rites ltd. civil work (based on ... 4 electrical work (based on market rate) total amount...

110
INDIAN COUNCIL OF AGRICULTURAL RESEARCH, NEW DELHI TENDER AND CONTRACT DOCUMENT Name of Work: Construction of Auditorium at NASC Complex, Pusa Road, New Delhi TENDER NO.: RITES/CP/ICAR/AUDI/2011 PART 2: FINANCIAL BID JUNE 2011 RITES Ltd. (A Govt. of India Enterprise) Plot No.144, Sector44, Gurgaon (Haryana) 122003

Upload: nguyenthu

Post on 08-Mar-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

INDIAN COUNCIL OF AGRICULTURAL RESEARCH, NEW DELHI

TENDER AND CONTRACT DOCUMENT

Name of Work: Construction of Auditorium at NASC Complex, Pusa Road, New Delhi

TENDER NO.: RITES/CP/ICAR/AUDI/2011

PART 2: FINANCIAL BID

JUNE 2011

 

 

 

 

RITES Ltd. (A Govt. of India Enterprise)  Plot No.‐144, Sector‐44,  

Gurgaon (Haryana) ‐ 122003   

Page 2: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

S.NO. Particulars Estimated Cost (in Rupes)

Quoted %age above/below (in Figures &

Words)

Quoted Amount (inRupes)

1 Civil work (Based on DSR 2007)

2 Electrical work (Based on DSR2007)

3 Civil work (Based on MarketRate)

4 Electrical work (Based on MarketRate)

Total AmountUn-conditional rebate if any

Amount after rebate in figure

Amount after rebate in Words

Project Name: Construction of Auditorium/Convention Centre at NASC Complex, PUSA, New Delhi.

FINAL ABSTRACT OF COST

Tender No. RITES/CP/ICAR/AUDI/2011

Percentage and Amount to be quoted by the contractor

(Signature of Contractor with Seal)

Page 3: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

S.No. Description of Work DSR Amount (in Rs.) Remarks

A Earthwork 9002619.40

B Concrete 234414451.15

C Masonary Works 9288358.41

D Wood, Iron and Steel Works 7096289.05

E Joinery works 121762.40

F Flooring Works 10688110.95

G Internal & External Finshes 10480714.72

H Roofing Works 1416485.00

I Water proofing Works 6702770.10

J Road Works 2039791.55

K Stone works 15582688.52

L Plumbing And Sanitation Works 1393953.15

308,227,994.40 Total Amount

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI

Abstract of Cost for Civil Works

PART-I Scheduled Items based on DSR 2007 (Reprint DSR 2010)

Page 4: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

A EARTHWORK

1 Earth work in excavation by mechanical means(Hydraulic excavator )manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, leadupto 50m and lift upto 1.5m, disposed earth to belevelled and neatly dressed.All kinds of soil

1.1 DSR 2.6.1 up to 1.5 m below G.L. cum 31725.00 101.85 3231191.25

2 DSR 2.26.1 Extra for every aditional lift of 1.5m cum 33018.00 18.90 624040.20

3 Earth work in excavation by mechanical means(Hydraulic excavator )/manual means in foundationtrenches or drains (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out theexcavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m.

3.1 DSR 2.8.1 All kinds of soil.cum 650.00 103.40 67210.00

4 DSR 2.25 Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundation etc, in layers of notexceeding 20 cm in depth, consolidating each depositedlayer by rammiing and watering lead upto 50 m and liftupto 1.5 m.

cum 5665.00 45.70 258890.50

5 DSR 2.27 Supplying and filling in plinth with Jamuna sand underfloors including, watering, ramming consolidating anddressing complete.

cum 972.00 301.50 293058.00

6 Disposal of excavated excess earth away from the siteincluding conveyance of materials up to an average leadof 1KM away from the site, and correspondiong requiredlift, loading, unloading etc complete as directed by theEngineer-in-charge. (The quantity is net quantity ofcapacity of truck after deduction of 20% forlooseness)(considering the maximum disposal locationat 5 KM distance)

6.1 DSR 1.12(8 )

By mechanical transport including loading, unloadingand stacking. ( Lead upto 5KM away from the site) cum 37000.00 76.48 2829760.00

7 DSR 1.1.2 Extra for transporting earth beyond 5km upto 10 kmincluding cost of loading,unloading as per the direction ofengineer incharge(The quantity is net quantity of cap. Oftruck after deduction of 0% of voids

7.1 By mechanical transport cum 37000.00 5.84 216080.00

8 Earth work in excavation/ by mechanical means(Hydraulic Excavator)/ manual means over areas(exceeding 30 cm in depth, 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, leadupto 50 m and lift upto 1.5 m, disposed earth to belevelled and neatly dressed.

8.1 DSR 2.7.1 Ordinary rockcum 25.00 152.60 3815.00

9 DSR 2.26 Extra for every additional lift of 1.5 m or part thereof in.

9.1 DSR 2.26.2 Ordinary or Hard rockcum 50.00 33.85 1692.50

10 Earth work in excavation/ by mechanical means(Hydraulic Excavator)/ manual means over areas(exceeding 30 cm in depth, 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, leadupto 50 m and lift upto 1.5 m, disposed earth to belevelled and neatly dressed.

10.1 DSR 2.7.3 Hard rock (blasting prohibited) cum 25.00 325.25 8131.25

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI

BILL OF QUANTITYPART-I Scheduled Items based on DSR 2007 (Reprint DSR 2010)

Page 5: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

11 Disposal of excavated excess rock away from the siteexcluding conveyance of materials upto an average leadof 1KM away from the site, and correspondiong requiredlift, loading, unloading etc complete as directed by theEngineer-in-charge. (The quantity is net quantity ofcapacity of truck after deduction of 40% forlooseness)(considering the maximum disposal locationat 5KM distance)

11.1 DSR 1.1.4(4)

By mechanical transport including loading, unloadingand stacking. ( Lead upto 5KM away from the site) cum 120.00 79.07 9488.40

12 DSR 1.1.4 Extra for transporting rock beyond 5km upto 10 kmincluding cost of loading,unloading as per the direction ofengineer incharge(The quantity is net quantity of cap. Oftruck after deduction of 40% for looseness)

cum 120.00 90.05 10806.00

13 2.034 Supplying chemical emulsion in sealed containersincluding delivery as specified.

13.1 2.34.01 Chlorpyriphos/Lindane emulsifiable concentrate of 20%litre 174.30

4000697200.00

02.035 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excludingthe cost of chemical emulsion)

14 2.35.1 Along external wall where the apron is not providedusing chemical emulsion @ 7.5 litres/ sqm of the verticalsurface of the substructure to a depth of 300 mmincluding excavation channel along the wall and roddingetc complete:

14.1 2.35.1.1 With chlorpyriphos/Lindane E.C. 20% with 1%concentration.

One Metre

6.75 450030375.00

14.2 2.35.1.2 Along the external wall below concrete or masonry apronusing chemical emulsion @ 2.25 litres per linear metreincluding drilling and plugging holes etc.

14.2 (a)

2.35.1.2.1 With chlorpyriphos/Lindane E.C. 20% with 1%concentration.

One Metre

10.45 300031350.00

14.3 2.35.1.3 Treatment of soil under existing floors using chemicalemulsion @ one litre per hole, 300 mm apart includingdrilling 12 mm diameter holes and plugging with cementmortar 1:2 ( 1 cement : 2 coarse sand ) to match theexisting floor.

14.3(a) 2.35.1.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1%concentration.

One Square

48.70 3000146100.00

14.4 2.35.5 Treatment at points of contact of wood work by chemicalemulsion chlorpyriphos. (in oil or kerosene basedsolution) @ 0.5 litres per hole by drilling 6 mm dia holesat downward angle of 45 degree at 150 mm centre tocentre and sealing the same.

One Metre

79.80 500

39900.00

15 Supplying and stacking at site

15.1 DSR 16.3.8 Red Bajricum 752.00 654.15 491920.80

16 DSR 16.11 Dry stone pitching 22.5 cm thick including supply ofstones and preparing surface complete. sqm 55.00 211.10 11610.50

Total C/o to Summary : Rs. 9002619.40

B CONCRETE & RCC WORKS1 Providing and laying in position cement concrete of

following specified grade excluding the cost of centringand strutting - All work upto plinth level.

1.1 DSR 4.1.8 1:4:8 (1 cement: 4 coarse sand: 8 graded stoneaggregate 40 mm nominal size) cum 490.00 2449.00 1200010.00

1.2 DSR 4.1.6 1:3:6 (1 Cement : 3 coarse sand : 6 graded stoneaggregate 40 mm nominal size). cum 780.00 2713.05 2116179.00

Page 6: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

2 DSR 5.33 Providing and laying in position machine batched,machine mixed and machine vibrated design mix cementconcrete of specified grade for reinforced cementconcrete work including pumping of concrete to site oflaying but excluding the cost of centering,shuttering,finishing and reinforcement. including Admixtures inrecommended proportions as per IS 9103 to accelerate,retard setting of concrete, improve workability withoutimpairing strength and durability as per direction ofEngineer-in-charge. M-25 grade reinforced cementconcrete by using 380kg. of cement per cum of concrete.All work upto plinth level.

cum 7520.00 3983.75 29957800.00

3 Add or deduct for providing leaner or richer mixesrespectively at all floor levels.

3.1 DSR 5.34.1 Providing M 30 Grade concrete by using 400 Kg ofcement per CUM of concrete instead of M25 grade BMC/ RMC

cum 18159.00 109.10 1981146.90

4 DSR 5.35 Deduct for using less cement than the quantity asprovided in the item of batch mix concrete/RMC asarrived as per mix design.

Quintal 3500.00 528.15 1848525.00

5 DSR 5.33 A Providing and laying in position machine batched,machine mixed and machine vibrated design mix cementconcrete of specified grade for reinforced cementconcrete work including pumping of concrete to site oflaying but excluding the cost of centering, shuttering,finishing and reinforcement. including Admixtures inrecommended proportions as per IS 9103 to accelerate,retard setting of concrete, improve workability withoutimpairing strength and durability as per direction ofEngineer-in-charge. M-25 grade reinforced cementconcrete by using 380kg. of cement per cum of concrete.All work above plinth level up to floor V level.

cum 10692.00 3983.75 42594255.00

6 DSR 5.13 Providing, hoisting and fixing upto floor five level precastreinforced cement concrete in small lintels not exceeding1.5m clear span upto floor five level including the cost ofrequired centring, shuttering and finishing smooth with6 mm thick cement plaster 1:3 (1 cement : 3 fine sand)on exposed surfaces but excluding the cost ofreinforcement with 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20mm nominal size).

cum 50.00 6002.80 300140.00

7 DSR 4.11 Providing and laying damp-proof course 50mm thick withcement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20mm nominal size).

Sqm 100.00 178.05 17805.00

8 DSR 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V levelfor each four floors or part thereof. cum 10.00 92.90 929.00

9 DSR 4.13 Applying a coat of residual petroleum bitumen ofpenetration 80/100 of approved quality using 1.7kg persquare metre on damp proof course after cleaning thesurface with brushes and finally with a piece of clothlightly soaked in kerosene oil.

sqm 100.00 58.60 5860.00

10 DSR 4.17 Making plinth protection 50mm thick of cement concrete1:3:6 (1cement :3 coarse sand : 6graded stoneaggregate 20mm nominalsize) over 75mm bed by drybrick ballast 40mm nominal size well rammed andconsolidated and grouted with fine sand includingfinishing the top smooth

Sqm 500.00 222.65 111325.00

11 Centering and shuttering including strutting, proppingetc. and removal of formwork for :

11.1 DSR 4.3.1 Foundations, footings, bases of columns sqm 7.00 119.25 834.75

11.2 DSR 5.9.1 Foundations, footings, bases of columns etc. for massconcrete. sqm 5216.00 119.25 622008.00

11.3 DSR 5.9.2 Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc. sqm 4380.00 180.40 790152.00

11.4 DSR 5.9.3 Suspended floors, roofs, landings, balconies and accessplatform. sqm 19040.00 187.35 3567144.00

11.5 DSR 5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers. sqm 24765.00 162.65 4028027.25

Page 7: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

11.6 DSR 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 6107.00 238.40 1455908.80

11.7 DSR 5.9.7 Stairs, (excluding landings) except spiral-staircases.sqm 4112.00 204.00 838848.00

11.8 DSR 5.9.13 Vertical and horizontal fins individually or forming boxlouvers band, facias and eaves boards. sqm 100.00 285.55 28555.00

11.9 DSR 5.9.15 Small lintels not exceeding 1.5m clear span, mouldingas in cornices, window sills, string courses,bands,copings, bed plates, anchor blocks and the like. sqm 6610.00 119.25 788242.50

11.10 DSR 5.9.14 Extra for shuttering in circular work ( 20% of respectivecentering and shuttering items) for Roof beams Sqm 19040.00 0.20 3808.00

11.11 DSR 5.9.19 Weather shade, Chajjas, corbels etc., including edgesSqm 115.00 258.60 29739.00

11.12 DSR 5.9.5 Lintels, beams, plinth beams, girders, bressumers andcantilevers. sqm 436.00 162.65 70915.40

12 Extra for additional height in centering, shuttering whereever required with adequate bracing, propping etc.including cost of de-shuttering and decentering at alllevels, over a height of 3.5m, for every additional heightof 1 metre or part thereof (Plan area to be measured)

12.1 DSR 5.11.1 Suspended floors, roofs, landing, beams and balconies(Plan area to be measured). sqm 123276.00 70.20 8653975.20

Steel Reinforcement13 DSR 5.22.6 Reinforcement for R.C.C. work including straightening,

cutting, bending, placing in position and binding allcomplete. Upto plinth level.

13.1 Thermo-Mechanically Treated bars. Fe500 Kg 1022768.00 42.70 43672193.6014 DSR

5.22.A6Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding allcomplete. Above plinth level.

14.1 Thermo-Mechanically Treated bars. Fe500 Kg. 2100765.00 42.70 89702665.5015 DSR 22.4 Providing and Placing in position suitable PVC water

stops confirming to IS 12200 for Construction /Expansion joints between two RCC members and fixedto the reinforcement with binding wire before concreteetc

15.1 DSR 22.4.1 Serrated with central bulb (22.5mm wide , 8-11 mm th) metre 71.00 386.75 27459.25Total carried over to summary : Rs. 234414451.15

C MASONRY WORKS

1DSR 6.1.2

Brick work with F.P.S. bricks of class designation 75 infoundation and plinth in: Cement mortar 1:6 (1 cement :6 coarse sand)

cum 368.00 2121.75 780804.00

2 Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level up to floor V level in allshapes and sizes in :

2.1 DSR 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 3398.00 2430.25 8257989.50

3 DSR 6.12.2 Half brick masonry with F.P.S. brick of class designation75 in foundations and plinth in : cement mortar 1:4 (1cement : 4 coarse sand)

Sqm 28.30 270.35 7650.91

4 DSR 6.13.2 Half brick masonry with F.P.S. bricks of classdesignation 75 in superstructure above plinth level uptofloor V level. cement mortar 1:4 (1 cement : 4 coarsesand)

sqm 690.00 302.80 208932.00

5 DSR 6.15 Extra for providing and placing in position 2 Nos. 6mmdia. M.S. bars at every third course of half brick masonry(with F.P.S. bricks).

Sqm 690.00 47.80 32982.00

Total C/o to Summary : Rs. 9288358.41

Page 8: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

D WOOD, Structural STEEL WORKS

1 DSR 10.2 Structural steel work riveted, bolted or welded in built upsections,trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete:

Kg 146575.00 46.35 6793751.25

2 Supplying and fixing rolling shutters of approved make,made of required size M.S. laths interlocked togetherthrough their entire length and jointed together at the endby end locks mounted on specially designed pipe shaftwith brackets, side guides and arrangements for insideand outside locking with push and pull operationcomplete including the cost of providing and fixingnecessary 27.5cm long wire springs grade No.2 andM.S. top cover of required thickness for rolling shutters.

2.1 DSR 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 35.00 1208.45 42295.75

3 DSR 10.7 Providing and fixing ball bearing for rolling shutters. each 10.00 356.50 3565.004 DSR 9.48.2 Providing and fixing M.S. grills of required pattern in

frames of windows etc. with M.S. flats, square or roundbars etc. all complete.

Fixed to openings /wooden frames with rawl plugsscrews etc. kg 270.00 64.40 17388.00

5 Providing and fixing 1mm thick M.S. sheet door withframe of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approvedsteel primer.

5.1 DSR 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces. sqm 7.00 1695.40 11867.806 Providing and fixing hand rail of approved size by

welding etc. to steel ladder railing, balcony railing andstaircase railing including applying a priming coat ofapproved steel primer.

6.1 DSR 10.26.2

E.R.W. tubes kg 2765.00 82.25 227421.25

Total C/o to Summary : Rs. 7096289.05

E JOINERY WORKS

1 DSR 14.28.1

Providing and fixing curtain rods of 1.25mm thick brassplates with two brass brackets fixed with brass screwsand wooden plugs etc. wherever necessary complete.

20 mm diameter. metre 227.00 116.20 26377.402 DSR 21.4.2 Providing and fixing double action hydraulic floor spring

of approved brand and manufacture IS : 6315 marked,for doors including cost of cutting floors as required,embedding in floors and cover plates with brass pivotand single piece M.S. sheet outer box with slide plateetc.complete as per the direction of Engineer-in-charge.

With brass cover plate each 50.00 1907.70 95385.00Total C/o to Summary : Rs. 121762.40

Page 9: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

F FLOORING WORKS 1 DSR 11.4 52 mm thick cement concrete flooring with concrete

hardener topping under layer 40 mm thick cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1cement hardener mix : 2 graded stone aggregate 6 mmnominal size) by volume .hardening compound is mixed@ 2 litre per 50kg of cement or as per manufacturersspecifications. This includes cost of cement slurry, butexcluding the cost of nosing of steps etc. complete. ( UTILITY BUILDING )

sqm 405.00 286.50 116032.50

2 DSR 11.41.2

Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) withwater absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laidon 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand) including grouting the joints with white cement andmatching pigments etc., complete.

2.1 Size of Tile 60x60 cm sqm 1650.00 1031.85 1702552.503 DSR

11.26.1Kota stone slab flooring over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixedwith pigment to match the shade of the slab includingrubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) :

sqm 592.00 694.4 411084.80

3.1 25 mm thick.

4 DSR 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting,dado and pillars laid on 12 mm (average) thick cementmortar 1:3 (1 cement 3 coarse sand) and jointed withgrey cement slurry mixed with pigment to match theshade of the slabs, including rubbing and polishingcomplete.

sqm 392.00 676.75 265286.00

5 DSR 11.31 Extra for pre finished nosing in treads of steps of Kotastone/ Sand Stone Slab metre 1264.00 26.40 33369.60

Page 10: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

6 DSR 11.5 62 mm thick cement concrete flooring with concretehardener topping under layer 50 mm thick cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1cement hardener mix : 2 graded stone aggregate 6mmnominal size) by volume. Hardening compound is mixed@ 2 litre per 50kg of cement or as per manufacturesspecifications. This includes cost of cement slurry, butexcluding the cost of nosing of steps etc. complete.

sqm 7731.00 318.65 2463483.15

7 DSR 11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate) finished with a floatingcoat of neat cement including cement slurry, butexcluding the cost of nosing of steps etc. complete.

7.1 40mm thick with 20 mm nominal size stone aggregate sqm 82.00 192.95 15821.90

8 DSR 8.7.2 Providing and fixing cramps of required size & shape inRCC/ CC backing with cement mortar 1:2 ( 1 cement :2coarse sand) including drilling necessary hole in stonesand embedding the cramp in the hole (fasstner to bepaid separetely)

8.1 Stainless Steel Cramps kg 1153.00 529.5 610513.509 DSR 8.8.1.2 Providing and fixing expansion hold fastners on CC/

RCC surface backing including drilling necessary holesand the cost of bolt etc. complete. Wedges expansiontype

9.1 Fastener with threaded dia 10 mm. each 6000.00 18.95 113700.00

10 DSR 8.1.1.2 Marble work gang saw cut (polished and machine cut) ofthickness18mm for wall lining (veneer work) in cementmortar 1:3 (1 cement : 3coarse sand) including pointingwith white cement mortar 1:2 (1 white cement : 2 marbledust) with an admixture of pigment to match the marbleshade: (To be secured to the backing by means ofcramps, which shall be paid for separately).

Raj Nagar Plain white marble/ Udaipur green marble/Zebra black marble.

10.1 Area of slab over 0.50 sqm sqm 3000.00 1562.5 4687500.00

11 8.2 Providing and fixing 18 mm thick gang saw cut mirrorpolished premoulded and prepolished ), machine cut forkitchen platforms, vanity counters facias and similarlocations of required size of approved shade, colour andtexture laid over 20 mm thick base cement mortar 1:4 (1cement : 4 coarse sand )with joints treated with whitecement, mixed with matching pigment, epoxy touch ups,including rubbing, curing moulding and polishing toedge to give high gloss finish etc., complete at all levels.

Granite of any colour and shade

11.1 8.2.2.1 Area of slab upto 0.5 sqm sqm 30 2480.20 74406.00

11.2 DSR 8.22.2 Area of slab over 0.50 sqm. sqm 50 2575.1 128755.00

12 8.3 Extra for edge moulding to 18mm thick marble stonecounters, Vanities etc., including machine polishing toedge to give high gloss finish etc., complete as perdesign approved by Engineer-in-charge.

12.1 8.3.2 Granite work metre 225 97.60 21960.00

13 8.4 Extra for fixing marble / granite stone over and abovecorresponding basic item, in facia and drops of widthupto 150mm with epoxy resin based adhesive includingcleaning etc., complete.

metre 225 106.80 24030.00

14 8.5 Extra for providing opening of required size & shape forwash basins / kitchen sink in kitchen platform, vanitycounters and similar location in marble / granite / stonework including necessary holes for pillar taps etc.,including rubbing and polishing of cut edges etc.,complete.

each 80 151.00 12080.00

Page 11: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

15 8.6 Mirror polishing on marble work / granite work / stonework where ever rquired to give high gloss finishcomplete.

sqm 80 94.20 7536.00

Total C/o to Summary : Rs. 10688110.95G Internal and External Finishes

1 DSR 13.2.1 15 mm cement plaster on the rough side of single or halfbrick wall of mix

1.1 1:4 (1 cement:4 fine sand) sqm 16060.67 90.35 1451081.53

2 DSR 13.22 Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3 m orpart thereof.

sqm 5400.00 16.8 90720.00

3 DSR 13.1.1 12 mm cement plaster of mix :1:4 (1 cement: 4 finesand)

sqm 20560.00 77.55 1594428.00

4 DSR 13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall.

sqm 19150.00 128.5 2460775.00

5 DSR 13.21 Extra for providing and mixing water proofingmaterial incement plaster work in proportion recommended by themanufacturers.

Per Bag of 50kg of cement used in the mix

3500.00 28.85 100975.00

6 DSR 13.16.1

6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)sqm 1879.00 62.15 116779.85

7 DSR 13.37.1

White washing with lime to give an even shade

7.1 New work (three or more coats) Sqm 14809.00 6.75 99960.75

8 DSR 13.41.1

Distempering with oil bound washable distemper ofapproved brand and manufacture to give an even shade:New work (two or more coats) over and including primingcoat with cement primer.

sqm 55770.67 41.55 2317271.34

9 DSR 13.47.1

Finishing walls with Premium Acrylic Smooth exteriorpaint with Silicone additives of required shade

9.1 New work (Two or more coats applied @ 1.43 ltr/ 10sqm. over and including base coat of water proofingcement paint applied @ 2.20 kg/ 10 sqm).

sqm 19150.00 60.1 1150915.00

10 DSR 13.62.10

Painting with synthetic enamel paint of approved brandand manufacture of required colour to give an evenshade:

10.1 Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacture.

sqm 20560.00 51.3 1054728.00

11 Finishing walls with textured exterior paint of requiredshade :

11.1 DSR 13.45.1

New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including base coat of water proofing cementpaint applied @ 2.20kg/10 sqm.

sqm 338.0096.25

32532.50

12 Painting with synthetic enamel paint of approved brandand manufacture of required colour to give an evenshade:

Page 12: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

12.1 DSR 13.62.1

Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brandand manufacture

sqm 175.0051.3

8977.50

13 DSR 13.21 Extra for providing and mixing water proofing material incement plaster work in proportion recommended by themanufacturers.

Per bag of 50kg.

of cement used in

55.00

28.55

1570.25

Total C/o to Summary : Rs. 10480714.72

H ROOFING WORKS

1 DSR 12.50 Providing and fixing precoated galvanised iron profilesheets (size, shape and pitch of corrugation as approvedby Engineer-in-charge) 0.50 mm + 5% total coatedthickness (TCT), Zinc coating 120gsm as per IS: 277 in240mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 micronsminimum to avoid scratches while transportation andshould be supplied in single length upto 12 metre or asdesired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x55mm) with EPDM seal or with polymer coated J or Lhooks, bolts and nuts 8mm diameterwith bitumen andG.I. limpet washers or with G.I. limpet washers filled withwhite lead complete upto any pitch in horizontal/ verticalor curved surfaces excluding the cost of purlins, raftersand trusses and including cutting to size and shapewherever required.

sqm 2820.00 440.65 1242633.00

2 Providing and fixing precoated galvanised steel sheetroofing accessories 0.50 mm + 5% total coatedthickness (TCT), Zinc coating 120gsm as per IS: 277 in240mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws or with polymercoated J or L hooks, bolts and nuts and or G.I. seambolts and nuts, G.I. plain and bitumen washers complete

2.1 DSR 12 51 1

Ridges plain (500 - 600mm). metre 56.00 458.15 25656.402.2 DSR

12.51.6Gutter .(600 mm over all girth).

metre 120.00 547.8 65736.00

2.3 DSR 12.51.2

Flashings / Aprons ( Up to 600 mm )metre 184.00 448.15 82459.60

Total C/o to Summary : Rs. 1416485.00

Page 13: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

I WATER PROOFING WORKSWater proofing for basement

1 DSR 22.1 Providing and laying integral cement based treatment forwater proofing on horizontal surface at all depth belowground level for under ground structures as directed byEngineer-in-Charge and consisting of : i) Ist layer of22mm to 25mm thick approved and specified roughstone slab over a 25mm thick base of cement mortar 1:3(1 cement : 3 coarse sand) mixed with water proofingcompound conforming to IS:2645 in the recommendedproportion over the leveling course (leveling course to bepaid separately). Joints sealed and grouted with cementslurry mixed with water proofing compound. ii) 2nd layerof 25mm thick cement mortar 1:3 (1 cement: 3 coarsesand) mixed with water proofing compound inrecommended proportions. iii) Finishing top with stoneaggregate of 10mm to 12mm nominal size spreading @8 cudm/sqm thoroughly embedded in the 2nd layer.

1.1 DSR 22.1.1 Using rough kota stone.Sqm 5593.00 545.1 3048744.30

2 DSR 22.2 Providing and laying integral cement based treatment forwater proofing on the vertical surface by fixing specifiedstone slab 22 mm to 25mm thick with cement slurrymixed with water proofing compound conforming toIS:2645 in recommended proportions with a gap of20mm (minimum) between stone slabs and the receivingsurfaces and filling the gaps with neat cement slurrymixed with water proofing compound and finishing theexterior of stone slab with cement mortar 1:3 (1 cement :3 coarse sand) 20mm thick with neat cement punningmixed with water proofing compound in recommendedproportion complete at all levels and as directed byEngineer-in-charge

2.1 DSR 22.2.1 Using rough Kota stone Sqm 1800.00 647.85 1166130.00

3 DSR 22.3 Providing and laying water proofing treatment to verticaland horizontal surfaces of depressed portions of W.C.,kitchen and the like consisting of :

i) Ist course of applying cement slurry @ 4.4 Kg/sqmmixed with water proofing compound conforming to IS2645 in recommended proportions including rounding offjunction of vertical and horizontal surface.

IInd course of 20mm cement plaster 1:3 (1 cement : 3coarse sand) mixed with water proofing compound inrecommended proportion including rounding off junctionof vertical and horizontal surface.

Page 14: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

IIIrd course of applying blown or residual bitumen appliedhot at 1.7 Kg. per sqm of area.

3.1 IVth course of 400 micron thick PVC sheet. (Overlaps atjoints of PVC sheet should be 100 mm wide and pastedto each other with bitumen @ 1.7 Kg/sqm.)

Sqm 813.00 272.5 221542.50

4 DSR 22.14 Grading roof for water proofing treatment with

4.1 DSR 22.14.1

Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) Cum 400.00 3314.95 1325980.00

5 DSR 12.21.1

Providing gola 75x75 mm in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 stone aggregate 10mm anddown gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design :

5.1 In 75x75mm deep chase metre 400.00 67.35 26940.006 DSR 12.22 Making khurras 45x45 cm with average minimum

thickness of 5 cm cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate of 20 mmnominal size) over P.V.C. sheet1mx1mx400micron, finished with 12mm cement plaster1:3 (1 cement : 3 coarse sand) and a coat of neatcement rounding the edge sand making and finishing theoutlet complete

each 60.00 108 6480.00

7 DSR 12.41.2

Providing and fixing on wall face unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion.(i) Singlesocketed pipes.

7.1 110 mm diameter metre 1105.00 163.4 180557.008 Providing and fixing on wall face unplasticised - PVC

moulded fittings/ accessories for unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion.

8.1 DSR 12.42.1.2

Couplers 110 mmEach 240.00 101.65 24396.00

Page 15: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

8.2 DSR 12.42.5.2

BEND 87.5 degree ( 110 mm Bend )Each 122.00 134.2 16372.40

8.3 DSR 12.42.6.2

Shoe (Plain) 110 mmEach 122.00 263.1 32098.20

9 Providing and fixing on wall face Unplasticised - PVCmoulded fittings/ accessories for Unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion.Bend 87.5°

9.1 DSR 12.42.5.1

75 mm bend each 2.00 88.4 176.80

Shoe (Plain)9.2 DSR

12.42.6.175 mm Shoe

each 2.00 152.25 304.50

10 DSR 19.16 Providing Orange colour saftey foot rest of minimum 6thick mm Plastic encapsulated as per IS 10910 on 12mm dia steel bar conforming IS 1786 having minimumcross section as 23mm X 25 mm and over all minimumlength 263 mm and Width as 165mm with minimum112mm space between protued legs having 2mm treadon top surface by ridding chequred besides besidenecessary and adequate anchoring projections on taillength on 138mm as per standard drawing and suitablewith stand and bend test and chemical resistence test asper specifications and having manufacture's permenentidentification mark to be visible even after finishing,including fixing in manhole with 30x20x15 cm cementconcrete block 1:3:6 (1 cement: 3 course sand: 6 gradedstone aggregate 20mm nominal size) complete as perdesign

10.1 With 20 mm diameter round bar each 40.00 182.4 7296.00

11 DSR 19.18 Supplying and fixing C.I. cover without frame formanholes:

11.1 DSR 19.18.1

455x610 mm rectangular C.I. cover (light duty) theweight of the cover to be not less than 23 kg. each 3.00 1007.45 3022.35

12 DSR 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of classdesignation 75 and S.W. drain pipe 100 mm diameter,1.8 m long complete as per standard design.

12.1 DSR 19.32.1

With F.P.S. bricks each 2.00 9938.6 19877.20

Page 16: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

13 DSR 19.7 Constructing brick masonry manhole in cement mortar1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete1:4:8 mix (1 cement : 4 coarse sand : 8 graded stoneaggregate 40mm nominal size) inside plastering 12mmthick with cement mortar 1:3 (1 cement : 3 coarse sand)finished with floating coat of neat cement and makingchannels in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size)finished with a floating coat of neat cement complete asper standard design :

DSR 19.7.3 Inside size 120x90 cm and 90 cm deep including C.I.cover with frame (heavy duty) 560 mm internal diameter,total weight of cover and frame to be not less than 208kg (weight of cover 108 kg and weight of frame 100 kg) :

13.1 With F.P.S. bricks with class designation 75 each 9.00 15673.85 141064.65

14 DSR 19.8 Extra for depth for manholes

14.1 DSR 19.8.2.1

Size 120 x 90 cm with F.P.S bricks with classdesignation 75

metre 2.00 3179.95 6359.90

15 Providing and fixing square-mouth S.W. gully trap classSP-1complete with C.I. grating brick masonry chamberwith water tight C.I.cover with frame of 300 x300 mm size (inside) the weight of cover tobe not less than 4.50 kgand frame to be not less than 2.70 kg as perstandarddesign

15.1 DSR 19.4.1 100x100mm size plate

15.2 DSR 19 4 1 1

with F.P.S. bricks class designation 75 each 2.00 935.15 1870.30

16 DSR 12.43.2

Providing and fixing unplasticised -PVC pipe clips ofapproved design to unplasticised - PVC rain water pipesby means of 50x50x50mm hard wood plugs, screwedwith M.S. screws of required length including cuttingbrick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete. -110MM

Each 1200.00 96.9 116280.00

17 DSR 12.44 Providing and fixing to the inlet mouth of rain water pipecast iron grating 15 cm dia and weighing not less than440 grms

Each 120.00 23.4 2808.00

18 DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S.sheet box for ceiling fan clamp of internal dia 140mm,73mm height, top lid of 1.5mm thick M.S. sheet with itstop surface hacked for proper bonding, top lid shall bescrewed into the cast iron/ M.S. sheet box by means of3.3mm dia. round headed screws, one lock at thecorners. Clamp shall be made of 12mm dia M.S. barbent to shape as per standard drawing.

Each 100.00 81.2 8120.00

19 DSR 16.68 Providing and laying 60mm thick factory made cementconcrete interlocking paver block of M -30 grade madeby block making machine with strong vibratorycompaction and of approved size and design/ shapelaid in required colour and pattern over and including50mm thick compacted bed of course sand, filling thejoints with coarse sand etc. all complete as per thedirection of Engineer-in-charge.

sqm 1000.00 346.35 346350.00

Total C/o to Summary : Rs. 6702770.10J ROAD WORKS

1 DSR 16.1 Preparation and consolidation of subgrade with powerroad roller of 8 to 12 tonne capacity after excavatingearth to an average of 22.5 cm depth, dressing tocamber and consolidating with road roller includingmaking good the undulations etc. and rerolling thesubgrade and disposal of surplus earth lead upto 50metres.

Sqm 2400.00 33.90 81360.00

2 Supplying and stacking at site

2.1 DSR 16.3.10

Moorum Cum 40.00 421.85 16874.00

2.2 DSR 16.3.6 Stone screening 13.2 mm nominal size (Type A). cum 20.00 892.25 17845.00

Page 17: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

2.3 DSR 16.3.7 Stone screening 11.2 mm nominal size (Type B). cum 20.00 979.40 19588.00

2.4 DSR 16.3.1 90 mm to 45 mm size stone aggregate.cum 240.00 742.30 178152.00

2.5 DSR 16.3.2 63 mm to 45 mm size stone aggregate.cum 240.00 768.45 184428.00

3 DSR 16.6.1 Supply, Stacking and Spreading 6 mm thick red bajri,watering and rolling complete including preparation ofthe surface and rolling with road roller/hand roller.

Sqm 720.00 6.70 4824.00

4 DSR 16.4 Laying , spreading and compacting stone aggregate ofspecified sizes to WBM specifications includingspreading in uniform thickness, hand picking , rollingwith 3 wheeled road / vibratory roller 8-10 tonne instages to proper grade and camber, applying andbrooming requisite type of screening / binding materialto fill up interstices of coarse aggregate watering andcompacting to the required density .

cum 480.00 192.55 92424.00

5 DSR 16.43 Providing and laying design mix cement concrete inroads, taxi tracks and runways having a minimum workstest beam flexural strength of 30 kg. per cm2. at 28 daysusing not less than 340 Kg. of cement per cum offinished concrete, coarse sand and graded stoneaggregate of 40mm nominal size in appropriateproportions as per specified design criteria approved byEngineer-in-charge mechanically vibrated using needleand surface vibrators including steel form work withsturdy M. S. channel sections including curing andproviding and filling construction joints and dummy jointswith shalijet primer or equivalent including rounding ofthe edges and filling the grooves 10x25mm deep at topfor construction joints and 10mmx50mm deep at top fordummy joints with joint sealing compound (conforming tograde B of IS : 1834) including making necessaryarrangements for expansion joints etc. all complete.

cum 330 3692.40 1218492.00

6 DSR 16.44 Extra for providing and mixing hard crete of approvedquality as per manfuacture specification. Litre 2244 33.70 75622.80

7 DSR16.45 Providing and fixing in position premoulded joint filler inexpansion joints.

per cm.

depth per

7500 2.00 15000.00

8 DSR 16.46 Providing and laying in position bitumen hot sealingcompound for expansion joints etc.

per cm.

depth per

1500 1.10 1650.00

8.1 Using grade ‘A’ sealing compound.

9 DSR 19.6 Providing and laying non-pressure NP2 class (light duty)R.C.C. pipes with collars jointed with stiff mixture ofcement mortar in the proportion of 1:2 (1 cement : 2 finesand) including testing of joints etc. complete:

9.1 DSR 19.6.5 a)450 mm dia. R.C.C. pipemetre 115.00 499.55 57448.25

9.2 DSR 19.6.7 b)600 mm dia. R.C.C. pipemetre 85.00 895.10 76083.50

Total C/o to Summary : Rs. 2039791.55

K Stone Work

1 DSR 7.40 Providing and fixing dry cladding upto 10 metre heightswith 30mm thick gang saw cut stone with (machine cutedges) of uniform colour and size upto 1mx1m, fixed tostructural steel frame work and/ or with the help ofcramps, pins etc. and sealing the joints with approvedweather sealant as per Architectural drawing anddirection of Engineer-in-charge. (The steel frame work,stainless steel cramps and pins etc. shall be paid forseparately )

1.1 DSR 7.40.2 White sand stone or bansi- paharpur stoneSqm 1851.86 1382.35 2559918.67

Page 18: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

2 DSR 7.41 Providing and fixing structural steel frame (for drycladding with 30 mm thick gang saw cut with machinecut edges sand stone) on walls at all heights using M.S.square/ rectangular tube in the required pattern as perarchitectural drawing including cost of cutting, bending,welding etc. The framework shall be supported in wallwith the help of MS brackets/lugs of angle iron/ flats etc.which shall be welded to theframe and embedded inbrick wall with cement concrete block 1:2:4 (1 cement :2coarse sand :4 graded stone aggregate 20mm nominalsize) of size 300x230x300mm including cost ofnecessary centring and shuttering and with approvedexpansion hold fasteners on CC/RCC surface includingdrilling necessary holes. Approved cramps/ pinsetc. shall be welded to the framework to support stonecladding the steel work will begiven a priming coat of Zinc primer as approved byEngineer-in-charge and painted with two or more coatsof epoxy paint (Shop drawings shall be submitted by thecontractor to the Engineer-in-charge for approval beforeexecution). The frame work shall be fixed in truehorizontal & vertical lines/planes. (Only structural steelframe work shall be measured for the purpose ofpayment, stainless steel cramps shall be paid forseparately and nothing extra shall be paid.)

Kg 142450.77 77.80 11082669.85

3 DSR 7.42 Providing and fixing adjustable stainless steel cramps ofapprove quality and of required shape and sizeadjutable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stonecladding fixed on frame work at suitable locationincluding making necessary recesses in stane slab,drilling required holes etc. complete as per direction ofengineer in charge.

Each 7000.00 272.50 1907500.00

4 DSR 7.39 Extra for stone work for wall lining on exterior wallsofheight more than 10 m from ground level for everyadditional height of 3 m or part there of.

Sqm 800.00 40.75 32600.00

Total C/o to Summary : Rs. 15582688.52L PLUMBING AND SANITATION

1 Providing and fixing water closet squatting pan (Indiantype W.C. pan ) with 100mm sand cast Iron P or S trap,10 litre low level white P.V.C. flushing cistern withmanually controlled device (handle lever) conforming toIS : 7231, with all fittings and fixtures complete includingcutting and making good the walls and floors whereverrequired :

DSR 17.1.1White Vitreous china Orissa pattern W.C. pan of size580x440mm with integral type foot rests. Each 10.00 2304.65 23046.50

INTERNAL WATER SUPPLY

2 Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & coldwater supply including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one stepCPVC solvent cement and the cost of cutting chasesand making good the same including testing of jointscomplete as per direction of Engineer in charge.

Concealed work including cutting chases and makingood the walls, etc

2.1 DSR 18.8.1 15 mm nominal outer dia .Pipes. Metre 125.00 155.15 19393.75

2.2 DSR 18.8.2 20 mm nominal outer dia .Pipes. Metre 40.00 175.50 7020.00

3 Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & coldwater supply including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one stepCPVC solvent cement and the testing of joints completeas per direction of Engineer in charge.

Internal work - Exposed on wall

Page 19: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

3.1 DSR 18.7.2 20 mm nominal outer dia .Pipes. Metre 50.00 115.65 5782.50

3.2 DSR 18.7.3 25 mm nominal outer dia .Pipes. Metre 75.00 150.40 11280.00

3.3 DSR 18.7.4 32 mm nominal outer dia .Pipes. Metre 60.00 196.35 11781.00

3.4 DSR 18.7.5 40 mm nominal outer dia .Pipes. Metre 45.00 275.05 12377.25

3.5 DSR 18.7.6 50 mm nominal outer dia .Pipes. Metre 35.00 418.50 14647.50

4 Providing and fixing ball valve (brass) of approvedquality , high or low pressure, with plastic floats complete

4.1 DSR 18.18.3

25 mm nominal outer dia .pipes Each 20.00 385.90 7718.00

5 Providing & fixing gunmetal gate valve with CI wheel ofapproved quality (screwed end);

5.1 DSR 18 17 1

25 mm nominal bore Each 10.00 285.50 2855.00

5.2 DSR 18 17 2

32 mm nominal bore Each 10.00 358.00 3580.00

5.3 DSR 18.17.3

40 mm nominal bore Each 5.00 399.00 1995.00

5.4 DSR 18.17.4

50 mm nominal bore Each 5.00 578.20 2891.00

5.5 DSR 18.17.5

65 mm nominal bore Each 6.00 831.75 4990.50

5.6 DSR 18.17.6

80 mm nominal bore Each 4.00 1369.25 5477.00

EXTERNAL WATER SUPPLY

6 Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & coldwater supply including all CPVC plain & brass threadedfittings. This included jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testingof joints complete as per direction of Engineer in Charge

External work

6.1 DSR 18.9.7 62.50 mm nominal inner dia Pipes. Metre 30.00 1217.80 36534.00

6.2 DSR 18.9.8 75 mm nominal inner dia .Pipes. Metre 65.00 1590.75 103398.75

7 Constructing masonry Chamber 120x120x100 cm, insidewith 75 class designation brick work in cement mortar1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.surface box 100 mm. top diameter, 160 mm bottomdiameter and 180 mm deep ( inside) with chained lid andRCC top slab 1:2: 4 mix ( 1 cement: 2 Course sand: 4graded stone aggregate 20mm nominal size) necessaryexecavation foundation concrete 1:5:10 ( 1 cement: 5Fine sand: 10 graded stone aggregate 40mm nominalsize) and inside plastering with cement motar 1:3 (1Cement: 3 Course Sand) 12mm thick finished with afloting coat of neat cement complete as per standarddesign:

7.1 DSR 18.35.1

With F.P.S. bricks Each 2.00 8528.75 17057.50

8 Providing and fixing GUN METAL NON-RETURNVALVE of approved quality (screwed end)

8.1 DSR 18.19.5.1

65 mm nominal bore - Horizontal Each 2.00 1282.10 2564.20

8.2 DSR 18.19.5.2

65 mm nominal bore - Vertical Each 2.00 1467.95 2935.90

8.3 DSR 18.19.6.1

80 mm nominal bore - Horizontal Each 2.00 1812.25 3624.50

8.4 DSR 18.19.6.2

80 mm nominal bore - Vertical Each 2.00 2390.70 4781.40

9 Providing and fixing enclosed type water meter (bulktype) conforming to IS : 2373 and tested by MunicipalBoard complete with bolts, nuts, rubber insertions etc.(The tail pieces if required will be paid separately) :

9.1 DSR 18.60.1

80 mm dia nominal bore Each 1.00 2448.40 2448.40

9.2 DSR 18.60.2

100 mm dia nominal bore Each 1.00 3719.80 3719.80

Page 20: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

9.3 DSR 18.60.3

150 mm dia nominal bore Each 1.00 5261.80 5261.80

10 Providing and fixing C.I. dirt box strainer for bulk typewater meter with nuts, bolts, rubber insertions etc.complete conforming to IS : 2373 :

10.1 DSR 18.61.1

80 mm diaEach 1.00 3110.45 3110.45

10.2 DSR 18.61.2

100 mm dia.Each 1.00 4672.20 4672.20

10.3 DSR 18.61.3

150 mm diaEach 1.00 6067.85 6067.85

11 DSR 18.48 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked withcover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes butwithout fittings and the base support for tank.

litres 20000.00 5.25 105000.00

INTERNAL DRAINAGE

12 Providing and fixing soil, waste and vent pipes :

Centrifugally cast (spun) iron socketed pipe as per IS:3989.

12.1 DSR 17.35.1.2

100 mm dia.metre 150.00 730.40 109560.00

12.2 DSR 17.35.2.2

75 mm dia.metre 400.00 629.85 251940.00

13 Providing and fixing M.S. holder-bat clamps of approveddesign to Sand Cast iron/cast iron (spun) pipeembedded in and including cement concrete blocks10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4graded stone aggregate 20mm nominal size) includingcost of cutting holes and making good the walls, etc

13.1 DSR 17.37.1

For 100 mm dia. Pipe each 25.00 65.35 1633.75

13.2 DSR 17.37.2

For 75 mm dia. Pipeeach 70.00 63.00 4410.00

14 Providing and fixing bend of required degree with accessdoor, insertion rubber washer 3 mm thick, bolts and nutscomplete.Sand cast iron S&S as per IS - 3989

14.1 DSR 17.38.1.2

100 mmeach 50.00 291.00 14550.00

14.2 DSR 17.38.2.2

75 mm each 50.00 230.90 11545.00

15 Providing and fixing single equal plain junction ofrequired degree with access door, insertion rubberwasher 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989

15.1 DSR 17.43.1.2

100x100x100 mmeach 25.00 489.60 12240.00

15.2 DSR 17.43.2.2

75x75x75 mmeach 25.00 364.45 9111.25

16 Providing and fixing single unequal junction of requireddegree with access door, insertion rubber washer 3 mmthick, bolts and nuts complete :Sand cast iron S&S as per IS - 3989

16.1 DSR 17.47.1.2

100x100x75 mmeach 30.00 637.10 19113.00

17 Providing and fixing terminal guard:

Sand cast iron S&S as per IS - 3989

17.1 DSR 17.56.1.2

100 mmeach 65.00 194.60 12649.00

17.2 DSR 17.56.2.2

75 mm each 65.00 177.45 11534.25

18 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings ofdiameter:

Page 21: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

18.1 DSR 17.58.1

100 mmeach 120.00 126.50 15180.00

18.2 DSR 17.58.2

75 mmeach 120.00 107.80 12936.00

19 Providing and fixing M.S. stays and clamps for sand castiron/ centrifugally cast (spun) iron pipes of diameter :

19.1 DSR 17.59.1

100 mmeach 10.00 48.25 482.50

19.2 DSR 17.59.2

75 mmeach 10.00 41.55 415.50

20 Providing and fixing trap of self cleansing design withscrewed down or hinged grating with or without vent armcomplete, including cost of cutting and making good thewalls and floors :

20.1 100 mm inlet and 100 mm outlet

DSR 17.60.1.1

Sand cast iron S&S as per IS: 3989.each 110.00 544.30 59873.00

20.2 100 mm inlet and 75 mm outlet

DSR 17.60.2.1

Sand cast iron S&S as per IS - 3989 each 110.00 573.35 63068.50

EXTERNAL DRAINAGE

21

DSR 19.4

Providing and fixing square-mouth S.W. gully trap ClassSP-1 complete with C.I. grating brick masonry chamberwith water tight C.I. cover with frame of 300 x300 mmsize (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70 kg as per standarddesign :100x100 mm size P type

21.1 DSR 19.4.1.1

With F.P.S. Bricks class designation 75each 10.00 935.15 9351.50

22

DSR 19.7

Constructing brick masonry manhole in cement mortar1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete1:4:8 mix (1 cement : 4 coarse sand : 8 graded stoneaggregate 40mm nominal size) inside plastering 12mmthick with cement mortar 1:3 (1 cement : 3 coarse sand)finished with floating coat of neat cement and makingchannels in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size)finished with a floating coat of neat cement complete asper standard design :

Inside size 120x90 cm and 90 cm deep including C.I.cover with frame (medium duty) 500 mm internaldiameter, total weight of cover and frame to be not lessthan 116 kg (weight of cover 58 kg and weight of frame58 kg) :

22.1 DSR 19.7.2.1

With F.P.S. bricks class designation 75each 16.00 11882.20 190115.20

23 Extra for depth for manholes

Size 120x90 cm23.1 DSR

19.8.2.1With F.P.S. bricks class designation 75

Metre 35.00 3179.95 111298.25

24 Constructing masonry Chamber 120x120x100 cm, insidewith 75 class designation brick work in cement mortar1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.surface box 100 mm. top diameter, 160 mm bottomdiameter and 180 mm deep ( inside) with chined lid andRCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4graded stone aggregate 20 mm nominal size) necessaryexcavation foundation concrete 1:5:10 (1 cement : 5 finesand : 10 graded stone aggregate 40 mm nominal size)and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coatof neat cement complete as per standard design :

Page 22: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

DSR Item No.

Description of Item Unit Quantity Rate (in Rs.)

Amount in (Rs)

24.1 DSR 18.35.1

With F.P.S. brickseach 2.00 8528.75 17057.50

25 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of classdesignation 75 and S.W. drain pipe 100 mm diameter,1.8 m long complete as per standard design.

25.1 DSR 19.32.1

With F.P.S. bricks each 2.00 9938.60 19877.20

Total C/o to Summary : Rs. 1393953.15

Page 23: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

A Wood, Iron and Steel Works 1 Supplying and fixing in position of stainless steel

handrail assembly complete in all respect fabricatedfrom 38 mm dia (2mm thick) stainless steel verticalposts spaced at 900 mm centre to centreapproximately and welded to top with horizontalstainless steel pipe of 60 mm dia (3mm thick) andthree rows of guard rail 25 mm dia (1.63 mm thick)stainless steel pipe including welding at site, grindingand polishing etc, complete ( SS 304 NICKEL 0.8%).(for payment purpose only the running length ofhandrail will be measured) [Carl F make orequivalent]

metre 180.00

Total C/o to Summary : Rs.B JOINERY WORKS

2hr. Fire rated hollow metal doors - Painted1 Providing and fixing of Hollow metal fire rated doors

at all levels from ISO 9001-2000 certifiedManufacturer. Fire door should be as per IS 3614part-1 & part-2 and BS 476 part 2 or EN 1634.Recommended fire door shall be tested and certifiedby a third party evaluation program from approvedinternational agency like CERTIFIRE and labled.Where third party evaluation is not required fire doorsshould be tested at CBRI or ARAI for maximumrating of 2hrs both with vision panel and withoutvision panel. Pressed Galvanized steel Single/Double leaf door of approved make shakti met-doror approved equivalent which consists of frame,shutter, infill and finish as detailed below andconforming to IS 277. Door frame shall be double rebate profile of size 143x 57 mm made out of 1.60mm (16gauge) thickgalvanized steel sheet. Frames shall be Mitered andfield assembled with self tabs. All provision shouldbe mortised, drilled and tapped for receivingappropriate hardware. Rubber door silencers shouldbe provided on the striking jamb. Frames should beprovided with back plate bracket and anchorfasteners for installation on a finished plasteredmasonry wall opening. Once frame installed shouldbe grouted with cement & sand slurry necessary forfire doors on the clear masonry opening.

Door leaf shall be 46mm thick fully flush double skindoor with or without vision lite. Door leaf shall bemanufactured from 1.2mm (18guage) thickgalvanised steel sheet. The internal construction ofthe door should be rigid reinforcement pads forreceiving appropriate hardware. The infill materialshall be resin bonded honeycomb core. All doorsshall be factory prepped for receiving appropriatehardware and provided with necessary reinforcementfor hinges, locks, and door closers. The edgesshould be interlocked with a bending radius of1.4mm. For pair of doors astragals has to beprovided on the meeting stile for both active andinactive leaf. Vision lite wherever applicable shouldbe of size 200x300mm provided as permanufacturers recommendation with a beeding andscrews from inside. The glass should be 6mm clearborosilicate fire rated glass of relavant rating of thedoor with all fittings like hinges, locks, handels andtower boltsAll doors and frames shall be finished with etchedprimer coating, stove zinc phosphate primer andthermosetting polyurethane aliphatic grade paint ofapproved colour. The door leaf and frame shallhave passed minimum 250 hours of salt spraytest. as per requirement and direction of engineerin charge. The detail hardware list is enclosed (intechnical specification in section - 3 )

CONSTRUCTION OF AUDITORIUM/CONVENTION CENTRE AT NASC COMPLEX, PUSA, NEW DELHIPART-II (Non-Scheduled Items based on Market rates)

Page 24: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

a 2Hrs Fire rated door double leaf of size FD1 :2000x2400mm with vision panel

each 29.00

b 2Hrs Fire rated door double leaf of size FD2: 1500x2400mm with 200x300mm visionpanel

each 1.00

c 2Hrs Fire rated door double leaf of size FD2: 1500x2400mm with 200x300mm visionpanel

each 7.00

d 2Hrs Fire rated door double leaf of size FD1 :2000x2400mm with 200x300mm visionpanel

each 2.00

e 2Hrs Fire rated door double leaf of size FD2 :1500x2400mm 200x300mm with visionpanel

each 12.00

General doors - Painted

2 Providing and fixing of Hollow metal door at all levelsfrom ISO 9001-2000 certified Manufacturer. Allhollow metal general doors with or without visionpanel. Pressed Galvanised steel Single /Double leafto required sizes of approved make shakti met-dor orapproved equivalent which consists of frame, shutter, infill and finish as detailed below and conforming toIS 277.Door frame shall be single rebate profile ofsize 100 x 57 mm made out of 1.20mm (18gauge)thick galvanized steel sheet. Frames shall be Miteredand field assembled with self tabs. All provisionshould be mortised, drilled and tapped for receivingappropriate hardware. Rubber door silencers shouldbe provided on the striking jamb. Frames should beprovided with back plate bracket and anchorfasteners for installation on a finished plasteredmasonry wall opening. Once frame installed shouldbe grouted with cement & sand slurry necessary forfire doors on the clear masonry opening.

Door leaf should be 46mm thick fully flush doubleskin door with or without vision lite. Door leaf shall bemanufactured from 0.8mm (22 guage) thickgalvanised steel sheet. The internal construction ofthe door should be rigid with steel stiffeners/ padsand reinforcement. The infill material shall be resinbonded honeycomb core. All doors should be factoryprepped for receiving appropriate hardware andprovided with necessary reinforcement for hinges,locks, and door closers. The edges should beinterlocked with a bending radius of 1.4mm. For pairof doors astragals has to be provided on the meetingstile for both active and inactive leaf. Vision litewherever applicable should be of size 200x300mm & 150x750mm provided as per manufacturersrecommendation with a beading and screws frominside. The glass should be 6mm thick clear floatglass. The door should be complete withlocks,Hinges,panic bar, door closers,door stoppers ,handels, vision panels and tower bolts etc as perrequirement and direction of engineer in charge. Thedetail hardware list is enclosed (in technicalspecification in section - 3 )

Page 25: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

All doors and frames shall be finished with etchedprimer coating, stove zinc phosphate primer andthermosetting polyurethane aliphatic grade paint ofapproved RAL colour. The door leaf and frameshall have passed minimum 250 hours of saltspray test.Rate should include supply and installation of doorand hardware set as mentioned in the door andhardware schedule in the technical specifications(Section-3)

a

Steel door single leaf of size: D3 1000x2400mm without vision panel each 7

b

Steel door single leaf of size: D4 900x2400mm without vision panel each 7

c

Steel door single leaf of size: D3 1000x2400mm without vision panel each 7

d

Steel door single leaf of size: D4 900x2400mm without visionpanel each 7

e

Steel door single leaf of size: D3 1000x2400mm without visionpanel each 6

f

Steel door double leaf of size: D2 1500x2400mm with vision panel each 2

g

Steel door double leaf of size: D2 1500x2400mm without vision panel each 1

h

Steel door double leaf of size: D6 1500x2400mm with 200x300mm vision panel (Un Equal Shutter) each 1

i

Steel door double leaf of size: D1 2000x2400mm with 150x750mm vision panel each 22

j

Steel door double leaf of size: D1 2000x2400mm with 200x300mm vision panel each 1

k

Steel door double leaf of size: D1 2000x2400mm with 150x750mm vision panel each 2

l

Steel door double leaf of size: D2 1500x2400mm with 150x750mm vision panel each 1

m

Steel door double leaf of size: D1 2000x2400mm with 150x750mm vision panel each 1

n

Steel door single leaf of size: D4 900x2400mm with 200x300mm visionpanel each 4

Page 26: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

o

Steel door single leaf of size: D3 1000x2400mm with 200x300mm visionpanel each 5

p

Steel door single leaf of size: D3 1000x2400mm with 200x300mm visionpanel each 1

q

Steel door single leaf of size: D4 900x2400mm with 200x300mm visionpanel each 7

r

Steel door single leaf of size: D4 900x2400mm without visionpanel each 1

s

Steel door double leaf of size: D2 1500x2400mm with 200x300mm vision panel each 7

t

Steel door double leaf of size: D1 2000x2400mm with vision panel each 8

u

Steel door double leaf of size: D2 1500x2400mm with 200x300mm vision panel each 5

v

Steel door single leaf of size: D4 900x2400mm without visionpanel each 6

w

Steel door single leaf of size: D4 900x2400mm with 200x300mm visionpanel each 1

x

Steel door single leaf of size: D3 1000x2400mm without visionpanel each 8

y

Steel door double leaf of size: D1 2000x2400mm with 200x300mm vision panel each 4

z

Steel door double leaf of size: D6 1500x2400mm with vision panel (Un Equal Shutter) each 2

3 Providing and fixing of Stainless Steel toilet partitionsand cubicles with doors and hardware for fixing andmounting of the panels as manufacturespecifications and by Approved vendor. The scope ofwork includes complete in all respect and as per thedirection of Engineer in chargeConstruction of cubicles : The panels should beconstructed for 25mm and doors for 22mm thicksandwiched skin with the infill material of honeycomb core. The core should be bonded with resinand should have a flat face on either side. All panelsshould have a built in feature to be totally sight proofon all four corners for better privacy. Standard gap of150mm on sides and on the moving element has tobe provided unless otherwise specified. Cubiclesshould have a provision for mounting of the toilethardware like handrails, hinges, locks with indicator,coat hooks as specified. All panels should be fullyprotected with the self adhesive film and to beremoved at the handing over of the cubicles.

Page 27: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Type : Floor Mounted with legs: The cubicles aremounted on the Stainless Steel legs. Support barson top for stability and integrity which in turn isconnected to solid wall support. Wall brackets andcorner brackets to be used while assembling thecubicles. In addition the door should have a self-closing hinge and an indicator slip latch or bolt with aknob outside.Material / Finish / Hardware : A. All toilet partitionsand cubicles should be made out of first gradestretched level quality Stainless Steel conforming toSS304 grade. All products should be made out of0.6mm (22g) Stainless Steel sheet.Door Hardware:Heavy duty, Stainless Steel.1. Top & Bottom Hinge: Surface Mounted, withStainless Steel pin in the plane of the door.2. Latch:Surface mounted, with emergency access. 3. CoatHook and Bumper : Surface mounted 4. WallBrackets: For wall support and mounting the panels.C. Legs should be made out of Stainless Steel asspecified. D. All support and locking accessoriesshould be Stainless Steel as specified.

Installation :All cubicles should be checked fordimensional accuracy before start of installation. Anyvariations in the agreed site conditions or civilstructure should be addressed before installing thepanels and doors. The internal fittings like WCrelated works should be completed in all aspectsbefore the panels are positioned. All installation Cubicle Size is 1800 MM X 1300 MM each 65.00

4 Supplying and Fixing of Unplasticised Poly VinylChorlide (UPVC) Casement Window of approvedmake, using UPVC reinforced profiles of requiredsizes. The minimum wall thickness for the externalsurfaces shall not be less than 2.5mm. The systemmust have minimum 3 sealed chambers, for thecasement shutter and mullion section capable ofmountingsingle / double glazing system, structurallyreinforced with hot dip galvanized steel with 120GSMof miniumum thickness of 1.8mm prefabricated andwelded through fusion welding. the window shall befitted with 5mm thick tinted / float glass of reputedmake duly fitted with EPDM weathering seal andaccesories likefriction stay hinges of stainless steelgrade 304-2Nos per sash, handle with with zamakalloy casting 1 No per sash, multipoint lockingsystem suitably concealed 1 No per sash and thesystem is to be installed at site using anchorfasteners, silicon sealant, easy galzing / deglazing atsite etc., including cost and conveyance of allmaterial, accessories, labour charges fortransportation, erection at site complete for finisheditem of work

Sqm 42.00

Total C/o to Summary : Rs.C FLOORING WORKS

1 Providing and laying Vitrified Ceramic floor tiles 600mmx 600 mm (thickness to be specified by themanufacturer) of 1st quality conforming to IS :15622of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matchingpigment etc., complete.(IMOLA or its equivalent)

sqm 600.00

Page 28: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

2 Providing and fixing Ist quality ceramic vitrified walltiles conforming to IS : 15622 (thickness to bespecified by the manufacturer ) of approved make inall colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-Chargein skirting, risers of steps and dados over 12 mmthick bed of cement Mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixedwith pigment of matching shade complete. ( Size 600MM X 300 MM ) IMOLA or its equivalent

sqm 1910.00

3 Providing flooring with best quality approved colourgranite slab not less than 20 mm thick of size not less than 1200 x 900 mm/ 900 x 600/ 600x600 mm,machine cut with water ( without kerosene ) andfactory high pre-polished, set in cement mortar 1:4 to a thick not less than 20 mm (for surface contact ofthe bottom of the granite slab) as per approvedpattern/design using irrespective of size and shape,including finishing the joints with Cement Slurryand cutting, edge chamfering and polishing with tin-oxide / high gloss factory polish as permanufacturer's Specification and as directed.Grinding after laying for level adjusment shall not bepermitted.

Rate shall include for preparation of base surface &finished the surface, protection with gypsum/poplayer over plastic sheet and removing the samebefore handing over,work at all levels and asdirected by Engineer-in-charge.

sqm 2520.00

4 Extra for providing and fixing step risers and treadsin place of flooring with approved colour graniteslab of thickness not less than 20 mm in singlepiece for each step rounded or patterned as perdrawing over a bed of C.M 1:4, 20 mm thick, alledges machine cut, machine polished includingcutting, Flame the Granite in the edges to a width of25mm(Entrance steps), making groove to thespecified size in the edges( Staicase steps),chamfering and edge polishing to rough,medium,nice, acid wash and tin oxide polishing as permanufacturers specification and as directed. Rateshall include for preparation of base surface, jointingwith matching cement slurry, work at all levels etccomplete, all as directed by Engineer-in-charge.

Sadarahalli Grey/Steel grey sqm 500.00

5 Extra for providing and fixing 125 mm high skirting inplace of flooring with best quality approved colourgranite slab of thickness not less than 20 mm,machine cut and machine high pre-polished set inC.M 1:3, 12 mm thick uniformly beyond the backingmortar / plastered surface and finishing the jointswith white cement slurry at all levels and all asdirected. Rate shall include for preparation ofsurface, chasing of wall and acid cleaning, edgechamfering and polishing.

metre 1440.00

Sadarahalli Grey/Steel grey

Total C/o to Summary : Rs.D BARICADING WORKS

Page 29: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

1 Providing, supplying and fixing temporaraybarrication with GI sheet at all height up to 3.0m andsoft partition with green fibre cloth up to 17.0M forthe entire width of the proposed extension sideproviding temporary barication around the proposedconstruction with necessary GI sheet, MS Pipevertical and horizontal supports with holding clamps ,temporary barigator shall be removed aftercompletinon of project or as per directed by theclient. the entire structure to abide all the safetyregulations. contractor to ensure adequate size ofsupport member to ensure total safety of baricationfor the entire duration of project

Sqm 4500.00

Total C/o to Summary : Rs.

Page 30: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

E GLAZING WORKS1 Unitized structural glazing (for complete system) :-

Prepration of shop drawing, detailing providing andfixing Unitized structural glazing system withvision panel and vision on spandral panel shall haveInsulated Glazed unit - 24 mm thick (6mm glass + 12mm airgap+ 6mm glass) of approved make and asspecified and work shall be completed as perdirection of engineer in charge. Rate includingfixing the glass but excluding cost of supply ofglass which will be measured separately. (REFER DETAILS AT SECTION -3 TECH SPECS)INCLUDING FRAMES, SECTIONS ETC...

Sqm 1,360

2 Punched window/Strip window (System): forcomplete system prepration of shop drawing,detailing, providing and fixing Unitized structuralglazing system with Punched window / Stripwindow either on the same plane of the unitizedstructural glazing system or recessed as per drawingwith Insulated Glazed unit - 24 mm thick (6mm glass+ 12 mm airgap+ 6mm glass) of approved make andas specified and work shall be completed as perdirection of engineer in charge. Rate includingfixing the glass but excluding cost of supply ofglass which will be measured separately. (REFER DETAILS AT SECTION -3 TECH SPECS)

Sqm 50

3 Hardwares for Top hung windows: Extra rate over& above the structural glazing item above forproviding top hung openable outward shutter of sizeas shown in the approved drawing and to beprovided and fixed on the same plane of theUnitised structural glazing system with sameshade & make of glass with the specified hardwaresexcluding the cost of Insulated glazed unit specifiedand work shall be completed as per direction ofengineer in charge.(REFER DETAILS AT SECTION -3 TECH SPECS)

Each set 20

4 Insulation for Spandrel: Rock wool slab - 64Kg/cum and having 'K' value of 0.033 w/Mok - 50 mmthick wrapped with factory pressed Black glass tissueand using 1.0mm thick powder coated G.I tray withfold alround to a height of 100mm minimum asthermal insulation to be fixed behind Compositepanel cladding area as mentioned. All the edgesbetween powder coated M.S tray and frame to besealed with Non-Staining weather silicon sealant ofapproved make.(REFER DETAILS AT SECTION -3TECH SPECS)

Sqm 1,360

5 Swing / Openable door :complete system for the openable door with patchfittings. Providing and fixing the openable Double /Single leaf door with patch fittings. Rate shall includethe cost for supplying and fixing of laminated glass12.52 mm thick and having 6 mm thick as outerpanel and 5 mm thick as inner panel with interlayerof 1.52 mm thick PVB - santry Glass plus of Dubondmake. Both outer and Inner pane shall be uncoatedclear glass of Saint Gobain or Asahi make and bothpanes shall be toughened, supply & fixing ofhardwares and necessary accessories etc.. (REFER DETAILS AT SECTION -3 TECH SPECS)INCLUDING FRAMES, SECTIONS ETC...

a Double Leaf door as per the details above. Sqm 70

Page 31: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

6 Fixed window system using WCP/ 'U' channel:

Fixed window system: designing, providing andfixing "fixed window system" having laminated glass -13.52 mm thick of approved make. Rate includessupplying and fixing the laminated glass 13.52 mmthick and having 6 mm thick as outer panel and 6mm thick as inner panel with interlayer of 1.52 mmthick PVB - santry Glass plus of Dubond make. Outerpane glass shall be reflective coated glass - SunergyClear of Asahi make or ST 167 of Saint gobainmake. Inner pane shall be uncoated clear glass andboth panes shall be toughened and heat soak testedand continuous WCP at top and Aluminium 'U'channel at bottom etc.. (REFER DETAILS ATSECTION -3 TECH SPECS) INCLUDING FRAMES,SECTIONS ETC...

Sqm 500

Supply of glass

7 Glass for Structural Glazing system complete: Supply of glass as per the options given below to therespective place to fix the glass on the system asdescribed in Technical specification. Fixing the glassshall form part of the system and shall include in thecost quoted under respective item. Refer Technicalspecification for the glass performance, processing,thickness and coating of glass, tint and otherparametres like heat treatment process etc. Allpanes of glass shall be heat strengthened.Mode of Measurement : Glass on structural Glazing & others : Length andbreadth of the superficial area of the finished workshall be measured centre to centre of the grooves onthe external surface viewed externally correct to acentimetre under the respective items. Areas shallbe calculated in a square metre correct to two placesof decimal. (REFER DETAILS AT SECTION -3TECH SPECS) ETC...

Vision Panel & Spandrel Panel : Insulated Glass -24 mm thick with 6 mm thick Reflective coated glasson both surface - ET 725 of Saint Gobain orequivalent as outer pane and 12 mm airgap and 6mm thick uncoated clear glass as inner pane ofsame make. Both panes are heat strengthened. Rateexclude fixing of glass, fixing of glass shall form partthe system cost quoted. The glass will be selected atappropriate time by Client / Architect.

Sqm 1,410

8 Vision Panel & Spandrel Panel : Insulated Glass -24 mm thick with 6 mm thick Reflective coated glasson both surface - SKN 744 of Saint Gobain orequivalent as outer pane and 12 mm airgap and 6mm thick uncoated clear glass as inner pane ofsame make. Both panes are heat strengthened. Rateexclude fixing of glass, fixing of glass shall form partthe system cost quoted. The glass will be selected atappropriate time by Client / Architect. . ( REFERDETAILS AT SECTION -3 TECH SPECS)

Sqm 10

9 Laminated sandwiched composite panel (ACP)cladding systemProviding, supplying, fixing complete system (Dry wall cladding) including providing and fixing thesystem to clad the Aluminium composite panel (ACPwith Mineral Core) as per the specification on the.external surface the external surface like column,wall, jambs, sills, projected area, ceiling or anysurface to any profile and shape, horizontally,vertically, sloped, curved, circular etc complete.(REFER DETAILS AT SECTION -3 TECH SPECS)INCLUDING FRAMES ,SECTIONS ETC...

Sqm 2,800.00

Page 32: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

10 Providing, supplying, fixing complete systemincluding providing and fixing Aluminium compositepanel (ACP with Mineral Core) to clad the externalsurface of the Canopy, screen wall and Pergola asper profile and shape shown in the Drawing withnecessary Hot dip Galvanised Structural steelsupport to clad the ACP and all support to bedesigned to withstand the Design wind pressure andthe specification specified above etc complete. Basesupport will be measured under respective itemseparately.NOTE :- Base structural steel frame work for ACPcladding covered under this item shall be measuredseparately under the respective Item, but the framework required for cladding shall be part Items ratequoted in this items. (REFER DETAILS ATSECTION -3 TECH SPECS) INCLUDING FRAMESSECTIONS ETC

Sqm 100.00

11 providing and applying Cold Bituminous coating(Vapour barrier) on the External wall behindComposite panel cladding area etc as mentioned.(REFER DETAILS AT SECTION -3 TECH SPECS)

Sqm 2,820

12 providing and fixing in position Hot rolled structuralsteel Members / Sections at all levels. (REFER DETAILS AT SECTION -3 TECH SPECS) INCLUDING FRAMES, SECTIONS ETC…

Kg 25

Total C/o to Summary : Rs.F Insulation, Granite Cladding

Insulation

1 Providing and fixing Rock wool - 50 mm thick - 64 Kg/ cum and having ‘K’ value of 0.023 w / M deg k ofapproved make conforming to IS - 8183 / BS 3958 /ASTM C 612 on the spandrel panel area i.e, behindthe ACP / glass and for smoke seal at sill level.These wool should be covered with Black tissuefactory pressed - 0.50 mm thick (Nominal Mass - 60Kg/cum) to conform Non combustibility Class - firerating to BS 476 - part 7 & IS 3808 and fixed by usingGI Angle / channel of required size as base and thewool shall be tied with 22 gauge G.I. wire in criss-cross manner into Galvanised angle / Channel tothe structure and shall be covered with powdercoated M.S sheet 1mm thick. Rock wool should befixed to the main aluminium frame work betweenmullion & transom on each side with the gap of 25 to30 mm from the inner surface of the Glass/ACP (i.ebehind the spandrel panel glass / ACP area / stonecladding). Insulation tray shall be fixed in betweenthe transoms & mullions and tray shall have fold onall 4 sides to the extend of 75mm on all 3 sides and100 mm at bottom.

Sqm 110.00

Page 33: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Granite Cladding

1 Providing and fixing Granite slab - Dry type fixingusing approved colour granite slab (Basic cost ofGranite not less than Rs.200/- per sq.ft) thickness as specified in Schedule of Quantities and size as perdrawing subject to the size of slab is not less than600x600 mm to the maximum extent. Rate shallinclude providing smaller size of granite ifnecessitated to form a Patten or at corners and noextra cost is payable, if any additional cutting,polishing is involved. Each granite slab is to beindividually supported using 4 Nos.of stainless steelclamps of size 75 x 50 x 5 mm two each at top andbottom with necessary SS screws & bolts and all SSshall be 300 series - 316 Grade. Each SS clamp willbe fixed to the wall using two numbers of MSoxidized non-corrosive expansion anchor fastenersof size 10 mm head, 6 mm dia. and 100 mm lengthfor masonry work , 10 mm head, 6 mm dia. and 75mm length for RCC areas. SS clamps with thelipping of 12 mm height shall be fixed into the Granite at the top & bottom in the cut groove on the granitewith groove cut is being 20mm long, 8mm wide.

Any corner or junction slab which may be of smallersize should also be supported similarly. Each slabwill also have similar 2 clamps at the top, balancegaps in the grooves after placing the Clamps in thegranite shall be filled with suitable adhesive ofapproved make to ensure that the clamps are fixedstable and not loosened. There will be no gaps seenbetween the granite slabs in elevation or provide 3mm Gap between the Granite slabs as directed. Allthe edges of the Granite slab shall have "V" cut orHalf / Full round chamfered finish both horizontal andvertical joints. It has to be ensured that the slabs areperfectly vertical and in plumb. Gaps between thegranite slabs are to be filled with clear silicone nonstaining sealant of approved make and all as permanufacturer specifications. Rate shall includeproviding the Granite slab matching the groove /elevation lines to close the gaps on the top and sidesto prevent water or any insects coming through thegap between wall and Dry fixing Granite.

Rate shall include for using the water cut Graniteslab (Kerosine cut not permitted either at factory or atsite), procuring the Granite from well recognizedapproved quarry / supplier’s with control over quarryand mixing of quarry / supplier’s for same shadeshall not be permitted under no circumstances andalso to be ensured that the shade of Graniteprocured from single source will be uniform and nocolour or pattern variation and charges for groovecutting in granite to fix SS clamps, Chamfering, edgepolishing, fabrication and fixing of SS clamps, anchorfasteners, double scaffolding to the required heights,wastages, work at all levels and heights, cleaning thesurface, protection of the Granite slab from anydamage till taken over by the Employer includingdesigning the entire system to withstand the designwind pressure as desired by the Structural engineeretc complete.

a Cladding the external surface like column, wall,jambs, sills, projected area or any surface to anyprofile and shape, horizontally, vertically, sloped,curved, circular etc with Granite slab - not less than25 mm thick of approved colour with the sizematching to the Structural glazing line as shown inthe Drawing and providing the Granite slab on thesame plane of the Structural Glazing system etccomplete and as directed.

Sqm 20.00

Total C/o to Summary: Rs.

Page 34: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

G PLUMBING AND SANITATION1 Providing , fixing, testing and commissioning of white

vitreous china glazed wall mounted type watercloset (European type) of approved makeconforming to IS 2556-Part 16 with seat cover andCP brass hinges and rubber buffers, complete withConcealed flushing cistern with pushbutton,complete with supply of necessary fittings,supporting bolts /CI / MS brackets flushing pipe withfittings and clamps, overflow arrangementand anglecock of approved make and finish,together with cpconncetion pipe to the cistern etc cutting andmaking good the walls and floors wherever requiredall complete as per specification and direction of theEngineer-in-Charge. ( FOR VVIP/VIP /GREENROOM )WALL HUNG MODELS FROM (ROCA / DURAVIT /TOTO) each 15.00

Soft Close seat cover Models from ( ROCA /DURAVIT / TOTO)

2 Providing , fixing, testing and commissioning of whitevitreous china glazed free standing type watercloset (European type) of approved makeconforming to IS 2556-Part 16 with seat cover andCP brass hinges and rubber buffers, complete withintegral flushing cistern (dual flush)with lid,completewith supply of necessary fittings, supporting bolts /CI/ MS brackets flushing pipe with fittings and clamps,overflow arrangementand angle cock of approvedmake and finish,together with cp conncetion pipe tothe cistern etc cutting and making good the wallsand floors wherever required all complete as perspecification and direction of the Engineer-in-Charge.

Free Standing WC ( ROCA / DURAVIT / TOTO) Each 57.00Seat cover Models from ( ROCA / DURAVIT /TOTO)

3 Supplying, Installing, testing and commissioning ofWhite color Floor Mounted European water closetwith inbuilt low level flushing cistern and WashBasin for Physically Challenged Persons (Matrix)with necessary Grab Rails, hinged rails for support ,pan connecter bend,checknut, stopcock etc., coloursolid seat and cover with polythene buffer and flap,CP flanges, CP bolts and nuts, bracket with nuts andbolts wall flanges etc.,complete, Wash Basin shallinclude 15mm dia CP liver operated pillar Cock withwaste coupling, 32mm dia CP bottle trap withextension pipe,supporting bracket with necessarysteel to support basin 1 No.15mm CP angle valvewith 450mm long CP connection pipe and CP wallflanges all of approved make etc., complete.

Each 6.00

(ROCA / DURAVIT / TOTO)

4 Providing , fixing, testing and commissioning ofWhite color Wash basin size 500x380mm(below counter ) type with 32mm dia CP waste coupling,32mm dia CP bottle trap with extension pipe, pair ofstainless steel bolts,with bracket (MS /CI ) to supportto the basin, 15mm CP angle valve with CP inletconnection tube , CP wall flange, includingnecessary brakets etc complete (For VIP/VVIP andGreen Room)

UNDER COUNTER BASIN 500 X 380MM From(ROCA / DURAVIT / TOTO) Each 18.00

Sensor faucet/ basin mixer (ROCA/TOTO/GROHE) Waste Coupling (Jaguar/ROCA/TOTO /GROHE)

CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)

Page 35: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Providing , fixing, testing and commissioning ofWhite color Wash basin size 500x380mm(below counter ) type with 32mm dia CP waste coupling,32mm dia CP bottle trap with extension pipe, pair ofstainless steel bolts,with bracket (MS /CI ) to supportto the basin, 15mm CP angle valve with CP inletconnection tube , CP wall flange, includingnecessary brakets etc complete

UNDER COUNTER BASIN 560MM X 420 MM(ROCA/DURAVIT/ TOTO/) MONOJET single lever mono block basin mixer withPop-up (ROCA/ TOTO/GROHE)Waste Coupling(Jaguar/ROCA/TOTO/GROHE)

CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)

Each 62.00

6 Supplying,installing,testing and commissioning ofbib cock for common areas, kitchen includingnecessary accessories etc.complete. Bib Cock(Jaguar/ROCA/TOTO/GROHE)

Each 20.00

Providing, fixing ,testing and commissioning ofUrinal with integrated electronic flushing system(sensor) ,integrated spreader, bottle trap, bottle trappipe, waste coupling, urinal waste pipe, one pair ofbrackets, CP caps, unions etc. complete. the Itemincludes necessary fitttings for proper installationsetc. including chasing and making good thewalls,and floors wherever required all complete asper specification and direction of the Engineer-in-Charge.

Each 30.00

Urinal sensor Model from (ROCA/ TOTO/GROHE)

CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)8 Providing, fixing ,testing and commissioning of

Urinal with integrated spreader bottle trap, bottle trappipe, waste coupling, urinal waste pipe, one pair ofbrackets, CP caps, unions and urnial auto closingpush cock etc. complete. the Item includesnecessary fitttings for proper installations etc.including chasing and making good the walls,andfloors wherever required all complete as perspecification and direction of the Engineer-in-Charge.

Each 80.00

Flat back Large urinal (ROCA/DURAVIT/ TOTO/) CP bottle trap(Jaguar/ROCA/TOTO/GROHE)

CP urinal valve auto closing system with built-in cock-Pressmatic taps (Jaguar/ROCA/TOTO /GROHE)

9 Supplying , fixing best quality mirror of approvedmake of size 600 mm x 450 mm ,'thickness 6mmfixed in plastic frame, colour 'matching with tilesabove the wash basin fixed to 6mm thick plywoodsheet with CP hooks.complete with CP screws.

(The frame shall be approved the Engineer incharge)

Each 80.00

10 Supplying , fixing in position and testing C.P. healthfaucet with wall hook one metre long flexible tube,angle cock with wall flange all complete includingcutting and making good the walls whereverrequired.

Each 78.00

CP Health Faucet (ROCA /TOTO/Grohe/Jaguar) Angle Cock

11 Providing and fixing CP exposed type Toilet paperholder with necessary screws etc., Each 78.00

5

7

Page 36: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Toilet paper holder with Flap (ROCA /TOTO/Grohe/Jaguar)

12 Supplying and fixing CP Double Coat hook fixingwith necessary screws etc., complete

Each 78.00

CP Double Coat hook (ROCA /TOTO /Grohe/Jaguar)

13 Providng and fixing 600mm long CP towel railcomplete with brackets fixed to wooden cleats withCP brass screws with concealed fitting arangementof approved quality colour and make.

Each 80.00

Towel Rail 600 mm long (ROCA /TOTO/Grohe/Jaguar)

14 Providing and fixing liquid soap container of approved make near wash basins withnecessaryfixing screws and clamps etc., complete.(ROCA /TOTO /Grohe/Jaguar)

Each 80.00

INTERNAL WATER SUPPLY15 Providing and fixing ball valve (brass) of approved

quality , high or low pressure, with plastic floatscomplete

a 32 mm nominal outer dia .pipesEach 20.00

b 40 mm nominal outer dia .pipesEach 10.00

c 50 mm nominal outer dia .pipesEach 10.00

EXTERNAL WATER SUPPLY 16 Supplying,fixing of RB make Brass 'Y' strainer on

delivery line etc., complete65mm dia

Each 1.00

a Supplying and wrapping Vidoflex insulation for hotwater line in inside toilet, running in terrace&verticaletc., complete

b For 20mm dia (ID)-CPVC pipe:22mm(ID)10mmthickness insulation RMT 60.00

c For 25mm dia (ID)-CPVC pipe:32mm(ID)10mmthickness insulation RMT 60.00

d For 32mm dia (ID)-CPVC pipe:42mm(ID)10mmthickness insulation RMT 60.00

17 Supplying and fixing Hitech pipe supports includingrequired size of rail, no of rail legs grouting / anchorfastners type,bolts,washer and nuts, Fixed in shaft ,suspended in ceiling and terrace etc.complete

a 1.6 x 300 STD/HTWB with two legsEach 15.00

b 1.6 x 500 STD/HTWB with two legsEach 15.00

c 1.6 x 600 STD/HTWB with two legsEach 15.00

Page 37: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

d 2 x 1000 STD/HTWB with two legsEach 15.00

e 3 x 1800 STD/HTWB with two legsEach 15.00

f 3x 2000 STD/HTWB with two legsEach 15.00

18 Supplying,instaling,testing and commissioning ofSolar Water Heater of Tata BP make or equivalentin quality and specification and as per directionof Engineer in charge- Flat plate collector model.An insulated storage tank is also to be provided forcollecting hot water.Electrical back up is also to beprovided. Works including loading the solar heaterpanel and tocesories,locating very near of water tankin terrace floor and making good to the inlet andoutlet connections including cost and conveyance ofall materials to the site, all labour charges, all taxesetc., complete as directed by the Engineer In-Charge.

2000lit.capacity Solar Water heater- Flat PlateColector model (Copper tube)-Temp-60 degreecelcius.(For Normal Temperature)

Each 2.00

19 Supplying and erection of power horizontal \vertical centrifugal pump set of approved makewith all accessories including fixing and jointingcable with proper clamp upto the starter to requireddepth and also fixing of riser pipes to the requireddepth, valves, erection clamps, pressure guagesupto exterior wall of pump room and erection ofpanel consisting of TPICN switches, starter,volumeter,ammeter, three pilot(indicator) lamps,capacitor, single face preventer, water level guardand laying and jointing the cable and twin earthingas per IE rules, etc., complete and testing the pumpset etc. (The contractor has to give the suitabledesign calculation for selecting the pump)

Discharge 12 lit / sec Head 40mt (1W+1S)Each 2.00

INTERNAL DRAINAGE20 Supplying,fixing and testing of Urinal trap (Sealed

Trap) used in sunken floors 110mm dia extensionboss tee arrangements with female thread fix withthe Staninless steel/upvc clean out plug in malethread with gascet and three ss screws for urinals,etc., complete

each 50.00

21 Supplying,fixing and testing of UPVC floor clean outused in sunken floors, 75 or 110mm dia extensionboss tee arrangements with female thread fix withthe upvc clean out plug in male thread with gascetand three ss screws for sunken floors etc. complete

each 60.00

EXTERNAL DRAINAGE

22 Providing fixing and testing UPVC SWR - B classpressure rating 10 kg/sqm pipe of approved makeconfirming to IS 13592-1992. and fittings confirmingto IS 14735-1999, such as coupler, elbow, bends,tee, Y, vent cowl, etc for soil, waste, vent and rainwater pipe works in shaft and suspended in ceiling,laid in ground (from shaft to inspection chamber andgully chamber), etc. using rubber ring joints (rubberring confirming to IS 15382) for shafts lines andsolvent cement joints for suspended lines and workin below ground. Works includes necessaryscaffolding, cutting and making good the wallswherever required all complete as directed by EIC.The quoted rate shall also necessary excavationcompaction and back filling, etc complete .

a) 160mmMetre 120.00

Page 38: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Total C/o to Summary : Rs.H BORE WELL WORKS 1 Construction of tubewell by drilling 300mm dia bore

by DTH/reverse roratory or any other method in allkind of soil, soft rock, hard rock etc. upto depth of180mtrs.(ii) Supplying, lowering blind and slotted200mm dia ERW-MS 5.4 mm th. pipe conforming toIS:3589-i-1991(ISI marked) coated with anti-coorosive black bitumastic paint, threaded andsocketed joining and welding including coat of alllaccesories, T&P required for job as per siteconditions including supplying/fixing 80mm dia GIdelivery pipe(50m long) medium class (Class-B)conforming to IS:1239 of JINDAL/SWASTIK makewith all fittings and valves, flanges etc. compatiblecable, control panle with motor starter, incomingmain MCCB, voltmeter/Ammeter and makingconnection with motor etc. complete (iv) Supplying,shrouding andpacking of pea gravel alround theannular space of casing pipe (v) Development ofborewell with high pressure compressor/OP unit tillthe clean/sand free water supply obtained andapproved by the Engineer-in charge. (vi) Stratasample drawn and preserved after 3 mtrs. of boring.The samples shall be sent to approved laboratory forphysical, chemical and biological test. The resultachieved shall be as per the specifications &satisfaction of Engineer-incharge (vii) Supplying &fixing MS cap on 200 mm dia housing pipe as perIS:226-1975, bail plug, clamps, centring guide &handed over to the department. The work shall betreated as completed only after the defect liabilityperiod as decided by the concerned authority is over

Job 1.00

2Add or beyond or lessor depth instead of 180 mtr. Oftube well as per the direction of Engineer incharge. mtr 10

3 Supplying and erection of power submersiblepumpset of approved make with all accessories inborewell including fixing and jointing submersiblecable with proper clamps upto the starter to requireddepth and also fixing of riser pipes to the requireddepth valves erection clamps, pressure gauges uptoexterior wall of pump room and erection of panelboard consisting of TPICN switches starter,volumeter, Ammeter, three pilot (indicator) lampscapacitor single phasing preventor, water level guardand laying and jointing the cables and twin earthingas per IE rules etc, complete and testing thepumpset and trail run for 10days(The contractor hasto give the suitable design calculation for selectingthe Pump.)

10LPS to a head of 160m to 200m

each 2.00

Total C/o to Summary : Rs.

Page 39: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

I PUMPS, VALVES, ELECTRICAL PANELS & CABLES.

ELECTRICAL DRIVEN PUMP

1

Supply, installation, testing, commissioning ofelectrically driven pump set as per specification. MotorTEFC type, 2900 rpm, 415V, 50 cycle frequency 3phase class ‘F’ insulation, I.P. 54 protection, 100 HP,starting on DOL. The Pump shall be horizontal, endsuction, top discharge. The pump shall have cast ironcasing, bronze impeller, steel shaft with common baseframe capable of discharging 137 m3 per hour at 88 Mhead.

No. 1

DIESEL ENGINE PUMP

2

Supply,installation,testing,commissioning of dieselengine driven pump set as per specification.The engineshould have RPM between 1800 to 2100.The Pumpshall be horizontal end suction, top discharge mountedon common baseframe. Pump shall be directly coupledto diesel engine of suitable HP as per system designcondition. Engine shall be complete with flywheel,spider coupling, Air cleaners, Water cooled, HeatExchanger, Corrosion Resistor, Oil Sump with lube atpump. Governor, Fuel Filter,Battery,Battery charger,starting motor battery charging alternator & instrumentpanel suitable for 24 volt DC including startingswitches,Diesel tank, lube oil temperature gauge,lubeoil pressure & high water temperature including flexibleexhaust connection.The pump shall be capable todelivery 137m3/hr. at 88 M head.

No. 1

JOCKEY PUMP:

3

Supply, installation, testing and commissioning ofelectrically driven pump set as per specification. MotorTEFC type, 2900 RPM 415 V, 50 cycles, 3 phase, class‘F’ insulation, IP 54 protection, 20 HP starting on DOL.The Pump shall be horizontal end suction topdischarge. The pump shall have cast iron casing, Castiron impeller, steel shaft.with common base framecapable of discharging 10.8 m3/hour at 88 M head.

No. 1

BOOSTER PUMP

4

Supply, installation, testing & commissioning ofelectrically driven pumpset as per specification. MotorTEFC type, 2900 RPM, 415 V 50 cycle, 3 phase Class'F" insulation, IP - 55 protection, 15HP starting on DOL.The Pump shall be horizontal, end suction, topdischarge. The pump shall be cast iron casing, bronzeimpeller, steel shaft. with common base frame capableof discharging 27 m3/hour at 45 m head. Pump to beinstalled at Terrace.

Nos. 1

MOTOR CONTROL CENTRE (MCC PANEL)

5

Supply installation testing and commissioning ofsectionalised cubicle type floor mounted front operateddust and vermin proof power cum control panel madeout of not less than 1.6mm MS sheet with enamelledfinish i/c. one coat of primer of approved shade andcolour i/c. providing suitable number of switchgears,busbars, auxilliary switches, audio alarm hooters, visualindications, relays, contactors, timers of suitablecapacity for automatic operation of pumps i/c.connections along with provision to link with IBMS andall connected accessories.Incoming315A 4P,35KA MCCB with all other required accessories - 2nos 1set of mechanical interlock(2 locks with 1 key) arrangement Instruments panel Digital type ammeter,voltmeter,selectorswitches,CTs,control fuses,one set of R,Y,B Indicatinglamps with control switches for common load side andone set of ON/OFF/TRIP indicating lamp will protectivefuses for each incomer

PART-II (Non-Scheduled Items based on Market rates (FIRE PROTECTION SYSTEM)

Page 40: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

Water level indicator and switch to prevent dry runningof fire pump i/c audio and visual alarm. 2x12V,18 AHLead acid battery for operating control panel.This shallbe independent of the engine starting battery and shallremain trickle charged from common battery chargerstatus selector switch for each pump for automatic aswell as manual operation. Pumps when under manualstatus shall be operated manually through relevant pushbuttons.Lock out indication for electric fire pump as wellas audio alarm with silencing facility. Manual resettingpush button for return to normal operation of locked outunit as reqd. Terminal facility for repeat indicator ofvarious audio and visual indications. 630A TPNAluminium busbars:All the neutral busbars shall havethe same capacity of phase busbars. Outgoing63A TP&N MCCB 25 KA with fully automatic DOLStarter suitable for jockey pump with ON/OFF/TRIPindicating lamps,ON/OFF push buttons and all otherrequired accessories -1No 160A TP&N MCCB 35 KAwith 75 HP fully automatic DOL starter withON/OFF/TRIP indicating lamps,ON/OFF push buttonsand all other required accessories-2Nos.32A TP&NMCCB 25 KA with all other required accessories withone set of ON/OFF/TRIP indicating lamp with protectivefuses-1 No, 63A TP&N MCCB 25 KA with fullyautomatic DOL starter suitable for booster pump withON/OFF/TRIP indicating lamps ,ON/OFF push buttonsand all other required accessories -1No, With necessaryAluminium busbars,interconnections, earthing etc.,withrequired accessories as per specifications. Spare 63ATP&N MCCB 25 KA with fully automatic DOL Starterfor pump with ON/OFF/TRIP indicating lamps,ON/OFFpush buttons and all other required accessories-1 no.

All indicating lamps shall be of LED type.Panel should be powder coated. No. 1

DIESEL ENGINE AUTO START PANEL

6

Supply and installation of Autostart panel for the dieselengine complete with auto/manual switch, indicationlamps protective fuses with battery charger, suitable ofworking on 230 V, AC, single phase, enclosure beingvermin & dust proof. Also potential free conducts shallbe provided for connecting to the building automationsystem

No. 1

7 CABLES :Supply, laying, testing and commissioning of thefollowing sizes of cables on surface of wall or cable tray

7.1

3.5C x 75 sq.mm XLPE Ins. Alu. armoured Cable

Rmt. 30

7.2

3.5C x 25 sq.mm XLPE Ins. Alu. armoured Cable

Rmt. 350

7.3

2 core X1.5Sq.mm PVC copper armoured cable

Rmt. 30

Page 41: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

7.4

3 core X1.5Sq.mm PVC copper armoured cable

Rmt. 30

7.5

4 core X1.5Sq.mm PVC copper armoured cable

Rmt. 30

8 CABLE TERMINATION :

Supply termination and commissioning of the followingsize cable double compression glands and crimpingsocket with suitable earth clipp & fixing accessories.

8.1 3.5C x 75sq.mm XLPE Ins. Alu. armoured Cable

Nos 2

8.2 3.5C x 25 sq.mm XLPE Ins. Alu. armoured Cable

Nos 2

8.3 2 core X1.5Sq.mm PVC copper armoured cable

Nos 2

8.4 3 core X1.5Sq.mm PVC copper armoured cable

Nos 2

8.5 4 core X1.5Sq.mm PVC copper armoured cable

Nos 6

EARTHING :

9

Providing and fixing 6 SWG copper earth wire onsurface / recess for loop earthing as required.

Rmt. 50

10

Supply and laying 25 x 5 mm copper strip for Earthing ofthe Electrical Motor MCC / Autostart Panel.

Rmt. 75

11

Suppling and fixing of cable tray 32 x 32 x 2 mm slottedangle MS painted including anchor fasteners, supportsfor wall and ceiling galvinsied Bolts and nuts etc Rmt. 20

Page 42: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

12

Supply & Installation of Cast iron sluice valve includingmaking necessary flanged joints by providing necessarynuts, bolts, gaskets, etc. all complete as perspecification

12.1

300 NB, PN 1.6 rating

Nos. 2

12.2

200 NB, PN 1.6 rating

Nos. 2

12.3

150 NB, PN 1.6 rating

Nos. 8

12.4

100 NB, PN 1.6 rating

No. 2

12.5

80 NB, PN 1.6 rating

No. 1

12.6

65 NB, PN 1.6 rating

Nos. 1

50 NB, PN 1.6 rating

Nos. 4

13

Supply & installation of Cast Iron Butterfly Valvesincluding matching flanged joints by providingnecessary nuts, bolts, gaskets (1.5 mm CAF) etc. Allcomplete as per specifications.

13.1 150NB

Nos. 30

13.2 65NB

Nos. 4

13.3 50 NB

Nos. 3

14

Suplying & installation of Cast Iron Non-Return Valvesincluding making flanged joints by providing necessarynuts, bolts, gaskets etc. All complete as perspecifications.

14.1 150NB

Nos. 8

14.2 50NB

Nos. 4

15 Providing & installation of gunmetal gate valve havingscrewed ends

15.1 65 NB.

Nos. 8

15.2 50 NB.

Nos. 16

16

Supply & installation of 3Nos Differential Pressureswitch with 80NB Manifold, 150dia dial pressure gauge,Bronze check valve with 2mm Orifice, Stainless Steelpresssure sensing piping 15mm dia required length asshown in drawing.

Sets 3

17 Supply & installation of 20 mm dia CI Automatic AirRelease Valve to all wet risers all complete as perspecifications.

Nos. 20

Page 43: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

18

Under Ground piping - Supply, erection, testing andinstallation of MS pipes conforming to IS 3589 for200NB & above and IS 1239 Class 'C' MS pipes for150NB & below with welded joints including cutting thepipes to correct length, providing and welding flanges topipe, fixing with clamps to MS brackets/ hangers,making flanged joints with necessary nuts, bolts,gaskets,. blank flanges, etc. Rates including 10%radiograph all complete as per specifications of thefollowing diameters.

a 150 NB - Class C Rmt 550

b 80 NB - Class C Rmt 15

19

For above Ground pipe: Supply, fabrication &installation of Class 'C' MS black pipe confirming to IS1239 including cutting, welding MS flanges fixing inpump room and yard and wherever necessary nuts,bolts, gaskets. Rates inclusive of heavy class fittings,steel suppots with painting, anchor bolts, hitec supports,clamping etc as per specification.Rate shall be inclusiveof Zinc chromate primer over that 2 coats red enamelpanit as per Fire authorities requirement for aboveground pipes.

a 400 NB - 6 mm thick Rmt 10

b 300 NB - 6 mm thick Rmt 5

c 200 NB - 6 mm thick Rmt 15

d 150 NB - Class C Rmt 180

e 100 NB - Class C Rmt 12

f 80 NB - Class C Rmt 225

g 65 NB - Class C Rmt 13

h 50 NB - Class C Rmt 14

i 40NB - Class C Rmt 25

20

Supply, installation, testing and commissioning ofcourtyard Gun metal Single headed hydrant as per IS:5290 consisting of 63NB single outlet flanged obliquetype hydrants valve with instantaneous female plungertype coupling, chained blank cap including makingflanged joints by providing necessary nuts, bolts,gaskets all complete as per specifications.

Nos. 12

21

Supply & installation of RRL type-A hose cabinet of63mm dia. x 15 meters long with heavy quality gunmetal male coupling of IS: 903. combined with 2 Nos ofCanvass hoses and 1 No. of nozzle.

Nos. 12

22

Supply&installation of fabricated 18SWG MS sheet ofsize 750x600x250 with glass fronted door, withsysnthetic enamel / with a coat of primer painted in redout side and white in inside, hose boxes along with GIsupport angles for courtyard hydrants. Each box shallbe capable to accommodate 2 hose each of 63 mm diax 15 m long hose pipe, nozzle, branch pipe etc.

Nos. 12

Page 44: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

23

Supply & installation of 63mm dia. approved make GMsingle headed fire hydrant landing valves (withinstantaneous female plunger type couplings, chainedblank caps) including making flanged joints by providingnecessary nuts, bolts, gaskets, etc. painting completeas per specifications.

Nos. 24

24

Supply & installation of RRL type-A hose cabinet of63mm dia. x 15 meters long with heavy quality gunmetal male coupling of IS: 903. combined with 2 Nos ofCanvass hoses with painted MS hose tray and 1 No. ofnozzle.

Nos. 24

25

Supply & Installation of drum type wall mounting hosereels, swiveling 180o consisting of 25 mm dia. x 30meters long armored rubber hose pipe with 15 mm dia.bronze shut of type jet nozzle & cut-off valve on the inletincluding making connection to the wet riser, by drillingwelding, fixing the hose reel to the wall by providingnecessary anchor fasteners/ expansion bolts, groutingthe same with cement mortar, painting all complete asper drawings, specifications.

Nos. 24

27

Supply & installation of Siamese inlet (Fire Brigade inlet) connection with provision for Four male instantaneouscoupling fabricated out of 150 mm dia. approved makeheavy class MS pipe with non-return valve, for firefighting system including making connection byproviding necessary piping & fittings to the fire storagetank, fire fighting wet riser, sprinkler system painting thesame with 3 coats of enamel paint over a coat of ZincChromate primer all complete as per drawings,specifications.Connection to Fire Tanks / YardHydrants.Fire brigade body and NRV will be made ofgun metal.

Nos. 6

28

Supply and wrapping of Coating & Wrapping Materialsmanufactured as per IS 10221 (make:Pypkote) 4mmthick for underground Pipes as per specification Steelpipelines to be laid underground buried in the soil shallbe protected against corrosion by means of coating &wrapping as per IS:10221.The above coating and wrapping shall be carried outin systematic manner such that uniform thickness ofcoating is obtained as per IS specification.Buried pipelines shall be laid in general with top ofpipe 1(one) meter below the ground level. Wheresoil conditions are not satisfactory, masonry orequivalent supports shall be provided at regularintervals.The rate shall be inclusive of Holiday test forunderground pipes.

Sqm. 340

29Excavation of earth and refilling with river sand 250 mmabove and below of pipe then with earth compactionupto formed ground level.

Cu.m. 750

30 Supply and installation of Orifice plate made out ofstainless steel 5mm thick 100 NB dia Nos. 12

31

Construction of valve chambers with 345m thick brickwall in CM 1:5,200mm thick PCC base of 1:4:8 andinternal size of 1m x 1m x1.3m depth with heavy duty CIcover as per specification.Internal walls to be plasteredin CM 1:4.

Nos. 6

32Supply and erection of Hume pipes (NP3 class ) oflength 3 meters for the following diameters

a 300mm dia Hume Pipe Nos 10

33Supply and installaiton of Steel supports for piping likeclamps, tierods,brackets, nuts and bolts as per detailsgiven in the drawings

kg 750

III SPRINKLER SYSTEM

Page 45: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

34

Supply, erection, testing and installation of heavy classblack steel pipes conforming to IS 1239 with weldedjoints including cutting the pipes to correct lengths,fixing with clamps to MS brackets / hangers, steelsupports, hitec supports as per drawing. The hydrotesting shall be done at 18 kgs/cm2 pressure. Rate shallbe inclusive of Zinc chromate primer over that 2 coatsred enamel panit as per Fire authorities requirementover all above ground pies.Rates to inclusive of allcomplete as per specifications (including heavy classforged fittings of IS standards) of the followingdiameters.

a 150 NB- Class C Rmt 988

b 100 NB - Class C Rmt 548

c 80NB - Class C Rmt 544

d 65 NB - Class C Rmt 767

e 50 NB - Class C Rmt 1248

f 40 NB - Class C Rmt 1988

g 32 NB - Class C Rmt 24

h 25 NB - Class C Rmt 6263

35

Supply and installation of Pendant type Sprinkler headwith the following temperature rating & respond,universal deflector, chromium finish as perspecifications. Size: 15-mm dia. The rate shall beinclusive of Stainless steel Rossette plate in office areaand other false ceiling areas. Temperature Rating: 68°CStandard respond

Nos. 1386

36Supply, erection, testing and commissioning ofTemperature Rating: 68°C standard response Uprightsprinklers for office area.

Nos. 1412

Page 46: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

37

Supplying & installing of approved make flow switches(flow sensors) suitable to be fixed directly on line of thefollowing diameters, with 1 NO & 1 NC potential freecontacts

a 150 NB Nos. 16

38

Supply & installation of sprinkler annunciator panelconsisting of 50 windows, capable of working on 230V AC single phase supply and provided with batteryback-up of 24 V complete as per specification. Eachwindows shall be provided with potential free contact forconnecting to the BMS system

Lot 1

39

Supply & installation of Instrument cables for flowswitches to annunciator panel The cable should be 2core x 1.5 Sq.mm copper armoured cable. Complete asper specification.

Rmt 4500

40

Supply, installation, testing and commissioning of waterflow will activate a hydraulic powered water motor alarmby way of integral valve alarm line trim piping. Watermotor gong shall be connected to a water pressureretarding chamber to limit the propensity of unnecessaryalarms. Water motor alarm shall be equipped with arear closure plate to limit the access of foreign materialsof accumulation of debris.Size of alarm valve shall be150NB.

No. 4

41

Steel supports for piping like clamps, tierods,brackets,nuts and bolts as per details given in the drawings.

kg 750

Page 47: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

HYDRANT SYSTEM PORTABLE FIRE EXTINGUISHERS:

34 Supply & installation of following Portable FireExtinguisher :

a ABC Type Extinguisher Nos. 96

Capacity - 5 KgType - UprightIS - 13849

b Carbon Dioxide Fire Extinguisher Nos. 49

Capacity - 4.5 KgType - UprightIS - 2878

c Foam Fire Extinguisher Nos 1

Capacity - 9 LitresType - Upright, Trolley mountedIS - 10204

d DCP Type Extinguisher Nos. 1

Capacity - 2 Kg

Type - UprightIS - 2171

Total C/o to Summary

Page 48: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

Item No.

Description of Item Unit Quantity Rate in figures (in

Rs.)

Rate in words (in Rs.) Amount (in Rs.)

J SEWAGE TREATMENT PLANT (MEMBRANETECHNOLOGY)SCHEDULE -1

A Supply, installation, testing, commissioning of SewageTreatment Plant (Excluding excavation, Back Filling &Disposal of surplus)

Job 1

Nature of Effluent - domestic Sewage from Toilet ,Kitchen waste water shall be discharged in to theSTP,Design to take consideration of same.Daily average flow Cum 60PH - 7.5 to 8.5BOD mg/ltr 450Suspended Solids mg/ltr 200COD mg/ltr 800Oil & Grease mg/ltr 50Effluent discharge standard after treatmentpH - 6.5 to 7.5BOD mg/ltr < 5Suspended Solids mg/ltr NilCOD mg/ltr < 10Oil & grease mg/ltr BDLTurbidity NTU < 4E coli Removal - Removal to the level of log 6Sewage treatment plant shall include the following items:

Grit chamberScreen ChamberOil & Grease TrapSewage equalization tank / sumpAeration cum MBR TankMembranesChemical Cleaning TankSludge Holding TankAir Blowers, Pumps & equipmentPiping, valves etcElectrical Panel & CablingSupply of Coarse Bar Screen

2 Supply, installation, testing & commissioning of 1 Nosfine Screen to remove the particle size above 3 mm withsuitable arrangement.

3 Supply, installation, testing & commissioning of electronictype level indicator and controller for automatic operationof the system with high/low level alarm complete withauxiliary NO / NC contacts for each tank.

4 Supply, installation, testing & commissioning of nonclogging type pumps capable of handling solids up to35mm having CI casing & SS impeller & Shaft completewith all accessories, motor of required capacity. Deliveryheader with isolation valve, pressure gauge on deliveryline with isolation cock, level controller (with wiring) tocontrol the level of sump automatically. Pumps shallhave following duty:

5 Submersible Sewage Pumps for transfer of Raw Sewagefrom EQT to Aeration Tank (1 working & 1 standby):-

Sludge disposal pump - (2 Nos - 1 working + 1 Standby)

Air diffusion system shall include the following:-Twin type rotary air blowers capable of deliveringrequired amount of free air at required pressure driventhrough “V” belt or directly coupled through flexiblecoupling to a TEFC motor of suitable HP Suitable for 415± 10% volts, 3 phase, 50 cycles A/C supply.The air blowers shall be of for the following purposes ofsuitable capacity :a) For Equalization and Aeration Tank (1 Working + 1Standby) b) For MBR Tank (1 Working + 1 Standby)

6 Air piping shall comprise of pipes droppers / laterals withMS (epoxy coated) Header complete with all fittings suchas tees, crosses, plugs, sockets, elbows,reducers,supports & clamps, puddle flanges etc cuttingchases & making good.

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHIPART-II (Non-Scheduled Items based on Market rates (STP)

Page 49: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

7 Non clog type air dispersion system capable of handling3- 5 cfm of air with oxygen transfer efficiency of 3-4% per/ meter water depth. Air dispersion grid shall beassembled in modular form so that they can be replaced/ repaired easily from plat form at the top. (Imported finebubble membrane diffusers).

8 Bronze Ball valve and air dispersion grid as required forSTP Note: Air dispersion system shall be provided forCollection Sump, aeration tanks and Sludge HoldingTank.

9 Providing and fixing all piping and isolation control valvesfor making the system complete SS 304: Submerged airpiping GI (HEAVY): Air piping & pumped effluent riser(nonsubmerged

10 Supply, installation, testing & commissioning of ChemicalCleaning system comprising suitable capacity ofChemical Cleaning tank filled with Sodium Hypochloriteand Citric Acid solution in required proportion andcentrifugal pump. The centrifugal pump shall be non clogwater pumps with CI Head & Base. (1 Working + 1Standby)

11 Supply, installation, testing and commissioning ofmembrane modules suitable for 60 KLD consisting of flatsheet / hollow fiber membranes housed in SS 304 /PVDF housing with SS 304 permeate water manifold andaeration diffuser system complete as required.

12 Supplying, installing, testing & commissioning ofhorizontal centrifugal non clog water pumps with CI Head& Base, SS Impeller of suitable capacities along withmotor, pressure gauge with isolation cock, Isolationvalve, NRV on delivery line. Isolation valve, strainer (withby-pass) at suction. Mechanical seal, suitable vibrationelimination pads of approved design, drain pipe withvalve (25 dia) for the pump. The pump shall be suitablefor 415±10% volts 3 phase AC supply (1 Working + 1Standby)

13 Membrane suction pump with VFD Nos. Membrane FeedPumps

14 Supply, installation, testing & commissioning of the PLCbased control panel with interlocking arrangement withsupply pumps, suction pumps, chemical cleaning tank,modulating or shut-off valves including necessary wiring,magnetic switches & sensors complete to make thesystem functional with following interlocking

a Suction pump stop-Supply pump stopb Suction pump's head loss greater then set suction head-

Suction pump stop & Chemical cleaning pump start

c Suction pump's head loss greater then set suction head-Suction pump's suction header valve stop

d Suction pump's head loss greater then set suction head-Chemical pumps delivery valve open in suction pump'ssuction header

15 Providing Of Prefabricated Skid Comprising of BioreactorTank , MBR Tank . LOT

SCHEDULE-2STP ELECTRICAL WORKSNOTES:-Contractor shall note that the quantities givenunder this schedule are "Provisional' and are subject toremeasurement upon completion for payment purpose.

Supply, Installation / Laying, Testing & Commissioning ofthe following:

B ELECTRICAL EQUIPMENTSPANEL

1 Design, fabrication, assembling, wiring,supply,installation, testing and commissioning of motorcontrol centre shall be fabricated out of 14 gauge CRCAsheet steel in form in 3b formation with reinforcement ofsuitable size angle iron, channel ‘T’ sections irons and/orflats wherever necessary. Cable gland plates shall beprovided on top as well as at the bottom of the panels.

Page 50: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

2 Panels shall be treated with all anticorrosive processbefore painting as per specifications with 2 coats of redoxide primer and final approved shade of powder coatedpaint. 2 No. earthing terminals shall be provided for 3phase, 4 wire, 50 Hz supply system. Lifting hooks shallalso be provided in case of large panels. Approval shallbe taken for each panel before fabrication. CadmiumPlated hardware shall be used in fabrication of panels.

3 Quoted rates shall inclusive of cables, cable trays (inaccordance to specification) with earthing from panel toeach motor / equipment.Incoming 1400 amps (25kA) TPN MCCB with the followingaccessories: 1

a 0-500 volts 96 x 96 mm square electronic voltmeter withselector switch shall be protected by 2 amps TP MCB. 1Set 1

b 0-400amps 96 x 96 mm square electronic ammeter withselector switch and 400./5 amps 10 VA CL:1 CTs. 1 Set1

c Phase indicating lamps shall be protected by 2 amp SPMCB 3 Set 1 Bus Bar 1 600 amps TPN (25 KA)aluminium bus bar with heat shrinkable insulationsleeves. 1

4 2 No. suitable rating MCB for 1.5 HP DOL starter andoutgoing feeder to EQT effluent transfer pumps motor(including 1nos. standby). Each compartment shallcontain auto / manual selector swtich and indicating /pushbutton lamps with MCB for ON / OFF / TRIP ofmotor. 1

5 2 No. suitable rating MCB for 3 HP direct on line starterand outgoing feeder to air blowers for Equalisation andAeration Tank (including 1 no. standby). Eachcompartment shall contain auto/manual selector switchand indicating lamps with MCB’s for ‘ON/OFF/TRIP'status of motor 1

6 2 No. suitable rating 4P MCB for 3 HP Star delta starterand outgoing feeder to air blowers for MBR Tank(including standby). Each compartment shall containauto/manual selector switch and indicating lamps withMCB’s for ‘ON/OFF/TRIP' status of motor 1

7 2 No. suitable rating 4P MCB for 1 HP DOL starter andoutgoing feeder to Sludge removal pumps motor(including 1No. standby). Each compartment shallcontain auto / manual selector swtich and indicating /pushbutton lamps with MCB for ON / OFF / TRIP ofmotor. 1

8 2 No. suitable rating 4P MCB for 1.0 HP direct on linestarter and outgoing feeder to Membrane Suction Pump(including standby). Each compartment shall containauto/manual selector switch and indicating lamps withMCB’s for ‘ON/OFF/TRIP' status of motor 1

9 2 No. suitable rating 4P MCB for 0.37 KW direct on linestarter and outgoing feeders to Chemical CleaningPump. Compartment shall contain auto / manual selectorswitch and indicating lamps with MCB’s for‘ON/OFF/TRIP’ status of motor. 1

10 2 Nos 4P MCB for 1.5HP direct on line starter and outgoing feeders to Sump Pump(including 1 no. standby).Each compartment shall contain direct operated (0-40) Aammeter with auto/manual selector switch and indicatinglamp with MCB’s for ‘ON/OFF/TRIP’ status ofmotor.status of motor.

11 1 No. 16 amps TPN MCCB outgoing feeder to AutomaticStep type bar screen. 1

12 1 No. 16 amps TPN MCCB outgoing feeder to AutomaticDrum type fine screen. 1

13 1 No. 16 amps TPN MCCB outgoing feeder to AutomaticScrew type Centrifuge. 1

14 Necessary cable alleys, internal wiring, andinterlocking,earthing for all equipment shall also included1 Spare of following capacities: 1i. 32 amps 4 Pole MCB 2 Nos. 1ii. 63 amps TPN MCCB 1 Nos. 1Notes:a. All MCCBs shall be of 25 KA breaking capacity b. All motor starter shall be provided with Automatic level

c. Provision shall be made for providing potential freeMCC-1 for STP as described above

Page 51: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

S.No. Description DSR Amount ( in Rs.) NSR AMOUNT (in Rs.)

1 Lifts and Escalator

2 Electrical Works 435,851.00

3 DG System 37,032.00

4 Solar System

5 HVAC WORKS

6 IBMS Works

TOTAL AMOUNT

MAIN ELECTRICAL WORKS

SUMMARY SHEET

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI

Page 52: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees

1

SOR Rate.Refer Part-153-External, Code:5.1.3

Design, supply, termination,testing and commissioning ofINDOOR type terminationkit and accessories suitablefor 11KV, 3 core 240 SqmmXLPE cable. ( 1set = RYBphase)

8 Each 4820 38560

2 SOR Rate 4.1MVET External

Supply & making endtermaination with brasscompression gland andaluminium lugs for followingsize of PVC insulated andPVC sheathed / XLPE Alconductor cable of 1.1 KVgrade as required.

a

DSR Rate. Refer Part-1-External, Page-81, Code:4.1.31

3.5 Core X 400 Sq.mm XLPEAluminium armoured Cable 26 Each 508 13208

b

DSR Rate. Refer Part-1-External, Page-80,

3.5 Core X 300 Sq.mm XLPEAluminium armoured Cable 4 Each 508 2032

c

DSR Rate. Refer Part-1-External, Page-79, Code:4.1.29

3.5 Core X 240 Sq.mm XLPEAluminium armoured Cable 2 Each 381 762

d

DSR Rate. Refer Part-1-External, Page-77, Code:4.1.27

3.5 Core X 185 Sq.mm XLPEAluminium armoured Cable 2 Each 319 638

e

DSR Rate. Refer Part-1-External, Page-76, Code:4.1.26

3.5 Core X 150 Sq.mm XLPEAluminium armoured Cable 6 Each 278 1668

f

DSR Rate. Refer Part-1-External, Page-75, Code:4.1.25

3.5 Core X 120 Sq.mm XLPEAluminium armoured Cable 4 Each 199 796

ELECTRICAL WORK

SOR Items

Page 53: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees SOR Items

g

DSR Rate. Refer Part-1-External, Page-74, Code:4.1.24

3.5 Core X 95 Sq.mm XLPEAluminium armoured Cable 4 Each 197 788

h

DSR Rate. Refer Part-1-External, Page-73, Code:4.1.23

3.5 Core X 70 Sq.mm XLPEAluminium armoured Cable 2 Each 168 336

i

DSR Rate. Refer Part-1-External, Page-72, Code:4.1.22

3.5 Core X 50 Sq.mm XLPEAluminium armoured Cable 2 Each 146 292

j

DSR Rate. Refer Part-1-External, Page-71, Code:4.1.21

3.5 Core X 35 Sq.mm XLPEAluminium armoured Cable 6 Each 137 822

k

DSR Rate. Refer Part-1-External, Page-84, Code:4.1.34

4 Core X 25 Sq.mm XLPEAluminium armoured Cable 110 Each 137 15070

3

DSR Rate. Refer Part-1-External, Page-83, Code:4.1.33

4 Core X 16 Sq.mm XLPEAluminium armoured Cable 90 Each 196 17640

4 SOR No. 3.6 EARCUPL

Earthing with copper earthplate 600mmx600mmx3mmthick including accessoriesand providing masonaryenclosure with cover platehaving locking arrangementand watering pipe etc. (butwithout charcoal or coke andsalt) as required

2 Each 3263 6526

5 SOR No. 3.8 EARCOKPL

Salt / coke for plte earthelectrode, extra for using saltand coke for GI or copperplate earth electrode asrequired.

2 Each 1484 2968

Page 54: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees SOR Items

6

SOR No. 3.2 EARPIPCHAR

GI earth pipe Electrode withsalt / charcoal earthing withGI earth pipe 4.5 meter long,40mm dia includingaccessories and providingmasonaries enclosure withcover plate having lockingarrangement and wateringpipe etc. with charcoal andsalt as required.

10 Each 1971 19710

7

SOR Rate. Refer Part-1-internal, Page-315, Code:3.9

Supply and laying of 8 gaugebare copper wire for Glandearthing, loop earthing in theexisting surface/recessedsteel conduit, DB earthingand other equipment bodyearthing as required.

500 R.M 41 20500

8 SOR NO.

2.72 DANPLHV

Providing and fixing HTdanger notice plate of250mmx200mm made ofmild stell atleast 2mm thickand vitreous enamelled whiteon both side and withinscrisption in single redcolor on front size asrequired

10 Each 75 750

9 SOR No. 2.71 DANPLMV

Providing and fixing MVdanger notice plate of200mmx150mm made ofmild stell atleast 2mm thickand vitreous enamelled whiteon both side and withinscrisption in single redcolor on front size asrequired

10 Each 68 680

10 SOR No. 1.24 MODSWEB Internal

Supply & fixing followingmodular switch / socket onexisting modular plate &switch box includingconnection but excludingmodular plate.

a 1.24.6 Telephone socket outlet 35 Each 61 2135

Page 55: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees SOR Items

11 SOR No. 1.27 MODGIBXCP

Supply & fixing following size/ modules GI box along withmodular base and coverplate for modular switches inrecess etc as required.

0

a 1.27.1 1 or 2 module (75mmx75mm) 35 Each 88 3080

12 SOR No. 1.20 STLCON

Supply & fixing of followingsize of steel conduit alongwith accessories in surface /recess including painting incase of surface conduit orcutting the wall and makinggood the same in case ofrecess conduit as required.

a 1.20.1 20mm 200 R.M 77 15400

b 1.20.2 25mm 250 R.M 86 21500

c 1.20.4 40mm 100 R.M 127 12700

d 1.20.5 50mm 100 R.M 168 16800

13 SOR No. 1.21 PVCCON

Supply & fixing of followingsize of PVC conduit alongwith accessories in surface /recess including painting incase of surface conduit orcutting the wall and makinggood the same in case ofrecess conduit as required.

a 1.21.1 20mm 800 R.M 41 32800

b 1.21.2 25mm 3000 R.M 47 141000

c 1.21.4 40mm 200 R.M 67 13400

d 1.21.5 50mm 100 R.M 90 9000

Page 56: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees SOR Items

14 SOR No. 1.31 LPACCMOD

Supply, fixing suitable sizeGI box with modular plateand cover in front on surfaceor in recess includingproviding and fixing 3 pin 5/6Amp modular socket outletand 5/6 Amp modular switchconnection, painting etc asrequired for UPS / RawPower Socket.

105 Each 160 16800

15 SOR No. 1.32 PPACCMOD

Supply, fixing suitable sizeGI box with modular plateand cover in front on surfaceor in recess includingproviding and fixing 6 pin15/16 Amp and 5/6 ampmodular socket outletand15/16 Amp modular switchconnection, painting etc asrequired for UPS / RawPower Socket.

35 Each 214 7490

TOTAL SOR ExternalAMOUNT 435851

1 SOR No. 3.6 EARCUPL

Earthing with copper earthplate 600mmx600mmx3mmthick including accessoriesand providing masonaryenclosure with cover platehaving locking arrangementand watering pipe etc. (butwithout charcoal or coke andsalt) as required

4 Each 3263 13052

2 SOR No. 3.8 EARCOKPL

Salt / coke for plte earthelectrode, extra for using saltand coke for GI or copperplate earth electrode asrequired.

4 Each 1484 5936

DG WORKS

Page 57: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

ITEM No.

SR REF. NO. Description of Item Qty Unit Rate in

Rupees Total Amount

in Rupees SOR Items

3

SOR No. 3.2 EARPIPCHAR

GI earth pipe Electrode withsalt / charcoal earthing withGI earth pipe 4.5 meter long,40mm dia includingaccessories and providingmasonaries enclosure withcover plate having lockingarrangement and wateringpipe etc. with charcoal andsalt as required.

4 Each 1971 7884

4.00 SOR No. 4.1 MVET

Supply and termination of thefollowing size cables withsuitable double compressionglands with suitable crimpingsocket.

a 3.5 Core X 400 Sq.mm PVCAluminium armoured Cable 20 Each 508 10160

DSR Amount of DGWORKS (Rs.)

37032

Page 58: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

I PASSANGER LIFT ( VVIP 1 AND 2 WITH LIFT NO 2,3,4 AND 5 )REFER DWG NO : DWG:NASC-AUD-AR07-01-01-141343 ,DWG:NASC-AUD-AR07-01-01-141345

1

Supplying, installation, testing & commissioning of 1360 kGS (20 Nos) capacity lift of machine room typeelevator standard design conforming to latest lift act andmodern lift with microprocesor including AC gearless-VVVF controller in the existing lift well / shaft havingminimum speed of 1 M/swith a total travel of 16.00(Appox.) mtrs. Basement, Ground Floor, First Floor andSecond floor 4 stops and 4 landings. on same side. Thelift shall be complete with SS Canvass Finish brightannealed finish stainless steel for car, car doors, landingdoors etc., (with all car interiors complete as perspecification)

6 Nos.

The lift shall be of excellent quality and shall have Microstroke push buttons, intelligent group controls of eight lifts,floor announcement system, Gearless and other featuresas per detailed specifications attached. The lift car shallhave two parallel car operating control panels in automaticmode (with or without attendant) and from one panel inattendant mode.

The lift equipment will be installed in the machine roomdirectly above the lift well. All the lift equipments, i/c car,car doors self-levelling devices, control devices,indicators, landing doors, indicators, buffer ropes safetydevices i/c all wiring connection, interconnection and allconnected equipments shall be as per specifications. Thework also includes all structural items in machine roomand above the lift well like RCC block, & MS girdersrequired for lift insallations & providing miscellaneousitems like supports for guide rails, overhead gears,scaffoldings, sill projections, facia inside the lift well, minorbuilding works like making sockets, holes etc. i/c makinggood the damages.

II PASSENGER LIFT ( LIFT NO :1)DWG:NASC-AUD-AR07-02-01-141344

1

Supplying, installation, testing & commissioning of1360kGS (20 Nos) capacity lift of machine room typeelevator standard design conforming to latest lift act andmodern lift with microprocesor including AC gearless-VVVF controller in the existing lift well / shaft havingminimum speed of 1.0m/sec with a total travel of 11.65(Appox.) mtrs. First Floor To Second floor 2 stops and 2landings. on same side. The lift shall be complete with SSCanvass Finish bright annealed finish stainless steel forcar, car doors, landing doors etc., (with all car interiorscomplete as per specification)

1 Nos

The lift shall be of excellent quality and shall have Microstroke push buttons, intelligent group controls of eight lifts,floor announcement system, Gearless and other featuresas per detailed specifications attached. The lift car shallhave two parallel car operating control panels in automaticmode (with or without attendant) and from one panel inattendant mode.

The lift equipment will be installed in the machine roomdirectly above the lift well. All the lift equipments, i/c car,car doors self-levelling devices, control devices,indicators, landing doors, indicators, buffer ropes safetydevices i/c all wiring connection, interconnection and allconnected equipments shall be as per specifications. Thework also includes all structural items in machine roomand above the lift well like RCC block, & MS girdersrequired for lift insallations & providing miscellaneousitems like supports for guide rails, overhead gears,scaffoldings, sill projections, facia inside the lift well, minorbuilding works like making sockets, holes etc. i/c makinggood the damages.

Amount in Rs.

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI PASSENGER LIFTS, SERVICE LIFTS AND ESCALATORS

(DESIGN, MANUFACTURE, SUPPLY, ERECTION, TESTING, COMMISSIONING INCLUDING MAINTENANCE)PRICED BILLS OF QUANTITIESAnnexure A (LIFTS & Escalator)

S.No. Description Qty Unit Rate

Page 59: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

The lift equipment will be installed in the machine roomdirectly above the lift well. All the lift equipments, i/c car,car doors self-levelling devices, control devices,indicators, landing doors, indicators, buffer ropes safetydevices i/c all wiring connection, interconnection and allconnected equipments shall be as per specifications. Thework also includes all structural items in machine roomand above the lift well like RCC block, & MS girdersrequired for lift insallations & providing miscellaneousitems like supports for guide rails, overhead gears,scaffoldings, sill projections, facia inside the lift well, minorbuilding works like making sockets, holes etc. i/c makinggood the damages.

III SERVICE LIFT ( LIFT NO 1)DWG:NASC-AUD-AR07-02-01-141344

1

Supplying, installation, testing & commissioning of 1360 kGS (22 Nos) capacity lift of machine room typeelevator design conforming to latest lift act and modernlift with microprocesor including AC-VVVF controller in theexisting lift well / shaft having minimum speed of 0.5m/sec with a total travel of 16.00 mtrs. Basement, Ground, Firstand Second floor, servicing 4 stops and 4 landings onsame side. The lift shall be complete with factoryenamelled / paint finish for car enclosure, ceiling & cardoors and landing doors shall be 16 G Vandal proofstainless steel door and handle inside the car. (with all carinteriors complete as per specification)

1 Nos

The lift shall be of excellent quality and shall have Microstroke push buttons, intelligent group of simplex controls,floor announcement system, Gearless machine and otherfeatures as per detailed specifications attached. The liftcar shall have car operating control panel (1no) inautomatic mode (with or without attendant) and from onepanel in attendant mode.

The lift equipment will be installed in the machine roomdirectly above the lift well. All the lift equipments, i/c car,car doors self-levelling devices, control devices,indicators, landing doors, indicators, buffer ropes safetydevices i/c all wiring connection, interconnection and allconnected equipments shall be as per specifications. Thework also includes all structural items in machine roomand above the lift well like RCC block, & MS girdersrequired for lift insallations & providing miscellaneousitems like supports for guide rails, overhead gears,scaffoldings, sill projections, facia inside the lift well, minorbuilding works like making sockets, holes etc. i/c makinggood the damages.

IV ESCALATORS ( 2 NOS )DWG:NASC-AUD-AR07-02-01-141344

1

Supply ,installation,testing and commissioning ofEscalator with Machine of capacity not less than 9000persons per hour and at a speed of a 0.5m/sec with aninclination of 35 Degree including all necessary ancillariesand accessories as specified in the Tender Documentand specification .It shall comply with all statutoryrequirement of the local Competent Authorities.

2 Nos

The above rates shall include approval / obtainingcompletion certificate from the electrical / lift inspectorateof Local Competent Electrical Authority / Lift Liecense forinstallation and commissioning of lifts before handing overthe entire installation of the lift.

Note: Vendors should give options for car Interiors. Thefinal specificfation shall be as per ICAR requirement.

TOTAL LIFT & ESCLATOR AMOUNT

SECTION - A :- Equipments - HT Panel Board,Transformers, HT cable & Busduct.

EXTERNAL ELECTRICAL WORKS

Page 60: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

For all items in section-A, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same. Note: Foundation for RMG, HT Outdoor Panel,Transformer, DG sets & Fuel tank etc will be in thescope of civil contractor

16            

Design,supply,Installation,Testing and Commissioning ofOUTDOOR Weather & Dust proof Type, floor mounting,free standing 11kV Ring Main Gear unit made out of M.Ssheet steel clad dust and vermin proof with 630A CopperBusbars, Interconnections, necessary protections,Measuring Instruments, Indicating Instruments, ProtectionRelays, CTs, PT with necessary control fuses/MCBs,Termination arrangements for Incoming and OutgoingCable of 11 kV 3Core 240 Sq mm XLPE Alu.Armouredearthed cable, Terminal Blocks, Earthing,Powder coatedpainting, Sign writing and Base channels etc., withcomplete all accessories as required for satisfactoryoperations and as per the detailed TechnicalSpecifications enclosed and as per EB Requirementscomprising of the followingINCOMER (2 Sources) :11kV, 630A, 500MVA LOAD Break Switch (Air Break )with necessary required accessories - 2NosOUTGOING :11kV, 630A, 500MVA VACCUM Circuit Breaker withnecessary required accessories : 1NoThe RMG panel shall be manufactured as required by theelectrical authorities and approval shall be obtainedincluding testing & commissioning and any additionalfeatures required by the supply authorities shall be carriedout at no extra cost

1 Each

17            

Supplying and spreading of 150mm sand cushion base,supplying and providing 300mm 40mm blue metal jellyand other associated works., earthing arrangement forfencing and gate complete as required by the CEA / CEIGregulation.

1 LS

18            

Design, supply, installation, testing and commissioning of11KV 630A, 500MVA, 26.2KA, Drawout type VCBBreaker HT Outdoor single Panel Board with allaccessories and all metering protection for satisfactoryoperation and as required by the statutory electricalauthorities as per the detailed specification enclosed.

1 Each

19            

Supplying and spreading of 150mm sand cushion base,supplying and providing 300mm 40mm blue metal jellyand other associated works., earthing arrangement forfencing and gate complete as required by the CEA / CEIGregulation.

1 LS

20            

Design, supply, installation, testing and commissioning of11KV 630A, 500MVA, 26.2KA, Drawout type VCBBreaker HT indoor single Panel Board with allaccessories and all metering protection for satisfactoryoperation and as required by the statutory electricalauthorities as per the detailed specification enclosed.

1 Each

21            

Design, supply, installation, testing and commissioning of1250KVA, 11 kV/433V outdoor, Dry type cast resinTransformer with ON load tap changer as per thedetailed specification enclosed. Transformer Protectionrelays should be provided at Transformer such asTransformer Buchholz relay, restricted earth faultrelay,winding temp relay, Auxiliary relays as perstandards. The transformer shall be provided with cabletermination box on HT side to terminate 3 core 240 SqmmXLPE cable and suitable for terminating air insulatedcopper busduct on LT side 4000A Amps rating all as perthe detailed specification enclosed.

1 Each

Page 61: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

22            

Supplying and spreading of 150mm sand cushion base,supplying and providing 300mm 40mm blue metal jellyand other associated works., earthing arrangement forfencing and gate complete as required by the CEA / CEIGregulation.

1 LS

23            

Design, supply, laying, testing and commissioning of 3 core 240 sqmm (E) 11KV, HT XLPE Aluminiumconductor individual core screened, flat steel striparmoured, PVC sheathed cable inside the building intrench with exacavation and proper filling, sand cushioningand brick protection as per specification(From 11KV RMGto 11KV outdoor HT single panel, 11KV indoor HT panel,Transformer)

300 R.M

24            

Design, supply, erection, testing and commissioning of2000 Amps INDOOR TYPE 4 Pole Sandwich Copperbusduct with flexible joints at every 4.5Mtr. Interval(RYBN) with suitable support as per the detailedspecification enclosed. The busduct should be withstraight run, 90 deg. Horizontal and vertical bends., busbartrunking fittings (elbow, tees, end End (Cable) feed Box,end covers, horizontal fixing devices,etc.)

The busduct shall run from Transformer secondary toMPCC Panel. Horizontal runs of busbar trunking systemshall be supported by hangers at every 2 metre. Verticalruns of busbar trunking system shall be supported byhangers not more than 4m apart. Busbar trunking system shall be terminated by ‘endcaps(closure)’. The bus duct shall be fabricated as per the detailed specification enclosed. Current Density ofbusbars shall not exceed 1.2 Amps/ Sq.mm.The rate shallbe inclusive of steel support with painting and all othernecessary accessories

10 R.M

25            

Design, supply, erection, testing and commissioning of1250 Amps INDOOR TYPE 4 Pole Sandwich Copperbusduct with flexible joints at every 4.5Mtr. Interval(RYBN) with suitable support as per the detailedspecification enclosed. The busduct should be withstraight run, 90 deg. Horizontal and vertical bends., busbartrunking fittings (elbow, tees, end End (Cable) feed Box,end covers, horizontal fixing devices,etc.)

The busduct shall run from MPCC Panel to APFCR panel.Horizontal runs of busbar trunking system shall besupported by hangers at every 2 metre. Vertical runs ofbusbar trunking system shall be supported by hangers notmore than 4m apart. Busbar trunking system shall be terminated by ‘endcaps(closure)’. The bus duct shall be fabricated as per the detailed specification enclosed. Current Density ofbusbars shall not exceed 1.2 Amps/ Sq.mm.The rate shallbe inclusive of steel support with painting and all othernecessary accessories

8 R.M

26            

Design, supply, erection, testing and commissioning of2000 Amps Phase cross changeover box suitable forsandwich copper bus duct including all accessories.

1 Each

27            

Design, supply, erection, testing and commissioning of1250 Amps Phase cross changeover box suitable forsandwich copper bus duct including all accessories.

1 Each

28            

Design, supply, erection, testing and commissioning ofBattery Charger 110V DC 100 AH Trip unit combinedwith trickle & boost charge facilities with battery bank(SMF) & Distribuition Board and as per the detailedspecification/drawing enclosed.

1 Each

Page 62: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

29            

Providing, 9" Brick wall below FFL 500mm and above FFL300mm with double side plastring and 2.1 mtr heightweldmesh fencing with vertical angle iron supports( withRCC) spaced as per standards, hinged lockable door foreach yard as required, painting with red oxide andaluminium paint as required, suitable necessary civilfoundation, necessary anlge iron support and earthingarrangment complete as required by the CEA / CEIGregulation for RMG, HT outdoor panel, DG Yard etc. Therate shall inclusive of providing necessary gates withsuitable tubular supports.

100 Sq.Mtr

30            

Soil Excavation of site 600mm x 600mm x 1500mm (Maximum ) for construction of inspection pit, constructionof brick masonary pit of side 600mm x 600mm x 375mmincluding plastering and providing RCC Frame with RCCPrecast slab provided with Edge beading

20 Each

31            

Soil Excavation of site 1200mm x 600mm x 1500mm (Maximum ) for construction of inspection pit, constructionof brick masonary pit of side 600mm x 600mm x 375mmincluding plastering and providing RCC Frame with RCCPrecast slab provided with Edge beading

2 Each

32            

Supply and laying of the following size RCC hume pipeswith collar including excavation to a depth of 750mm to1000mm from existing ground level, back filling, rampingthe soil, making the surface to match the original surfaceas required.

a100 mm dia (Class "NP2")

100 R.M

b200 mm dia (Class "NP2")

100 R.M

c300 mm dia (Class "NP3")

100 R.M

Section-B: MPCC & Sub LT PanelsFor all items in section-B, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.

33            

Design, supply, erection, testing and commissioning ofcubicle type floor mounting main power control centremade out of MS sheet enclosure with Copper busbars,single busbar system, cable chamber, interconnection,painting, earthing, protection relays etc. comprising of thefollowing : (MPCC)INCOMINGEB Incomer1 No. 2000 Amps 4 Pole 65KA electrical draw out typeAir circuit breaker with shunt release shutter assembly,door interlock and all other accessories.

Instruments Panel Digital type Ammeter with selector switch, Voltmeter withselctor switch, Maximum demand controller,Instantaneous earthfault relay (2 O/C+ 1 E/F), Low setearth fault relay (51G), CTs control fuses, RYB Indicationlamps and “ON/OFF/Trip" indicating lamp in eachincomer, and also refer the drawing.

DG Incomer1 No. 2000 Amps 4 Pole 65KA electrical draw out typeAir circuit breaker with shunt release shutter assembly,door interlock and all other accessories. Instruments Panel Digital type Ammeter with selector switch, Voltmeter withselctor switch, CTs control fuses, RYB Indication lampsand “ON/OFF/Trip" indicating lamp in each incomer, andalso refer the drawing.Buscoupler

Page 63: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

1No.2000 Amps 4 pole 65KA electrical draw out type Aircircuit breaker with shunt release, shutter assembly, doorinterlock and all other required necessary accessories andON/OFF lamps.The buscoupler shall be provided with mechanical &electrical Inetrlocking arrangements.OUTGOINGS1250A 4P EDO ACB, 50 KA – 1No800A 4P EO MCCB, 50 KA – 3Nos630A 4P EO MCCB, 50 KA – 2Nos400A 4P EO MCCB, 50 KA – 10Nos

All the Outgoing feeder should be ON/OFF/Trip indicationlamps, Digital type Multifuction meter(Except capacitorfeeder which is provided with Ammeter), CTs,Fuse, Switchcontrol,Front operting handles etc. All switch boards shallbe fabricated as per the detailed specification enclosed.Suitable size outgoing cable chamber and extra busbarsshould be provided for connecting the number of outgoingcables as per the schematic drawing. The board shall befabricated for future extension of the panel board.

The transformers incomer shall be provided withprotection relays such as IDMT (2 O/C +1 E/F), Maximumdemand controller, REFR (Restricted Earth faultRelay),etc., and bus coupler shall be both mechanical andelectrical interlocking arrangements by hardware controlwiring alongwith PLC (Programmable Logic Controls). TheHardware control wiring & PLC operation shall be feasibleto extend for future Transformer if any and all as per thedetailed specification and drawings enclosed. -

This incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.Main Power Control Centre (MPCC)2000Amps TPN Copper busbars:- All the neutralbusbars shall have half the capacity of phasebusbars.(1.2A/Sq. mm.)

1 Each

34            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (APFCR Panel)Incoming1250A TP&N MDO ACB 65 KA Drawout type with Autopower factor correction relay with necessary CT, controlwiring etc.- 1 No. as incomer. Outgoing: Total 425 KVAR2 sets of 100 KVAR (4 x 25 KVAR) with 400A TP MCCB,suitable contactors with switching steps in the rating of100 KVAR as required.3 sets of 50 KVAR (2 x 25 KVAR) with 200A TP MCCB,suitable contactors with switching steps in the rating of 50KVAR as required.3 sets of 25 KVAR (1 x 25 KVAR) with 100A TP MCCB,suitable contactors with switching steps in the rating of 25KVAR as required.Each All KVAR capacitor bank in a separate compartmentwith necessary ventilation arrangemnts or weld mesharrangements as required by the Electrical Authorities .

With necessary copper busbars, interconnections,providing Ammeter with selector switches, phaseindication lamp, control fuse and switch control, PF meteretc. as per the specification.Capacitor Panel - 425 kVAR1250 Amps TPN Copper busbars:- All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm)

1 Each

35            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (HVAC & Ventilation Panel)

INCOMING630A TPN MCCB 35 KA with connected accessories –1No.as incomer

Page 64: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

OUTGOINGS200A TPN MCCB, 16 KA – 3Nos100A TPN MCCB, 16 KA – 5NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.HVAC & VENTILATION PANEL630A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

36            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (AHU Panel-1,2,3)INCOMING100A TPN MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS32A TPN MCCB, 16 KA – 8NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.AHU PANEL-1,2,3100A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

3 Each

37            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Ventilation Panel-1)INCOMING200A TPN MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 8Nos32A TPN MCCB, 16 KA – 2NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.VENTILATION PANEL-1200A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

38            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Ventilation Panel-2)

INCOMING200A TPN MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 4Nos32A TPN MCCB, 16 KA – 8NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.

The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.

VENTILATION PANEL-2

Page 65: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

200A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

39            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Main Lighting Panel)INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS250A TPN MCCB, 25 KA – 5Nos

With necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.

The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.

MAIN LIGHTING PANEL400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

40            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Sub Lighting Panel-1,2)

INCOMING250A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS32A TPN MCCB, 25 KA – 10Nos

With necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.

The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.

SUB LIGHTING PANEL-1,2250A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

2 Each

41            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Sub Lighting Panel-3)

INCOMING250A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS32A TPN MCCB, 25 KA – 6Nos

With necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.

The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.

SUB LIGHTING PANEL-3250A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

Page 66: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

42            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Main Power Panel)INCOMING800A TPN MCCB 50 KA with connected accessories –1No.as incomer OUTGOINGS400A TPN MCCB, 35 KA – 6NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.MAIN POWER PANEL800A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

43            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Sub Power Panel-1)

INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 20NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.SUB POWER PANEL-1400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

44            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Sub Power Panel-2)INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 14NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.SUB POWER PANEL-2400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

45            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Sub Power Panel-3)INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 12NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.

Page 67: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.SUB POWER PANEL-3400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

46            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (UPS incoming Panel)

INCOMING250A TPN MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS125A TPN MCCB, 25 KA – 2Nos63A TPN MCCB, 16 KA – 1NoWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.UPS INCOMING PANEL250A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

47            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (UPS Outgoing Panel)

INCOMING125A TP+2N MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 8NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.UPS OUTGOING PANEL125A Amps TP+2N copper busbars : All the neutralbusbars shall have double the capacity of phasebusbars (1.2A/Sq. mm.).

1 Each

48            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Emergency Lighting Panel)

INCOMING100A TPN MCCB 25 KA with connected accessories –1No.as incomer OUTGOINGS32A TPN MCCB, 16 KA – 12NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.EMERGENCY LIGHTING PANEL100A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

Page 68: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

49            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Utility Panel)INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS63A TPN MCCB, 16 KA – 3Nos32A TPN MCCB, 16 KA – 7NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.UTILITY PANEL400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

50            

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Lift Panel)INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS32A TPN MCCB, 16 KA – 16NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.LIFT PANEL400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

1 Each

SECTION – C : DISTRIBUTION BOARDSFor all items in section-C, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.LIGHTING DISTRIBUTION BOARDS (LDBs) & POWERDISTRIBUTION BOARDS (PDBs)

51            Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4wayMCCB DB comprising of the following :

40 A FP MCCB – 1No. as incomer.25A DP MCB (C-Curve) with 25A DP ELCB 30mA – 3Nos. as outgoings.Each 25A DP MCB outgoing consist of 4nos.10A 10KASPMCB (C-Curve) in a separate compartment withnecessary phase segregation as required by the ElectricalInspectorate.

With necessary tinned copper busbars, interconnections,separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed withconcealed system in wall. The rate shall includenecessary connected civil works like chipping, roughplastering etc.

12 Each

52            Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8wayMCCB DB comprising of the following :

63A FP MCCB – 1No. as incomer.63A DP MCB (C-Curve) with 63A DP ELCB 30mA – 3Nos. as outgoings.

Page 69: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Each 63A DP MCB outgoing consist of 8nos.10A 10KASPMCB (C-Curve) in a separate compartment withnecessary phase segregation as required by the ElectricalInspectorate.

With necessary tinned copper busbars, interconnections,separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed withconcealed system in wall. The rate shall includenecessary connected civil works like chipping, roughplastering etc.

34 Each

EXTERNAL LDB for Street lighting (Vertical TPN DB)

53            Supply, fixing, testing and commissioning of the double door type VTPN 4way MCCB DB comprising of thefollowing :

125A 4P MCCB 25KA with ELM and all other requiredaccessories – 1 No. as incomer with timer & contactor.

32A 4P MCB 10KA – 4 Nos. as outgoings.

With necessary tinned copper busbars, interconnections,earth bus, neutral bus. The board shall be powder coatedtype fixed with concealed system in wall. The rate shallinclude necessary connected civil works like chipping,rough plastering etc.

1 Each

54             UPS DB (7 segment DB)

Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8wayMCCB DB comprising of the following :

63 A TP+2N MCCB – 1 No. as incomer.63A DP RCBO Type-A with D-Curve 30mA – 3 Nos. asoutgoings.Each 63A DP RCBO outgoing consist of 8nos.6/16A 10KA SPMCB (D-Curve) in a separate compartment withnecessary phase segregation as required by the ElectricalInspectorate.

With necessary tinned copper busbars, interconnections,separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed withconcealed system in wall. The rate shall includenecessary connected civil works like chipping, roughplastering etc.

4 Each

55            Supply, fixing, testing and commissioning of the double door type VTPN 4way MCCB DB comprising of thefollowing :

40 A 4P MCCB 25KA with ELM and all other requiredaccessories – 1 No. as incomer 16/20A 4P MCB 10KA – 4 Nos. as outgoings.

With necessary tinned copper busbars, interconnections,earth bus, neutral bus. The board shall be powder coatedtype fixed with concealed system in wall. The rate shallinclude necessary connected civil works like chipping,rough plastering etc.

2 Each

56            Supply, fixing, testing and commissioning of the double door type VTPN 8way MCCB DB comprising of thefollowing :63A 4P MCCB 25KA with ELM and all other requiredaccessories – 1 No. as incomer 16/20A 4P MCB 10KA – 8 Nos. as outgoings.

With necessary tinned copper busbars, interconnections,earth bus, neutral bus. The board shall be powder coatedtype fixed with concealed system in wall. The rate shallinclude necessary connected civil works like chipping,rough plastering etc.

15 Each

SECTION – D : WIRING AND CONNECTED ACCESSORIES

Page 70: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

For all items in section-D, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.

Note : ALL POINT WIRING FOR LIGHT / FAN / PLUGPOINTS SHALL INCLUDE COST OF CIRCUIT MAINS.NO EXTRA PAYMENT WILL BE MADE FOR THE SAME.

57.00      

Wiring to the light points /6A plug point using 3 X 1.5sqmm multi strand PVC insulated copper conductor(FRLS) with ROHS compliant in suitable size GI pipe inopen system in above false ceiling and concealed systemin below false ceiling on wall/column etc. The rate shouldinclusive of supply and fixing of 6A modular type switch ina suitable size modular box etc.

a One light controlled by one switch 115 Point

b Two light controlled by one switch 210 Point

c Three light controlled by one switch 160 Point

d Four light controlled by one switch 20 Point

e Five light controlled by one switch 4 Point

f 6A socket controlled by 1no 6A switch 30 Point

58            

Wiring to the exhaust fan points using 2 X 2.5 sqmm and1 X 1.5 sqmm multi strand PVC insulated copperconductor (FRLS) with ROHS compliant in suitable size GIpipe in open system in above false ceiling and concealedsystem in below false ceiling on wall/column etc. The rateshould inclusive of supply and fixing of 6A modular typeswitch in a suitable size modular box etc. (Average lengthof point - 12 mtr)

10 Point

59            

Wiring to the 6/16A 5Pin or 6Amps UPS/Raw powersocket using 2 X 2.5 sqmm and 1 X 1.5 sqmm multistrand PVC insulated copper conductor (FRLS) withROHS compliant in suitable size GI pipe in open systemabove false ceiling and concealed system in below falseceiling in wall / column etc.

5000 R.M

60            

Supply, fixing, testing and commissioning of 1No. 16/20Amodular socket for UPS or Raw Power supply and switch combination in a suitable size modular box inrecessed system. (16/20A socket controlled by 1 Switch)

5 Each

61            Design, supply and fixing of 20A 3 pin metal clad socketwith 20A DP MCB in a suitable size MS enclosure fixed inrecessed system. (Mancooler)

10 Each

62            Wiring to the power plugs using 3 Runs of 4 sq.mm pvcinsulated (FRLS) armoured copper cable in wall /column etc. (for 20A metal clad socket with 20A DP MCB)

1000 R.M

Page 71: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

63            

Supply and laying of following size PVC/GI conduits infloor / wall /ceiling etc. including necessarybends,elbow,etc, in concealed system below the falseceiling on wall/floor and open system on above falseceiling.(for Telephone/Data cabling etc.)

64            

Supply and laying of following runs of PVC insulatedcopper conductor (FRLS) with ROHS compliant in existingfloor trunking. The rate shall be inclusive of civil workssuch as chipping, plastering with chicken mesh andfinished to match with the original surface.

a 1 X 1.5 Sq.mm copper conductor 200 R.M

b 1 X 2.5 Sqmm copper conductor 200 R.M

c 2 X 2.5 Sqmm copper conductor 250 R.M

d 3 X 2.5 Sq.mm copper conductor 500 R.M

e 3 Core X 2.5 Sq.mm copper conductor 300 R.M

f 3 Core X 4.0 Sq.mm copper conductor 300 R.M

65            

Supply, fixing of the 100 x 45 mm aluminium Channel(Raceways) including stiffner at required intervals inrecessed system in floor including cutting chippling,plastering in the floor/wall to make good finish to matchwith the floor /wall etc. (Thickness: 2mm for Top & Baseand 1.6mm for sides)

250 R.M

66            

Supply, fixing of the 50x 25 mm aluminium Channel(Raceways) including stiffner at required intervals inrecessed system in floor including cutting chippling,plastering in the floor/wall to make good finish to matchwith the floor /wall etc. (Thickness: 2mm for Top & Baseand 1.6mm for sides)

100 R.M

67            

Supply, fixing of the 300 x 40 mm aluminium Channel(Raceways) including stiffner at required intervals inrecessed system in floor including cutting chipping,plastering in the floor/wall to make good finish to matchwith the floor /wall etc. (Thickness: 2mm for Top & Baseand 1.6mm for sides)

20 R.M

68            

Supply fixing of the 150 x 150 x 50 mm floor junction boxwith necessary civil works fixed in recessed system infloor including cutting chippling, plastering in the floor/wallto make good finish to match with the floor/ wall etc.

5 Each

69            

Supply fixing of the 250 x 250 x 50 mm floor junction boxwith necessary civil works fixed in recessed system infloor including cutting chippling, plastering in the floor/wallto make good finish to match with the floor/ wall etc.

15 Each

70            

Supply fixing of the 350 x 350 x 50 mm floor junction boxwith necessary civil works fixed in recessed system infloor including cutting chippling, plastering in the floor/wallto make good finish to match with the floor/ wall etc.

10 Each

Page 72: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

71             Supply and fixing of RJ45 Data socket with suitablemodular plate and metal box. 35 Each

72             Supply and fixing of Wi-fi point 35 Each

73            Supply and fixing of floor boxes 10 modules similar toLegrand Mosaic cat.no 089620 or equivalent with allaccessories and the following combination.

2Nos.6/16A Raw power socket controlled by 1No.Switch

2Nos.6/16A UPS power socket controlled by 1No.Switch

1No.Data socket and 1No.Voice socket 105 Each

SECTION – E : CABLES AND TERMINATIONFor all items in section-D, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.

74            

Supply, laying of following size XLPE (FRLS) insulatedouter sheathed (1100 V grade) aluminium / copper,armoured / unarmoured conductor cable (with ROHS compliance if any) partly laid in existing cable tray andpartly laid in wall/ ceiling with suitbale clamps. Cable traywill be measured and paid separately.

a 3.5 Core X 400 Sq.mm XLPE Aluminium armoured Cable 1500 R.M

b 3.5 Core X 300 Sq.mm XLPE Aluminium armoured Cable 200 R.M

c 3.5 Core X 240 Sq.mm XLPE Aluminium armoured Cable 50 R.M

d 3.5 Core X 185 Sq.mm XLPE Aluminium armoured Cable 50 R.M

e 3.5 Core X 150 Sq.mm XLPE Aluminium armoured Cable 200 R.M

f 3.5 Core X 120 Sq.mm XLPE Aluminium armoured Cable 300 R.M

g 3.5 Core X 95 Sq.mm XLPE Aluminium armoured Cable 200 R.M

h 3.5 Core X 70 Sq.mm XLPE Aluminium armoured Cable 100 R.M

i 3.5 Core X 50 Sq.mm XLPE Aluminium armoured Cable 100 R.M

j 3.5 Core X 35 Sq.mm XLPE Aluminium armoured Cable 100 R.M

k 4 Core X 25 Sq.mm XLPE Aluminium armoured Cable 3500 R.M

Page 73: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

l 4 Core X 16 Sq.mm XLPE Aluminium armoured Cable 4000 R.M

m 4 Core X 10 Sq.mm XLPE Copper armoured Cable 50 R.M

n 4 Core X 6 Sq.mm XLPE Copper armoured Cable 50 R.M

o 4 Core X 4 Sq.mm XLPE Copper armoured Cable 50 R.M

p 4 Core X 2.5 Sq.mm XLPE Copper armoured Cable 50 R.M

q 1 Core 25 Sq.mm XLPE Copper armoured Cable 50 R.M

r 24 Core X 2.5 Sq.mm XLPE Copper armoured Cable 50 R.M

s 12 Core X 2.5 Sq.mm XLPE Copper armoured Cable 50 R.M

75            

Supply and termination of the following size cables withsuitable double compression glands with suitable crimpingsocket. (copper sockets for copper cables and Alu.Sockets for alum. Cable)

a 4 Core X 10 Sq.mm PVC Copper armoured Cable 4 Each

b. 4 Core X 6 Sq.mm PVC Copper armoured Cable 4 Each

c 4 Core X 4 Sq.mm PVC Copper armoured Cable 4 Each

d 4 Core X 2.5 Sq.mm PVC Copper armoured Cable 4 Each

e 1 Core 25 Sq.mm PVC Copper Unarmoured Cable 4 Each

f 24 Core X 2.5 Sq.mm PVC Copper Unarmoured Cable 4 Each

g 12 Core X 2.5 Sq.mm PVC Copper Unarmoured Cable 4 Each

76             50 x 10mm Copper flat for Transformer Neutral. The jointsshall be provided with Rivet/ bracing 30 R.M

77             50 x 6mm Copper flat for DG Neutral. The joints shall beprovided with Rivet/ bracing 50 R.M

SECTION - F

Page 74: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

78             40 x 6 mm Copper flat for Transformer body and HT panelbody. The joints shall be provided with Rivet / bracing 100 R.M

79             25 x 6mm Copper flat for Subpanels. The joints shall beprovided with Rivet/ bracing 150 R.M

80             25 x 3mm Copper flat for Subpanels. The joints shall beprovided with Rivet/ bracing 250 R.M

81             Design, cutting, and fixing of 9mm thick chequered platewith required MS angles. 20 Sq.mtr

82            

Supply and Installation of MS flat / angle iron supports forvarious purpose if required with various sizes includingcutting,welding,grinding,fixing accessories and one coat ofprimer & two coats of enamel paints, minor civil works etc.as required.(Note: The flat / angle iron weight will bearrived on the basis of theoretical calculation only).

10 MT

SECTION – G : CABLE TRAYS

83            Supply, erection of following sizes GI ladder / perforatedtype cable rack system made out of sheet steel folded torequired shape with adequate number of supports.

The cable rack shall have runners rugs of suitable size,horizontal elbow, vertical elbow 90 Deg. Up vertical elbow90 Deg. Down, re-deep, coupler plates, materials.Thecable racks shall be suspended from ceiling supportedfrom side walls in columns etc. with adequate sizesupporting angles / channels with fastners, welding,anchor bolts, nuts etc. The rack shall have suitable cableclamping arrangements etc. The metal rack system shallbe treated with one coat of rubber based polyvinyl paint asprimer and finished with two coats of green enamel paintcomplete with all civil works for fabrication details. Referenclosed drawing.

The rate shall be inclusive of thread rod/gripple/steelsupport with one coat of primer & two coats of enamelpaints and all accesories to fix the hangers atpurlin,rafter,beam,wall and ceiling with requiredclamps,anchor fastener,nuts & bolts to be considered.Thissupport spacing and fixing as per standards. The height of the hanging arrangement shall be as per drawing.

83.1         Perforated type

a 75mm x 40mm x 2.0 mm 100 R.M

b 100mm x 50mm x 2.0mm 100 R.M

c 150mm x 50mm x 2.0mm 150 R.M

d 300mm x 75mm x 2.5mm 200 R.M

Page 75: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

e 450mm x 75mm x 2.5mm 100 R.M

f 600mm x 75mm x 2.5mm 200 R.M

g 750mm x 75mm x 2.5mm 150 R.M

h 1000mm x 75mm x 2.5mm 150 R.M

83.2         Laddertype

a 600mm x 75mm x 2.5mm 200 R.M

b 750mm x 75mm x 2.5mm 200 R.M

c 1000 mm x 75mm x 2.5mm 200 R.M

SECTION – H : Safety Equipments

84             Supply and laying of 20mm thick 1000mm wide chequeredrubber mat with ISI mark suitable for 11KV installation . 10 Sq.mtr

85             Supply and laying of 12mm thick 1000mm wide chequeredrubber mat with ISI mark suitable for 440V installation . 40 Sq.mtr

86             Supply and fixing of HT/LT cable route indicator made outof MS flat and angle iron. 60 Each

87            Supply and providing first aid box 18SWG MS sheet dulypainted as approved by Indian red cross soceity completewith all first aid medicines.

2 Each

88            Supply and providing shock treatment chart in English,Hindi duly framed with 2mm thick glass in front & 6mmthick ply on backas required

2 Each

89             Supply of tested hand gloves of 11KV grade. 4 Each

90            

Supply and fixing of GI fire buckets with round bottom,each set comprising 4Nos.fire buckets of 9Kg capacityincluding supply of M.S pedestal stand with hooks suitablefor holding of 4Nos of fire buckets, painted with PostOffice Red oil paint and letter FIRE on each bucket andfilling with sand complete as required

2 Each

91             Supply and erection of fire extinguisher Co2 4.5 Kg.confirm to IS norms. 10 Each

Page 76: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

92             Supply & Fixing of Artificial Respirator for Inspiration withchart showing the use of it. 2 Each

SECTION - I : LIGHTNING PROTECTION SYSTEMFor all items in section-H, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.

93            

Supply,Installation,Testing and commissioning of theAdvanced Lightning Protection Stormaster ESE AirTerminal with all accessories required for its properfunctioning. The elevated pole should be fitted firmlyattached to the wall or coloumn with suitable guy wiresystem as per manufacturer recommendations to beprovided.

1 Each

94            

Supply,Installation,Testing and commissioning of theHVSC down conductor shall be consists of copperconducors, inner insulation, outer copper conductor,conductive sheaths, all cencentrically arrangements outerdiameterr of the down conductor shall be less than 37mm.The main conductor cross sectional area is 50 sq.mm Thedown conductor shall be placed minimum wall thicknessand minimum bending radius is 0.5m.The down conductor50 sq.mm / 37mm / OD weight is 2.050 kg per Meter withall fastening with tape clip etc.

160 Each

95            

Supply,Installation,Testing and commissioning of theLightning Strike Recorder designed for easy mountingon the down conductor to effectively count the number ofliightning strikes captured by the air terminal. The recordersensitive range of 1500 amps to a maximum of 220KA @8/20µs. The recorder is self powered and does not requirethe use of battery or any other external power source etc.

1 Each

96            

Supply,Installation,Testing and commissioning of efficientearthing system with copper bonded earth rod, Clamp,Copper Tape, Ground Resistance Improvement powder allas required including excavation of earth etc as requiredas per manufacture recommendation.

1 Each

SECTION – J : External WorksFor all items in section-I, the rate includes necessaryconnected minor civil works if required and necessarysupports as required at site. No extra payment will bemade for the same.

97             PHILIPS Alpha Power with AC 1x24 CREE XPG OREquivalent Supply and erection of IP65 LED SOLAR streetlightLuminaire of not more than 21W (System wattage)complete with pressure die cast aluminum housing alsoadhering to the specifications attached

10 Each

98             PHILIPS CPP 745 OR Equivalent Leonardo decorative post top lantern made of die castaluminium housing with high corrosion resistance withhigh finish extruded aluminium column with base flangeand IP55 protection for dust and jet proofing

2 Each

Lamp: 1 x SON 70W

99             PHILIPS CPP 735

Regina Indirect light decorative post top lantern made ofdie cast aluminium housing of canopy with high corrosionresistance with high finish extruded aluminium column withbase flange and IP65 protection for dust and jet proofingalongwith extruded aluminium pole and suitable for metalhalide lamp

2 Each

Page 77: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Lamp: 1 x CDM-T 70W

SECTION – K : Miscellaneous

100         

Supply, Installation, Testing and commissioning of the 30kVA UPS system 3 phase input and three phase outputand as per the detailed specification enclosed.(Forcomputers & other essential loads) including

Supply, Installation, Testing and Commissioning of SealedMaintenance Free Batteries to support 30KVA for 15minutes complete with intercell connectors & coppercables, battery stand made out of Powder Coated MSAngles with adequate supports to carry the load of thebatteries.The vendor shall submit dimensional GA drawing ofcomplete UPS system, battery rack with batteries,Service bypass Panel and Battery bank calculationsalong with offer.

1 Each

101         

Supply, Installation, Testing and commissioning of the 20kVA UPS system 3 phase input and three phase outputand as per the detailed specification enclosed.(ForEmergency Lighting) including Supply, Installation, Testing and Commissioning of SealedMaintenance Free Batteries to support 20KVA for 15minutes complete with intercell connectors & coppercables, battery stand made out of Powder Coated MSAngles with adequate supports to carry the load of thebatteries.The vendor shall submit dimensional GA drawing ofcomplete UPS system, battery rack with batteries,Service bypass Panel and Battery bank calculationsalong with offer.

1 Each

102         

Towards professional charges for filing application,Liasioning with state Electricity Board for getting the threephase HT/LT connection, follow up with State electricityboard, getting the load sanction, load release letter,commissioning the installation. The rate shall includesarranging inspection (if required) at site.

1 LS

103         

Towards professional charges for preparation of drawingsin necessary formats for approval, follow up and arrangingapproval of drawings, scheme by Local electricity authority/ Electrical Inspectorate, arranging inspection, obtainingsafety certificate clearance from electrical Inspectorate forthe installation and arranging power connection. The Rateshall be including preparation and submission of as builtdrawings of entire installation of the works executed needto be submitted in the blue print of A1 size as required in 6Sets of hard copy and two set sets of soft copy in CD.

1 LS

TOTAL MARKET AMOUNT

DG WORKS

Page 78: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

5.00

Design, Manufacture, Transportation, Supply, Installation,Testing and Commissioning of factory assembled andfactory tested, water cooled, turbo charged after cooleddiesel engine alternator set capable of generating full loadof minimum 625 KVA DG set, 1500 rpm, four stroke, withacoustic enclosure, designed for operating on HSD, 415V,50 Hz, 0.8 pf, complete with all accessories, like baseframe, residential silencer, radiator, alternator capable ofdelivering 415 Volts, 50Hz, 3 phase, PF 0.8, 625 KVAload (minimum), coupling arrangement of alternator withengine, coupling guard, water pump, oil pump, fuel filter,oil filter, air filter, exhaust flexible piping, fuel tank of 990litres, fuel transfer hand pump with suitable hose pipebatteries 24V and 200 AH capacity, battery chargingalternator, engine control panel, anti-vibration mountingsuitable for starting of the DG Set with standard controlpanel and includes the following transport, insurance,handling, safe keeping at site etc., erection, installation,testing and commissioning including performance tests asper Specifications. The necessary foundation will beprovided by other agency.

2 Each

6.00

Supply,Installation, Testing and Commissioning of AMFwith Auto Synchronising control panel with Auto Loadsharing arrangement of indoor, floor mounting type with 2Nos. 1000Amps, TP, 50KA, EDO type, air circuit breakerwith shunt release, shutter assembly, door interlock andother required accessories and 400Amps,4 pole, neutralisolating contactor as incoming with complete set ofinstrument panel with accessories, protectionrelease/relays etc. and 1No. 2000Amps, 4Pole, 65KA,EDO type, air circuit breaker with shunt release, shutterassembly, door interlock and other required accessoriesas outgoing feeders with complete set of instrument panelwith accessories, protection release/relays etc.

1 Each

7.00

Supply and Laying of 40mm x 6mm copper flat from earthelectrode in 40mm dia B class GI, directly in groundincluding earth work excavation, refilling the trench, withall accessories, jointing the flats with lap joint with 2Nos.of bolt/nuts/spring washers/check nuts completed etc. asrequired.(For Netural earthing)

200 R.M

8.00 Supply and laying of No 8 SWG (4.0mm dia) copper wireon surface or in recess for loop earthing etc. as required. 50 R.M

9.00

Supply and Laying of 25mm x 3mm copper flat on surfaceor in recess for generator body earthing, jointing the flatswith lap joint with 2Nos. of bolt/nuts/spring washers/checknuts completed etc. as required.(For Body earthing &ligtning spike)

150 R.M

10.00

Supply and fixing of 8" dia MS exhaust pipe class Bsuitable for 625 KVA engine exhaust line including withall accessories such as bends,.flanges, gaskets,condensation removal plug, fixing of flexible coupling,residential silencer supplied along with the engine.Providing necessary MS angle iron supports for the pipeline and the silencer, welding arrangements/ flanged jointswith bolts/nuts as per the site conditions. Terminating thepipe line/ ducting in scrubber and chimney including thecomplete pipe line/ duct of insulation with 50mm thickglass wool, polythene covering,chicken mesh andaluminium cladding complete as per the specificationsetc. as required.

20 R.M

11.00 Supply and fixing of 12" dia MS exhaust pipe class B 40 R.M

12.00

Supply & fixing of 50mm thick glass wool insulation for the625KVA engine residential silencer including cutting, fixingof glass wool, chicken mesh and aluminium claddingcomplete as per the specifications etc. as required.

2 Each

Page 79: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

13.00

Supply & fixing of 50mm thick glass wool insulation for 8"dia MS exhaust pipe class B including cutting, fixing ofglass wool, chicken mesh and aluminium claddingcomplete as per the specifications etc. as required.

40 R.M

14.00

Supply & fixing of 50mm thick glass wool insulation for 12"dia MS exhaust pipe class B including cutting, fixing ofglass wool, chicken mesh and aluminium claddingcomplete as per the specifications etc. as required.

60 R.M

15.00

Supply and laying of 25mm dia , B class MS pipe, fuel linefor the interconnection of the reserve tanks to day tankand day tank to engine i/c. fuel transfer pumps with allaccessories such as bend,elbow, coupling, union,plugs,flanges,bolts/nuts,gaskets, making threadedends/welding as per the site condition laying in thefollowing manner etc. as required.

a In the exposed surface the pipe line shall be painted withone coat of primer and two coats of synthetic enamel painti/c. with necessary supports complete as required.

30 R.M

b

In soil , below 0.5 Mtrs from the ground level , the pipeline shall be painted with one coat of hotbitumen,wrapping with 3 layers of hessian cloth dipped inhot bitumen i/c. with necessary supports complete etc. asrequired.

30 R.M

16.00

Supply and fixing the following size of valves in theexisting 25mm dia MS pipe line i/c. cutting,threding,welding,grinding, fixing,painting etc. as required(ISI marked make)

a 25mm dia brass gun metal Ball valve 2 Each

b 25mm dia brass gun metal NRV valve 2 Each

17.00

Supply and fixing of outdoor fuel day tank made up of MSsheet, 990 ltrs capacity i/c. cutting,welding,grinding,providing inlet,outlet, overflow, drain, airvent, inlet fuel filter, fuel level indicator with scale, fuellevel switch for level monitoring through IBMS, painting,fixing with suitable size MS angle iron frame work on theexisting foundation etc. as required. (Excluding cost offoundation).

2 Each

18.00

Supply, laying of following size XLPE (FRLS) / PVC(FRLS) insulated outer sheathed (1100 V grade)Aluminium / Copper armoured conductor (with ROHS compliance if any) cable partly laid in existing cable trayand partly laid in wall/ ceiling with suitbale clamps. Cabletray will be measured and paid separately.

a 3.5 Core X 400 Sq.mm PVC Aluminium XLPE armoredCable laying through trench (trench will be made by otheragency)

200 R.M

b 16 Core X 2.5Sq.mm PVC sheated XLPE Copperarmoured Cable 100 R.M

c 4 Core X 2.5 Sq.mm PVC sheated XLPE Copperarmoured Cable 200 R.M

d 6 Core X 2.5 Sq.mm PVC sheated XLPE Copperarmoured Cable 150 R.M

e 24 Core X 2.5 Sq.mm PVC sheated XLPE Copperarmoured Cable 100 R.M

Page 80: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

f 4 Core X 4 Sq.mm PVC sheated XLPE Copper armouredCable 100 R.M

19.00

Supply and termination of the following size cables withsuitable double compression glands with suitable crimpingsocket. (Copper sockets for Copper cables andAluminium Sockets for Aluminium Cable)

b 16 Core X 2.5Sq.mm PVC Copper armoured Cable 4 Each

c 4 Core X 2.5 Sq.mm PVC Copper armoured Cable 4 Each

d 6 Core X 2.5 Sq.mm PVC Copper armoured Cable 4 Each

e 24 Core X 2.5 Sq.mm PVC Copper armoured Cable 4 Each

f 4 Core X 4 Sq.mm PVC Copper armoured Cable 4 Each

20.00

Design, supply and fixing of copper lightning spike at the top of the stack with suitable supports.

2 Each

21.00

Design, Manufacture, Supply and Fixing G.I flanges ofapproved make with IRI washers including making holes,fixing in position to threaded ends of pipes using MS bolts,nuts and washers etc. and testing as per IS specificationand as directed.

1 Each

22.00 Supply and Providing of following items.

a

Fuel unloading hand pump.

1 Each

b

PVC Hose - 10 mtrs.

10 R.M

Total AMOUNT OF DG WORKS

Design , supply, erection, testing and commisioning of100Kwp solar hybrid power pack system complete with allaccessories. (Refer Technical specification for details) 1 Job

TOTAL AMOUNT OF SOLAR WORKS

A WATER COOLED SCREW CHILLERS

1

Supply, customs clearance, freight up to site,Insurance, delivery, hoisting, installing, testing andcommissioning the following items as shown on theequipment data and drawing for complete andsatisfactory operation and control and to localauthorities approval

HVAC WORKS

SOLAR WORKS

Page 81: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Supplying, installation, testing and commissioning ofWATER COOLED SCREW CHILLER complete withscrew compressors, motor, water cooled condenser,insulated chiller, flow switch at chiller and condenser,vibration isolators, integral refrigerant piping and wiring,accessories as required and called for, automatic andsafety controls mounted in central console panel and allmounted on a steel frame etc. Motor shall be suitable forIndian Conditions and operating on 415±10% 50 cycles. 3phase AC supply. Chiller for air conditioning system shallbe selected on the basis of New Delhi ambient condition.Refrigerant used shall be Ozone friendly HFC R134a asper specifications. Chillers capacity of each chilling unitwill be as follows:

Chiller Capacity : 190 TR (actual capacity)Evaporator Side:Water in : (+) 12 Deg CWater Out : (+) 7 Deg CFouling factor : 0.0001 FPS unitsCondenser Side:Water in : (+) 32 Deg CWater Out : (+) 36 Deg CFouling factor : 0.00025 FPS units Nos. 3

2Necessary sockets and nipples with suitable brass thermowell for mounting sensors / transmitters on pipe line tointerface the BMS system.

Lot 3

Total carry over to summary (Chillers)

B CHILLED WATER AND CONDENSER WATER PUMPS

1

To design, supply, installation, testing andcommissioning of the following items as shown onthe equipment data and drawings for complete andsatisfactory operation and control and to localauthorities approval.

Energy efficient, BAS interfacing type, End Suction LongCoupled Base Mounted chilled water circulation pumpsethaving required capacity against the selected head withC.I. casing, bronze impeller mechanical seal, Internal Self-flushing type, stainless steel shaft sleeve, integral motorscomplete with Factory made weather cowl, acoustic box,drive guard, 25x25x3 mm thick nosing angle frame floatingfountation with spring isolator as per specification.

All pumps shall be factory aligned. The pump motor shallbe suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10%combined voltage and frequency variation, 3 phase ACpower supply. The quoted price shall include cost ofthermal insulation and Aluminium cladding and requiredlength of power cable from the starter panel. Motor shallbe TEFC – Class F and temperature rise restrict to ClassB insulation IP55 protection and Minimum pump hydraulicefficiency shall be 75%

Primary Vary Flow Chilled water pumps Type : End Suction Centrifugal PumpsFlow : 456 USGPMTemp range: (-)5Deg C upto 45 Deg CTotal Head: 35 MtrCondenser water pumps (Constant flow)Type : End Suction Centrifugal PumpsFlow : 650 USGPMTemp range: (-)5Deg C upto 45 Deg CTotal Head: 20 Mtr

a Nos.

b Nos. 3

3

Page 82: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

2

Design, supply, Fabrication, installation, testing andcommissioning of Pump Logic Control Panel consists ofVariable speed drives (Frequency controller and autobypass) VFD panels for the above primary vary flowchilled water pump sets complete with necessary pressuresensors/transmitters/ temperature sensor/flowmeter/switch, Microprocessor based pump logic controller,suitably integrated with adjustable frequency drive in asingle enclosure and capable to control necessary AFD formultiple pump sets. Parallel pump software dulydownloaded and integrated with pump system. VFDpanels shall be supplied with mounting frames and powerwires / control wiring between pump motor, AFD andpump logic controller. The integrated power cabling andcontrol wiring between adjustable frequency driver andlogic controller panel and for sensor shall be included inthe cost.

CHW pump 3 VFD - 2 Working + 1 Standby Lot 1

Pump design parameter furnished in the BOQ and inthe specification is of indicative in nature. If the actualparameter required to meet the proposed primary varyflow chilled water system and constant flowcondenser water system, then the same shall beprovided by AC Contractor based on the finalselection without any cost implication to the Owner. Total carry over to summary (Chilled water,Condenser water pumps)

C COOLING TOWER

1

Supplying, installing, testing and commissioning of CrossFlow or counterflow, Induced Draft, Vertical DischargeType, Single / Multicell, FRP Cooling Tower complete withmotor, fan, other complete accessories as described in thetechnical specifications. It shall be designed with highefficiency drift eliminator. Each tower cell must beinstalled with individual cold water basins and waterdischarge sumps to facilitate maintenance without causingdisruption to the other cells in operation. All pipingconnections to the disribution basin should be made ofsteel and not from PVC. Vibration Isolators of spring opentype designed to minimise any vibration from transmittingto other structures to be included in the scope of supply.Motors shall be suitable for 415 + 10%volt, 50 cycles3phase power supply. Isolators at cooling tower enclosedin weather proof panel shall also be included. Tower forair conditioning system shall be selected on the basis ofNew Delhi ambient condition and the Tower shall be CTIcertified.Chiller Capacity : 190 TR Cooling tower Capacity : 240 TR (min)Water Flow Rate : 650 USGPMWater Temp In : 36 o CWater Temp Out : 32 o CTotal carry over to summary (Cooling tower)

Nos. 3

D AIR HANDLING UNITS & TFA UNITS1 AIR HANDLING UNITS - FLOOR MOUNTED TYPE

Page 83: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Supply, installation, testing and commissioning of DoubleSkin Air Handling Units of Horizontal / VerticalConfiguration (suitable to the available AHU room), filtersection, Chilled water coil, Electric Strip Heaters, Fansection, High efficiency motor, Low leak volume controldamper, Flexible connections, Aluminium base framecomplete as per specifications as required. All sheet metalcabinet type air handler complete with coil section withcooling coil of 6 row or 8 row deep (copper tube andaluminium fins construction), fan section with centrifugalfans motor belt drive, belt guard, vibration isolators,thermostat, humidistat, canvass connections and withcontrol panel as per specification and cabling from panelto motors etc.

The price quoted shall also include the following.a) All internal wiring, power cabling, copper earthling ofair handling unit motors, from the local control panel andcontrol wiring b) Bimetallic lugs shall be used at copper to aluminiumjoints.c) special acoustic treatment to achieve the desire noiseleveld) Accessories and associated wiring between firedamper panel to fire damper and AHU motor to close firedampers and shut-off AHU motor in the case of fire. wiringbetween marine light and limit switch.AHU Specifications:Cooling Capacity : 38.0 TRDehumidified air quantity : 21500 CFMElectric Strip Heaters : 15 kW x 3 NosFan Ex. static pressure : 1.5 Inch.WgMax motor rating : 15 kWCooling Capacity : .38.0 TRDehumidified air quantity : 15950 CFMElectric Strip Heaters : 15 kW x 3 NosFan Ex. static pressure : 1.5 Inch.WgMax motor rating : 11 kWCooling Capacity : .27.0 TRDehumidified air quantity : 10500 CFMElectric Strip Heaters : 10 kW x 3 NosFan Ex. static pressure : 1.0 Inch.WgMax motor rating : 7.5 kWCooling Capacity : .27.0 TRDehumidified air quantity : 9000 CFMElectric Strip Heaters : 10 kW x 3 NosFan Ex. static pressure : 1.0 Inch.WgMax motor rating : 5.5 kWCooling Capacity : 34.0 TRDehumidified air quantity : 20600 CFMElectric Strip Heaters : 14 kW x 3 NosFan Ex. static pressure : 1.5 Inch.WgMax motor rating : 15 kWCooling Capacity : 30.0 TRDehumidified air quantity : 14750 CFMElectric Strip Heaters : 9 kW x 3 NosFan Ex. static pressure : 1.25 Inch.WgMax motor rating : 11 kWCooling Capacity : 30.0 TRDehumidified air quantity : 17150 CFMElectric Strip Heaters : 8 kW x 3 NosFan Ex. static pressure : 1.5 Inch.WgMax motor rating : 11 kWCooling Capacity : 30.0 TRDehumidified air quantity : 15550 CFMElectric Strip Heaters : 8 kW x 3 NosFan Ex. static pressure : 1.5 Inch.WgMax motor rating : 11 kWCooling Capacity : 20.0 TRDehumidified air quantity : 10050 CFMElectric Strip Heaters : 2.5 kW x 3 NosFan Ex. static pressure : 1.0 Inch.WgMax motor rating : 7.5 kW

h Nos.

i Nos.

e Nos.

f Nos.

g Nos.

Nos.

c Nos.

d Nos.

a Nos.

b

1

1

1

2

2

1

1

1

1

Page 84: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Cooling Capacity : 20.0 TR Dehumidified air quantity : 8750 CFMElectric Strip Heaters : 2.5 kW x 3 NosFan Ex. static pressure : 1.0 Inch.WgMax motor rating : 5.5 kW

Some other Specifications: (Common for all AHUs)

Design apparatus dew point - 12 Deg CChilled water entry temperature - 7 Deg CChilled water leaving temperature - 12 Deg CChilled water Flow - 2.4 GPM per TRFilter SectionMERV 8 FILTERS DURING CONSTRUCTION AND PRE-COMMISSIONING MERV 13 FILTERS AFTER COMMISSIONING

2 Ceiling Suspended Type AHU's

Double Skin Ceiling Suspended AHU with 6 Row coolingcoils (copper tubes with aluminium fins construction),filters sections, medium pressure fan section withcentrifugal fan/s, sq.cage induction motor belt drive, beltguard, vibration isolators, double canvas connections andwith unit mounted emergency off station internally factorywired between motors and emergency off station as perspecifications.

AHU Specifications: Cooling Capacity : 10.0 TR

Dehumidified air quantity : 4800 CFM

Cooling Capacity : 7.5 TR

Dehumidified air quantity : 4550 CFM

Some other Specifications: (Common for all AHUs)

Design apparatus dew point - 12 Deg CChilled water entry temperature - 7 Deg CChilled water leaving temperature - 12 Deg CChilled water Flow - 2.4 GPM per TRFilter SectionMERV 8 FILTERS DURING CONSTRUCTION AND PRE-COMMISSIONING MERV 13 FILTERS AFTER COMMISSIONING

3

Supply & Installation of Stater Panel with VFD as detailedin the technical specification. Cost of Panel with Starterwith VFD should be considered by AHU Manafacturer andit should be noted that Starter panel should be housed onthe external surface of AHU and TFA. The Communicationcard to transfer the entire data available on VFD to theBMS System. VFD shall be Danfoss VLT 6000 Series /ABB ACH 550

a 15 kW Nos 3

b 11 kW Nos 5

c 7.5 kW Nos 2

d 5.5 kW Nos 2

4 FAN COIL UNITS

a Nos.

b Nos.

j Nos.

2

1

1

Page 85: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Supplying, installing, testing and commissioning ofVertical or Horizontal version powder coated fan coilunits, draw through type, each complete with necessaryrows deep chilled water coils, one or more centrifugalfans, tropicalised motors with self lubricating bearingsaluminium / synthetic cleanable filters, primary andsecondary condensate drain pans duly with nitrile rubberinsulated, (to eliminate the eventuality of choked fan coilunit drains)casing, coil piping connections through copperpipes, condensate drain connection, multi core copperpower wiring, control wiring, in conduit up to thethermostat boxes & MS boxes for thermostat inclusive of 3way control valve (Siemens or equivalent make),Thermostat with cooling and 3-speed motor. The springruturn type control valve bypasses the chilled water whenthe unit is not in operation to avoid condensation.

a Cooling Capacity: 4TR, Air Quantity: 1600cfm Nos 1

b Cooling Capacity: 3TR, Air Quantity: 1200cfm Nos 1

c Cooling Capacity: 2TR, Air Quantity: 800cfm Nos 1

5 TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEELSSupply,installation, testing and commissioning of Centralised Treated Fresh air unit consists of exhaust air block and fresh air block. Each block is made up of double skin construction designed on modular concept basis and has for fans, motors, VFDs for fan motors, chilled water coil, damper and filter. Each block module shall be fitted with other block, housing heat recovery devices, washable metallic viscous filters (50mm thick) and inlet and outlet dampers (extruded aluminium low leakage construction) with bird screen for supply and return air.Air flow parameters: Heat Recovery wheel to recover energy complete with desiccant coated aluminium media rotor seal GI structural frame work to house rotor, drive system, rotor drive motor, belt, pre-filter complete with starter panel. The TFA shall have Thermal Break Profile.The price quoted for Treated fresh air unit shall include the following a) All internal wiring, power cabling copper earthing of treated fresh air unit motors, from the panel and control wiring b) Bimetallic lugs shall be used at copper to aluminium j i t d ifi tiCoil size shall be eight row coil selected for a maximum face velocity of 2.75 mps and external static pressure shall be minimum 500pa.The vendor shall be select the suitable units with minimum leakage. The fresh air quantity required after leakage is as follows.

a Cooling Capacity: 21TR, Air Quantity: 9900cfm Nos 1

b Cooling Capacity: 19TR, Air Quantity: 9300cfm Nos 1

c Cooling Capacity: 17TR, Air Quantity: 7900cfm Nos 1

d Cooling Capacity: 15TR, Air Quantity: 7300cfm Nos 1

Some other Specifications: (Common for all AHUs)

Page 86: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Design apparatus dew point - 12 Deg CChilled water entry temperature - 7 Deg CChilled water leaving temperature - 12 Deg CFan Ex. static pressure - 1.5 Inch.WgFilter SectionMERV 8 FILTERS DURING CONSTRUCTION AND PRE-COMMISSIONING MERV 13 FILTERS AFTER COMMISSIONING

6

Supply & Installation of Stater Panel with VFD as detailedin the technical specification. Cost of Panel with Starterwith VFD should be considered by AHU Manafacturer andit should be noted that Starter panel should be housed onthe external surface of AHU and TFA. The Communicationcard to transfer the entire data available on VFD to theBMS System. VFD shall be Danfoss VLT 6000 Series /ABB ACH 550

a 7.5 kW Nos 4

b 5.5 kW Nos 4

7

Supply, installation, testing and commissioning DigitalInverter - Wall mounted split Unit Capacity of 2.0TR. TheIndoor unit shall comprise of Blowers, Cooling coil, Filterand Expansion device and drain pan. The Outdoor unitshall comprise of digital Inverter Compressor, Air cooledcondenser & Condenser fans. Rate inclusive of requiredlength copper piping with 13mm thick nitrile rubberinsulation, voltage, stabilizer, refrigerant charging, powercable from the panel/isolator, control cable, wirelessremote controller, supports for indoor and outdoor units,etc.

Nos 1

E PIPES AND VALVES

1

Supply, erection, testing and commissioning of chilledwater / Condenser water pipes. Pipes will be of MS ClassC’ up to 150mm dia as per IS 1239, 6 mm thick for 200mmand 250mm dia pipes and 8mm thick above 300mm dia as per IS 3589. Necessary RCC pedestals of required sizesshall be provided at every 2200mm interval to run thepiping above the floor level by ACMV contractor. Rateshall inclusive of necessary fittings like bends, elbows,Tee, etc

All other pipe supports will have to be on regular pipehangers with spring and acceptable isolation in eachsupport. The quoted piping rate shall include forincorporating service flanges on all valves, strainers,service screen/basket strainer on the water line entry to allequipments like chilled water coils and chillers serviceflanges, descaling Tees, airvent valves, drain valves etc.,required to make the circuits fully operational. Thetemporary service strainers shall be removed anddiscarded after the first few hours of trial runs.

a 250 NB - 6mm thick Rmt 87

b 200 NB - 6mm thick Rmt 667

c 150 NB - MS Class C Rmt 30

d 125 NB - MS Class C Rmt 151

Page 87: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

e 100 NB - MS Class C Rmt 57

f 80 NB - MS Class C Rmt 100

g 65 NB - MS Class C Rmt 169

h 50 NB - MS Class C Rmt 187

i 40 NB - MS Class C Rmt 42

j 32 NB - MS Class C Rmt 60

k 25 NB - MS Class C Rmt 62

2

Providing and fixing in position the following GI Class Bpipe cut to required length and installed with all screwjoints, reducer, necessary elbows and tees, supportingarrangements, etc.

a 50 NB Rmt 123

b 32 NB Rmt 63

c 25 NB Rmt 70

3

Supply and erction of Thermal insulation of chilled waterpiping with closed cell nitrile rubber insulation. Insulationthickness shall be 25mm for pipes upto 65mm dia and32mm insulation for pipes above 65mm dia

a 200 NB Rmt 39

b 150 NB Rmt 30

c 125 NB Rmt 151

d 100 NB Rmt 57

e 80 NB Rmt 100

f 65 NB Rmt 158

g 50 NB Rmt 178

h 40 NB Rmt 42

Page 88: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

i 32 NB Rmt 49

j 25 NB Rmt 63

4

Supply and erction of Thermal insulation of chilled waterpiping with TF quality of density 24 Kg/Cu.Mtr. EPS withGI wire and covered with polyethylene sheet as vapourbarrier. Two coats (each 6 mm thick) of cement plastershall be applied over chicken wire mesh lath as per thespecifications

200 NB Rmt 623

5

Supply, installation, testing and commissioning of flexible connections of suitable pressure rating to be installed atpump suction, discharge and at pipes crossing buildingexpansion joints.

a 200 NB Nos. 18

b 150 NB Nos. 12

c 80 NB Nos. 4

d 65NB Nos. 16

e 50NB Nos. 12

f 40NB Nos. 2

g 32NB Nos. 6

h 25NB Nos. 4

6

Providing and fixing in position the following Butterfly valves (PN16) complete with end flanges/matchingflanges, additional supports, fixing accessories, thermalinsulation etc. as per specification.

a 200 NB - Gear driven Nos. 18

b 150 NB - Lever operated Nos. 12

c 125 NB - Lever operated Nos. 8

Page 89: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

d 80 NB - Lever operated Nos. 4

e 65 NB - Lever operated Nos. 19

f 50 NB - Lever operated Nos. 20

7Providing and fixing in position the following Ball valvescomplete with end flanges/matching flanges, additionalsupports, fixing accessories etc. as per specification.

a 40 NB - Lever operated Nos. 2

b 32 NB - Lever operated Nos. 8

c 25 NB - Lever operated Nos. 21

8

Supply and erection of Double plate Check valves withcast iron body Gr 220 ASTM A217 Gr-CA15, plate SS316springs, SS410 hinges/Stop pin and AISI SS316 bearings,matching flanges / Buna or rubber seal to ANSI 125 seal,thermal insulation etc.

a 200 NB Nos. 3

b 150 NB Nos. 3

c 50 NB Nos. 2

9

Supply and erection of Intelligent balancing valves, non-rising spindle of stainless steel SS410 stem, stainlesssteel disc of AISI SS410 with EPDM sealing on seat,double seal by EPDM back flow and graphic asbestospacking on spindle C1220 cast iron / aluminium / MSfabricated hand wheel with pressure test cocks formeasurements and regulation of flow through pressuredrop across the valves, thermal insulation as specified,flanges boards, drain valves etc. suitable forcomputerized balancing instrumentation probes.

a 200 NB Nos. 9

b 150 NB Nos 3

c 125 NB Nos 4

Page 90: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

d 80 NB Nos 2

e 65 NB Nos 8

f 50 NB Nos 6

g 40 NB Nos 1

h 32 NB Nos 2

10

Supply and erection of MS fabricated ‘Y’ type strainerwith removable brass / stainless steel (SS-316) screen(24G) with 3mm perforation and permanent magnet, drainpiping(SS-410) complete with matching flanges andthermal insulation as specified

a 80 NB Nos. 2

b 65 NB Nos. 8

c 50 NB Nos. 6

d 40 NB Nos. 1

e 32 NB Nos 2

11

Supply and erection of Ball Valve with Strainer. Valveshall be bronze forged body construction with chromeplated bronze ball and handle of stainless steelconstructions complete with matching flanges and thermalinsulation as specified

a 32 NB Nos. 1

b 25 NB Nos. 2

12

Supply,installation, testing and commissioning of Two waymotorised Valves (ON/OFF Type) provided with springreturn function in chilled water lines at chillers andcondenser water line at cooling towers. The actuator of themotorized valve shall have required torque to ON/Off theactuator with 220 V / 24 V transformer duly encased andwired. The motorised valve & actuator shall be compatibleto third party intergration and necessarry communicationcables, hardware, convertor, etc shall be included. Thevalves shall be suitable for following pipe sizes

Page 91: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

a 200 NB Nos. 6

b 150 NB Nos. 3

13

Supply,installation, testing and commissioning of Two waymotorised Valves (Modulating Type) provided with springreturn function in chilled water lines at AHUs. The actuatorof the motorized valve shall have required torque toON/Off and modudate the actuator with 220 V / 24 Vtransformer duly encased and wired. The motorised valve& actuator shall be compatible to third party intergrationand necessarry communication cables, hardware,convertor, etc shall be included. The valves shall besuitable for following pipe sizes

a 150 NB Nos. 1

b 80 NB Nos. 2

c 65 NB Nos. 8

d 50 NB Nos. 6

e 40 NB Nos. 1

f 32 NB Nos. 2

14

Supply, installation, testing & commissioning of Closed expansion tank as per standards & requirements.Capacity 1000 Ltrs. Tank shall be complete with 0.5 HPPumps required in the configuration of 1 working + 1Stand By. The cost shall include necessary valve package& control logic panel for pump automation

Sets 1

15Supply and erection of Water Dial Type Pressure gauges complete with ball valve, gauge valve mounting, fittingsand copper tubing extension where required

Nos. 66

16

Supply and erection of Dial Type Thermometers withcopper separable well complete with guard mounted onwater lines, thermo wells, etc., in the inlet and outlet ofcooling coil connections.

Nos. 52

17

Supply and erection of probe type flow meter to measurethe flow in CHW pipe line. The flow meter shall beprovided with necessary fittings & electronic digital readout.

Nos 1

18 Supply and erection of Temperature sensors withnecessary fittings & electronic digital read out. Nos 2

19

Supply and erection of Automatic Air Vents shall beinstalled at all high sections of piping. The discharge fromthis air vents shall be piped via tubes of appropriate sizeto the nearest waste drain pipe.

Nos. 33

F AIR DISTRIBUTION SYSTEM

Page 92: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

1

Supply, installation, testing and balancing of AirDistribution System consists of factory fabricated sheetmetal ducting complete with supports (anchor fastners andtie-rods, cradles, angle iron supports, GI bolts and nuts,4mm thick self-adhesive neoprene rubber gasket,stiffeners, zinc chromate painted angle iron flanges,chipping and plastering of openings made for ductsupports etc., filling the gap with fibre glass wool and withfire sealant complete as per specification. The ratesquoted shall include turning vanes, straightening vanes,splitters, inspection doors probe, inlets with test openingsenclosures complete with locking caps, chain, gaskets,insulating plugs, and extension for insulated ductwork etc.

a 1.2mm thick GSS (18G) ducting – factory fabricated Sq.m. 182

b 1.0mm thick GSS ducting (20G) – factory fabricated Sq.m. 102

c 0.8mm thick GSS ducting (22G) – factory fabricated Sq.m. 2028

d 0.63mm thick GSS ducting (24G) – factory fabricated Sq.m. 4775

2

Supply and installing of Accoustic insulation, Materialshall be processed Nitrile Rubber foam with MICROBANhaving anti-microbial protection. The material should befibre free. The density of the same shall be within 140-180Kg/m3.The material should have a thermal conductivitynot exceeding 0.038 W/mK. The maximum surfacetemperature the material should withstand is 105º C andminimum temperature should be -20ºC. The Thickness ofthe material shall be 15mm. The material should conformto Class 1 rating for surface spread of Flame as per BS476 Part 7.

Sq.m. 1318

3

Supply and erection of Thermal Insulation of Supply airduct with 9mm thick closed cell nitrile rubber temperaturerange from -10ºC to +60ºC, Class O fire category and asper specification.

Sq.m. 4521

4

Supply and installation of AHU room acoustic lining onwalls/mechanical plant room with 50 mm thick fibre glassand 48 Kg/Cum density with GI frame grid and coveredwith 22G perforated GI sheet as per the approved shopdrawings & specifications.

Sqm 1282

5

Flexible duct connections between main duct and diffuserplenums shall be 25mm thick fiber glass pre-insulated,single ply / multiply Aluminium construction and withmultiple layers of polyester film glass fiber covered withmechanical lock sheets/ Aluminium laminated jackets-Fireresistant complete with Pre-fabricated and powder coatedAluminium angle frame mounting brackets and supportsand clamping for the both ends

a 300mm dia Rmt 66

b 250mm dia Rmt 432

6

Supply and fixing of Spigot damper shall be installedfrom take off collar to diffuser plelum boxes and at plenumboxes (low leakage) made out of 1.6mm galvanized sheetsteel frame and blades of 1.0mm galvanized steel withsuitable links.

Page 93: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

a 300mm dia Nos. 44

b 250mm dia Nos. 288

7

Supply and fixing of Extruded Aluminium, powder coatedSupply air diffusers with removable centre core overallsize 600 x 600mm without volume control dampers. Therate shall inclusive of Pre-fabricated Acoustic insulatedplenum boxes for supply air diffusers with 12mm thickopen cell nitrile rubber lining inside the plenum box. Theplenum box shall be supported at the four corners withhanger / chain support.

a 375 x 375mm neck size Nos 44

b 300 x 300mm neck size Nos 288

8Supply and fixing of Extruded Aluminium, powder Coatedreturn air diffusers with removable centre core overallsize 600 x 600mm without volume control dampers.

Nos 350

9

Supply and installation of Powder coated extrudedaluminium continuous linear 2 way grilles with 15 degreedeflection with jet nozzles and volume control damper forsupply air for auditorium as per drawing & specifications

Sq.m. 7

10

Supply and installation of Powder coated extrudedaluminium continuous linear 2 way grilles with 15 degreedeflection with volume control damper for supply air asper specifications

Sq.m. 19

11

Supply and installation of Powder coated extrudedaluminium continuous linear grilles with 0 degreedeflection without volume control damper for return air asper specifications.

Sq.m. 35

12

Supply and installation of Powder coated extrudedaluminium Circular diffuder with jet nozzles and volumecontrol damper for supply air as per specifications. Dia600mm

Nos 40

13Supply and installation of Powder coated extrudedaluminium Circular Diffusers without volume controldamper for return air as per specifications. Dia 300mm

Nos 10

14

Supply, installation, testing and balancing of GI louvervolume control damper (low leakage) made out of1.6mm thick galvanised sheet steel frame and blades of1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow andfor proper balancing of air distribution system.

Sq.m. 36

Page 94: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

15

Supply, installation, testing and commissioning ofmotorised damper complete with control panel, actuator,CO2 sensors and transmitters, control / communicationcables, etc for Demand Control Ventilation System. Thecontrol panel shall be suitable for BMS intergration

a Motorised Dampers. Sq.m. 8

b Control Panel & Wiring (including actuators). Nos 28

16

Supply, installation, testing and commissioning ofmotorised combined smoke & fire damper complete withcontrol panel, actuator, sensors and transmitters, control /communication cables, etc. The power for actuator shallbe derived from the AHU starter panel.

a Smoke & Fire Dampers. Sq.m. 57

b Control Panel & Wiring (including actuators). Nos 107

17Supply and installation of Powder coated extrudedaluminium grilles with 0 degree deflection with volumecontrol damper for exhaust air as per specifications

Sq.m. 6

18

Supply and installation of Powder coated extrudedaluminium air transfer door grilles comprising of frontsection with inverted ‘V’ horizontal blades, borders,countersunk for screw fixing, and matching rear side frameflanges of 500x300 sizes.

Nos 60

19

Supply and installation of Aluminium powder coated freshair intake / outlet grille complete with volume controldamper, vermin netting and 45 deg angle suitable forprotection against splashing rain water fixed in a powdercoated Aluminium angle mount frames.

Sq.m. 22

20 Supply, installation, testing and commissioning of 1.5mlength sound attenuators as per specifications Sq.m. 3

21 Supply, installation, testing and commissioning of crosstalk attenuators at return air path as per specifications Sq.m. 24

G VENTILATION SYSTEM

1

Supply, installation, testing and commissioning ofVentilation fans consists of GSS rectangular cabinet,centrifugal blower with backward/forward curved blades,fan motor, removable access door for easy accessibility tomotor and fan, flanged inlet and outlet for easy duct workconnection, thermally protected motor and necessarysupports. Motors shall be suitable for 3 Phase or 1 PhaseAC supply, fan efficiency greater than 75% and thecapacity are as follows. (Weather proof for outdoor typefans and no weather proof for indoor type fans)

Air flow rate : 5400CFM (Toilet exhaust) - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Powerrating:2.20kW

Air flow rate : 3100CFM (Toilet exhaust) - Outdoor type

a Nos. 2

Page 95: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Ex. Static Pressure : 30 mmWG, Max Powerrating:1.10kW

Air flow rate : 2920 CFM (Toilet exhaust) - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Powerrating:1.10kW

Air flow rate : 650 CFM (Smokeroom exhaust) - Outdoortype

Ex. Static Pressure : 25 mmWG, Max Powerrating:0.30kW

Air flow rate : 400 CFM (Toilet exhaust) - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Powerrating:0.30kW

Air flow rate : 200 CFM (Toilet exhaust) - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Powerrating:0.10kW

Air flow rate : 1550 CFM (Electrical Room exhaust) -Outdoor type

Ex. Static Pressure : 25 mmWG, Max Powerrating:0.60kW

Air flow rate : 2100 CFM (Electrical Room exhaust) -Outdoor type

Ex. Static Pressure : 25 mmWG, Max Powerrating:0.75kW

Air flow rate : 7200 CFM (Staircase presurrisation) - Dualspeed - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW

Air flow rate : 6900 CFM (Staircase presurrisation) - Dualspeed - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW

Air flow rate : 6600 CFM (Staircase presurrisation) - Dualspeed - Outdoor type

Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW

Air flow rate : 8000 CFM (Liftwell presurrisation) - Outdoortype

Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW

Air flow rate : 7500 CFM (Liftwell presurrisation) - Outdoortype

Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW

Air flow rate : 2050 CFM (Kitchen - Fresh air) - Outdoortype

Ex. Static Pressure : 30 mmWG, Max Power rating:1.0kW

Air flow rate : 2350 CFM (Kitchen - Exhaust) - Outdoortype

Ex. Static Pressure : 40 mmWG, Max Powerrating:1.30kW

n Nos.

o Nos.

k Nos.

l Nos.

m Nos.

h Nos.

i Nos.

j Nos.

e Nos

f Nos

g Nos

b Nos.

c Nos.

d Nos.

1

1

1

3

1

1

2

1

1

4

1

1

1

1

Page 96: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

2

Supply, installation, testing and commissioning of DirectDriven smokespill Tube/Vane Axial fans with inlet & outletprotection net. Fan shall be AMCA certified for Air &Sound performance, balanced to vibration grade of G2.5as per AMCA 204. Fan shall be complete with GSS casing( 220 GSM ), Aluminium impeller, Motor Class H, specialrated motor certified for 250 Deg C for 2 Hrs -415/3P/50Hz. Complete assembly shall be certified for250 Deg C for 2 Hrs. fire rating as per BS 7346 Part 2:1990 Class B or EN 12101-3 & the copy of the Fire-testreport has to be submitted for the approval. These fansshall run during Normal as well as fire mode. Max motorrating: 18.5 kW

Air Flow: 57,000 cfm & Static pressure: 25mm WG. Nos. 3

3

Supply, installation, testing and commissioning of InducedAir Axial Jet fans. Fan shall be AMCA certified for Air &Sound performance, balanced to vibration grade of G2.5as per AMCA 204. Fan shall be complete with GSS casing(220 GSM ), Aluminium impeller, Motor Class H, specialrated motor certified for 250 Deg C for 2 Hrs -415/3P/50Hz, inlet & outlet protection net. Completeassembly shall be certified for 250 Deg C for 2 Hrs. firerating as per BS 7346 Part 2: 1990 Class B or EN 12101-3 & the copy of the Fire-test report has to be submitted forthe approval. The Locationing of the jet fans has to bedone in such a way that the Air velocity at any point on theplane of 1m from the ground level should not be less than0.25m/s during the normal mode. Each fan shall becomplete with Dual speed motor.

Nos. 18

4

Supply, installation, testing and commissioning ofElectrical cum PLC panel with feeders and suitable DOLstarters for Axial Fans and Jet fans of 0.11 / 0.75 kW dualspeed motor built in logic controller. The panel shall caterall axail fans and Jet fans controlled by CO sensor. Thepanel shall be with switch gears, suitable incomer MCCB,Bus bar, PLC and necessary control wiring and indicators, suitable starters, etc to successful operation. The rateshall be inclusive of necessary hardware and software forintegrating the Electrical cum PLC panel / Jet fans / MainExhaust fans / CO sensors / etc. All the equipment shallbe IBMS compatible and required provision shall be madeby the ACMV contractor.

Lot 1

5 Computing and submitting the CFD analysis for thebasement leading to the selection & location of the fans. Lot 1

6

Supply, installation, testing and commissioning of COsensor located at basement for maintaining air qualityusing jet fans. The sensor shall be microprocessor basedand shall incorporate suitable measurement techniques tobe capable of generating an output signal proportional tolevel of contamination by cabron Monoxide and otherathmospheric pollutants.

Nos. 9

7

Supply and fixing of Acoustic Silncers for exhaust fansinlets with 1000 mm long, with 50mm thick 32kg/m3density fibre glass, 2 layers of RP tissue, 22G perforatedaluminium cover sheet, Fixing bolts, supportingarrangements,etc.

Nos. 3

H Supply, installation, testing & commissioning and handing over of the following:

1 VARIABLE AIR VOLUME BOXES (Damper Actuator Typebased on temperature)

Page 97: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Supplying, installing, testing and commissioning ofPressure Dependent Type Variable Air voulme Terminalunits, suitable for installtion in horizontal ducts. The casingshall be double skin acoustically lined and constructedwith galvanised sheet steel. Vendor should include allaccessories such as single / multi leaf damper (withequal% characteristics), actuators, control cabling ,thermostat, temperature sensor, pressure sensor, powercabling from nearest socket and feedback control cablingupto VFD panel / DDC panel in AHU room and any otherancilary requirement for the functioning of the units. Therate shall inclusive of BCU / Hardware & Software forBMS integration to tansfer minimum 4 points from eachVAV Box as listed in the Specification

The minimum air flow is zero and the maximum air flow(cfm) as follows

a 500 cfm Nos. 6

b 750 cfm Nos. 8

c 1000 cfm Nos. 15

d 1250 cfm Nos. 4

e 1500 cfm Nos. 3

f 1750 cfm Nos. 1

g 2000 cfm Nos. 3

h 2250 cfm Nos. 5

i 2500 cfm No. 3

j 2750 cfm Nos. 3

k 4000 cfm No. 2

l 4500 cfm Nos. 4

Page 98: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

m 5000 cfm No. 2

n 6000 cfm Nos. 4

o 7000 cfm Nos. 2

p 7500 cfm Nos. 2

I ACMV RELATED ELECTRICAL ITEMS

1

Supply, fabrication, testing and commissioning of 400ATP+N isolator suitable for termination of chiller powercable. The inlet cable shall be 1 runs of 3.5 Core 240Sq.mm XLPE Aluminium armoured Cable and the outletshall be 1 runs of 3.5 Core 240 Sq.mm XLPE copperarmoured Cable with all necessary controls andaccessories

Sets 3

2 PUMP PANEL

Design, supply, fixing, testing and commissioning ofcubicle type floor mounting switch board comprising of thefollowing, the board shall be fabricated as per the detailedspecification enclosed. (Pump Panel)

INCOMING400A TPN MCCB 35 KA with connected accessories –1No.as incomer OUTGOINGS100A TPN MCCB, 16 KA – 8Nos63A TPN MCCB, 16 KA – 4NosWith necessary copper busbars, interconnections,providing Digital type voltmeter, ammeter with selectorswitches, ON,OFF,TRIP, phase indication lamp, Fuse,Switch control etc.and also refer the drawing.The incoming and outgoing breakers shall beMicroprocessor based release such as overload,shortcircuit,earth fault,neutral protection,etc.

400A Amps TPN copper busbars : All the neutralbusbars shall have half the capacity of phase busbars(1.2A/Sq. mm.).

Nos 1

3

Supply erection testing and commissioning of thefollowing starter panel with Ammeter, selector switch,suitable ratio of CTs,control fuses, Auto/Manual selectorswitch, on/off/trip indication lamp with necessary powerand control wiring interconnections etc.,with suitableprovision to link with IBMS for remote operation and allconnected necessary accessories in a suitable MSenclosure with painting , earthling and suitable fixingarrangement as required.

a

1No. 100A TP&N MCCB with adjustable variable settings16 KA with all connected accessories. 1 No. Star Deltastarter (3 Phase) suitable for 17 KW for condenserwater pump

Nos 3

b

1No. 63A TP&N MCCB with adjustable variable settings16 KA with all connected accessories. 1 No. Star Deltastarter starter (3 Phase) suitable for 11 KW for coolingtower

Nos 3

c

1No. 32A TP&N MCB with adjustable variable settings 16KA with all connected accessories. 1 No. DOL starter (3Phase) suitable for 3.7 KW for ceiling suspendedAHUs

Nos 3

Page 99: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

d

1No. 63A TP&N MCCB with adjustable variable settings16 KA with all connected accessories. 1 No. Star Deltastarter (3 Phase) suitable for 18.5 KW for Basementexhaust fan

Nos 3

e1No. 16/20A TP&N MCB with adjustable variable settings10 KA with all connected accessories. 1 No. DOL starter(3 Phase) suitable for 1.1 KW for Dual Speed Jet fans

Nos 18

f

1No. 32A TP&N MCB with adjustable variable settings 16KA with all connected accessories. 1 No. DOL starter (3Phase) suitable for 4.0 KW for Staircase/ Liftwellpressurisation fans (Dual speed)

Nos 8

g1No. 16/20A TP&N MCB with adjustable variable settings10 KA with all connected accessories. 1 No. DOL starter(3 Phase) suitable for upto 2.5 KW for exhaust fans

Nos 6

4 Supply & installation of 16/20A DP MCB with Suitableenclosure box for 1 phase ventilation fan Nos 8

5 Supply & installation of 6/16A SP MCB with Plug Top andBase Box and other associated accessories as required Nos 95

6 Supply and fixing of lockable type push button control forON / OFF Nos 66

7 CABLES AND TERMINATION

Supply, Laying, Testing and Commissioning of thefollowing size PVC insulated and PVC sheathed / XLPEPower cable of 1.1KV grade Aluminium / Copperconductor armoured / unarmoured cables. Cables shallbe laying on the cable tray and partially laid onwall/ceiling with suitable clamps & necessary fixingaccessories etc. as required.

a 3.5 Core 240 Sqmm XLPE Arm. Cu.cable Rmt 30

b 3.5 Core 50 Sqmm XLPE Arm. AL.cable Rmt 90

c 4 Core 25 Sqmm XLPE Arm. AL.cable Rmt 115

d 4 Core 16 Sqmm XLPE Arm. AL.cable Rmt 240

e 4 Core 4 Sqmm XLPE Arm. Cu.cable Rmt 500

f 4C 2.5 Sqmm XLPE Arm. Cu. Cable Rmt 40

g 3C 2.5 Sqmm XLPE Arm. Cu. Cable Rmt 90

h 3C 1.5 Sqmm XLPE Arm. Cu. Cable Rmt 715

Page 100: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

8

Supply, termination and commissioning of the followingsize cables with suitable double compression glands andcrimping socket with suitable earth clip & fixingaccessories.

a 3.5 Core 240 Sqmm XLPE Arm. Cu.cable Nos 4

b 3.5 Core 50 Sqmm XLPE Arm. AL.cable Nos 24

c 4 Core 25 Sqmm XLPE Arm. AL.cable Nos 14

d 4 Core 16 Sqmm XLPE Arm. AL.cable Nos 48

e 4 Core 4 Sqmm XLPE Arm. Cu.cable Nos 50

f 4C 2.5 Sqmm XLPE Arm. Cu. Cable Nos 12

g 3C 2.5 Sqmm PVC Arm. Cu. Cable Nos 14

h 3C 1.5 Sqmm PVC Arm. Cu. Cable Nos 190

9 EARTHING

a Supply and laying of 8 gauge bare copper conductor forequipments earthing. Rmt 210

b Supply and laying of 10 gauge bare copper conductor forequipments earthing. Rmt 150

10 Supply and laying of 25x3mm bare copper strip forequipments earthing. Rmt 120

Cable Trays / Accessories and Supports

11 Supply and Installation of the following Cable Trays /Accessories Prefabricated hot dip galvanised 2.5mm thick sheetperforated / Ladder type cable tray including allnecessary curved bends‐tees‐reducers, coupler plates,fastners etc.,for the following sizes. Inclusive necessaryfixing arrangement etc.

a 300mm Wide Ladder Rmt 20

b 150mm Wide Ladder Rmt 20

c 300mm Wide Tray Perforated Rmt 40

Page 101: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

d 150mm Wide Tray Perforated Rmt 50

12

Supply and Installation of MS flat / angle iron supportsfor various purpose if required with various sizesincluding cutting,welding,grinding,fixing accessories andone coat of primer & two coats of enamel paints, minorcivil works etc. as required.(Note: The flat / angle ironweight will be arrived on the basis of theoreticalcalculation only).

MT 0.5

TOTAL AMOUNT OF HVAC WORKS

Supply, intallation, testing and Commissioning of the following system as per the technical specification.

A-I FIRE ALARM SYSTEM.

1

Analogue addressable micro Process -controlled Fire Alarm Control Panels, capable ofbeing IP networked to the central monitoringSystem, to monitor and integrated the followingquantity of accossries like detectors,MCP's/hooters/control modules, Fault IsolationModules, hooters, response indicators, fire/faultindicators, audio-visual signals, centralprocessing units, complete with LCD display,zone indicating LEDs as per the detailedspecification: complete with Battery backup withcharger for each panel. Each loop shouldprovided with minimum 125 detectors /devices

a8 LOOP PANEL expendable to 12 Loop .

1 Set

b1 LOOP PANEL-Substation expendable to 4

loop1 Set

Note: Providing Windows based graphical

software, (with necessary software addresses

required as per BOQ) on MS windows 2000/XP

or latest platform,including Alarm Management

for IBMS as per the above itemRATE OF RISE HEAT DETECTORS :

2

Supply, Installation, Testing and Commissioningof Rate of Rise Heat Detectors (ThermalDetectors):GRADE-I Addressable analogue typeHeat Detectors with solid state design withsensing element combination of fixed type andrate of rise of temperature indicating LED, withinbuilt isolator or isolator in basecomplete withbase etc. as per detailed specifications.

140 Nos.

SMOKE DETECTORS

3

Addressable analogue MUTISENSOR typesmoke detectors with dual scattering withthermal sensing, solid state design, indicatingLED,with inbuilt isolator or isolator in base withmounting base etc. as per detailed specification.The rate shall inclusive of necessary base box,connecting glad for above detectors

600 Nos.

IBMS WORKS

Page 102: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

4Duct detector suitable for providing the return air path with suitable fixing accessories 20 Nos.

ELECTRONIC HOOTERS :

5

Hooter with relay module and storb light withminimum 85 db audiable and control relaymodule, power supply units etc 90 Nos.

MANUAL CALL POINTS :

6

Manual call points pull stations of approvedmake with NO/NC contacts slim type andprojecting out from the surface of enclosurewithglass suitable for addressable function withinbuilt isolator.

45 Nos.

CONTROL MODULE

7

Addressable control module to trip the AHU,s,Access door, triggering the DVR.lift landing etc 50 Nos.

8

Addressable monitor module along with door contact for Fire doors

25 Nos.

RESPONSE INDICATOR

9

Response indicator for mounting on false ceilingat the entries of the cabin for indicating theoperation for detectors in the above areas. 280 Nos.

LPG GAS DETECTOR

10

Supply, fixing, testing and commissioning ofLPG gas detection system for Canteen area

4 Nos.

CABLES / WIRES

11

Supply and fixing of 2C 1.5 armoured copperFRLS cable in celing with suitable clamps andscrews (RED colour) 14000 Mtrs

12

25mm dia GI conduit for laying of fire cableincluding necessary accessories like bend,junction box fixing of clamps etc., complete.The conduit shall be recessed in wall includingchipping, roup plastering etc. (only for theDrops - MCPs)

300 Mtrs

BEAM DETECTOR

13

Supply, fixing, testing and commissioning ofWall mounted type Beam detector with receivercoverage of minimum 25 mtr distance as perdetailed specifications. The adjustable angle

shall be +/- 10o for both vertical and Horizontal.The detector should be capable of connecting toexisting Addressable fire alarm panel.

15 Set

Total of A-I C/o to summary

A-II PUBLIC ADDRESS SYSTEM AND EVCSYSTEMSupply, intallation, testing and

Commissioning of the following system as

per the technical specification.

Page 103: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

14

Supply, Installation, Testing and Commssioiningof System Controller complete with 16 Zone CallStation, Stem Type Microphone, 2 mm thickCRCA Sheet Powder Coated Rack, Dual ToneControl for Speech & Music, integration facilitywith Fire Alarm System, tone generator &Speech Processor with relays for activating tone& pre-recorded fire alarm messages, facility tointregrate with the base builder P.A System asspecified in the Tender Specifications . The rateinclusive of Periarity module, selector switch etc

1 Each

15

Supply, intallation, testing and Commissioning of19" Rack 650mm depth, 19U high amplifierrackassembly made of aluminium channel , with sideand rear panels made of 14 swg powder coatedsheet steel front transparent persplexdoor andwith rails, rollers & bearings. Fans provided atthe top for ventilation side panels will beventilated type.The rack shall be powder coatedof approved color and spare 'U' shall be coveredwith blank panels.

1 Each

16

Supply, Installation, Testing and Commssioiningof 20 W Wall/Column Mounted Speakers withline matching transformers and selectedable tapsetting as specified in the TenderSpecifications

25 Set

17

Supply, Installation, Testing and Commssioiningof 6 W Wall Mounted Speakers with linematching transformers & selectedable tapsetting as specified in the TenderSpecifications for electical rooms and AHUrooms

40 Set

18

Supply, Installation, Testing and Commssioiningof 6 W Ceiling Mounted Speakers with linematching transformers & selectedable tapsetting as specified in the TenderSpecifications for false ceiling areas.

210 Set

19

Supply, Installation, Testing and Commssioiningof Rack Mounted minimum 480 W PowerAmplifier as specified in the TenderSpecifications 4 Set

20

Supply, Installation, Testing and Commssioiningof Rack Mounted minimum 120 W PowerAmplifier as specified in the TenderSpecifications 3 Set

21

Supply, Installation, Testing and Commssioining of Supply & Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications

7500 Mtrs

22

Supply, Installation, Testing and Commssioining of Micro phone unit with back box, STAND LEGNTH OF CABLES 1 No

Page 104: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

23

Supplying, installing, testing and commissioningof 1 No. each of AM/FM Tuner, DVD player withoverriding facility, Music Source Selector, withassignable priority on each channel to accept

1 No

24

Auto dialar for intefacing with Fire alarm system

1 No

25

16 Zone Auto speech processor (Digital Voice Recorder) for fire activation message 1 No

A-III ACCESS CONTROL SYSTEMAccess control system complete withnecessary hardware, Software etc., asspecified for centralized securtiymonitoring. Supply, intallation, testing andCommissioning of the following system asper the technical specification.

Access Controllers, each with capacity of10000 events buffer memory connecting the theitem listed below such as card readers,Magnetic locks, boom barriers etc

262 door - 2 reader controller

1 Each

27Proximity Card readers with stainless steelbase plate 2 Nos

28Electromagnetic Locks - Double Door

1 Nos

29Magnetic Contact

2 Nos

30Emergency push button (glass type)

1 No

31 FRLS sheilded Cables:

a

Cable from electromagnetic lock/Sensor to Controller - 1 Sqmm 4 C sqmm multistand armoued shilelded cable 300 Mtrs

bCable from Reader to Controller - 1 Sqmm 6 Csqmm multistand shielded armoured cable 300 Mtrs

cNetwork cable for controller to controller -Armoured cable 300 Mtrs

32

Access management software with time andattendance module suitable for flexi time reportregenration as per client requirement with SQL/Oracle data base.

1 Each

33 Proximity Card with holder, Lanyard, Adhsive lables for printing the ID card 10 Each

34

Supply and commissioning of Single Door Panic bar with Contacts and hooterfor all Fire Doors for monitoring door status with necessary hardware as specified for centralized securtiy monitoring. The local alarm panel shall have provision for reset key with external Key switch.

9 Set

Page 105: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

A -I V CLOSED CIRCUIT TELEVISION SYSTEMSupply, installation, testing and commissioning of following system:

35

Colour 1/3" fixed dome indoor camera , 520 TVlines resolution and minimum lux level not morethan 1.2 lux (F1.2) including all mountingsupports / brackets and fixing accessories.

23 Nos

36

Color high speed 1/4" Pan/Tilt/Zoom indoorcamera, 520 TVL (PAL)lines resolution andminimum lux level not more than 0.05 lux atF1.2 with 23X optical or better motorized zoomlens, receiver, driver, Pan/Tilt and necessaymounting support / bracket, accessories asrequired for indoor installation. and mountingsupport as per specification.

6 Nos

37

Color high speed 1/4" Pan/Tilt/Zoom outdoorcamera, 520 TVL (PAL)lines resolution andminimum lux level not more than 0.05 lux atF1.2 with 23X optical or better motorized zoomlens, receiver, driver, Pan/Tilt and necessaymounting support / bracket, accessories asrequired for outdoor installation along withstandard outdoor enclosure with suitableaccessories and mounting support as perspecification.

6 Nos

38Power Supply Unit fixed cameras-12V

23 Nos

39DC/AC Power supply unit as required for the PTZ cameras-24V 12 Nos

40

16 Channel Duplex Digital Video Recorder formultiplexing and digital recording , suitable forlive viewing and playback while recording ,Motion detection, alarm event detection withTCP / IP connectivity - Hard disc capacity 4TB

3 Nos

41

46" diagonal, 1920 x 1080 pixels LED televisionwith all mounting bracket, connection card wire,remote control etc as per the specification. 2 Nos

Cables:

42Supply and laying of RG 11Coaxial armoured

Cable5000 Mts

43Supply and laying of 2 Core 1.5 Sqm Twisted pair Shielded armmoured FRLS cable for PTZ operation

2500 Mts

44Supply and Fixing of 25 MM GI conduit with all necessary accessories. 100 Mts

456 Mtr height GI post with necessary mounting bracket, weather proof box and Civil works for external cameras.

6 Nos

46Mounting bracket with accessories for external camera mounted at terrace . 6 Nos

473 Core 2.5 Sq.mm copper armoured Cable

power4000 Mtr

Page 106: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

A-VINTERGRATED BUILDING MANAGEMENT SYSTEM AND BUILDING MANAGEMENT SYSTEM:BAS SERVER

48

Design supply, installing, testing andcommissioning Microprocesser based Intergrated Building Management System as perthe detailed specifications for complete andsatisfactory operation and control and to localauthorities approval. Main stations andsubsystems with LAN, complete with hardwareand software to provide graphical usersinterface consisting of System PC comprisingIntel core i 7 Ghz Processor , 4GB DDr2 RAM @ 667 Mhz , 500 GB HDD , Keyboard, Opticalmouse, ATX P IV Cabinet with SMPS PrimeSource, DVD Writer, Speaker with WindowLatest operating system. The system should besupplied with 21" TFT Color Monitor. .Servicepack XP-2 (Main server - HOT Stand by /Parallel reduendancy mode) (1 set = 2 nos)

1 Set

GRAPHICAL SOFTWARE

49

Providing Windows based graphical software,(with necessary software addresses required asper I/O list) on MS windows 2000/XP or NTplatform,including Alarm Management for IBMSas per the above item

1 Set

SOFT POINTS

50

Providing necessary Software and Hardware forInterfacing through a gate way for monitoringthrough serial Modbus interface for the datapoints for Chillers , VFDs , VAVs, etc as perthe detailed IO summary in HVAC tender .Total soft points 950 pts including energymeters, UPS etc

1 Set

MONITORING STATION AND PRINTERS:

51

Monitoring station as per technical specficationand system PC comprising Intelcore T2 Duo 2.8Ghz Processor @ L2 Cache 3 MB intel 31 PRmother board, 4GB DDr2 RAM @ 667 Mhz ,250GB HDD , Keyboard, Optical mouse,externalspeakers, sound card ATX P IV Cabinet withSMPS Prime Source,DVD Writer,Service packXP-2 with Window NT/2000 operatingsystem.The system should be supplied with 21"TFT Color Monitor.- 1. FIRE & BMS PC 2. CCTV & ACCESS PC

2 Each

a Supply and commissioning of 600 DPI Colour Inkjet Printer 1 Each

b Supply and commissioning of Single A4 size Laser Printer 1 Each

52 DIRECT DIGITAL CONTROLLER:

Page 107: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

Supply, installation, testing and commissioningof Autonomous networkable DDC Controllerwith 32 bit microprocessor based standaloneand networkable type with real time clock andhistorical database of min 1 Mb with panels,peer to peer communicable DDC modules, inputor output relays, terminal block, real time clock,networking and inbuilt data buffer for Followingrequirement as per Enclosed IO summary .

a

DDC-TYPE A (Chiller+VFD Pump+CondensorPump+ Fan) 1 Set

b

DDC-TYPE B (1 AHU+1 TFA)

4 Set

c

DDC-TYPE C (2 AHU + 2 CSU/FCU)

4 Set

d

DDC-TYPE D (1 lift well pres. + 1 No. stair. Prs.)

4 Set

e

DDC-TYPE E (Electrical panel at substation)

1 Set

f

DDC-TYPE F (Lift panel)

1 Set

g

DDC-TYPE G (UPS)

1 Set

h

DDC-TYPE H (Basement Exhaust & jet Fan)

1 Set

FIELD EQUIPMENT:

53Supply, installation, testing and commissioning of water level indicator ( Step sensor) for UG sump / Tank.

a 3000 mm 5 Nos.

54 For Chiller

a

Supply, installation, testing and commissioning of immersion type temperature sensor and thermowell across the chiller pipe (Supply header,Return header,Supply header before bypass line and Return header before bypass line) as per the system requirements for BAS system

8 Nos

b

Supply, installation, testing and commissioning of Differential-pressure transducer across the Chiller header (Supply & Return) as per the system requirements for BAS system 1 Nos

Page 108: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

c

Supply, installation, testing and commissioning of Flow sensor at chilled water flow as per the system requirements for BAS system

3 Nos

d

Supply, installation, testing and commissioning of Ultrasoni meter/BTU meter as per the system requirements for BAS system

2 Nos

eSupply, installation, testing and commissioning of Differential-pressure Switch across the pumps as per the system requirements for BAS system

8 Nos

f

Supply, installation, testing and commissioning of Pressure transducer across the Chiller header (Supply & Return) as per the system requirements for BAS system

2 Nos

55 For AHU

a

Supply, installation, testing and commissioning of immersion type temperature sensor in AHU CHW Inlet pipe as per the system requirements for BAS system.

16 Nos

b

Supply, installation, testing and commissioning of Temperature (Supply & Return air) with necessary accessories to monitoring the conditioned area temperature as per the system requirements for BAS system

30 Nos

d

Supply, installation, testing and commissioning of Duct static pressure sensor to measure the static pressure in duct as per the AHU I/O listed for BAS system.

14 Nos

e

Supply, installation, testing and commissioning of Differential pressure switch to monitor Filter & Fan status as per AHU I/O listed for BAS system 40 Nos

f

Supply, installation, testing and commissioning of Flow meter to measure the air flow of AHU at Plenum as per the AHU I/O listed for BAS system

14 Nos

56 For TFA

a

Supply, installation, testing and commissioning of Temperature (Exhaust & Fresh air) with necessary accessories to monitoring the conditioned area temperature as per the system requirements for BAS system

15 Nos

b

Supply, installation, testing and commissioning of Differential pressure switch to monitor Filter & Fan status as per TFA I/O listed for BAS system 22 Nos

Page 109: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

c

Supply, installation, testing and commissioning of outdoor Temperature sensor

4 Nos

d

Supply, installation, testing and commissioning of Duct static pressure sensor to measure the static pressure in duct as per the TFA I/O listed for BAS system. 4 Nos

e

Supply, installation, testing and commissioning of Flow meter to measure the air flow of AHU at Plenum as per the TFA I/O listed for BAS system 4 Nos

f

Supply, installation, testing and commissioning of immersion type temperature sensor in AHU CHW Inlet pipe as per the system requirements for BAS system. 4 Nos

g

Supply, installation, testing and commissioning of Indoor CO2 sensor 20 Nos

hSupply, installation, testing and commissioning of Outdoor CO2 sensor 4 Nos

57 For Lift well/stairecase Pressuration Fan

a

Supply, installation, testing and commissioning of Differential pressure switch to monitor Filter & Fan status as per I/O listed for BAS system 20 Nos

58 CABLES / WIRES FOR IBMS

a

2 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multistranded, Unscreened cable. [For ON / OFF Command & various status, Supply for Field Devices]

4000 Mtrs

b

2 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multistranded, screened cable. [For Sensors] 2000 Mtrs

c

4 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multistranded, screened cable. [For Sensors] 2000 Mtrs

d

Supply and laying of Communication cable/bus cable to intergate all DDCs, BTU meters, VAVs etc - Armoured 2000 Mtrs

e

Supply and laying of 25 mm MS conduit for the abvoe

200 Mtrs

Page 110: RITES Ltd. Civil work (Based on ... 4 Electrical work (Based on Market Rate) Total Amount Un-conditional rebate if any Amount ... cement per CUM of concrete instead of M25

In Figure In words

Amount in Rs.S.No. Description Qty Unit Rate

f

3 Core 2.5 Sq.mm copper armoured Cable for

Power

1000 Mtrs

A -VI Miscellaneous itemsSupply, Installation, testing and

Commissioning of the following system

59

Supply and installation of following size slottedangle GI ready made cable trays of 14 SWG GIsheet. The Quoted rates for installation shallincluding necessary anchor fasteners and 'L'angle supports @ 600mm interval etc., to suitsite conditions as required.

a150 mm wide

250 Mtrs

b300 mm wide

250 Mtrs

c450mm wide

150 Mtrs

60

Wiring to the IBMS equipment using 2 R uns of2.5 Sqmm insulated copper cable and 1R-1.5 Sqmmof earthing inside the suitable size GIconduits with clamp and fixing accessories - Thesupply should be taken from existing UPS DB.

3500 Mtrs

61

Supply of 6 A 3-Pin Socket mounted on PVCBox which has to be fixed in wall as required.The Socket should be of modular type 75 Each

62

Excavation of ground to a depth of 3' level andwidth of 1' and refilling elc.for laying the PVCpiping. Extra earth after fe-filling to be leveled inlow lying area as directed by the Site incharge.

400 Mtrs

63Supply, laying of 110 mm dia 6Kg/cm2 PVC pipein execavated ground. The rate shall includingnecessary coupler, bend etc.

400 Mtrs

TOTAL AMOUNT IBMS WORKS