C] WBDOE Low Temp.

18,400[5.39] 1,685

DOERegion

IVHSPF

DOERegion

VHSPF

3.20 11,700[3.43] 1,517 2.26 8.25

OutdoorUnit

UPMC-

IndoorCoil and/orAir Handler

TotalCapacityBTU/H[kW]

NetSens.BTU/H[kW]

NetLatentBTU/H[kW]

7.15

EER SoundRating

RCHA-24A1 ➀18,000[5.28]

12,600[3.69]

5,400[1.59] 12.0010.50 7.4 18,200

[5.33]

BTU/H[kW]

TotalWatts COP BTU/H

[kW]TotalWatts COP

1,666 3.20018JA

RCBA-24**+RXCT-CHA18,000[5.28]

12,600[3.69]

5,400[1.59] 12.0010.50 7.4 18,200

[5.33] 1,666 3.20 11,200[3.28] 1,427 2.30 8.00 7.00

11,200[3.28]

RCBA-24**+RXCT-CHA (UBHC-14) 18,000[5.28]

12,900[3.78]

5,100[1.50] 12.20 7.4 18,400

[5.39] 1,685 3.20 11,700[3.43] 1,517 2.26 8.25 7.1510.50

1,427

RCBA-24**+RXCT-CHA (UBHC-15) 18,000[5.28]

12,900[3.78]

5,100[1.50] 12.2010.50 7.4 18,400

[5.39] 1,685 3.20 11,700[3.43] 1,517 2.26 8.25 7.15

2.30 8.00 7.00

SEER

RCHA-24A1 (UBHK-17) 18,500[5.42]

13,400[3.93]

5,100[1.50] 13.8511.85 7.4 17,900

[5.25] 1,533 3.42 11,200[3.28] 1,367 2.40 8.60 7.40

RCHA-24A1 (UGLL-05?BMK?) 18,500[5.42]

13,400[3.93]

5,100[1.50] 13.75 7.4 17,900

[5.25] 1,533 3.42 11,200[3.28] 1,379 2.38 8.60 7.4011.75

RCHA-24A2 (UBHC-14) 22,400[6.56]

16,400[4.81]

6,000[1.75] 12.0010.60 7.4 22,400

[6.56] 2,026 3.24 15,000[4.40] 1,980 2.22 7.90 7.20

RCHA-24A2 (UBHK-17) 22,600[6.62]

16,700[4.89]

5,900[1.73] 13.6511.95 7.4 21,800

[6.39] 1,846 3.46 14,300[4.19] 1,791 2.34 8.30 7.50

RCHA-24A2 ➀22,600[6.62]

16,200[4.75]

6,400[1.87] 12.0010.50 7.4 23,800

[6.98] 2,179 3.20024JA

RCBA-24**+RXCT-CHB22,600[6.62]

16,200[4.75]

6,400[1.87] 12.0010.50 7.4 23,800

[6.98] 2,179 3.20 14,800[4.34] 1,886 2.30 8.00 7.00

14,800[4.34]

RCBA-24**+RXCT-CHB (UBHC-14) 22,400[6.56]

16,400[4.81]

6,000[1.75] 12.00 7.4 22,400

[6.56] 2,026 3.24 15,000[4.40] 1,980 2.22 7.90 7.2010.60

1,886

RCBA-24**+RXCT-CHB (UBHC-15)22,400[6.56]

16,400[4.81]

6,000[1.75] 12.0010.60 7.4 22,400

[6.56] 2,026 3.24 15,000[4.40] 1,980 2.22 7.90 7.20

2.30 8.00 7.00

RCHA-36A1 (UBHC-17) 27,000[7.91]

19,600[5.74]

7,400[2.17] 12.1010.50 7.4 28,600

[8.38] 2,540 3.30

RCHA-24A2 (UGLL-05?BMK?) 23,200[6.80]

17,100[5.01]

6,100[1.79] 13.8012.05 7.4 21,800

[6.39] 1,835 3.48 14,300[4.19] 1,775 2.36 8.30 7.45

17,400[5.10]

RCBA-37**+RXCT-CHC (UBHC-17) 27,000[7.91]

19,600[5.74]

7,400[2.17] 12.10 7.4 28,600

[8.38] 2,540 3.30 17,400[5.10] 2,360 2.16 7.90 6.8510.50

2,360

RCHA-36A1 ➀27,200[7.97]

19,500[5.71]

7,700[2.26] 12.0010.50 7.4 28,400

[8.32] 2,485 3.34 17,600[5.16] 2,345 2.20 8.00 7.00

2.16 7.90 6.85

RCHA-24A1 (UGPL-05?BMK?) 18,500[5.42]

13,400[3.93]

5,100[1.50] 13.75 7.4 17,900

[5.25] 1,533 3.42 11,200[3.28] 1,379 2.38 8.60 7.4011.75

RCBA-37**+RXCT-CHC (UBHC-18) 27,000[7.91]

19,600[5.74]

7,400[2.17] 12.10 7.4 28,600

[8.38] 2,540 3.30 17,400[5.10] 2,360 2.16 7.90 6.8510.50

RCBA-37**+RXCT-CHC (UBHK-21) 27,600[8.09]

20,300[5.95]

7,300[2.14] 13.80 7.4 27,800

[8.15] 2,314 3.52 16,600[4.86] 2,133 2.28 8.30 7.1511.85

600[285]600

[285]

IndoorCFM[L/s]

600[285]

600[285]600

[285]600

[285]

600[285]600

[285]

800[380]

800[380]

800[380]

800[380]800

[380]800

[380]

1,000[470]

800[380]

1,000[470]

1,000[470]

600[285]

1,000[470]1,000[470]

RCBA-37**+RXCT-CHC 27,200[7.97]

19,500[5.71]

7,700[2.26] 12.0010.50 7.4 28,400

[8.32] 2,485 3.34 17,600[5.16] 2,345 2.20 8.00 7.001,000

[470]

RCGA-24A2 (UGPL-05?BMK?) 23,200[6.80]

17,100[5.01]

6,100[1.79] 13.7512.00 7.4 21,800

[6.39] 1,846 3.46 14,300[4.19] 1,775 2.36 8.30 7.45800

[380]

RCBA-24**+RXCT-CHA (UBHK-17) 18,500[5.42]

13,400[3.93]

5,100[1.50] 13.8511.85 7.4 17,900

[5.25] 1,533 3.42 11,200[3.28] 1,367 2.40 8.60 7.40600

[285]

RCBA-24**+RXCT-CHB (UBHK-17)22,600[6.62]

16,700[4.89]

5,900[1.73] 13.6511.95 7.4 21,800

[6.39] 1,846 3.46 14,300[4.19] 1,791 2.34 8.30 7.50800

[380]

RCHA-24A2 (UBHC-15) 22,400[6.56]

16,400[4.81]

6,000[1.75] 12.0010.60 7.4 22,400

[6.56] 2,026 3.24 15,000[4.40] 1,980 2.22 7.90 7.20800

[380]

RCHA-36A1 (UBHC-18) 27,000[7.91]

19,600[5.74]

7,400[2.17] 10.50 12.10 7.4 1,000

[470]28,600[8.38] 2,540 3.30 17,400

[5.10] 2,360 2.16 7.90 6.85

RCHA-36A1 (UBHK-21) 27,600[8.09]

20,300[5.95]

7,300[2.14] 11.85 13.80 7.4 1,000

[470]27,800[8.15] 2,314 3.52 16,600

[4.86] 2,133 2.28 8.30 7.15

RCHA-36A1 (UGLL-05?BMK?) 27,600[8.09]

20,200[5.92]

7,400[2.17] 11.70 13.65 7.4 1,000

[470]27,800[8.15] 2,327 3.50 16,700

[4.89] 2,165 2.26 8.20 7.05

RCHA-36A1 (UGLL-07?BRK?) 27,800[8.15]

20,400[5.98]

7,400[2.17] 11.80 13.70 7.4 1,000

[470]27,800[8.15] 2,314 3.52 16,700

[4.89] 2,146 2.28 8.20 7.10

030JA

Performance Data ARI Standard ConditionsNote: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.

➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions

Page 5: Ruud UMPC Series Manual

Ruud Air Conditioning Division 5

Model Numbers

RCHA-36A1 (UBHK-21)

ARI Cooling Performance

27,600[8.09]

20,300[5.95]

7,300[2.14]

ARI Heating Performance (70°F [21°C] Indoor)

13.8011.85

80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35°C] DB Outdoor Air

7.4

Outdoor Air47°F [8.5°C] DB/43°F [6°C] WB

DOE High Temp.

Outdoor Air17°F [–8.5°C] DB/15°F [–9.5°C] WBDOE Low Temp.

DOERegion

IVHSPF

DOERegion

VHSPF

OutdoorUnit

UPMC-

IndoorCoil and/orAir Handler

TotalCapacityBTU/H[kW]

NetSens.BTU/H[kW]

NetLatentBTU/H[kW]

27,800[8.15]

EER SoundRating

2,314 3.52 16,600[4.86] 2,133

RCHA-36A2 ➀ 33,400[9.79]

23,400[6.86]

10,000[2.93]

2.28

12.0010.50

8.30

7.6 35,800[10.49]

BTU/H[kW]

TotalWatts COP BTU/H

[kW]TotalWatts COP

3,180 3.30 23,200[6.80] 2,893 2.34

030JA

RCHA-36A1 (UGLL-07?BRQ?)27,400[8.03]

20,000[5.86]

7,400[2.17]

7.15

13.1511.30 7.4 28,200[8.26] 2,402 3.44 16,900

[4.95] 2,211 2.24 8.10 7.00

8.00 7.00

1,000[470]

1,200[565]

RCHA-36A2 (UBHK-21)

RCHA-36A1 (UGPL-07?BRK?)27,800[8.15]

20,400[5.98]

7,400[2.17]

33,400[9.79]

13.80

24,400[7.15]

7.4 27,800[8.15] 2,314 3.52 16,600

[4.86] 2,133 2.28 8.25 7.10

9,000[2.64]

11.85

13.4511.45 7.6

RCHA-36A1 (UGPL-07?BRQ?)27,600[8.09]

20,200[5.92]

7,400[2.17]

36,600[10.73]

13.4511.55 7.4 28,000[8.21] 2,358 3.48 16,800

[4.92] 2,178 2.26 8.20 7.05

3,118 3.44 23,200[6.80] 2,786 2.44 8.65 7.501,200

[565]

RCHA-36A2 (UBHC-18)33,000[9.67]

23,900[7.00]

9,100[2.67] 12.0010.35 7.6 37,400

[10.96] 3,362 3.26 24,000[7.03] 3,031 2.32 8.20 7.15

RCHA-36A2 (UGLL-05?BMK?)33,800[9.91]

24,700[7.24]

9,100[2.67] 13.2511.30 7.6 36,800

[10.79] 3,153 3.42 23,200[6.80] 2,809 2.42 8.60 7.45

RCHA-36A2 (UBHC-17)33,000[9.67]

23,900[7.00]

9,100[2.67] 12.0010.35 7.6 37,400

[10.96] 3,362 3.26

036CA/JA

RCBA-37**+RXCT-CHK33,400[9.79]

23,400[6.86]

10,000[2.93] 12.0010.50 7.6 35,800

[10.49]

SEER

3,180 3.30 23,200[6.80] 2,893 2.34 8.00 7.00

24,000[7.03]

RCBA-37**+RXCT-CHK (UBHC-17)33,000[9.67]

23,900[7.00]

9,100[2.67] 12.00 7.6 37,400

[10.96] 3,362 3.26 24,000[7.03] 3,031 2.32 8.20 7.1510.35

3,031

RCBA-37**+RXCT-CHK (UBHC-18)33,000[9.67]

23,900[7.00]

9,100[2.67] 12.0010.35 7.6 37,400

[10.96] 3,362 3.26 24,000[7.03] 3,031 2.32 8.20 7.15

2.32 8.20 7.15

RCHA-36A2 (UGLL-07?BRK?)33,800[9.91]

24,700[7.24]

9,100[2.67] 13.3511.40 7.6 36,600

[10.73] 3,136 3.42 23,200[6.80] 2,786 2.44 8.60 7.45

IndoorCFM[L/s]

1,000[470]

1,000[470]1,000[470]

1,200[565]

1,200[565]

1,200[565]

1,200[565]1,200[565]1,200[565]

1,200[565]

RCHA-36A2 (UGLL-07?BRQ?)33,200[9.73]

24,100[7.06]

9,100[2.67] 12.4010.85 7.6 37,200

[10.90] 3,303 3.30 23,800[6.98] 2,955 2.36 8.35 7.301,200

[565]

RCHA-36A1 (UGPL-05?BMK?)27,600[8.09]

20,200[5.92]

7,400[2.17] 13.5511.65 7.4 28,000

[8.21] 2,344 3.50 16,700[4.89] 2,165 2.26 8.20 7.051,000

[470]

RCBA-37**+RXCT-CHK (UBHK-21)33,400[9.79]

24,000[7.15]

9,000[2.64] 13.4511.45 7.6 36,600

[10.73] 3,118 3.44 23,200[6.80] 2,786 2.44 8.65 7.501,200

[565]

RCHA-36A2 (UGLL-10?BRM?)33,800[9.91]

24,700[7.24]

9,100[2.67] 11.35 13.30 7.6 1,200

[565]36,600[10.73] 3,136 3.42 23,200

[6.80] 2,786 2.44 8.60 7.45

RCHA-36A2 (UGPL-05?BMK?)33,600[9.85]

24,500[7.18]

9,100[2.67] 11.10 13.00 7.6 1,200

[565]36,800[10.79] 3,190 3.38 23,400

[6.86] 2,857 2.40 8.50 7.40

RCHA-36A2 (UGPL-07?BRK?)33,800[9.91]

24,700[7.24]

9,100[2.67] 11.35 13.35 7.6 1,200

[565]36,600[10.73] 3,136 3.42 23,200

[6.80] 2,786 2.44 8.60 7.45

RCHA-36A2 (UGPL-07?BRQ?)33,600[9.85]

24,500[7.18]

9,100[2.67] 11.15 13.05 7.6 1,200

[565]36,800[10.79] 3,190 3.38 23,400

[6.86] 2,833 2.42 8.55 7.40

RCHA-36A2 (UGPL-10?BRM?)33,600[9.85]

24,500[7.18]

9,100[2.67] 11.15 13.05 7.6 1,200

[565]36,800[10.79] 3,190 3.38 23,400

[6.86] 2,857 2.40 8.50 7.40

RCHA-36A2 (UBHK-21)34,400[10.08]

25,100[7.36]

9,300[2.72] 11.50 13.60 7.6 1,200

[565]36,600[10.73] 3,118 3.44 23,200

[6.80] 2,786 2.44 8.65 7.50

042CA/JA

RCBA-60**+RXCT-CHE 41,000[12.02]

29,000[8.50]

12,000[3.52] 10.35 12.00 7.8 1,400

[660]43,000[12.60] 3,866 3.26 27,400

[8.03] 3,461 2.32 8.05 7.00

RCBA-60**+RXCT-CHE (UBHK-24) 41,000[12.02]

29,300[8.59]

11,700[3.43] 11.40 13.15 7.8 1,400

[660]42,000[12.31] 3,457 3.56 27,000

[7.91] 3,165 2.50 8.65 7.50

RCHJ-48A1 ➀41,000[12.02]

29,000[8.50]

12,000[3.52] 10.35 12.00 7.8 1,400

[660]43,000[12.60] 3,866 3.26 27,400

[8.03] 3,461 2.32 8.05 7.00

RCHJ-48A1 (UBHK-24)41,000[12.02]

29,300[8.59]

11,700[3.43] 11.40 13.15 7.8 1,400

[660]42,000[12.31] 3,457 3.56 27,000

[7.91] 3,165 2.50 8.65 7.50

RCHJ-48A1 (UGLL-07?BRQ?)40,500[11.87]

28,700[8.41]

11,800[3.46] 10.65 12.20 7.8 1,400

[660]43,000[12.60] 3,684 3.42 27,800

[8.15] 3,394 2.40 8.35 7.35

RCHJ-48A1 (UGLL-10?BRM?)41,000[12.02]

29,200[8.56]

11,800[3.46] 11.20 12.85 7.8 1,400

[660]42,500[12.46] 3,538 3.52 27,200

[7.97] 3,240 2.46 8.55 7.45

RCHJ-48A1 (UGLL-12?ARM?)41,500[12.16]

29,500[8.65]

12,000[3.52] 10.65 12.40 7.8 1,400

[660]42,500[12.46] 3,729 3.34 26,800

[7.85] 3,386 2.32 8.00 6.00

RCHJ-48A1 (UGPL-07?BRQ?)40,500[11.87]

28,800[8.44]

11,700[3.43] 10.90 12.50 7.8 1,400

[660]42,500[12.46] 3,600 3.46 27,400

[8.03] 3,291 2.44 8.45 7.40

➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions

Performance Data ARI Standard Conditions (cont.)Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.

Page 6: Ruud UMPC Series Manual

6 Ruud Air Conditioning Division

Model NumbersARI Cooling Performance ARI Heating Performance (70°F [21°C] Indoor)

80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35°C] DB Outdoor Air

Outdoor Air47°F [8.5°C] DB/43°F [6°C] WB

DOE High Temp.

Outdoor Air17°F [–8.5°C] DB/15°F [–9.5°C] WBDOE Low Temp.

DOERegion

IVHSPF

DOERegion

VHSPF

OutdoorUnit

UPMC-

IndoorCoil and/orAir Handler

TotalCapacityBTU/H[kW]

NetSens.BTU/H[kW]

NetLatentBTU/H[kW]

EER SoundRating

RCHJ-48A2 (UBHK-24)47,000[13.77]

34,200[10.02]

12,800[3.75] 13.2011.45 7.8 47,500

[13.92]

BTU/H[kW]

TotalWatts COP BTU/H

[kW]TotalWatts COP

3,867 3.60 30,600[8.97] 3,423 2.62

042CA/JARCHJ-48A1 (UGPL-10?BRM?)

40,500[11.87]

28,800[8.44]

11,700[3.43] 12.6511.05 7.8 42,500

[12.46] 3,579 3.48 27,400[8.03] 3,291 2.44 8.50 7.40

8.80 8.151,600[755]

RCHJ-48A2 (UGLL-12?ARM?)

RCHJ-48A1 (UGPL-12?ARM?)41,000[12.02]

29,300[8.59]

11,700[3.43]

46,500[13.63]

12.95

33,700[9.88]

7.8 42,500[12.46] 3,518 3.54 27,200

[7.97] 3,214 2.48 8.60 7.45

12,800[3.75]

11.30

12.4510.85 7.8 48,000[14.07] 4,019 3.50 31,200

[9.14] 3,600 2.54 8.65 7.901,600[755]

RCHJ-48A2 (UGLL-10?BRM?)46,500[13.63]

33,200[9.73]

13,300[3.90] 12.2010.75 7.8 48,000

[14.07] 4,212 3.34 30,400[8.91] 3,535 2.52 8.40 7.40

RCHJ-48A2 (UGPL-07?BRQ?)46,500[13.63]

33,700[9.88]

12,800[3.75] 12.3510.75 7.8 48,000

[14.07] 4,042 3.48 31,400[9.20] 3,651 2.52 8.60 7.90

RCHJ-48A2 (UGLL-07?BRQ?)46,000[13.48]

33,300[9.76]

12,700[3.72] 12.0010.50 7.8 48,500

[14.21] 4,156 3.42048CA/JA

RCBA-60**+RXCT-CHH46,500[13.63]

33,200[9.73]

13,300[3.90] 12.0010.65 7.8 48,500

[14.21]

SEER

4,208 3.38 31,000[9.09] 3,541 2.58 8.35 7.10

31,600[9.26]

RCBA-60**+RXCT-CHH (UBHK-24)47,000[13.77]

34,200[10.02]

12,800[3.75] 13.20 7.8 47,500

[13.92] 3,867 3.60 30,600[8.97] 3,423 2.62 8.80 8.1511.45

3,734

RCHJ-48A2 ➀ 46,500[13.63]

33,200[9.73]

13,300[3.90] 12.0010.65 7.8 48,500

[14.21] 4,208 3.38 31,000[9.09] 3,541 2.58 8.35 7.10

060CA/JA

2.48 8.50 7.80

RCHJ-48A2 (UGPL-10?BRM?)46,500[13.63]

33,700[9.88]

12,800[3.75] 12.5010.90 7.8 48,000

[14.07] 4,019 3.50 31,200[9.14] 3,600 2.54 8.65 7.90

RCBA-60**+RXCT-CHJ (UBHK-25) 53,000[15.53]

38,100[11.17]

14,900[4.36] 13.00 7.8 53,500

[15.68] 4,479 3.50 35,400[10.37] 4,183 2.48 8.35 7.4011.00

IndoorCFM[L/s]

1,400[660]1,400[660]

1,600[755]

1,600[755]

1,600[755]

1,600[755]1,600[755]1,600[755]

1,600[755]

1,950[920]1,950[920]1,950[920]

RCHJ-60A1 ➀ 52,500[15.39]

37,400[10.96]

15,100[4.43] 12.00 7.8 58,000

[17.00] 5,247 3.24 36,200[10.61] 4,653 2.28 7.90 6.8510.00

RCHJ-60A1 (UBHK-25) 53,000[15.53]

38,100[11.17]

14,900[4.36] 13.00 7.8 53,500

[15.68] 4,479 3.50 35,400[10.37] 4,183 2.48 8.35 7.4011.00

RCBA-60**+RXCT-CHJ 52,500[15.39]

37,400[10.96]

15,100[4.43] 12.0010.00 7.8 58,000

[17.00] 5,247 3.24 36,200[10.61] 4,653 2.28 7.90 6.851,950

[920]

RCHJ-48A2 (UGPL-12?ARM?)47,000[13.77]

34,200[10.02]

12,800[3.75] 12.9011.20 7.8 47,500

[13.92] 3,910 3.56 30,800[9.03] 3,498 2.58 8.70 8.001,600

[755]

Performance Data ARI Standard Conditions (cont.)Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.

➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTYRuud will furnish a replacement for any part of this productwhich fails in normal use and service within the applicableperiods stated, in accordance with the terms of the limited warranty.For Complete Details of the Limited Warranty, Including Applicable Termsand Conditions, See Your Local Installer or Contact the Manufacturer fora Copy.

Condenser Coil leaks caused byfactory defects..........................................Five (5) Years

Compressor—Three Phase Models ................Five (5) YearsCompressor—Single Phase Models ..............Ten (10) Years*Any Other Part ..........................................Five (5) Years*This five year limited warranty is applicable only to single-phase productsinstalled in residential applications on or after January 1, 2001.

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCYINFORMATION AVAILABLE FROM YOUR RETAILER.

Page 7: Ruud UMPC Series Manual

Ruud Air Conditioning Division 7

Model NumberUPMC-

Height “H”(Inches) [mm]

Length “L”(Inches) [mm]

Width “W”(Inches) [mm]

018 203/4 [527] 3811/16 [903] 271/8 [689]024/030/036 263/4 [539] 429/16 [1082] 31 [787]

060 343/4 [883] 439/16 [1092] 31 [787]042/048 263/4 [539] 429/16 [1082] 31 [787]

ModelNumberUPMC-

ELECTRICAL PHYSICAL

PhaseFrequency (Hz)Voltage (Volts)

Compressor Fan MotorFull LoadAmperes

(FLA)

MinimumCircuit

AmpacityAmperes

Fuse or HACRCircuit Breaker Outdoor Coil

R22Oz. [g]

WeightRated Load

Amperes(RLA)

Locked RotorAmperes

(LRA)MinimumAmperes

MaximumAmperes

Face AreaSq. Ft. [m2]

No.Rows CFM [L/s] Net

Lbs. [kg]ShippingLbs. [kg]

030JA 1-60-208-230 12.2/12.2 67 1.3 17/17 15/15 25/25 17.3 [1.607] 1 2950 [1392] 133 [3770] 215 [97.5] 225 [102.1]

018JA 1-60-208-230 9.6/9.6 44.9 .9 13/13 15/15 20/20 11.0 [1.022] 1 2310 [1090] 85 [2410] 170 [77.1] 180 [81.6]024JA 1-60-208-230 10.9/10.9 54 1.5 15/15 15/15 25/25 17.3 [1.607] 1 2950 [1392] 115 [3260] 210 [95.3] 220 [99.8]

036CA 3-60-208-230 12.1/12.1 77 2.0 18/18 15/15 25/25 17.3 [1.607] 2 3800 [1793] 200 [5670] 245 [111.1] 255 [115.7]036JA 1-60-208-230 16.5/16.5 88 2.0 23/23 25/25 35/35 17.3 [1.607] 2 3800 [1793] 200 [5670] 245 [111.1] 255 [115.7]

060JA 1-60-208-230 26.2/26.2 169 2.0 35/35 45/45 60/60 23.0 [2.137] 2 3700 [1746] 242 [6861] 305 [138.3] 315 [142.9]060CA 3-60-208-230 18.4/18.4 123 2.0 25/25 30/30 40/40 23.0 [2.137] 2 3700 [1746] 242 [6861] 305 [138.3] 315 [142.9]

048CA 3-60-208-230 13.7/13.7 91 2.0 20/20 25/25 30/30 17.3 [1.607] 2 3750 [1770] 214 [6067] 262 [118.8] 272 [123.4]

042CA 3-60-208-230 12.6/12.6 88 2.0 18/18 25/25 30/30 17.3 [1.607] 2 3800 [1793] 214 [6067] 222 [100.7] 232 [105.2]042JA 1-60-208-230 18.6/18.6 109 2.0 26/26 30/30 40/40 17.3 [1.607] 2 3800 [1793] 214 [6067] 222 [100.7] 232 [105.2]

048JA 1-60-208-230 19.9/19.9 137 2.0 27/27 35/35 45/45 17.3 [1.607] 2 3750 [1770] 214 [6067] 262 [118.8] 272 [123.4]

Unit Dimensions

[ ] Designates Metric Conversions

Electrical and Physical Data

Page 8: Ruud UMPC Series Manual

Vapor Line Length/Size versus Capacity Multiplier

Vapor Line Run—Feet [m]

11/8" [28.58 mm] I.D. Sweat*7/8" [22.23 mm] I.D. Sweat

OptionalStandardOptionalOptionalStandardOptional

Unit Vapor Line Connection Size

OptionalStandardOptional

3/4" [19.05 mm] I.D. Sweat

OptionalStandardOptional

060048042036030024UPMC- 018

5/8" [15.88 mm] O.D. Optional3/4" [19.05 mm] O.D. Standard7/8" [22.23 mm] O.D. Optional

3/4" [19.05 mm] O.D. Optional7/8" [22.23 mm] O.D. Standard11/8" [28.58 mm] O.D. Optional

7/8" [22.23 mm] O.D. Optional11/8" [28.58 mm] O.D. Standard13/8" [34.93 mm] O.D. Optional

25' [7.62].98

1.001.01

0.981.001.01

—1.001.01

.991.001.01

—1.001.01

0.991.001.01

0.991.001.01

50' [15.24]0.960.991.00

.960.991.00

—0.991.00

.970.991.01

—0.991.01

0.971.001.01

0.970.991.01

100' [30.48]0.930.991.00

0.930.980.99

—0.970.99

.930.981.00

—0.981.00

0.960.991.00

0.950.991.00

150' [45.72]—

0.981.00

—0.970.98

—0.950.97

—0.970.99

—0.960.99

0.930.991.00

0.930.980.99

SystemCapacity

Tons[kW]

LineSize

(Inch O.D.)[mm]

Liquid Line SizeOutdoor Unit Above Indoor Coil

Liquid Line SizeOutdoor Unit Below Indoor Coil

Total Length—Feet [m] Total Length—Feet [m]25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72]

Vertical Separation—Feet [m]

1.5 [5.28]1/4* [6.35] 25 [7.62] 50 [15.24] 70 [21.34] 25 [7.62] 23 [7.01] 8 [2.44]

5/16 [7.94] 36 [10.97] 42 [12.80] 48 [14.63] 54 [16.46] 36 [10.97] 30 [9.14] 24 [7.32] 18 [5.49]

5/16 [7.94] 24 [7.32] 34 [10.36] 44 [13.41] 54 [16.46] 64 [19.51] 48 [14.63] 38 [11.58] 28 [8.53] 18 [5.49] 8 [2.44]2 [7.03]

1/4* [6.35] 25 [7.62] 50 [15.24] 25 [7.62] 23 [7.01]

5/16 [7.94] 19 [5.79] 33 [10.06] 47 [14.33] 61 [18.59] 50 [15.24] 39 [11.89] 25 [7.62] 11 [3.35]

3 [10.55]5/16* [7.94] 25 [7.62] 50 [15.24] 70 [21.34] 25 [7.62] 23 [7.01] 9 [2.74]

3/8 [9.53] 11 [3.35] 15 [4.57]2.5 [8.79]

1/4* [6.35] 25 [7.62] 50 [15.24] 25 [7.62] 23 [7.01]

57 [17.37]

3/8 [9.53] 34 [10.36] 40 [12.19] 46 [14.02] 52 [15.85] 38 [11.58] 32 [9.75] 26 [7.92] 20 [6.10]

3/8 [9.53] 32 [9.75] 39 [11.89] 46 [14.02] 53 [16.15] 40 [12.19] 33 [10.06] 26 [7.92] 19 [5.79]3.5 [12.30]

5/16* [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 25 [7.62] 23 [7.01] 9 [2.74]

1/2 [12.7] 37 [11.28] 39 [11.89] 35 [10.67] 33 [10.06]

1/2 [12.7] 35 [10.67] 38 [11.58] 41 [12.50] 37 [11.28] 34 [10.36] 31 [9.45]5 [17.58]

3/8* [9.53] 25 [7.62] 48 [14.63] 61 [18.59] 72 [21.95]

4 [14.06]3/8* [9.53] 25 [7.62] 44 [13.41] 53 [16.15] 61 [18.59] 70 [21.34] 25 [7.62] 28 [8.53] 19 [5.79] 11 [3.35] 3 [.91]

25 [7.62] 23 [7.01] 11 [3.35] 3 [.91]

*Standard line sizeNOTES:➀ This chart is applicable for heat pumps.➁ If the separation height exceeds the table values, increase the outdoor flow-check piston two sizes plus one

size for each additional 10 feet [3.05 m].Example 1: A 5 ton [17.58 kW] heat pump with a total line length of 100 feet [30.48 m] with a verticalseparation of 93 feet [28.35 m] utilizing a 3/8" [9.53 mm] liquid line: Table = 72 feet [21.95 m] maximumvertical separation for 100 feet [30.48 m] run. Separation exceeds table by (93-72) = 21 feet [6.40 m].Therefore, reduce the indoor coil flow-check piston 2 + 2 = 4 sizes (For example, a #89 piston would reduceto a #85 piston). Increase the outdoor flow-check piston 2 + 2 = 4 sizes (For example, a #56 would increaseto a #60).

➂ Do not exceed 120 feet [36.58 m] maximum vertical separation.➃ No changes are required for expansion valve coils.➄ Do not exceed table values for capillary tube coils.➅ Always use the smallest liquid line possible to minimize system charge.➆ For heat pumps with vertical separation: • Route liquid line outside building • Do not insulate liquid line.➇ Chart may be used to size horizontal runs.

NOTES:➀ This chart is applicable for heat pumps. Heat pumps with any vertical

separation require the use of standard line sizes only, due to the possibility ofcharge imbalance between heating and cooling modes.Example 1: A 3 ton [10.55 kW] heat pump with a total line length of 50 feet[15.24 m] can have a maximum vertical separation of 19 feet [5.79 m]. Do notincrease line size to 3/8" [9.53 mm].

➁ This chart may also be used to size horizontal runs.Example 2: A 1.5 ton [5.28 kW] heat pump can have a total horizontal linelength of 150 feet [45.72 m] when using the 5/16" [7.94 mm] liquid line size.No vertical separation allowed.

➂ Do not exceed vertical separation as indicated on the chart.➃ Always use the smallest liquid line possible to minimize system charge.➄ No changes required for flow-check pistons or expansion valve coils.

Vertical Separation—Feet [m]

NOTES: Capacity Multiplier x Rated Capacity = Actual Capacity.Additional compressor oil is not required for runs up to 150 feet [45.72 m].Oil traps in vertical runs are not required for any height up to 125 feet [38.10 m]. See Liquid Line chart for Vertical Separation Requirements and Limitations.*Adapter to 11/8" [28.58 mm] factory supplied.

[ ] Designates Metric Conversions

Heat Pump Refrigerant Line Size Information

Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices.

RUUDAIR CONDITIONINGDIVISION

5600 Old Greenwood Road, Fort Smith, Arkansas 72908

“In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.”

PRINTED IN U.S.A. 4-02 DC FORM NO. P22-743 REV. 3Supersedes Form No. P22-743 Rev. 2