Release Notes ResolutionMD® is a zero-footprint enterprise viewing platform installed in healthcare facilities worldwide. These release notes apply to release 6.4 and any subsequent maintenance and patch releases, and include the release history for versions 5.3 and up. Last Updated:2019/06/20 Confidential and Proprietary

Upload: others

Post on 14-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

Release Notes

ResolutionMD® is a zero-footprint enterprise viewing platform installed in healthcare facilities

worldwide.

These release notes apply to release 6.4 and any subsequent maintenance and patch releases, and

include the release history for versions 5.3 and up.

Last Updated:2019/06/20

Confidential and Proprietary

Page 2: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)2

Table of Contents

Maintenance Releases 4

New Features, Changes and Fixes 8

Supported and Compatible Components 12

End of Life and Discontinued Support Notice 17

Known Issues and Recommendations 18

Release History 27

Release 6.3.1 27

Release 6.3.0 27

Release 6.2.3 30

Release 6.2.2 31

Release 6.2.1 31

Release 6.2 31

Release 6.1.1 40

Release 6.1 41

Release 6.0.2p5 44

Release 6.0.2p4 45

Release 6.0.2p3 45

Release 6.0.2p2 46

Release 6.0.2p1 48

Release 6.0.2 48

Release 6.0.1 49

Page 3: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)3

Release 6.0 49

Release 5.4.2p1 57

Release 5.4.2 57

Release 5.4 59

Release 5.3.3 (iOS Client Only) 59

Release 5.3.3 (Android Client Only) 60

Release 5.3.2 60

Release 5.3.1 60

Release 5.3 61

Page 4: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)4

Maintenance Releases

This section provides information about maintenance releases issued following ResolutionMD 6.4.0.

Release 6.4.6

2019/06/21

The 6.4.6 maintenance release provides enhancements specific to integrations with IVS, one of our

partner's proprietary service, as well as documentation changes.

Corrections and Modifications

n Added support for a new security interface for IVS. (AVA-714)

n Updated the company address in the documentation, to reflect the new location of our corporate

headquarters. (RTD-1035 and RTD-1039)

Release 6.4.5

2019/06/07

The 6.4.5 maintenance release implements new features and bug fixes specific to integrations with

IVS, one of our partner's proprietary service.

Corrections and Modifications

n Enhanced availability of login information: when integrated with the IVS service, the iOS and

HTML5 clients will display the site name that the clinician is currently logged into (AVA-590) and

acquire the information about the currently logged-in user from the IVS system. (AVA-694)

n Increased performance when querying data from integrated VIX systems. (AVA-615)

n New configurable default values on the server for the “Modality” and the “DateWithin” search

parameters, for both the iOS and HTML5 clients. (AVA-698)

n Updates to the ResolutionMD-VA branded iOS native app: it is now built using Xcode 10

(RMDIOS-1225), and there is a new icon for the app. (AVA-699).

Page 5: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)5

n Improvements to the style and wording of the error messagemodal dialog boxes in the HTML5

client, for enhanced readability and clarity. (AVA-697)

n Updated the generic error message in the IVS configuration.xml file. (AVA-710)

n Fixed logmessage formatting issues in the ava.log file. (AVA-696)

n Added a logmessage to indicate specifically situations where users end their session by closing

the web browser or tab rather than log off the system properly. (AVA-712)

n Fixed an issue in IVS system integrations where the username entry was no longer using both

the first and last names. (AVA-692)

n Fixed a scrolling issue that would sometimes occur when viewing reports in the HTML5 client on

Android devices. (RESMDHTML-7506)

Release 6.4.4

2019/04/02

The 6.4.4 maintenance release implements workflow improvements specific for a peer review system

integration.

Corrections and Modifications

n Added a configuration option which allows server administrators to enable/disable the use of

related-study search parameters for query operations and for filtering returned results. (RMD-

25681)

n Improved display of default window/level values for any DICOM data that has valid VOI LUT

DICOM tags. (RMD-25671)

Release 6.4.3

2019/02/28

The 6.4.3 maintenance release implements new features and bug fixes specific to integrations with

IVS, one of our partner's proprietary service.

Page 6: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)6

Corrections and Modifications

n The ResolutionMD server now supports authentication using JSON Web Tokens (JWT). (AVA-

577)

n The use of the IVS service and can be enabled/disabled through a configuration option. (AVA-

687)

n IVS-specific logs now contains messages indicating how long each users is logged in, to

facilitate themonitoring of server usage. Alsomade a few other small improvements to the log

files. (AVA-672, AVA-558, and AVA-640)

n Properties were added to the IVS-specific configuration files to support the new features. (AVA-

686)

n Users connecting to the IVS service on iOS devices now get presented with a landing page in

their web browser, where they can choose to continue in the browser or launch the native iOS

app if previously installed. (AVA-616)

n Removed the libswiftRemoteMirror.dylib package from unsigned iOS builds, as it was

creating issues when submitting to the app store. (RMDIOS-988)

Release 6.4.2

2019/02/05

The 6.4.2 maintenance release incorporates bug fixes.

Corrections and Modifications

n Resolved issues reported from the field:

n It is now possible to configure the Instance level C-FIND workflow (for loadingmultiframe

studies) on a per-modality basis. (RMD-25016)

n Applying a blacklist modality filter to a DICOM repository no longer prevents the

application from retrieving and displaying SR and PDF reports in a loaded study’s worklist

entry. (RMD-25494)

n Fixed an issue where log files were no longer being saved as compressed files every

night. (RMD-25569)

Page 7: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)7

n Other corrections andmodifications:

n The date format configured by the system administrator is now displayed directly in the

client user interface instead of in a pop-upmessage, eliminating the need for the users to

dismiss the pop-up notifications. (RESMDHTML-7406, RMDIOS-1133)

Release 6.4.1

2018/10/31

The 6.4.1 maintenance release incorporates bug fixes.

Corrections and Modifications

n Resolved issues reported from the field:

n In some edge cases, it was possible for end users to perform searches even though the

Restricted URL option had been enabled on the server. This would only occur after a

related studies search, and only if the product window was sized such that the search

form was displayed as a tab. (RESMDHTML-7203)

n When using the Cine feature in Internet Explorer (IE), achieving a target of 60 frames-per-

second (FPS) is difficult because of how this browser handles memory. In this release,

wemade some changes to how Cine is rendered in IE, and performance is now close to

the target FPS of 60. (RESMDHTML-7281)

n Added support for querying/retrievingmulti-frame datasets from PACS repositories that

share a StudyInstanceUID for a single study. (RMD-25065)

n In MIP/MPR view mode on web-based clients, the "U" keyboard shortcut was not

working as expected: it was removing theMPR axes when pressed the first time, but it

was not restoring them when pressed a second time. (RESMDHTML-7253)

n Other corrections andmodifications:

n Added support for the newest Report API MckessonMR PACS released with version

12.4. (RMD-24516)

n It is now possible to print RIS reports coming fromMckessonMR PACS. Previously,

these reports were displayed inmodal windows, which do not support printing. (RMD-

24835)

n Improved the workflow on the native iOS client when the Single Patient Context setting is

enabled. (RMDIOS-1107).

Page 8: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)8

New Features, Changes and Fixes

Release 6.4

2018/08/31

Release 6.4 of the ResolutionMD product has new features that are driven by the industry’s demands

in the enterprise imaging space.

New in this Release

Client updates

Please note that the Android native app, which had reached end of life in earlier releases, is no longer

supported. Before upgrading the server to release 6.4.0, please notify all users of the Android native

app that they must now use the HTML5 viewer, which is accessible directly from a browser on their

Android device.

Note also that the iOS native app must be upgraded to the 6.4.0 version. Any user who had disabled

the auto-update feature will need to manually upgrade their app.

n HTML5 client:

n The search interface now provides a bi-directional sort indicator.

n Key Objects (KO) and DICOM Key Image Notes (KIN) objects are now supported.

n New significant findings navigation functionality. If the loaded DICOM dataset has

GSPS, CSPS, KO or KIN objects associated with the study, clinicians are presented with

navigation controls allowing them to quickly navigate to these elements within a given

series.

n Users running the client on iOS 11 devices can now take advantage of the audio/video

conferencing capabilities.

nn HTML5 and Flex clients:

n Web-based clients can now query and retrieve scanned documents fromMcKesson

Radiology PACS.

n HTML5 and iOS clients:

n DICOM encapsulated videos are now supported. Note that nometadata is shown during

video playback.

Page 9: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)9

n Dates can now be displayed in either yyyy-MM-dd or dd-MM-yyyy format, depending on

the configuration set by the system administrator.

Note that for the iOS client, the date format set by the system administrator determines

how the dates are presented in the search results, but the format of the date in the

search input fields is determined by the settings on the user's device.

n iOS client:

n It is now possible to configure the client so that only a single patient can be displayed at a

time; patient context is based on the PatientID field.

n Users can now access and play non-DICOM audio files (.mp3 and .m4a files).

Security and administration features and updates

n Updated the hardware and scalability specifications. See the ResolutionMD Server

Recommendations & Minimum Hardware Requirements document for more information.

n Supported version of the Java Development Kit (JDK) is now 1.8u171.

n Updated the version of TokBox to 2.14.0 (TokBox is used for the audio/video collaboration

feature).

Regulatory updates

n The user guides for Hong Kong and Singapore contain the new unified "Indications for Use"

statement to reflect the updated device registration. The unified IFU statement is the same as

the previously implemented USA FDA statement.

n The HTML5 user guides for Hong Kong and Singapore are now each a single document that

replaces the Desktop and Touchscreen guides.

Standards updates

n Expanded DICOMmodality support to include DICOM encapsulated videos (HTML5 and iOS

native clients only).

Mobile devices updates

n The validatedmobile devices list has been expanded to include:

n iPhone 8

n iPhone X

n iPad Pro 10.5”

Page 10: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)10

n The Android native app is no longer supported. See the End of Life and Discontinued Support

Notice section for more information.

Please consult our website at the following address for updates to the list of supported devices:

www.calgaryscientific.com/validated-device

Operating system updates

n Wehave validated the installation and operation of the ResolutionMD product onWindows

Server 2016.

GPU updates

n Wehave validated the installation and operation of the ResolutionMD product with NVIDIA

Quadro P4000GPUs. See the ResolutionMD Server Recommendations & Minimum Hardware

Requirements document for up-to-date GPU support information.

Documentation updates

User guides:

n Updated the content to reflect new features added in 6.4.

n Updated the Unique Device Identification (UDI) codes for traceability.

Server-side documentation:

n Added sections in the Server Deployment and AdministrationManual to include the configuration

steps for the new features added in 6.4, along with some general improvements.

n Updated the DICOMConformance Statement to reflect new support for DICOM encapsulated

videos.

Corrections

Issues reported from the field

n The application was not removing the hyphens from the values for MRN/PatientID before

performing search queries. (RMD-24797)

n When performing a URL launch into the Flex client, the server would query for thumbnails even if

the Flex client was configured to not query for them. (RMD-24673).

Page 11: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)11

n PDQmessages were not handled gracefully in the HL7 version 2.5 because of compatibility

issues. (RMD-24134)

n The Play button image was displaying on top of the video when playback was paused. (RMD-

23810)

Issues discovered and fixed internally

n Found and fixed a collection of minor translation issues discovered in the User Guides.

n Fixed a collection of minor translation issues discovered in the User Interface.

n GSPS and Key Object indicators were not being properly rendered when being retrieved from a

IIMS repository. (RMD-24798)

Previously known issues that have been fixed in 6.4

n When using Russian, Turkish or Japanese character keyboards, the hotkeys for the orientation

labels were not working properly. (RTD-528)

n When running the client in Google Chrome, the Vietnamese user guide would not display. (RMD-

24554)

Page 12: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)12

Supported and Compatible Components

This section provides the latest information regarding operating systems, devices, browsers and

language support.

Server

Supported server operating systems

n Physical server: Red Hat Enterprise Linux (RHEL) 6.9, Windows Server 2016 Standard

n Virtualized solutions: RHEL 6.9, Windows Server 2016

Server virtualization

n 2D CPU-Only VM

l OS: RHEL 6.9

l Host: ESXi versions that support Hardware Version 10 (ESXi 5.5, 6.0 and 6.5)

n GPU Passthrough VM

l OS: RHEL 6.9 (OVA template available), Windows Server 2016

l Host: ESXi versions that support Hardware Version 10 (ESXi 5.5, 6.0 and 6.5) running with

supported GPU cards.

Browsers

HTML5 client on Windows

n Internet Explorer 11, Chrome (Current), Firefox (Current)

Flex client on Windows

n Internet Explorer 8, 9, 10, 11, Chrome (Current), Firefox (Current)

HTML5/Flex clients on MacOS

n Safari (Current), Chrome (Current), Firefox (Current)

Page 13: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)13

HTML5 client on iOS mobile devices

n Mobile Safari for iOS 11

n Mobile Safari for iOS 10

HTML5 client on Android devices

n Chrome (Current)

NOTE: “Current” in the list of browsers above indicates that the automatic update default setting is

supported. The minimum browser versions required are Chrome v42 (Windows/Mac), Chrome v59

(Android), FireFox v35, Safari v6, and Mobile Safari v10.

Validated Devices and Operating Systems

ResolutionMD Mobile Native iOS Clients

The ResolutionMD Mobile iOS client can be downloaded from the iOS App Store.

The mobile devices validated for use are as follows:

iOS devices running iOS 10 or 11

n iOS phones: iPhone 5*, iPhone 5S, iPhone 6, iPhone 6 Plus, iPhone 6S, iPhone 7,

iPhone 7 Plus, iPhone 8, iPhone X

n iOS tablets: iPad 4*, iPad Air, iPad Air 2, iPad Mini*, iPad Mini 2, iPad Mini 3, iPad Pro (9.7"),

iPad Pro (10.5"), iPad Pro (12.9")

*iOS 10 only, as iOS 11 is not supported on these older devices

Page 14: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)14

ResolutionMD HTML5 Client

The ResolutionMD HTML5 client is a zero-footprint client that has been validated on the following

mobile devices:

iOS devices running iOS 10 or 11

n iOS phones: iPhone 5*, iPhone 5S, iPhone 6, iPhone 6 Plus, iPhone 6S, iPhone 7,

iPhone 7 Plus, iPhone 8, iPhone X

n iOS tablets: iPad 4*, iPad Air, iPad Air 2, iPad Mini*, iPad Mini 2, iPad Mini 3, iPad Pro (9.7"),

iPad Pro (10.5"), iPad Pro (12.9")

*iOS 10 only, as iOS 11 is not supported on these older devices

Android devices running Android 5.1, 6.0 or 7.0

n Android phones: Samsung Galaxy S5*, Samsung Galaxy S7, Samsung Galaxy S8

n Android tablets: Samsung Galaxy Tab 2 10.1, Samsung Galaxy Tab S, Samsung Galaxy Tab

S2.

Please consult our website at the following address for updates to the list of supported devices:

www.calgaryscientific.com/validated-devices

Languages

Software and user guides

German, English, Spanish, French, Italian, Japanese, Korean, Portuguese, Russian, Turkish,

Simplified Chinese, Traditional Chinese

User guides only

Vietnamese

Page 15: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)15

Server and Client Application Compatibility Matrix

The following tables summarize compatibility between the various releases of the ResolutionMD

client and server.

Note that all partners are expected to upload the mobile apps to the App Store in advance of upgrading

any servers to the 6.4 release.

It is also highly recommended that users keep their client app up-to-date.

Compability between latest client and older servers

Server Version 6.4 iOS Client

6.4 A

6.3 B

6.2 B

6.1 B

6.0 B

5.3 B

A: Full compatibility with all features supported across all platforms.

B: Client applications will operate against the older server, but new functionality is not available. The

following message is displayed: "Warning: Older Server. The server is older than this mobile client.

Some client functionality may be unavailable."

Page 16: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)16

Compatibility between older clients and latest server

Client

Version

(Android)

Client

Version

(iOS)

6.4 Servers

- 6.4 yes

- 6.3 no

6.2 6.2 no

6.1 6.1 no

6.0 6.0 no

5.3 5.3 no

Page 17: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)17

End of Life and Discontinued SupportNotice

This section documents features that are nearing end of life or no longer supported in this software.

Discontinued

The following were end of life in previous releases and are not supported in 6.4:

n Android nativemobile app

The app will not connect to ResolutionMD 6.4 servers. To continue using the product on Android

phones or tablets, users can run the HTML5web client, which is accessible directly frommobile

web browsers (see the Browsers section under "Supported and Compatible Components").

Deprecated

The following will not be supported beyond ResolutionMD 6.x:

n Flex client.

Partners should be moving to the HTML5 viewer, which now brings a much richer feature set

and does not require any Adobe Flash plugin.

Page 18: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)18

Known Issues and Recommendations

The table below lists known issues that are applicable to the 6.4 release:

Component Issue Description Since

Server

The user is not notified if a dataset only

gets partially loaded due to an loading

error. (RMD-18925)

6.0

URL integration

When doing a secure URL launch using

the accession number as the query

parameter, the viewer will generate a

redirect URLs to retrieve any additional

reports, series and thumbnails. These

redirects calls, results in displaying the

StudyInstanceUID and the

SeriesInstanceUID values in plain text in

the logs files and when using the Network

console of the web browser developer

tools. (RMD-20059)

6.0

Page 19: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)19

Minor Issues

The following minor issues are also known to exist:

Component Issue Description Since

HTML5 client

The chevron indicator in the search

results, used to expand the series within a

study, is not being displayed properly in

the HTML5 client on Internet Explorer 11.

(RESMDHTML-7197)

6.4

HTML5 client

When running the client in Internet

Explorer 11, if a .png image is manually

changed to an image with a different file

extension, the browser will not display

this image because the image encoding

and file extension will not match. Other

web browsers are to be able to display

these files without issue. (RESMDHTML-

6973)

6.3

HTML5 client

When running the client on Internet

Explorer 11, using the Cine function with

very large (2000+ slices) data sets will fail

if the browser memory exceeds 1.5 GB. If

using Cine with large data sets is a

required workflow, the recommended

workaround is to reduce the size of the

image viewer window. (RESMDHTML-

5995)

6.2

Page 20: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)20

Component Issue Description Since

HTML5 client

When running the client on an Android

device, in collaboration sessions, if a

participant selects a 3D preset, the host

will not see which preset has been

selected from the preset menu. (RMD-

23178)

6.2

HTML5 client

When running the client on an iOS

device, if the end user launches a

second URL link after clearing the

cache, the application may display a

prompt to provide login credentials.

(RMD-23165)

6.2

HTML5 client

When running the client on a touchscreen

device, in a collaboration session, if the

host/participant is interacting with the

viewer, the user on the HTML5 viewer

can still pan/zoom/use the scrub bar.

(RESMDHTML-6372)

6.2

HTML5 client

If a SOP class (such as CT or MR) which

contains a large number of images in a

series is added to be ungrouped and it

results in over 400 thumbnails, the

HTML5 client will not handle this well.

(RMD-23032)

6.2

iOS native app

The "Unsupported Data" message no

longer appears when viewing BMP

images. (RMDIOS-686)

6.2

Page 21: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)21

Component Issue Description Since

iOS native app

The app does not log out of the server

when the connection times out. (RMD-

21675)

6.2

Flex client

TheDate Time field is returned as empty

when retrieving non-DICOM data from

the Synapse VNA. (RMD-22744)

6.2

Server

configuration

When configuring an XDS integration, if

an XDS connection has been added as

an integration, the server administrator

must set the display_error_dialog

parameter in the configuration.xml file

to true. Otherwise, if the HTML5 viewer

is still running in study-centric GUI, an

error message will be displayed to the

user. (RESMDHTML-6402)

6.2

HTML5 client

Drag and drop is not supported for

encapsulated PDFs, the user must

double click on the report to visualize it

properly. (RESMDHTML-5856)

6.1

iOS native app

The app included in the 6.1 and 6.0

releases is not able to activate the AV

button when connecting to an older 5.3.2

server. (RMDIOS-528)

6.1

Server upgrade

When upgrading from 4.3.2 to 6.1.0, the

configuration.xml file must be

installed on the 4.3.2 server in order for

the upgrade to succeed. (RMD-21738)

6.1

Page 22: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)22

Component Issue Description Since

HTML5 client

When running the client onmobile Safari,

if an end user minimizes the applications

to work with another program and doesn’t

return to the ResolutionMD application

before the client activity timeout, the

followingmessage will be displayed:

"Connection to the imaging session was

lost due to a network error". Once the

message is dismissed, the end user will

be logged out and all current work will be

lost. (RMD-17412)

6.0

Flex client

Repeatedly dragging and dropping images

and videos into amulti-view layout can

cause the client to crash. This will only

happen when alternating between images

and videos, and only after a number of

users load a number of images/videos.

(RMD-20302)

6.0

HTML5 client

When using multi-monitor, if an end user

continuously performs wide-open

wildcard, the child window can end up in

a “hung” state and can get out of sync

with the primary window. The user can

recover from this state by logging out of

and back into the server.

(RESMDHTML-4467)

6.0

Page 23: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)23

Component Issue Description Since

HTML5 client

When running the client on mobile Safari

on iOS 10, opening new tabs windows

may trigger a "Network Connection" error

message. Upon dismissing the error,

users will need to log back into the server

and all current work will be lost. (RMD-

20252)

6.0

HTML5 client

When running the client on an iOS

device, in a collaboration session,

participants viewing in split view may not

be able to see MP4 video in the set

viewport. (RESMDHTML-1990)

6.0

HTML5 client

When running the client on Firefox, in a

multi-monitor setting, if the pop-up

blocker is not initially disabled and the

end user tries to reload a previously

saved multi-monitor setup then disables

the pop-up blocker, two windows will

open up instead of just one.

(RESMDHTML-4323)

6.0

HTML5 client

When running the client on Internet

Explorer 11, in a multi-monitor setting

with the child window maximized on the

second monitor, if the user closes and

reopens the child window, the browser

may not resize/reposition child window

properly. (RESMDHTML-4324)

6.0

Page 24: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)24

Component Issue Description Since

HTML5 client

When running the client on Internet

Explorer 11, if an unbounded search

returns a large amount of data, the

activity spinner will freezes, however the

requested datasets will be returned to the

search results. (RESMDHTML-4980)

6.0

HTML5 client

When running the client on an iOS

device, if using the measurement loupe

tool to measure or annotate a 3D image,

users won’t be able to rotate the study

and add a measure or annotation.

(RESMDHTML-4946)

6.0

HTML5 client

When using multi-monitor, if the end user

loads data using a drag-and-drop gesture

while a child window was already

spawned, the metadata and orientation

labels becomemassive. Resize the

window to correct the display.

(RESMDHTML-4750)

6.0

HTML5 client

In 3D mode, when placing a text

annotation, the text box does not appear.

The user must select the text annotation

again to open the text box.

(RESMDHTML-5041)

6.0

HTML5 client

When hovering over the date of birth

calendar button, the tooltip does not

display. (RESMDHTML-5113)

6.0

Page 25: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)25

Component Issue Description Since

HTML5 client

When collaborating on a non-DICOM

dataset, from time to time the dataset

may appear panned or zoomed.

Resetting the view resolves this issue.

(RESMDHTML-4924)

6.0

HTML5 client

When collaborating on a non-DICOM

dataset, only the collaboration host will

see the metadata; it will not be visible to

the participants. (RMD-20142)

6.0

HTML5 client

Cannot get to MIP/MPR (or 3D) view

after closing a study in MIP/MPR or 3D.

(RESMDHTML-4987)

6.0

HTML5 and Flex

clients

In a collaboration session, the host and

participants can become out of sync

when viewing non-DICOM images on

different clients (Flex/HTML5) as not all

formats are supported in all clients.

(RMD-16625)

6.0

HTML5 and Flex

clients

When URL launching to a report into the

Flex or HTML5 client, the associated

patient study will load into the StudyList,

however the user will need to select the

report to load it into a modal window.

(RMD-17357)

6.0

Page 26: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)26

Component Issue Description Since

Flex client

Whenmultiple studies are loaded and

linked scrolling is enabled, a series with

KO dataset may cause scrolling in other

series. (RMD-19296)

6.0

iOS native app

When loading two studies that have the

same StudyInstanceUID from two

different PACS, only the first dataset will

load. The second study will be displayed

in the search results but the end user

won’t be able load the study into the

image viewer. (RMDIOS-354)

6.0

iOS native app

In a collaboration session, participants

cannot add text annotations. (RMDIOS-

336)

6.0

iOS native app

Closing the modality selection view

returns to the search menu as 'any'

selected, but still only searches with last

selected modality. (RMD-11088)

6.0

Page 27: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)27

Release History

This section summarizes new features, enhancements, and corrections for releases 5.3 and above. It

is presented in reverse chronological order.

For information about releases before 5.3, see the release notes for those releases.

Release 6.3.1

2018/04/10

The 6.3.1 maintenance release incorporates a minor fix allowing for the querying and retrieval of

reports-only patient data within the IIMS systems.

Corrections and Modifications

n Addressed an issue where patient datasets containing only reports would not be displayed when

the server is integrated with the IIMS system. The server will now query for these patient

datasets and display them as expected (RMD-24237). This setting can be configured within the

IIMS plugin (RMD-24287).

Release 6.3.0

2018/02/26

Release 6.3 of the ResolutionMD product has new features that are driven by the industry’s demands

in the enterprise imaging space.

New in this Release

Client updates

n All clients

n Added support for use and configuration of RESTful web services when integrating with a

Synapse VNA system.

Page 28: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)28

n HTML5 client

n Image printing: users can now print images from the image viewer.

n PDF reports: PDF reports retrieved from DICOM or non-DICOM repositories are now

rendered in the viewport of the image viewer.

n Worklist filtering: users can now filter the worklist by modality or by study date.

n Non-DICOM audio files: users can now query, retrieve and play .mp3 and .m4a files.

n iOS client

n New workflows for proprietary IIMS integrations for our Mayo partner:

n Restricted exams: A new workflow has been introduced to clearly identify

restricted exams, and prompt users to re-authenticate and provide reason for

access before they can view the content.

n Sensitive exams: There are now visual cues in the search results to clearly identify

sensitive exams, and a warning is displayed to remind users to check their work

environment before viewing the content.

n VIP patients: The ResolutionMD product now integrates with an external VIP

authorization service, and users who wish to view the dataset for a VIP patient

must be authorized with this service.

n Added support for the auto-related studies configuration.

Security and administration features and updates

n Updated the hardware and scalability specifications. See the ResolutionMD Server

Recommendations & Minimum Hardware Requirements document for more information.

Regulatory updates

n There were no updates to the Regulatory status of the ResolutionMD product.

Standards updates

n There were no updates to the standards used in the ResolutionMD product.

Mobile devices updates

n No new mobile devices were validated for this release. Please consult our website at the

following address for updates to the list of supported devices:

www.calgaryscientific.com/validated-device

Page 29: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)29

Operating system updates

n Wehave validated the installation and operation of the ResolutionMD product with Red Hat

Enterprise Linux (RHEL) 6.9.

GPU updates

n There were no updates to the validated GPU cards list. See the ResolutionMD Server

Recommendations & Minimum Hardware Requirements document for up-to-date GPU support

information.

Documentation updates

User guides:

n Updated the content to reflect new features added in 6.3.

n Updated the Unique Device Identification (UDI) codes for traceability.

n The product version now includes a third digit, to better indicate when a server has been

updated.

Server-side documentation:

n Added sections in the Server Deployment and AdministrationManual to include the configuration

steps for the new features added in 6.3, along with some general improvements.

n Fixed someminor typos in the DICOM conformance statement.

Corrections

Issues reported from the field

n When upgrading onWindows servers, there were sometimes issues with migrating SSL

certificates if the product had been installed on drives other than the C: drive. (RMD-23307)

Issues discovered and fixed internally

n Using special characters in the connection namewhen configuring Synapse VNA connections

would throw an exception. (RMD-20792)

n The upgrader script was not copying the SSL certificates used for mutual SSL. (RMD-23106)

Page 30: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)30

n In rare occasions, the GSPS overlays would not load, or would cause the application to crash.

(RMD-23465)

n When loading non-DICOM images, the load state would not get updated if the load was

interrupted. (RMD-24055)

n Users were not able to log in if the username contained leading or trailing spaces. (RMDIOS-793)

n When upgrading from 5.x to 6.x, there were sometimes issues if the conf directory did not

contains a ssl folder. (RMD-24145)

n On the iOS client, the Referring Physician value is now displayed without the ^ character.

(RMDIOS-705)

Previously known issues that have been fixed in 6.3

n Unable to configuremandated access rules when LDAP over SSL is used. (RMD-16651)

n The logback.xml syslog appender fails when addingmore then one log file to the log file;

appendedmessages won’t include the log filenamewhere themessage was generated from.

(RMD-20324)

n When using the HTML5 viewer on an Android device, the double tap and drag gesture, used to

change the window/level setting, is sometimes unresponsive. (RMD-23193)

n Multitenancy does not support patient-centric searching and XDS integration. (RMD-23245)

n When upgrading, the configured searchablemodalities aremigrated following the upgrade;

however, newly supportedmodalities will not be included in the configuration file and will need to

be addedmanually. (RMD-23308)

Known Issues

No new Sev0, Sev1 or Sev2 defects were identified for the 6.3 release.

Release 6.2.3

2018/09/14

This release did not contain new features or corrections. Modifications were limited to updating

branding information for partners.

Page 31: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)31

Release 6.2.2

2018/06/05

The 6.2.2 maintenance release resolved an issue reported from the field regarding the grouping and

display of single-frame instances for multi-frame ultrasound studies when the Instance Level C-FIND

for multi-frame configuration is enabled.

Corrections and Modifications

n System administrators can now add a configuration for grouping single-frame instances into a

single group per instance when the Instance Level C-FIND for multi-frame configuration is

enabled. (RESMDHTML-7024)

Release 6.2.1

2018/02/23

The 6.2.1 maintenance release incorporates one of the fixes packaged into the 6.0.2p5 patch.

Corrections and Modifications

n Fixed a threading issue which, in rare instances, was causing the viewer to not display

thumbnails or images when using an EnhancedRepository. (RMD-23478).

n Mademinor updates to the user guides for a partner brand, includingmanufacturer and

trademarks information, and UDI codes. (RTD-617, RTD-618, RTD-650, RTD-651, RTD-652)

Release 6.2

2017/11/03

Release 6.2 of the ResolutionMD product has new features that are driven by the industry’s demands

in the enterprise imaging space.

New in this Release

Client Updates

All clients:

Page 32: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)32

n Added the ability to configure non-DICOM caching, including which file types are cached and

how long these cached data sets are retained.

n Added support for DICOM Supplement 119, for faster thumbnail retrieval. The server

administrator can configure this feature per repository.

n Added support for DICOMRESTful WADO-RS thumbnail retrieval, to support faster thumbnail

retrieval from Standard and Enhanced repository types.

n Added support for Multiframe Instance Level C-FIND in order to improvemultiframe loading

performance. The server administrator can configure this feature per repository.

n Improved the audit messages of non-DICOM data sets and standardized them with the

messages logged when loading DICOM data sets.

n It is now possible to adjust the brightness and contrast of RGB images via theWindow Level

(W/L) interface.

n Internet Explorer scroll direction is now consistent with other browsers.

n Improved performance of the display of the related studies list.

n Added support for Turkish for the client user interface. The interface now displays in Turkish if

the browser language is configured to this language.

HTML5 client:

n The HTML5 client is now validated for use on Android mobile devices (exceptions: PDF reports

and Audio/Visual functionality during collaboration are NOT supported). Please see the list of

validated devices under Supported and Compatible Components.

n New option to choose between patient-centric and study-centric search:

n Study-centric is existing search behavior prior to 6.2 and this remains the default.

n  Patient-centric search behavior is new to 6.2 and:

n Provides ability to search for a list of patients using a PDQ query or a C-FIND.

n Queries a XDS registry for the list of documents.

n Queries the XDS repository to retrieve the non-DICOM documents (JPEG, TIFF,

MPEG4, MPEG2, BMP, PDF, TXT, HTML, AVI, PNG).

n Configurable 2D capture - the server administrator can now configure the visibility of the

Secondary Capture Tool in the HTML5 client.

n Color-coded repositories - added the ability for the server administrator to configure a colored

indicator that will be associated with the specific repository. The colored indicator is displayed in

Page 33: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)33

the user interface, under the Selecting Repositories list, and beside the repository name in the

search results after a successful query.

iOS clients:

n Improved iOS session storage for enhanced collaboration with participants running an HTML5

client.

n Added support for iOS 11.

Security and Administration Features and Updates

n Administrators can now configure if they want All Images on or off.

n Administrators can set the default value for the Date field to any of the following: Any, 1 Day, 3

Days, 1 Week, 1 Month or 6 Months.

n Administrator can configure grouping policy for multiframe SOP classes. The default behavior is

to group all single frame instances. This can be configured per repository, to ungroup specific

SOP classes with single frame instances.

n Updated the hardware and scalability specifications. See the ResolutionMD Server

Recommendations & Minimum Hardware Requirements document for more information.

n Updated the iOS version of Tokbox to 2.12.0. All other clients pull the live Tokbox version.

n Updated the regulatory agency configuration page. For a list of the updated regulatory agencies

refer to the Regulatory updates section.

n Updated to the latest release of Java 8, to incorporate the latest security patches.

n It is not possible to view PDFs on HTML5mobile client running on an Android device; this has

been purposely removed to prevent patient data being downloaded to the mobile device.

n Updated the PureWeb library to 4.3.2, to take advantage of many security improvements,

including:

n Enhanced security: The versions of JQuery, logback, Tomcat, Spring Framework and

Spring Security used by the PureWeb server have been upgraded, to ensure that they are

up-to-date with the latest security patches.

n Codemodifications weremade to correct cross-site scripting (XSS) vulnerabilities; in

particular to prevent error messages from exposing non-generic information.

n The versions of the ICU library (for Unicode support) and libjpeg-turbo library (for JPEG

compression) have been upgraded, to ensure that they are up-to-date with the latest

security patches.

Page 34: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)34

Regulatory Updates

n Added Russian, Malaysia and Saudi Arabia regulatory clearances.

n Updated the list of countries in the Regulatory Agency configuration page and grouped them

under the following regions: Americas, Oceania, EMEA, and Other. Added a setting for

countries that do not regulate software as medical devices. Note: If upgrading from previous

versions it is recommended to review the regulatory setting following the upgrade.

n The user guides for Australia, Europe, and Canada contain the new unified "Indications for Use"

statement to reflect their updated device registrations. The unified IFU statement is the same as

the previously implemented USA FDA statement.

n The HTML5 user guide for Australia, Europe, and Canada is now a single document that

replaces the Desktop and Touchscreen guides.

Standards Updates

n Expanded DICOMmodality support to benefit more departments throughout the hospital. The

new DICOM features and SOP support include:

n Added support for DICOM data sets with palette color photometric interpretation; this

makes it possible to properly display DEXA reports and US modalities.

n Added support for DICOM data sets with YBR 422 photometric interpretation.

n Advanced repository improvements: C-FIND query parameters can now be limited to

SOPInstanceUID only, rather than the default of InstanceNumber and

SOPClassUID. The server administrator can configure this setting per repository.

n Additional repository improvements to re-use DICOM associations per repository.

Mobile Devices Updates

n The validatedmobile devices list has been expanded to include SamsungGalaxy S8.

n Android HTML5 viewer was validated on the SamsungGalaxy S5, SamsungGalaxy S7,

SamsungGalaxy S8, SamsungGalaxy Tab 2 10.1, SamsungGalaxy Tab S and the Samsung

Galaxy Tab S2.

GPU Updates

n No updates to the validated GPU cards list. See the ResolutionMD Server Recommendations &

Minimum Hardware Requirements document for up-to-date GPU support information.

Page 35: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)35

Documentation Updates

User Guides:

n Improved the structure to ensure content is consistent for all clients.

n Updated the content to reflect new features added in 6.2.

n Updated the Unique Device Identification (UDI) codes for traceability.

Service Manual and Other Server-Side Documentation:

n Added sections in the ServiceManual to include the configuration steps for the new features

added in 6.2, along with some general improvements.

n Updated the content of the ResolutionMD Server Recommendations & Minimum Hardware

Requirements document to reflect current support for 6.2.

Corrections and Modifications

Issues reported from the field

n Non-DICOMMPEG-2 files would not load. They will load now, but have an AVI icon. (RMD-

23199, Zendesk ticket: 8287)

n Thumbnails were not being retrieved if NumberOfSeriesRelatedInstances was empty or

zero for an EnhancedDicomRepostiory type. (RMD-22836, Zendesk Ticket: 8001)

n The patient list wasn't populating properly when specific patient information was not returned in

the C-FIND-RSP. (RMD-22962, Zendesk Ticket: 6740)

n High levels of CPU usage were noticed in Internet Explorer 10 and Internet Explorer 11. (RMD-

22821, Zendesk Ticket: 7395)

n XA multiframe data sets were loading with unexpected pixel aspect ratios. (RMD-22689,

Zendesk Ticket: 7688)

n Addressed amemory leak affecting Internet Explorer 11. (RESMDHTML-6238, Zendesk: 7903)

n The iOS native app would not scroll through a series after switching from split view with linked

scrolling enabled. (RMDIOS-547, Zendesk Ticket: 6838)

n The iOS native app was not able to authenticate a user if the password contained a curly brace.

(RMDIOS-518, Zendesk Ticket: 7304)

n The server would return an internal error: Cannot claim ownership of a busy

process ImageViewer. (RMD-22766, Zendesk Ticket: 7273)

Page 36: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)36

n Interrupting the data loading process would result in unexpected behavior in the Flex client.

(RMD-22517; RMD-21840; RMD-20122, Zendesk Ticket: 5966)

n The Date Within and Date Range query parameters would return unexpected results when

querying the Synapse VNA. (RESMDHTML-5744, Zendesk Ticket: 7932)

n When running the HTML5 client in Internet Explorer 11, the scrolling direction was inverted.

(RESMDHTML-2177, Zendesk Ticket: 7742)

n The referring physician namewould be displayed with delimiters when integrating with the

McKesson Cardiology Report Repository. (RMD-22387, Zendesk Ticket: 7577)

n An error message would briefly appear when navigating away from the Image Viewer on the

HTML5 client. (RESMDHTML-6256, Zendesk Ticket: 7687)

n Related studies queries, when starting with a non-DICOM data set, would not return all of the

related non-DICOM studies. (RMD-21541, Zendesk Ticket: 7164)

n The date range search criteria dates specified by the user were not being used when querying an

AVA Non-DICOM repository. (RMD-22681, Zendesk Ticket: 7965)

Issues discovered and fixed internally

n The study time value would not parse correctly when querying data sets from the Synapse VNA.

(RMD-22687)

n The thumbnail radial indicator, used to indicate loading progress for BMP reports fromMcKesson

Cardiology Report Repository, was not displaying properly. (RMD-22139)

n Addressed an issue with URL launching with a single parameter, DicomRepository, on the

iOS native app. (RMDIOS-616)

n When collaborating non-DICOM data sets on the Flex client, if the host closed the non-DICOM

data set, the study wouldn't get cleared from the client. (RMDIOS-588, RMD-22712)

n At times, the iOS native app would stop working when hosting a collaboration session with a

participant on the HTML5 viewer. (RMDIOS-583)

n Logmessages were being logged incorrectly in the pureweb.log and error.log files. (RMD-23243)

n Loading JPEG-LS or JPEG2000 thumbnails would not display. (RMD-23185)

n Addressed an issue loading NM data sets with palette-color photometric interpretation. (RMD-

23112)

n Fixed a race condition that from time to time would cause the host client to stop working when

closing collaboration sessions. (RMD-23033)

Page 37: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)37

n Queries were failing on Synapse VNA when searching using a date range that contained only the

start date or end date. (RMD-22810)

n Auto-related studies queries were not being triggered when loading a report into the Image

Viewer. (RMD-22753)

n Changing the window/level value by double tapping a touchscreen device would impact other

participants' interactivity. (RMD-22682)

n Changing the default URL launch client configuration would also change the restricted URL

launch configuration. (RMD-22674)

n In the Flex client, the ModalitiesInStudy URL launch parameter would fail to load. (RMD-

22641)

n Auto-related studies were not being triggered by XA and NM. (RMD-22473)

n When displaying reports from theMcKesson Cardiology Report Repository, reports with

unexpected date formats were not added to the worklist. (RMD-22423)

n When collaborating between the iOS native app and the HTML5 client, selecting the

measurement tool on the iOS host native app would not properly update the toolbar on the

HTML5 participant client. (RMD-22333)

n The number of series images was being displayed correctly in the Flex client if the

NumberOfSeriesRelatedInstances DICOM tag was empty. (RMD-22284)

n When loading unsupported data types in the Flex client, themost recently viewed non-DICOM

image would be displayed in the Image Viewer. (RMD-22283)

n When hosting a collaboration session on a non-DICOM data set from the iOS native app, an

HTML5 participant would occasionally not able to see the shared non-DICOM data set. (RMD-

22145)

n When loading a BMP report on the HTML5 client by dragging and dropping the data sets from the

search results panel, the client would load and then unload the data set from the Image Viewer.

(RMD-22137)

n In multi-monitor scenarios, sometimes the twomonitors would not be synchronized when

launching a second window while a study is already in the worklist, or when closing a study from

the worklist. (RMD-22131, RESMDHTML-6115)

n In the Flex client, if each individual series was loaded before the All Images stack, the All Images

stack would sometimes not contain all series in the study. (RMD-21849)

Page 38: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)38

n The radial progress indicator for BMP reports wouldn't display/update properly on the HTML5

client. (RESMDHTML-6141)

n Loading data in the HTML5 client into a 2x2 layout by double clicking would sometimes result in a

'Load Failed' error. (RESMDHTML-6113)

n Launching the iOS native app would not work properly if the URL contains an invalid repository.

(RMDIOS-568)

n The iOS native app was not updating to reflect configuration changes in themodalities list.

(RMDIOS-549)

n When sharing non-DICOM images in a collaboration session on the iOS native app, the image

would reduce in size each time the user switched between single and split view. (RMDIOS-522)

n When collaborating with an HTML5 participant from the iOS native app, themeasurement toolbar

was not disabled when the HTML5 participant selected the annotation tool. (RMD-22587)

n When linked scrolling was enabled, but only one series is loaded into a 1x2 or 2x1 layout, the

user was unable to scroll through the series. (RMD-21793)

n When hosting a collaboration session on the HTML5 client, if a Flex client participant changed

the presets using hotkeys, the presets menu on the HTML5 client would not update. (RMD-

21775)

n Specific-branded login pages were not displayed in the correct language (the language selected

in the user’s web browser language setting). (RMD-21028)

n When loading a study into amulti-layout on the HTML5 client, if the first series was a PDF report,

no series in the study would load into the Image Viewer. (RESMDHTML-6128)

n The thumbnail radial indicator color was always not updating or displaying properly.

(RESMDHTML-6008, RESMDHTML-6000, RESMDHTML-6135)

n When changing layouts or view mode on the HTML5would cause the Cinemenu selection to not

be updated properly. (RESMDHTML-5949)

n When a participant on the iOS native app joined a collaboration session, the HTML5 host would

be unable to use the slab thickness tool. (RESMDHTML-5895)

n Addressed an issue with the formats in the Date search fields. (RESMDHTML-5746)

n Copying and pasting Japanese characters in annotations did not work as expected in the HTML5

client. (RESMDHTML-5145)

n Addressed an issue when collaborating with a host usingmulti-monitor and an iOS participant

enables the slab thickness tool. (RESMDHTML-5136)

Page 39: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)39

n In HTML5 clients, dragging and dropping reports from the search results or worklist into the

Image Viewer would cause issues. (RESMDHTML-5107)

Known Issues

The following were identified as known issues in Release 6.2.

n When using Russian, Turkish or Japanese character keyboards, the hotkeys for the orientation

labels may not work properly. (RTD-528)

n Using the Cine function with very large (2000+ slices) data sets on Internet Explorer 11 will fail if

the browser memory exceeds 1.5 GB. If using Cine with large data sets is a required workflow,

the recommended workaround is to reduce the size of the Image Viewer window.

(RESMDHTML-5995)

n The Vietnamese user guide will not display when running the HTML5 viewer onGoogle Chrome.

The is a workaround for this issue, please contact CSI support for more information. (RTD-583)

n The "Unsupported Data" message no longer appears on iOS native app when viewing BMP

images. (RMDIOS-686)

n Multitenancy does not support patient-centric searching and XDS integration. (RMD-23245)

n When upgrading, the configured searchablemodalities aremigrated following the upgrade;

however, newly supportedmodalities will not be included in the configuration file and will need to

be addedmanually. (RMD-23308)

n When upgrading from 4.3.2 to 6.2.0, if a regulatory agency previously supported in 4.3.2 is

configured (such as KFDA, PMDA), the regulatory agency setting will not upgrade properly to

6.2.0. The recommended workaround is to configure the regulatory agency as Demo prior to

running the upgrade. (RMD-23226)

n For collaboration sessions hosted on the HTML5 viewer in Safari, in order for participant on the

iOS native app to be able to join, the server needs to be SSL encrypted. (RMD-23194)

n When using the HTML5 viewer on an Android device, the double tap and drag gestures to change

the window/level setting are sometimes unresponsive. (RMD-23193)

n For collaboration sessions hosted on the HTML5 viewer on an Android device, if the participant

selects a 3D preset, the host does not see which preset has been selected from the preset

menu. (RMD-23178)

Page 40: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)40

n When launching the product on HTML5 viewer in an iOS mobile device, if you clear the web

browser cache, when a second URL link is launched the user may be prompted to provide login

credentials. (RMD-23165)

n If a SOP class, such as CT orMR, which contains a large number of images in a series, is added

to be ungrouped and it results in over 400 thumbnails, the HTML5will not handle this well. (RMD-

23032)

n On Flex clients, the Date Time field is returned as empty when retrieving non-DICOM data from

the Synapse VNA. (RMD-22744)

n The iOS native app does not log out of the server when the connection times out. (RMD-21675)

n In the Android native app, when joining a collaboration hosted on an iOS native app, from time to

time the cursor seen on the host does not appear in the same location for both devices. (RMD-

5550)

n When configuring an XDS integration, if an XDS connection has been added as an integration,

the server administrator must set the display_error_dialog parameter in the

configuration.xml file to true. Otherwise, if the HTML5 viewer is still running in study-centric GUI,

an error message will be displayed to the user. (RESMDHTML-6402)

n While running the HTML5 viewer on a touchscreen device, when collaborating while the

host/participant is interacting with the viewer, the user on the HTML5 viewer can still

pan/zoom/use scrub bar. (RESMDHTML-6372)

Release 6.1.1

2017/09/26

The 6.1.1 maintenance release is a targeted release to address an urgent site escalation.

This release is intended to be released in the US ONLY. The Regulatory Agency can ONLY be set to

United States (FDA). This release is English language ONLY.

Corrections and Modifications

n Addressed an issue with related studies, where the server would not retrieve and display all

related non-DICOM studies. The issue would only occur if the user started with a non-DICOM

dataset then performed a query for related studies. (RESMDHTML-6316)

n Fixed an issue where filtering query results from the Synapse VNA using the Date Within and

Date Range search options would not apply the user-specified filters. (RESMDHTML-6300).

Page 41: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)41

Release 6.1

2017/06/26

This release is intended to be released in the US ONLY. The Regulatory Agency can ONLY be set to

United States (FDA). This release is English language ONLY.

New in this Release

Client Updates

All clients:

n Improvements made for integrating the ResolutionMD server with Epic Haiku/Canto or other iOS

apps. When integrating ResolutionMD with Epic Haiku/Canto the server administrator can

specify the client to be used during URL launch from the EPIC mobile apps, bypassing the

mobile landing pages. The client parameter accepts the following values: mobile, flex, html. If the

client parameter is not specified in the URL, the server will redirect the end-user as it did in

ResolutionMD 6.0.

HTML5 client:

n Save to PACS support. User can now create Secondary Capture (SC) DICOM objects and save

the SC dataset on the PACS. Compatible in 2D, 3D andMIP/MPR viewingmodes.

n Support for bidirectional sorting. User can sort the search results on the HTML client by Name,

PatientID, Study Date or Modality.

n Improved the UI to display non-DICOM documents in theWorklist to be sorted by Creation Date

and Time.

HTML5, iOS and Flex clients:

n Support for Cobb anglemeasurements.

n Support for Manual Synchronized Slice Scrolling. User can now link DICOM series loaded into a

1x2, 2x1 or 2x2 layout by slice number. User can load 2, 3 or 4 series into viewports, manually

align the slices in each viewport to the same anatomy, select themanual synchronized icon and

have all viewports increase/decrease by the same amount. When the extent of a series is

reached that series will not increment any further and display the last slice within the series. This

is required whenmodalities don’t have a slice position DICOM parameter specified.

Page 42: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)42

HTML5 and Flex clients:

n Support for double click/tap to 1x1 view and back. User can double click (or tap, depending on

the device) to quickly navigate from amultiple layout (1x2, 2x1, 2x2) to a 1x1 viewport and back.

The active viewport they are currently reviewing will be the series that is displayed in the 1x1

viewport. In MPR, double click/tap in the large viewport will change the layout to a 1x1 of the

large view only.

Security and Administration Features and Updates

n Hardware and Scalability Specifications updates, see the ResolutionMD Server

Recommendations & Minimum Hardware Requirements document.

n VMConfiguration is now available on ESXi versions that support Hardware Version 10.

Hardware Version 10 is available on ESXi 5.5 and 6.0.

n Updated iOS version of Tokbox to 2.10. All other clients pull the live Tokbox version.

Standards Updates

Expanded DICOMmodality support to benefit more departments throughout the hospital. New

DICOM SOP support, including support for CSPS DICOM SOP class (1.2.840.10008.5.1.4.1.1.11.2)

Mobile Devices Updates

The validated mobile devices list has been expanded to include: iPhone 7, iPhone 7 Plus, iPad Pro

(9.7")

GPU Updates

The validated GPU cards list has been expanded to include: M4000, M6000 (Linux only), M10 (Linux

only), M60

Corrections and Modifications

n iOS Mobile Client only: Modified the SecureURL launchingmechanism to accept the URL

parameter resmds://, rather than just the https:// call, in support of launching the iOS mobile

client from Epic Haiku and Cantomobile applications. (RMDIOS-21985)

n Addressed problem in the 6.1.0 release candidate 1 (RC1) that only occurred when viewing a

non-DICOM dataset on the HTML5 viewer combined with the double click/tap to 1x1 feature and

viewingmultiple patients. At times incorrect patient information was being displayed.

(RESMDHTML-6057)

Page 43: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)43

n Repackaged iOS application using Xcode 8 and Swift 3 to properly support iOS10, addressing

the issue of special characters in passwords seen when launching the product using a URL from

an iOS device. (RMDIOS-383)

n Increased the font size for all annotations making them easier to read/use. (RMD-20761)

n Addressed an issue with the server crashing when the Interactive Quality value is set outside of

minimum JPEGQuality andmaximum JPEGQuality range. If an end-user specifies a value for

Interactive Quality below theminimum JPEGQuality, theminimum JPEGQuality value will be

used. If an end-user specifies a value for Interactive Quality above themaximum JPEGQuality

value, themaximum JPEGQuality value will be used. (RMD-20373)

n Updated all AngleMeasurements to use the degree symbol "°" instead of the word "degree".

(RMD-20993)

n Addressed a collaboration issue. When hosting a collaboration session from the iOS or Android

nativemobile client the collaboration host at times can see an incorrect Patient name instead of

multiple patients, when the collaboration participant switches to layouts. (RMD-21454)

n When a server administrator is adding/configuring a Non-DICOM connection, if the server

administrator uses aWhitespace character in Connection Name, the configuration cannot be

saved and a warningmessage is displayed to the server administrator. (RMD-20502)

n When a server administrator is adding/configuringMutual SSL for a FHIR Diagnostic Report

Repository, the keystore file name and password were being autofilled with browser login

credentials. This issue has been addressed. (RMD-19981)

n Addressed aminor issue with Multi-Monitor. If an end-user performs a search and then spawns a

ChildWindow, the search results list will display 'No Studies Returned' instead of the proper

search results. (RESMDHTML-5501)

n When attempting an unbounded search using a URLwith the Restricted URL feature enabled,

the end-user should receive amessage indicated that unbounded searches are not permitted and

the search form cannot be interacted with. However the Restricted URL configuration wasn’t

being honored and the search form was available to the end-user. This issue has been

addressed. (RESMDHTML-5500)

n Addressed an issue with the Tool bar not being updated properly after ameasurement is deleted

or a different annotation type is selected on the HTML5 client. This issue has been addressed.

(RESMDHTML-4918)

Page 44: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)44

n Addressed an issue with the iOS nativemobile client. When the server administrator

enables/configures Audio Video conferencing for collaboration, the iOS client was crashing for

iOS version 10.2. This issue has been addressed. (RMDIOS-414)

n Addressed aminor issue with the Collaboration Launch Page for iOS 9 and iOS 10 devices

looking different. The iOS 9 launch page is now being used for both iOS versions. (RMDIOS-350)

n Added proper end-user information (end-user username and client IP) to the audit logs when an

end-user loads a DICOM dataset that contains a report. (RMD-21534)

n Addressed an issue with Collaboration. When the servers is configured behind a load balancer,

the Collaboration Participant was not being redirected to the appropriate collaboration session

and unable to log in. This issue has been addressed. (RMD-21502)

Known Issues

The following were identified as known issues in Release 6.1.

n When interrupting a loading process, the end-user may experience a load failure as the loading

process is not always cancelled properly. (RMD-21772)

n Android | Backwards compatibility | In order to connect a 6.1.0 nativemobile client to a 4.3.2

server using an Android client (device OS: 5.1.1 or 6.0.0) the TLS protocol/ciphers must be

updated to TLS 1.2. (RMD-21744)

n The Related Studies Search will only return one non-DICOM related studies. (RMD-21541)

n SomeGSPS datamay not be properly sent or provided by certain PACS. (RESMDHTML-5229)

n Collaboration | Android | Participant's cursor location does not match touch location. (RMD-

20670)

n iOS | Backwards compatibility | ResMD 6.1 and 6.0 iOS client is not able to activate the AV

button when hitting an older 5.3.2 server. (RMDIOS-528)

n Server | Upgrade from 4.3.2 to 6.1.0must have a configuration.xml file installed on the 4.3.2

server in order for the upgrade to succeed. (RMD-21738)

n Drag and drop is not supported for Encapsulated PDF’s, the user must double click on the report

to visualize the report properly. (RESMDHTML-5856)

Release 6.0.2p5

2017/12/08

Page 45: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)45

The 6.0.2p5 patch is a targeted patch to address urgent site escalations. This patch can only be

applied on 6.0.2, 6.0.2p1, 6.0.2p2, 6.0.2p3 or 6.0.2p4 installations by following the patch installations

instructions (Linux or Windows).

A new Knowledge Base article has been created to document how the patch can be applied and

configured.

Corrections and Modifications

n Fixed a threading issue which, in rare instances, was causing the viewer to not display

thumbnails or images when using an EnhancedRepository. (RMD-23478)

n When running the server on a 2D VM, it would sometimes throw an unexpected exception to

the image viewer. The application would not start properly and the end user would see a

"concurrent user" error. (RMD-23660).

Release 6.0.2p4

2017/09/30

The 6.0.2p4 patch is a targeted patch to address urgent site escalations. This patch can only be

applied on 6.0.2, 6.0.2p1, 6.0.2p2, or 6.0.2p3 installations by following the patch installations

instructions (Linux or Windows).

Corrections and Modifications

n Server administrators can now configure the grouping of images by SOP Class UID within a

series in the worklist. By default, the server will display single frame, multiframes, and single

image series as grouped into one scrollable image stack. (RMD-22927)

Release 6.0.2p3

2017/08/30

The 6.0.2p3 patch is a targeted patch to address urgent site escalations. This patch can only be

applied on 6.0.2, 6.0.2p1, or 6.0.2p2 installations by following the patch installations instructions

(Linux or Windows).

Page 46: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)46

Corrections and Modifications

n Fixed amemory leak associated with stopping and starting cine when running in Internet

Explorer 11. (RESMDHTML-6195)

n Added the option for the server administrator to enable/disable the All Image Stack option in the

Flex client and the HTML5 viewer. (RESMDHTML-6210, RMD-22632)

n  Added the option for the server administrator to configure thumbnail retrieval using RESTful

DICOMWADO-RS. (RMD-22461)

n  Added the option for the server administrator to configure a default date span time option in the

Flex client and the HTML5 viewer. (RMD-22732)

n Improved performance when querying and retrieving related studies. (RMD-22484)

n Ungrouped the Retired Ultrasoundmultiframe/single frame and Secondary Capture DICOM

objects. (RMD-22518, RMD-22652)

n Fixed the initial display of Secondary Capture objects inside of mixed series (multiframe and

nonmultiframe); it no longer appears zoomed in. (RMD-22515)

n Fixed an issue where double clicking a study selected in search results wouldn't expand it in the

worklist. (RMD-22807)

n Improved performance when serially requesting/retrieving the Patient ImageMetadata List from

the VA mobile framework. (AVA-555)

Release 6.0.2p2

2017/07/20

The 6.0.2p2 patch is a targeted patch to address urgent site escalations. This patch can only be

applied on 6.0.2 or 6.0.2p1 installations by following the patch installations instructions (Linux or

Windows).

Corrections and Modifications

n McKesson CPACS Reports/Non-DICOM Integration: Increased support for integrating with

McKesson CPACS to include the following workflows:

Page 47: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)47

n HTML5 Viewer only: support for querying, retrieving and displaying BMP files. (RMD-

21755)

n HTML5 Viewer and Flex Client: support for querying, retrieving and displaying PDF

reports. (RMD-21747)

n DICOMmulti-frame thumbnails and data labels in the HTML5 Viewer: Addressed someminor

issues when displaying the information (series description and image/frame numbers) in the

study list:

n When displayingmulti-frame stacks, the instance number is now displayed in the

information in the study list. (RMD-21892)

n When displaying NM DICOM studies, once the user has selected a series to view, the

series description in the study list is updated. (RMD-21980)

n When displaying US Stress Echo studies, once a series is loaded into the image viewer,

the series description in the study list will be updated to include the Image Comments (if

the DICOM tag is present), the stage name and view number (if these DICOM tags are

present) and the number of frames in each instance is displayed in the study list. (RMD-

22378, RMD-21889)

n When displaying US DICOM series, all instances will be displayed with a separate

thumbnail (including single frame datasets and Secondary Captures) and once a series is

loaded into the image viewer the number of frames in each instance is displayed in the

study list. (RESMDHTML-6004)

n When displaying XA DICOM series, all instances will be displayed with a separate

thumbnail (including single frame datasets and Secondary Captures) and once a series is

loaded into the image viewer the number of frames in each instance is displayed in the

study list. (RMD-22369)

n Networking and performance issues:

n Modified how IOD lookups are being used in order to improve performance when loading

large (2000+ image) datasets. (RMD-22321)

n Modified some appstate usage in order to reduce the processing demands in web

browsers in order to reduce load across the web-socket. (RMD-22313)

n Added ability to enable/disable using InstanceNumber DICOM tag as amatching tag

when querying for thumbnails from theMcKesson Radiology PACS in order to improve

performance. (RMD-22335)

n Added support for controlling the brightness and contrast for RGB DICOM images. (RMD-21931)

Page 48: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)48

Release 6.0.2p1

2017/05/31

Corrections and Modifications

n Load Failures: Interrupting the current series being loaded would sometimes result in a load

failure. This was observed in the following use cases:

n Users load a study, then select the All Images load. Before it completes, they select

another series to load. (RMD-21717)

n Users would start to load one study then, before the study is loaded, select a new study to

load. (RMD-21724)

n Users would start to load a study, select one series to load then, then just as that study is

completing its load, select another series to load. (RESMDHTML-5887)

n Network Errors: Network errors were occurring during interaction with the slice-slider in HTML5

client (Scrub Bar).

n Queen's | Server | 2D CPU Rendering and Physical Server | Segmentation faults when

scrolling on the slider bar. The issue was resolved by implementing a throttling interval on

the HTML client. (RMD-21787)

n Server administrators can configure the throttle interval for the slice-slider to tune its

responsiveness. Unless there are problems with the default setting, it is recommended

that the default value be kept. The throttle interval value is configured in the

studybrowser.xml file. (RESMDHTML-5874)

n High CPU usage: A fix was implemented to address high CPU usage andmemory increases,

observed particularly in web clients running on Internet Explorer 10. (RESMDHTML-5899)

Release 6.0.2

2017/02/24

New in this Release

n Configurable launch protocol: AVA administrators can now configure the launch protocol so

that it is possible to launch into Safari.

Page 49: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)49

Release 6.0.1

2017/02/07

New in this Release

n Support for integrating with an NSX Load Balancer. There is a configuration article on the CSI

Knowledge Base providing detailed steps on how to accomplish this (see

http://support.calgaryscientific.com/).

n Improved Japanese translations.

Corrections and Modifications

n Addressed an issue with PR overlay annotations. (Issue #20516)

n Addressed amulti-tenancy issue. (Issue #20486)

n Updated to version 121 of Java 1.8, to address some security vulnerabilities. Refer to the CSI

Knowledge Base (http://support.calgaryscientific.com/) for instructions on updating Java 1.8 as

new releases are available. (Issue #20411, 20678)

n Fix addressing issue playing non-DICOM videos on iOS 10.2. (Issue #20668)

Release 6.0

2016/12/20

New in this Release

Client Updates

HTML5 Improvements

n Multi-monitor desktop support. User can now support 2D and Reports on onemonitor and 2D,

Reports, MIP/MPR or 3D on the other monitor. Search results and Study List are synchronized

across monitors, series support linking scrolling and reference lines across monitors.

Collaboration in multi-monitor will share themonitor to the participant that collaboration was

started on.

n Automatic search for related studies once the end user loads the study into the Viewer.

Page 50: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)50

n Precision loupe tool brings the iOS mobile measurements to HTML5. This feature facilitates

placingmeasurements and annotations on touchscreen devices.

n Support for text annotations with precision loupe

n 2D lens tool

n Invert window/level

n Reset button onmain toolbar

n CurvedMPR menu

n Date Range search

n Thick slab rendering in MIP/MPR

n 3D Clipping planes

n Active tooltips on the client UI

n Hotkey Guide

n Default URL Launch client is now HTML5

iOS Improvements

n Accession Number in iOS

n Improved Dictation user interface

n Non-DICOM iOS10 video support

HTML5 and iOS Improvements

n Customizable image study sharing options for easy integration with 3rd-party systems, such as

Image Exchange or Reporting products

Improvements to All Clients

n Support for display of Image Laterality

n 3D Volumewill now fill the viewport on initial load

n URL launch with StudyInstanceUID is now available for non-DICOM

Security and Administration Features and Updates

n Hardware and Scalability Specifications updates

n Platform is now supported on RHEL 6.8

n VMConfiguration is now available on ESXi 6.0

Page 51: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)51

n Java version is now Java 8 64-bit for all platforms

n Dcmtk version has been upgraded to 3.6.1

n New configuration option to automatically launching related studies (HTML5 only)

n New configuration to disable host’s ability to share patient content during Collaboration

n Improved Audio/Video integration with no complex port setup

n New configuration to filter series, and unsupported SOPs and disable load errors associated with

C-MOVE sub-operations

n New configuration to re-use DICOM Associations that help improve performance for PACS with

slow C-FIND-RSP

n New configuration in EnhancedDICOMRepository to use the C-MOVE-RSP instance counts

rather than the C-FIND-RSP counts

n Improved configuration for Data Connections which brings together the setup of DICOM, non-

DICOM andReport repositories

n Code improvements to support various VeraCode security measures

n DICOM in-memory caching to improve performance of image/thumbnail loading and reducing the

number of C-MOVEs performed between the PACS and the server for a specified time.

Regulatory Updates

n The “ValidatedMobile Devices” message will be displayed to the end-user the first time they

launch the HTML5ResolutionMD client on their mobile device.

n New clearances for Taiwan and Costa Rica

n The FDA user guides contain the new Indications for Use statement as cleared by a

recent 510(k).

n HTML5 FDA guide is now a single guide that covers Desktop and Touchscreen

Standards Updates

n Support for Fast Healthcare Interoperability Resources (FHIR) to provide access to load FHIR

Diagnostic Reports

n Expanded DICOMmodality support to benefit more departments throughout the hospital. New

DICOM SOP support, including: IO, XC, RTImage, OPT, Encapsulated PDF support for type

DOC, Secondary capture support for Multiframe Single Bit, MultiframeGrayscale Byte andWord

andMultiframe True Color

Page 52: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)52

Corrections and Modifications

n When using the blacklist feature, the server will now handle when the instance number is not set.

(Issue #20438)

n Fix security issue to address cross site scripting error. (Issue #20409)

n Modified the Report Headers to use DICOM tag (0008, 0090), the Requesting Physician in the

Ordering Physician field of the report. (Issue #13023)

n Modified the Report Headers to use DICOM tag (0008, 1040), the Institutional Department Name

in the Primary Location field of the report. (Issue #13024)

n The server will display amessage to the user when a PDF can't be loaded if the web browser’s

native PDF reader is unavailable or not installed. (Issue #4871)

n Collaboration with amobile participant may fail when run using a load balancer. (RMD-17497)

n In HTML5 on iOS, reports cannot be scrolled. (RESMDHTML-2048)

n In HTML5 on iOS, when a second video is played, user is unable to exit video. (RESMDHTML-

2050)

n If multiple users load the same study at the exact same time, a rendering error may occur when

using DICOMCaching. (RMD-14734)

n Related studies results are now sorted chronologically in iOS and HTML5. (RESMDHTML-4631,

RMDIOS-349)

n Handle PatientName differences between DICOM study and instance level. (RESMDHTML-

2714)

n Closing a study from the studylist in HTML5will remove all images from the viewer.

(RESMDHTML-4803)

n Sorting search results by dates now sorts by Date and Time. (RESMDHTML-4656)

n Studies with multiple reports and no images are properly displayed. (RESMDHTML-5053)

n Collaboration participants views now properly fill the screen. (RESMHTML-2494)

n IE11 search results will now perform well with large query results. (RESMDHTML-1917)

n iOS 10 NativeMobile App and HTML5will now play non-DICOM video. (RMD-20207)

Known Issues

The following were identified as known issues in Release 6.0.

Page 53: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)53

n Themeasurement loupe is disabled when a collaboration participant using an iOS device joins a

collaboration session hosted on a desktop device. (RESMDHTML-4956)

n If an end-user continuously performs wide-open wildcard, the child window can end up in a “hung”

state and can get out of sync with the primary windows. The end-user can recover from this state

by logging out of and back into the server. (RESMDHTML-4467)

n When using the HTML5 client frommobile Safari, if an end-user minimizes the applications to

work with another program and doesn’t return to the ResolutionMD application before the client

activity timeout, the end-user will be presented with a Connection to the imaging session was

lost due to a network error message. Once the end-user dismisses this message they will be

logged out and all current work will be lost. (RMD-17412)

n While using the HTML5 client from amobile device running iOS 10, if the end user open new tabs

windows onMobile Safari, the end-user may be presented with the Network Connection error

message. Upon dismissing the error the end user will need to log back into the server and all

current work will be lost. (RMD-20252)

n When using theMulti-monitor feature with a Firefox web browser, the pop-up blocker must be

disabled. When trying to reload a previously savedmulti-monitor setup and the pop-up blocker is

initially enabled, when the end-user disables the pop-up blocker, two windows will open up

instead of just one. (RESMDHTML-4323)

n When the an end-user, using theMulti-monitor feature on IE 11, and the child window is

maximized on the secondmonitor, if the end-user closes and reopens the child window, IE 11

may not resize/reposition child window properly. (RESMDHTML-4324)

n Metadata and orientation label becomes massive when data is loaded via drag-and-drop while a

child window was already spawned. Resize the window to correct the display. (RESMDHTML-

4750)

n WhenURL launching to a report into the Flex or HTML5 client, the associated patient study will

load into the StudyList, however the end-user will need to select the report to load the report into

amodal window. (RMD-17357)

n When aURL containing the parameter, action=viewstudy is launched, and restricted URL

launchmode is configured, the search panel will still be enabled and the end-user will be able to

search for additional patient studies. (RESMDHTML-4715)

n In 3D mode, when a text annotation is placed, the text box does not appear. The text annotation

has to be selected again to open the text box. (RESMDHTML-5041)

Page 54: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)54

n In 3D mode, when a text annotation is placed, the text box does not appear. The text annotation

has to be selected again to open the text box. (RESMDHTML-5113)

n When doing a secure URL launch using the accession number as the query parameter, the

viewer will generate a redirect URLs to retrieve any additional reports, series and thumbnails.

These redirects calls, results in displaying the StudyInstanceUID and the SeriesInstanceUID

values in plain text in the logs files and when using the Network console of the web browser

developer tools. (RMD-20059)

n Multi-monitor performance is far superior on the Chrome and Firefox web browsers. Multi-monitor

performance on IE 11 is slower and not recommended at this time. (RESMDHTML-4914)

n When collaborating on a non-DICOM dataset, from time to time the dataset may appear panned

or zoomed. Resetting the view resolves this issue. (RESMDHTML-4924)

n When collaborating on a non-DICOM dataset, the participant won’t see themetadata. Only the

collaboration host will see themetadata. (RMD-20142)

n Cannot get to get to MIP/MPR (or 3D) view after closing a study inMIP/MPR or 3D.

(RESMDHTML-4987)

n When the an end-user, using theMulti-monitor feature on IE 11, dragging and dropping a dataset

from the Study List into the ImageViewer, while the server is currently trying to load a large

dataset, may result in the client to become unresponsive. The end-user can recover from this

state by reloaded the page. (RESMDHTML-5055)

n The logback.xml syslog appender fails when addingmore then one log file to the log file

appendedmessages won’t include the log filenamewhere themessage was generated from.

Redirecting the audit.log to an external logs server will still work, but when adding a second log

file, pureweb.log for example, appendedmessage won’t add themessage with the filename

appended. (RMD-20324)

n When loading the same patient datasets from different PACS connections, certain metadata

tags may not update appropriately, notably the date/time tag. (RMD-20284)

n When loading two studies, that have the same StudyInstanceUID from two different PACS, only

the first dataset will load. The second study will be displayed in the search results but the end-

user won’t be able load the study into the ImageViewer. (RMDIOS-354)

n When an end-user uses themeasurement loupe tool to measure or annotate a 3D image on the

iOS client, they won’t be able to rotate the study and add ameasure or annotation.

(RESMDHTML-4946)

Page 55: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)55

n When an end-user uses performs on unbounded search on IE 11 and the search returns a large

amount of data, the activity spinner will freezes, however the requested datasets will be returned

to the search results. (RESMDHTML-4980)

n When an end-user joins a collaboration using an iOS device, the participant won’t be able to add

text annotations. (RMDIOS-336)

n Once a collaboration session hosted from an Android client and the participant has added some

measurement, once the collaboration session is closed the Android client will remain in

measurement mode. (RMD-20321)

n Repeatedly dragging and dropping images and videos into amulti-view layout in the Flex client

can cause the Flex client to crash. This will only happen when alternating between images and

videos and only after a number of the end-user loads a number of images/videos. (RMD-20302)

n Race conditionmay exist on iOS client between loading the thumbnail and loading the dataset.

This issuemay cause network connection failures. (Issue# RMDIOS-141)

n If multiple clients attempt to load the same datasets “simultaneously”, one of the end-user’s

requests will fail to load. (Issue# RMD-19299)

n Whenmultiple studies are loaded, and Linked Scrolling enabled, a series with KO dataset may

cause scrolling in other series. (Issue# RMD-19296)

n When the server is placed under extremely heavy processor loads, the server may drop al

network connections. (Issue# RMD-18956)

n The end-user is not notified if the datasets only gets partially loaded due to an loading error.

(Issue# RMD-18925)

n HTML5 and iOS clients do not properly warn end-users if they attempt to load unsupported

DICOM dataset. (Issue# RMD-18905)

n Connection to the imaging session is intermittently lost due to a network error when using the

HTML client from iOS Mobile Safari. (Issue# RMD-17412)

n Multi-frame datasets don’t load properly in the HTML5 client. (Issue# RESMDHTML-2714)

n In Flex client, displaying the radial menu is slow on Firefox 41.0. Workaround: upgrade browser

to 42.0 or higher. (Issue# RMD-17701)

n Collaboration with amobile participant may fail when run using a load balancer. (Issue# RMD-

17497)

n On iOS during collaboration, MP4 videomay not display in set viewport for participants in split

view. (Issue# RESMDHTML-1990)

Page 56: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)56

n In HTML5 on iOS, when a second video is played, user is unable to exit video. (Issue#

RESMDHTML-2050)

n Unable to configuremandated access rules when LDAP over SSL is used. (Issue# RMD-16651)

n In collaboration, hosts and participants can become out of sync when viewing non-DICOM

images on different clients (flex/HTML5) as not all formats are supported in all clients. (Issue#

RMD-16625)

n In Flex client, Patients with the same PatientID will be grouped together. (Issue# RMD-16369)

n If multiple users load the same study at the exact same time, a rendering error may occur.

(Issue# RMD-14734)

n Images may not be removed from the viewer if studies for different Patients have the same

PatientID. (Issue# RMD-13785)

n Multiple PDF instances for any OTmodality will only show one PDF. (Issue# RMD-10987)

n Adjustingmagnification using the + and - keys during collaborationmay not reflect the same

change for all participants. (Issue# RMD-16600)

n 3D linear measurement does not work in IE 8. Workaround; Use an alternate browser. (Issue#

RMD-12351)

n The button in MIP/MPR to expand to full size in the top right of the image viewer does not work.

(Issue# RMD-11270)

n Android Devices | Crashing when returning frommultitasking only after session timeout.

Workaround; Launch application again. (Issue# RMD-11029)

n iOS and Android |When switching fromWiFi to 3G, appmay disconnect. Workaround; Login in

to application if network is disconnected. (Issue# RMD-11083)

n iOS, Android| Backwards compatibility, participants see two login screens when connecting to

an older version of the server. (Issue# RMD-11100)

n Collaboration |When host is on a web client, the participants onmobile clients may see

MIP/MPR view in different order than the host. (Issue# RMD-11073)

n iOS | Closing themodality selection view returns to the searchmenu as 'any' selected, but still

only searches with last selectedmodality. (Issue# RMD-11088)

n Loading and unloading instances of the same study frommultiple PACS may result in a blank

screen. (Issue# RMD-6121)

n Study does not update with new images after performing aMIP/MPR export or 2D screen

snapshot. (Issue# RMD-6126)

Page 57: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)57

Release 5.4.2p1

2016/11/14

New in this Patch

n Address performance issues in DICOM connectivity

n Modify Enhanced DICOM repository to add new configuration to use CMOVE-RSP

n Add ability to turn off partial loads

n Add scripting to allow partners to filter at study, series and instance level

Corrections and Modifications

n DICOM association re-use provides the ability to re-use the DICOM association and can provide

performance improvement when the DICOM Associationmanagement is slow. (Issue# 20190)

n New configuration option available to use the C-MOVE-RSP instead of CFIND- RSP to

determine the number of instanced that should be retrieved for an Enhanced DICOMRepository.

(Issue# 20208)

n New configuration is available that can be used to ignore load failures. (Issue# 20219)

n Provide ability to filter study, series and instances from the study list based on the C-FIND

response. (Issue# 20189)

n Handle invalid DICOM datamore gracefully whenmultiple padding of null bytes is found in

DICOM file. (Issue# 20267)

Release 5.4.2

2016/06/15

New in this Release

n Expanded existing Report integration to support McKesson Report systems

n Extended existing Report viewing to loadMcKesson Reports in HTML5

n Expanded existing Audit Logging to include audit trail fromMcKesson Report systems

n Code improvements to address various VeraCode security concerns

Page 58: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)58

Corrections and Modifications

n Fixed an issue addressing EPIC Integration. Integration with EPIC is functioning and the end-

user is no longer presented with a Null Pointer Exceptionmessage. (Issue# 18187)

n Suite of security tickets related to the results form the VeraCode Scan. Fixes for any issues

found during the ongoing VeraCode security scan will be incorporated in future versions. (Issue#

18017, 18019, 18020, 18021, 18387, 19097)

n Fixed an issue to properly migrate Secure URL configuration settings following a product

upgrade. (Issue# 19178)

n Fixed an issue with inconsistent tooltips in the administration configuration UI and added any

missing tooltip content. (Issue# 19123)

n Fixed an HTTP caching issue. The server will verify that the client an end-user is connecting with

is using the latest version of Flash and ensures that when an end user’s client is using the latest

version they will not be prompted to download the Flash client again. (Issue# 16852)

n Fixed an issue launching a URL from an Android device when the server is integrated behind a

Load Balancer or behind a Proxy, or when connecting to the server over ports 80 or 443. (Issue#

17521)

n Fixed an issue displaying the StudyBrowser in the Flex client when using Internet Explorer 9.

(Issue# 17560)

n Fixed an issue with the “RelatedStudyRepository” URL parameter in order to restrict any

searches for related studies to specified DICOM repositories when the product is launched using

URLs. (Issue# 18030)

n Fixed an issue with the "view" URL parameter to support the launching the client directly into the

specified view (for example, Single2D, MIPMPR, etc.). Refer to the ServiceManual for more

information. (Issue# 18031)

n Fixed an issue with Audio Video Collaboration in Internet Explorer 11. Audio Video Collaboration

is supported on the HTML5 client, on Internet Explorer 11 and on the latest Firefox. Audio Video

collaboration is supported on the latest Google Chrome if SSL is configured. (Issue# 19234)

n Fixed an issue with scrolling reports in the HTML5 client on and iOS device. (Issue #2048)

Page 59: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)59

Release 5.4

2015/11/10

New in this Release

Mitra Report Templating: ResolutionMD now supports a template engine to allow a site

administrator to configure the content displayed in the body of Mitra reports for the site. Mitra reports

can be edited, cloned and deleted. Configuration details are documented in service manual.

Regulatory Changes

n ResolutionMD is now registered with the Health Sciences Authority (HSA) in Singapore for

diagnosis using both web andmobile devices.

n ResolutionMD is now licensed by theMinistry of Food and Drug Safety (MFDS) in South Korea

for diagnosis using both web andmobile devices.

n ResolutionMD is now registered with the National Health Surveillance Agency (ANVISA) in

Brazil for diagnosis using both web andmobile devices.

n The USFDA Unique Device Identification (UDI) requirements have been implemented in the

ResolutionMD labelling.

Release 5.3.3 (iOS Client Only)

2016/07/04

Corrections and Modifications

n The iOS Titlebar will always be updated when an end-user switches between loadingmultiple

image stacks, loading another study and returning to the original multiple image stack. (Issue#

RMD-19216)

Page 60: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)60

Release 5.3.3 (Android Client Only)

2016/06/22

Corrections and Modifications

n Fixed an issue addressing backward compatibility of the pan and zoom function on the Android

client when connecting to 4.3.2 servers. (Issue# RMD-19378)

Release 5.3.2

2016/02/12

Corrections and Modifications

n The HTML client now supports viewing native PDF files loaded from the Synapse VNA by

double-clicking on the thumbnail image in the study list. Just like the DICOM Encapsulated PDF

Reports, these will be displayed in a different tab. (Issue# RMD-2138)

Release 5.3.1

2016/01/29

Corrections and Modifications

n Fixed an issue where URL launching the HTML5 client would prompt the user to “Select this

view” before loading data. (Issue# RMD-2089)

n Certain elements of the responsive design of the HTML5 client can now be configured on the

server. For example, an admin can change the threshold width of the display at which point the

Study List is shown/hidden. (Issue# RMD-2106)

n Fixed an issue where tiered archive searching was not respected when launching URLs and all

configured PACS were being queried together. (Issue# RMD-18005)

n Fixed an issue where PatientID was being sent in DICOM requests at Series and Instance

level with the wrong VR. (Issue# RMD-18051)

Page 61: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)61

n Integrations with EPIC EMR will now properly use the encid parameter for secure URL

launches. (Issue# RMD-18187)

Release 5.3

2015/11/01

New in this Release

HTML5 Client

n All images stack

n Linked scrolling

n Toggle GSPS display on/off

n Configurable search to include study description, referring physicians and date of birth

n Sort search results by Patient Name, Patient ID, Study Date andModality

n Window/level presets

n Flip/rotation

n Report printing

n Metadata display modes of auto, all, limited or none

n New context menu which replaces the right-click drop-downmenu

n Cine and scrolling performance improvements

iOS 8

n Additional updates to streamline workflow for iOS 8.

n Improvements to runmore optimized on iOS 9.

Corrections and Modifications

n Large non-DICOM files can now be opened without crashing. (RMD-14093)

n It is now possible to filter image types by SopClassUid. (RMD-17275)

n HTML5 client can now display Synapse CV reports. (RESMDHTML-1974)

n HTML5 client can now search and display OT images. (RESMDHTML-1937)

n It is now possible to perform fine scrolling on iPhone and iPad. (RESMDHTML-1957)

Page 62: ResolutionMD Release Notes · ResolutionMD®6.4ReleaseNotes ConfidentialandProprietary ©2012-2019CalgaryScientificInc.(PureWeb) 3 Release6.0 49 Release5.4.2p1 57 Release5.4.2 57

ResolutionMD® 6.4Release Notes

Confidential and Proprietary

© 2012-2019 Calgary Scientific Inc. (PureWeb)62

n Participants see confidential information when joining on an iOS host. (RMD-16855)

n Using the Flex client on Internet Explorer 9 no longer requires Internet Explorer compatibility

mode to be set. (RMD-17560)

n When the ResolutionMD server is configured to use a load balancer it will no longer show an

unable to connect server message. (RMD-17521)

n Server will no longer contact audio/video service if audio/video is not configured. (Issue# RMD-

16866)

n During a partial load, the iOS client will now allow new data to be loaded. (RMD-17572)

n The EnhancedDicomRepository configuration will no longer request the thumbnail instance level

query. (RMD-16027)

n jQuery has be updated to remove potential security risk. (RMD-16295)

n OnAndroid, during a partial load, the client will now display metadata. (RMD-15994)

n Non-DICOM repositories can now be configured usingmulti-tenancy. (RMD-16241)

n HTML5 client now supports server clustering. (RMD-16585/RESMDHTML-1952)

n Rotation on an iPad will be locked while loading data. Rotating the iPad while loading data in split