Mini-Rester Mini-Rester Residential Water Hammer Arrester All Mini-Resters are approved for sealed wall installations with no access panel required May be installed at any angle AA size Seamless, cold rolled and spin closed Pressurized air cushion Dual o-ring piston Listed by UPC/IAPMO to meet UPC-2006 Conforms to IPC-2006 Certified by ASSE to the ANSI/ASSE 1010-2004 Standard

Upload: jumasonic

Post on 09-Nov-2015

39 views

Category:

Documents


2 download

DESCRIPTION

Hammer arrester

TRANSCRIPT

  • Mini-ResterMini-ResterResidential Water Hammer Arrester

    All Mini-Resters are approved for sealed wall installations with no access panel required

    May be installed at any angle

    AA size

    Seamless, cold rolled and spin closed

    Pressurized air cushion

    Dual o-ring piston

    Listed by UPC/IAPMOto meet UPC-2006

    Conforms to IPC-2006

    Certied by ASSE to the ANSI/ASSE 1010-2004

    Standard

  • Both major National Model Codes require water hammer control in all residential and commercial water supply sys-tems. Since 1997, both the Uniform Plumbing Code (UPC) sponsored by the International Association of Plumbing and Mechanical Ofcials (IAPMO) and the International Plumb-ing Code (IPC) sponsored by

    the International Code Coun-cil (ICC) have required water hammer control on all quick-closing valves. The AA arrester (Mini-Rester) is by far the most common approved device that satises these codes. Plain air chambers do NOT satisfy the requirements of either code. Many states across the coun-try are now enforcing these

    arrester requirements, while many more are in the process of doing the same. With the Mini-Rester, code ofcials now realize proper water hammer control is permanent, afford-able, and very feasible, even for residential applications.

    Although water hammer is a subject usually left up to plumbing engineers, the ef-fects of water hammer must be dealt with every day by plumb-ing contractors everywhere. Water hammer is easily recog-nized by the banging or thump-ing noise thats heard when valves are shut off. Although this is an easy way to recognize

    the problem, water hammer doesnt always make these telltale noises. Water hammer occurs when the ow of mov-ing water is suddenly stopped by a closing valve. This sudden stop results in a tremendous spike of pressure behind the valve which acts like a tiny ex-plosion inside the pipe. This pressure spike reverberates

    throughout the plumbing sys-tem, rattling and shaking pipes, until it is absorbed. Normally, a sufcient pocket of air will ab-sorb such a pressure spike, but if no pocket of air is present, expensive xtures and appli-ances within the plumbing sys-tem will be damaged as they are left to absorb this pressure spike.

    Why Air Chambers Dont Work

    It used to be thought that an air chamber, or capped stand pipe, was an effective solution to controlling water hammer. However, within an air cham-ber, nothing separates the air from the water. It only takes a few short weeks before the air is absorbed into the water, leaving the air chamber water-logged and completely ineffec-

    tive. Laboratory tests conrm that the air is depleted by sim-ple air permeation and by in-teraction between static pres-sure and ow pressure. In the diagram shown, (right) notice the difference in water level between static line pressure and post-cycle static level.

    The most effective means of controlling water hammer is a measured, compressible cush-ion of air which is permanently separated from the water sys-tem. Sioux Chief arresters em-ploy a pressurized cushion of air and a two o-ring piston, which permanently separates this air cushion from the water system. When the valve closes and the

    water ow is suddenly stopped, the pressure spike pushes the piston up the arrester cham-ber against the pressurized cushion of air. The air cushion in the arrester reacts instantly, absorbing the pressure spike that causes water hammer. Al-though arresters are typically tested to 10,000 cycles, Sioux Chief arresters have been in-

    dependently lab tested to with-stand 500,000 cycles without failure. All Sioux Chief arrest-ers are guaranteed to control water hammer for the lifetime of the plumbing system.For more information about water hammer control, see our Engineer Report or Water Hammer FAQ. Call or visit our web site to request a copy.

    Controlling Water Hammer

    What is Water Hammer?

    National Model Codes

  • Residential Installation Guide

    Well Connected

    SweatStraight and Tees

    F1960 PEX, F1807 PEX, F2080 PEXStraight (F1807 PEX only) and Tees

    CompressionStraight and Tees

    CPVCMale and Female

    MIPStraight

    Toilet BallcockTee

    Washing Machine Supply Stop" or " Female Comp.

    Tub/Shower Valvefor Sweat, PEX, or CPVC

    Specications

    Maximum Working Temp

    250F

    Maximum Working Pressure for Pressure Testing

    350 PSIG

    Burst Tested 2,900 PSIG

    Fixture Unit Value 4

    Ice Maker660-TC0B

    Tub/Shower Valve660-TS

    Toilet Ballcock660-TKB

    Lav/Sink Supply660-TR1B

    Dishwasher660-TR1B

    Washing Machine660-HB

    Code Compliance

    As Needed

    Recommended

    2006 Uniform Plumbing Code (UPC/IAPMO)609.10 Water Hammer: All building water supply systems in which quick-acting valves are installed shall be provided with devices to absorb the hammer caused by high pressures resulting from the quick closing of these valves. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices shall be installed as close as possible to quick-acting valves.609.10.1 Mechanical Devices: When listed mechanical devices are used, the manufacturers specications as to location and method of installation shall be followed.

    2006 International Plumbing Code (IPC)604.9 Water hammer: The ow velocity of the water distribution system shall be controlled to reduce the possibility of water hammer. A water-hammer arrestor shall be installed where quick-closing valves are utilized. Water-hammer arrestors shall be installed in accordance with the manufacturers specications. Water-hammer arrestors shall conform to ASSE 1010.

  • DISTRIBUTED BY

    24110 South Peculiar DrivePeculiar, Missouri 64078tel: 1-800-821-3944fax: 1-800-758-5950www.siouxchief.com

    Mini-Rester

    Bar-Coded Clamshells in a Cut Case Box

    Item No. Description Min. Qty. Case Qty.

    List Price

    STRAIGHT660-SB " male sweat 50 50 12.25 EA

    660-3SB " male sweat 50 50 16.25 EA660-CB " O.D. compression straight 50 50 15.10 EA660-2B " MIP thread 50 50 12.80 EA

    660-V2B " female CPVC 50 50 14.90 EA660-V82B " male CPVC 50 50 12.25 EA660-X2B " PEX crimp straight 50 50 12.95 EA

    TEE660-T22 " full-slip female sweat tee 25 25 15.50 EA660-HB " female swivel hose thread " male hose thread tee 25 25 15.65 EA660-TKB Female swivel ballcock nut male ballcock thread tee 25 25 19.95 EA

    TUB/SHOWER VALVE660-TS " male sweat open end branch " female sweat tee 25 25 18.50 EA

    660-TSF7 " FIP swivel " female sweat tee 25 25 21.25 EA660-TSV7 " FIP swivel " CPVC tee 25 25 21.75 EA660-TSX7 " FIP swivel " PEX F1807 crimp tee 25 25 20.75 EA660-TSX " male sweat " PEX F1807 crimp tee 25 25 22.50 EA

    PEX TEE*660-TW2 " PEX cold expansion tee F1960 25 25 17.95 EA660-TX1B " PEX crimp tee F1807 25 25 17.25 EA660-TX2B " PEX crimp tee F1807 25 25 15.95 EA660-TA2B " PEX cold expansion tee F2080 25 25 18.95 EA

    COMPRESSION TEE660-TC0B " O.D. compression tee for ice maker tube 25 25 17.25 EA 660-TC1B " O.D. compression tee for supply tube 25 25 17.75 EA660-TC2B " O.D. compression tee for " O.D. dishwasher tube 25 25 18.00 EA

    660-TB " O.D. compression tee for " nom. copper tube 25 25 17.85 EAFEMALE COMPRESSION TEE

    660-TR1B " O.D. comp. " O.D. female compression 25 25 17.25 EA660-TR2B " O.D. comp. " O.D. female compression 25 25 18.25 EA660-TRB " O.D. comp. " O.D. female compression 25 25 17.65 EA

    Item No. Description Min. Qty. Case Qty.

    List Price

    STRAIGHT660-S " male sweat 6 6 13.75 EA660-C " O.D. compression straight 6 6 16.60 EA660-2 " MIP thread 6 6 14.30 EA

    660-V82 " male CPVC 6 6 14.40 EATEE

    660-H " female swivel hose thread " male hose thread tee 6 6 17.15 EA660-TK Female swivel ballcock nut male ballcock thread tee 6 6 21.45 EA

    PEX TEE*660-TX1 " PEX crimp tee F1807 6 6 18.75 EA660-TX2 " PEX crimp tee F1807 6 6 17.45 EA

    COMPRESSION TEE660-TC0 " O.D. compression tee for ice maker tube 6 6 18.75 EA660-TC1 " O.D. compression tee for supply tube 6 6 19.25 EA660-TC2 " O.D. compression tee for " O.D. dishwasher tube 6 6 19.50 EA

    660-T " O.D. compression tee for " nom. copper tube 6 6 19.35 EAFEMALE COMPRESSION TEE

    660-TR1 " O.D. comp. " O.D. female compression 6 6 18.75 EA660-TR2 " O.D. comp. " O.D. female compression 6 6 19.75 EA660-TR " O.D. comp. " O.D. female compression 6 6 19.15 EA

    Bulk Packaging

    MINI-RESTER BROCHURE 2/07 2007 SIOUX CHIEF MANUFACTURING

    *Note on ASTM PEX Fitting Standards:ASTM F1807: PEX Barb Insert Fittings Utilizing a Copper Crimp

    Ring.ASTM F1960: PEX Cold Expansion Fittings Utilizing a PEX

    Compression RingASTM F2080: PEX Cold Expansion Fittings Utilizing a Metal

    Compression Ring