Page 1: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

RIGEL

CONDENSING

COMBI

BOILER

Read carefully before operat�ng the appl�ance

COMBI BOILER INSTALLATION AND USER’S MANUAL

Page 2: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment
Page 3: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

INDEX

1. INTRODUCTION

2. WARNINGS FOR THE USER

3. CONDITIONS INELIGIBLE FOR WARRANTY

4. SWITCHING ON THE BOILER

5. DAILY OPERATION OF THE BOILER

6. FILLING THE BOILER

7 . SWITCHING OFF THE BOILER

8 . MAINTENANCE OF THE BOILER

9 . INSTALLATION INSTRUCTIONS

10 . DIMENSIONS OF THE BOILER

11 . CONNECTING THE FLUE

12 . ELECTRIC CONNECTION

13 . ELECTRIC SCHEME AND ROOM THERMOSTAT

14. ERROR CODES 4IOS AND ANDROID, ALL VERSIONS

15 . TECHNICAL DATA

1

1

1

2

3

4

4

5

5

6

7

9

9

11

12

Page 4: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

1

a. Installa�on and connec�ons of the boiler must be carried out in full conformity with the governing legal regula�ons, the requirements of local gas distribu�ng Company and the instruc�ons provided by the manufacturer.

d. Ensure that both central hea�ng system and domes�c hot water distribu�on pipes are cleaned properly before the installa�on and connec�on to the boiler. The manufacturer is not responsible of any damages arising from the dirt and small par�cles le� inside the piping and such failures and damages are out of warranty claim.

f. Cleaning of external surfaces of the appliance should be made by using a damp cloth, do not use any chemical or detergent.

b. Arising from installa�ons not confirming the instruc�ons given in this manual as well as those from misuse,

e. The commissioning of the boiler must be performed by qualified personnel/Thermex authorised services only. Ensure that electric, water and gas connec�ons to the boiler are carried out are in conformity with local requirements as well as to the instruc�ons provided in this manual.

e. Physical failures happened a�er the appliance has been delivered,

This installa�on and usage manual contains detailed instruc�ons and recommenda�ons for safe and efficient use of the boiler, further this manual contains technical data, informa�on for installa�on and connec�ons, use, maintenance, troubleshoo�ng and explana�on of the most possible failures of the appliance

Please do not operate your appliance before reading this manual and to keep in a safe place for future reference.

b. Ensure that the flue gas connec�on is not terminated in a closed compartment and connected with no other appliance but the special chimney made to be used for the connec�on of more than one appliance and flue gas outlet cap is not clogged.c. Ensure that the supply gas complies with the gas type, pressure and capacity of the boiler indicated in the data plate.

1 INTRODUCTION

3. CONDITIONS INELIGIBLE FOR WARRANTY

Thermex Rigel PM 24kw-27,99kw-35kw condensing boilers are wall hung boilers designed to produce for hea�ng your house as well as preparing domes�c hot water by using natural gas. The boilers are suitable for natural gas fuel.

The THERMEX warranty claim does not apply any failures arising from any use of the appliance out of such men�oned in this manual as well as from the following cases:

d. Arising from intervening the appliance by an unauthorized service agency,

f. Arising from natural disasters, fire and lightning strike, g. Arising from high or low supply voltage out of the limits stated in the data plate or connec�ons to a power supply line with an inefficient earth connec�on,

a. Happened in appliances not commissioned by authorised THERMEX services,

g. In order to use the appliance efficiently for years to come schedule annual maintenance of the boiler with Thermex authorised service.

c. Arising from selec�ng wrong type of appliance for the intended purpose,

2. WARNINGS FOR THE USER

Page 5: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

2

i. arising from other accessories and ancillary products used with the appliance,

k. Manipula�on of data plate and warranty cer�ficate,l. Using the appliance in a cold water supply network out of the condi�ons set in this instruc�on manual,

Before star�ng the boiler ensure electric, gas and water connec�ons are properly made and the appliance is supplied with correct power as stated in the data plate.

4. SWITCHING ON THE BOILER

The warranty does not apply to above specified failures, and repair of such failures is subject to a fee.

b. Turn gas cock to open posi�on.

h. Arising from the failure of observing the periodic maintenances specified in the instruc�ons to be done in �me by the authorized service agencies,

c. The Central Hea�ng temperature adjustment bu�on serves both “off”and Summer/Winter mode selec�on bu�on. When this bu�on is “off” posi�on the appliance is switched off. When it is “Sun” posi�on the appliance is in Summer mode and only operates for hot water produc�on. When the Central Hea�ng temperature is increased the boiler is in Winter mode and heats central hea�ng as well. Figure 1

WARNING: In Summer mode the boiler does not start unless a hot water tap is opened.

d. Adjust your desired temperature by temperature adjustment bu�ons to put the appliance in opera�on.

j. Arising from freezing

a. Open power supply connec�on.

WARNING: When the boiler is first started the boiler may show igni�on failures and go into block several �mes �ll the air in the gas supply line is evacuated. In that case push Reset bu�on for 5 seconds to restart the boiler.

Page 6: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

3

Figura 1

With summer mode pump an� blocking safety and an�-frost protec�onfunc�ons are ac�ve.

b. When the appliance is Winter mode the display shows ( ) and ( ) signs.To set this mode; just turn central hea�ng temperature adjustment bu�on to minimum se�ng.

WARNING: When the appliance is “Off” mode pump an� blocking safety,an�-frost protec�on and three-way valve motor blocking safetyfunc�ons are ac�ve.

With “only hea�ng” mode pump an� blocking and an�-frost protec�on func�ons are ac�ve.

To adjust domes�c hot water temperature turn ( ) bu�on to your desired temperature.

With winter mode pump an� blocking safety and an�-frost protec�on func�ons are ac�ve.

WARNING: When the boiler switches on a�er a heat demand (when the burner is on), ( ) sign is shown in the display.

c. When the appliance is “only hea�ng” mode the display shows ( ) sig.

To adjust central hea�ng temperature turn central hea�ng adjustment temperature to set the desired temperature.

a. When the appliance is Summer mode the display shows ( ) sign. To set this mode; turn central hea�ng temperature adjustment bu�on to “Sun” symbol. To adjust domes�c hot water temperature turn ( ) bu�on to your desired temperature.

When it is not required to use central hea�ng, the appliance may be switched to Summer mode only to produce domes�c hot water. To set Summer mode simply turn central hea�ng temperature adjustment bu�on to “Sun” symbol.

5. DAILY OPERATION OF THE BOILERSummer/Winter/Only Hea�ng mode selec�on

Page 7: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

44

6. FILLING THE BOILER

When the boiler is cold the installa�on should be filled such that the manometer located in the front of the boiler, (Figure 2) indicates a water pressure between 1-1,5 bar. When the pressure drops to the cri�cal level the appliance shuts-off automa�cally.

Filling water is supplied through the filling valve located in the bo�om of the boiler, Figure 3.

Figura 2

Figura 3

7. SWITCHING OFF THE BOILERTo switch off the boiler turn central hea�ng adjustmentbu�on to “off” posi�on. When the boiler is “off” posi�on the pump an�blockage andan�-frost protec�on are ac�ve and there is electric current in the boiler. In order to switch off the boiler completely, switch the external power supply fuse-circuit breaker to OFF posi�on.

WARNING: In order an�-frostprotec�on to be ac�veelectric and gas supply to the boiler should not be closed. Observe the requirements indicated in Paragraph 4. When the temperature inside the boiler drops below 5°C the burner the an�-frost protec�on switches, turns on the burner and heats the water up to 30°C.

Page 8: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

5

8. MAINTENANCE OF THE BOILERIn order to use your appliance trouble-free and efficiently for long years we recommend scheduling annual maintenance, preferably at early winter season, by Thermex authorised service.

Do not clean external surfaces of your appliance with detergent or chemical materials.

Check your installa�on before making connec�ons to the boiler and ensure that the installa�on pipes are free from dirt or any par�cles.

Boiler, support Styrofoam, installa�on hanging equipment, user’s manual, warranty cer�ficate and service booklet.

The loca�ons where the boiler can be installed should be selected by observing the relevant regula�ons and requirements set forth by standard codes of prac�ce in force as well as local gas company standards. Installa�on hanging equipment should be fixed on the wall in such way to carry the weight of the boiler. The hanging bracket should be fixed level, Figure 4.

The life�me of wall hung combina�on boilers set by the Ministry of Science, Industry and Trade is 15 years. According to the relevant codes the manufacturing companies undertake to maintain and provide required spare parts of the appliance during the set life�me.

9. INSTALLATION INSTRUCTIONSBoiler package contains:

A suitable filter must be installed to the water inlet to the boiler, Figure 5.

Check that the maximum water mains pressure does not exceed 8 bars; if it does, a pressure reducing valve must be installed

Condensate drain should be laid with con�nuous ° downward slope and to be connected to waste water drain. The drain hose should be insulated against freezing.

Make sure that the gas category for which the boiler was designed corresponds to the category available in the loca�on

where it will be used and the supplied gas pressure, as well as the gas installa�on, is in conformity with data plate.

Figura 4

Page 9: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

6

Figura 5

Figura 6

.

Page 10: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

7

The followings must be observed when making flue connec�on:

b. Building aisles,

d. On the chimney walls

11. CONNECTING THE FLUE

When connec�ng the flue, the flue gas accessories supplied by the manufactured must be used. When selec�ng the loca�on of the boiler the posi�on of flue gas connec�on and flue terminal should be considered. For flue connec�on the requirements set forth by the local authori�es and gas distribu�ng company must be observed.

c. Light-wells,

Flue connec�on must not be made to:

b. Minimum ver�cal distance above the ground should be 0,3 m and in places where there is an impact risk the flue terminal must be covered with a wire net.

a. Building stairwells,

e. Balconiesf. Elevator sha�s.

c. When the flue terminal is extended off the wall it must extend minimum 50 mm outside the wall.d. Horizontally connected flue connec�ons must be installed with 5% upward slope.

a. Flue terminal ver�cal distance to eaves and roof coverings should be minimum 1,5 m from the top and should also extend further from such eaves and roof coverings.

e. Where the appliance is installed to penthouses flue terminal should be minimum 40 cm above the roof. In such cases the roof must be insulated with non-combus�ble material. f. Maximum length of the flue connec�on is 9 m. Maximum length is shortened by 1 meter for each addi�onal 90° elbow and 0,5 meter for each addi�onal 45° elbow.g. Roof �ghtness must be fully ensured with ver�cal flue applica�ons. In case where �ghtness cannot be ensured any failure or damage which may arise is out of warranty claim.

Figura 7

8

Page 11: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

8

Figura 8

Figura 9

Figura 10

Page 12: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

9

The appliance must be connected to 220~230V single phase power supply line with efficient earth connec�on through (3-10A)V. Automa�c circuit breaker.

13. ELECTRIC SCHEME AND ROOM THERMOSTAT

12. ELECTRIC CONNECTIONThe appliance must be connected to a power supply line with an efficient earth connec�on.

To use a room thermostat capable of controlling all func�ons of the boiler including domes�c hot water produc�on (opentherm) , contact with your authorised service agency. Such room thermostats may provide internet connec�on and remote access may be made. If required, you may control the appliance through a computer or smart phones and tablets that provide required features.

The room thermostat connec�on is provided through 6-point connec�on at the outlet of the control panel cable. Room thermostats which have not opentherm features may be connected here removing short circuited bridge connec�ons. These connec�ons are also suitable for both simple type and digital type room thermostats

Page 13: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

10

Figura 11

Page 14: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

11

2.L 2 STB thermostat.

The fail is signalled, all requests are inhibited, the TWV is switched in CH direc�on and the Pump is ac�vated un�l the STB is open. It’s cleared by the Reset ac�va�on if STB isclosed.

Figura 12

14. ERROR CODES The appliance displays certain failures or warnings on the display to inform the user, Figure 12. In such case if the error does not disappear a�er performing the indicated ac�on the closest authorised service must be called to fix the error of the appliance.

Page 15: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

12

Figura 13

Page 16: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

13

Page 17: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

14

Page 18: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment

Dear Customer, Thank you for choosing a Thermex product.

www.thermex.com.tr

0850 775 05 15

15

Page 19: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment
Page 20: RIGEL CONDENSING COMBI BOILER - THERMEX · WARNING: In Summer mode the boiler does not start unless a hot water tap is opened. d. Adjust your desired temperature by temperature adjustment