rosemount analytical inc. liquid, combustion & process gas, gc and flame & gas products...
TRANSCRIPT
Rosemount Analytical Inc.Rosemount Analytical Inc.
Liquid, Combustion & Process Gas, GC and Flame & Gas Products
Presented by:
[File Name or Event]Emerson Confidential27-Jun-01, Slide 2
US Operating LocationsUS Operating LocationsFlame & GasCalgary, AB
GCs & ServiceHouston, TX
Liquid ProductsIrvine, CA
Combustion & PGASolon, OH
[File Name or Event]Emerson Confidential27-Jun-01, Slide 3
Wide Range of Analytical Measurements
• pH/ORP• Conductivity
- Toroidal- Contacting
• Turbidity• Amperometric
- Dissolved Oxygen- Chlorine- Ozone
• Wet Chemistry
• Combustion Flue Gas Analyzers
- In Situ Oxygen• Continuous Gas
Analyzers- CO, CO2
- O2
- NOx, SOx• Process & Gas
Analysis Systems
The World's Premier Supplier of Instrumentation and Systems for Continuous On-line Gas & Liquid Analytical Measurement and Control
GCs& Service
LiquidAnalytical
Rosemount Analytical
Combustion & PGA
Flame& Gas
• GCs- Industrially
hardened- Transmitter style
• Field Service- Demand- Startup- PM
• Flame Detectors- IR, UV- Hydrogen
• Gas Detectors- Toxic- Combustible
• Smoke, Oil & Mist• Leak Detectors
Rosemount Analytical Inc.
Liquid Analytical Products
Rosemount Analytical Inc.
Liquid Analytical Products
[File Name or Event]Emerson Confidential27-Jun-01, Slide 5
Rosemount Analytical
LiquidBegins
Division Reporting
1979Universal Interloc
Founded
1963
Rosemount Acquires Universal Interloc - Uniloc
Cedar GroveConsolidation
Into Irvine Begins
A. Beckman invents
pH Meter
Industrial Instruments Founded
1935
1938
1965Beckman
Instruments acquires Industrial
Instruments - creates Cedar Grove Division
19841993 1996
Liquid Products - 77 Years of ExperienceLiquid Products - 77 Years of Experience
Emerson Acquires Beckman Instruments
(Cedar Grove Division) From SmthKlineBeckman
[File Name or Event]Emerson Confidential27-Jun-01, Slide 6
Served IndustriesServed Industries
Chemical Process Drinking Water Environmental Monitoring Food & Beverage Metals & Minerals Petroleum Refining Pharmaceuticals Power Pulp & Paper Semiconductors Textiles Waste Water
[File Name or Event]Emerson Confidential27-Jun-01, Slide 7
Liquid Instrument PlatformsLiquid Instrument Platforms
Model 56 Model 5081
Model 1056 Model 1066
Hig
h T
ier
Mid
Tie
r
2-Wire Transmitters4-Wire Analyzers
Multi-Parameter Dual Sensor Input 2 Current Outputs Large Graphic Display HART / Pf DP Multiple Languages Standard Diagnostics Agency Approvals Serves OEM Market
pH / Conductivity Wireless Enabled Wireless HART AMS Aware / EDDL Intrinsically Safe Multiple Languages Adv. Diagnostics Agency Approvals
Wireless TransmitterModel 6081
Model 775 Smart Wireless THUMTM Adapter
Wireless HART Upgrade Module
Compatible with Existing Base of HART Devices
Unlocks “Stranded Diagnostics” in HART Devices with Analog Only Wiring
First in Industry
Multi-Parameter 2 Current Outputs Back Lit Display HART AMS Aware / EDDL PID Multiple Languages Advanced
Diagnostics
Multi-Parameter HART / Ff AMS Aware /
EDDL Explosion Proof Multiple Languages Remote Controlled Agency Approvals
Multi-Parameter HART / Ff AMS Aware /
EDDL Multiple Languages Agency Approvals
[File Name or Event]Emerson Confidential27-Jun-01, Slide 8
pH and ORP SensorspH and ORP Sensors
389
3900
396P
396R
396
TF396
•396P, Coating and Wastewater probe, Insertion•396R, Coating and Wastewater probe, Retractable•3900, General Purpose probe•389, Ruggedized probe for poisoning applications•TF396, Non-Glass pH probe•3800, Steam Sterilizable for Pharma/Biotech•3200HP High Purity pH (power industry)•3500, High Temperature, Poisoning, Coating probe
3800
3200HP3500
[File Name or Event]Emerson Confidential27-Jun-01, Slide 9
400
401
402 403
Contacting Conductivity Sensors Contacting Conductivity Sensors For Accurate Low Range Conductivity• Configurations:
• Screw-In...Model 400/401• Retractable...Model 402• Sanitary...Model 403• Low Flow Cell...Model 404
• Low Conductivity Measurement: • Ultrapure to Surface Water • Cell Constants of 0.01/cm, 0.1/cm and
1.0/cm
• High Conductivity Measurement:• 4 electrode (401) 404
[File Name or Event]Emerson Confidential27-Jun-01, Slide 10
Toroidal Conductivity SensorsToroidal Conductivity Sensors
Configurations:• Flow Through…Models 222/242• Insertion/Submersion…Models 226/228• Sanitary…Model 225/245
PerlickTri-ClampFlow Through
225
226 228
242
222
Ideal for Dirty, Coating, High Conductivity
• Minimal Maintenance• Corrosion Resistant Materials• Suitable for Clean-In-Place, Coating,
Viscous, or Abrasive Applications• % Concentration Measurements
245
[File Name or Event]Emerson Confidential27-Jun-01, Slide 11
Amperometric Sensors - 499A FamilyAmperometric Sensors - 499A FamilyFull Line of Measurement Choices:
• Free Chlorine Model FCL • Total Chlorine Model TCL• Monochloramine Model MCL System• Dissolved Oxygen (ppm)
• Auto Air Blast Cleaning System• Trace Dissolved Oxygen (ppb)• Dissolved Ozone
• Fast, Easy Maintenance• Twist-off Membrane
• High Current Output• Versatile Mounting, Insertion, Submersion, Low
Flow Mounting ConfigurationsAuto Air Blast System
Model DO-03/04
[File Name or Event]Emerson Confidential27-Jun-01, Slide 12
Free Chlorine: Model FCL Packaged SystemFree Chlorine: Model FCL Packaged System
No Reagent or Conditioning RequiredRange: 0- 10 ppm (0-20 Dual Slope Cal)
Automatic Correction to pH 10.0Two versions
•FCL-01 chlorine sensor only•FCL-02 chlorine with pH correction
Constant head flow controller--no valves or pressure regulators to worry about •Minimum flow of 3 gph (80 gph Max)•Everything mounted on a back plate•Sensor cables pre-wired to the analyzer
Choice of Four Instruments: Model 1055, 54eA, Xmt-A, 5081A
chlorine sensor pH sensor
inlet drainflow controller
[File Name or Event]Emerson Confidential27-Jun-01, Slide 13
Constant head flow controller
Sensor
Delivery Pumps
Inlet Drain
Measure Total Chlorine System Model TCLMeasure Total Chlorine System Model TCL
*Chloramines: MonocChloramine, DiChloramine and TriChloramine
Accurately Measures Total Chlorine, Range 0 – 20 ppm
Total Chlorine = Free Chlorine + Combined Chlorines (Chloramines*)
Low Maintenance Design
Simple Overflow Weir: Correct Flow Rate
Low Flow Rate 6 GPD (0.25 GPH or 15 mL/Min)
Readily Available Reagent: White Distilled Vinegar
5 Gallons Lasts 2 Months: Potassium Iodide in Vinegar
Choice of Four Instruments
[File Name or Event]Emerson Confidential27-Jun-01, Slide 14
Distribution Monitoring: Water Quality SystemComplete Systems: Sensor, Cable, and Instrument
Measurements Can Include:
• pH
• ORP
• Conductivity
• Temperature
• Chlorine: Free, Mono, Total
• Dissolved Oxygen
• Turbidity
• Particle Index
Choice of Four Instruments: Model 1055, 54eA, Xmt-A, 5081A
EPA/ETV Test Verified Performance
[File Name or Event]Emerson Confidential27-Jun-01, Slide 15
Quick Cable-to-Sensor ReleaseQuick Cable-to-Sensor ReleaseVP Connector - Variopol Option• Replace the Sensor Without Running New Cable
• Rugged Construction with Quick Cable Connector
• Eliminates Cable Twisting• Available on all Sensors, Except Toroidal Conductivity
pH Sensors
Conductivity Sensors
Amperometric Sensors
Quick Sensor Cable Disconnect
[File Name or Event]Emerson Confidential27-Jun-01, Slide 16
Clarity II Online Turbidimeter Measuring SystemClarity II Online Turbidimeter Measuring System
• Superior Low Level Accuracy for Filtration at 0-1 NTU• Single or Dual Sensor Input• USEPA 180.1 or ISO 7027 Approved Method• Advanced Lamp Board Diagnostics and Adjustment• Full Featured NEMA 4X Analyzer with Six Languages• Total Suspended and Turbidity Measurement• 0 - 200 NTU Range• Sample Flow: Pressurized or Flow Through• Two Stage Debubbling Chamber• Three Calibration Methods - Including One Point Method• Reduced Formazin Required for Calibration• Class I Div 2 Approval• Two 4-20 mA Outputs (One per Sensor)• Three Adjustable Alarms (Optional Alarm Board)
[File Name or Event]Emerson Confidential27-Jun-01, Slide 17
Wet Chemical AnalysisWet Chemistry Analyzers
• Ammonia• Silica• Sodium• Phosphate• Hydrazine• Chromium• Fluoride
• Continuous Flow Wet Chemistry Measurement• Colorimetric or Ion Specific Electrode Method• Optional Multi-Stream (Up to 6 Sample Lines)• 4-20 mA and 0-5 V Outputs• Pre-Packaged Reagent
[File Name or Event]Emerson Confidential27-Jun-01, Slide 18
Wet Chemistry AnalysisWet Chemistry Analysis Sample Pump Module Available with annual
Service contract Swap the pump module
for a factory reconditioned
unit once a year Arrives with years supply
of packaged reagents
Rosemount Analytical Inc.
Combustion & Process Gas Analyzers
Rosemount Analytical Inc.
Combustion & Process Gas Analyzers
[File Name or Event]Emerson Confidential27-Jun-01, Slide 20
Combustion & PGACombustion & PGA Formed through Business Consolidations
– 1984 – Acquired Beckman Instruments– 1990 – Acquired Leybold– 1990 – Rosemount acquired Westinghouse– 1993 – Consolidated Gas & Liquid Analyzer Businesses– 1996 - PAD became a Business Unit
Current locations– Solon, Ohio– Houston, Texas– Fromex- Nuevo Laredo Mexico– Hasselroth, Germany– Wessling, Germany
Headcount totals 356
Nuevo LaredoComb. & PGA
Mfg10,500 ft2
Nuevo LaredoComb. & PGA
Mfg10,500 ft2
Solon, OhioHeadquarters
20,000 ft2
Solon, OhioHeadquarters
20,000 ft2
HasselrothPGA Mfg, Repair
26,000 ft2
HasselrothPGA Mfg, Repair
26,000 ft2
HoustonSpares & Repair
3,000 ft2
HoustonSpares & Repair
3,000 ft2
[File Name or Event]Emerson Confidential27-Jun-01, Slide 21
Product OfferingProduct Offering
Combustion
Oxygen Analyzers:• 6888 O2
• Oxymitter 4000• 5081 FG (High Temperature)• OCX (O2 & COe)
Other:• OPM (Opacity)• CCO 5500 (In situ CO)• PowerVue (Damper Drives)
Continuous Gas
Process & Environmental Analyzers:• MLT Series Analyzers• X-STREAM PGA Series• 951C & 400A Single
Channel GP Analyzers
Systems
In-house integration capabilities in all World Areas:
• North & South America – Solon, OH
• Europe & Middle East – Wessling, Germany
• AP – Singapore, China & India
[File Name or Event]Emerson Confidential27-Jun-01, Slide 22
Combustion Analysis & Boiler Control ProductsCombustion Analysis & Boiler Control Products
Damper Drives
5081
OCX
Oxymitter
6888
Xi Electronics
[File Name or Event]Emerson Confidential27-Jun-01, Slide 23
Combustion ApplicationsCombustion Applications
Gas, Oil & Coal Fired Boilers
Kilns
Refineries & Petrochemical Plants
[File Name or Event]Emerson Confidential27-Jun-01, Slide 24
Analyzers for Combustion ControlAnalyzers for Combustion ControlThe primary purpose of combustion analyzers is to maintain the optimum ratio between the fuel sent to the burner and the oxygen required to burn that available fuel. The analyzer measures oxygen. The damper drive controls the air flow to or from the burner.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 25
Process Gas AnalyzersProcess Gas Analyzers
X-STREAM PGA
MLT/NGA
951C/400A
[File Name or Event]Emerson Confidential27-Jun-01, Slide 26
Process Analyzer OverviewProcess Analyzer Overview Multi-Bench Analyzers
– X-STREAM Series– MLT Series
(NDIR/UV/VIS, PO2, EO2, TC)
Hydrocarbon Analyzers– 400A (FID)– NGA FID/HFID
NOx Analyzers – 951C (CLD)– NGA CLD/WCLD
CurrentLoop
Magnet
N2 filled glass sphere
SuspensionMirror
Paramagnetic
Thermal Conductivity
Chemiluminescence
Flame Ionization
NDIR/UV/VIS Photometry
[File Name or Event]Emerson Confidential27-Jun-01, Slide 27
Process Analyzer OverviewProcess Analyzer Overview Smart Capabilities
– Diagnostics for ease of maintenance– Easy to use menus– Digital communication protocols available
Wide Variety of Housings– Certifications for all general purpose &
hazardous area locations Multiple Optical Benches Available
– Up to 5 measurements in a single analyzer– Mix and match any combination of benches
Common Parts – Reduces spare parts requirements and
analyzer downtime
[File Name or Event]Emerson Confidential27-Jun-01, Slide 28
Engineered Systems CapabilitiesEngineered Systems Capabilities
Engineered systems meet specific customer requirements for process measurements or environmental reporting.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 29
Engineered Systems CapabilitiesEngineered Systems Capabilities
OBJECTIVES
• Eliminate/Reduce shelter requirements
• Increase Monitoring Flexibility• Meet Hazardous Area
Classifications
Wall Mount SampleConditioning Enclosure
Sample Probe
ROOF LEVEL
GROUND LEVEL
UnheatedLine or HeatTrace
Heated Sample Line
Smart Analyzer
[File Name or Event]Emerson Confidential27-Jun-01, Slide 30
Engineered Systems CapabilitiesEngineered Systems Capabilities Simplified flow schematics for Continuous Emissions
Monitoring Systems (CEMS) & standard components help reduce engineering costs.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 31
Engineered Systems CapabilitiesEngineered Systems Capabilities
Custom designed sample systems and cabinets allow flexible installations for customer specific needs.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 32
Engineered Systems CapabilitiesEngineered Systems Capabilities
All systems require various amounts of engineering.
Consideration for ambient conditions, measurement locations and installation area classifications must be reviewed prior to system design.
This package has been designed with purges for hazardous area locations.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 33
Engineered Systems CapabilitiesEngineered Systems Capabilities Flexibility allows Rosemount Analytical to design
systems from custom built to modular. From ‘Walk In’ style fully engineered shelters to modular systems that can help reduce installation costs and cost of ownership.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 34
X-STREAM Analyzer
with Sample System
Sample Tap in Process Unit
Analyzer Shelter with Process Analyzers
Conventional Approach vs Emerson Transmitter
Heated Sample Line
[File Name or Event]Emerson Confidential27-Jun-01, Slide 35
Product Applications & IndustriesProduct Applications & Industries
Chemical/Petrochemical– Tank blanketing
(safety measurement)
– Hydrogen plant – Ammonia, urea – Ethylene and
propylene
Refining– Naphtha isomerization– Catalytic reforming– Hydrocracking– FCCU– Sulfur recovery– Hydrocarbon compressor– Marine unloading/vapor
recovery– Feed stock heaters
[File Name or Event]Emerson Confidential27-Jun-01, Slide 36
Metals & Mining– Furnaces– Heat treating
Product Applications & IndustriesProduct Applications & Industries Power
– Combustion Control– CEMS– Hydrogen cooling
– Coal Gasification
[File Name or Event]Emerson Confidential27-Jun-01, Slide 37
Product Applications & IndustriesProduct Applications & Industries Oil & Gas
– Natural Gas Pipeline Air Separation
– Air Separation– Gas Bottling
Cement– Kiln Gases & Combustion
Control Automotive
– ICEE
Biogas, Food & Beverage & More….
Rosemount Analytical Inc.
Gas Chromatographs
Rosemount Analytical Inc.
Gas Chromatographs
[File Name or Event]Emerson Confidential27-Jun-01, Slide 39
What is gas chromatography?What is gas chromatography? Gas chromatography is an instrumental method for the
separation and identification of a compound
The sample is then carried through a separating column by an inert gas, such as helium
The sample is introduced to the GC after flowing through a sample conditioning system.
The sample is detected as a series of peaks via GC software as components leave the column and pass over the detector.
[File Name or Event]Emerson Confidential27-Jun-01, Slide 40
GC CHARACTERISTICS The broadest range of chemical
measurements High sensitivity (ppb to %) Multiple measurements in a single
analysis Flexibility to choose desired
measurements Proven online technology since 1956 Users Believe in It.
Gas chromatography is a proven analytical technique used in a broad range of industrial applicationsGas chromatography is a proven analytical technique used in a broad range of industrial applications
Aromatic PlantEthylene Plant PipelineRefinery
APPLICATIONS Ammonia Plant 5 - 10 units Aromatic Plant 10 - 20 units Ethylene Plant 30 - 50 units Gas Processing Plant 15 - 20 units LNG Train 15 - 20 units Propylene Plant 20 - 25 units Refinery 20 - 25 units Urea Plant 3 - 5 units Vinyl Chloride 5 - 10 units Gas Power 2 per Turbine Air Production 5 - 10 per
Plant Iron/Steel 3 - 5 per
Plant Pipeline 1000s of
units
[File Name or Event]Emerson Confidential27-Jun-01, Slide 41
Gas ChromatographsGas Chromatographs 80+ years of experience
– Beckman / Rosemount / Emerson
(1956 / 1983 / 1976)– Honeywell / Daniel / Emerson
(1968 / 1978 / 2000)
Over 11,000 online gas chromatographs installed worldwide
Worldwide service and support Three GC Application/Support Centers
– Houston, Texas– Stirling, United Kingdom– Hasselroth, Germany
[File Name or Event]Emerson Confidential27-Jun-01, Slide 42
Typical ApplicationsTypical Applications
Btu / CV for Fiscal Metering Natural Gas Quality (H2S, O2, CO2)
Hydrocarbon Dewpoint Gas Processing (Excluding Gulf Area)
Natural Gas Process Ethylene Purity Refinery Fuel Gas (Btu/ H2S)
Refinery Flare Stack (HR-VOC) Refinery Cooling Tower (HR-VOC) Turbine Power Generators (WOBBE Index) Ammonia Plant (H2 purity)
Landfill Gas BTUs LNG Plants & Terminals (Quality & Purity) Gas Processing (Gulf Area only)
[File Name or Event]Emerson Confidential27-Jun-01, Slide 43
The Emerson GC differenceThe Emerson GC difference
Environmental chamber testing
Airless Oven Design
Diaphragm Valves
High-Sensitivity TCD
PLUSThe exclusive MON2000 Software
[File Name or Event]Emerson Confidential27-Jun-01, Slide 44
Emerson GC Product OfferingEmerson GC Product Offering
Model 700XA Model 500
MON 2000 / 2020Model 1500XA
Transmitter Style Design 24VDC or 110/220 VAC TCD/FID (Single or Dual) Micro-packed Columns Isothermal Oven Wall/Pipe/Floor Mount Serial/Modbus/Ethernet
communications
Field-mount Design 110/220 VAC TCD only Micro-packed Columns Isothermal (Single/Dual) Oven Integral or Remote Controller Serial/Modbus/Ethernet
communications
Air Bath Oven Design 110/220 VAC TCD, FID or FPD Micro-packed and Capillary
Columns Up to 8 Valves Free Standing/ Wall Mount Serial/Modbus/Ethernet
communications
Laptop/PC based diagnostics
Connects to GCs via Ethernet/Serial/Modem
Modbus Polling functions Display/Overlay
Chromatograms Display/Edit Application
Programs
[File Name or Event]Emerson Confidential27-Jun-01, Slide 45
Emerson Value in Fiscal MeteringEmerson Value in Fiscal Metering Energy, Flow, and Gas Quality Energy = Corrected Volume (From Flow Computer) X Heating Value
(From Gas Chromatograph) Tariff/Contractual limits
– Trace hydrogen sulfide, %CO2– Trace Sulfur– Hydrocarbon dew-point
1 2 3 5 6 89 10 114 7
C6+ Chromatogram
1 Btu error can cost nearly $50,000 a year in “lost” gas (Using 1020 Btu/scf & Volume of 20,000,000 scf/day with 0.1% error in Btu @ $6.00 / Dekatherm)
Our GCs offer the highest stated repeatability available
[File Name or Event]Emerson Confidential27-Jun-01, Slide 46
Emerson Value in Process ApplicationsEmerson Value in Process Applications
vs
Field-mount Process Gas Chromatographs provide greatly reduced cost of ownership by eliminating the need for expensive walk-in shelters. Project Costs can be reduced by 60+% with Ongoing Costs reduced by 50+%.
Conventional PGC Installation Emerson Field-Mountable PGC
Conventional GCs (3) $105KWalk-In Shelter $250KTOTAL COST $355K
Field-Mount GCs (3) $105K3-Sided Shelter $25KTOTAL COST $130K
Rosemount Analytical Inc.
Net Safety Flame & Gas
Rosemount Analytical Inc.
Net Safety Flame & Gas
[File Name or Event]Emerson Confidential27-Jun-01, Slide 48
Corporate ProfileCorporate Profile Net Safety Monitoring has been
an flame & gas detection industry leader for almost 20 years
Headquartered in Calgary, Alberta, Canada
Representation throughout Canada, the United States, Latin America, the Middle East, Europe, Russia, and the Asia/Pacific Region
Global Customer Service Centers — Calgary, Abu Dhabi, Houston, Beijing and Singapore
[File Name or Event]Emerson Confidential27-Jun-01, Slide 49
Product ProfileProduct Profile Net Safety Monitoring is a leader in the development
and manufacturing of:– Advanced Fixed Gas Monitoring and Flame Detection
Instrumentation– Ancillary Safety & Security Products
All certified explosion-proof for use in classified hazardous locations
Flagship products are approved to FM, SIL2, CSA, ATEX, ANSI-ISA/UL, GOST-R and INMETRO safety, technical and performance standards
Engineered for continuous performance in the most extreme environments
[File Name or Event]Emerson Confidential27-Jun-01, Slide 50
Manufacturing CapabilitiesManufacturing Capabilities 38,000 sq. ft. state-of-the-art Manufacturing and R&D facility ISO 9001:2008 Quality Management System Certified Committed to the “Lean Corporate Culture” — a highly efficient
and waste-free organization with a focus on continuous improvement of all processes relating to intelligent production and product quality
Advanced computer-controlled production of electronic circuit boards at our own manufacturing facility ensures strict quality control
Our ability to partner with end-users to match our products to meet specific application requirements is a unique value-add within the industry
[File Name or Event]Emerson Confidential27-Jun-01, Slide 51
Engineering and R&DEngineering and R&D State-of-the-art research, design, testing and engineering
facility
[File Name or Event]Emerson Confidential27-Jun-01, Slide 52
Customer ServicesCustomer Services Multilingual, highly-trained
service technicians are available 24/7/365
Global network of certified service partners
State-of-the-art test lab/calibration facility
Start-up and commissioning services
[File Name or Event]Emerson Confidential27-Jun-01, Slide 53
Primary Markets ServedPrimary Markets Served Onshore/Offshore Oil and
Gas Production Oil Refining, Transportation
and Distribution Petrochemical Food and Beverage Power Generation Semiconductor
Aviation Mining & Mineral Processing Pharmaceutical Waste Treatment Pulp and Paper Steel Manufacture Military Chemical
[File Name or Event]Emerson Confidential27-Jun-01, Slide 54
Global End-UsersGlobal End-Users
[File Name or Event]Emerson Confidential27-Jun-01, Slide 55
Flame DetectionFlame Detection
Ultraviolet / InfraredPhoenix Triple IR Ultraviolet Hydrogen
[File Name or Event]Emerson Confidential27-Jun-01, Slide 56
UV/IRS – Ultraviolet / Infrared Flame DetectorUV/IRS – Ultraviolet / Infrared Flame Detector Two Radiation Wavelengths Necessary for Alarm – minimize
false alarm events from lightning, welding, sunlight and radiation
Manual and automatic testing of optical surfaces – constantly monitors internal electronics
Field Programmable – Fine Tune Sensitivity and Time Delay Low Power and Wide Voltage Range — improves
performance, reduces installation and operation costs Available with sensors specially tuned to detect invisible H2
Hydrogen flame Full 120 Degree Field of View with Extended Range! Operating Range of -50°C to +75°C (-58°F to +167°F) CSA, ATEX, ANSI-UL/ISA, GOST-R, and INMETRO
approvals, FM Certified, SIL2 qualification by exida®
[File Name or Event]Emerson Confidential27-Jun-01, Slide 57
IR3S – PHOENIX Triple IR Flame DetectorIR3S – PHOENIX Triple IR Flame Detector NO EXTERNAL REFLECTOR - AUTOMATIC VISUAL INTEGRITY
unique feature greatly reduces maintenance and cost of ownership PROPRIETARY AUTOMATIC DIGITAL ZOOM TECHNOLOGY
advanced flame detection and false alarm immunity at all distances THREE PRECISELY TUNED INFRARED SENSORS – ultra fast
response, accurate flame detection, eliminates false alarms, farthest range
ENGINEERED FOR EXTREME ENVIRONMENTS — operating range of -50°C to +75°C with the lowest power consumption available
LOW POWER AND WIDE VOLTAGE RANGE — improves performance, reduces installation and operation costs
7 YEAR WARRANTY – best warranty in the industry GLOBAL APPROVALS – CSA, ATEX, ANSI-UL/ISA, GOST-R, and
INMETRO approvals, FM Certified, SIL2 qualification by exida® FIELD PROGRAMMABLE – Fine Tune Sensitivity and Time Delay MULTIPLE OUTPUT OPTIONS – Analog, Relay, RS485 Modbus,
HART
[File Name or Event]Emerson Confidential27-Jun-01, Slide 58
Millennium II SeriesMulti-Channel
Universal Transmitter
Millennium SeriesToxic & CombustibleTransmitter/Sensors
ECO-SENSE Series2-wire H2S Loop-powered
Transmitter/Sensor
Gas DetectionGas Detection
[File Name or Event]Emerson Confidential27-Jun-01, Slide 59
MILLENNIUM II Series – Smart Gas DetectorsMILLENNIUM II Series – Smart Gas Detectors Full Range of COMBUSTIBLE (Catalytic Bead &
Infrared) and TOXIC (Solid State NE-MOS & Electrochemical) Sensors
Market-leading Sensor and Transmitter Warranties Universal Transmitter - Mix and Match Any Pre-
calibrated SMART Sensor Full Graphic OLED Display – Visible In Any Lighting
Condition Four Display Languages – Intuitive Menu Operation Operating Range of -55°C to +85°C Low Power and Wide Voltage Range Long Range Sensor Separation (2000 ft +) ATEX, CSA, ANSI/UL/ISA, INMETRO and GOST-R
Approvals with FM Certification, SIL2 Analog, Relay, RS485 Modbus and HART
Communications
Millennium IISingle Channel
Millennium IIBASIC
[File Name or Event]Emerson Confidential27-Jun-01, Slide 60
Millennium APMAir Particle MonitorSmoke & Oil Mist
Detector
Banshee343Ultrasonic GasLeak Detector
FlameWatch IIVideo/Flame
Detection Combo
Ancillary Safety/Security ProductsAncillary Safety/Security Products
Explosion-ProofMotion Detector& Video Camera
[File Name or Event]Emerson Confidential27-Jun-01, Slide 61
Millennium RM2Rack MountController
Sales Gas Monitor (SGM)Inline H2S Sampling& Analyzing System
SafeGuard Controller16 Channel Master
Display System
Ancillary Safety/Security ProductsAncillary Safety/Security Products