FL # FL19002-R1
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Enviralum Industies Inc
Address/Phone/Email 5100 NW 72 Ave.Bldg CMiami, FL 33166(305) [email protected]
Authorized Signature Frank [email protected]
Technical Representative Frank Messa
Address/Phone/Email 5100 NW 72 Ave. Bldg. CMiami, FL 33166(305) [email protected]
Quality Assurance Representative
Address/Phone/Email
Category Panel Walls
Subcategory Storefronts
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed FloridaProfessional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed theEvaluation Report
Javad Ahmad
Florida License PE-70592
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ammad Riaz, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL19002_R1_COI_SS - ENV-450 Alum. Window Wall System (LMI)-CI2017.pdf
Referenced Standard and Year (of Standard) Standard Year
AAMA 501 2005
TAS 201 1994
TAS 202 1994
TAS 203 1994
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...
1 of 2 1/6/2018, 8:21 AM
Equivalence of Product StandardsCertified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/18/2017
Date Pending FBC Approval 08/23/2017
Date Approved 10/10/2017
Summary of Products
FL # Model, Number or Name Description
19002.1 ENV-450 Aluminum Window WallSystem
Large missile impact resistant aluminum window wall systemw/ or w/o thermal break.
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +100/-131Other: See installation drawings W15-74 for span vs. load
combinations and installation details.
Installation InstructionsFL19002_R1_II_SS - ENV-450 Alum. Window Wall System(LMI) - 2017 DWG W15-74.pdf Verified By: Javad Ahmad 70592 Created by Independent Third Party: YesEvaluation ReportsFL19002_R1_AE_SS - ENV-450 Alum. Window Wall System(LMI)-PAE 2017.pdf Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mailto this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), FloridaStatutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails providedmay be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the
Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw...
2 of 2 1/6/2018, 8:21 AM
9360 Sunset Drive STE 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | [email protected]
PRODUCT APPROVAL EVALUATION RULE CHAPTER #61G20-3 • METHOD 1 OPTION D
FL 19002 Date: 8/16/17
Detailed Product Description: Manufacturer: ENVIRALUM INDUSTRIES, INC Manufacturer Address: 5100 NW 72ND AVENUE, BLDG C. MIAMI, FL 33166 Model Name: SERIES “ENV-450” ALUMINUM WINDOW WALL SYSTEM Maximum Frame Width: 72” Maximum Frame Height: 144” Maximum Load: +100 PSF, -131 PSF (Large Missile Impact) Installation Drawings # W15-74
The above maximum parameters do not occur simultaneously. See charts on installation drawings for combination of spans vs. loads.
Comparative analysis used X Yes No Mandatory Tests (Tested in accordance with AAMA 501/101/I.S.2/NAFS-02/TAS-202)
TEST DESCRIPTION TEST LOCATION REPORT DATE
TEST REPORT #
Test Sealed by
ASTM E283 Air Infiltration Leakage
Fenestration Testing Laboratory
04/23/2012 FTL-6678 Marlin D. Brinson, PE
ASTM E331 OR ASTM 547
& TAS 202
Water Penetration
Fenestration Testing Laboratory
04/23/2012 FTL-6678 Marlin D. Brinson, PE
ASTM E330 & TAS 202
Uniform Static Air Press.
Fenestration Testing Laboratory
04/23/2012 FTL-6678 Marlin D. Brinson, PE
Supplemental Tests (Tested in accordance with TAS-201 and TAS-203) TEST DESCRIPTION TEST LOCATION TEST
REPORT DATE
TEST REPORT #
Test Sealed by
FBC 1626.2 (TAS 201 & 203)
ASTM E1886/1996 ANSI Z97.1
Large Missile Impact & Cyclic
Level D/E
Fenestration Testing Laboratory
Blackwater Testing Inc
04/23/2012
04/06/2017 06/09/2017
FTL-6678
BT-ENI-16-003 BT-ENI-16-003B
Marlin Brinson, PE Constantin Bortes, PE
Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the above product conforms to the requirements of the 2017 Florida Building Code.
Evaluation Report Engineer: Javad Ahmad PE # 70592 Al-Farooq Corporation EB # 3538
This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements.
Sealed: 08/18/2017