ROXTEC Resilient Mechanical Bulkhead Pipe Transits for Navy Applications
NSRP All-Panel ConferenceMarch 12-14, 2019
Sara ThomasLead Project Engineer
![Page 2: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/2.jpg)
HUNTINGTON INGALLS INDUSTRIES PROPRIETARY
2
Project Overview - Introduction
Photo taken with permission from Roxtec.com
Goal: To establish whether
commercially available resilient
mechanical bulkhead pipe transits
are suitable for US Navy
applications and quantify the
benefits for their use.
![Page 3: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/3.jpg)
HUNTINGTON INGALLS INDUSTRIES PROPRIETARY
3
Project Overview - Background
Ship
Shop
Creation of Pipe Details
Installation of Pipe Details
![Page 4: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/4.jpg)
4
Project Overview - Background
Photos taken with permission from Roxtec.com
![Page 5: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/5.jpg)
5
Tasks
• Task 1 - Evaluate advantages and disadvantages for various product options over the life of a ship
• Task 2 - Demonstrate shipyard producibility
• Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits
• Task 4 – Summarize results of shock and vibration testing representative fittings in various applications
• Task 5 - Pressure test after shock tests
• Task 6 - Recommend implementation of best practices and consolidation of findings
• Task 7 - Publish a white paper of results and present white paper to NSRP Panel
![Page 6: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/6.jpg)
6
Task 1 – Initial Evaluation
ROXTEC Model Basic Description
RS Seal Split seal for a single metal pipe
RS OMD Seal Split seal for a single metal pipe
SPM Seal Single piece seal for a single metal pipe
RS X Seal Non-welding seal for single metal pipe
R X Seal Non-welding seal for multiple metal pipes
R Frame Circular frame with packing to seal multiple metal pipes
S Frame Rectangular frame with packing to seal multiple metal
pipes
Table 1.1: ROXTEC Models from 2016 ROXTEC Catalog
![Page 7: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/7.jpg)
7
ROXTEC products have both positive and negative attributes that impact its use on the ship.
• Pressure Rated, fire rated, certified to
American Bureau of Shipping Standards
• Structural Compensation
• Prevention of galvanic corrosion
• Thermal Insulation
• Life-cycle testing
Task 1 – Initial Evaluation
ROXTEC Model Gas Tightness
(psi)
Water Tightness
(psi)
RS Seal 58 87
RS OMD Seal 58 87
SPM Seal 14.5 21.75
RS X Seal 58 87
R X Seal 58 87
R Frame 58 87
S Frame 58 87
Table 1.2: ROXTEC Model ABS Certified Pressure Ratings
![Page 8: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/8.jpg)
8
Task 1 – Initial Evaluation
RS Seal RS OMD Seal
SPM Seal RS X Seal
Photos taken with permission from Roxtec.com
![Page 9: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/9.jpg)
9
Task 1 – Initial Evaluation
R X SealR Frame
S Frame
Photos taken with permission from Roxtec.com
![Page 10: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/10.jpg)
10
Slide Title
This NSRP task will primarily focus on the
RS, RS OMD, and SPM Seal.
RS Seal RS OMD Seal SPM Seal RS X Seal R X Seal
R Frame S Frame
Photos taken with permission from Roxtec.com
![Page 11: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/11.jpg)
11
Task 2 – Demonstrate Shipyard Producibility
![Page 12: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/12.jpg)
12
Task 2 – Demonstrate Shipyard Producibility
ROXTEC
Products
Steps 1-3
(minutes)
Step 4
(minutes)
Total time
(minutes)
RS OMD:
1”NPS
9:30 10:25 19:55
RS: 6” NPS 5:09 9:05 14:14
RS: 3” NPS 1:33 8:04 9:37
RS: 1” NPS 2:50 7:57 10:47
Table 2.1: Feasibility Test Time Records of RS and RS OMD Seals
Steps 1-3 are to size the Roxtec seal, lubricate the sleeve and seal, and fit the seal onto
the pipe.
Step 4 is for tightening of the bolts using an Allen wrench
![Page 13: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/13.jpg)
13
Task 2 – Demonstrate Shipyard Producibility
Sketch of Potential Utilization of JigLubricant Container
![Page 14: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/14.jpg)
14
Task 2 – Demonstrate Shipyard Producibility
ROXTEC Product Total time (minutes)
SPM: 3” NPS 6:00
SPM: 6” NPS 11:14
Table 2.4: Feasibility Test Time Records of SPM Seals
![Page 15: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/15.jpg)
15
Task 2 – Demonstrate Shipyard Producibility
Exposed SPM Seal Rubber Tightening the SPM seal around the pipe before fixing
the entire assembly to the bulkhead
![Page 16: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/16.jpg)
16
Task 3 – Fire, Smoke, and Toxicity Qualifications
• MIL-DTL-24705B, “General Specification for Penetrators, Multiple Cable, Electric Cable”
• NSTM 505 extension to pipe transits
• RS and RS OMD pipe transits are equivalent to their cable transit counterparts
• Fire stop test performed for RS and RS OMD seals as cable transits
• SPM seals differ from the RS and RS OMD and have not been qualified.
• For any of the ROXTEC products to become qualified for use on Navy ships, a letter to request approval for use would have to be sent to NAVSEA.
![Page 17: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/17.jpg)
17
Tasks 4&5 – Shock and Vibration/Pressure Testing
Typical Apparatus of Confidence Test Specimen
![Page 18: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/18.jpg)
18
Tasks 4&5 – Shock and Vibration/Pressure Testing
Flange Separation of RS 68, 0 lbs. added weight,
hammer dropped from 5ft
“Telescoping” of RS OMD, 10 lbs. added weight, hammer
dropped from 5ft
![Page 19: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/19.jpg)
19
Tasks 4&5 – Shock and Vibration/Pressure Testing
RS OMD 150, NPS 4 in
Added Weight
(lbs.)
Height of Drop
(feet)
Slippage (inches)
30 5 3/32
40 5 5/32
60 5 0
RS OMD 150 Test Results
RS 150, NPS 4 in
Added Weight
(lbs.)
Height of Drop
(feet)
Slippage (inches)
30 5 8/32
40 5 4/32
60 5 5/32
RS 150 Test Results
![Page 20: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/20.jpg)
20
Task 6 – Final Evaluation and Recommendations
NNS recommends the RS seal and the RS OMD seal as the best alternatives for Navy shipboard use.
RS Seal
- Split design for easy
installation/replacement
- Pipes must be centered
during assembly
- Requires a Roxtec
specific sleeve
RS OMD Seal
- Split design for easy
installation/replacement
- Can be used with sleeves not
manufactured by Roxtec
- Pipes must be centered
during assembly
SPM Seal
- Complete no-weld solution
- Single piece design
- Installation limited to
thickness of the bulkhead
- Requires further testing
for fire stop test
Photos taken with permission from Roxtec.com
![Page 21: ROXTEC Resilient Mechanical Bulkhead Pipe …...2019/03/06 · •Task 3 - Extend fire smoke and toxicity qualifications from wire-way multi-cable transits •Task 4 –Summarize](https://reader034.vdocuments.site/reader034/viewer/2022042409/5f26368a9adadc5c182327ef/html5/thumbnails/21.jpg)
21
Task 6 – Final Evaluation and Recommendations
Recommended Further Evaluation
• Shock and Vibration testing needs to be completed
• Service Life – need for life-cycle testing
• Structural concerns
• Thermal Insulation
Photo taken with permission from Roxtec.com
NNS recommends further evaluation as well to understand all the possible uses of the Roxtec products.