OMT Software User Manual
Repeater Operation & Maintenance Terminal
OMT Software User Manual
FOR REFERENCE ONLY. SUBJECT TO CHANGE WITHOUT NOTICE.
1 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
CATALOGUE
1 OVERVIEW...............................................................................................................................3
2 USER GUIDE .......................................................................................................................... 3
2.1 Configure....................................................................................................................................................... 4 2.1.1 Serial port setting for remote connection ............................................................................................ 4 2.1.2 Local serial port setting ........................................................................................................................ 5
2.2 Visit ................................................................................................................................................................ 5 2.2.1 Click ‘Visit’ to pop up menu as Figure 8 ............................................................................................. 5 2.2.2 Connect................................................................................................................................................... 5 2.2.3 Operation of local mode........................................................................................................................ 8 2.2.4 Operation of SMS mode...................................................................................................................... 14 2.2.5 Operation of SMS mode...................................................................................................................... 15
2.3 Advanced Settings ...................................................................................................................................... 16
2.4 Help.............................................................................................................................................................. 18
2.5 Notes for remote communication .............................................................................................................. 18
2 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
1 Overview
Repeater operation & maintenance terminal (OMT) interact with the repeater to set and lookup its status and
RF parameters. It can display alarms real-time. OMT can set local connection, wireless data connection or
SMS connection with the device for operation and maintenance at any time, or at any location.
OMT and repeater connection topology:
Figure 1
OMT
Computer
Laptop
Repeater
RS232
Repeater
OMT
Computer
Laptop
Data SMS
RS232
Local mode Remote mode
2 User Guide
Start the application, The top menu are ‘Configure’, ‘Visit’, ‘Advanced’ and ‘Help’.
Figure 2
3 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
2.1 Configure
Click ‘Configure’ menu. Configuration items pop up as Figure 3:
Figure 3
2.1.1 Serial port setting for remote connection
a) Click ‘Remote Connection’. As Figure 4:
Figure 4
b) Select the serial port for communications, for example, ‘COM1’. Then click the next button ‘Port …’. As
Figure 5:
Figure 5
c) The default setting is usually used. Click ‘OK’ to return..
d) On ‘Remote Connection’ dialog box, modem initiate string can be specified in ‘Modem Init’ text box. The
default modem initiate string is ‘ATE1V1S0=2’, which set the modem to echo mode, answer the incoming call
on the second ring and auto-answer mode. Click ‘Default’ button can set the default value, As Figure 6.
e) When the SMS center number is not specified in the SIM card in the wireless modem, user shall specify
4 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
the SMS center number in the ‘SMS center number’ text box:
Figure 6
2.1.2 Local serial port setting
a) Click ‘Local Setting’. As Figure 7:
Figure 7
b) Local connection only needs setting on the serial ports. Other operations are same as ‘remote connection’.
Notice: all settings are saved in the configuration file. As far as the serial port or the device doesn’t
change, user needn’t to do the setting again for the next time.
2.2 Visit 2.2.1 Click ‘Visit’ to pop up menu as Figure 8
Figure 8
2.2.2 Connect
a) Click ‘Connect’ menu item or the button on the toolbar. As the Figure 9:
5 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 9
b) Choose a connection mode, which can be ‘Local’, ‘SMS’ or ‘Data’. Then user shall select the repeater to
connect. If the repeater is listed on the dialog box, user can highlight the item then click ‘Connect’. Otherwise,
user shall add the repeater in the list. The button ‘Set’ is used to modify repeater information. Click the button
‘Add’. The following dialog box pops up:
Figure 10
‘Repeater Name’ is to identify the repeater. If the OMT use ‘Remote’ method to connect repeater, user must
specify the ‘Phone Number’.
6 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Whatever the connection mode is used, ‘Repeater ID’ and ‘Device ID’ must be specified, which is a unique
number to identify the repeater in the network. ‘Repeater ID’ ranges between 1 and 4294967295, which
Repeater Operation Management Center software (OMC) assign after the repeater is available for service. It
shall be set to 0 in the stage of installation. ‘Device ID’ is for component device in co-frequency repeater. It
shall be set to the default value: 255 for other types of repeaters. User can specify the type of repeater on
dropdown list box of ‘Repeater Type’.
c) For example, user select ‘Channel selective repeater’ as repeater type, as Figure 11.
Figure 11
Finish the setting. As the following figure:
Figure 12
Click ‘OK’ button, an item is added into the list. As following figure:
7 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 13
Click ‘Set’ button can modify the parameters for the selected repeater. The popup dialog box is as same as one
in the Figure 6. Click ‘Delete’ button to delete a profile of repeater connection. Click ‘Connect’ button will
connect to a selected repeater.
Notice: These settings are saved in the configuration file. User needn’t to do the setting again for the next
time.
2.2.3 Operation of local mode
We take an example in the next section to show how to use OMT, which attached Channel selective repeater in
local mode.
a) User shall have a RS232 cable to connect repeater with the computer. If the computer isn’t outfit a serial
port, user can use a USB-to-Serial cable for this purpose.
Main window is as the following:
8 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Get one by one
Figure 14
b) There are two tabs in the main window: ‘Basic INFO’ and ‘Engineering parameter’. User can click the
title to switch tab.
‘Engineering parameter’ Tab:
Only 2 types of actions can be performed: ‘Get’ and ‘Set’.
Get: Click ‘Get’ button to query the value from the repeater.
Set: Not all parameters for repeater can be modified. A ‘Set’ checkbox follows a parameter which user
can modify. Check the checkbox, and input value into the textbox, then click ‘Set’ button to modify the
parameter.
9 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 15
c) The ‘Basic INFO’ tab is used as following:
i. Click ‘Get’ button to query the respective parameters. As figure 14. User can click ‘Get All’ button on the
bottom of the window the get all parameters from the repeater while OMT send multiple query command to it.
As Figure 16.
10 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 16
l
ii. After clicking ‘Get All’:
11 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
Get al
OMT Software User Manual
Figure 17
iii. Setting Parameters. For example, set the value for gain in uplink and downlink:
As Figure 17, repeater maximum gain is 88dB. The gain is set to 70 dB (Deduct 18 dB attenuation from
88 dB). To set the gain to 80 dB, as following:
Check ‘Set’ checkbox next to Uplink/downlink attenuation value. Then input the value in the attenuation
textbox, as the following figure:
Figure 18
Input 8 into uplink/downlink attenuation textbox, as the following figure:
12 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 19
After inputting the value, click ‘Update’ button on the bottom of the window. As the following figure:
Figure 20
When the setting is applied successfully, OMT will popup an information window. As following:
13 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 21
It indicates setting ATTN value successfully. Otherwise, it will prompt the dialog box indicate the
operation failed.
Notice: when user input the wrong ID to connect repeater, all operation will be failed. System will
prompt error message as following:
Figure 22
To work with the repeater, user can set the ‘Repeater Id’ and ‘Device Id’ same as the repeater connection
setting (Figure 10). As Figure 23:
Figure 23
iv. Other operations are same.
2.2.4 Operation of SMS mode
As Figure 13, once using ‘SMS’ mode to connect repeater, user shall connect the computer with the cellular
phone or wireless modem. User also need set the communication parameters for remote connection. Please
check the previous section ‘serial port setting for remote connection’ for the relevant instruction. Other
operations are same as Local mode. But remote connection will result in slow response for every command. In
14 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
ordinary circumstance, it takes between 30 and 60 seconds for the repeater to respond a command. So user
shall commit ‘Get’ and ‘Set’ action one by one to improve response speed.
The message window will indicate short message sent successfully when the command is executed
successfully. As Figure 24:
Figure 24
2.2.5 Operation of SMS mode
Data mode is similar with SMS mode. Data mode requires the computer connect with cellular phone or
wireless modem. It also requires remote connection setting. Committing ‘Get’ and ‘Set’ action one by one is
also recommended to improve response speed.
The difference between Data mode and SMS mode is: in ‘Data mode’, after clicking ‘connect’ button, OMT
will dial up immediately. As the following figure:
Figure 25
After being connected successfully, the main window shows.
a) Using dial up, connection is difficult to setup and data communication is slow and unreliable. User can
click the ‘Dial up’ button in the toolbar to redial when the dialup connection is disconnected. As the following
figure:
Figure 26
b) User can click ‘Hang up’ button to hang up the connection. As the following figure:
15 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 27
c) User can click button to force disconnecting when the system has no response to ‘hang up’ command. As
the following figure:
Figure 28
d) Disconnecting
User can click ‘Disconnect’ menu or the button ‘Disconnect’ in the toolbar to disconnect the dialup connection
and close the repeater information window. As the following figure:
Figure 29
2.3 Advanced Settings
The menu has the following functions:
Figure 30
a) Software downloading:
Figure 31
Select the file to download. Then click ‘Download’ button to start software update. Click ‘Cancel’ button to
16 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
cancel download. Software downloading is as the following figure:
Figure 32
A message box will pop up after downloading successfully. Then repeater reboot.
b) CPU reset
Click ‘CPU Reset’ button to reboot repeater. The function is similar ‘Reset’ button on PC.
c) Repeater Clock
Figure 33
It is convenient for user to lookup and to update the repeater clock on the dialog box.
d) History Alarm
User can view the history alarm kept on the repeater. As the following figure:
17 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 34
Click ‘Delete’ button to delete the history alarms in the repeater.
2.4 Help
Click ‘help’ to open user guide.
2.5 Notes for remote communication
a) The system has 2 modes for remote communication: SMS mode or Data mode. System couldn’t transfer
from one mode to another automatically. User can send command to switch the working mode. Working with
local mode, user can switch arbitrarily. However, in remote mode, user shall know which mode he/she working
with. Then he/she use command to switch the system from one to another. For example, user works in SMS
mode. He/she shall use OMT to send a SMS command to switch the working mode to data mode. Repeater
receives the SMS. If repeater accept the command, it reply a successful setting SMS. After the message is sent
successfully, repeater is switched to data mode. Then, user shall use data mode to query and set parameters in
the repeater.
b) To remotely control, the specified phone number shall be same as ‘MOC Query/Control phone NO.’
Otherwise, user can’t set parameter but query parameter in the repeater. As the following figure:
18 of 19 Rosenberger Asia Pacific Electronic Co., Ltd
Tel: +86 10 80481995 Fax: +86 10 80482438
OMT Software User Manual
Figure 35
c) In SMS mode, ‘SMSC phone No.’ in ‘Engineering Parameter’ tab must be specified correctly. Otherwise
repeater can’t work., As the following figure:
Figure 36
d) In data mode, OMT software has 1 minute timing protection on the packages sent out. When data
connection is established, we suggest user wait about 20 seconds to execute commands against repeater. If the
system has no response, user shall wait more than 1 minute for OMT.
e) For closed repeater, user shall reset cut the power supply of the repeater after inserting SIM card.
Thank you very much for your support!