root cause examples (i)
TRANSCRIPT
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 1/56
1© 2004 Superfactory™. All Rights Reserved.
Manufacturing
Root Cause AnalysisExample #1
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 2/56
2© 2004 Superfactory™. All Rights Reserved.
Example #1
Identify Problem
Part polarity reversed on circuit board
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 3/56
3© 2004 Superfactory™. All Rights Reserved.
Immediate Action
Additional inspection added after this assembly processstep to check for reversed part defects
Last 10 lots of printed circuit boards were re-inspected to
check for similar errors
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 4/56
4© 2004 Superfactory™. All Rights Reserved.
Root Cause
Part reversed
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 5/56
5© 2004 Superfactory™. All Rights Reserved.
Root Cause
Part reversed
Worker not sure of correct part orientation
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 6/56
6© 2004 Superfactory™. All Rights Reserved.
Part is not marked properly
Root Cause
Part reversed
Worker not sure of correct part orientation
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 7/567© 2004 Superfactory™. All Rights Reserved.
Engineering ordered it that way from vendor
Part is not marked properly
Root Cause
Part reversed
Worker not sure of correct part orientation
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 8/56
8© 2004 Superfactory™. All Rights Reserved.
Process didn’t account for possible
manufacturing issues
Engineering ordered it that way from vendor
Part is not marked properly
Root Cause
Part reversed
Worker not sure of correct part orientation
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 9/56
9© 2004 Superfactory™. All Rights Reserved.
Corrective Action
Permanent – Changed part to one that can only be placed in correct
direction (Mistake proofed). Found other products with similar problemand made same changes.
Preventive - Required that any new parts selected must have
orientation marks on them.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 10/56
10© 2004 Superfactory™. All Rights Reserved.
Root Cause AnalysisExample #2
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 11/56
11© 2004 Superfactory™. All Rights Reserved.
Example #2
Identify Problem
A manager walks past the assembly line and notices a puddle of water on the floor. Knowing that the water is a safety hazard, sheasks the supervisor to have someone get a mop and clean up thepuddle. The manager is proud of herself for “fixing” a potential
safety problem.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 12/56
12© 2004 Superfactory™. All Rights Reserved.
Example #2
But What is the Root Cause?
The supervisor looks for a root cause by asking 'why?’
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 13/56
13© 2004 Superfactory™. All Rights Reserved.
Immediate Action
Knowing that the water is a safety hazard, the manager asks thesupervisor to have someone get a mop and clean up the puddle.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 14/56
14© 2004 Superfactory™. All Rights Reserved.
Root Cause
Puddle of water on the floor
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 15/56
15© 2004 Superfactory™. All Rights Reserved.
Root Cause
Puddle of water on the floor
Leak in overhead pipe
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 16/56
16© 2004 Superfactory™. All Rights Reserved.
Water pressure is set too high
Root Cause
Puddle of water on the floor
Leak in overhead pipe
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 17/56
17© 2004 Superfactory™. All Rights Reserved.
Water pressure valve is faulty
Water pressure is set too high
Root Cause
Puddle of water on the floor
Leak in overhead pipe
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 18/56
18© 2004 Superfactory™. All Rights Reserved.
Valve not in preventative maintenance program
Water pressure valve is faulty
Water pressure is set too high
Root Cause
Puddle of water on the floor
Leak in overhead pipe
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 19/56
19© 2004 Superfactory™. All Rights Reserved.
Corrective Action
Permanent – Water pressure valves placed in preventativemaintenance program.
Preventive - Developed checklist form to ensure new
equipment is reviewed for possible inclusion in preventativemaintenance program.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 20/56
20© 2004 Superfactory™. All Rights Reserved.
Example #3
Root Cause AnalysisExample #3
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 21/56
21© 2004 Superfactory™. All Rights Reserved.
Example #3
Identify Problem
Customers are unhappy because they are being shipped
products that don't meet their specifications.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 22/56
22© 2004 Superfactory™. All Rights Reserved.
Immediate Action
Inspect all finished and in-process product to ensure it meetscustomer specifications.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 23/56
23© 2004 Superfactory™. All Rights Reserved.
Root Cause
Product doesn’t meet specifications
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 24/56
24© 2004 Superfactory™. All Rights Reserved.
Root Cause
Product doesn’t meet specifications
Manufacturing specification is different from
what customer and sales person agreed to
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 25/56
25© 2004 Superfactory™. All Rights Reserved.
Sales person tries to expedite work by calling
head of manufacturing directly
Root Cause
Product doesn’t meet specifications
Manufacturing specification is different from
what customer and sales person agreed to
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 26/56
26© 2004 Superfactory™. All Rights Reserved.
Manufacturing schedule is not available for
sales person to provide realistic delivery date
Sales person tries to expedite work by calling
head of manufacturing directly
Root Cause
Product doesn’t meet specifications
Manufacturing specification is different from
what customer and sales person agreed to
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 27/56
27© 2004 Superfactory™. All Rights Reserved.
Confidence in manufacturing schedule is not
high enough to release/link with order system
Manufacturing schedule is not available for
sales person to provide realistic delivery date
Sales person tries to expedite work by calling
head of manufacturing directly
Root Cause
Product doesn’t meet specifications
Manufacturing specification is different from
what customer and sales person agreed to
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 28/56
28© 2004 Superfactory™. All Rights Reserved.
Root Cause
Confidence in manufacturing schedule is not
high enough to release/link with order system
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 29/56
29© 2004 Superfactory™. All Rights Reserved.
Root Cause
Confidence in manufacturing schedule is not
high enough to release/link with order system
Parts sometimes not available thereby
creating schedule changes
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 30/56
30© 2004 Superfactory™. All Rights Reserved.
Expediting and priority changes consume
parts not planned for
Root Cause
Confidence in manufacturing schedule is not
high enough to release/link with order system
Parts sometimes not available thereby
creating schedule changes
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 31/56
31© 2004 Superfactory™. All Rights Reserved.
Manufacturing schedule does not reflect
realistic assembly and test time
Expediting and priority changes consume
parts not planned for
Root Cause
Confidence in manufacturing schedule is not
high enough to release/link with order system
Parts sometimes not available thereby
creating schedule changes
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 32/56
32© 2004 Superfactory™. All Rights Reserved.
No ongoing review of manufacturing standards
Manufacturing schedule does not reflect
realistic assembly and test time
Expediting and priority changes consume
parts not planned for
Root Cause
Confidence in manufacturing schedule is not
high enough to release/link with order system
Parts sometimes not available thereby
creating schedule changes
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 33/56
33© 2004 Superfactory™. All Rights Reserved.
Corrective Action
Permanent – Manufacturing standards reviewed andupdated.
Preventive - Regular ongoing review of actuals vs
standards is implemented.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 34/56
34© 2004 Superfactory™. All Rights Reserved.
Root Cause AnalysisExample #4
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 35/56
35© 2004 Superfactory™. All Rights Reserved.
Example #4
Identify Problem
Department didn’t complete their project on time
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 36/56
36© 2004 Superfactory™. All Rights Reserved.
Immediate Action
Additional resources applied to help get the project teamback on schedule
No new projects started until Root Cause Analysiscompleted
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 37/56
37© 2004 Superfactory™. All Rights Reserved.
Root Cause
Didn’t complete project on time
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 38/56
38© 2004 Superfactory™. All Rights Reserved.
Cause and Effect
Didn’t complete
project on time
EquipmentMaterials
PersonnelProceduresLack of worker
knowledge
Poor project
mgmt skills
Poor project plan
Inadequate
computer
programs
Inadequate
computer system
Poor
documentation
Lack of resources
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 39/56
39© 2004 Superfactory™. All Rights Reserved.
Cause and Effect
Didn’t complete
project on time
EquipmentMaterials
PersonnelProceduresLack of worker
knowledge
Poor project
mgmt skills
Poor project plan
Inadequate
computer
programs
Inadequate
computer system
Poor
documentation
Lack of resources
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 40/56
40© 2004 Superfactory™. All Rights Reserved.
Root Cause
Didn’t complete project on time
Resources unavailable when needed
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 41/56
41© 2004 Superfactory™. All Rights Reserved.
Took too long to hire Project Manager
Root Cause
Didn’t complete project on time
Resources unavailable when needed
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 42/56
42© 2004 Superfactory™. All Rights Reserved.
Lack of specifics given to
Human Resources Dept
Took too long to hire Project Manager
Root Cause
Didn’t complete project on time
Resources unavailable when needed
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 43/56
43© 2004 Superfactory™. All Rights Reserved.
No formal process for submitting job opening
Lack of specifics given to
Human Resources Dept
Took too long to hire Project Manager
Root Cause
Didn’t complete project on time
Resources unavailable when needed
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 44/56
44© 2004 Superfactory™. All Rights Reserved.
Corrective Action
Permanent – Hired another worker to meet needs of nextproject team
Preventive - Developed checklist form with HR forsubmitting job openings in the future
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 45/56
45© 2004 Superfactory™. All Rights Reserved.
Example #5
Root Cause AnalysisExample #5
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 46/56
46© 2004 Superfactory™. All Rights Reserved.
Example #5
Identify Problem
High pyrogen count on finished medical catheter product using
molded components.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 47/56
47© 2004 Superfactory™. All Rights Reserved.
Immediate Action
Immediate Action (and panic!)
Quarantine all finished and in-process product
(over $2 million worth!)
Analyze location of pyrogen to find common denominator
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 48/56
48© 2004 Superfactory™. All Rights Reserved.
Panic-Driven Action
Panic-driven Immediate Reaction(without root cause analysis)
Pyrogen traced to molding cooling water leak Holy cow!… cooling water system hasn’t been cleaned in 15 years! Shut down 24/7 molding operation for 2 days to clean cooling water system Implement system for weekly analysis of cooling water for pyrogens Threaten to fire anyone who doesn’t report a cooling water leak
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 49/56
49© 2004 Superfactory™. All Rights Reserved.
Panic-Driven Action - Results
Results of Panic-driven Immediate Reaction(without root cause analysis)
Day 1 after cooling water system cleaning: water tests clean of pyrogens
Day 2: cooling water is saturated with pyrogens. Uh oh.
All operators and technicians reporting “possible water leaks” onall presses, all molds, all shifts… “just in case”.
Molding operation shuts down. Operations manager nearly fired.
“Help” flying in from corporate offices and other molding plants. Hourly conference calls to give status updates to executives.
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 50/56
50© 2004 Superfactory™. All Rights Reserved.
Logic Returns
There must be a better way! How about trying something called “Root Cause Analysis”?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 51/56
51© 2004 Superfactory™. All Rights Reserved.
Root Cause
Pyrogens on molded components
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 52/56
52© 2004 Superfactory™. All Rights Reserved.
Root Cause
Pyrogens on molded components
Parts released from molding even though they
had been sprayed with leaking cooling water
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 53/56
53© 2004 Superfactory™. All Rights Reserved.
Disposition of contaminated parts procedure
does not discuss water
Root Cause
Pyrogens on molded components
Parts released from molding even though they
had been sprayed with leaking cooling water
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 54/56
54© 2004 Superfactory™. All Rights Reserved.
Oil, grease, dust, human contact believed to
be primary sources of contamination
Disposition of contaminated parts procedure
does not discuss water
Root Cause
Pyrogens on molded components
Parts released from molding even though they
had been sprayed with leaking cooling water
Why?
7/30/2019 Root Cause Examples (I)
http://slidepdf.com/reader/full/root-cause-examples-i 55/56
55© 2004 Superfactory™. All Rights Reserved.
No formal evaluation of contamination sources,
types, severity, and disposition action.
Oil, grease, dust, human contact believed to
be primary sources of contamination
Disposition of contaminated parts procedure
does not discuss water
Root Cause
Pyrogens on molded components
Parts released from molding even though they
had been sprayed with leaking cooling water