W E T H E R H O L T A N D A S S O C I A T E S , I N C . 2633A Parkmont Lane Southwest, Suite A-1 y 1001 Cooper Point Road Southwest, #140 – PMB 185 Olympia, Washington 98502 Phone: 360-786-1660 y Fax: 360-786-1696 Roof Evaluation SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684 Olympia, WA 98507 Attn: Stephen Masini June 26, 2008 Project: 20-990601C3

Upload: others

Post on 25-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

W E T H E R H O L T A N D A S S O C I A T E S , I N C .

2633A Parkmont Lane Southwest, Suite A-1 1001 Cooper Point Road Southwest, #140 – PMB 185 Olympia, Washington 98502

Phone: 360-786-1660 Fax: 360-786-1696

Roof Evaluation

SITE VISIT – June 24, 2008

Insurance Building Capitol Campus

Olympia, Washington

for

Stephen A. Masini. AIA P.O. Box 2684

Olympia, WA 98507

Attn: Stephen Masini

June 26, 2008

Project: 20-990601C3

Page 2: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 2 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

2633A Parkmont Lane Southwest, Suite A-1 1001 Cooper Point Road Southwest, #140 – PMB 185 Olympia, Washington 98502

Phone: 360-786-1660 Fax: 360-786-1696

June 26, 2008 Stephen A. Masini, AIA P.O. Box 2684 Phone: (360) 951-1697 Olympia, Washington 98507 Fax: n/a Attn: Stephen Masini Email: [email protected] Ref: Roof Evaluation Insurance Building

Capitol Campus Olympia, Washington

Greetings, At the request of Stephen Masini this writer performed a visual survey of the roof and building exterior areas covering the Insurance Building on June 24, 2008 to evaluate the condition of the roof and building exterior.

Enclosed are photographs taken during our site visit for your review.

We trust the above discussion has been of assistance. If you have any questions, or if we may be of further service, please do not hesitate to call. Respectfully,

William Cypher, RRC, FRCI Senior Field Engineer Principal Enclosures: Photographs Please note that this inspection is provided at the request of Stephen A. Masini, AIA. No liability, warranty of merchantability, or guarantee of roof service life is accepted or implied. Wetherholt and Associates, Inc. is a neutral consulting engineering/roofing consulting firm specializing in resolving building and roof related issues.

Page 3: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 3 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 1: Looking west up the north rake of the east slope.

Photograph 2: Looking directly up the east slope at panel coating.

Photograph 3: Looking up at the valley line along the northern most radius dormer of the east slope.

Page 4: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 4 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 4: North central raised panel area north end east slope.

Photograph 5: Showing the radius dormer glass front of the dormer.

Photograph 6: Streaking on the glazing in front of one of the dormers. Contractor stated it was there before but they will clean the windows.

Page 5: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 5 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 7: Fourth dormer from the north end up-slope transition to the raised area open lap and flashing detail under overhang.

Photograph 8: Rapid light sensor with some dog ears on flashing detail.

Photograph 9: Some light coated areas at upslope panel to ridge termination. Requires additional brush coating.

Page 6: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 6 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 10: Some light coated areas at upslope panel to ridge termination. Requires additional brush coating.

Photograph 11: Un-bonded flashing cut open reseal with coating.

Photograph 12: Double stand pipe south quadrant east slope, upslope north side of pipe penetration lacking coating.

Page 7: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 7 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 13: Coating tracks from a seagull jumping into the wet coating and walking up to the top of the parapet. Contractor believes he can attempt to try and clean with warm soap and water.

Photograph 14: North side of the first dormer south end west slope re-coat under seam adjacent valley.

Photograph 15: Simple open lap in fabric membrane upper portion same valley.

Page 8: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 8 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 16: West slope down slope with a hatch raised area north side of dormer. Upslope base flashing three blisters along transition to cant; cut blisters, re-seal and re-coat.

Photograph 17: West slope down slope with a hatch raised area north side of dormer. Upslope base flashing three blisters along transition to cant; cut blisters, re-seal and re-coat.

Photograph 18: Flag pole cradle along the ridge line north end fabric loose re-seal and re-coat. Same thing at adjacent lap seam and fabric on the east side north end.

Page 9: Roof Evaluation SITE VISIT – June 24, 2008 Insurance ...SITE VISIT – June 24, 2008 Insurance Building Capitol Campus Olympia, Washington for Stephen A. Masini. AIA P.O. Box 2684

Site Visit – 6/24/2008 Page 9 Insurance Building June 26, 2008 Stephen Masini 20-990601C3

Photograph 19: North end west slope at raised short platform area. Couple of open laps and fabric; coat and re-seal.