rss - nioec. راحي سيستم هاي اعلام... · pdf file12-15,2000,in...

20
rss 22921500-0912.245.1159 STD.NFPA 121-ENGL 2001 .. 6474446 0595576 579 .. Copyright by the National Fire Protection Association Tue Feb 09 14:53:58 2010

Upload: dinhtruc

Post on 06-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

rss 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595576 579 ..

Copyright by the National Fire Protection AssociationTue Feb 09 14:53:58 2010

Page 2: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595577 405 ..

IMPORTANT NOTICE ABOUT THIS DOCUMENT

NFPA codes, standards, recommended practices, and guides, of which the document contained herein is one,are developed through a consensus standards development process approved by the American National StandardsInstitute. This process brings together volunteers representing varied viewpoints and interests to achieveconsensus on fire and other safety issues. While the NFPA administers the process and establishes rules topromote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracyof any information or the soundness of any judgments contained in its codes and standards.

The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever,whether special. indirect, consequential or compensatory, directly or indirectly resulting from the publication, useof, or reliance on this document. The NFPA also makes no guaranty or warranty as to the accuracy orcompleteness of any information published herein.

In issuing and making this document available, the NFPA is not undertaking to render professional or otherservices for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by anyperson or entity to someone else. Anyone using this document should rely on his or her own independentjudgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonablecare in any given circumstances.

The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of thisdocument. Nor does the NFPA list, certify, test or inspect products. designs, or installations for compliance withthis document. Any certification or other statement of compliance with the requirements of this document shallnot be attributable to the NFPA and is solely the responsibility of the certifier or maker of the statement.

See insidebackcoverfor additional important noticesand information.

8/00

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:08 2010

Page 3: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 647444h 0595578 341 ..

Copyright © 2001 NFPA,All Rights Reserved

NFPA 121

Standard on

Fire Protection for Self-Propelledand Mobile Surface Mining Equipment

2001 Edition

This edition ofNFPA 121, Standard onFireProtection for Self-Propelled and Mobilt Surface Min­ing Equipment, was prepared by the Technical Committee on Mining Facilities and acted onby the National Fire Protection Association, Inc., at its November Meeting held November12-15,2000, in Orlando, FL. Itwas issued by the Standards Council onjanuary 13, 200l. withan effective date ofFebruary 9,2001, and supersedes all previous editions.

This edition ofNFPA 121wasapproved asan American National Standardon February 9,2001.

Origin and Development of NFPA 121

The Mining Facilities Committee was formed in 1977 to fulfill the need for consensus firesafety for mining. The task of developing the draft of this standard was assigned to the Sub­committee on Surface Mining. It wassubmitted to the Technical Committee on Mining Facil­ities for release to the Association and was issued in 1981 as a first edition. The next editionfollowed in 1986 and included a tide change to verify that it includes self-propelled miningequipment. In addition it added a provision for a hazard analysis on each piece of miningequipment. The 1990 edition introduced a variety of minor changes, including the replace­ment of the term hazard anarysis with fire risk assessment throughout the document. The 1996edition of the standard was a reconfirmed version of the 1990 edition with editorial correc­tions and changes to conform to the NFPA Manual ofStyle.

The 2001 edition of the standard clarifies that fire alarm systems must meet the require­ments of NFPA 72, National Fwe Alarm Co~. The definitions also have been updated to con­form to the NFPAGlossaryofTerrns.

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:10 2010

1%1-1

Page 4: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595579 288 ..

121-2 FIRE PROTECTION FOR SELF·PROPELLED AND MOBILE SURFACE MINING EQUIPMENT

Technical Committee on Mining Facilities

Larry J. Moore, ChairFM Global, CO [I]

William R. Bragg, Levitt safety (Eastern) Ltd, Canada [M]Rep. Fire Equipment Mfrs. Inst, of Canada

Dennis Duane Brohmer, Ansul Inc./Tyco Int'I, WI [M]Byron G. Brumbaugh, ASARCO Inc., UT [U]MatthewJ. Bujewski, Marsh USA, Inc., MO [I]Michael C. Diliberto, Diliberto & Assoc., Inc., CO [SE]Richard A. Dressler, Bucyrus-Erie Co., WI [M]Tim Gierer, Alltypc Fire Protection ce, MO [1M]

Rep. Nat'l Assn. of Fire Equipment Distributors Inc.Howard R. Healey, Marsh USA Inc., IL [I]Will B.Jamison, Consulting Engr, PA [SE]

J.J. Kenny, Marsh USA, Inc., Canada [I](Alt. to M.J. Bujewski)

Richard P. Bielen, NFPA Staff Liaison

Alternates

Thomas Kaylor, Chubb Group of Insurance Cos.,KY [I]Vincent A. Lupo, DBA: Firernaster (Master ProtectionCorp.), CO [1M]James W. McCollum, Caterpillar Inc .. IL [M]Donald C. McConnell, Cyprus Amax Coal Co.. IL [U]Barry A. Stewart, Science Applications Int'l Corp. (SAlC).NV[SEjBruce Watzman, Nat'l Mining Assn., DC [UjRobert A. Wessel, Gypsum Assn., DC [M]

David A. Pelton, Ansul Inc./Tyco Int'l, IL [M](Alt. to D. D. Brohmer)

This list represents the membership at the time the Committee was balloted on the final text of this edition. Since thattime, changes in the membership may have occurred. A key to classifications is found at the back ofthe document:

NOTE: Membership on a committee shall not in and of itself constitute an endorsement of the Associationor any document developed by the committee on which the member serves.

Committee Scope: This Committee shal! have primary responsibility for documents on safeguarding life andproperty against fire, explosion, and related hazards associated wi th underground and surface coal and met­al and nonmetal mining facilities and equipment.

2001 Ed~ion

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:10 2010

Page 5: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595580 TTT ..

CONTENTS

Contents

121-3

~terl Introduction 121- 4

1.1 Scope 121- 4

1.2 Purpose 121- 4

1.3 Definitions 121- 4

~ter 2 YlI'e Protection. . . . . .. . . . . .. .. .. .. 121- 5

2.1 Fire Protection 121- 5

2.2 Fire Risk Assessment 121- 5

2.3 Risk Reduction 121- 5

2.4 Fire Detection and SuppressionEquipment 121- 6

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:10 2010

Chapter 11 Referenced Publications. . . . . . . . . . . . .. 121- 7

Appendix A Explanatory Material. . . . . . . . . . . . . .. 121- 7

Appendix B Fire Risk Assessment 121- 8

Appendix C Suggested References 121-11

Appendix D Referenced Publications 121-12

Index 121-13

2001 Edftlon

Page 6: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595581 936 ..

121-4 FIRE PROTECTION FOR SELF-PROPELLED AND MOBILE SURFACE MINING EQUIPMENT

NFPA 121

Standard on

Fire Protection for Self-Propelledand Mobile Surface Mining Equipment

2001 Edition

NOTICE: An asterisk (0) following the number or letter des­ignating a paragraph indicates that explanatory material onthe paragraph can be found in Appendix A.

Changes other than editorial are indicated by a vertical rulein the margin of the pages on which they appear. These linesare included as an aid to the user in identifying changes fromthe previous edition.

A reference in parentheses ( ) following a section or para­graph indicates material that has been extracted from anotherNFPA document. The complete title and edition of the docu­ment the material is extracted from is found in Chapter 3. Edi­torial changes to extracted material consist of revisingreferences to an appropriate division in this document or theinclusion of the document number with the division numberwhen the reference is to the original document. Requests forinterpretations or revisions ofextracted text shall be sent to theappropriate technical committee.

Information on referenced publications can be found inChapter 3 and Appendix D.

Chapter 1 Introduction

1.1* Scope. This standard covers minimum requirementsfor safeguarding life and property against fire and relatedhazards associated with self-propelled and mobile surfacemining equipment.

1.2 Purpose. This standard is for the use of those chargedwith mine fire prevention and protection and with the respon­sibility for purchasing, designing, installing, testing, inspect­ing, approving, listing, operating, or maintaining both minefire protection equipment and self-propelled and mobile sur­face mining equipment.

1.2.1 At times it will be necessary for those charged with pur­chasing, testing, approving, and maintaining fire protectionequipment for self-propelled and surface mining equipmentto consult an experienced fire protection specialist.

1.2.2 Because of the uniqueness ofsurface mining, provisionsin this standard can differ from commonly accepted fire pro­tection standards and guides for other types of occupancies.

1.2.3 Nothing in this standard is intended to prevent the useofsystems, methods, or devices of equivalent or superior qual.ity, strength, fire resistance, effectiveness, durability, andsafety over those prescribed by this standard, providing techni­cal documentation is submitted to the authority havingjuris­diction to demonstrate equivalency and the system, method,or device is approved for the intended purpose.

1.2.4 The provisions of this standard are considered necessaryto provide a reasonable degree ofprotection from the hazardsaddressed in this standard. They reflect situations and thestate of the art at the time the standard was issued.

Unless otherwise noted, the provisions of this standardshall not apply to facilities, equipment, structures, or installa­tions that existed or were approved for construction or instal-

2001 Edition

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:11 2010

lation prior to the effective date of the standard. Where noted,the provisions of this standard shall be ret.roactive.

In those cases where the authority having jurisdictiondetermines that the existing situation involves a distinct haz­ard, the aut.hority having jurisdiction shall be permitted toapply retroactively any portions of this standard that he or shedeems appropriate.

1.3 Deflaftions, The definitions used in this standard are inaccordance with general mining industry usage or dictio­nary definitions.

1.3.1* Approved. Acceptable to the authority havingjurisdic­tion.

1.3.2* Authority Havingjurisdiction. The organization, office,or individual responsible for approving equipment, materials,an installation, or a procedure.

1.3.3 Combustible. Capable of undergoing combustion.

1.3.4 Combustion. A chemical process of oxidation thatoccurs at a rate fast enough to produce heat and usually lightin the form of either a glow or flame.

1.3.5 Emergency Egress. An egress from a compartment orwork station in emergencies when the normal egress is unusable.

1.3.6 Equipment Operator. The authorized person whostarts, controls, or stops mining equipment.

1.3.7 Fire Risk Assessment. The evaluation of the relativedanger of the start and spread of fire; the generation ofsmoke, gases, or toxic fumes; and the possibility of explosionor other occurrence endangering the lives and safety of per­sonnel or causing significant damage to property.

1.3.8 Fixed Suppression System. A total flooding or localapplication system that consists of a fixed supply ofextinguish­ing agent permanently connected to fixed piping with fixednozzles that are arranged to discharge an extinguishing agentinto an enclosure (total flooding) or directly onto a fire (localapplication), or a combination of both.

1.3.9 Flash Point. The minimum temperature of a liquid atwhich sufficient vapor is given off to form an ignitible mixturewith the air, near the surface of the liquid or within the vesselused, as determined by the appropriate test procedure andapparatus specified in NFPA 30, Flammable and Combustible Liq­uids Code,1.7.4. (30:1.7.2.2)

1.3.10 Labeled. Equipment or materials to which has beenattached a label, symbol, or other identifying mark of an orga­nization that is acceptable to the authority havingjurisdictionand concerned with product evaluation, that maintains peri­odic inspection of production of labeled equipment or mate­rials, and by whose labeling the manufacturer indicatescompliance with appropriate standards or performance in aspecified manner.

1.3.11 liqUid

1.3.11.1 Combustible Liquid Any liquid that has a closed­cup flash point at or above 100°1' (37.8°C), as determined bythe test procedures and apparatus set forth in NFPA 30, Flam­mable and Combustible Liquids Code, 1.7.4. Combustible liquidsare classified as Class II or Class ill as follows: (a) Class IILiquid- any liquid that has a flash point at or above 100°F (37.8°C)and below 140°F (60°C); (b) Class lIlA - any liquid that has aflash point at or above 140°F (60°C), but below 200"F (93°C);(c) Class IIIB - any liquid that has a flash point at or above2()()OF (93°C). (30:1.7.3.1)

Page 7: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 II 6474446 0595582 872 II

FIRE PROTECTION 121-5

1.3.11.2 Flammable liquid. Any liquid that has a closed-cupflash point below 100°F (37.8°C),as determined by the test pr~cedures and apparatus set forth in NFPA3O,Flmnmableand C0m­bustible Liquids Code, 1.7.4. Flammable liquids are classified asClass I as follows: (a) Class I Liquid - any liquid that has aclosed-cup flash point below 100°F (37.8°C) and a Reid vaporpressure not exceeding 40 psia (2068.6 mm Hg) at looOf'(37.8°C), as determined byASTMD 323, StandardMetlwd ofTestfor vapor Pressure 0/Petroleum Products (Reid Method). Class I liq­uids are further classified as follows: (1) Class IA liquids- thoseliquids that have flash points below 73°F (22.8°C) and boilingpoints below lOOOf' (37.S°C); (2) Class Ib liquids - those liquidsthat have flash points below 73°F (22.8°C) and boiling points ator above lOO°F (37.8°C); (3) ClassICliquids- those liquids thathave flash points at or above 73°F (22.8°C), but below looOf'(37.8°C). (30:1.7.3.2)

1.3.12* Listed. Equipment, materials, or services included ina list published by an organization that is acceptable to theauthority having jurisdiction and concerned with evaluationof products or services, that maintains periodic inspection ofproduction of listed equipment or materials or periodic eval­uation of services, and whose listing states that either theequipment, material, or service meets appropriate designatedstandards or has been tested and found suitable for a specifiedpurpose.

1.3.13 Mine Operator. Any owner, lessee, or other personwho operates, controls, or supervises a mine.

1.3.14 Mobile. Any equipment in use without its own motivepower train and normally moved by self-propelled equipment.

1.3.15 Noncombustible. Not capable ofsupporting combustion.

1.3.16 Normal Operation. The regular performance of thosefunctions for which a machine or accessory is designed.

1.3.17 Portable Extinguisher. Extinguishers of the hand-heldor wheeled type that are capable of being carried or movedabout; or transportable systems consisting of a hose reel orrack, hose, and discharge nozzle assembly connected to a sup­ply ofsuppressant.

1.3.18 Self-Propelled Equipment. Any unit that contains amotive power train as an integral part of the unit and is notrail mounted.

1.3.19 Shall. Indicates a mandatory requirement.

1.3.%0 Should. Indicates a recommendation or that which isadvised but not required.

Chapter 2 Fne Protection

%.1 Fire Protection. Fire protection for the purposes of thisstandard shall be defined in the broad sense to include fireprevention, fire detection, and fire suppression. The followingsections shall address these three aspects of fire protectionwithin the context of a fire risk assessment.

%.:Z. Fire Risk Assessment.

%.%.1 A fire risk assessment shall be performed on all self-pro­pelled and mobile surface mining equipment.

%.2.1.1 This assessment shall include evaluation of the poten­tial for the start and spread offire, generation of smoke, gases,or toxic fumes, and explosion that can endanger the lives andsafety ofpersonnel or cause damage to property.

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:11 2010

%.2.1.2 A separate fire risk assessment for each piece ofminingequipment shall be conducted when variations in design, use,condition, and environment could change the fire potential.

2.2.2· The assessment shall include an evaluation of the fol­lowing:

(1) Methods for minimizing or eliminating existing hazard-ous conditions

(2) Use of detection and early fire warning devices(3) Normal and emergency means ofegress from a workplace(4) Presence of barriers or enclosures to prevent or con tain

the spread of fire(5) Availability of fire-fighting personnel and existing fire­

suppression equipment(6) Any other devices or procedures necessary to protect life

and property(7) Use of fire-suppression systems and equipment

2.3* Risk Reduction. Risk reduction practices shall followthe principles of minimizing ignition sources and reducingexposure of combustible materials to ignition sources.

2.3.1 Housekeeping.

%.3.1.1 Spills, leaks, excess lubricants, and combustible mate­rials such as oil-soaked wastes, rubbish, and accumulations ofenvironmental. debris shall not be allowed to accumulate inquantities that could create a fire hazard.

2.3.1.% Approved metal. receptacles shall be provided whereoil-soaked wastes or rubbish are not immediately removed to asafe place for disposal.

%.5.1.3 The storage and handling of flammable or combusti­ble liquidson or within equipment shall be in accordance withSection 4.5 ofNFPA 30, Flammableand Combustible Liquids Code.

%.1l.1.4 Access to fire protection equipment on mining equip­ment shall be kept clear of obstructions.

2.3.2 Welding and Cutting.

%.3.2.1 Gas and electric welding or cutting procedures shallbe in accordance with NFPA 5IB, Standard for Fire PreventionDuring Welding; Cutting; and OtherHot W07k.

2.3.2.% Cutters, welders, and their supervisors shall be trainedin the operation ofequipment.

2.11.%.3 Cutting and welding equipment shall be maintainedin operating condition with aU necessary safeguards in placeand functioning.

%.5.2.4 Compressed gases used for cutting and welding on orwithin the equipment shall be stored in accordance withChapter 2 ofNFPA 51, Standard/or theDtsign and Installation ojOxygm-Fuel Gas SystemsforWelding, Cutting, and Allied Processes.

2.3.%.5 Fully charged and operable fire extinguishers, specifi­cally designed for the class offire to be expected, shall be avail­able at the work area. Where extinguishant hoselines areavailable, they shall be connected and ready for service.

2.!l.2.6 Combustibles posing a fire hazard shall be relocatedor protected with a fire-retardant cover or fire-retardant bar­rier. Openings or cracks in walls, partitions, floor decks, orducts shall be covered tightly to prevent the passage ofsparksto adjacent areas.

%.3.%.7 Where welding on a metal wall, partition, ceiling, or roof,precautions shall be taken to prevent ignition ofcombustibleson

2001 Ediion

Page 8: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 • 64744116 0595583 709 •

121-6 FIRE PROTECTION FOR SELF-PROPELLED AND MOBILE SURFACE MIl'\ING EQUIPMENT

the other side due to conduction or radiation. Such combusti­bles shall be relocated, or a fire watch shall be provided on theopposite side from the work.

2.3.2.8 'A-'here a fire watch is required, it shall be maintained fora minimum of 30 minutes after completion ofcutting or weldingoperations to detect and extinguish smoldering combustibles.

2.3.2.9 The fire watch shall have fire extinguishing equip­ment readily available and be trained in its use.

2.3.2.10 Fire watchers shall be familiar with the facilities andthe procedures for sounding an alarm in the event ofa fire.

2.3.2.11 Welding or cutting on equipment or within enclosedareas of equipment shall not be performed in the presence ofatmospheres containing flammable mixtures of gases, vapors,or liquids with air, or combustible mixtures of dust in suspen­sion with air.

2.3.2.12'" Welding or cutting shall not be performed on orwithin containers or tanks located on equipment, that havecontained combustible or flammable materials, until suchcontainers or tanks have been thoroughly purged andcleaned or inerted.

2.3.2.13 Welding or cutting on equipment shall not be per­formed within 50 ft (15.7 m), measured horizontally, ofexplo­sives, blasting agents, or mine fuel storage areas.

2.3.3 Inspection and Maintenance. Hydraulic, coolant, lubri­cation and fuel lines, electrical wiring, and fire preventiondevices shall be inspected and maintained in accordance withmanufacturer's recommendations.

2.3.4 Training. Personnel shall be instructed in the emer­gency procedures to be followed during a fire.

2.4 Fire Detection and Suppression Equipment.

2.4.1 Portable Fire Extinguishers.

2.4.1.1 All self-propelled surface mining equipment, includ­ing but not limited to bulldozers, front-end loaders, haulagetrucks, cranes, graders, scrapers, draglines, drills, shovels, andmobile diesel and electrical equipment shall be equippedwith at least one listed portable multipurpose (ABC) drychemical extinguisher.

2.4.1.2 Fire exnnguishant applied by hand-portable extin­guishers to hazards involving energized electrical equipmentshall be nonconductive.

2.4.1.3 Portable extinguishers shall be maintained in acharged and operable condition and shall be kept in their des­ignated places at all times.

2.4.1.4 Extinguishers shall be located conspicuously and shallbe accessible.

Exception: In areas where obstruction to visual observation cannotbe completelyavoided, visible markings shall beprovided to indicatethe location.

2.4.1.5 Extinguishers installed under conditions where theycan be subject to physical damage shall be guarded to protectagainst damage.

2.4.1.6* A fire risk assessment shall determine the size, num­ber, placement, rating, and nominal capacity of extinguishersrequired, commensurate with equipment size, configurationand hazards posed, and whether mobile equipment requiresportable extinguishers.

2001 Edition

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:11 2010

2.4.1.7 Portable extinguishers installed on small units of self­propelled and mobile mining equipment including but notlimited to miniature loaders, individual personnel transports,and small mobile generators shall have a minimum rating of2A-I0B, C and a minimum nominal capacity of SIb (2.27 kg)of extinguishing agent.

2.4.1.8 The installation ofan automatic or manually operatedfire suppression system shall not eliminate the portable fireextinguisher requirement.

2.4.1.9 Portable fire extinguishers shall be inspected, main­tained, and recharged as specified in NFPA 10, Standard furPortable Fire Extinguishers, Chapter 4, "Inspection, Mainte­nance, and Recharging," and the following:

(1) Portable fire extinguishers shall be inspected visually atleast monthly.

(2) The visual inspection shall ensure the following:

a. The extinguisher is in its designated place.b. The tamper seals are in tact.c. The extinguisher gauge is in the operable range (if

extinguisher is stored-pressure type).d. There is no obvious physical damage or condition that

will prevent proper operation.

(3) Extinguishers found to be defective or deficient by visualinspection shall be replaced.

(4) Extinguishers shall be subjected to a maintenance exam­ination at least once every year.

(5) Maintenance procedures shall include a thorough exam­ination of the extinguishers, including mechanical parts,extinguishing agent, and expellant.

(6) Any troubles or impairments shall be corrected by com­petent personnel.

(7) All extinguishers shall be recharged after use in accor­dance with the manufacturer's recommendations.

(8) Each extinguisher shall have a durable tag or labelsecurely attached on which the date and initials of theperson performing the maintenance services shall berecorded. The same record tag or label can indicate ifrecharging was also performed.

2.4.1.10 Portable extinguishers shall be tested hydrostaticallyat intervals not exceeding those specified in NFPA 10, Standardfor Portable Frye Extinguishers, Chapter 5, "Hydrostatic Testing."

2.4.2 Fire Detection.

2.4.2.1 Fire detectors shall be permitted to be used to initiateaudible or visual warning, automatic actuation of a fire sup­pression system, or equipment shutdown.

2.4.2.2* Fire detectors shall be tested and listed for theapplication.

2.4.2.3 Compartment sizes and contours, airflow patterns,obstructions, and other characteristics of the protected areashall determine the placement, type, sensitivity, durabilityand, where applicable, the number ofdetectors,

2.4.2.4 All fire detection systems and applicable equipmentshall be tested after installation in accordance with NFPA 72,National Fire Altmn Code", and fire suppression systems stan­dards. It shall not be necessary for testing to require the dis­charge of any associated fire suppression system.

2.4.2.5 At least every 12 months, all fire detection systemsincluding alarms, shutdowns, and other associated equipmentshall be thoroughly examined and checked for proper opera-

Page 9: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595584 645 ..

APPENDIX A 121-7

tion by competent personnel in accordance with the manufac­turer's recommendations. Any equipment found deficientshall be repaired or replaced and the system retested forproper operation.

%.4.%.6 Between the regular maintenance examinations ortests, the detection system shall be inspected visuallyby compe­tent personnel, in accordance with an approved schedulenecessitated by conditions as determined by the mine operator.

2.4.3 Fixed. Suppression Systems.

%.4.3.1· A fire risk assessment shall determine whether self­propelled and mobile equipment shall require a fixed fire sup­pression system.

2.4.3.2 Mining equipment requiring a fire suppression sys­tem shall be protected by a system ofsufficient size to suppresspotential fires in the protected areas and shall comply withthe following.

(a) The fire suppression system shall be approved for thepurpose. Where installed, the equipment shall be located orguarded so as to be protected against physical damage.

(b) Fire suppression systems shall be either automaticallyor manually actuated. Automatically actuated systems shallalso have a manual actuator capable of being activated fromthe operator's compartment or other location.

(c) Depending upon the size of the equipment, additionalground-level manual actuators could be needed to providequick access for manual activation of the system.

(d) Agent distribution hose or pipe shall be secured andprotected against damage, including abrasion and corrosion.

(e) Discharge nozzles shall be protected against entranceof environmental debris, including moisture, dust, dirt, orinsects, by blow-off caps or other similar devices or materials.The nozzle cover shall open or blow off upon discharge ofthe system.

Exception: Paragraphs(b), (c), and (e)shall net apply tosuppressionsystems wing aut<nnatic sprinklers.

(f) The automatic fire-suppression system shall be installedso that system actuation causes shutdown of the protectedequipment.

%.4.3.3 A standby source ofpowershall be provided where electri­cal poweris the only means offire suppression systemactuation.

%.4.5.4 All fire suppression equipment and systems shall betested after installation in accordance with the manufacturer'sor designer's recommendations. Testing shall not require thedischarge of suppressant unless there is no other satisfactorymanner in which the reliability and integrity of the system canbe verified.

%.4.3.5 An installation-and-maintenance or owner's manualthat describes system operation and maintenance require­ments shall be provided for all fire suppression equipment,

2.4.3.6 In accordance with manufacturer's or designer's recom­mended inspection and maintenance procedures and sched­ules, but not to exceed every 12 months, all fire suppressionsystems including alarms, shutdowns, and other associatedequipment shall be thoroughly examined and checked forproper operation by competent personnel Any equipmentfound deficient shall be repaired or replaced and the systemretested for properoperation. Between the regular maintenanceexaminations or tests, the system shall be inspected visually bycompetent personnel, in accordance with the manufacturer's or

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:11 2010

designer's recommended schedule. Testing shall be in accor­dance with the appropriate NFPAstandard.

2.4.3.7 Fire suppression systems shall be maintained in oper­ating condition at all times. Use, impairment, and restorationof the system shall be reported promptly to the mine operator.

2.4.3.8 All persons who can be expected to inspect, test, main­tain, or operate a fire suppression system shall be trained toperform their intended tasks.

2.4.5.9 Where inadvertent discharge of the fire suppressionsystem during servicing could result in injury to personnel,provisions shall be made to safeguard against accidental actu­ation of the system.

%.4.4 Training. All self-propelled and mobile equipmentoperators, supervisors, and maintenance personnel shall betrained in the proper use of fire suppression equipment.

Chapter 3 Referenced Publications

3.1 The following documents or portions thereof are refer­enced within this standard as mandatory requirements andshall be considered part of the requirements of this standard.The edition indicated for each referenced mandatory docu­mentis the current edition as of the date of the NFPAissuanceof this standard. Some of these mandatory documents mightalso be referenced in this standard for specific informationalpurposes and, therefore, are also listed in Appendix D.

5.1.1 NFPAPublicaaioll5. National Fire Protection Association,1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101.

NFPA 10, Standardfrr PortobleFi-reExtinguisheTs, 1998 edition.NFPA30,Flammable and Combwtihle Liquids Code, 2000edition.NFPA 51, Standard for theDesign and Instal10litm ofOrygmF'tIl!l

emSystnnsfor ~1ding; Cutting; and AlliedProcesses, 1997 edition.NFPA SIB, Stondardfor FlTe Prroention During Welding; Cut­

ting, and OtherHot Woril, 1999 edition.NFPA 72, National FireAlarm CodP, 1999 edition.

3.1.% ASTM Publication. American Society for Testing andMaterials, 100 Barr Harbor Drive, West Conshohocken, PA19428-2959.

ASfM D 323, Stondard Metluxl of Test for vapor Pmsure ofPetroleum Products (Reid Method), 1999.

Appendix A Explanatory Material

Appendix A is no: a partof the requireme1l.1.s of this NFPA d0cu.­men: but is includedfor inf0171UJ.tionalPU1fJoses O1Ily. This appendixcontains e~lanatory matenal; numbered tocomspond.with the appli­cabletext paragraphs.A.l.I FIreS adversely affect all types of self-propelled andmobile surface mining equipment including, butnot limited to,trucks, front-end loaders, crawlers,drills, shovels, and draglines,Most fires occur on or near engine exhaust systems, high speeddrive lines, malfunctioning high pressure-high temperaturehydraulic systems,or faulty electrical components.

Total elimination of fire hazards is impossible since sources ofignition and fuel for fires are inherent in the basic equipmentdesign. The fire problem is further complicated by the collectionof environmental debris. Therefore, efforts to reduce fire lossesmust be aimed at fire prevention and fire suppression.

2001 Edition

Page 10: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595585 581 ..

121-8 FIRE PROTECTION FOR SELF-PROPF.LLED AND MOBILE SURFACE MINING EQUIPMENT

To improve fire protection and prevention on surface min­ing equipment, some manufacturers ofmining equipment haveplaced emphasis on the reduction of the fire potential of spe­cific items in the original design of their equipmenL Such itemsinclude turbochargers, exhaust manifolds and exhaust pipeshielding and insulation, location of combustible and flamma­ble liquid reservoirs, and hydraulic and fuel line routing.

Most surface mining equipment is required to have at leastone hand-portable extinguisher mounted in a readily accessi­ble location. Extinguishers are most effective where used bytrained operators. However, considering the sue and configu­ration of machines found at a mine, fires can be difficult orimpossible to fight with a hand-held extinguisher. For this rea­son, fire suppression systems have been developed to aid insuppressing those fires that are hard to access and thereby to

reduce "off-road" equipment fire losses.

The key to operator protection is early detection of fires toprovide a warning to the operator, fuel shut-off to minimizefuel for the fire, and fire suppression during its earliest stages.Specialized systems to perform these functions can be requiredto protect the operator and the machines. To be totallyeffec­tive, however, system operation must be fully understood byowners and operators, and provisions must be made for peri­odic inspection and maintenance.

Fire suppression systems, including hand-portable extin­guishers, offer the mining industry a cost-effective tool bywhich personnel and investments in mining equipment canbe protected.

A1.3.1 Approved. The National Fire Protection Associationdoes not approve, inspect, or certify any installations, proce­dures, equipment, or materials; nor does it approve or evalu­ate testing laboratories. In determining the acceptability ofinstallations, procedures, equipment, or materials, the author­ity having jurisdiction may base acceptance on compliancewith NFPA or other appropriate standards. In the absence ofsuch standards, said authority may require evidence of properinstallation, procedure, or use. The authority having jurisdic­tion may also refer to the listings or labeling practices of anorganization that is concerned with product evaluations and isthus in a position to determine compliance with appropriatestandards for the curren t production of listed items.

A.1.3.2 Authority HavingJurisdiction. The phrase "authorityhaving jurisdiction" is used in NFPA documents in a broad man­ner, since jurisdictions and approval agencies vary, as do theirresponsibilities. Where public safety is primary, the authority hav­ingjurisdiction may be a federal, state, local, or other regionaldepartmentor individual such as a fire chief; fire marshal; chiefofa fire prevention bureau, labor department, or health depart­ment; building official; electrical inspector; or others having stat­utory authority. For insurance purposes, an insurance inspectiondepartment, rating bureau, or other insurance company repre­sentative may be the authority having jurisdiction. In many cir­cumstances, me property owner or his or her designated agentassumes the role of me authority having jurisdiction; at govern­ment installations, me commanding officer or departmental offi­cial may be me authority havingjurisdiction.

A.I.3.12 Listed. The means for identifying listed equipmentmay vary for each organization concerned with product evalu­ation; some organizations do not recognize equipment aslisted unless it is also labeled. The authority havingjurisdiction

2001 Ed~ion

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:11 2010

should utilize the system employed by the listing organizationto identify a listed product,

A.2.2 See Appendix B.

A2.2.2 For additional information, see Appendix B.

A2.3 See Appendix B.

A2.3.2.12 For additional information, see NFPA 326, Stan­dard for the Safeguarding of Tanks and Containers for Entry, Clean­ing, or Repair.

A2.4.1.6 For additional information, see Appendix B.

A.2.4.2.2 See Appendix B.

A.2.4.3. 1 See Appendix B for suggested procedure.

Appendix B FIre Risk Assessment

This appendix is not a part ofthe requirements of this NFPA Me­ument but is includedfor informational purposes only.

B.I Fire Risk Assessment. A fire risk assessment consists ofthe following four phases:

(1) Identify me potential for fire and explosion.(2) Assess me consequences of fire and explosion.(3) Determine me need for fire protection.(4) Select appropriate option(s).

The following fire risk assessment outline is a suggestedprocedure to identify me elements in the items defined above.Figure B.l provides a diagram of me process.

Additional guidance in performing fire risk assessments isprovided in several of the reference publications listed inAppendixC.

B.1.1 Identify the Potential for Fire and Explosion.

(a) Ignition Sources.

(1) High Temperature.High temperatures are usually found inme vicinity of a vehicle engine, exhaust system, pumps,turbochargers, batteries, wiring, switches, electricalmotors, generators, and friction sources such as bearings,brakes, and gears.

(2) Electrical. Electrical ignition sources include switch gear,motor control centers, circuit breakers, motors and gen­erators, transformers, battery boxes, substations, cablereels, trays, and splices and collector rings.

(3) Welding and Cutting.

(4) Other. Smoking materials, chemical reactions, and spon­taneous ignition sources are examples of other sources.

(b) Fuel Sources.

(1) Class A. These materials include combustible debris,wood, rags, electrical insulation, coal dust, upholstery,hoses, tires, and seats.

(2) Class B. This group includes flammable and combustibleliquid materials such as gasoline, diesel fuel, liquefiedpetroleum gas (propane), hydraulic fluids, some coolantcombinations, grease, and oil.

(3) Class D. Some new machines have magnesium transmis­sion components mat cannot be extinguished with con­ventional fire suppression agents.

Page 11: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 II 6474446 0595586 418 II

APPENDIXB 1%1-9

FIG URE B.I F1l'erisk assessment chart.

Fire RIlle:Asaeument

ISlart

Co Many similarities of equipment design and operationexist among the manufacturers. However, within each ofthe equipment categories there are variations in config­urations that could directly influence me fire potential.

(2) Fm IncidentExptrit.nce. Previous fire experience on similarmachines should be considered in the fire risk assess­ment, Past experience can indicate that special hazardsexist, such as hydraulic hose that frequently comes looseat a specific connection on the equipment, equipmentthat has an adverse fire history, or other component fail­ures that increase fire potential.

(3) Qualityof Maintenance.

a. Type and Quality of Replaament Parts. Replacementparts should be at least equal in performance to orig­inal parts. Examples are hoses, bearings, fittings, andelectrical equipment,

b. Frequency. Maintenance should be performed in accor­dance with recommendations and schedules suppliedby the equipment manufacturer.

(4) Househeefring. The presence ofaccumulations ofcombusti­ble materials such as oil-soaked waste, fuel spillage, excesslubricant, and coal dust represent potential fire hazards.

B.l.% Assess the Consequences of Fire and Explosion.

(a) Personnel Exposure.

(1) Number and Location. Determine the number of personsinvolved and their location during routine and mainte­nance operations.

(2) RisltExpostm. Determine the exposure to potential fire andexplosion risks for each person, and whether the fire andsmoke could impair safe egress from their work locations.

(b) Economic Risks.

(I) Properly Damage. Consider the cost of repairs, replace­ment, cleanup, and damage to the work site.

(2) Busimss Int.erruptinn. Items to consider are productionloss, personnel overtime, interruption of customer deliv­eries, and replacement equipment rental.

B.1.3 Determine the Need for Fare Protection.

(a) Mandatory Requirements. Certain fire prevention andfire suppression requirements are mandated by company pol­icy, insurance companies, and government agencies.

(b) Identified Needs. Additional fire precautions beyondthose that are mandated might prove to be necessary, after thefire risk assessment,

(c) Evaluate. H the fire risk assessment has disclosed unac­ceptable personnel risks, economic risks, or both, appropriatefire protection options shall be determined. H the risks arefound acceptable, no further action is required.

B.l.4 Select Appropriate Option(s).

(a) Risk Reduction.

(1) Machine Design. Evaluate equipment to determinewhether the risk from the start or the spread of a fire, orthe risk to personnel from a fire can be reduced. Exam­pies concerning how to reduce the start or spread ofa fireinclude physical barriers between fuel sources and igni­tion sources, thermal shields over hot surfaces, hose andwiring harness routing, support, and protection, andpower shutoffs. Examples for reducing the threat of fireto personnel include emergency egress provisions andrelocating or shielding potential fire hazards.

Firaprotection:1. Portable fire

extinguishers2. Firedetection

systems3. FIXed fire

suppressionsystems

Life safety

Fira risk reduction:1. MachinedesilJ1

modification2. Operating

procedures

Slop

IV Selectappropriateoption(s)

(c) Probability of the Coexistence of Fuel and IgnitionSources.

(l) Proximity ojFml toIgnition &mrces.

a. MachineDesign. An assessment should be made ofexist­ing areas where lubrication, hydraulic oil, or fuel linesare in proximity to an engine surface or other heat­emitting equipment component, Other areas includeequipment articulation points, parking brakes, enginepan area, and battery compartments. Areas not to beoverlooked on larger equipment include roller path!collector ring areas, electrical switch gear, and trans­former compartments. Existing thermal shields, hoserouting, electrical harnesses, and their support caninfluence the potential for fire.

b. In identifying risk areas note that a combustible liquidcan spray or drip onto a hot surface remote from therupture or leak point, Likewise, spatter from a batteryor an electrical switch short can carry heat to anotherarea of the machine.

Identify thepotentialfor fire andexplosion

Economic

III Determinetheneed forfireprotection

II Assesslheconsequencesof fire andexplosion

2001 EIIIIon

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:12 2010

Page 12: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595587 354 II

121-10 FIRE PROTECTION FOR SELF-PROPELLED AND MOBILE SURFACE MINING EQUIPMENT

(2) operatingPrograms and Procedures. Mine operators, throughimplementation of policies and procedures, can reducethe threat of fire and explosion. Examples include effec­tive equipment maintenance programs, adequate house­keeping procedures, proper employee training, anddevelopment of emergency plans and strategies that dealwith fire and explosion hazards. Such emergency planscan include use of company fire brigades and other avail­able equipment such as fire trucks and water wagons, andthe response of local fire departments.

(3) Evaluate. Determine whether risk reduction reduces risksto acceptable levels. If risks are within acceptable levelsno further action is required. If unacceptable risks stillexist, then action is required either to further reduce haz­ards or to install fire detection/suppression equipmentor a combination of both.

(b) Fire Detection and Suppression Equipment,

NOTE: A more detailed discussion of fire suppression anddetection equipment can be found in the references in Appen­dix C and NFPA 10. Standard for PortableFireExtinguishl!rS.

(1) Identify Available Alternative,s.

a. Portable Protection. Options include hand-portableextinguishers, hose reels and lines, wheeled extin­guishers, and skid-mounted extinguishers.

To handle difficult fires, larger capacity extinguishersthat provide more agent, greater range, and longerdischarge time are recommended for agent selection[seeB.1.5(a)].

b. Detection. Fire detection devices can be used to provideearly warning of fires, actuate a fire suppression sys­tem, shutdown equipment, and operate other systemssuch as door closers and exhaust fans. (For a discussionofdetectorand control options, selection, and placement, seeB.l.5(c) and B.l.5(d).]

c. Fixed Fire Suppression Systems. Fixed system protectioncan be accomplished by local application, total flood­ing, or a combination of both, or automatic sprin­klers. (For agent selection, see B.l.5(a). For fixed presuppression system options, see B.l.5(b).]

(2) Compare Capability with Need. Mandatory requirementsand identified needs should be matched with the mostcost effective approach to fire detection, fire suppression,or both.

(3) Select Equipment. The selection of all equipment used fordetection and suppression of fires in mining equipmentshould be based upon consideration of the environmentwhere the equipment will function and should be tested.Testing should include provisions for determining theadequacy and durability of the equipment, and the man­ufacturer should demonstrate that such tests have beenconducted.

(4) Evalunte. Determine whether risk reduction results in com­pliance with mandatory requirements, or reduces risks toacceptable levels,or both. If risks are within acceptable lev­els, no further action is required. Ifunacceptable risks stillexist, then action is required either to reduce hazards fur­ther or to install fire detection/suppression equipment ora combination of both.

B.1.5 Fire Protection Agents and Equipment.

(a) Fire Suppression Agents. The following extinguishantsare commonly used in the mining industry:

2001 Edition

- --- -

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:12 2010

(1) Class A. Dry chemicals (ABC) with ammonium phos­phate as the basic ingredient.

a. Foams: protein, fluoroprotein, aqueous film forming,medium and high expansion

b. Waterc. Clean agentsd. Halons

(2) Class B. Dry chemicals (BC) with sodium bicarbonate,ammonium phosphate, potassium bicarbonate, urea­based potassium bicarbonate, or potassium chloride asthe basic composition.

a. Foams: protein, fluoroprotein, aqueous film formingfoam, medium and high expansion

b. Carbon dioxidec. Halonsd. Watere. Clean agents

(3) Class C Dry chemicals (ABC or BC) with sodium bicar­bonate, ammonium phosphate, potassium bicarbonate,urea-based potassium bicarbonate, or potassium chlorideas the basic composition.

a. Carbon dioxideb. Halonsc. Waterd. Clean agents

(4) ClassD, Dry powder agen ts composed ofsodium chlorideor graphite with other particulate material added. Inertmaterials such as dry sand, foundry flux, and so on.

(b) Method of Application.

(1) Fixed Systems. The design and layout of fixed fire suppres­sion systems should be based upon the method of appli­cation of the fire suppressant to the area to be protected.Methods of delivery include the following:

a. Local application consisting of a supply of suppressantpermanently connected to a distribution system arrangedto discharge onto a defined area or space

b. Total flooding consisting of a supply of suppressant per­manently connected to a distribution system arranged todischarge into an enclosed space

c. A combination of a. and b. aboved. Automatic sprinklers consisting ofa supply of suppres­

sant (normally water) permanently connected to a dis­tribution system to discharge the suppressant

(c) Detector Options.

(I) Automatic fire detection devices are covered by NFPA 72,National Fire Alarm Code. One fire detection device that iscommonly used in self-propelled and mobile miningequipment but is not covered in !\"FPA 72 is fusible plastictube. It comprises a sensing element consisting of a plas­tic tube pressurized with inert gas. Heat from the firecauses the tube to burst, releasing the gas pressure andactivating a mechanical pneumatic actuator.

(2) Fire Detector Placement. Consideration should be givento the physical configuration of the area to be protectedwhen selecting and locating detectors. A detector'sresponse time is dependent upon its type and proximity toa fire. For spacing, see NFPA 72, NationalFire Alarm Code.

Other factors to be considered in fire detector place­ment are ambient temperature, climatic conditions,shock and vibration, air contamination, ventilation flows,and maintenance requirements.

Page 13: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 II 6474446 0595588 290 II

APPENDIXC 121-11

(d) Control Options.

(1) Depending on mining equipment configuration, use,ground speed capability, degree of hazard enclosure,operating personnel locations, and other factors, consid­eration may be required ofsystem control options such asthe following:

a. Discharge time delayb. Discharge abort switchc. Audible and visual alarmsd. Pre-discharge alarme. Detection circuit supervision

B.2 Electrical Ignition Hazards. Self-propelled and mobilesurface mining equipment powered by electrical energy arenormally supplied through portable electrical power cablescarrying high-voltage, three-phase, ac power. Existing regula.tions require that the electrical system be designed to protectpersonnel by limiting the voltage rise of the machine frame, inthe event ofa ground fault, to a maximum of100 volts. Protec­tion on such electrical systems includes the following:

(1) Normal overcurrent protection(2) Ground-fault current limitation (normally to about

15 amperes)(3) Ground-fault overcurrent tripping (usually at about

7 amperes to 10 amperes)(4) Monitoring of continuity of the ground conductor in

the trailing cable and instantaneous tripping ifcontinu­ity is lost

Electrical systems having these protective features are sin­gularly free of fires, as fault current is low and faults arecleared rapidly.

When equipment contains one or more transformersdesigned and installed to reduce the high voltage suppliedthrough the portable cable to a lower utilization voltage, norequirements for ground-fault current limitation or trippingon ground-fault interrupters are necessary. All equipment onthe machine is effectively frame grounded, and there is no riskto personnel due to frame voltage rise.

Alternatively, a ground detection system can be used on anungrounded utilization voltage system, provided the firstground, which would cause an alarm, is found and repairedpromptly. Use ora time delay to allow an orderly and safe shut­down of a machine followed by automatic removal of powerfrom the grounded circuit is recommended.

Appendix C SuggestedReferences

This appendix is not a part oftherequirements of thisNFPA doc­ument but is includedfor informational jn.nposes only.

C.l NFPA Publications. National Fire Protection Association,1 Batterymarch Park, P.O. Box 9101, Quincy, MA02269-9101.

NFPA 10, Sta1ll1ardfor Porloble Fin Extinguishers, 1998 edition.NFPA 11, Standard for Luw-ExpansionFoam, 1998 edition.NFPA l1A, Standard for Medium- and High-&pansion Foam

Systems, 1999 edition.NFPA 12, Standard on Carbon DioxideExtinguishing Systems,

2000 edition.NFPA 12A, St.andard on Halon 1301 Fin Extinguishing Sys­

tems,1997 edition.NFPA 13, Standard for the Installation of sprinkler Systems,

1999 edition.

Copyright bi the-National Fire Protection AssociationTue Feb 09 14:54:12 2010

NFPA 14, Standardfor the Installation ofStandpipe, PrivateHydrant, and Hose S:J5Iems, 2000 edition.

NFPA 15, Standardfor Waterspray FWd Systems fur Firt Proteo­tum, 1996 edition.

NFPA 17, Standard for Dry Chemical Extinguishing Systems,1998 edition.

NFPA 20, Standardfor theInstallation ofStationary Pumps forFm Protection, 1999edition.

NFPA 22, Standardfor Water Tanllsfor PrivateFm Protection,1998 edition.

NFPA 51B, Standardfor Fm P-rromtion During Wading, Cul-ting, and OtherHot W01II, 1999 edition.

NFPA69, Standmri onExplosUm PmJentibn Systems, 1997edition.NFPA 70, National Elutrical ce», 1999 edition.NFPA 72, NationalFrrtAltmn CodP, 1999 edition.NFPA230,StanJarrlfO'TtheFmProtet:tUmofS~I999edition.

NFPA326, Standard fM' theSaftguardingofTanlls andContain-t:TS for Entry, Clmning, orRepair, 1999 edition.

NFPA 385, Standardfor Tank Vehicles for Flammable and~bustible Liquids, 2000 edition.

NFPA 1962, StandardfM' the Care, Use, and Sensc« TestingofFm HoseIncluding Couplings and Nozzles, 1998 edition.

NFPA 1963, StandardforFm Hose Conmctions,1998 edition.NFPA 2001, Standard on Clean Agmt Fin Extinguishing Sys­

tems, 2000edition.Fm Protectibn Guitk to Hazardous Materials, 11th Edition,

NFPA, 1997.Fin Protection Handbook, 17th Edition, NFPA, 1991.

c.% Other Publications.

C.%.1 ANSI PubHcations. American National Standards Insti­tute Inc., 11West42nd Street, 13th floor, NewYork, NY 10036.

ANSI A92.2, Vtlhicle-Mountecl EJ.eualing and Rotating AerialDeoices, 1979.

ANSIA92.3,Elevating W01II P1LItforms, ManuallyPropdJecl, 1980.ANSI B30.5,Mobiland Locomotio« Cranes, 1994.ANSI 505, PownwiIndustrial Trucks (NFPA505-1981), 1992.ANSI 583, Battery Pawered Trucks (UL 583-1977), 1991.

C.2.2 ASTM Publication. American Society of Testing andMaterials, 100 Barr Harbor Drive, West Conshohocken, PA19428r2959.

ASfM E 136, TestMethodfor BehaviorofMaterialsin a VnticalTubt Furnace at 750"C, 1994.

C.2.S IEEE PubHcation. Institute of Electrical and Electron­ics Engineers, Inc., 445 Hoes Lane, P.O. Box 1331, Piscataway,NJ 0885~1331.

IEEE Standard 446, &commendecl Practice for Emergmcy andStandby Pouer Systems for Ind'UStriaJ. and Commercial Appliwticms,1987.

C.%.4 SAE Publications. Society of Automotive Engineers,400 Commonwealth Drive,Warrendale, PA 15096.

SAE J53, Minimum Performana Criteria for EmergtTI"J SteeringofWheeled Forthmuuing Construction Machines, Rec011fl'M1lded Prac­tice, 1984.

SAEJI85, AcclSS S:J5tems for Off-R0a4 Machines, RecommendedPractice, 1988.

SAE]833A USA, Maleand FemoJ.e PhysicalDimensionsfor Con­struction and IndustriJJlEquipmmt, 1980.

SAE J925, Minimum AcclSS Dimensitms for Construction andIndustrial Equiprntnt, 1993.

2001 Edllon

Page 14: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595589 127 ..

121-12 FIRE PROTECTION FOR SELF.PROPELLEDAND MOBlLF.SlJRFAC..E MINING EQUIPMENT

G.3 Additional References.

C.3.1 SAE Publications. The following reports are availablefrom the Society of Automotive Engineers, 400 Common­wealth Drive, Warrendale, PA 15096.

deLime, T. L, "Improved Fire Protection for Off-HighwayEquipment" Society of Automotive Engineers Off-HighwayVehicle Meeting, Milwaukee, Sept. 1979, SAE 790882.

Jewett,]., "Fire Suppression Systems" Society ofAutomotiveEngineers Off-Highway Vehicle Meeting, Milwaukee, Sept.1979, SAE 790779.

Johnson, GA, "Improved Fire Protection Systems for Sur­fuel" Coal Equipment" Society of Automotive Engineers Off­Highway Vehicle Meeting, Sept. 1977, SAE 770744.

Pomroy, W. H., "Improved Automatic Fire Protection Sys­tems for Off-Highway Mine Vehicles" Society of AutomotiveEngineers Off-Highway Vehicle Meeting, Milwaukee, Sept.1979, SAE 790880.

C.3.2 Former U.S. Department of Interior Bureau of MinesPublications. The following former Bureau of Mines reportsand articles are available for Open File (OFR) inspection atthe following locations: National Institute for OccupationalSafety & Health (NIOSH) Facilities: Pittsburgh, PA and Spo­kane, WA; US Geological Survey, Reston, VA; and the NationalMSHA Technical Information Center and Library, Beaver,WV (email: Library@MSTh\.gov). They may also be obtaineddirectly from the National Technical Information Service(NIST), .'}285Port Royal Road, Springfield, VA.

Baker, R M., "An Annotated Bibliography of Metal andNonmetal Mine Fire Reports," 1980. U.S. BuMines OFR 68(1)-(3)-81. NTIS PB 81-223711.

*Kllsten, A. E., "Develop and Test an Automatic Fire ControlSystem for Surface Mining Machinery, Volume I, Systems Devel­opment," 1977. u.s. BuMines OFR 119-78. NTIS PB 293 983.

Lease, W., "Development and Testing of a Fire ProtectionSystem for Coal Augers," 1975. U.S. BuMines OFR25-76. NTISPB 249-865.

Lease, W., "Development, Installation, and Testing Servicesfor an Automatic, Point-Type Thermal Sensor Fire ProtectionSystem on a Mining Dozer," 1976. U.S. BuMines OFR 71-77.NTIS PB 266075/AS.

*Lease, W. D., "Development of an Automatic Fire Protec­tion System forSurfa.ce Vehicles," 1981. U.S. BuMines OFR 73­82. NTIS PB 82-215765.

*McDonald, L.A., "Development and Test of an AutomaticFire Control System for Surface Mining Machinery, Volume II,Reliability Testing," 1981.

*McDonald, L.A., "Improved Fire Protection System forAN-Fa Haulers and Loaders," 1982. U.S. BuMines OFR46-83.

*Stevens, R. B., "Improved Sensors and Fire Control Systemfor Mining Equipment," 1972. U'S, BuMines OFR 25 (1)-(2)-74. NTIS PB 232405 and NTIS PB 232406.

Stevens, R. B., "Automatic Fire Sensing and SuppressionSystem for Mobile Mining Equipment," 1978. U.S. RuMinesOFR 34-79. NTIS PB 294 731.

The following Bureau of Mines reports are available fromthe Section of Publications, Bureau ofMines, 4800 Forbes Ave­nue, Pittsburgh, PA 15213.

2001 Edition

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:12 2010

Johnson, G. A., "Automatic Fire Protection Systems forLarge Haulage Vehicles; Prototype Development and In-MineTesting," 1978. U.S. BuMines IC 8683.

*Pomroy, W. H., "Automatic Fire Protection Systems forSurface Mining Equipment," 1980. U.S. BuMines IC 8832.

Pomroy, W. H., ~A Statistical Analysis of Coal Mine FireIncidents in the United States from 1950 to 1977," 1980. FS.BuMines IC 8830.

*Pomroy, W. H., "Economic Analysis of Surface MiningMobile Equipment Fire Protection Systems," 1982. U.S.BuMines RI 8698.

U.S. BuMines Mining Research Staff, "Metal Mine Fire Pro­tection Research," 1977, BuMinesIC 8752.

U.S. Mines Technology News No. 27, 1976, "Automatic FireProtection for Surface Coal Augers."

U.S. BuMines Technology News No. 50, 1978, "BulldozerFire Protection."

U.S. BuMines Technology News No. 70,1979, "Fire Protec­tion for Blasthole Drill."

U.S. BuMines Technology News No. 74,1979, "Fire Protec­tion for Front-End Loaders."

U.S. BuMines Technology Nf'WS No. 77, 1980, "LoadingShovel Fire Protection."

U.S. BuMines Technology News No. 78,1980, "Fire Protec­tion for Hydraulic Excavators."

U.S. BuMines Technology News No. 79, 1980, "AutomaticFire Protection for Mining Trucks."

U.S. BuMines Technology News No. 106,1981, "DraglineFire Protection."

U.S. BuMines Technology News No. 107, 1981, "An-FoHauler Fire Protection."

C.S.S Other Publications.

Jenson, R., ed., "Fire Protection for the Design Profes­sional," 1975. Cahners Books, A Division of Cahners Publish­ing ('..0., Inc., 89 Franklin Street, Boston, MA 02110.

Accitknt Prevention Manual for Industrial Operations. NationalSafety Council, 425 North Michigan Avenue, Chicago, IL 60611.

NOTE: Publications marked with an asterisk provide infor­mation on fire risk assessment.

Appendix D Referenced Publications

D.l The following documents or portions thereof are refer­enced within this standard for informational purposes onlyand are thus not considered part of the requirements of thisstandard unless also listed in Chapter 3. The edition indicatedhere for each reference is the current edition as of the date ofthe NFPA issuance of this standard.

D.l.l NFPA Publications. National Fire Protection Association,1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101.

NFPA 10, Standardfor PortableFire Extinguishers, 1998 edition,

NFl'1\. 72, National Fire Alarm Code", 1999 edition.

NFPA 326, Standardfar theSafeguardingofTanks and Contain­IfTS fOT Entry, Cleaning, OT Repair, 1999 edition.

Page 15: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595590 949 ..

INDEX

Index

1%1-13

©2001 National Fire Protection Association. All Rights Reserved.

The copyright in this index is separate and distinct from the copyright in the document that it indexes. The licensing provisions set forth for thedocument are not applicable to this index. This index may not be reproduced in whole or in part by any means without the express written per­mission of NFPA.

-A-

Access, to fire protection equipment 2.3.1.4Approved (definition) 1.3.1. A.I.3.1Authority bavingjurlsdiction (definition) 1.3.2. A.l.3.2

.8-

Barriers 2.2.2(4)Blasting agents 2.3.2.13

-c-Combustible (definition) 1.3.3Combustible liquids 2.3.1.3

Definition 1.3.11.1Combustible materials 2.3.2.6 to 2.3.2.7,2.3.2.12, A.2.3.2.12Combustion (def"mition).............••.•..•.....•.•..••• 1.3.4Compretllied gases. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2.4Containers .•....•..•....•............•..•. 2.3.2.12. A.2.3.2.12Cutting and welding seeWelding and cutting

-D-Def"mitions 1.3, A.1.3Dry chemical fire extinguishers 2.4.1.1Dust 2.3.2.11

-&

Egress,emergency 2.2.2(3)Definition ....•...••......•..•........•..•....•••••. 1.3.5

Electrical ignition hazards B.I.l (a) (2). 8.2Emergency egress 2.2.2(3)

Definition .....•.••....••.••••.....•••.•••......••.. 1.3.5Employees

Exposure .•...................................... B.1.2(a)

Training 2.3.4. 2.4.4Enclosures .......•.•.••.....•...•.•....•..•.•...... 2.2.2(4)Equipment operatoJS

Definition ••........................................ 1.3.6

Training 2.4.4

Equivalent protection 1.2.3EJr.plollives , .2.3.2.13EJr.tinguishers, portable fire 2.3.2.5.2.4.1. B.1.4(b)(l)(a)

Definition 1.3.17

Size and placement 2.4.1.6. A.2.4.1.6

-F-

Fire detection 2.2.2(2),2.4.2, A.2.4.2.2, 8.1.4(b}Fire protection Chap, 2. A.2. 8.1Fire retaJdant oovcJS/barrleJS 2.3.2.6Fire rilik

Assessment, 2.2,2.4.3.1, A.2.2, A.2.4.3.1, App. 8Definition 1.3.7

Reduction 2.3, A.2.3, B.1.4(a}Fire suppresllion agents B.1.5(a}Fire suppresllion systems/equipment 2.2.2(5), 2.2.2(7), 2.4.1.8;

seealso Fixed suppression systemsFire watch 2.3.2.7 to 2.3.2.10

Copyr~ht by the'National Fire Protection AssociationTue Feb 09 14:54:12 2010

FIXed supprelillion systems 2.4.3, B.1.4(b) (l)(c), B.1.5(b)(l}Definition 1.3.B

Flammable (definition) 1.3.10Flammable liquids 2.3.1.3, 2.3.2.11

Definition ••............................•.•••••... 1.3.11.2Flammable materials 2.3.2.12, A.2.3.2.12F1aIib point (definition) 1.3.9Fuel sources B.1.1 (b), 8.1.1 (c)Fuel storage areas. 2.3.2.13

-G-

GasesCompressed 2.3.2.4

Flammable 2.3.2.11

-H-Hazards

Electrical ignition B.l.l (a)(2), 8.2

Minimization of. 2.2.2(1)Hose lines '" •....................... 2.3.2.5Housekeeping ••........••...•••....•.•.........••.••.. 2.3.1

·1·

Ignition sources B.l.l (a), B.l.l(c), B.2Inspection 2.3.3

Detection systems 2.4.2.5 to 2.4.2.6

Fire extinguishers. portable 2.4.1.9

Suppression systems 2.4.3.6.2.4.3.8

-L-

Labeled (definition)••.•....•..•..•...........•.....•..•1.3.10Liquids (defioitiol15) 1.3.11Listed (def"mition) 1.3.12, A.1.3.12

-M-Maintenance 2.3.3

Detection systems 2.4.2.5 to 2.4.2.6

Fire extinguishers, portable •......................... 2.4.1.9

Suppression equipment .....•.•••........... 2.4.3.5 to 2.4.3.8

Metal receptacles, waste .......................••....•. 2.3.1.2Mine operator (definition) 1.3.13Mobile (def"mition) 1.3.14

-N-

Noncombustible (definition) 1.3.15Normal operation (dermition) 1.3.16

.p,

Power.litandby ......•...............•................ 2.4.3.3Purpose of standard 1.2

-R-

Referenced pubHcations Chap. 3, App. 0Risk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S....Fire risk

2001 Edition

Page 16: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595591 885 ..

121-14 FIRE PROTECTION FOR SELF-PROPELLED AND MOBILE SURFACE MINING EQUIPMENT

-8-

Scope ofstandard .. '" 1.1, A.1.1Self-propelled equipment (deftnition) . '" 1.3.18Shall (defmition) '" 1.3.19Should (defmition) 1.3.20Sparks 2.3.2.6Storage

Compressed gases 2.3.2.4

Flammable and combustible liquids 2.3.1.3Suppression systems, flre ... SM Fire suppression systems/equipment

-T-

Tanks '" 2.3.2.12. A.2.3.2.12

2001 EditiOn

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:13 2010

TestingDetection systems 2.4.2.4 to 2.4.2.6

Extinguishers, portable fire 2.4.1.10

Suppression equipment 2.4.3.4, 2.4.3.6, 2.4.3.8

Training, employee 2.3.4, 2.4.4

-V-

Vapors, flammable 2.3.2.11

-w-Waste receptacles 2.3.1.2

Welding and cutting 2.3.2, A.2.3.2.12, B.1.l.3. Bd.I (a)(3)

01 02 03 04 05 6 5 4 3 2 1 CoulD

Page 17: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 II 6474446 0595592 711 II

&que.:e ofEDents 1MJdirIg to Puhlicatitmoffill NFPA e.m..ittre Dot:wMnI

CaD goes outfor proposals to amend ezistiDg documentorforn:commendations on new document...

Committee meets to act on proposals, to degelop its ownpro­poaJs, and to prepare its report...

Committee~ on proposalaby letter ballot. H two-tbirda ap­prove. reportgoes forward. Lacking two-tbiIda

approval. report mums to committee...Report - &part onPropotsals (ROP) - is published for public

review and comment...Committee meets to act on each public comment received...Committee votes on comments by letter ballot. H two-thirds

approve. supplementary report goes forward.Lading two-thirds approva1, IUpplementary report retIJJ1II to

committee...Supplcmentaryrcport- lWJN1rI Oft c.o..-nts (ROC) - ispub­

lished for public review...NFPAmembenbip meets (Annual or FaDMeeting) and acts

on C01DIDittee report (ROP or ROC)...Committee votes on any IIIIleDdmc::nts to report applChed at

NFPAADnualor FaDMc:ctiDg...Appeals to &aadarda Council on AIIoc:iatioD action IDUIt be

fi1ecl~ 20 dayI of the NFPAAnnual or FaDMeeting...SIaadards Councildec:idea, baled on. aDmdalc:e, whetheror DOt to iIIue ItaDdani or to take otheraction, including

npbo1dingany appeal&.

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:13 2010

The following cJassi6cations apply to Technical Commit­tee members and reprcaent their principal interest in theactivity ofa committee.

M ~Arepresenwneofamakerormarketerof

a product, assembly.or system, or portion thereof. thatis afrccted by the standard.

U u.r.A~ of an entity that is sul:!ject to theproviaicma of the standard or that 1'Olun1ari1y UICll thestaDdard.

11M 1nsIII1ler~A repraen...me ofan entity that isin the business ofinJtaDingormaintaininga product.as­sembly. or system. affected by the I13Ddard.

L Ltlbtw: A labor~ or employee c:onc:emedwith safety in the workplace.

R/T AppliMl BIIttGrr:I&IT,." 1..tIJJtntDrJ: A~ ofan independent telling laboratory or independent ap­plied researdl organization that promulgat.cs and/or .cnfon:es standards.

E ~ AutADrU,: A~ of an apcy oran mpnization that pmnndptes and/or eaforcesItandaIda.

I ~ A rquaentathe of an insurance company.broker. agent, bureau, or iDIpeaion agency.

c c.o.uu-r:A penon who is.or repsaenu. the uItimatI:pmcbaIerofa product. syataD. oracnice atm:tcdby thestandard,botwhoilnotinc:ludedintheu-da-ffiearion

SE SJ-dDl&J-t:A peIIOIl Dot lepreoenting any of the pre­*»us cJanificatiollS, butwho has special eKpeI'tiIe in theIcope oIthe IIandaid or ponion thereoE

NOTE1: -samdud" CXIIJDCIIeI code, ICaDdard. lei 'M'lIItendedpraake, (II' I'JIde.Non:2:A~iDdudeI_~

NOTE 5: WbiIe daeIe dteejtieeticww will be UIed by the SIaD­dink CoaDciI to lIdIiege a baImce fix' TedmicIl OM"hri .......the StaDdmk CoaDcil maycleuawiDe tbal_ c1MojfjcaricwollDelllben or WIiqae iDlIeftIII Deed rep"""Wion in orderto tiIJIter die belt poIIibIe • <""m;......~ OIl aD)'Jl'I'C!iect. III dIiI CMneait"'. die StaDdanII CouDdl mayDmbIUCh appaintmeD••itcteeu. appI'OIIIiate in 1be pIbIic iDIJeI'.-.1lICh.1be lwiftreflcwt Clf-Udlilies" in the NadoIW EIef>1ricalCode O-nrineeNOTE 4:~ClfIUblidiuiDClf-rpoup are ....eraDr CIODIideIed ID bae the __ cII-ifiaticm • die peJeDt

orpniDri«m

1/00

Page 18: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD·NFPA 121-ENGL 2001 II 6474446 0595593 658 II

FORM FOR PROPOSALS ON NFPA TECHNICAL COMMITTEE DOCUMENTS

Mail to: Secretary, Standards CouncilNational Fire Protection Association, 1 Batterymarcb Park, Quincy, Massachusetts 02269-9101Fax No. 617·778-3500

Note: All proposals must bereceived by 5:00 p.m. ESTIEDST on the published proposal-closing date.

H you need Curther inCormation on the standards-making process, please contact theStandards Administration Department at 617·984-7249.

For teclmicaI assistance, pleasecall NFPAat 617.770-3000

Please indicate in which fonnat you wishto receiveyour ROPIROC: 0 paper 0 electronic 0 download

(Note: In choosing the downloadoptionyou intendto view the ROPIROC from our website; no copy willbe sent to you.)

Date Name TeL No. _

COmpany _

Street Address _

Please Indicate Organization Represented (it 8Oy) _

1. a) NFPA Doc:ument Title NFPA No. & Year _

b) SectionIParagrapb _

2. Proposal Recommends: (Check one) (J new texto revised texto deleted text

FOR OFFICE USE ONLY

Log , _

Date Rec'd _

3. Proposal (include proposed new or revised wording, or identification of wording to be deleted): (Note:Proposedtext shouldbe in legislative format: i.e.,use underscore to denotewording to be inserted <iDsI:tI:lllllDl'.diD&> and strike-through to denotewording tobe deleted (111111111 ....>.

4. Statement ofProblem and Substantiation for Proposal: (Note:State theproblemthat will be resolved by yourrecommenda­tiou; give the specificreason for yourproposal including copiesof tests, researchpapers, fire experience, etc. Ifmore than200words,it may beabstracted for publicalion.)

5. (J This Proposal is original materiaL (Note: Original materialis considered to be thesubmitter's own idea based on orasa resultofbisIberownexperienee,thought, or research and, to thebest of hisIher knowledge, is not copiedfrom another source.)

(J This Proposal is not original material; its source (it known) is as foUows: _

Note I: Type or print legiblyin blackink.Note 2: If supplementary material (photographs,diagrams,reports, etc.) is included, you maybe required to submitsufficient copies for all mem­bers and altematesof the technieal committee.

I hereby grant the NFPA all andfull rights in copyright, in this proposal, and 1 understand that 1 acquire no

rights in any publication ofNFPA in which this proposal in this or another similar or analogous form is used.

Signature (Required)

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:13 2010

PLEASE USE SEPARATE FORM FOR EACH PROPOSAL 1/00

Page 19: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 II 6474446 0595594 594 II

NOTICES

All questions or other communications relating to this document and all requests for information on NFPAprocedures governing its codes and standards development process, including information on the procedures forrequesting Formal Interpretations, for proposing Tentative Interim Amendments, and for proposing revisions toNFPA documents during regular revision cycles, should be sent to NFPA headquarters, addressed to the attentionof the Secretary, Standards Council, National Fire Protection Association, I Batterymarch Park, P.O. Box 9101,Quincy, MA 02269-9101.

Users of this document should be aware that this document may be amended from time to time through theissuance of Tentative Interim Amendments, and that an official NFPA document at any point in time consists ofthe current edition of the document together with any Tentative Interim Amendments then in effect. In order todetermine whether this document is the current edition and whether it has been amended through the issuance ofTentative Interim Amendments, consult appropriate NFPA publications such as the National Fire Codes~

Subscription Service, visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed above.A statement, written or oral, that is not processed in accordance with Section 6 of the Regulations Governing

Committee Projects shall not be considered the official position of NFPA or any of its Committees and shall notbe considered to be, nor be relied upon as, a Formal Interpretation.

The NFPA does not take any position with respect to the validity of any patent rights asserted in connectionwith any items which are mentioned in or are the subject of this document, and the NFPA disclaims liability forthe infringement of any patent resulting from the use of or reliance on this document. Users of this document areexpressly advised that determination of the validity of any such patent rights, and the risk of infringement of suchrights, is entirely their own responsibility.

Users of this document should consult applicable federal, state, and local laws and regulations. NFPA doesnot, by the publication of this document, intend to urge action that is not in compliance with applicable laws, andthis document may not be construed as doing so.

Licensing Policy

This document is copyrighted by the National Fire Protection Association (NFPA). By making this documentavailable for use and adoption by public authorities and others, the NFPA does not waive any rights in copyrightto this document.

1. Adoption by Reference--Public authorities and others are urged to reference this document in laws,ordinances, regulations, administrative orders, or similar instruments. Any deletions, additions, and changesdesired by the adopting authority must be noted separately. Those using this method are requested to notify theNFPA (Attention: Secretary, Standards Council) in writing of such use. The term "adoption by reference" meansthe citing of title and publishing information only.

2. Adoption by Transcription-A. Public authorities with lawmaking Dr rule-making powers only, uponwritten notice to the NFPA (Attention: Secretary, Standards Council), will be granted a royalty-free license toprint and republish this document in whole or in part. with changes and additions, if any, noted separately, inlaws, ordinances, regulations, administrative orders, or similar instruments having the force of law, provided that:(I) due notice of NFPA's copyright is contained in each law and in each copy thereof; and (2) that such printingand republication is limited to numbers sufficient to satisfy the jurisdiction's lawmaking or rule-making process.B. Once this NFPA Code or Standard has been adopted into law. all printings of this document by publicauthorities with lawmaking or rule-making powers or any other persons desiring to reproduce this document orits contents as adopted by the jurisdiction in whole or in part, in any form, upon written request to NFPA(Attention: Secretary, Standards Council), will be granted a nonexclusive license to prim, republish, and vendthis document in whole or in part, with changes and additions, if any, noted separately, provided that due noticeof NFPA's copyright is contained in each copy. Such license shall be granted only upon agreement to pay NFPA aroyalty, This royalty is required to provide funds for the research and development necessary to continue the workofNFPA and its volunteers in continually updating and revising NFPA standards. Under certain circumstances,public authorities with lawmaking or rule-making powers may apply for and may receive a special royalty wherethe public interest will be served thereby.

3. Scope of License Grant-The terms and conditions set forth above do not extend to the index of thisdocument.

(For further explanation, see the Policy Concerning the Adoption, Printing, and Publication of NFPADocuments, which is available upon request from the NFPA)

8/00

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:13 2010

Page 20: rss - nioec. راحي سيستم هاي اعلام... · PDF file12-15,2000,in orlando,fl. ... std.nfpa 121-engl 2001 .. 6474446 0595581 936 .. 121-4 fire protection for self-propelledand

pss: 22921500-0912.245.1159

STD.NFPA 121-ENGL 2001 .. 6474446 0595595 420 ..

mNFPA'

II\lTEfl:tMTIONAl

Copyright by the National Fire Protection AssociationTue Feb 09 14:54:13 2010