rosemount 3051sam scalable pressure … · 2015-02-20 · certifies this drawing in accordance with...
TRANSCRIPT
REVISION ECO NO. APP'D DATE
REVISION TABLE
DESCRIPTION
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
MDR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
DRAWING NO.
TAG NO.
CUSTOMER DWG NO.
CAL.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
5.17[131]
4.51[115]
3.45[88]
4.20[107]
2.13[54]
7.72[196]
8.57[218]
1.10[28]
3/8/13PFRTC1056505AA
PRODUCE PRO-E FOR 3051SAM ERS
71D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
THE 3051SAM ERS PRIMARY TRANSMITTER WILL HAVE PLANTWEB HOUSING UNLESS REMOTE DISPLAYIS INCLUDED. WHEN A REMOTE DISPLAY IS INCLUDED THE PRIMARY WILL HAVE A JUNCTION BOX HOUSING.
THE 3051SAM ERS SECONDARY TRANSMITTER WILL ALWAYS HAVE A JUNCTION BOX HOUSING.
THE 3051SAM REMOTE DISPLAY (WHEN APPLICABLE ) WILL ALWAYS HAVE PLANTWEB HOUSING, SEE PAGE 7.
1.
2.
3.
NOTES:
1. ROSEMOUNT INC. CERTIFIES THIS DRAWING IN ACCORDANCE WITH ROSEMOUNT ENGINEERING SPECIFICATIONS AND ACCURATELY REPRESENTS THE EQUIPMENT FURNISHED.
2. .75 (19) IS REQUIRED FOR CLEARANCE TO REMOVE COVERS (EACH SIDE)
PLANTWEB HOUSING(PRIMARY)PLANTWEB HOUSING
SHOWN WITH OPTIONAL DIGITAL DISPLAY(PRIMARY)
JUNCTION BOX HOUSING (SECONDARY)INLINE OR COPLANAR TRANSMITTER
PLANTWEB OR JUNCTION BOX HOUSING
ROSEMOUNT 3051SAM SCALABLE PRESSURE TRANSMITTERCOPLANAR FLANGE PROCESS CONNECTION
CONDUIT CONNECTION(2 PLACES)
NAMEPLATE
BRACKETMOUNTING HOLES
(3/8-16 UNC)(2 PLACES)
FIELD TERMINALS(THIS SIDE)
DRAIN/VENTVALVE
DIGITAL DISPLAY COVER
CERTIFICATIONLABEL
COPLANAR FLANGEPROCESS CONNECTIONPER IEC 81518
FLANGEADAPTERS(OPTIONAL)
1/4-18 NPT PROCESS CONNECTION OR1/2-14 NPT WITH OPTIONAL FLANGE ADAPTERS.ADAPTERS CAN BE ROTATED TO PROVIDECONNECTION CENTERS OF 2.00 [51], 2.126 [54],OR 2.25 [57].
TRANSMITTERELECTRONICS(THIS SIDE)
SEE DRAWINGS 03151-6000 AND 03151-6001 FOR MOUNTING CONFIGURATIONS AND DIMENSIONS. SEE MANIFOLDDRAWINGS FOR MOUNTING DIMENSIONS AND CONFIGURATIONS WITH COPLANAR AND INLINE MANIFOLDS.
1.
1.
2.
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
4.51[115]
9.30[236]
5.17[131] 4.20
[107] 3.45[88]
72D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
ROSEMOUNT 3051SAM SCALABLE PRESSURE TRANSMITTERTRADITIONAL FLANGE PROCESS CONNECTION
PLANTWEB HOUSING(PRIMARY)
PLANTWEB HOUSINGSHOWN WITH OPTIONAL DIGITAL DISPLAY
(PRIMARY)JUNCTION BOX HOUSING (SECONDARY)INLINE OR COPLANAR TRANSMITTER
FLANGEADAPTERS(OPTIONAL)
DRAIN/VENTVALVE
TRADITIONAL FLANGE
TRANSMITTERELECTRONICS(THIS SIDE)CONDUIT CONNECTION
(2 PLACES)
NAMEPLATE
FIELD TERMINALS(THIS SIDE)
DIGITAL DISPLAY COVER
HOUSING ROTATIONSET SCREW
CERTIFICATIONLABEL
1/4-18 NPT PROCESS CONNECTION OR 1/2-14 NPT WITH OPTIONAL FLANGE
ADAPTERS. ADAPTERS CAN BE ROTATED TO PROVIDE CONNECTION CENTERS OF 2.00 [51], 2.126 [54], OR 2.25 [57].
1.
1.
2.
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
8.52[216]
3.45[88]
5.17[131]
8.14[207]
4.51[115]
73D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
PLANTWEB HOUSING(PRIMARY)
PLANTWEB HOUSINGSHOWN WITH OPTIONAL DIGITAL DISPLAY
(PRIMARY)
ROSEMOUNT 3051SAM PRESSURE TRANSMITTER COPLANAR FLANGE PROCESS CONNECTION WITH CAPILLARY AND DIRECT MOUNT SEALS
JUNCTION BOX HOUSING (SECONDARY)INLINE OR COPLANER TRANSMITTER 1.
1.
2.
SEE 01199-9500 SEAL TYPE 1 DRAWING FOR THE SPECIFIC DIMENSIONS ON THE AVAILABLESEALS. ALL SEALS AVAILABLE ON THE LOW SIDE.
SEE 01199-9500 SEAL TYPE 1 DRAWING FOR THE SPECIFIC DIMENSIONS ON THE AVAILABLESEALS. ALL SEALS AVAILABLE ON THE LOW SIDE.
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
5.17[131] 4.51
[115]
8.04[204]
1.50[38]
3.45[88]
74D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
PLANTWEB HOUSING(PRIMARY)
PLANTWEB HOUSINGSHOWN WITH OPTIONAL DIGITAL DISPLAY
(PRIMARY)
ROSEMOUNT 3051SAM PRESSURE TRANSMITTER IN-LINEPROCESS CONNECTION WITH CAPILLARY AND DIRECT MOUNT SEALS
JUNCTION BOX HOUSING (SECONDARY)INLINE OR COPLANAR TRANSMITTER
CONDUIT CONNECTION(2 PLACES)
NAMEPLATE
FIELD TERMINALS(THIS SIDE)
DIGITAL DISPLAY COVER
TRANSMITTERELECTRONICS(THIS SIDE)
CAPILLARY CONNECTION DIRECT MOUNTCONNECTION
1. 1.2.
SEE 01199-9500 SEAL TYPE 1 DRAWING FOR THE SPECIFIC DIMENSIONS ON THE AVAILABLESEALS. ALL SEALS AVAILABLE ON THE LOW SIDE.
SEE 01199-9500 SEAL TYPE 1 DRAWING FOR THE SPECIFIC DIMENSIONS ON THE AVAILABLESEALS. ALL SEALS AVAILABLE ON THE LOW SIDE.
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
5.17[131] 3.45
[88]
4.20[107]
75D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
PLANTWEB HOUSING(PRIMARY) JUNCTION BOX HOUSING
(SECONDARY)INLINE OR COPLANAR TRANSMITTER
ROSEMOUNT 3051SAM PRESSURE TRANSMITTER COPLANAR FLANGE PROCESS CONNECTION WITH CAPILLARY AND DIRECT MOUNT SEALS
PLANTWEB HOUSINGSHOWN WITH OPTIONAL DIGITAL DISPLAY
(PRIMARY)
TRANSMITTERELECTRONICS(THIS SIDE)CONDUIT CONNECTION
(2 PLACES)
NAMEPLATE
FIELD TERMINALS(THIS SIDE)
DIGITAL DISPLAY COVER
HOUSING ROTATIONSET SCREW
CERTIFICATIONLABEL
AVAILABLE WITH 305 MANIFOLDS. SEE 2 VALVE MANIFOLD TYPE 1 DRAWINGS FOR DIMENSIONS
1. 2.1.
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
5.17[131]
4.51[115]
4.20[107] 3.44
[87]
76D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
PLANTWEB HOUSING(PRIMARY)
JUNCTION BOX HOUSING (SECONDARY)INLINE OR COPLANAR TRANSMITTER
ROSEMOUNT 3051SAM IN-LINE PRESSURE TRANSMITTER IN-LINE MANIFOLD
PLANTWEB HOUSINGSHOWN WITH OPTIONAL DIGITAL DISPLAY
(PRIMARY)
CONDUIT CONNECTION(2 PLACES)
NAMEPLATE
FIELD TERMINALS(THIS SIDE)
DIGITAL DISPLAY COVER
TRANSMITTERELECTRONICS(THIS SIDE)
1. 1.
2.
AVAILABLE WITH 306 MANIFOLDS. SEE MANIFOLD TYPE 1 DRAWINGS FOR DIMENSIONS
FORM REV AA
1 2 3 4 5 6 7 8
A
D
C
B
E
F
9 10 11 12 13 14 15 16
G
K
J
H
L
M
A
D
C
B
E
F
G
K
J
H
L
M MM
DR.
DO NOT SCALE PRINT
TITLE
SIZE
D
DRAWING NO.
APP'D
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES [mm].
CONFIDENTIAL AND PROPRIETARY
INFORMATION IS CONTAINED HEREIN
AND MUST BE HANDLED ACCORDINGLY.
EMERSON
REV
CAD MAINTAINED, (PRO/E)
SCALE
DOC TYPE
3RD ANGLE
PRODUCT CODE SHEET OF
CUSTOMER
P.O. No.
S.O. No.
PROJECT NAME
CUSTOMER DWG NO.
INFORMATION WITHIN THIS
DOCUMENT MAY CHANGE WITHOUT
NOTICE. NOT INTENDED FOR
ENGINEERING USE. REFERENCE
ROSEMOUNT PRODUCT DATA SHEETS
FOR ENGINEERING INFORMATION.
DRAWING NO.
TAG NO.
CAL.
3.25[83]
8.671[220,2]
6.25[159]
4.72[120]
8.09[205]
2.33[59]
4.490[114,0]
77D
03151-70013/8/13PF
3/8/13JLA
PRESSURE TRANSMITTER3051SAM ERS
AA1/2
03151-7001
REMOTE DISPLAY MOUNTING CONFIGURATION (PRIMARY)
3.