revised proposal original proposal 200 …...2019/07/09 · 200 prince street 202 avenue of the...
TRANSCRIPT
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 91 TRASTUDIO
06/24/2019
ELEVATIONS - 200 PRINCE STREET
REVISED PROPOSAL ORIGINAL PROPOSAL
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 92 TRASTUDIO
06/24/2019
REVISED PROPOSAL
ELEVATIONS - 200 PRINCE STREET AND 202 AVENUE OF THE AMERICAS
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 93 TRASTUDIO
06/24/2019
ORIGINAL PROPOSAL
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 94 TRASTUDIO
06/24/2019
VIEW FROM PRINCE STREET, TOWARDS AVENUE OF THE AMERICAS
RENDERED VIEW 1 - PROPOSED
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 95 TRASTUDIO
06/24/2019
VIEW ACROSS 200 PRINCE STREET
RENDERED VIEW 2 - PROPOSED
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 96 TRASTUDIO
06/24/2019
VIEW FROM THE CORNER OF MACDOUGAL STREET AND PRINCE STREET
RENDERED VIEW 3 - PROPOSED
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 97 TRASTUDIO
06/24/2019
STRUCTURAL CONSULTANT
Consulting EngineersWEXLER & ASSOCIATES
FAX: (212) 643-227712 West 32nd St., 8th Floor . New York, NY 10001TEL: (212) 643-1500
Consultants:
Project:
Drawing Title
Seal & Signature
Date:
Scale:
Drawn By:
Page No:
Sheet No:
DOB Label
AS NOTED
00OF 11
ALL LEGAL RIGHTS INCLUDING BUT NOT LIMITED TO COPY RIGHT AND DESIGN PATENT RIGHTS IN THE DESIGNS, ARRANGEMENTS AND PLANS SHOWN ON THIS DRAWING ARE THE PROPERTY OF TRA STUDIO ARCHITECTURE, PLLC AND WERE DEVELOPED FOR USE SOLELY IN CONNECTION WITH THIS PROJECT. THIS DRAWING MAY NOT BE USED OR REUSED IN WHOLE OR IN PART, EXCEPT IN CONNECTION WITH THIS PROJECT, WITHOUT PRIOR WRITTEN CONSENT OF TRA STUDIO.
© COPYRIGHT 2018 TRA STUDIO ARCHITECTURE, PLLCALL RIGHTS RESERVED
NOT FOR
CONSTRUCTION
Mechanical/Electrical/Plumbing Engineer:
Structural Engineer:
TWIG CONSULTING ENGINEERS, PC111 W 33rd StreetNew York, NY 10001
6/24
/201
9 3:
49:3
1 PM
04-17-2019
AXON - 200 PRINCE ST
LPC-009.
NEW YORK, NY 10012
NORTH FACADE - 200PRINCE STREET
NO. DATE ISSUE
AXONOMETRIC - 200 PRINCE STREET
MATERIAL KEY:
EXISTING WALL TO REMAIN
FIXED WINDOW WITH BRONZE ANODIZED METAL FRAME
GLASS AND ALUMINUM DOOR
BRUSHED STAINLESS STEEL DOOR HANDLE
BRONZE ANODIZED ALUMINUM FASCIA
FACE BRICK TO MATCH EXISTING GLAZED WHITE BRICK AT 202 AVENUE OF THE AMERICAS
1
2
3
4
5
6
3
6
13
6
4
9
10
1
85
2
12
72
11
STUCCO FINISH OVER EXISTING BRICK WALL
GLASS AND BRONZE ANODIZED METAL GUARDRAIL
BRONZE ANODIZED METAL PLATE RETURN
GLASS AND POWDER-COATED METAL RAIL AT PARAPET
BRONZE ANODIZED ALUMINUM FRAME BIFOLD INSWING DOORS
BRONZE ANODIZED METAL BRACKET SIGN
UNGLAZED WHITE BRICK PILASTER, SET BACK 1 WHYTHE OF BRICK
7
8
9
11
12
13
10
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 98 TRASTUDIO
06/24/2019
2' -
1"7'
- 10
"1'
- 1"
3' -
6"
10' -
0"
3/4" REVEAL, CAULK RECESS WITH WEEPS
BRONZE ANODIZED ALUMINUM FRAMED BIFOLD
DOOR SYSTEM
GLASS AND BRONZE ANODIZED ALUMINUM FRAMED BALUSTER WITH METAL COPING CAP
EXISTING BRICK WALL FACE TO REMAIN AT 202 AVENUE
OF THE AMERICAS
FIXED SIDELITE
NEW INSULATED MASONRY WALL WITH GLAZED WHITE FACE BRICK TO MATCH EXISTING BUILDING AT 202 AVENUE OF THE AMERICAS
FIXED TRANSOM WINDOWS IN BRONZE ANODIZED ALUMINUM
FRAME
BRONZE ANODIZED ALUMINUM FRAMED DOOR WITH BRUSHED
STAINLESS STEEL HANDLE
BRONZE ANODIZED ALUMINUM FASCIA
PAINTED METAL PLATE RETURNS
BRONZE ANODIZED ALUMUNUM INFILL PANELS AT BULKHEAD
PAINTED METAL PLATE RETURNS
FIXED WINDOWS IN BRONZE ANODIZED ALUMINUM FRAME
UNGLAZED WHITE BRICK PILASTER, SET BACK FROM UPPER BRICK 1
WYTHE
BRACKET SIGN STAND-OFF, TYP.
UNGLAZED WHITE BRICK PILASTER, SET BACK FROM UPPER BRICK 1 WHYTHE
CONTINOUS HORIZONTAL PAINTED METAL PLATE
FIXED WINDOWS WITH BRONZE ANODIZED ALUMINUM FRAME
PROPERTY LINE
FIXED GLASS WINDOW PANES
GLASS AND BRONZE ANODIZED ALUMINUM FRAME DOOR, TYP.
ENCLOSE INTERIOR OF PILASTER WITH GYP. BD. SET BACK FROM PLATE, TYP.
EXISTING WALL AT 202 AVENUE OF THE AMERICAS. REPLACE FACE BRICK IN KIND.
BIFOLD DOORS 4x EQUAL LEAFS
GLASS AND BRONZE ANODIZED ALUMINUM FRAME DOOR, TYP.
EXTERIOR PATIOEGRESS 202
AVENUE OF THE AMERERICAS
1 1/2"20' - 1 3/8"
1 1/2"
2' - 4 5/16"
1 1/2"
14' - 9 1/2"
1 1/2"
2' - 4 5/16"1 1/2"
RECESSED UNGLAZED WHITE BRICK PILASTER
3 5/
8"
3 5/
8"
PAINTED STEEL PLATE
PAINTED STEEL PLATE TO FRAME PILASTER.
BRONZE ANODIZED ALUMINUM DOOR SADDLE BETWEEN VERTICAL PLATES RECESSED UNGLAZED
WHITE BRICK PILASTER
TO G
LASS
1' -
6"
HO
L D1'
- 6"
1' -
6"
SCALE: 1/2" = 1'-0"1 PROPOSED ENTRANCE- 200 PRINCE - ENLARGED ELEVATION
10/24/18200 PRINCE STREET & 202 AVENUE OF THE AMERICAS
NORTH FACADE - 200 PRINCE STREETLX-11
SCALE: 1/2" = 1'-0"2 PROPOSED ENTRANCE -200 PRINCE - ENLARGED PLAN
B A C9 9 9
200 PRINCE STREET & 202 AVENUE OF THE AMERICAS SHEET NO OF 99 TRASTUDIO
06/24/2019
DROPPED GYP. BD. CEILING
NEW INSULATED MASONRY WALL WITH FACE BRICK TO THE EXISTING BUILDING
AT 202 AVENUE OF THE AMERICAS
TYPICAL FIXED WINDOW WITH BRONZE ANODIZED ALUMINUM FRAME
3/4" REVEAL BETWEEN MASONRY AND METAL PLATE. TO BE CAULKED WITH
WEEPS
1 1/2" THICK PAINTED METAL FLAT PLATE TO ALIGN WITH FACE BRICK ABOVE
CONCEALED DOWNLIGHT LED FIXTURE
ALUMINUM CLAD FASCIA BAND, INSULATED
RETAIL SPACE
INTERIOR FINISH FLOOR
FIXED WINDOW TRANSOM WITH BRONZE ANODIZED ALUMINUM FRAME
RETAIL SPACE
10"
11 1
/2"
1 1/
4"
BRONZE ANODIZED METAL FIN FRAME AROUND OPENING
METAL AND GLASS ENTRY DOOR(OFFSET GLAZED THERMAL)
4"
CONTINOUS PAINTED METAL RETURN FIN AT DOOR OPENING TO ALIGN
WITH FACE BRICK
BRONZE ANODIZED ALUMINUM DOOR SADDLE
TO GLASS FACE1' - 6"
PAINTED METAL PLATE TO FRAME STOREFRONT (BEYOND)
CONCRETE PAVERS
ALIG
N W
ITH
BU
LKH
EAD
2' -
4"
INSULATED REINFORCED CONCRETE ROOF
1' - 9 3/4"
TERRACE
RETAIL SPACE
10"
4"
1 1/
4"
11 1
/2"
3 1/
2"1'
- 10
1/2
"2
1/4"
7' -
6 11
/16"
2 5/
8"1
1/2"
2 5/
8"
2' -
11 5
/8"
2 5/
8"
1" TEMPERED GLASS RAILING
CONCEALED DOWNLIGHT LED FIXTURE
ALUMINUM CLAD FASCIA BAND, INSULATED
BRONZE ANODIZED ALUMINUM DOOR SADDLE
INSWING FOLDING DOORS WITH BRONZE ANODIZED ALUMINUM
FRAME
ALUMINUM PROFILE BOTTOM RAIL - ALIGN WITH BULKHEAD
AT ADJACENT FIXED WINDOWS
TO GLASS FACE1' - 6"
PAINTED METAL PLATE TO FRAME STOREFRONT (BEYOND)
HO
LD3'
- 6"
DROPPED GYP. BD. CEILING
NEW INSULATED MASONRY WALL WITH FACE BRICK TO THE EXISTING BUILDING
AT 202 AVENUE OF THE AMERICAS
3/4" REVEAL BETWEEN MASONRY AND METAL PLATE. TO BE CAULKED WITH
WEEPS
1 1/2" THICK PAINTED METAL FLAT PLATE TO ALIGN WITH FACE BRICK ABOVE
ALUMINUM CLAD FASCIA BAND, NOTCH INTO FACE BRICK AT PILASTER
RETAIL SPACE
INTERIOR FINISH FLOOR
RETAIL SPACE
CONTINOUS PAINTED METAL RETURN FIN (BEYOND) AT END OF BUILDING
3 5/8"
STRUCTURAL STEEL COLUMN TO SUPPORT NEW NORTH WALL
WHITE UNGLAZED FACE BRICK PILASTER TO ENCLOSE STEEL COLUMN.
SET BACK FROM UPPER BRICK, APPROXIMATELY (1) WYTHE
GYPSUM BOARD WALL FINISHING AT INTERIOR
06/21/19200 PRINCE STREET & 202 AVENUE OF THE AMERICAS
NORTH FACADE - 200 PRINCE STREETLX-11A
SCALE: 1" = 1'-0"A PROPOSED SECTION AT ENTRY DOORSCALE: 1" = 1'-0"C PROPOSED SECTION AT BI-FOLD DOORS
SCALE: 1" = 1'-0"B PROPOSED SECTION AT ENTRY DOOR