Retrofit Standards for External and Cavity Wall Insulation
Robin Byrne
Certification & Inspection Officer, NSAI
Overview
• Background
• S.R. 54:2014
• External Insulation
• Cavity Wall Insulation
Background
• NSAI Agrément Certification• Set up in 1987
• Relates to design and fitness for use of a product/system
• Compliance with Irish Building Regulations
• Confirm durability in Irish conditions
• Installation
Background
• NSAI Agrément Installer Schemes:• Set up where quality of installation plays
large part in end performance of product
• External wall insulation (130 installers)
• Full fill cavity wall insulation (139 installers)
• Added confidence to homeowner for work conducted as product & installer both independently & regularly audited
• Primary certification & preferred guidance for SEAI grant scheme
Background
• NSAI Agrément Installer Schemes:
• Scheme documents outline responsibilities for Cert holder, Installer and NSAI
• Training, documentation, storage, product traceability, site work, photos, homeowner’s manual
• Registration & surveillance audits
S.R. 54:2014
• Technical guidance on:
• Energy efficient retrofit
• Application of retrofit measures
• General building science
• Management of retrofit projects
• Based on the most recent standards and technical guidance
S.R. 54:2014
• Deals with building fabric and services
• Typical existing construction/installation
• Appropriate retrofit measures
• Detailed design issues for each measure
• Detailed installation considerations for each measure
S.R. 54:2014
• Examples of design considerations:
• Disruption to occupants
• Adaptation of roof lines
• Public footpath encroachment
• External services
• Impact resistance
• www.standards.ie
Other Standards
• prEN 16809-1• Specification for bonded and loose-fill
EPS insulation products before installation
• prEN 16809-2• Specification for bonded and loose-fill
EPS insulation products after installation
• Your Standards Your Say www.nsainep.ie
External Insulation
• Potential issues:• Thermal bridging
• Roof line not extended
• Ventilation
• Penetrations not sealed
• Guttering
• Maintenance
• Services: Cables, meter boxes
External Insulation
• Potential issues:• No fire barrier installed
• Use of renders in cold weather
• Use of uncertified materials
• Impact resistance
• Documentation:• Insufficient records/photos
• No product traceability
30/03/2011 NSAI Agrément Certification Schemes
Full Fill Cavity Wall Insulation
• Restrictions:• Building must be at least 3 years old• 40mm minimum existing cavity width• No signs of dampness on inner face of
outer leaf• Fair-faced block work not suitable• Fair-faced brickwork with tool flush
joints• Electric cables must be sheathed
Exposure Zones
• Normal:• Impervious cladding
and rendered walls up to 12m in height
• Fair faced unrenderedbrickwork with tooled flush joints up to 2 storeys in height
• Severe:• Unrendered brickwork
is not suitable
Full Fill Cavity Wall Insulation
• Potential issues:• Wrong drill pattern• Insufficient examination of existing
cavity• Ventilation• Unsuitable construction• Unsuitable location• Existing partial fill
24/06/2009 NSAI Agréme
nt –Product Standa
rds & Retrofit